Attachment 9 - Drawings_Harris Bldg Renovation 100 Percent.pdf
PDF 11 MB Posted
- Attached to
- Petersburg Office Consolidation
- Solicitation number
- 1240BJ24R0018
- Issued by
-
Department of Agriculture Forest Service
About this file
This document appears to be Attachment 9 - Drawings for the Harris Bldg Renovation 100 Percent related to the federal contract opportunity for the Petersburg Office Consolidation project, Solicitation Number 1240BJ24R0018.
The key details are:
- The solicitation is for the PDO Consolidation and Work Center Replacement project in Petersburg, AK on the Tongass National Forest.
- There is a virtual pre-proposal conference scheduled for July 25, 2024 from 1000-1200 Alaska time. Attendees must RSVP by July 24, 2024.
- The deadline for submitting questions/requests for information (RFIs) is close of business on August 9, 2024.
- No substitution requests will be considered prior to award.
- Offerors must respond as described in Sections L and M, and proposals that do not provide a complete response to the Technical Evaluation Factors may be rejected.
- The solicitation is being issued by the Department of Agriculture Forest Service, which is a civilian federal agency.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Petersburg
Juneau
ALASKA
Anchorage
PROJECT LOCATION
M
ITKOF HIGHW
AY
0 - TITLESHEET
G0.00 TITLESHEET
1 - GENERAL
G1.01 GENERAL INFO
G1.02 CODE ANALYSIS
G1.03 CODE PLANS
2 - CIVIL
C.0 GENERAL NOTES, LEGEND, AND ABBREVIATIONS
C.1 EXISTING CONDITIONS AND DEMOLITION
C.2 SITE PLAN
C.3 GRADING PLAN & LAYOUT INFORMATION
C.4 CIVIL TYPICAL SECTIONS
C.5 CIVIL DETAILS (1 OF 2)
C.6 CIVIL DETAILS ( 2 OF 2)
3 - STRUCTURAL
S0.01 STRUCTURAL NOTES & ABBREVIATIONS
S0.02 SPECIAL INSPECTIONS AND TESTING
S1.01 OVERALL FLOOR PLAN
S2.01 FRAMING DETAILS
S3.01 NEW ENTRY PARTIAL PLANS AND DETAILS
4 - ARCHITECTURAL
A0.01 SHEET SPECIFICATIONS
A2.11 DEMO FLOOR PLAN LEVEL 1
A2.12 DEMO FLOOR PLAN LEVEL 2
A2.13 FLOOR PLAN LEVEL 1
A2.14 FLOOR PLAN LEVEL 2
A2.15 ROOF PLAN
A4.01 EXTERIOR ELEVATIONS
A4.02 EXTERIOR ELEVATIONS
A9.03 REFLECTED CEILING PLAN LEVEL 1 & TENT DRYING DIAGRAM
A10.01 EXTERIOR DETAILS
A12.01 SCHEDULES & DOOR TYPES
5 - MECHANICAL
M0.01 MECHANICAL LEGEND
M0.02 MECHANICAL SCHEDULES
M0.03 MECHANICAL SHEET SPECIFICATIONS
M1.01 LEVEL 1 FLOOR PLAN - MECHANICAL - DEMOLITION
M3.01 LEVEL 1 FLOOR PLAN - PLUMBING
M4.01 LEVEL 1 FLOOR PLAN - HVAC
M4.02 LEVEL 2 FLOOR PLAN - HVAC
M5.01 DIAGRAMS AND DETAILS - MECHANICAL
6 - ELECTRICAL
E0.01 LEGEND AND ABBREVIATIONS
E0.02 LIGHTING FIXTURES AND PANEL SCHEDULES
E0.03 ELECTRICAL SPECIFICATIONS
E1.00 SITE PLAN
E1.21 FIRST FLOOR PLAN - LIGHTING - DEMO
E1.31 FIRST FLOOR PLAN - POWER AND SYSS - DEMO
E1.32 SECOND FLOOR PLAN - POWER AND SYSS - DEMO
E2.01 FIRST FLOOR PLAN - LIGHTING
E3.01 FIRST FLOOR PLAN - POWER AND SYSS
E3.02 SECOND FLOOR PLAN - POWER AND SYSS
E6.00 DETAILS & DIAGRAMS
ALASKA
PETERSBURG BOROUGH
R10 ALASKA
TONGASS NATIONAL FOREST
PETERSBURG DISTRICT OFFICE
United States Department of Agriculture
Forest Service
VICINITY MAP
TRAVEL DIRECTIONS:
FOREST LOCATION
FOREST ENGINEER
RECOMMENDED BY:
DISTRICT RANGER
FOREST SUPERVISOR
RO FACILITIES PROGRAM MANAGER
APPROVED:
DIRECTOR OF ENGINEERING DATE
DATE
DATE
DATE
DATE
SHEET 001 OF 046
DIRECTOR OF RECREATION DATE
PETERSBURG OFFICE CONSOLIDATION
& WORK CENTER REPLACEMENT -
HARRIS BUILDING
FROM THE USFS PETERSBURG RANGER DISTRICT OFFICE, TRAVEL SOUTH ON S NORDIC DRIVE WHICH TURNS INTO THE MITKOF HIGHWAY FOR 3 MILES, TURN RIGHT WESTBOUND ON SCOW BAY LOOP ROAD, TURN RIGHT AT 123 SCOW BAY LOOP ROAD, PETERSBURG, ALASKA 99833. 56°46'46.2"N 132°58'02.6"W
SHEET INDEX
BASE BID:
AS DEFINED IN THE SOLICITATION PACKET.
OPTION ITEM 1006 (IN ADDITION TO THOSE PROVIDED IN
SOLICITATION PACKET):
O-1006F - CONTRACTOR INSTALLATION OF METAL
STORAGE SYSTEMS.
ABBREVIATIONS
ABV ABOVE
AFF ABOVE FINISH FLOOR
ALT ALTERNATE
ANO ANODIZED
ARCH ARCHITECTURAL
BD BOARD
BLDG BUILDING
BLK BLOCK
BLW BELOW
BO BOTTOM OF
BOF BOTTOM OF FINISH
BCS BABY CHANGING STATION
CIP CAST IN PLACE
CF CUBIC FOOT
CFOI CONTRACTOR FURNISHED OWNER INSTALLED
CL CENTERLINE
CONC CONCRETE
CONT CONTINUOUS
CTR CENTER
DIA DIAMETER
DIM DIMENSION
DWG DRAWING
EA EACH
EL ELEVATION
ELEC ELECTRICAL
EQ EQUAL
EQUIP EQUIPMENT
EX/(E) EXISTING
FAF FLUID APPLIED FLOORING
FD FRAME DIMENSION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISHED FLOOR
FO FACE OF
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOS FACE OF STUD
FRT FIRE RETARDANT TREATED
FT FOOT, FEET
FURR FURRING
GA GUAGE
GALV GALVANIZED
GB GRAB BAR
IHM INSULATED HOLLOW METAL
INCL INCLUDE, INCLUDED
INSUL INSULATION
INT INTERIOR
LSG LAMINATED SAFETY GLAZING
LH LEFT HAND
MAX MAXIMUM
MFR MANUFACTURER
MKBD MARKERBOARD
MIN MINIMUM
MIRR MIRROR
MTL METAL
NA NOT APPLICABLE
NIC NOT IN CONTRACT
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
OFOI OWNER FURNISHED OWNER INSTALLED
OH OVERHEAD
PAR PARTITION
PERF PERFORATED
PLAM PRESSURE TREATED LAMINATE
PLY/PWD PLYWOOD
PTD PAPER TOWEL DISPENSER
PT PAINT
RCP REFLECTED CEILING PLAN
REBAR/RB REINFORCING BARS
REF REFERENCE
REQD REQUIRED
RO ROUGH OPENING
SD SOAP DISPENSER
SECT SECTION
SCHED SCHEDULE
SIM SIMILAR
SND SANITARY NAPKIN DISPOSAL
SPEC SPECIFICATION
SS STAINLESS STEEL
GWB GYPSUM WALL BOARD
GYP GYPSUM WALL BOARD
HD HAND DRYER
HDWR HARDWARE
HR HOUR
HT HEIGHT
ID INSIDE DIAMETER
STD STANDARD
STL STEEL
STRUCT STRUCTURAL
TBD TO BE DETERMINED
TDWR TOWEL DISPENSER/WASTE RECEPTICAL
THERM THERMOSTAT
TOB TOP OF BEAM
TOC TOP OF CONCRETE
TOS TOP OF STEEL
TTD TOILET TISSUE DISPENSER
TSCD TOILET SEAT COVER DISPENSER
TYP TYPICAL
UL UNDERWRITERS LABORATORY CERTIFIED
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
VIF VERIFY IN FIELD
VR VAPOR RETARDER
WD WOOD
SYMBOLS
GRID LINE INDICATION
ROOM IDENTIFICATION
ROOM NAME
ROOM NUMBER
AREA / OCCUPANCY
A
INTERIOR / EXTERIOR ELEVATION
DASH INDICATES NO ELEVATION
BUILDING SECTION
SECTION NUMBER
SECTION SHEET
DETAIL
DETAIL NUMBER
DETAIL SHEET
DOOR NUMBER
REFER TO DOOR SCHEDULE
JJ
WINDOW TYPE
REFER TO WINDOW SCHEDULE
A1
WALL TYPE INDICATOR
REFER TO WALL LEGEND
WORK POINT
(CONTROL or DATUM POINT)
WALL SECTION
SECTION NUMBER
SECTION SHEET
FLOOR, CEILING, ROOF TYPE INDICATOR
REFER TO FLOOR, CEILING, ROOF LEGEND
F1
KEYNOTE
REFER TO NOTES LISTED ON SHEET1
XXXX -
XX
XX
XX
XX
XX
XX
OFFICE
4 OCC
CEILING TYPE
REFER TO ASSEMBLIES; ELEVATION NOTED ABOVE SLAB
10'-0"
C3
MATERIALS
METAL (SECTION)
WOOD, CONTINUOUS (SECTION)
WOOD, BLOCKING (SECTION)
FILL (SECTION)
PLYWOOD (SECTION)
EARTH (SECTION)
FINISH CARPENTRY (SECTION)
GYPSUM BOARD (SECTION)
INSULATION, BATT (PLAN & SECTION)
INSULATION, RIGID (PLAN & SECTION)
CONCRETE (SECTION)
STONE (PLAN)
MINERAL WOOD INSULATION (PLAN & SECTION)
1. CONSTRUCTION TO BE IN COMPLIANCE WITH ALL FEDERAL,
STATE, AND LOCAL BUILDING CODES AND REGULATIONS.
