Attachment 3e - B748 Limited Hazardous Materials Survey Report.pdf
PDF 6 MB Posted
- Solicitation number
- 140P8320R0008
About this file
This Request for Proposals solicits abatement of hazardous materials including asbestos, lead, mercury, polychlorinated biphenyls, and wildlife excrement in several historic buildings at Fort Vancouver National Historic Site. The National Park Service seeks these abatement and selective demolition services along with minor building repairs. The small business set-aside requires the awardee have no more than $22 million in average annual receipts. The contractor must complete work within 180 days of award using firm-fixed-price construction contracts governed by prevailing wage requirements. A payment bond, performance bond, and proof of insurance are due prior to commencement. The estimated value ranges from $250,000 to $1 million depending on optional tasks exercised. Offerors should submit technical and price proposals through www.beta.SAM.gov by the date specified in amendments to the solicitation.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1011 SW Klickitat Way, Suite 104, Seattle, Washington 98134
Phone 206-381-1128
Toll Free 800-666-2959
Fax 206-254-4279
• Environmental Consulting
• Hazardous Materials Management
• Industrial Hygiene Services
• Construction Management
• Indoor Air Quality
LIMITED HAZARDOUS MATERIALS SURVEY REPORT
NATIONAL PARK SERVICE
FORT VANCOUVER NATIONAL HISTORIC SITE
BUILDING 748
East Vancouver Barracks Building 748
Vancouver, Washington 98661
October 31st, 2018
Prepared For:
Kristen Jontos National Park Service 612 East Reserve Street Vancouver, WA 98661 ii
Limited Hazardous Materials Survey Report
National Park Service
Fort Vancouver Historic Site
East Vancouver Barracks Building 748, Vancouver, Washington 98661
EHSI Project No.: # 11176
The material and data in this report were prepared under the supervision and direction of the undersigned.
Rory Peterson Lead AHERA Building Inspector
Derica Escamilla
Principal of Hazardous Materials Services iii
TABLE OF CONTENTS
Acronym List .............................................................................................. iv
1.0 EXECUTIVE SUMMARY
1.1 BACKGROUND
1.2 EXTENT OF CURRENT SURVEY
1.3 ACM MATERIALS FOUND
1.4 OPINIONS AND RECOMMENDATIONS
1.5 LIMITATIONS/DISCLAIMER
2.0 LIMITED LEAD AND ASBESTOS SURVEY REPORT
2.1 BACKGROUND
2.2 BUILDING DESCRIPTION
2.3 SAMPLING METHODOLOGY
2.3.1 Asbestos-Containing Materials
2.3.2 Lead-Containing Paint/Lead-Containing Materials
2.3.3 Hazardous Substance-Containing Sludge
2.4 SAMPLING RESULTS
2.4.1 Asbestos-Containing Materials
2.4.2 Lead-Containing Paint and Building Materials
2.4.3 Toxicity Characteristic Leaching Procedure Sampling
2.4.4 Polychlorinated Biphenyls
2.4.5 Mercury-Containing Fluorescent Light Tubes, CFL Bulbs, and thermostats
2.4.6 Contaminated Substance-Containing Sludge
3.0 LIMITATIONS
4.0 STANDARD OF CARE
5.0 CERTIFIED AHERA BUILDING INSPECTORS
APPENDICES
A ........................ Asbestos Laboratory Reports and Field Data Forms
B ........................ Lead Laboratory Reports and Field Data Forms C ........................ Certified AHERA Building Inspector Certificates
D ........................ Laboratory Certifications for Asbestos and Lead Analysis E ......................... Sample Location Drawings for Asbestos and Lead F ......................... Hazardous Metals TCLP Laboratory Reports and Field Data Forms
G ........................ Drain Sludge Analytical Reports and Field Data Forms iv
ACRONYM LIST
ACM .......................Asbestos-Containing Material
Ag ..........................Silver
AHERA ....................Asbestos Hazard Emergency Response Act
AHU .......................Air Handling unit
AIHA ......................American Industrial Hygiene Association
As ..........................Arsenic
Ba ..........................Barium
Cd ..........................Cadmium
CFL ........................Compact Fluorescent Light
CFR ........................Code of Federal Regulations
Cr ..........................Chromium
DOSH .....................Washington State Department of Labor and Industries, Division of
Occupational Safety and Health
EA ..........................Each
Ecology ...................Washington State Department of Ecology
EHSI .......................EHS-International, Inc.
ELLAP .....................Environmental Lead Laboratory Accreditation Program
GWB .......................Gypsum Wall Board
Hg ..........................Mercury
JC ..........................Joint Compound
LCM ........................Lead-Containing Material
LCP ........................Lead-Containing Paint
LF ..........................Linear Feet
L&I .........................Washington State Department of Labor and Industries mg/L ......................Milligrams Per Liter
N/A ........................Not Applicable
ND .........................None Detected
NVL ........................NVL Laboratories, Inc.
NVLAP ....................National Voluntary Laboratory Accreditation Program
OD .........................Outside Diameter
OSHA .....................US Occupational Safety and Health Administration
Pb ..........................Lead
PCBs .......................Polychlorinated Biphenyls
PLM ........................Polarized Light Microscopy ppm .......................Parts per Million
QA .........................Quality Assurance
RCRA ......................Resource Conservation and Recovery Act
RCW .......................Revised Code of Washington
SAT ........................Seattle Asbestos Test, LLC
Se ..........................Selenium
SF ..........................Square Feet
SVF ........................Sheet Vinyl Flooring
TCLP .......................Toxicity Characteristic Leaching Procedure
VCT ........................Vinyl Composite Tile
WAC .......................Washington Administrative Code
wt. .........................Weight w/ ..........................With
XRF ........................x-ray fluorescence
Fort Vancouver National Historic Site – B748
EHSI Project 11035
December 24th, 2018
1.0 EXECUTIVE SUMMARY
1.1 BACKGROUND
The National Park Service (NPS) plans to renovate Building 748 (B748) at the Fort Vancouver
National Historic Site (FV NHS) located at 611 Fort Vancouver Way, Vancouver, Washington.
The NPS has contracted EHS-International, Inc. (EHSI), a hazardous materials and industrial hygiene consulting firm, to conduct a Limited Lead and Asbestos Survey of B748 in preparation for this project. The intent of the survey is to specifically identify and quantify asbestos-containing building materials (ACM), interior lead-containing paint (LCP), other interior lead-containing building materials (LCM), to collect a lead toxicity characteristic leaching procedure (TCLP) sample representative of all materials that may be in the assumed waste stream, and to inspect and quantify fluorescent light fixtures that may contain polychlorinated biphenyl (PCB)-containing ballasts, and mercury (Hg)-containing fluorescent light tubes, compact fluorescent light (CFL) bulbs, and high intensity discharge (HID) lamps, that may be impacted by renovation activities. In addition, EHSI also collected sludge samples from interior and exterior drains to identify the presence of Benzene, Toluene, Ethylbenzene, and Xylenes, total petroleum hydrocarbons (TPH) as diesel and motor oil, and Resource
Conservation and Recovery Act (RCRA) metals (arsenic, barium, cadmium, chromium, lead, mercury, selenium, and silver).
