Plumbing_2nd_Floor.pdf

PDF 430 KB Posted

Attached to
Treasury OFAC Renovation Federal contract opportunity
Solicitation number
2032H319R00008
Issued by
Department of the Treasury Internal Revenue Service

About this file

Plumbing 2nd Floor

View the file

Other files for this federal contract opportunity

Other files attached to Treasury OFAC Renovation, newest first.
File Type Posted
2032H319R00008_005.pdf PDF
Wage_Determination_DC2_-_072619.pdf PDF
Plumbing_3rd_Floor.pdf PDF
2032H319R00008_004.pdf PDF
Attachment_C_-2nd_Floor_Pricing_Worksheet_RR.xlsx XLSX spreadsheet
2032H319R00008_0003.pdf PDF
2032H319R00008_0002.pdf PDF
2032H319R00008_-_0001.pdf PDF
Site_Visit_List.pdf PDF
Sign_Type_A1.pdf PDF
Security_&_Secured_Window_Package_3rd_Fl.pdf PDF
3rd_Floor_RFP_v1.pdf PDF
2nd_Floor_RFP.pdf PDF
2nd_Floor_100__DRAWING_4-4-2019_S300R.pdf PDF
3rd_floor_April_28_2019_100__Full_Set.pdf PDF
Attachment_B_-3rd_floor_LAN_room_Cable_Tray_Layout.pdf PDF
3rd_Floor_Annex_100__SPEC.pdf PDF
2nd_and_3rd_Floor_Furniture_Power_&_Data_Changes.pdf PDF
Attachment_A_-_2nd_floor_LAN_room_layout.pdf PDF
Treasury_Annex_2nd_Floor_ET101_Revised.pdf PDF
Attachment_B_-_2nd_floor_LAN_room_cable_tray_layout.pdf PDF
1_-_2032H319R00008-OFAC_RENOVATION_7-9-19.pdf PDF
Attachment_C_-2nd_Floor_Pricing_Worksheet_RR.xlsx XLSX spreadsheet
Sketch_of_X010_Lock.pdf PDF
drawing_A106_-_Security_&_Secured_Window_Package_2nd_Fl.pdf PDF
Sign_Type_A2.pdf PDF
SIGN_P-Mount-Teknion.pdf PDF
SD2500_2510TechSpec.pdf PDF
Security_&_Secured_Window_Package_2nd_Fl.pdf PDF
Secure_Insert_Window_Detail.pdf PDF
Attachment_C_-_Annex_3rd_floor_Pricing_Worksheet_RR.xlsx XLSX spreadsheet
Treasury_Annex_Restrooms_Renovation_Spec.pdf PDF
2nd_Floor_Annex_100__SPEC.pdf PDF
Attachment_D_-2nd_floor_Information_Outlet_Layout.pdf PDF
Historic_Restoration_Package_dated_4.4.19.pdf PDF
Attachment_D_-_3rd_floor_Information_Outlet_layout.pdf PDF
3rd_Floor_Restroom_100__3-28-2019_R.pdf PDF
3rd_floor_-_ET-101_Revised.pdf PDF
Attachment_A_-3rd_floor_LAN_room_layout.pdf PDF
Schedule_FFB_2nd_and_3rd_Floors.xlsx XLSX spreadsheet
TRES_2nd_Floor_Restroom_100___DRAWING_3-28-2019.pdf PDF
Show all 41

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECOND FLOOR - DEMOLITION

SCALE: 1/4" = 1'-0"

P-104 P-104 N

SECOND FLOOR PLAN

SCALE: 1/4" = 1'-0"

P-104 P-104 N

GENERAL NOTES

G1. ALL WORK SHALL BE NEW AND PROVIDED UNDER THIS CONTRACT UNLESS

SPECIFICALLY MARKED EXISTING, EXIST., OR (E).

G2. VERIFY LOCATION AND DIMENSIONS OF EXISTING EQUIPMENT AND COORDINATE

ALL WORK PRIOR TO THE START OF CONSTRUCTION.