2. EXISTING CONDITIONS:
A. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS
PRIOR TO COMMENCEMENT OF WORK AND NOTIFY
CONTRACTING OFFICER OF ANY DISCREPANCIES WITH
CONDITIONS AS SHOWN IN DOCUMENTS.
B. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN
ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY
AND MUST BE VERIFIED.
C. THE EXISTING CONDITIONS SHOWN ON THE DRAWINGS
ARE BASED ON EITHER LIMITED AS-BUILTS AND/OR
LIMITED ORIGINAL DRAWINGS. IF THE EXISTING
CONDITIONS DO NOT CLOSELY MATCH THE CONDITIONS
SHOWN ON THE DRAWINGS, OR IF THE EXISTING
MATERIALS ARE OF QUESTIONABLE OR SUBSTANDARD
QUALITY, NOTIFY THE CONTRACTING OFFICER PRIOR TO
COMMENCING WORK.
D. PROTECT ANY EXISTING CONSTRUCTION FROM DAMAGE
AT ALL TIMES DURING WORK.
E. SALVAGE ALL ITEMS THAT ARE TO BE REMOVED BUT
NOT REPURPOSED AND THAT ARE IN GOOD CONDITION.
SUCH ITEMS ARE TO BE PROTECTED AND DONATED.
3. ALL DIMENSIONS ARE TO GRIDLINE OR FACE OF STUD UNLESS
OTHERWISE NOTED. "CLR" REFERS TO FACE OF FINISH EACH
SIDE.
4. WORK AREAS TO BE LEFT CLEAN AND FREE OF ANY DEBRIS AT
THE END OF EACH SHIFT.
5. PROVIDE CONCEALED FRAMING WHERE HEIGHT EXCEEDS
LIMITING HEIGHT OF STUD SIZE.
6. PROVIDE BACKING AS REQUIRED FOR CASEWORK AND OTHER
ITEMS THAT ARE WALL SUPPORTED.
7. SEE MECHANICAL AND PLUMBING DRAWINGS FOR LOCATION
AND TYPE OF PLUMBING FIXTURES.
8. IN CASE OF A CONFLICT IN THE DOCUMENTS, THE
CONTRACTOR SHALL ASSUME THE GREATER VALUE OF SUCH
CIRCUMSTANCES.
9. DOORS ROUGH OPENING SHALL BE LOCATED 6" FROM
ADJACENT WALL FINISH UNLESS NOTED OTHERWISE.
GENERAL NOTES & EXISTING
CONDITIONS
ADA MOUNTING HEIGHTS
THERM
THERM-
OSTAT
LIGHT SWITCH
FEC
ELEC/TEL/DATA
OUTLET @ DOOR
MP
E/DT E/DT
ELEC/TEL/DATA
OUTLET @
WALL
LS
FIRE
EXTINGUISHER
CABINET
T O
F E
M O
U N
T
M A
X T
O H
D W
R
8"
A L
IG
N
W T
.O
D O
O R
T R
IM
U
.O .N
(6
M
IN
/2
" 3
A K
SA
LAFO
ET
A
T S
T C E T I
H
CRA
LANOISSEFO
RP
DE
R
E T S I
G E
R
No. A-140412
JUSTIN M. SCANIO
TH49
07.26.2024
N
S T R
E E T S U
IT
E
A N
C H
O R
A G
E A
L A
S K
A
.5
.5
E
C I/
H y e r, I n c.
C H
E C
K E D
A
U T H
O R
P R
O J E C
T N
O
IS
S U
E D
A T E
R E V
IS
IO
N
FULL SIZE PRINTED ON 22 x 34
O W
N E R
C O
N T R
A C
T
G1.01
G E N
E R
A L I N
F O
-0
.0
C W
R J M
S
.2
.2
P E T E R
S B
U R
G O
F F
IC
E C
O N
S O
L
ID
A T
IO
N
W O
R K
C E N
T E R
R E P
L A
C E M
E N
T
H A
R R
IS
B U
IL
D
IN
G
C O
N S T R
U C
T
IO
N D
O C
U M
E N
T S
1/4" = 1'-0"
ADA MOUNTING HEIGHTS
A K
SA
LAFO
ET
A
T S
T C E T I
H
CRA
LANOISSEFO
RP
DE
R
E T S I
G E
R
No. A-140412
JUSTIN M. SCANIO
TH49
07.26.2024
N
S T R
E E T S U
IT
E
A N
C H
O R
A G
E A
L A
S K
A
.5
.5
E
C I/
H y e r, I n c.
C H
E C
K E D
A
U T H
O R
P R
O J E C
T N
O
IS
S U
E D
A T E
R E V
IS
IO
N
FULL SIZE PRINTED ON 22 x 34
O W
N E R
C O
N T R
A C
T
G1.02
C O
D E A
N A
L Y
S
IS
-0
.0
C W
R J M
S
.2
.2
P E T E R
S B
U R
G O
F F
IC
E C
O N
S O
L
ID
A T
IO
N
W O
R K
C E N
T E R
R E P
L A
C E M
E N
T
H A
R R
IS
B U
IL
D
IN
G
C O
N S T R
U C
T
IO
N D
O C
U M
E N
T S
AUTHORITY HAVING JURISDICTION: US FOREST SERVICE
PROJECT DESCRIPTION: THIS PROJECT IS TO CHANGE THE USE, ALTER,
AND REPAIR AN EXISTING TWO-STORY BUILDING SOUTH OF DOWNTOWN
PETERSBURG. THE BUILDING IS TYPE V-B AND UNSPRINKLERED WITH
NONSEPARATED OCCUPANCIES OF GROUPS B, F-1, AND S-1. LAST
PERMITTED AND CONSTRUCTED UNDER THE 2000 IBC IN 2004.
OWNER: U.S. FOREST SERVICE
PROPERTY LEGAL DESCRIPTION: STEVEN ERICKSON TRACT, LOT FRAG
GOV'T LOTS 1 & 9, SECTIONS 4 & 9, T59S, R79E, CRM
PROPERTY ADDRESS: 123 SCOW BAY LOOP RD, PETERSBURG, AK 99833
APPLICABLE CODES
• PETERSBURG CITY CODE TITLE 19 - ZONING
• 2024 INTERNATIONAL BUILDING CODE
• 2024 INTERNATIONAL FIRE CODE
• 2024 INTERNATIONAL EXISTING BUILDING CODE
• 2024 INTERNATIONAL ENERGY CONSERVATION CODE
• 2024 INTERNATIONAL MECHANICAL CODE
• MORE RESTRICTIVE OF 2024 INTERNATIONAL PLUMBING CODE &
2018 UNIFORM PLUMBING CODE
• 1968 ARCHITECTURAL BARRIERS ACT, 2017 ICC/ANSI A117.1, IBC
CHAPTER 11 FOR ACCESSIBILITY, 2010 ADA STANDARDS FOR
ACCESSIBLE DESIGN
• 2024 NFPA
CODE ANALYSIS
2024 INTERNATIONAL EXISTING BUILDING CODE
202 GENERAL DEFINITIONS:
REPAIR. THE RECONSTRUCTION, REPLACEMENT, OR RENEWAL OF
ANY PART OF AN EXISTING BUILDING FOR THE PURPOSE OF ITS
MAINTENANCE OR TO CORRECT DAMAGE.
THIS PROJECT CONSTITUES REPAIRS TO EXTERIOR ELEMENTS ON
BUILDING. BROKEN OR MISSING ELEMENTS ARE BEING REPLACED
OR RECONSTRUCTED IN KIND AND EXISTING ELEMENTS IN GOOD
CONDITION ARE BEING RENEWED.