1.2 EXTENT OF CURRENT SURVEY
EHSI inspected accessible interior and exterior suspect ACM that may be potentially impacted by future projects. Accessible suspect materials were sampled including, but not limited to:
interior and exterior wall systems, window systems, and mechanical systems. The LCP and
LCM survey was limited to the interior of the building only. The sludge sampling was limited to drains that were accessible and representative of the interior and exterior drainage system in and around B748. EHSI accomplished a representative destructive inspection; however, in areas inaccessible for inspection (e.g., energized electrical equipment and unit heaters) suspect materials were assumed to be ACM.
1.3 ACM MATERIALS FOUND
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
NATIONAL PARK SERVICE
FORT VANCOUVER BARRACKS – BUILDING 748
ASBESTOS MATERIAL DESCRIPTION LOCATION
Non-ACM orange/red carpet w/ non-ACM beige mastic w/ non-ACM brown burlap backing on 9”x9” maroon/ red
VAT w/ ACM black mastic on concrete
[Sample ##s 267 & 268]
Office B1 & B2
9”x9” Maroon/red VAT w/ ACM black mastic on concrete
[Sample #s 267 & 268]
Break Room
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
NATIONAL PARK SERVICE
FORT VANCOUVER BARRACKS – BUILDING 748
ASBESTOS MATERIAL DESCRIPTION LOCATION
ACM black asphaltic roofing debris w/ non-ACM black asphaltic roofing tar debris w/ non-ACM wood and paint debris (on drop ceilings)
[Sample #315QA]
Metal Shop, Break Room, Restroom, Storage 1, Parts
Storage 1, 2, & 3, and
Office 1 & 2
Small electrical panels and electrical disconnects w/ assumed ACM internal components (<1 SF in size)
Metal Shop, Break Room, Vehicle Bay, and Exterior
Electrical panels and electrical disconnects w/ assumed ACM internal components (1 SF to 5 SF in size)
Break Room and Vehicle
Bay
4’x1’6” Mirror w/ assumed ACM mastic Restroom
2’x2’x3’ Heaters w/ assumed ACM internal components, sealant, and/or insulation Vehicle Bay
KEY: ACM = asbestos containing material, OD = outer diameter, VCT = vinyl composite tile, w/ = with
1.4 OPINIONS AND RECOMMENDATIONS
EHSI recommends that all impacted ACM identified in paragraph 1.3 be removed and disposed of prior to renovation and demolition activities.
Any suspect materials not identified as having been surveyed in this report must be treated as an ACM until determined otherwise by a Certified Asbestos Building Inspector and NVLAP certified laboratory.
Washington State Department of Labor and Industries (L&I) Division of Occupational Safety and Health (DOSH) and the US Occupational Safety and Health Administration (OSHA) require employers to conduct a hazard assessment and take appropriate worker protection precautions whenever building materials are disturbed that have detectable quantities of lead. Since the type of work planned (e.g., demolition or renovation) will disturb the LCP, the contractor should perform an initial exposure assessment in accordance with the regulations. Special care should be taken to reduce potential employee exposure to lead when demolishing porcelain bathroom fixtures and painted metal, including reducing airborne dust (eq., water misting and use of hand tools, and/or local exhaust ventilation).
All fluorescent light fixtures inspected have magnetic ballasts which are assumed to contain greater than two parts per million (> 2 ppm) PCB-dielectric fluid. Magnetic ballasts must be removed from fixtures and disposed of as Washington Department of Ecology (Ecology)
Dangerous Waste. All fluorescent tubes and lamps contain mercury; any fluorescent lamps/tubes to be disturbed during the project must be recycled as (Ecology) Universal Waste.
Ecology’s Model Toxics Control Act (MTCA) (Chapter 70.105D RCW) cleanup standards and law administer cleanup and prevention of contaminated sites. A representative number of interior and exterior drain sludge was sampled and compared to MTCA Method A and Method B cleanup levels. Based on the results, the sludge and surrounding soil should be cleaned up in accordance with MTCA standards.
1.5 LIMITATIONS/DISCLAIMER
This report does not represent a comprehensive hazardous materials investigation for the subject property. This investigation has been conducted by EHSI under a specific scope of work authorized by the NPS for a specific purpose. Energized electrical equipment and unit heaters were not sampled but were assumed to be present based on the inspector’s experience with similar systems on other projects and are assumed to be ACMs. Exterior lead sampling was excluded from the scope of work. All exterior painted surfaces are assumed to have lead-containing paint. This report and accompanying appendices include the supporting information for this executive summary.
2.0 LIMITED LEAD AND ASBESTOS SURVEY REPORT
2.1 BACKGROUND
The NPS has contracted EHSI to accomplish a pre-renovation limited hazardous materials survey of the existing structure and to collect a lead-TCLP sample representative of the anticipated demolition debris. For the limited hazardous materials survey, EHSI was tasked to use applicable federal, state, and local guidelines in the accomplishment of its survey. EHSI was further tasked to provide a written survey report including: identification of all suspect materials; a determination of whether suspect materials were: ACM, LCP, and LCM, and to provide analytical reports indicating the presence and quantity of the hazardous materials.
From September 18th and 19th, 2018, EHSI conducted a Limited Hazardous Materials Survey that meets the Washington State “Good Faith Survey” requirements as cited in Revised Code of Washington (RCW) 49.26.016 and implemented by L&I DOSH regulation, Washington
Administrative Code (WAC) 296-62-07721, and Regulation Section 476-040 of the Southwest
Clean Air Agency (SWCAA).
2.2 BUILDING DESCRIPTION
Building 748 is located at the East Vancouver Barracks site in Vancouver, Washington. The building is a single-story wood-framed structure with a partial basement. The building sits on a concrete slab foundation. The building’s roof is covered with 3-tab composite shingles.
Interior floor finishes include: vinyl asbestos tile (VAT), carpet, and painted concrete floors.
Interior wall finishes include: original tongue and groove wood wall panels, and painted plywood, and gypsum wallboard. Interior ceiling finishes include: wood panels, exposed tongue and groove wood decking, texturing on gypsum wall board (GWB), and plywood.
Windows throughout the building are operable and wood-framed. Heating is provided by natural local electric base board heaters, and natural gas fired ceiling mounted unit heaters.
There is also evidence that the building was originally heated by a coal fired furnace system.
Hot water is provided by an electric domestic hot water tank. Interior lighting consists of incandescent and fluorescent ceiling fixtures and natural light from the windows.
2.3 SAMPLING METHODOLOGY
2.3.1 Asbestos-Containing Materials
The EHSI field inspectors are asbestos Building Inspectors, certified under the requirements of the United States Environmental Protection Agency (USEPA) AHERA regulation 40 Code of
Federal Regulations (CFR) 763, Subpart E. Copies of their certificates are provided in Appendix
C. The number of bulk samples collected and their locations are based on the AHERA regulation and the guidelines provided by the USEPA Document 560/5-85-030a, October
1985, Asbestos in Buildings: Simplified Sampling Scheme for Friable Surfacing Materials.
EHSI collected samples and obtained analytical data for suspect ACM identified on the property. Once collected, each bulk sample was sealed in an unadulterated plastic bag to eliminate the possibility of cross-contamination. “Chain-of-Custody” tracking was followed to maintain sample integrity during handling and data reporting at EHSI and the analytical laboratory. As specified in 40 CFR Chapter 1 (1-1-87 edition) Part 763, Subpart F, and
Appendix A, each sample was analyzed using polarized light microscopy (PLM) / dispersion staining techniques, in accordance with USEPA Method 600/R-93/116. Samples were analyzed for asbestos content by Seattle Asbestos Test, LLC (SAT) located in Seattle, Washington. SAT participates in the National Institute for Standards and Technology (NIST) National Voluntary
Laboratory Accreditation Plan (NVLAP). Only materials containing more than 1% total asbestos were classified as “asbestos-containing” based on USEPA, state, and local regulations.
