2026 Road Maintenance Program
JOINT SEALANTS 079200 - 1
SECTION 079200 - JOINT SEALANTS
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
A. Section Includes:
1. Silicone joint sealants.
2. Nonstaining silicone joint sealants.
3. Urethane joint sealants.
4. Immersible joint sealants.
5. Silyl-terminated polyether joint sealants.
6. Mildew-resistant joint sealants.
7. Polysulfide joint sealants.
8. Butyl joint sealants.
9. Latex joint sealants.
B. Related Requirements:
1. Section 321216 "Asphalt Paving" for sealing joints between concrete and asphalt pavement.
2. Section 321373 "Concrete Paving Joint Sealants" for sealing joints in paved roads, parking lots, walkways, and curbing.
1.3 ACTION SUBMITTALS
A. Product Data: For each joint-sealant product.
B. Sustainable Design Submittals:
C. Samples for Initial Selection: Manufacturer's color charts consisting of strips of cured sealants showing the full range of colors available for each product exposed to view.
D. Samples for Verification: For each kind and color of joint sealant required, provide Samples with joint sealants in 1/2-inch- wide joints formed between two 6-inch-long strips of material matching the appearance of exposed surfaces adjacent to joint sealants.
E. Joint-Sealant Schedule: Include the following information:
1. Joint-sealant application, joint location, and designation.
2. Joint-sealant manufacturer and product name.
3. Joint-sealant formulation.
JOINT SEALANTS 079200 - 2
4. Joint-sealant color.
1.4 INFORMATIONAL SUBMITTALS
A. Qualification Data: For qualified testing agency.
B. Preconstruction Laboratory Test Schedule: Include the following information for each joint sealant and substrate material to be tested:
1. Joint-sealant location and designation.
2. Manufacturer and product name.
3. Type of substrate material.
4. Proposed test.
5. Number of samples required.
C. Preconstruction Laboratory Test Reports: From sealant manufacturer, indicating the following:
1. Materials forming joint substrates and joint-sealant backings have been tested for compatibility and adhesion with joint sealants.
2. Interpretation of test results and written recommendations for primers and substrate preparation are needed for adhesion.
D. Preconstruction Field-Adhesion-Test Reports: Indicate which sealants and joint preparation methods resulted in optimum adhesion to joint substrates based on testing specified in "Preconstruction Testing" Article.
E. Field-Adhesion-Test Reports: For each sealant application tested.
F. Sample Warranties: For special warranties.
1.5 QUALITY ASSURANCE
A. Installer Qualifications: An authorized representative who is trained and approved by manufacturer.
B. Product Testing: Test joint sealants using a qualified testing agency.
1. Testing Agency Qualifications: Qualified according to ASTM C 1021 to conduct the testing indicated.
1.6 FIELD CONDITIONS
A. Do not proceed with installation of joint sealants under the following conditions:
1. When ambient and substrate temperature conditions are outside limits permitted by joint-sealant manufacturer.
2. When joint substrates are wet.
3. Where joint widths are less than those allowed by joint-sealant manufacturer for applications indicated.
JOINT SEALANTS 079200 - 3
4. Where contaminants capable of interfering with adhesion have not yet been removed from joint substrates.
1.7 WARRANTY
A. Special Installer's Warranty: Installer agrees to repair or replace joint sealants that do not comply with performance and other requirements specified in this Section within specified warranty period.
1. Warranty Period: 2 years from date of Substantial Completion.
B. Special Manufacturer's Warranty: Manufacturer agrees to furnish joint sealants to repair or replace those joint sealants that do not comply with performance and other requirements specified in this Section within specified warranty period.
1. Warranty Period: 2 years from date of Substantial Completion.
C. Special warranties specified in this article exclude deterioration or failure of joint sealants from the following:
1. Movement of the structure caused by stresses on the sealant exceeding sealant manufacturer's written specifications for sealant elongation and compression.
2. Disintegration of joint substrates from causes exceeding design specifications.
3. Mechanical damage caused by individuals, tools, or other outside agents.
4. Changes in sealant appearance caused by accumulation of dirt or other atmospheric contaminants.
PART 2 - PRODUCTS
2.1 JOINT SEALANTS, GENERAL
A. Compatibility: Provide joint sealants, backings, and other related materials that are compatible with one another and with joint substrates under conditions of service and application, as demonstrated by joint-sealant manufacturer, based on testing and field experience.