ALTERATION. ANY CONSTRUCTION OR RENOVATION TO AN
EXISTING STRUCTURE OTHER THAN A REPAIR OR ADDITION.
PROJECT DOES NOT INCREASE FLOOR AREA, NUMBER OF
STORIES, OR HEIGHT OF BUILDING. PROJECT DOES PROPOSE
WORK WITHIN THE BUILDING THAT CONSTITUTES NEW
CONSTRUCTION.
301.2 REPAIRS:
REPAIRS SHALL COMPLY WITH REQUIREMENTS OF CHAPTER 4.
SEE DISCUSSION BELOW.
301.3 ALTERATION, ADDITION, OR CHANGE OF OCCUPANCY:
PROJECT USES METHOD DESCRIBED IN SECTION 301.3.1. SEE
DISCUSSION BELOW.
301.3.1 PRESCRIPTIVE COMPLIANCE METHOD:
BUILDING COMPLIES WITH IFC. SEE DISCUSSION BELOW.
306.2 DESIGN:
BUILDINGS AND FACILITIES SHALL BE DESIGNED AND
CONSTRUCTED TO BE ACCESSIBLE IN ACCORDANCE WITH THIS
CODE AND THE ALTERATION AND EXISTING BUILDING CONDITIONS
IN ICC A117.1, AS APPLICABLE. SEE DISCUSSION BELOW.
306.3 MAINTENANCE AND REPAIR:
PROJECT WILL MAINTAIN EXISTING ACCESSIBILITY TO BUILDING.
SEE DISCUSSION BELOW.
309.2 [EXTERIOR WALL COVERINGS] ADDITIONS AND REPLACEMENTS:
PROJECT INVOLVES REPAIRS OF EXTERIOR WALL ENVELOPE FOR
LESS THAN 15% OF ANY ONE SIDE OF THE BUILDING.NEW
MATERIALS WILL COMPLY WITH CHAPTERS 14 AND 26 OF THE IBC.
401.2 COMPLIANCE:
REPAIRS MAINTAIN THE EXISTING LEVEL OF SAFETY AND FIRE
PROTECTION.
503.1 [ALTERATIONS] GENERAL:
PROJECT DOES NOT PROPOSE ALTERATIONS THAT MAKE
EXISTING BUILDING LESS COMPLYING.
BUILDING AREA (IBC CODE)
AREA TYPE NAME GROSS AREA
LEVEL 1 INTERIOR FACTORY F-1 1748 SF
LEVEL 1 INTERIOR STORAGE S-1 4118 SF
LEVEL 1 INTERIOR ACCESSORY UTILITY 717 SF
LEVEL 1 INTERIOR BUSINESS 421 SF
LEVEL 1 INTERIOR STORAGE S-1 113 SF
LEVEL 1 INTERIOR STORAGE S-1 127 SF
LEVEL 1 EXTERIOR BUSINESS 54 SF
LEVEL 1 EXTERIOR BUSINESS 151 SF
LEVEL 1 EXTERIOR FACTORY F-1 13 SF
LEVEL 1 EXTERIOR STORAGE S-1 63 SF
100-L1-(39.2')-AFF 7525 SF
LEVEL 2 INTERIOR BUSINESS 3722 SF
LEVEL 2 INTERIOR ACCESSORY S-1 298 SF
LEVEL 2 INTERIOR ACCESSORY S-1 96 SF
LEVEL 2 EXTERIOR BUSINESS 42 SF
ACCESSORY S-1 19 SF
200-L2-AFF 4177 SF
Grand total 11703 SF
TITLE 19
19.44.020 [I-1 DISTRICT, INDUSTRIAL DISTRICT] PRINCIPAL USES
PERMITTED:
BUILDING CONTAINS OFFICES AND STORAGE FACILITIES, AS WELL
AS MANUFACTURING.
19.44.050 SCREENING OF STORAGE REQUIRED:
SEE SITE PLAN. STORAGE SCREENED FROM VIEW WITH HEDGE.
19.32.080 LOT, YARD, AND HEIGHT:
SEE BUILDING ELEVATIONS. BUILDING IS BELOW MAXIMUM HEIGHT.
19.64.010 PARKING AREAS - REQUIREMENTS ACCORDING TO USE:
BUILDING HAS APPRAISED VALUE OF $12,600. PROJECT COST
EXCEEDS 50% OF VALUE. BUILDING IS 11,650 SF AND REQUIRES 10
OFF-STREET PARKING SPACES. SITE PROVIDES 25 PARKING
SPACES.
19.64.040 DESIGN STANDARDS:
A. EACH PARKING SPACE SHALL CONTAIN NOT LESS THAN 8 FT
WIDE BY 20 FT LONG IN AREA EXCLUSIVE OF ACCESS AND
CIRCULATION AISLES. […] C. ANY LIGHTING OF PARKING LOTS
SHALL BE ARRANGED TO REFLECT AWAY FROM PUBLIC RIGHTS-
OF-WAY AND FROM ANY ADJOINING RESIDENTIAL AREA. SEE SITE
PLAN.
19.64.070 PARKING AREAS - ACCESS:
[…] NO DRIVEWAY, PARKING LOT OR CURB CUTS IN ANY DISTRICT
SHALL EXCEED […] FOURTY FEET IN WIDTH FOR COMMERCIAL […]
STRUCTURES, AND DETAILED PLANS FOR ALL CURB CUTS SHALL
BE SUBMITTED TO THE CITY ENGINEERING DEPARTMENT OR
DESIGNATED REPRESENTATIVE FOR APPROVAL BEFORE A PERMIT
SHALL BE ISSUED THEREFORE. SEE SITE PLAN.
19.64.080 LOADING AREAS - WHERE REQUIRED:
LOADING AREAS PROVIDED.
19.64.100 LOADING AREAS - ACCESS:
LOADING AREAS ACCESS STREET.
506.1 [CHANGE OF OCCUPANCY] COMPLIANCE:
PROJECT CHANGES OCCUPANCY OF BUILDING FROM B TO
NONSEPARATED B, F-1, S-1 CONSTITUTING A GREATER FIRE RISK
BUT NOT LIFE RISK. HOWEVER, THE BUILDING IS MADE TO COMPLY
WITH THE REQUIREMENTS OF THE IBC FOR THOSE OCCUPANCIES.
506.3 STAIRWAYS:
EXISTING STAIRS COMPLY WITH IBC REQUIREMENTS IN SECTION
1011.
2024 INTERNATIONAL BUILDING CODE
202 DEFINITIONS:
AREA, BUILDING. THE AREA INCLUDED WITHIN SURROUNDING
EXTERIOR WALLS EXCLUSIVE OF VENT SHAFTS AND COURTS.
AREAS OF THE BUILDING NOT PROVIDED WITH SURROUNDING
WALLS SHALL BE INCLUDED IN THE BUILDING AREA IF SUCH AREAS
ARE INCLUDED WITHIN THE HORIZONTAL PROJECTION OF THE
ROOF OR FLOOR ABOVE.
FIRE AREA. THE AGGREGATE FLOOR AREA ENCLOSED AND
BOUNDED BY FIRE WALLS, FIRE BARRIERS, EXTERIOR WALLS, OR
HORIZONTAL ASSEMBLIES OF A BUILDING. AREAS OF THE
BUILDING NOT PROVIDED WITH SURROUNDING WALLS SHALL BE
INCLUDED IN THE FIRE AREA IF SUCH AREAS ARE INCLUDED
WITHIN THE HORIZONTAL PROJECTION OF THE ROOF OR FLOOR
NEXT ABOVE.
SEE DISCUSSION BELOW. FIRE AREA IS UNDER 12,000 SF AND
EXTERIOR AREAS NOT PROVIDED WITH SURROUNDING WALLS BUT
INCLUDED WITHIN HORIZONTAL PROJECTION OF ROOF ABOVE.
PRIVATE GARAGE. A BUILDING OR PORTION OF A BUILDING IN
WHICH MOTOR VEHICLES USED BY THE OWNER OR TENANTS OF
THE BUILDING […] ON THE PREMISES ARE STORED OR KEPT,
WITHOUT PROVISIONS FOR REPAIRING OR SERVICING SUCH
VEHICLES FOR PROFIT.
BUILDING INCLUDES PRIVATE GARAGE AREA FOR THE STORAGE
OF VEHICLES OWNED BY BUILDING OWNER AND REPAIRS OR
SERVICES ARE NOT CONDUCTED FOR PROFIT.
302.1 [OCCUPANCY CLASSIFICATION AND USE] GENERAL:
BUILDING CONTAINS GROUPS B, F-1, AND S-1 NONSEPARATED
OCCUPANCIES. SEE BUILDING AREA TABLE FOR OCCUPANCY
CLASSIFICATIONS.
304.1 BUSINESS GROUP B:
PORTION OF BUILDING USED FOR OFFICE PURPOSES.
311.2 MODERATE-HAZARD FACTORY INDUSTRIAL, GROUP F-1:
SHOP AREAS CONTAIN ACTIVITIES INCLUDING MINOR SERVICE OF
BOAT ENGINES, SMALL ENGINE REPAIR, WOOD CONSTRUCTION.