Samples in the report labeled as ##QA are quality assurance (QA) samples. Split samples were taken from the same location and they were sent to separate laboratories. QA samples were submitted to, NVL Laboratories, Inc. (NVL) in Seattle, WA, another NVLAP laboratory.
Copies of both laboratories’ NVLAP certifications are included in Appendix D.
2.3.2 Lead-Containing Paint/Lead-Containing Materials
EHSI used a Niton Model XLp x-ray fluorescence (XRF) Spectrum Analyzer to measure lead content on interior paint coatings and other suspect LCM. Measurements were representative of all layers of paint and/or LCM. A summary of Lead Paint XRF results is provided in Table 3.
Bulk quality assurance samples were taken for a representative number of LBP and LCM and were sent to NVL located in Seattle, Washington, an accredited laboratory for Atomic
Absorption Spectroscopy (USEPA Method-7000B) by the American Industrial Hygiene
Association (AIHA) under the Environmental Lead Laboratory Accreditation Program (ELLAP).
Copies of laboratory reports and field data forms for lead are in Appendix B.
All XRF sample shots are representative of that color on that specific substrate and component. The report user shall deduce from the data in Table 3 and 4, if certain building materials throughout the entire building contain lead and should not assume that what is detected is only in the specific location identified in the Table.
2.3.3 Petroleum Hydrocarbon Contaminated Sludge
EHSI collected eight (8) sludge samples using three (3) volatile organic analysis (VOA) vials and one, four (4) ounce glass jar container. The VOA vials were filled using EPA 5035 – purge and trap techniques. The four-ounce jars were filled using the same method. Following collection, the filled sample containers were placed in a cooler with ice until delivery to the analytical laboratory. EHSI field personnel checked all sample containers for completeness and cap tightness. The sample cooler was then placed in a field vehicle to await transportation to Freidman and Bruya, Inc. located in Seattle, Washington, a National Environmental
Laboratory Program (NELAP) accredited laboratory for Ecology Method NWTPH-Dx, USEPA
Method 8021B, and USEPA Method 6020B. Not all samples were submitted for each analysis.
Selected samples were submitted based upon the primary contaminants of concern. A summary of the analytical results is provided in Table 7,8, and 9 and associated laboratory report is provided in Appendix G.
2.4 SAMPLING RESULTS
2.4.1 Asbestos-Containing Materials
Ninety (90) bulk samples of suspect ACM were collected as part of the survey. Six (6) of those samples were split for quality assurance analyses. Limited destructive inspection was conducted to identify hidden and/or concealed materials. Copies of the asbestos analytical laboratory results are included in Appendix A. Asbestos and lead sample location drawings are provided in Appendix E. Asbestos sampling information including: sample number, material description, sample location, and analytical results are summarized in Table 1. The
ACM and assumed ACM identified during this survey, including the quantity and location, is summarized in Table 2. Suspect materials not sampled were assumed to be ACM.
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
FORT VANCOUVER BARRACKS – BUILDING 748
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11176-266 Office 2
Layer 1: Orange/red carpet
Layer 2: Beige mastic
Layer 3: Brown burlap backing
(on 267)
ND
(All Layers)
N/A
(All Layers)
11176-267 Office 2
Layer 1: 9” x 9” Maroon/red
VAT
Layer 2: Black mastic
Layer 3: White concrete seam/expansion joint sealant
(on concrete)
L1: 2%
L2: 3%
L3: ND
Chrysotile
N/A
11176-268 Break
Room
Layer 1: 9” x 9” Maroon/red
VAT
Layer 2: Black mastic (on concrete)
L1: 2%
L2: 3%
11176-
269QA
Break Room
White/beige concrete seam/ expansion joint sealant (under
268)
ND N/A
11176-270 Restroom Layer 1: Red brick
Layer 2: Gray mortar
ND
(All Layers)
N/A
(All Layers)
11176-271 Vehicle Bay
Dark gray/brown pipe dope (on natural gas line fittings to NE heater)
ND N/A
11176-272 Vehicle Bay
Beige/dark gray pipe dope (on natural gas line fittings to SE heater)
ND N/A
11176-273 Vehicle Bay Brown/gray pipe dope (on main natural gas line fittings)
ND N/A
11176-274 Vehicle Bay
Tan pipe dope (on water line fittings visible in vehicle bay and storage room)
ND N/A
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
FORT VANCOUVER BARRACKS – BUILDING 748
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11176-275 Vehicle Bay
Reddish tan/brown pipe dope
(on visible compressed air pipe fitting)
ND N/A
11176-276 Exterior, W.
Side
Tan window glazing putty w/ paint (on 3’x3’2” wood-framed windows)
ND N/A
11176-277 Exterior, N.
Side
Tan window glazing putty w/ paint (on 3’x3’2” wood-framed windows)
ND N/A
11176-278 Exterior, N.
Side
White window glazing putty patch w/ paint (on 3’x3’2” wood-framed windows)
ND N/A
11176-279 Exterior, N.
Side
White window frame caulking w/ paint (on 3’x3’2” wood-framed windows)
ND N/A
11176-280 Exterior, E.
Side
Layer 1: White window frame caulking w/ paint
Layer 2: Yellow foam seam filler (on 3’x6’4” window systems)
ND
(All Layers)
N/A
(All Layers)
11176-
281QA
Exterior, E.
Side
Gray/light gray window glazing putty w/ paint (on 3’x6’4” window system w/ 3’x3’1” lower and 3’x3’3” upper windows, wood-framed)
ND N/A
11176-
282QA
Exterior, E.
Side
Tan window glazing putty w/ paint (on 3’x6’4” window system w/ 3’x3’1” lower and
3’x3’3” upper windows, wood-framed)
ND N/A
11176-283 Exterior, E.
Side
White window glazing putty patch w/ paint (on 3’x6’4” window system w/ 3’x3’1” lower and 3’x3’3” upper windows, wood-framed)
ND N/A
11176-284 Exterior, E.
Side
White window glazing putty patch w/ paint (on 3’x6’4” window system w/ 3’x3’1” lower and 3’x3’3” upper windows, wood-framed)
ND N/A
11176-285 Vehicle Bay
Beige/off-white window glazing putty w/ paint (on 3’x3’1” windows and 3’x3’3” clerestory windows)
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
FORT VANCOUVER BARRACKS – BUILDING 748
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11176-286 Office 1
Gray window glazing gasket
(on 6’x3’ metal-framed windows)
ND N/A
11176-287 Exterior, W.
Side
White window frame caulking w/ paint (on 6’x3’ metal-framed windows)
ND N/A
11176-288 Exterior, E.
Side
White siding caulking w/ paint
(throughout exterior)
ND N/A
11176-289 Exterior, E.
Side
White door frame caulking (on all doors)
ND N/A
11176-290 Exterior, S.
Side White concrete patch w/ paint ND N/A
11176-291 Vehicle Bay Yellow foam pipe penetration sealant
ND N/A
11176-292 Part Storage
Room
White window glazing sealant w/ paint (on new windows, infilled on south wall)
ND N/A
11176-293 Parts
Storage 3 Bare GWB wall w/ paper ND N/A
11176-294 Parts
Storage 3 Bare GWB wall w/ paper ND N/A
11176-295
Exterior, N.E. Corner, E. Side
Black sealant w/ white coating/paint (on concrete wall)
ND N/A
11176-296
Exterior, N.E. Corner, N. Side
Black sealant w/ white coating/paint (on concrete wall)
ND N/A
11176-297 Exterior, N.W. Corner
Layer 1: White coating w/ paint
Layer 2: Black sealant (on concrete wall)
ND
(All Layers)
N/A
(All Layers)
11176-298
Exterior, N.W.