2.2 URETHANE JOINT SEALANTS
A. Urethane, S, P, 35, T, NT: Single-component, pourable, plus 35 percent and minus 35 percent movement capability, traffic- and nontraffic-use, urethane joint sealant; ASTM C 920, Type S, Grade P, Class 35, Uses T and NT.
2.3 JOINT-SEALANT BACKING
A. Sealant Backing Material, General: Nonstaining; compatible with joint substrates, sealants, primers, and other joint fillers; and approved for applications indicated by sealant manufacturer based on field experience and laboratory testing.
JOINT SEALANTS 079200 - 4
B. Cylindrical Sealant Backings: ASTM C 1330, , and of size and density to control sealant depth and otherwise contribute to producing optimum sealant performance.
2.4 MISCELLANEOUS MATERIALS
A. Primer: Material recommended by joint-sealant manufacturer where required for adhesion of sealant to joint substrates indicated, as determined from preconstruction joint-sealant-substrate tests and field tests.
B. Cleaners for Nonporous Surfaces: Chemical cleaners acceptable to manufacturers of sealants and sealant backing materials, free of oily residues or other substances capable of staining or harming joint substrates and adjacent nonporous surfaces in any way, and formulated to promote optimum adhesion of sealants to joint substrates.
C. Masking Tape: Nonstaining, nonabsorbent material compatible with joint sealants and surfaces adjacent to joints.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine joints indicated to receive joint sealants, with Installer present, for compliance with requirements for joint configuration, installation tolerances, and other conditions affecting performance of the Work.
B. Proceed with installation only after unsatisfactory conditions have been corrected.
3.2 PREPARATION
A. Surface Cleaning of Joints: Clean out joints immediately before installing joint sealants to comply with joint-sealant manufacturer's written instructions and the following requirements:
1. Remove all foreign material from joint substrates that could interfere with adhesion of joint sealant, including dust, paints (except for permanent, protective coatings tested and approved for sealant adhesion and compatibility by sealant manufacturer), old joint sealants, oil, grease, waterproofing, water repellents, water, surface dirt, and frost.
2. Clean porous joint substrate surfaces by brushing, grinding, mechanical abrading, or a combination of these methods to produce a clean, sound substrate capable of developing optimum bond with joint sealants. Remove loose particles remaining after cleaning operations above by vacuuming or blowing out joints with oil-free compressed air.
Porous joint substrates include the following:
a. Concrete.
b. Masonry.
3. Remove laitance and form-release agents from concrete.
JOINT SEALANTS 079200 - 5
3.3 INSTALLATION OF JOINT SEALANTS
A. General: Comply with joint-sealant manufacturer's written installation instructions for products and applications indicated, unless more stringent requirements apply.
B. Sealant Installation Standard: Comply with recommendations in ASTM C 1193 for use of joint sealants as applicable to materials, applications, and conditions indicated.
C. Install sealant backings of kind indicated to support sealants during application and at position required to produce cross-sectional shapes and depths of installed sealants relative to joint widths that allow optimum sealant movement capability.
1. Do not leave gaps between ends of sealant backings.
2. Do not stretch, twist, puncture, or tear sealant backings.
3. Remove absorbent sealant backings that have become wet before sealant application, and replace them with dry materials.
D. Install bond-breaker tape behind sealants where sealant backings are not used between sealants and backs of joints.
E. Install sealants using proven techniques that comply with the following and at the same time backings are installed:
1. Place sealants so they directly contact and fully wet joint substrates.
2. Completely fill recesses in each joint configuration.
3. Produce uniform, cross-sectional shapes and depths relative to joint widths that allow optimum sealant movement capability.
3.4 FIELD QUALITY CONTROL
A. Field-Adhesion Testing: Field test joint-sealant adhesion to joint substrates as follows:
1. Test Method: Test joint sealants according to Method A, Field-Applied Sealant Joint Hand Pull Tab, in Appendix X1 in ASTM C 1193 or Method A, Tail Procedure, in
ASTM C 1521.
a. For joints with dissimilar substrates, verify adhesion to each substrate separately;
extend cut along one side, verifying adhesion to opposite side. Repeat procedure for opposite side.
2. Inspect tested joints and report on the following:
a. Whether sealants filled joint cavities and are free of voids.
b. Whether sealant dimensions and configurations comply with specified requirements.
c. Whether sealants in joints connected to pulled-out portion failed to adhere to joint substrates or tore cohesively. Include data on pull distance used to test each kind of product and joint substrate. Compare these results to determine if adhesion complies with sealant manufacturer's field-adhesion hand-pull test criteria.