G3. COORDINATE PLUMBING PIPING LOCATION WITH ELECTRICAL PANELS AND

EQUIPMENT. PIPING SHALL NOT CROSS OVER PANELS. REFER TO

ELECTRICAL DRAWINGS.

G4. COORDINATE PLUMBING PIPING WITH MECHANICAL EQUIPMENT, PIPING

AND DUCTWORK. REFER TO MECHANICAL DRAWINGS.

G5. FIRESTOP ALL PENETRATIONS THROUGH RATED WALLS AND FLOORS.

G6. PROVIDE ISOLATION VALVES IN ACCESSIBLE LOCATION.

NOTES

1. REMOVE FIXTURE, SUPPORTS, ASSOCIATED PIPING, VALVES AND

APPURTENANCES COMPLETE TO POINTS INDICATED AT WALLS AND FLOORS.

CAP HW PIPE IN WALL FOR FIXTURES WITH HW CONNECTIONS.

2. REMOVE FIXTURE, SUPPORTS, ASSOCIATED PIPING, VALVES AND

APPURTENANCES COMPLETE TO POINTS INDICATED.

3. REMOVE FIXTURE, SUPPORTS, ASSOCIATED PIPING, VALVES AND

APPURTENANCES COMPLETE TO POINTS INDICATED. CAP PIPES IN WALLS AND

BELOW FLOORS AS INDICATED.

4. REMOVE PIPING, VALVES, SUPPORTS AND APPURTENANCES COMPLETE TO

POINTS INDICATED.

5. PROVIDE 1/2" COLD WATER TAP IN CABINETRY BELOW SINK FOR

REFRIGERATOR. PROVIDE 1/2" SHUTOFF VALVE AND A WATTS SERIES LF7R

BACKFLOW PREVENTOR.

6. INDICATED PIPING IS LOCATED BELOW FLOOR SLAB.

7. INDICATED PIPING IS LOCATED ABOVE CEILING.

8. ROUTE DOMESTIC WATER AND WASTE AND VENT PIPING IN CHASE TO SERVE

PLUMBING FIXTURES. REUSE EXISTING FLOOR PENETRATION FOR WASTE PIPE

ON FLOOR MOUNTED FIXTURES.

9. CORE DRILL EXISTING FLOOR TO ALLOW FOR PIPING PENETRATION.

10. PATCH, REPAIR AND FINISH FLOOR TO MATCH EXISTING ADJACENT SURFACES

WHERE PENETRATIONS ARE NOT BEING USED. REFER TO DETAIL 1 ON P-002.

11. PATCH, REPAIR AND FINISH WALLS UPON COMPLETION OF WORK. SEE

ARCHITECTURAL DRAWINGS FOR DETAILS.

12. PROVIDE 1/2" COLD WATER LINE BELOW FLOOR SLAB FROM TRAP PRIMER TO

FLOOR DRAIN. INSTALL TPV ON EXISTING CW LINE TO WATER CLOSETS.

13. PROVIDE MINIMUM 18"x18" ACCESS DOOR IN WALL FOR ACCESS TO WATER

HAMMER ARRESTOR AND TRAP PRIMING VALVE. COORDINATE VALVES AND

ARRESTOR LOCATION WITH ACCESS DOOR.

14. REMOVE PORTIONS OF EXISTING WALLS ON 1ST AND 2ND FLOORS TO PERFORM

WORK AS INDICATED. PATCH, REPAIR AND FINISH WALLS TO MATCH EXISTING

ADJACENT SURFACES UPON COMPLETION OF WORK.

15. PROVIDE AND RACK DOMESTIC PIPING, VALVES AND APPURTENANCES

COMPLETE ON WALL IN JANITOR'S CLOSET.

16. PROVIDE THERMOSTATIC MIXING VALVE SIZED FOR 14 GPM AND 5 PSI MAXIMUM

PRESSURE DROP. SET TO 110°F.