Corner, W.
Side
Layer 1: White coating w/ paint
Layer 2: Black sealant (on concrete wall)
ND
(All Layers)
N/A
(All Layers)
11176-299 Exterior, N.
Side
Black sealant w/ white coating/paint (on concrete wall)
ND N/A
11176-300 Office 2
Layer 1: Spiky troweled-on texturing w/ paint
Layer 2: GWB ceiling w/ paper
(mid-ceiling)
ND
(All Layers)
(All Layers)
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
FORT VANCOUVER BARRACKS – BUILDING 748
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11176-301 Office 1
Layer 1: Spiky troweled-on texturing w/ paint
Layer 2: GWB ceiling w/ paper
(mid-ceiling)
ND
(All Layers)
N/A
(All Layers)
11176-302 Office 1
Layer 1: Spiky troweled-on texturing/JC w/ paint
Layer 2: GWB ceiling (edge)
ND
(All Layers)
N/A
(All Layers)
11176-303 Vehicle Bay, W. Wall
Layer 1: Black asphaltic coating w/ paint
Layer 2: Trace white coating/paint
Layer 3: Wood wall siding
ND
(All Layers)
N/A
(All Layers)
11176-304 Vehicle Bay, S. Wall
Layer 1: Black asphaltic coating w/ paint
Layer 2: Trace white coating/paint
Layer 3: Wood wall siding
ND
(All Layers)
N/A
(All Layers)
11176-305 Vehicle Bay, E. Wall
Black asphaltic coating w/ paint
(on white coating/paint on wood wall siding)
ND N/A
11176-306 Vehicle Bay
Layer 1: Large gage black asphaltic black coating w/ black/brown fibrous wire wrap on black wire insulation on red inner insulation
Layer 2: Metal wire
ND
(All Layers)
N/A
(All Layers)
11176-
307QA
Vehicle Bay
Layer 1: Black asphaltic coating on black/brown/tan fibrous wire wrap on
Layer 2: Black wire insulation on metal wire
ND
(All Layers)
N/A
(All Layers)
11176-308 Vehicle Bay
Layer 1: Old black fibrous electrical tape w/ black asphaltic coating w/ black/ brown fibrous wire wrap
Layer 2: Black/brown fibrous wire wrap
Layer 3: Metal wire
ND
(All Layers)
N/A
(All Layers)
11176-309 Vehicle Bay
Black electrical switch components (loose in 3”x4” junction box)
ND N/A
11176-310 Lunch Room White/gray coating w/ paint
(on concrete wall)
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
FORT VANCOUVER BARRACKS – BUILDING 748
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11176-311 Metal Shop White/gray coating w/ paint
(on concrete wall)
ND N/A
11176-312 Storage
Room
White/gray coating w/ paint
(on concrete wall)
ND N/A
11176-313 Restroom
Layer 1: White/gray coating w/ paint
Layer 2: Black coating/mastic
(on concrete wall)
ND
(All Layers)
N/A
(All Layers)
11176-314 Metal Shop White/gray coating w/ paint
(on concrete wall)
ND N/A
11176-
315QAX1
Parts
Storage
Room 1
Layer 1: Black asphaltic roofing tar debris
Layer 2: Black asphaltic roofing debris
Layer 3: Off-white paint and wood debris (on drop ceilings)
L1: ND
L2: 1.1%
L3: ND
11176-316
Parts
Storage
Room 3
Layer 1: Black asphaltic roofing debris
Layer 2: Wood debris (on drop ceilings)
ND
(All Layers)
N/A
(All Layers)
11176-317
Parts
Storage
Room 3
Black asphaltic tar (dripping through roof decking)
ND N/A
11176-318 Metal Shop
Layer 1: Black asphaltic roofing debris w/ paint
Layer 2: Wood debris (on drop ceilings)
ND
(All Layers)
N/A
(All Layers)
11176-319 Break Room
Layer 1: Black asphaltic roofing debris w/ paint
Layer 2: Wood debris (on drop ceilings)
ND
(All Layers)
N/A
(All Layers)
11176-320 Metal Shop
Black asphaltic tar (dripping through roof deck from newer roofing)
ND N/A
11176-321 Break Room
Layer 1: Black asphaltic insulation w/ red, orange, green, black, and beige wire wraps (on wiring to lights)
Layer 2: Metal wire
ND
(All Layers)
N/A
(All Layers)
11176-322 Basement Plaster ceiling w/ paint ND N/A
11176-
323QA
Basement Plaster ceiling w/ paint ND N/A
11176-324 Basement Plaster ceiling w/ paint ND N/A
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
FORT VANCOUVER BARRACKS – BUILDING 748
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11176-325 Basement Gray flue penetration sealant w/ mastic (into chimney)
ND N/A
11176-326 Basement Plaster debris (in ½ of chimney)
ND N/A
11176-327 Basement Black debris (in ½ of chimney) ND N/A
11176-328 Basement Gray multi-color fibrous fabric wrap (on elbows of water line)
ND N/A
11176-329 Storage
Room
Off-white fire bricks w/ paint
(loose on floor)
ND N/A
11176-330 Break Room
Layer 1: White p-lam countertop
Layer 2: Clear/yellow/brown mastic
ND
(All Layers)
N/A
(All Layers)
11176-331 Break Room
Layer 1: Black rubber sink drain gasket
Layer 2: Brown paper gasket
(on glazed steel sink)
ND
(All Layers)
N/A
(All Layers)
11176-332 Restroom Light gray sink drain plumber’s putty (on glazed steel sink)
ND N/A
11176-333 Restroom
Layer 1: Yellow/white sink drain plumber’s putty
Layer 2: Yellow mastic
ND
(All Layers)
N/A
(All Layers)
11176-334 Roof, N.
Side
Layer 1: Silver coat
Layer 2: Black asphaltic tar
Layer 3: Black asphaltic built-up roofing
Layer 4: Black asphaltic tar
Layer 5: Black asphaltic felt layers
Layer 6: Brown wood fiber insulation
Layer 7: Red paper vapor barrier
Layer 8: Black asphaltic vapor barrier
Layer 9: Black asphaltic tar
Layer 10: Wood decking
ND
(All Layers)
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
FORT VANCOUVER BARRACKS – BUILDING 748
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11176-335 Roof, N.
Side
Layer 1: Silver coat
Layer 2: Black asphaltic tar
Layer 3: Black asphaltic built-up roofing
Layer 4: Black asphaltic tar
Layer 5: Black asphaltic felt layers
Layer 6: Brown wood fiber insulation on red paper vapor barrier
Layer 7: Black asphaltic vapor barrier
Layer 8: Black asphaltic tar
Layer 9: Wood decking
ND
(All Layers)
N/A
(All Layers)
11176-336 Roof, N.
Side
Layer 1: Silver coating
Layer 2: Black asphaltic tar w/ black asphaltic roof patch
ND
(All Layers)
N/A
(All Layers)
11176-337 Roof, N.
