Exhibit 6 - 12.6 1st Floor Conference Room Split Unit.pdf

PDF 794 KB Posted

Attached to
AOML HVAC and BAS Controls Upgrade Project
Solicitation number
1305M326Q0455
Issued by

About this file

This document is a technical specification and photographic documentation of an HVAC split-unit air conditioning system installed in a 1st Floor Conference Room.

The primary equipment specified is a Coleman split-unit air conditioning system, model GSC130431AR, with a cooling capacity of 3.5 tons (42,000 BTUs). The document explains the manufacturer's naming convention, where the model number digits "042" correspond to 42,000 BTUs of nominal cooling capacity, which converts to exactly 3.5 tons when divided by 12,000 BTUs per ton. A Goodman Manufacturing Company nameplate is also visible in the photographic documentation, indicating the presence of additional HVAC equipment from this manufacturer at the facility. The system includes a condensing unit (outdoor component), indoor evaporative unit, refrigerant lines with service ports, electrical disconnect switch, and a programmable thermostat (Robertshaw brand) for temperature control set to 74 degrees Fahrenheit. The facility floor plan indicates the conference room location with the unit marked in orange overlay. Additional photographs show the outdoor condensing unit placement on a brick pad exterior to the building, the indoor wall-mounted thermostat interface, electrical service components, and the interior conference room with multiple seating arrangements. The system is configured for residential HVAC standards, typical of a 13-SEER efficiency model, and appears to be actively maintained operational equipment.

View the file

Other files

File Type Posted
Attachment 1 - Statement of Work AOML HVAC 1305M326Q0455 Revision 2.pdf PDF
1305M326Q0455 Inquiries and Answers Amend 0003.pdf PDF
RFQ (CSS) 1305M326Q0455 Amend 0003.pdf.pdf PDF
Exhibit 12 - Project Construction Progress Schedule.pdf PDF
Exhibit 1 - 12.1 FCU Chiller RM 406 Magic Aire Model HBB20ABAAAAAB6CB5BAABBM.pdf PDF
REQUIREMENTS-26-4251 HVAC Brand Name Justification BAS System_Redacted.pdf PDF
Exhibit 5 - 12.5 DOAS AOML Hurricane Repairs -100_Drawings July 2019.pdf PDF
1305M326Q0455 Inquiries and Answers_Amend 0002.pdf PDF
Exhibit 13 - Section 019100 Total Building Commissioning.pdf PDF
Exhibit 3 - 12.3 Chiller Room Refrigerant Detector Evacuation Unit Information.pdf PDF
Exhibit 8 - 12.8 FCU Basement Unit.pdf PDF
Exhibit 14 - BUILDER_Inventory_Update_Form_Template.xlsx XLSX spreadsheet
Attachment 2-Davis Bacon Act WDFL20260215 Mod 1_5182026.pdf PDF
Exhibit 4 - 12.4 Drawings 1st Floor VAV 33-35 Mechanical and Electrical Drawings Hallway and Lab.pdf PDF
RFQ (CSS) 1305M326Q0455 Amend 0002.pdf PDF
Exhibit 11 - 12.11 Drawings 1st Floor VAV 18-32 Mechanical and Electrical Drawings PHOD area.pdf PDF
Exhibit 7 - 12.7 Submittals for VAVs 33-67.pdf PDF
Attachment 1 - Statement of Work _AOML HVAC_1305M326Q0455 Revision 1.pdf PDF
Exhibit 2 - 12.2 Sherlock Infrared Refrigerant Gas Sensor and Evacuation System.pdf PDF
Exhibit 10 - 12.10 Drawings 1st Floor VAV 1-17 Mechanical Admin Area.pdf PDF
Exhibit 9 - 12.9 Drawings VAV 36-67 AOML Hurricane Repairs -100_Drawings July 2019.pdf PDF
RFQ (CSS) 1305M326Q0455 Amend 0001.pdf PDF
2. Attachment 1 - Statement of Work, AOML HVAC.pdf PDF
1. RFQ (CSS) 1305M326Q0455.pdf PDF
6. Attachment 2-Davis Bacon Act WD#FL20260215 Mod 1, 5.18.2026.pdf PDF
5. SOW Exhibit 3-BUILDER_Inventory_Update_Form_Template.xlsx XLSX spreadsheet
3. SOW Exhibit 1-Project Construction Progress Schedule.pdf PDF
4. SOW Exhibit 2-Section 019100 Total Building Commissioning.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1st Floor Conference Room Split Unit

Coleman split unit GSC130431AR AC 3.5-ton unit.

The model number GSC130431AR corresponds to a older Coleman split-system air conditioning condensing unit (typically a 13-SEER model)

In residential HVAC naming conventions, manufacturers embed the unit's capacity (measured in

British Thermal Units, or BTUs) directly into the model number. For this Coleman system

(GSC130421AR), the key digits are 042.

• 042 stands for 42,000 BTUs of nominal cooling capacity.

• Since there are 12,000 BTUs in one ton of cooling capacity, you divide the BTUs by 12,000

(\(42,000 \div 12,000\))

This equals exactly 3.5 tons

U ni t

U ni t

U ni t

U ni t

12.9 1st Floor Conference Room Split Unit
Location 1st Floor Conference Room Split Unit

File details come from the government source that posted it. Updated .