JOINT SEALANTS 079200 - 6
3. Record test results in a field-adhesion-test log. Include dates when sealants were installed, names of persons who installed sealants, test dates, test locations, whether joints were primed, adhesion results and percent elongations, sealant material, sealant configuration, and sealant dimensions.
4. Repair sealants pulled from test area by applying new sealants following same procedures used originally to seal joints. Ensure that original sealant surfaces are clean and that new sealant contacts original sealant.
B. Evaluation of Field-Adhesion-Test Results: Sealants not evidencing adhesive failure from testing or noncompliance with other indicated requirements will be considered satisfactory.
Remove sealants that fail to adhere to joint substrates during testing or to comply with other requirements. Retest failed applications until test results prove sealants comply with indicated requirements.
3.5 CLEANING
A. Clean off excess sealant or sealant smears adjacent to joints as the Work progresses by methods and with cleaning materials approved in writing by manufacturers of joint sealants and of products in which joints occur.
3.6 PROTECTION
A. Protect joint sealants during and after curing period from contact with contaminating substances and from damage resulting from construction operations or other causes so sealants are without deterioration or damage at time of Substantial Completion. If, despite such protection, damage or deterioration occurs, cut out, remove, and repair damaged or deteriorated joint sealants immediately so installations with repaired areas are indistinguishable from original work.
3.7 JOINT-SEALANT SCHEDULE
A. Joint-Sealant Application: Exterior joints in horizontal traffic surfaces.
1. Joint Locations:
a. Control and expansion joints in brick pavers.
b. Isolation and contraction joints in cast-in-place concrete slabs.
c. Joints between plant-precast architectural concrete paving units.
d. Joints in stone paving units.
e. Joints between different materials listed above.
B. Joint-Sealant Application: Interior joints in horizontal traffic surfaces.
1. Joint Locations:
a. Isolation joints in cast-in-place concrete slabs.
b. Control and expansion joints in stone flooring.
2. Joint Sealant: Urethane, S, P, 35
3. Joint-Sealant Color: Gray.
JOINT SEALANTS 079200 - 7
END OF SECTION 079200
| PART 1 - GENERAL |
| 1.1 RELATED DOCUMENTS |
| A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. |
| 1.2 SUMMARY |
| A. Section Includes: |
| 1. Silicone joint sealants. |
| 2. Nonstaining silicone joint sealants. |
| 3. Urethane joint sealants. |
| 4. Immersible joint sealants. |
| 5. Silyl-terminated polyether joint sealants. |
| 6. Mildew-resistant joint sealants. |
| 7. Polysulfide joint sealants. |
| 8. Butyl joint sealants. |
| 9. Latex joint sealants. |
| B. Related Requirements: |
| 1. Section 321216 "Asphalt Paving" for sealing joints between concrete and asphalt pavement. |
| 2. Section 321373 "Concrete Paving Joint Sealants" for sealing joints in paved roads, parking lots, walkways, and curbing. |
| 1.3 ACTION SUBMITTALS |
| A. Product Data: For each joint-sealant product. |
| B. Sustainable Design Submittals: |
| C. Samples for Initial Selection: Manufacturer's color charts consisting of strips of cured sealants showing the full range of colors available for each product exposed to view. |
| D. Samples for Verification: For each kind and color of joint sealant required, provide Samples with joint sealants in 1/2-inch- wide joints formed between two 6-inch-long strips of material matching the appearance of exposed surfaces adjacent to join... |
| E. Joint-Sealant Schedule: Include the following information: |
| 1. Joint-sealant application, joint location, and designation. |
| 2. Joint-sealant manufacturer and product name. |
| 3. Joint-sealant formulation. |
| 4. Joint-sealant color. |
| 1.4 INFORMATIONAL SUBMITTALS |
| A. Qualification Data: For qualified testing agency. |
| B. Preconstruction Laboratory Test Schedule: Include the following information for each joint sealant and substrate material to be tested: |
| 1. Joint-sealant location and designation. |
| 2. Manufacturer and product name. |
| 3. Type of substrate material. |
| 4. Proposed test. |
| 5. Number of samples required. |
| C. Preconstruction Laboratory Test Reports: From sealant manufacturer, indicating the following: |
| 1. Materials forming joint substrates and joint-sealant backings have been tested for compatibility and adhesion with joint sealants. |
| 2. Interpretation of test results and written recommendations for primers and substrate preparation are needed for adhesion. |
| D. Preconstruction Field-Adhesion-Test Reports: Indicate which sealants and joint preparation methods resulted in optimum adhesion to joint substrates based on testing specified in "Preconstruction Testing" Article. |