Side
Layer 1: Silver coating
Layer 2: Black asphaltic tar (on chimney penetration)
ND
(All Layers)
N/A
(All Layers)
11176-338 Roof, N.
Side
Gray flashing seam sealant
(between flashing and chimney)
ND N/A
11176-339
Roof, Center, N.
Side
Layer 1: Black asphaltic 3-tab roofing w/ granules
Layer 2: Black asphaltic 3-tab roofing w/ granules
Layer 3: Black asphaltic tar
Layer 4: Black asphaltic 3-tab roofing w/ granules
Layer 5: Black asphaltic vapor barrier (on wood)
ND
(All Layers)
N/A
(All Layers)
11176-340
Roof, Center, N.
Side
Layer 1: Black asphaltic 3-tab roofing w/ granules
Layer 2: Black asphaltic 3-tab roofing w/ granules
Layer 3: Black asphaltic tar
Layer 4: Clear plastic
Layer 5: Black asphaltic 3-tab roofing w/ granules
Layer 6: Black asphaltic vapor barrier (on wood)
ND
(All Layers)
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
FORT VANCOUVER BARRACKS – BUILDING 748
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11176-341 Roof, N.
Side
Layer 1: Off-white/gray roof patch sealant w/ trace silver paint
Layer 2: Black asphaltic tar
ND
(All Layers)
N/A
(All Layers)
11176-342 Roof, S.
Side
Layer 1: Silver coat
Layer 2: Black asphaltic tar
Layer 3: Black asphaltic built-up roofing
Layer 4: Black asphaltic tar
Layer 5: Black asphaltic felt layers
Layer 6: Brown wood fiber insulation
Layer 7: Thick black asphaltic tar
Layer 8: Wood decking
ND
(All Layers)
N/A
(All Layers)
11176-343 Roof, S.
Side
Layer 1: Silver coat
Layer 2: Black asphaltic built-up roofing
Layer 3: Black asphaltic felt
Layer 4: Black asphaltic tar
Layer 5: Black asphaltic felt
Layer 6: Brown wood fiber insulation (on black asphaltic tar)
Layer 7: Wood decking
ND
(All Layers)
N/A
(All Layers)
11176-344
Roof, Center, S.
Side
Layer 1: Black asphaltic 3-tab roofing w/ granules
Layer 2: Black asphaltic 3-tab roofing w/ granules
Layer 3: Black asphaltic tar
Layer 4: Black asphaltic 3-tab roofing w/ granules
Layer 5: Black asphaltic tar
Layer 6: Clear plastic
Layer 7: Black asphaltic vapor barrier
Layer 8: Black asphaltic tar (on wood decking)
ND
(All Layers)
N/A
(All Layers)
11176-345
Roof, Center, S.E.
Corner
Layer 1: Gray penetration sealant
Layer 2: Trace black asphaltic sealant (on 1’ OD heat exhaust and 2’ OD roof vents)
ND
(All Layers)
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
FORT VANCOUVER BARRACKS – BUILDING 748
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11176-346 Roof, N.E.
Awning
Layer 1: Black asphaltic 3-tab roofing w/ granules
Layer 2: Black asphaltic tar
Layer 3: Older black asphaltic
3-tab roofing w/ granules
Layer 4: Black asphaltic tar
Layer 5: Clear plastic
Layer 6: Black asphaltic fibrous vapor barrier
Layer 7: Black asphaltic tar (on wood)
ND
(All Layers)
N/A
(All Layers)
11176-347 Roof, N.E.
Awning Beige awning flashing caulking ND N/A
11176-348 Office 1
Layer 1: Black asphaltic 3-tab roofing sheets w/ granules (on floor of room)
Layer 2: Black asphaltic tar
Layer 3: Clear plastic
ND
(All Layers)
N/A
(All Layers)
11176-349 Restroom
Layer 1: Beige paint/coating
Layer 2: Black asphaltic coating w/ brown fibrous wire wrap
Layer 3: Black rubber insulation (on wiring to old lights)
Layer 4: Metal wire
ND
(All Layers)
N/A
(All Layers)
11176-350 Restroom
Layer 1: Black asphaltic coating w/ brown fibrous wire wrap
Layer 2: Black rubber insulation
Layer 3: Metal wire
ND
(All Layers)
N/A
(All Layers)
KEY: GWB = gypsum wall board, JC = joint compound, ND = non-detect, N/A = not applicable, OD = outside diameter, p-lam = plastic laminate, VAT = vinyl composite tile, w/ = with
X When QA lab and primary lab sample results differed, EHSI reported the most restrictive
(e.g., highest % asbestos) in Table 1. Analytical results for all analyses are provided in
Appendix A.
1 Point Counted Results. Preliminary analytical reports indicated that various samples contained approximately 2% chrysotile asbestos (Sample #s 11176-315QA). EHSI re-submitted this sample reported to have greater than 1% asbestos concentration for re-analysis using the more precise EPA “Point Count” method. The “Point Count” analytical method is recommended by the
EPA for samples with less than 10% asbestos. Based on the results of that re-analysis, materials found to contain less than 1% (<1%) asbestos were determined to be a non-ACM (e.g., containing < 1% asbestos fibers) and are therefore not ACM. Materials found to contain greater than 1% asbestos are identified and quantified in Table 2 of this report. Only the “Point Count” re-analysis concentrations are listed in Table 1. Analytical results for all analyses are provided in Appendix A.
Table 2 summarizes materials identified by EHSI as containing greater than 1% asbestos fibers during its survey, and un-sampled materials assumed to be ACM. The Table 2
Summary of Asbestos Containing Materials is for engineering cost estimating purposes and is not intended for bid quantifications.
TABLE 2
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
NATIONAL PARK SERVICE
FORT VANCOUVER BARRACKS – BUILDING 752
ASBESTOS MATERIAL DESCRIPTION LOCATION QUANTITY
Non-ACM orange/red carpet w/ non-ACM beige mastic w/ non-ACM brown burlap backing on
9”x9” maroon/ red VAT w/ ACM black mastic on concrete
[Sample ##s 267 & 268]
Office B1 & B2 300 SF
9”x9” Maroon/red VAT w/ ACM black mastic on concrete
[Sample #s 267 & 268]
Break Room 350 SF
ACM black asphaltic roofing debris w/ non-
ACM black asphaltic roofing tar debris w/ non-
ACM wood and paint debris (on drop ceilings)
[Sample #315QA]
Metal Shop, Break Room, Restroom, Storage 1, Parts
Storage 1, 2, & 3, and
Office 1 & 2
2,225 SF
Small electrical panels and electrical disconnects w/ assumed ACM internal components (<1 SF in size)
Metal Shop, Break Room, Vehicle Bay, and Exterior
19 EA
Electrical panels and electrical disconnects w/ assumed ACM internal components (1 SF to 5
SF in size)
Break Room and Vehicle
Bay
2 EA
4’x1’6” Mirror w/ assumed ACM mastic Restroom 1 EA
2’x2’x3’ Heaters w/ assumed ACM internal components, sealant, and/or insulation Vehicle Bay 2 EA
KEY: ACM = asbestos containing material, EA = each, SF = square feet, VAT = vinyl asbestos tile, w/ = with
ACM identified in this survey should not be disturbed unless handled by personnel who are properly trained and certified in asbestos work. Demolition and/or renovation activities by contractors may expose concealed suspect ACM. Contractors should be aware of the potential for concealed suspect ACM and have pre-planned contingencies for the handling of suspect
ACM discovered during renovation and/or demolition work. Any concealed suspect ACM material that was not sampled or was assumed to be ACM and included in this report, must be treated as ACM until proven otherwise by a Certified AHERA Building Inspector and a certified laboratory. Contingency plans should include stopping work on identification of concealed suspect ACM, evacuation of the area, and sampling by a Certified AHERA Building
Inspector. Concealed suspect material may include, but is not limited to: spray-applied coatings, asphalt or paper vapor barriers and mastics.