312.1 [UTILITY AND MISCELLANEOUS GROUP U] GENERAL:
BUILDING CONTAINS A PRIVATE GARAGE. THIS IS AN ACCESSORY
USE.
312.2 PRIVAGE GARAGES AND CARPORTS:
PRIVATE GARAGES […] SHALL COMPLY WITH SECTION 406.3. SEE
DISCUSSION BELOW.
406.2.2 [MOTOR-VEHICLE-RELATED OCCUPANCIES] CLEAR HEIGHT:
CEILING HEIGHT EXCEEDS 7 FT IN VEHICLE AREA.
406.2.4 FLOOR SURFACES:
FLOOR SURFACE IS CONCRETE AND IS EXISITING. NO SLOPING
COMPONENT OR FLOOR DRAIN IS PROPOSED. NO FLUIDS WORK
WILL OCCUR IN PRIVATE GARAGE.
406.3.1 CLASSIFICATION:
GARAGE HAS AN AREA OF 717 SF.
406.3.2 SEPARATION:
BUILDING DOES NOT CONTAIN DWELLING UNITS. SEE DISCUSSION
BELOW. BUILDING HAS NONSEPARATED OCCUPANCIES.
504.3 HEIGHT IN FEET:
SEE TABLE 504.3. BUILDING COMPLIES WITH TABLE ALLOWANCES.
SEE ELEVATIONS FOR BUILDING HEIGHT.
504.4 NUMBER OF STORIES:
SEE TABLE 504.4. BUILDING COMPLIES WITH TABLE ALLOWANCES.
506.2 ALLOWABLE AREA DETERMINATION:
SEE TABLE 506.2. BUILDING COMPLIES WITH TABLE ALLOWANCES.
SEE BUILDING AREA SUMMARY AND CODE PLANS FOR LEVEL
AREAS.
506.2.2 MIXED-OCCUPANCY BUILDINGS:
SEE TABULATION INCLUDED WITH TABLE 506.2. SEE DISCUSSION
BELOW.
TABLE 504.3: ALLOWABLE BLDG HEIGHT IN FT ABOVE GRADE PLANE
OCC CLASS SPRINKLER TYPE VALUE
B/S/F NS V-B 40
TABLE 504.4: ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE
OCC CLASS SPRINKLER TYPE VALUE
B NS V-B 2
S-1/F-1 NS V-B 1
TABLE 506.2: ALLOWABLE AREA FACTOR (At) IN SQUARE FEET
OCC CLASS SPRINKLER TYPE VALUE
B/S/F NS V-B 8,500
506.2.1: MAXIMUM ALLOWABLE AREA AA IN SQUARE FEET
AA = 15,750 SF PER STORY
At = 8,500
NS = 8,500
If = 0.75
506.3.1 [FRONTAGE INCREASE] MINIMUM PERCENTAGE OF PERIMETER:
BUILDING IS 75% SURROUNDED BY OPEN SPACE OR PUBLIC WAY
506.3.2 MINIMUM FRONTAGE DISTANCE:
BUILDING HAS THREE SIDES FACING AN OPEN SPACE AND PUBLIC
WAY THAT EXCEEDS THE MINIMUM DISTANCES FOR (W).
506.3.3 AMOUNT OF INCREASE:
PER TABLE 506.3.3, IF EQUALS 0.75.
508.2.1 [ACCESSORY] OCCUPANCY CLASSIFICATION:
BUILDING HAS A PRIVATE GARAGE WITH U OCCUPANCY ON LEVEL
1 AND STORAGE AREAS ON LEVEL 2 WITH S-1 OCCUPANCY.
508.2.2 ALLOWABLE BUILDING HEIGHT:
ALLOWABLE HEIGHT AND NUMBER OF STORIES FOR GROUPS S-1
AND B USED PER SECTION 504. MAIN OCCUPACY OF LEVEL 1 IS
GROUP S-1, LIMITED TO 1 STORY. MAIN OCCUPANCY OF LEVEL 2 IS
GROUP B, LIMITED TO 2 STORIES.
508.2.3 ALLOWABLE BUILDING AREA:
ALLOWABLE AREA FOR GROUP S-1 FOR LEVEL 1 AND B FOR LEVEL
2 USED PER SECTION 506. ACCESSORY OCCUPANCIES DO NOT
CONSTITUTE GREATER THAN 10% OF THE FLOOR AREA OF EACH
STORY AND DO NOT EXCEED VALUES IN TABLE 506.2 FOR
NONSPRINKLERED U OR S-1. LEVEL 1 HAS NONSEPARATED
OCCUPANCIES AND PRIVATE GARAGE IS CLASSIFIED AS S-1.
STORAGE ROOMS WITH S-1 OCCUPANCIES ON LEVEL 2 DO NOT
EXCEED 10% OF THE FLOOR AREA OF THAT FLOOR. PRIMARY
OCCUPANCY CLASSIFICATION OF STORY IS GROUP B.
508.2.4 SEPARATION OF OCCUPANCIES:
NO SEPARATION PROVIDED.
508.3.1 [NONSEPARATED OCCUPANCIES] OCCUPANCY CLASSIFICATION:
NO SEPARATE PROVIDED BETWEEN OCCUPANCIES. CODE
APPLIED TO EACH PORTION OF THE BUILDING EXCEPT THAT THE
MOST RESTRICTIVE PROVISIONS OF CHAPTER 9 APPLY TO THE
THE TOTAL AREA.
508.3.2 ALLOWABLE BUILDING AREA, HEIGHT, AND NUMBER OF STORIES:
SEE TABLES 504.3, 504.4, 506.2. AREA OF EACH STORY IS BELOW
THE MINIMUM AREA, HEIGHT, AND STORY NUMBER FOR THE MOST
RESTRICTIVE GROUP UNDER CONSIDERATION FOR THAT STORY.
TABLE 705.5: FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR
WALLS BASED ON FIRE SEPARATION DISTANCE
FSD TYPE OF GROUP B/F-1/S-1
(FT) CONSTRUCTION
10≤X<30 V-B 0 HRS
X≥30 ALL 0 HRS
TABLE 601: FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING
ELEMENTS (HOURS)
TYPE V-B:
PRIMARY STRUCTURAL FRAME: 0 HRS
BEARING WALLS:
EXTERIOR: 0 HRS
INTERIOR: 0 HRS
NONBEARING WALLS & PARTITIONS:
EXTERIOR: SEE TBL 705.5
INTERIOR: 0 HRS
FLOOR CONSTRUCTION, ETC: 0 HRS
ROOF CONSTRUCTION, ETC: 0 HRS
601 [TYPES OF CONSTRUCTION] GENERAL:
SEE TABLE 601. BUILDING IS TYPE V-B CONSTRUCTION. SEE
DISCUSSION BELOW.
602.5 TYPE V:
BUILDING IS CONSIDERED TYPE V-B CONSTRUCTION.
705.2 PROJECTIONS:
PROJECTIONS DO NOT EXTEND TO WITHIN 40 INCHES OF LINE
USED TO DETERMINE FSD.
705.2.2 TYPE III, IV, OR V CONSTRUCTION:
PROJECTIONS CONSTRUCTED FROM APPROVED MATERIALS.
705.8.1 ALLOWABLE AREA OF OPENINGS:
EXTERIOR WALLS WITH FSD BETWEEN 15 AND 20 FEET HAVE
UNPROTECTED OPENINGS THAT DO NOT MAKE UP GREATER THAN
25% OF THE WALL AREA. THOSE WALLS WITH GREATER THAN 30
FEET FSD HAVE UNLIMITED UNPROTECTED OPENING AREAS.
705.11 PARAPETS:
TABLE 705.5 ALLOWS ALL WALLS TO HAVE NO FIRE-RESISTANCE
RATING. NO PARAPET PROVIDED AT EXTERIOR WALLS.
708.5 EXTERIOR WALLS:
SEE TABLE 705.5. EXTERIOR WALLS OF BOILER ROOM HAVE
GREATER THAN 10 FT FSD SO REQUIRE 0 HR FIRE-RESISTANCE
RATING. EXTERIOR WALLS OF BOILER ROOM NOT RATED.
712.1.9 TWO-STORY OPENINGS:
VERTICAL OPENING IN SECOND STORY CONNECTS ONLY TWO
STORIES, THERE IS NO HORIZONTAL ASSEMBLY BETWEEN THE
STORIES, THE SPACE IS OPEN AND OCCUPIED AND SURROUNDED
BY COMPLETE WALL ASSEMBLIES, THE BUILDING DOES NOT
CONTAIN I OR R OCCUPANCIES, THE OPENING DOES NOT OPEN TO
A CORRIDOR, AND THE OPENING HAS SEPARATIONS TO SHAFT
ENCLOSURES.
803.13 INTERIOR FINISH REQUIREMENTS BASED ON OCCUPANCY:
SEE TABLE 803.13. ALL NEW FINISHES MEET FLAME SPREAD INDEX
REQUIREMENTS.