| E. Field-Adhesion-Test Reports: For each sealant application tested. |
| F. Sample Warranties: For special warranties. |
| 1.5 QUALITY ASSURANCE |
| A. Installer Qualifications: An authorized representative who is trained and approved by manufacturer. |
| B. Product Testing: Test joint sealants using a qualified testing agency. |
| 1. Testing Agency Qualifications: Qualified according to ASTM C 1021 to conduct the testing indicated. |
| 1.6 FIELD CONDITIONS |
| A. Do not proceed with installation of joint sealants under the following conditions: |
| 1. When ambient and substrate temperature conditions are outside limits permitted by joint-sealant manufacturer. |
| 2. When joint substrates are wet. |
| 3. Where joint widths are less than those allowed by joint-sealant manufacturer for applications indicated. |
| 4. Where contaminants capable of interfering with adhesion have not yet been removed from joint substrates. |
| 1.7 WARRANTY |
| A. Special Installer's Warranty: Installer agrees to repair or replace joint sealants that do not comply with performance and other requirements specified in this Section within specified warranty period. |
| 1. Warranty Period: 2 years from date of Substantial Completion. |
| B. Special Manufacturer's Warranty: Manufacturer agrees to furnish joint sealants to repair or replace those joint sealants that do not comply with performance and other requirements specified in this Section within specified warranty period. |
| 1. Warranty Period: 2 years from date of Substantial Completion. |
| C. Special warranties specified in this article exclude deterioration or failure of joint sealants from the following: |
| 1. Movement of the structure caused by stresses on the sealant exceeding sealant manufacturer's written specifications for sealant elongation and compression. |
| 2. Disintegration of joint substrates from causes exceeding design specifications. |
| 3. Mechanical damage caused by individuals, tools, or other outside agents. |
| 4. Changes in sealant appearance caused by accumulation of dirt or other atmospheric contaminants. |
| PART 2 - PRODUCTS |
| 2.1 JOINT SEALANTS, GENERAL |
| A. Compatibility: Provide joint sealants, backings, and other related materials that are compatible with one another and with joint substrates under conditions of service and application, as demonstrated by joint-sealant manufacturer, based on testing... |
| 2.2 URETHANE JOINT SEALANTS |
| A. Urethane, S, P, 35, T, NT: Single-component, pourable, plus 35 percent and minus 35 percent movement capability, traffic- and nontraffic-use, urethane joint sealant; ASTM C 920, Type S, Grade P, Class 35, Uses T and NT. |
| 2.3 JOINT-SEALANT BACKING |
| A. Sealant Backing Material, General: Nonstaining; compatible with joint substrates, sealants, primers, and other joint fillers; and approved for applications indicated by sealant manufacturer based on field experience and laboratory testing. |
| B. Cylindrical Sealant Backings: ASTM C 1330, , and of size and density to control sealant depth and otherwise contribute to producing optimum sealant performance. |
| 2.4 MISCELLANEOUS MATERIALS |
| A. Primer: Material recommended by joint-sealant manufacturer where required for adhesion of sealant to joint substrates indicated, as determined from preconstruction joint-sealant-substrate tests and field tests. |
| B. Cleaners for Nonporous Surfaces: Chemical cleaners acceptable to manufacturers of sealants and sealant backing materials, free of oily residues or other substances capable of staining or harming joint substrates and adjacent nonporous surfaces in a... |
| C. Masking Tape: Nonstaining, nonabsorbent material compatible with joint sealants and surfaces adjacent to joints. |
| PART 3 - EXECUTION |
| 3.1 EXAMINATION |
| A. Examine joints indicated to receive joint sealants, with Installer present, for compliance with requirements for joint configuration, installation tolerances, and other conditions affecting performance of the Work. |
| B. Proceed with installation only after unsatisfactory conditions have been corrected. |
| 3.2 PREPARATION |
| A. Surface Cleaning of Joints: Clean out joints immediately before installing joint sealants to comply with joint-sealant manufacturer's written instructions and the following requirements: |
| 1. Remove all foreign material from joint substrates that could interfere with adhesion of joint sealant, including dust, paints (except for permanent, protective coatings tested and approved for sealant adhesion and compatibility by sealant manufactu... |
| 2. Clean porous joint substrate surfaces by brushing, grinding, mechanical abrading, or a combination of these methods to produce a clean, sound substrate capable of developing optimum bond with joint sealants. Remove loose particles remaining after c... |