2.4.2 Lead-Containing Paint and Building Materials
One hundred thirteen (113) samples were analyzed for lead using the X-Ray fluorescence
(XRF) analyzer. Results marked with “<LOD” contain less lead than the limit of detection. Red bolded results indicate materials containing detectable levels of lead and “lead-based paint” (e.g., >1.0 mg/cm2) as defined by USEPA regulation 40CFR745 and
Washington State Commerce regulation WAC 365-230.
Table 3 summarizes XRF lead samples, including sample number, material description, substrate, color, location and analytical results.
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
NATIONAL PARK SERVICE
FORT VANCOUVER BARRACKS – BUILDING 748
Read
Room Component Substrate Color
Lead Conc.
(mg/cm2)
- SHUTTER CALL N/A N/A N/A 3.85
- CALIBRATION N/A N/A RED 1.0
- CALIBRATION N/A N/A RED 0.9
- CALIBRATION N/A N/A RED 1.0
1 VEHICLE BAY WALL WOOD WHITE 17.0
2 VEHICLE BAY WALL WOOD YELLOW 17.1
3 VEHICLE BAY CONDUIT METAL WHITE 0.08
4 VEHICLE BAY LARGE BAY DOOR FRAME METAL GRAY < LOD
5 VEHICLE BAY LARGE BAY DOOR METAL GRAY < LOD
6 VEHICLE BAY WALL WOOD RED 25.3
7 VEHICLE BAY WALL WOOD LIGHT GRAY 12.3
8 VEHICLE BAY SLIDING DOOR METAL LIGHT BLUE 0.24
9 VEHICLE BAY SLIDING DOOR TRIM WOOD LIGHT GREEN 4.2
10 METAL SHOP SLIDING DOOR FRAME WOOD LIGHT GRAY 4.8
11 METAL SHOP SLIDING DOOR TRIM WOOD LIGHT GRAY 5.0
12 METAL SHOP WALL PLASTER LIGHT GRAY 5.9
13 METAL SHOP WALL PLASTER WHITE 4.2
14 METAL SHOP WALL PLASTER DARK GRAY 5.1
15 METAL SHOP WALL PANEL WOOD DARK GRAY 1.4
16 METAL SHOP WINDOW WOOD GREEN 6.5
17 METAL SHOP WINDOW FRAME/SILL WOOD GREEN 5.9
18 METAL SHOP SOFFIT SYSTEM WOOD WHITE < LOD
19 METAL SHOP ROOF DECKING WOOD OFF-WHITE 14.4
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
NATIONAL PARK SERVICE
FORT VANCOUVER BARRACKS – BUILDING 748
Read
Room Component Substrate Color
Lead Conc.
(mg/cm2)
20 METAL SHOP ROOF JOIST WOOD OFF-WHITE 7.9
21 METAL SHOP COLUMN WOOD WHITE 0.14
22 METAL SHOP COLUMN WOOD LIGHT GRAY 1.3
23 METAL SHOP COLUMN WOOD DARK GRAY 0.07
24 METAL SHOP BEAM WOOD WHITE 7.3
25 VEHICLE BAY DOOR TRIM WOOD LIME GREEN 14.3
26 VEHICLE BAY DOOR FRAME WOOD LIME GREEN 0.11
27 VEHICLE BAY DOOR WOOD LIME GREEN 1.8
28 LUNCH ROOM DOORFRAME WOOD LIGHT GREEN 33.7
29 LUNCH ROOM WALL WOOD OFF-WHITE < LOD
30 LUNCH ROOM WALL PLASTER OFF-WHITE 7.5
31 LUNCH ROOM CABINET WOOD LIGHT GREEN 0.04
32 LUNCH ROOM DOOR WOOD BEIGE 15.3
33 LUNCH ROOM WALL PLASTER OFF-WHITE 7.0
34 LUNCH ROOM ELECTRICAL DISCONNECT METAL BLUE < LOD
35 LUNCH ROOM WALL TRIM WOOD WHITE 20.0
36 VEHICLE BAY ELEC PANEL METAL GRAY 0.06
37 VEHICLE BAY CURB CONCRETE YELLOW 4.3
38 STORAGE 1 WALL PLASTER LIME GREEN 12.6
39 STORAGE 1 WALL PLASTER OFF-WHITE 12.5
40 STORAGE 1 DOOR WOOD OFF-WHITE 16.0
41 STORAGE 1 TRANSOM WINDOW WOOD OFF-WHITE 15.7
42 STORAGE 1 FLOOR CONCRETE GRAY 2.4
43 RESTROOM FLOOR CONCRETE GRAY 1.8
44 RESTROOM CHIMNEY BRICK WHITE 23.2
45 RESTROOM WALL PLASTER WHITE 30.1
46 RESTROOM WALL PLASTER DARK GRAY 25.8
47 RESTROOM SINK CERAMIC WHITE 5.4
48 RESTROOM WINDOW SYSTEM WOOD LIME GREEN 49.1
49 RESTROOM STALL DOOR SYSTEM WOOD WHITE 32.5
50 RESTROOM TOILET & URINAL CERAMIC WHITE 6.8
51 RESTROOM CONDUIT METAL WHITE < LOD
52 RESTROOM DOOR SYSTEM WOOD WHITE 31.9
53 RESTROOM DOOR WOOD CLEAR < LOD
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
NATIONAL PARK SERVICE
FORT VANCOUVER BARRACKS – BUILDING 748
Read
Room Component Substrate Color
Lead Conc.
(mg/cm2)
54 RESTROOM DOORFRAME WOOD LIME GREEN 0.12
55 RESTROOM TRANSOM INFILL WOOD LIME GREEN 0.4
56 VEHICLE BAY WINDOW TRIM WOOD LIGHT GREEN 7.2
57 VEHICLE BAY WINDOW SYSTEM WOOD LIGHT GREEN 12.5
58 VEHICLE BAY WALL WOOD LIGHT GREEN 16.3
59 VEHICLE BAY WALL WOOD WHITE 17.4
60 VEHICLE BAY PIPE METAL WHITE 0.6
61 VEHICLE BAY
LARGE DOUBLE DOOR
TRIM
METAL LIME GREEN 0.8
62 VEHICLE BAY WALL WOOD WHITE 17.1
63 VEHICLE BAY WALL WOOD LIGHT GREEN 14.8
64 VEHICLE BAY CABINET IN WALL WOOD LIGHT GREEN 0.11
65 VEHICLE BAY ELECTRICAL PANEL METAL WHITE 9.6
66 VEHICLE BAY ELECTRICAL PANEL METAL GRAY < LOD
67 VEHICLE BAY FA PANEL METAL RED < LOD
68 VEHICLE BAY CONDUIT METAL WHITE 0.17
69 VEHICLE BAY WOOD RACK WOOD GRAY < LOD
70 VEHICLE BAY DOOR TRIM WOOD AQUA BLUE 14.2
71 VEHICLE BAY DOOR WOOD AQUA BLUE 0.13
72 VEHICLE BAY WINDOW TRIM & SILL WOOD AQUA BLUE 2.3
73 VEHICLE BAY WINDOW WOOD WHITE 4.6
74 VEHICLE BAY COLUMN WOOD WHITE 12.6
75 VEHICLE BAY COLUMN WOOD YELLOW 15.9
76 VEHICLE BAY ROOF JOIST WOOD WHITE 0.07
77 VEHICLE BAY ROOF JOIST WOOD WHITE 0.07
78 VEHICLE BAY ROOF DECKING WOOD WHITE 0.11
79 PARTS STORAGE WALL WOOD WHITE 25.9
80 PARTS STORAGE WALL WOOD GRAY 21.4
81 PARTS STORAGE WINDOW TRIM WOOD GRAY 20.7
82 PARTS STORAGE WINDOW SYSTEM WOOD GRAY 8.0
83 PARTS STORAGE WINDOW SYSTEM WOOD WHITE 14.8
84 PARTS STORAGE COLUMN WOOD WHITE 17.4
85 PARTS STORAGE COLUMN WOOD RED 15.2
86 PARTS STORAGE COLUMN WOOD LIGHT GRAY 9.2
87 PARTS STORAGE WINDOW TRIM WOOD WHITE 18.9
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
NATIONAL PARK SERVICE
FORT VANCOUVER BARRACKS – BUILDING 748
Read
Room Component Substrate Color
Lead Conc.