TABLE 803.13: INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY
OCCUPANCY (NONSPRINKLERED)
GROUP: INT EXIT EXIT ACCESS ROOMS
STAIRS EXIT STAIRS/RAMPS
B & S B B C F B C C
U NR NR NR
804.4.2 [INTERIOR FLOOR FINISH] MINIMUM CRITICAL RADIANT FLUX:
ALL NEW INTERIOR FLOORS HAVE MINIMUM CRITICAL RADIANT
FLUX OF NOT LESS THAN CLASS II.
806.7 INTERIOR TRIM:
EXISTING INTERIOR TRIM THAT IS COMBUSTIBLE DOES NOT
EXCEED 10% OF WALL OR CEILING AREA. ALL NEW TRIM HAS
MINIMUM CLASS C FLAME SPREAD OR IS COMBUSTIBLE AND DOES
NOT EXCEED THE AREA LIMIT.
806.8 INTERIOR FLOOR-WALL BASE:
FLOORS REQUIRED TO BE CLASS II; FLOOR BASE IS LESS THAN 6"
IN HEIGHT AND IS CLASS II.
903.2.4 GROUP F-1:
NO AUTOMATIC SPRINKLER SYSTEM PROVIDED. BUILDING
CONTAINS F-1 OCCUPANCY BUT FIRE AREA OF BUILDING IS NOT
GREATER THAN 12,000 SF.
903.2.4.1 WOODWORKING OPERATIONS:
NO AUTOMATIC SPRINKLER SYSTEM PROVIDED. SHOP AREAS
INCLUDE WOODWORKING OPERATIONS BUT AREA DOES NOT
EXCEED 2,500 SF. MECHANICAL WOODWORKING EQUIPMENT
PROVIDED WITH CLOSED DUST COLLECTION SYSTEM.
903.2.9 GROUP S-1:
NO AUTOMATIC SPRINKLER SYSTEM PROVIDED. BUILDING
CONTAINS S-1 OCCUPANCY BUT FIRE AREA OF BUILDING IS NOT
GREATER THAN 12,000 SF.
906.1 [PORTABLE FIRE EXTINGUISHERS] WHERE REQUIRED:
PORTABLE FIRE EXTINGUISHERS SHALL BE INSTALLED IN THE
FOLLOWING LOCATIONS. 1. IN [GROUP B, F, AND S] OCCUPANCIES;
[…] 3. IN AREAS WHERE FLAMMABLE OR COMBUSTIBLE LIQUIDS
ARE STORED, USED OR DISPENSED; 4. ON EACH FLOOR OF
STRUCTURES UNDER CONSTRUCTION [...]; 6. SPECIAL-HAZARD
AREAS, INCLUDING BUT NOT LIMITED TO [...] WHERE REQUIRED BY
THE FIRE CODE OFFICIAL. SEE CODE PLANS.
[F] TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS:
LIGHT HAZARD (B) OCCUPANCY: 2-A PER 3,000 SF PER UNIT OF A,
11,250 SF PER EXTINGUISHER, 75 FT TRAVEL DISTANCE. ORDINARY
HAZARD (S-1, F-1) OCCUPANCY: 2-A PER 1,500 SF PER UNIT OF A,
11,250 SF PER EXTINGUISHER, 75 FT TRAVEL DISTANCE. SEE CODE
PLANS. BUILDING HAS EXTINGUISHERS PROVIDED THROUGHOUT.
1003.2 [GENERAL MEANS OF EGRESS] CEILING HEIGHT:
CEILING HAS PROTRUDING ELEMENTS THAT REDUCE HEADROOM.
SEE DISCUSSION BELOW.
1003.3.2 [PROTRUDING OBJECTS] HEADROOM:
SOME PROTRUDING OBJECTS EXTEND BELOW MINIMUM CEILING
HEIGHT. THESE DO NOT COMPRISE MORE THAN 50% OF CEILING
AREA AND PROVIDE A HEADROOM OF GREATER THAN 80".
BARRIER PROVIDED AT AREAS WHERE CIRCULATION PATH HAS A
CLEARANCE LESS THAN 80".
1003.3.3 HORIZONTAL PROJECTIONS:
OBJECTS BETWEEN 27" AND 80" ABOVE FINISHED FLOOR DO NOT
PROJECT GREATER THAN 4" INTO THE CIRCULATION PATH.
1003.3.4 CLEAR WIDTH:
PROTRUDING OBJECTS DO NOT REDUCE THE MINIMUM CLEAR
WIDTH OF ACCESSIBLE ROUTES.
1003.4 SLIP-RESISTANT SURFACE:
FLOORS IN CIRCULATION PATHS ARE NON-SLIP AND SECURELY
ATTACHED.
1004.2.1 [CUMULATIVE OCCUPANT LOADS] INTERVENING SPACES OR
ACCESSORY AREAS:
WHERE OCCUPANTS EGRESS FROM ONE OR MORE ROOMS,
AREAS, OR SPACES THROUGH OTHERS, THE DESIGN OCCUPANT
LOAD SHALL BE THE COMBINED OCCUPANT LOAD OF
INTERCONNECTED ACCESSORY OR INTERVENING SPACES.
DESIGN OF EGRESS PATH CAPACITY SHALL BE BASED ON THE
CUMULATIVE PORTION OF OCCUPANT LOADS OF ALL ROOMS,
AREAS, OR SPACES TO THAT POINT ALONG THE PATH OF EGRESS
TRAVEL. SEE CODE PLANS.
1004.5 AREAS WITHOUT FIXED SEATING:
SEE ROOM OCCUPANT LOAD TABLE.
OCCUPANT LOAD CALCULATION SUMMARY:
RM OCC AREA OCC AREA OCC
CLASSIFICATION (SF) LOAD FACTOR TYPE LOAD
BUSINESS: 421 150 GROSS 2.8
FACTORY (INDUSTRIAL): 1681 100 GROSS 16.8
WAREHOUSE STORAGE: 4358 500 GROSS 8.7
ACCESSORY GARAGE: 717 200 GROSS 3.6
MECH: 67 300 GROSS 0.2
EXTERIOR AREAS: 229 300 GROSS 0.8
LEVEL 1 TOTAL: 7473 32.9
BUSINESS: 3678 150 GROSS 24.5
MECH/STORAGE: 456 300 GROSS 1.5
EXTERIOR AREAS: 42 300 GROSS 0.1
LEVEL 2 TOTAL: 4176 26.1
BUILDING TOTAL: 59
1004.7 OUTDOOR AREAS:
BUILDINGS HAVE COVERED EXTERIOR AREAS ASSOCIATED WITH
THE BUILDING USE. THESE ARE FREE AND OPEN TO A PUBLIC
WAY.
1005.1 [MEANS OF EGRESS SIZING] GENERAL:
BUILDINGS ARE EXISTING AND EXISTING MEANS OF EGRESS WILL
BE MAINTAINED. EXISTING MEANS OF EGRESS COMPLY WITH
STANDARDS OF IBC.
1005.3.1 STAIRWAYS:
SEE CODE PLANS. EXISTING EXIT STAIRWAYS COMPLY WITH
STANDARD BUT ARE NOT MODIFIED WITH PROJECT.
1005.3.2 OTHER EGRESS COMPONENTS:
SEE CODE PLANS. EXISTING COMPONENTS OF EGRESS COMPLY
WITH STANDARD AND WILL NOT BE MODIFIED WITH PROJECT.
NEW COMPONENTS OF EGRESS WILL COMPLY WITH STANDARD.
1005.4 CONTINUITY:
EXISTING COMPONENTS OF EGRESS MEET STANDARDS FOR
CAPACITY. LEVEL OF PROTECTION IS NOT REDUCED BY WORK.
1005.5 DISTRIBUTION OF MINIMUM WIDTH AND REQUIRED CAPACITY:
STORIES OF BUILDING AND SPACES REQUIRE MORE THAN ONE
EXIT. LOSS OF ONE EXIT DOES NOT REDUCE THE AVAILABLE
CAPACITY TO LESS THAN 50% OF THE REQUIRED CAPACITY.
1005.7.1 [ENCROACHMENT] DOORS:
SEE CODE PLANS. DOORS WHEN FULLY OPENED DO NOT REDUCE
REQUIRED WIDTH BY MORE THAN 7".
1005.7.2 OTHER PROJECTIONS:
HANDRAILS PROJECT INTO REQUIRED WIDTH PER SECTION 1014.8.
1006 NUMBER OF EXITS AND EXIT ACCESS DOORWAYS:
BUILDING IS EXISTING. WORK DOES NOT REDUCE NUMBER OR
CAPACITY OF EXITS.
TABLE 1020.3: MINIMUM CORRIDOR WIDTH (IN)
ANY FACILITY NOT LISTED 44
MECH ACCESS 24
<50 OCC 36
1020.5 DEAD ENDS:
SEE ARCHITECTURAL DRAWINGS. CORRIDORS DO NOT HAVE
GREATER THAN 20 FT DEAD-ENDS.
1023.1 [INTERIOR EXIT STAIRWAYS AND RAMPS] GENERAL:
INTERIOR EXIT STAIR IS EXISTING AND NOT MODIFIED. STAIR MAY
MAINTAIN THE EXISTING LEVEL OF PROTECTION PER THE IEBC.