| a. Concrete. |
| b. Masonry. |
3. Remove laitance and form-release agents from concrete.
| 3.3 INSTALLATION OF JOINT SEALANTS |
| A. General: Comply with joint-sealant manufacturer's written installation instructions for products and applications indicated, unless more stringent requirements apply. |
| B. Sealant Installation Standard: Comply with recommendations in ASTM C 1193 for use of joint sealants as applicable to materials, applications, and conditions indicated. |
| C. Install sealant backings of kind indicated to support sealants during application and at position required to produce cross-sectional shapes and depths of installed sealants relative to joint widths that allow optimum sealant movement capability. |
| 1. Do not leave gaps between ends of sealant backings. |
| 2. Do not stretch, twist, puncture, or tear sealant backings. |
| 3. Remove absorbent sealant backings that have become wet before sealant application, and replace them with dry materials. |
| D. Install bond-breaker tape behind sealants where sealant backings are not used between sealants and backs of joints. |
| E. Install sealants using proven techniques that comply with the following and at the same time backings are installed: |
| 1. Place sealants so they directly contact and fully wet joint substrates. |
| 2. Completely fill recesses in each joint configuration. |
| 3. Produce uniform, cross-sectional shapes and depths relative to joint widths that allow optimum sealant movement capability. |
| 3.4 FIELD QUALITY CONTROL |
| A. Field-Adhesion Testing: Field test joint-sealant adhesion to joint substrates as follows: |
| 1. Test Method: Test joint sealants according to Method A, Field-Applied Sealant Joint Hand Pull Tab, in Appendix X1 in ASTM C 1193 or Method A, Tail Procedure, in ASTM C 1521. |
| a. For joints with dissimilar substrates, verify adhesion to each substrate separately; extend cut along one side, verifying adhesion to opposite side. Repeat procedure for opposite side. |
| 2. Inspect tested joints and report on the following: |
| a. Whether sealants filled joint cavities and are free of voids. |
| b. Whether sealant dimensions and configurations comply with specified requirements. |
| c. Whether sealants in joints connected to pulled-out portion failed to adhere to joint substrates or tore cohesively. Include data on pull distance used to test each kind of product and joint substrate. Compare these results to determine if adhesion ... |
| 3. Record test results in a field-adhesion-test log. Include dates when sealants were installed, names of persons who installed sealants, test dates, test locations, whether joints were primed, adhesion results and percent elongations, sealant materia... |
| 4. Repair sealants pulled from test area by applying new sealants following same procedures used originally to seal joints. Ensure that original sealant surfaces are clean and that new sealant contacts original sealant. |
B. Evaluation of Field-Adhesion-Test Results: Sealants not evidencing adhesive failure from testing or noncompliance with other indicated requirements will be considered satisfactory. Remove sealants that fail to adhere to joint substrates during test...
| 3.5 CLEANING |
| A. Clean off excess sealant or sealant smears adjacent to joints as the Work progresses by methods and with cleaning materials approved in writing by manufacturers of joint sealants and of products in which joints occur. |
| 3.6 PROTECTION |
| A. Protect joint sealants during and after curing period from contact with contaminating substances and from damage resulting from construction operations or other causes so sealants are without deterioration or damage at time of Substantial Completio... |
| 3.7 JOINT-SEALANT SCHEDULE |
| A. Joint-Sealant Application: Exterior joints in horizontal traffic surfaces. |
| 1. Joint Locations: |
| a. Control and expansion joints in brick pavers. |
| b. Isolation and contraction joints in cast-in-place concrete slabs. |
| c. Joints between plant-precast architectural concrete paving units. |
| d. Joints in stone paving units. |
| e. Joints between different materials listed above. |
| B. Joint-Sealant Application: Interior joints in horizontal traffic surfaces. |
| 1. Joint Locations: |
| a. Isolation joints in cast-in-place concrete slabs. |
| b. Control and expansion joints in stone flooring. |
| 2. Joint Sealant: Urethane, S, P, 35 |
| 3. Joint-Sealant Color: Gray. |