(mg/cm2)
88 PARTS STORAGE WINDOW SILL WOOD BLACK/BROWN 23.7
89 PARTS STORAGE WALL WOOD WHITE < LOD
90 PARTS STORAGE WALL WOOD DARK GRAY < LOD
91 PARTS STORAGE DOOR/DOOR TRIM WOOD DARK GRAY 25.6
92 PARTS STORAGE 1 WALL WOOD DARK GRAY 4.7
93 PARTS STORAGE 1 WALL WOOD WHITE 5.9
94 PARTS STORAGE 1 WINDOW SYSTEM WOOD GREEN 7.9
95 PARTS STORAGE FIREPLACE CONCRETE GRAY 0.7
96 PARTS STORAGE FLOOR CONCRETE GRAY 0.1
97 PARTS STORAGE CEILING WOOD WHITE < LOD
98 OFFICE 1 WALL WOOD OFF-WHITE 2.2
99 OFFICE 1 WALL TRIM WOOD OFF-WHITE 2.0
100 OFFICE 1 CEILING TRIM WOOD TAN < LOD
101 OFFICE 1 WALL TRIM WOOD AQUA BLUE < LOD
102 OFFICE 1 DOOR TRIM WOOD AQUA BLUE < LOD
103 OFFICE 1 WINDOW TRIM WOOD AQUA BLUE 0.7
104 OFFICE 1 WINDOW SILL WOOD AQUA BLUE 0.5
105 OFFICE 2 DOOR WOOD AQUA BLUE < LOD
106 OFFICE 2 WALL WOOD OFF-WHITE 4.5
107 OFFICE 2 WALL WOOD OFF-WHITE < LOD
108 OFFICE 2 WALL TRIM WOOD TAN < LOD
109 OFFICE 2 WINDOW TRIM/SILL WOOD TAN 0.9
110 OFFICE 2 WINDOW SYSTEM WOOD AQUA BLUE 18.7
111 OFFICE 2 CEILING DRYWALL WHITE < LOD
112 VEHICLE BAY FLOOR STRIPING CONCRETE YELLOW 11.2
113 METAL SHOP FLOOR CONCRETE GRAY 0.18
- CALIBRATION N/A N/A RED 1.0
- CALIBRATION N/A N/A RED 1.0
- CALIBRATION N/A N/A RED 1.0
Key: N/A = not applicable, <LOD = less than limit of detection
All XRF sample shots are representative of that color on that specific substrate and component.
The report user shall deduce from the data in Table 3 and 4, if certain building materials throughout the entire building contain lead and should not assume that what is detected is only in the specific location identified in the Table.
In addition to the XRF samples, EHSI collected three (3) bulk QA samples for laboratory analysis. Building materials and paint containing detectable levels of lead are considered regulated by DOSH.
Table 4 summarizes bulk QA lead samples, including sample number, material description, substrate, color, location, and analytical results. Copies of the analytical laboratory report and field data forms for lead paint are included in Appendix B of this report.
TABLE 4
SUMMARY OF LEAD BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
FORT VANCOUVER BARRACKS – BUILDING 748
SAMPLE
NUMBER
LOCATION COMPONENT/ SUBSTRATE COLOR
RESULTS
% Pb by
WT
11176-Pb11 Vehicle Bay Roof Joist/Wood Beige 0.092
11176-Pb12 Restroom Chimney/Brick & Mortar Beige on Red on Gray 16.0
11176-Pb13 Parts Storage
Room 1 Floor/Concrete Gray 1.7
Key: Pb = lead
DOSH requires employers to conduct a hazard assessment and take appropriate worker protection precautions whenever disturbing materials that have detectable quantities of lead.
Since the type of work planned (e.g., sawing, grinding, demolition) may disturb the lead-containing materials, the contractor will need to conduct lead awareness training and s perform an initial exposure in accordance with WAC 296-155-17609 and hazard communication DOSH regulations.
2.4.3 Toxicity Characteristic Leaching Procedure Sampling
At the request of NPS, EHSI accomplished TCLP sampling and analysis of the assumed waste stream for the project and Table 5 summarizes the analytical results. EHSI collected and composited a representative sample of the assumed waste stream for renovation activities that may impact interior building finishes, that included proportionate quantities of all materials expected to be included in the waste stream. Note: Painted metals were not included in the assumed waste stream sampling, because they are expected to be recycled and because there is no limit on metals containing paint on metals being recycled.
Ecology requires testing using the “toxicity characteristic leaching procedure” (TCLP) and segregation of construction debris if it is potentially contaminated with dangerous waste (e.g., hazardous metals-containing paint/hazardous metals-containing materials). Ecology has set a dangerous waste threshold at 5.0 milligrams per liter (mg/L), for arsenic, chromium, lead, and silver, 1.0 mg/L for cadmium and selenium, 100 mg/L for barium and .2 mg/L for mercury.
The TCLP sample for the Project assumed waste stream was analyzed for the USEPA RCRA 8 metals: Lead (Pb), Cadmium (Cd), Chromium (Cr), Silver (Ag), Arsenic (AS), Barium (Ba), Mercury (hg), Selenium (Se). Copies of the analytical laboratory report and field data forms for the TCLP sample are included in Appendix F of this report.
TABLE 5
SUMMARY OF TCLP SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
FORT VANCOUVER BARRACKS – BUILDING 748
Sample # Elements RL in mg/L Results in mg/L
Results in ppm
11176-
TCLP-
B748-01
Sample Description:
• 34% Painted plywood walls;
• 30% Painted plywood ceilings;
• 10% 9”x9” floor tiles;
• 5% Unpainted plywood walls;
• 4% Unpainted GWB walls;
• 4% Painted spiky texturing on GWB ceilings;
• 4% Carpet;
• 3% Painted wood T-1-11 siding;
• 3% Painted concrete floor;
• 2% Painted wood bathroom stalls; and
• 1% Painted wood baseboards & trim
Silver (Ag) 0.20 <0.20 <0.20
Arsenic (As) 0.20 <0.20 <0.20
Barium (Ba) 0.20 0.23 0.23
Cadmium (Cd) 0.20 <0.20 <0.20
Chromium (Cr) 0.20 <0.20 <0.20
Mercury (Hg) 0.01 <0.011 <0.011
Lead (Pb) 0.20 <0.20 <0.20
Selenium (Se) 0.20 <0.20 <0.20 KEY: Ag = silver, As = Arsenic, Ba = Barium, Cd = Cadmium, Cr = Chromium, Cu = Copper, GWB = gypsum wall board, Hg = Mercury, mg/L = milligram per liter, Ni = Nickel, Pb = Lead, ppm = part per million, RL = Reporting Limit, Se = Selenium, SVF = sheet vinyl flooring, VCT = vinyl composite tile, w/ = with, Zn = Zinc
It should be noted that this TCLP was done on behalf of NPS for disposal cost estimating purposes. It is recommended that the contractor take their own TCLP test of their demolition waste stream including the option to not TCLP specific materials based on the ability to recycle metal and concrete painted building materials.