1027.3 [EXTERIOR EXIT STAIRWAYS AND RAMPS] OPEN SIDE:
BUILDING HAS EXISTING EXTERIOR EXIT STAIRWAY NOT ALTERED
WITH PROJECT. ALL WORK CONDUCTED TO THESE ELEMENTS
CONSTITUTES REPAIRS. ELEMENTS CONSIDERED CONFORMING
WITH 2000 IBC. EXISTING WIDTHS ACCOMMODATE REQUIRED
CAPACITIES.
1028.5 ACCESS TO A PUBLIC WAY:
SEE SITE PLAN. ALL EXITS DISCHARGE TO PUBLIC WAY.
1104.1 SITE ARRIVAL POINTS:
SEE SITE PLAN. ACCESSIBLE ROUTE PROVIDED FROM ACCESSIBLE
PARKING TO ACCESSIBLE BUILDING ENTRANCES. BUILDING IS
EXISTING AND HAS ACCESSIBLE ENTRANCE NOT BEING MODIFIED
IN PROJECT. MODIFIED ENTRANCES NOT REQUIRED TO BE
ACCESSIBLE. NEW ENTRANCE WILL BE ON ACCESSIBLE ROUTE.
1104.2 WITHIN A SITE:
SEE SITE PLAN. ACCESSIBLE ROUTE PROVIDED ON-SITE TO ALL
ACCESSIBLE FACILITIES, ELEMENTS, AND SPACES.
1104.3 CONNECTED SPACES:
SEE ARCHITECTURAL DRAWINGS. BUILDING HAS AN ACCESSIBLE
ROUTE TO ALL ACCESSIBLE SPACES. SEE DISCUSSION BELOW.
1104.4 MULTISTORY BUILDINGS AND FACILITIES:
EACH STORY HAS ACCESSIBLE SPACES AND AN ACCESSIBLE
ROUTE IS PROVIDED TO EACH STORY.
1104.5 LOCATION:
ACCESSIBLE ROUTE PROVIDED WITHIN BUILDING WITH EXISTING
ELEVATOR.
1105.1 [ACCESSIBLE ENTRANCES] PUBLIC ENTRANCES:
BUILDING IS NOT OPEN TO THE PUBLIC. MAIN ENTRANCE
COMPLIES WITH STANDARDS FOR ACCESSIBLE ENTRANCES.
1105.1.1 AUTOMATIC DOORS:
BUILDING OCCUPANT LOAD IS LESS THAN 500, THE NUMBER
REQUIRING AUTOMATIC DOOR OPERATION.
1105.1.4 RESTRICTED ENTRANCES:
ONE RESTRICTED ENTRANCE IS ACCESSIBLE.
1106.2 [PARKING AND PASSENGER LOADING FACILITIES] REQUIRED:
SEE SITE PLAN. PARKING AREA PROVIDES TWO ACCESSIBLE
PARKING SPACES.
1106.6 VAN SPACES:
SEE SITE PLAN. AT LEAST ONE VAN-ACCESSIBLE PARKING SPACE
PROVIDED.
1110.2 TOILET AND BATHING FACILITIES:
EACH FLOOR PROVIDED WITH ONE EXISTING ACCESSIBLE SINGLE-
USER TOILET ROOM PER GENDER. NO WORK PROPOSED IN TOILET
ROOMS.
2024 INTERNATIONAL PLUMBING CODE
TABLE 403.1 MINIMUM NUMBER OF REQUIRED FIXTURES:
EXISTING FACILITIES MEET REQUIREMENTS FOR 2024 IPC. NO
CHANGES REQUIRED. SEE TABLE 403.1.
1009.1 ACCESSIBLE MEANS OF EGRESS REQUIRED:
BUILDINGS HAVE ACCESSIBLE MEANS OF EGRESS PER THE 2000
IBC. NEW WORK DOES NOT REDUCE ACCESSIBLE MEANS OF
EGRESS.
1010.1.1 SIZE OF DOORS:
PROJECT PROPOSES REPAIRING AND REPLACING EGRESS
DOORS. ALL EGRESS DOORS ARE REPLACED IN-KIND WITH THE
SAME DIMENSIONS PER IEBC. PROJECT DOES NOT REDUCE THE
EXISTING LEVEL OF PROTECTION.
1010.2.2 HARDWARE:
SEE HARDWARE SCHEDULE. NEW DOORS OR EXISTING DOORS
MODIFIED AND REQUIRED TO BE ACCESSIBLE WILL HAVE
HARDWARE COMPLYING WITH THIS PROVISION.
1010.2.3 HARDWARE HEIGHT:
SEE DOOR SCHEDULE. BUILDING IS EXISTING AND AND EXISTING
HARDWARE WILL BE RETAINED WHERE NOT ALTERED. NEW
HARDWARE WILL COMPLY WITH THIS PROVISION.
1011 STAIRWAYS:
STAIRWAYS MAINTAIN EXISTING LEVELS OF PROTECTION PER
IEBC AND MEET CAPACITY REQUIREMENTS OF NEW USE.
1012 RAMPS:
NEW RAMPS COMPLY WITH SECTION 1012.
1014.2 [HANDRAILS] HEIGHT:
EXISTING HANDRAILS NOT MODIFIED BY WORK AND ALLOWED TO
REMAIN PER IEBC. NEW HANDRAILS COMPLY WITH THE
STANDARD.
1014.3 HANDRAIL GRASPABILITY:
EXISTING HANDRAILS NOT MODIFIED BY WORK AND ALLOWED TO
REMAIN PER IEBC. NEW HANDRAILS COMPLY WITH THE
STANDARD.
1014.4 HANDRAIL EXTENSIONS:
EXISTING HANDRAILS NOT MODIFIED BY WORK AND ALLOWED TO
REMAIN PER IEBC. NEW HANDRAILS COMPLY WITH THE
STANDARD.
1014.7 CLEARANCE:
EXISTING HANDRAILS NOT MODIFIED BY WORK AND ALLOWED TO
REMAIN PER IEBC. NEW HANDRAILS COMPLY WITH THE
STANDARD.
1016.2 EGRESS THROUGH INTERVENING SPACES:
SEE CODE PLANS. SOME EGRESS PATHS IN BUILDING PASS
THROUGH VESTIBULES OR ADJACENT ROOMS THAT ARE
ACCESSORY TO ONE OR THE OTHER.
1017.2 [EXIT ACCESS TRAVEL DISTANCE] LIMITATIONS:
SEE CODE PLANS FOR EXIT ACCESS TRAVEL DISTANCE.
1017.3 MEASUREMENT:
SEE CODE PLANS FOR EXIT ACCESS TRAVEL DISTANCE.
1018.5 AISLES IN OTHER THAN ASSEMBLY SPACES AND GROUPS B AND M:
SEE TABLE 1020.3 FOR CORRIDOR AND AISLE WIDTH
REQUIREMENTS.
1019.1 [EXIT ACCESS STAIRWAYS] GENERAL:
EXISTING INTERIOR AND EXTERIOR EXIT STAIR NOT MODIFIED BY
PROJECT. NEW EXTERIOR RAMP IS FULLY EXTERIOR TO BUILDING.
1019.3 OCCUPANCIES OTHER THAN GROUPS I-2 AND I-3:
EXISTING STAIRWAY CONNECTS ONLY TWO ADJACENT STORIES.
NO SHAFT ENCLOSURE PROVIDED PER EXCEPTION 1.
1020 CORRIDORS:
STANDARDS APPLY TO NEW CORRIDORS.
1020.2 [CORRIDORS] CONSTRUCTION:
NEW CORRIDORS PROVIDED WITH 0-HR FIRE-RESISTANCE RATING
PER TABLE AS CORRIDORS SERVE FEWER THAN 30 OCCUPANTS.
1020.3 WIDTH AND CAPACITY:
SEE ARCHITECTURAL DRAWINGS. NEW CORRIDORS HAVE WIDTHS
MEETING OR EXCEEDING MINIMUM WIDTH.