17. PROVIDE HEAT TRAPS WHERE INDICATED. PIPE IS TO OFFSET DOWN

ACCORDING TO DETAIL 2 ON P-002.

18. REFER TO DETAIL 2 ON P-002 AND RISERS ON P-601 FOR ADDITIONAL PIPE SIZE

INFORMATION IN THE JANITOR'S CLOSET.

N

DETAIL -

2ND FLOOR PLAN

SCALE: 1/2" = 1'-0"

P-104 P-104

P

W

P

P

W

W

P-8

P-104 P-104

C.O.

C.O.

1-1/2"TW

1/2"TWC

3/4"TW

ET-1D

DWH-1D CP-1D

P-9D

3"FL.D.

TPV

3"W

4"W

3"W 2"V4

2"V

2"V

(E)HW

(E)1-1/2"W

(E)HW&CW

(E)CW

(E)HW&CW

(E)W

(E)W

(E)4"W

(E)CW

3/4"TW

1"TW1"TW

1/2"CW

2"CW

1/2"TWC

1-1/4"TW

1-1/2"TW

1/2"TWC

1-1/2"TW

2"CW

1-1/2"CW

1/2"TWC

1-1/4"TW

7 7

10 1110 11

10 14

18 16

MEN

RM-201

WOMEN

RW-201

MEN

RM-201

WOMEN

RW-201

LAV 1

LAV 1

LAV 1

LAV1

LAV3

WC WC 11

WC WC 11

WC WC 11

WC WC 3

UR

UR1

J.S.2

P-1

P-1P-1

P-1

P-2 P-2

P-6

P-6

P-6P-6

P-6 P-4

P-3

4CAP

P

W

P

P

W

W

(E)W

(E)W

(E)4"W

(E)CW

3"FL.D.

3"FL.D.

P-7

REFRIGERATOR

3"FL.D.

TPV

3"W

1"CW &

3/4"HW

3/4"CW & 1/2"HW

F.C.O.

1-1/2"CW

1/2"HW

F.C.O.

2-1/2"V 7

1"CW

FI

LE

N

AM

E:

OU

R

RE

F:

PL

OT

D

AT

E:

8/7

/20

6:

:36 A

M

P-

4.D

W G

OF

RE

VI

SI

ON

N

OT

ES

GR

AP

HI

C

SC

AL

E

MARK DATE DESCRIPTION

CE

RT

IFI

CA

TIO

NS

SHEET SIZE:

SHEET

DISCIPLINE SHEET TYPE SEQUENCE

DRAWING NO.

DRAWING TITLE

FILE NAME

CHECKED BY

DRAWN BY DATE DRAFTED:

PROJECT NO.

GSA PM

SUB. DATE

SUBMISSION

DESCRIPTION

PROJECT

TITLE

BUILDING NOs.

OTHER

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

DR

AW

IN

G

PR

OJ

EC

T

BU

ILD

IN

G

SUB A/E

PRIME A/E

CONS. CONTR.

A/E CON. NO.

CO

NT

RA

CT

OR

S

FLOOR NO.

CONSTR. CON.

FACILITY CODE

PROJECT

A/E TASK NO.

CONS. WORK

24 x 36

DC-

2 3 4 5

2 3 4 5

A

B

C

D

DEPARTMENT OF TREASURY

1500 PENNSYLVANIA AV. NW

WASHINGTON DC 20220

BARBARA CHOATE

N/A

MERIDIEN GROUP / CITADEL DCA

SUMMER CONSULTANTS

100%

0018-10

TREASURY ANNEX BUILDING:

RESTROOM UPGRADES

29 MARCH 2019

RESTROOM UPGRADES

MERIDIEN GROUP, LLC

208 SOUTH KING ST. SUITE 303

LEESBURG, VA 20175

(703) 777-8285 www.meridiengroupllc.com

2ND FLOOR PLAN

P-104

N

4'01'2' 2' 1/2"=1'-0"

8'02'4' 4' 1/4"=1'-0"

P-104 P-104

P-104 P-104