2.4.4 Polychlorinated Biphenyls
Ballasts
EHSI inspected all fluorescent light fixtures for PCB-containing ballasts. All fixtures were found to contain magnetic ballasts and must be assumed to contain PCB containing dielectric fluid and may be disposed/recycled as Ecology Dangerous Waste. Electronic ballasts, which contain no dielectric fluid, may be disposed as construction debris. A Summary of PCB-containing ballasts and Hg-containing light tubes, CFL bulbs, and HID lamps is provided in Table 6.
2.4.5 Mercury-Containing Fluorescent Light Tubes, CFL Bulbs, and thermostats
All fluorescent light tubes and CFL bulbs quantified in Table 6 contain Hg. Hg wastes are regulated as “universal wastes” under Ecology’s regulation WAC 173-303. Hg-containing building materials must be recycled or disposed of as hazardous waste. One (1) Hg-containing thermostat was identified in the structure.
TABLE 6
SUMMARY OF LIGHT FIXTURE INSPECTION RESULTS
NATIONAL PARK SERVICE
FORT VANCOUVER BARRACKS – BUILDING 748
LIGHT TYPE FIXTURES
TUBES/
BULBS
MAGNETIC
BALLASTS
16”x8’ Mounted light fixture w/ 4 8’ light tubes and 2 large magnetic ballasts 1 4 2
1’x8’ Mounted light fixture w/ 2 8’ light tubes and 1 large magnetic ballast 8 16 8
1’x4’ Mounted light fixture w/ 2 bulbs and 1 magnetic ballast 9 18 9
Light fixture w/ HID lamp 2 2 2
BUILDING 748 TOTAL 40 21
Key: HID = high intensity discharge, w/ = with
2.4.6 Petroleum Hydrocarbon Contaminated Sludge
EHSI assessed for the following constituents/analyses associated with the sludge found in the floor drawings identified by NPS to sample:
• Washington State Department of Ecology (Ecology) Method NWTPH-Dx is the qualitative and quantitative method for semi-volatile petroleum products including jet fuels, kerosene, diesel oils, hydraulic fluids, mineral oils, lubricating oils and fuel oils.
A summary of NWTPH-Dx results is provided in Table 7.
• USEPA 8021B is used to determine volatile organic compounds in a variety of matrices by gas chromatography and photoionization or electrolytic conductivity detectors.
Typical chemicals include benzene, toluene, ethylbenzene, and xylenes (BTEX). A summary of Method 8021B results are provided in Table 8.
• USEPA Test Method 6020B is used to determine concentrations of inorganic analytes
(including arsenic, barium, lead, cadmium, chromium, selenium, silver, and mercury) in a variety of matrices by inductively coupled plasma-mass spectrometry. A summary of Method 6020B results is provided in Table 9.
The samples that exceeded Model Toxics Control Act (MTCA) Method A cleanup levels are listed below:
• 11176-RCRA8-01 for cadmium and lead
• 11176-RCRA8-02 for diesel and oil, and arsenic, cadmium, lead, and mercury
• 11176-RCRA8-03 for diesel and oil, and cadmium and lead
• 11176-RCRA8-04 for cadmium and lead
Copies of the analytical laboratory reports and field data forms for drain sludge sampling are included in Appendix G of this report.
TABLE 7
SUMMARY OF SLUDGE SAMPLES
TOTAL PETROLEUM HYDROCARBONS AS DIESEL AND MOTOR OIL
METHOD NWTPH-DX
NATIONAL PARK SERVICE
FORT VANCOUVER BARRACKS – BUILDING 748
SAMPLE # LOCATION
DIESEL
RANGE
(C10-C25) Results in mg/kg (PPM)
MOTOR OIL
RANGE
(C25-C36) Results in mg/kg (PPM)
SURROGATE
(% RECOVERY)
(Limit 53-144)
Results in mg/kg
(PPM)
11176-RCRA-01 Exterior, E. Drain <100 500 89
11176-RCRA-
02*
Interior, Vehicle
Bay Drain 490 3,200 80
11176-RCRA-
03*
Basement Stair
Drain 250 1,900 83
11176-RCRA-04 Exterior, W. Drain <100 580 88
Method Blank N/A <50 <250 85
KEY: mg/kg = milligram per kilogram, PPM = parts per million
*Bolded Samples 11176-RCRA8-02 and 11176-RCRA8-03 are above MTCA Cleanup levels and should be cleaned up in accordance with applicable regulations.
TABLE 8
BENZENE, TOLUENE, ETHL BENZENE, AND XYLENES
METHOD 8021B
NATIONAL PARK SERVICE
FORT VANCOUVER BARRACKS – BUILDING 748
SAMPLE #
BENZENE
Results in mg/kg
(PPM)
TOLUENE
Results in mg/kg
(PPM)
ETHYL
BENZENE
Results in mg/kg
(PPM)
TOTAL
XYLENES
Results in mg/kg
(PPM)
SURROGATE
(% RECOVERY)
Results in mg/kg (PPM)
11176-TPH-01 <0.02 0.12 <0.04 <0.12 79
11176-TPH-02 <0.02 <0.02 <0.02 <0.06 81
11176-TPH-03 <0.02 0.056 <0.02 0.12 80
11176-TPH-04 <0.02 <0.04 <0.04 <0.12 79
Method Blank <0.02 <0.02 <0.02 <0.06 80
KEY: mg/kg = milligram per kilogram, PPM = parts per million
TABLE 9
RCRA 8 METALS
METHOD 6020B
NATIONAL PARK SERVICE
FORT VANCOUVER BARRACKS – BUILDING 748
SAMPLE # AND
LOCATION
Element
Concentration in mg/kg
(PPM)
11176-RCRA8-01
Exterior East Drain*
Arsenic (As) 2.15
Barium (Ba) 108
Cadmium (Cd) 2.24
KEY: mg/kg = milligram per kilogram, PPM = parts per million, **the chromium is assumed to be trivalent chromium
Chromium (Cr)** 30.4
Lead (Pb) 361
Mercury (Hg) <1
Selenium (Se) <1
Silver (Ag) <1
SAMPLE # AND
LOCATION
Element
Concentration in mg/kg
(PPM)
11176-RCRA8-02
Interior Northeast
Drain*
Arsenic (As) 76.4
Barium (Ba) 454
Cadmium (Cd) 95.2
Chromium (Cr)** 468
Lead (Pb) 13,100
Mercury (Hg) 4.17
Selenium (Se) <1
Silver (Ag) 1.23
SAMPLE # AND
This is the start of the file's text. The full file is on GovTribe.