TABLE 1006.2.1: SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY
(NONSPRINKLERED)
GROUP: MAX OCC LOAD OCC MAX COMMON PATH OF
OF SPACE EGRESS TRAVEL DISTANCE (FT)
B 49 1-30 100
>30 75 F 49 1-30 75
>30 75 S 29 1-30 100
>30 75 U 49 1-30 75
>30 75
TABLE 403.1: MIN NUMBER OF REQUIRED PLUMBING FIXTURES
GROUP: OCC WC WC U U LAV LAV DF DF
REQ'D M/W ALLOWED M REQ'D M/W REQ'D
LEVEL 1: 33
B 3 1 PER 25 < 50 0.1/0.1 2/3RD MAX 0.0 1 PER 40 <80 0.0/0.0 1 PER 100 0.0
F-1 16 1 PER 100 0.1/0.1 2/3RD MAX 0.1 1 PER 100 0.1/0.1 1 PER 400 0.0
S-1 14 1 PER 100 0.1/0.1 2/3RD MAX 0.1 1 PER 100 0.1/0.1 1 PER 1000 0.0
LEVEL 1 TOTAL: 0.3/0.3 0.2 0.2/0.2 0.0
LEVEL 2: 26
B 26 1 PER 25 < 50 0.5/0.5 2/3RD MAX 0.4 1 PER 40 <80 0.3/0.3 1 PER 100 0.3
LEVEL 2 TOTAL: 0.5/0.5 0.3 0.3/0.3 0.3
LEVEL 1 TOTALS PROVIDED: 1/1 0 1/1 2
LEVEL 2 TOTALS PROVIDED: 1/1 0 1/1 2
OTHER: 1 SERVICE SINK REQUIRED
2018 UNIFORM PLUMBING CODE
TABLE 422.1 MINIMUM PLUMBING FIXTURES:
BUILDING DOES NOT CHANGE OCCCUPANCY OR MAKE CHANGES
TO NUMBER OF TOILET ROOMS PROVIDED. 2024 IPC TABLE 403.1 IS
THE MORE RESTRICTIVE CODE BUT EXISTING FACILITIES MEET
REQUIREMENTS.
UP
DN
DN
DN
A B C D E F G H J
SHOP
101A
17 OCC
STORAGE
1 OCC
MUD ROOM
3 OCC
COMPUTER
107A
STAIR
110 HERITAGE SECURE
ROOM
CORRIDOR
3 OCC
CORRIDOR
111A
4 OCC
MUD ROOM
101C
1 OCC
JAN
WOMEN
MEN
MECH
1748 SF
FACTORY F-1
54 SF
BUSINESS
151 SF
BUSINESS
13 SF
FACTORY F-1
4118 SF
STORAGE S-1
VEST
101B
GARAGE
4 OCC
717 SF
ACCESSORY UTILITY
.5
4 0 .8
3 0 .6
3.4
13 OCC
13 OCC
63 SF
STORAGE S-1
421 SF
BUSINESS
CAGE 1
101A.1
CAGE 2
101A.2
CAGE 3
101A.3
FIRE CACHE
0.6"
113 SF
STORAGE S-1
127 SF
STORAGE S-1
P.L.P.L.
DISTANCE TO
PROPERTY LINE
OPEN COVERED UNOCCUPIED BIKE STORAGE STRUCTURE
*2-A
*2-A
*2-A
*2-A
A B C D E F G H J
MECH
MEN
BREAK
2 OCC
WOMEN
GEN OFFICE
16 OCC
STAIR
OFFICE
1 OCC
LEO STORAGE
GEN OFFICE
2 OCC
GEN OFFICE
1 OCC
3722 SF
BUSINESS
42 SF
BUSINESS
DISPATCH
2 OCC
.6
.6
298 SF
ACCESSORY S-1
96 SF
ACCESSORY S-1
19 SF
ACCESSORY S-1
154'
CODE LEGEND
EXIT
GROUP B
COMMON PATH OF EGRESS
EXIT ACCESS TRAVEL DISTANCE
BEYOND COMMON PATH
F.E.*
68.4"
OCC
REQ'D CAPACITY 2-A
GROUP
S-1
GROUP
F-1
ACCESSORY
U
ACCESSORY
S-1
1/16" = 1'-0"
LEVEL 1 CODE PLAN
1/16" = 1'-0"
LEVEL 2 CODE PLAN
A K
SA
LAFO
ET
A
T S
T C E T I
H
CRA
LANOISSEFO
RP
DE
R
E T S I
G E
R
No. A-140412
JUSTIN M. SCANIO
TH49
07.26.2024
N
S T R
E E T S U
IT
E
A N
C H
O R
A G
E A
L A
S K
A
.5
.5
E
C I/
H y e r, I n c.
C H
E C
K E D
A
U T H
O R
P R
O J E C
T N
O
IS
S U
E D
A T E
R E V
IS
IO
N
FULL SIZE PRINTED ON 22 x 34
O W
N E R
C O
N T R
A C
T
G1.03
C O
D E P
L A
N S
-0
.0
C W
R J M
S
.2
.2
P E T E R
S B
U R
G O
F F
IC
E C
O N
S O
L
ID
A T
IO
N
W O
R K
C E N
T E R
R E P
L A
C E M
E N
T
H A
R R
IS
B U
IL
D
IN
G
C O
N S T R
U C
T
IO
N D
O C
U M
E N
T S
GENERAL NOTES
C.0
HA
RR
IS
B
UI
LD
IN
G
G
EN
ER
A
L N
O
TE
S, L
EG
EN
D, A
N D
A
BB
RE
VI
A
TIO
N S
N S
TR
EE
T, S
UI
TE
A N
C
HO
RA
G
E, A
LA
SK
A
7.
1.
E
CI
/H ye r, In c.
C
HE
C
KE
D
A
UT
HO
R:
PR
O
JE
C
T N
O
N
KH
D K
IS
SU
E D
A
TE
:7 .2
5.
RE
V
IS
IO
N
:N O
R
EV
IS
IO
N S
PN
D
EN
G
IN
EE
RS
, I
N C
W
6T
H A
V E
A N
C
HO
RA
G
E, A
K, FULL SIZE PRINTED ON 22 x 34
O W
N
ER
C O
N
TR
A C
T:
PE
TE
RS
BU
RG
O
FF
IC
E C
O N
SO
LI
D A
TIO
N
W
O
RK
C
EN
TE
R
RE
PL
A C
EM
EN
T
HA
RR
IS
B
UI
LD
IN
G C O
N
ST
RU
C
TIO
N
D O
C
UM
EN
TS
AKAF AL
TS
TA E O
49 TH
S
Douglas T. Kenley
CE-8176
REGISTERED PROFESSIONA L ENGINEER
EW
EW
EW
EW
EW
EW
EW
EW
ES
ES
MITKOF HIGHWAY
O
H P
O H
P O
H P
O H
P
S
SW
SW
SCOW BAY LOOP RD.
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
O H
P O
H P
O H
P
UG
P
UG
P
E E
T
AC
HARRIS
BUILDING
C.1
HA
RR
IS
B
UI
LD
IN
G
EX
IS
TIN
G
C O
N
DI
TIO
N
D
EM
O
LI
TIO
N P
LA
N
0 15 30 45 FT105
N S
TR
EE
T, S
UI
TE
A N
C
HO
RA
G
E, A
LA
SK
A
1.
E
CI
/H ye r, In c.
C
HE
C
KE
D
A
UT
HO
R:
PR
O
JE
C
T N
O
N
KH
D K
IS
SU
E D
A
TE
:7 .2
5.
RE
V
IS
IO
N
:N O
R
EV
IS
IO
N S
PN
D
EN
G
IN
EE
RS
, I
N C
W
6T
H A
V E
A N
C
HO
RA
G
E, A
K, FULL SIZE PRINTED ON 22 x 34
O W
N
ER
C O
N
TR
A C
T:
PE
TE
RS
BU
RG
O
FF
IC
E C
O N
SO
LI
D A
TIO
N
W
O
RK
C
EN
TE
R
RE
PL
A C
EM
EN
T
HA
RR
IS
B
UI
LD
IN
G C O
N
ST
RU
C
TIO
N
D O
C
UM
EN
TS
AK
AF AL
TS
TA E
O
49 TH
S
Douglas T. Kenley
EW
EW
EW
EW
EW
EW
EW
ES
ES
MITKOF HIGHWAY
O
H P
O H
P O
H P
O H
P
S
SW
SW
SCOW BAY LOOP RD.
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
O H
P O
H P
O H
P
UG
P
UG
P
E E
T
AC
HARRIS
BUILDING
C.2
HA
RR
IS
B
UI
LD
IN
G
S
ITE
P
LA
N
0 15 30 45 FT105
N S
TR
EE
T, S
UI
TE
A N
C
HO
RA
G
E, A
LA
SK
A
1.
E
CI
/H ye r, In c.
C
HE
C
KE
D
A
UT
HO
R:
PR
O
JE
C
T N
O
N
KH
D K
IS
SU
E D
A
TE
:7 .2
5.
RE
V
IS
IO
N
:N O
R
EV
IS
IO
N S
PN
D
EN
G
IN
EE
RS
, I
N C
W
6T
H A
V E
A N
C
HO
RA
G
E, A
K, FULL SIZE PRINTED ON 22 x 34
O W
N
ER
C O
N
TR
A C
T:
PE
TE
RS
BU
RG
O
FF
IC
E C
O N
SO
LI
D A
TIO
N
W
O
RK
C
EN
TE
R
RE
PL
A C
EM
EN
T
HA
RR
IS
B
UI
LD
IN
G C O
N
ST
RU
C
TIO
N
D O
C
UM
EN
TS
AK
AF AL
TS
TA E
O
49 TH
S
Douglas T. Kenley
EW
EW
EW
EW
EW
EW
EW
ES
ES
MITKOF HIGHWAY
O
H P
O H
P O
H P
O H
P
S
SW
SW
SCOW BAY LOOP RD.
