Exhibit 3 - 12.3 Chiller Room Refrigerant Detector Evacuation Unit Information.pdf

PDF 2 MB Posted

Attached to
AOML HVAC and BAS Controls Upgrade Project
Solicitation number
1305M326Q0455
Issued by

About this file

This document contains technical specification and equipment information for a chiller room refrigerant detector evacuation unit, specifically detailing the Greenheck Centrifugal Sidewall Exhaust Fan CW-141-A-X model.

The Greenheck CW-141-A-X is a direct-drive centrifugal sidewall exhaust fan designated as EF-1 (Exhaust Fan #1) on standard engineering blueprints. The model designation breaks down as follows: "CW" indicates the centrifugal sidewall exhaust fan line designed to discharge air away from exterior walls; "141" represents the nominal 14-inch backward-inclined aluminum wheel size; and "A/X" denotes specific factory-configured suffix markers for motor tap, voltage configuration, and drive arrangement. The unit features a weather-resistant spun aluminum housing with a round mounting base, engineered specifically for sidewall installation rather than rooftop configurations. Typical applications include clean air ventilation, commercial bathroom exhaust, general building ventilation, and light commercial fume exhaust. The document also includes mechanical equipment schedule drawings, HVAC system schematics with multiple tables covering cooling tower schedules, reciprocating chiller schedules, pump schedules, fan coil unit schedules, heat exchanger schedules, boiler schedules, and facility floor plan layouts showing equipment placement throughout various mechanical and common spaces. Photographs depict the installed evacuation unit mounted on an interior wall and the exhaust fan discharge opening.

View the file

Other files

File Type Posted
Attachment 1 - Statement of Work AOML HVAC 1305M326Q0455 Revision 2.pdf PDF
1305M326Q0455 Inquiries and Answers Amend 0003.pdf PDF
RFQ (CSS) 1305M326Q0455 Amend 0003.pdf.pdf PDF
Exhibit 12 - Project Construction Progress Schedule.pdf PDF
Exhibit 1 - 12.1 FCU Chiller RM 406 Magic Aire Model HBB20ABAAAAAB6CB5BAABBM.pdf PDF
REQUIREMENTS-26-4251 HVAC Brand Name Justification BAS System_Redacted.pdf PDF
Exhibit 5 - 12.5 DOAS AOML Hurricane Repairs -100_Drawings July 2019.pdf PDF
1305M326Q0455 Inquiries and Answers_Amend 0002.pdf PDF
Exhibit 13 - Section 019100 Total Building Commissioning.pdf PDF
Exhibit 8 - 12.8 FCU Basement Unit.pdf PDF
Exhibit 6 - 12.6 1st Floor Conference Room Split Unit.pdf PDF
Exhibit 14 - BUILDER_Inventory_Update_Form_Template.xlsx XLSX spreadsheet
Attachment 2-Davis Bacon Act WDFL20260215 Mod 1_5182026.pdf PDF
Exhibit 4 - 12.4 Drawings 1st Floor VAV 33-35 Mechanical and Electrical Drawings Hallway and Lab.pdf PDF
RFQ (CSS) 1305M326Q0455 Amend 0002.pdf PDF
Exhibit 11 - 12.11 Drawings 1st Floor VAV 18-32 Mechanical and Electrical Drawings PHOD area.pdf PDF
Exhibit 7 - 12.7 Submittals for VAVs 33-67.pdf PDF
Attachment 1 - Statement of Work _AOML HVAC_1305M326Q0455 Revision 1.pdf PDF
Exhibit 2 - 12.2 Sherlock Infrared Refrigerant Gas Sensor and Evacuation System.pdf PDF
Exhibit 10 - 12.10 Drawings 1st Floor VAV 1-17 Mechanical Admin Area.pdf PDF
Exhibit 9 - 12.9 Drawings VAV 36-67 AOML Hurricane Repairs -100_Drawings July 2019.pdf PDF
RFQ (CSS) 1305M326Q0455 Amend 0001.pdf PDF
2. Attachment 1 - Statement of Work, AOML HVAC.pdf PDF
1. RFQ (CSS) 1305M326Q0455.pdf PDF
6. Attachment 2-Davis Bacon Act WD#FL20260215 Mod 1, 5.18.2026.pdf PDF
5. SOW Exhibit 3-BUILDER_Inventory_Update_Form_Template.xlsx XLSX spreadsheet
3. SOW Exhibit 1-Project Construction Progress Schedule.pdf PDF
4. SOW Exhibit 2-Section 019100 Total Building Commissioning.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Chiller Room Refrigerant Detector

Evacuation Unit Information.

Greenheck Centrifugal Sidewall Exhaust Fan CW-141

The Greenheck CW-141-A-X is a direct-drive centrifugal sidewall exhaust fan. The designation

EF-1 stands for Exhaust Fan #1, which is a standard blueprint label used by engineers on mechanical project submittals or building schematics.

CW: Indicates Greenheck's standard Centrifugal Sidewall Exhaust fan line designed to discharge air out and away from exterior walls

141: The nominal wheel size size designation (roughly a 14-inch backward-inclined aluminum wheel).

A / X: Specific suffix markers denoting the motor tap, voltage configuration, or drive arrangement configured by the factory for this layout.

Housing: Features a weather-resistant spun aluminum housing paired with a round mounting base.

Mounting: Specifically engineered for sidewall installation rather than rooftop configurations.

Common Uses: Typically deployed for clean air, commercial bathroom exhaust, general building ventilation, or light commercial fume exhaust applications.

https://www.google.com/search?ibp=oshop&prds=pvt:hg,pvo:29,imageDocid:16958387354046672523,headlineOfferDocid:13448238393397302170,productDocid:13448238393397302170&q=product&sa=X&ved=2ahUKEwj0tbOlrdWWAxUQE1kFHfv2FzcQxa4PegYIAQgJEAE

Poinsettia.Byrd Line

Poinsettia.Byrd Oval

12.11 Chiller Room Refrigerant Detector Evacuation Unit Information
EF 1 AOML 794-816 Mechanical BINDER
Location Chiller Room Ref detector 4th Floor RM 406
EA
EB
EC

File details come from the government source that posted it. Updated .