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
O H
P O
H P
O H
P
UG
P
UG
P
E E
T
AC
HARRIS
BUILDING
C.3
PE
TE
RS
BU
RG
D
IS
TR
IC
T O
FF
IC
E G
RA
DI
N G
P
LA
N
N S
TR
EE
T, S
UI
TE
A N
C
HO
RA
G
E, A
LA
SK
A
1.
E
CI
/H ye r, In c.
C
HE
C
KE
D
A
UT
HO
R:
PR
O
JE
C
T N
O
N
KH
D K
IS
SU
E D
A
TE
:7 .2
5.
RE
V
IS
IO
N
:N O
R
EV
IS
IO
N S
PN
D
EN
G
IN
EE
RS
, I
N C
W
6T
H A
V E
A N
C
HO
RA
G
E, A
K, FULL SIZE PRINTED ON 22 x 34
O W
N
ER
C O
N
TR
A C
T:
PE
TE
RS
BU
RG
O
FF
IC
E C
O N
SO
LI
D A
TIO
N
W
O
RK
C
EN
TE
R
RE
PL
A C
EM
EN
T
HA
RR
IS
B
UI
LD
IN
G C O
N
ST
RU
C
TIO
N
D O
C
UM
EN
TS
AK
AF AL
TS
TA E
O
49 TH
S
Douglas T. Kenley
CE-8176
REGISTERED PROFESS IONA L ENGINEER
0 15 30 45 FT105
B
C.4
ABA CONCRETE PATHWAYA
C.4
CONCRETE PAVEMENT SECTION
C
C.4
UTILITY TRENCH SECTION
C.4
H A
RR
IS
B U
IL
D
IN
G
C
IV
IL
T
YP
IC
A L
SE
C
TI
O
N S
N S
TR
EE
T, S
U
IT
E
A
N C
H O
RA
G
E, A
LA
SK
A
1.
E
CI
/H ye r, In c.
C H
EC
KE
D
A U
TH
O
R:
PR
O
JE
C
T N
O
N
KH
D K
IS
SU
E D
A
TE
:7 .2
5.
RE
V
IS
IO
N
:N O
R
EV
IS
IO
N S
PN
D
E N
G
IN
EE
RS
, I N
C
W
6T H
A V
E A
N C
H O
RA
G
E, A
K, FULL SIZE PRINTED ON 22 x 34
O W
N
ER
C O
N
TR
A C
T:
PE
TE
RS
BU
RG
O
FF
IC
E C
O N
SO
LI
D A
TI
O
N
W O
RK
C
EN
TE
R
RE
PL
A
C
EM
EN
T
H A
RR
IS
B U
IL
D
IN
G C
O N
ST
RU
C
TI
O N
D O
C U
M
EN
TS
AKAF AL
TS
TA
E O
49 TH
S
Douglas T. Kenley
C.5
EXPANSION JOINT DETAIL (EJ)1
C.5
CONTROL JOINT DETAIL (CJ)
C.5
HA
RR
IS
B
UI
LD
IN
G
C
IV
IL
D
ET
A
IL
S
(1 O
F 2)
N S
TR
EE
T, S
UI
TE
A N
C
HO
RA
G
E, A
LA
SK
A
1.
E
CI
/H ye r, In c.
C
HE
C
KE
D
A
UT
HO
R:
PR
O
JE
C
T N
O
N
KH
D K
IS
SU
E D
A
TE
:7 .2
5.
RE
V
IS
IO
N
:N O
R
EV
IS
IO
N S
PN
D
EN
G
IN
EE
RS
, I
N C
W
6T
H A
V E
A N
C
HO
RA
G
E, A
K, FULL SIZE PRINTED ON 22 x 34
O W
N
ER
C O
N
TR
A C
T:
PE
TE
RS
BU
RG
O
FF
IC
E C
O N
SO
LI
D A
TIO
N
W
O
RK
C
EN
TE
R
RE
PL
A C
EM
EN
T
HA
RR
IS
B
UI
LD
IN
G C O
N
ST
RU
C
TIO
N
D O
C
UM
EN
TS
AKAF AL
TS
TA E O
49 TH
S
Douglas T. Kenley
C.6
CONCRETE WASHDOWN STATION DETAILS
CONCRETE WASHDOWN STATION
PLAN VIEW
CONCRETE WASHDOWN STATION
ELEVATION VIEW
C.6
HA
RR
IS
B
UI
LD
IN
G
C
IV
IL
D
ET
A
IL
S
(2 O
F 2)
N S
TR
EE
T, S
UI
TE
A N
C
HO
RA
G
E, A
LA
SK
A
1.
E
CI
/H ye r, In c.
C
HE
C
KE
D
A
UT
HO
R:
PR
O
JE
C
T N
O
N
KH
D K
IS
SU
E D
A
TE
:7 .2
5.
RE
V
IS
IO
N
:N O
R
EV
IS
IO
N S
PN
D
EN
G
IN
EE
RS
, I
N C
W
6T
H A
V E
A N
C
HO
RA
G
E, A
K, FULL SIZE PRINTED ON 22 x 34
O W
N
ER
C O
N
TR
A C
T:
PE
TE
RS
BU
RG
O
FF
IC
E C
O N
SO
LI
D A
TIO
N
W
O
RK
C
EN
TE
R
RE
PL
A C
EM
EN
T
HA
RR
IS
B
UI
LD
IN
G C O
N
ST
RU
C
TIO
N
D O
C
UM
EN
TS
AKAF AL
TS
TA E O
49 TH
S
Douglas T. Kenley
STRUCTURAL NOTES
GENERAL
THE CONTRACTOR MUST VERIFY AND COORDINATE ALL DIMENSIONS AMONG THE DRAWINGS
BEFORE STARTING ANY WORK OR FABRICATION. IN CASE OF DISCREPANCIES BETWEEN
DRAWINGS, SPECIFICATIONS, REFERENCE STANDARDS, SITE CONDITIONS OR GOVERNING
CODE, THE MORE STRINGENT REQUIREMENTS MUST GOVERN. CONTRACTOR MUST NOTIFY
THE ENGINEER OF DISCREPANCIES AND OBTAIN DIRECTION PRIOR TO PROCEEDING. NOTES
ON INDIVIDUAL STRUCTURAL DRAWINGS MUST TAKE PRIORITY OVER GENERAL STRUCTURAL
NOTES. NOTED DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT
SCALE DRAWINGS. TYPICAL DETAILS MAY NOT NECESSARILY BE INDICATED AS TYP ON THE
PLANS BUT MUST APPLY AS SHOWN OR DESCRIBED IN THE DETAILS.
ALL CONSTRUCTION MUST COMPLY WITH THE 2018 INTERNATIONAL BUILDING CODE (IBC) AS
AMENDED AND ADOPTED BY THE CITY OF PETERSBURG.
SAFETY - THE CONTRACTOR IS RESPONSIBLE FOR MEETING ALL FEDERAL, STATE AND
LOCAL SAFETY STANDARDS. THE CONTRACTOR IS IN CHARGE OF ALL SAFETY MATTERS ON
AND AROUND THE JOB SITE.
STRUCTURAL DESIGN DATA
RISK CATEGORY IS II IN ACCORDANCE WITH IBC SECTION 1604.5. STRUCTURAL DESIGN IS IN
ACCORDANCE WITH THE 2018 IBC AND 2018 IEBC AS AMENDED AND ADOPTED BY THE CITY
OF PETERSBURG. WORK UNDER THE IEBC IS CONSIDERED A LEVEL 2 ALTERATION. NO WORK
WILL INCREASE THE STRESS DUE TO GRAVITY OR LATERAL LOADS TO ANY EXISTING
MEMBER BY MORE THAN 10%.
THE STRUCTURE HAS BEEN ANALYZED ASSUMING THE FOLLOWING OPERATIONAL LOADS ON
THE COMPLETED STRUCTURES. CONTRACTOR IS RESPONSIBLE FOR TEMPORARY SHORING
AND BRACING DURING CONSTRUCTION.
LIVE LOADS: OFFICE AREAS = 50 PSF + 15 PSF PARTITION
1ST FLOOR CORRIDORS & EXITS = 100 PSF
CORRIDORS ABV 1ST FLOOR = 80 PSF
MECHANICAL ROOMS = 125 PSF
SNOW LOADS: GROUND SNOW (Pg) = 80 PSF Is=1.0, Ct=1.0, Ce=1.0 ROOF SNOW (Pf) = 40 PSF FLAT + DRIFT
WIND LOADS: BASIC WIND SPEED (3-SECOND GUST, Vult)=139 MPH, EXPOSURE C, INTERNAL PRESSURE GCpi=±0.55 (PARTIALLY ENCLOSED)
SEISMIC LOADS: SITE CLASS D-DEFAULT, SEISMIC DESIGN CATEGORY D,
SS=0.29, S1=0.275, SDS=0.30, Ie=1.0
FOUNDATIONS
FOUNDATIONS ARE DESIGNED FOR A MAXIMUM SOIL BEARING PRESSURE OF 1,500 PSF
UNDER SUSTAINED LOADING AND 2,500 PSF UNDER SHORT TERM LOADING.
FOUNDATION SOILS MUST BE PREPARED IN ACCORDANCE WITH THE IBC AND THE
GEOTECHNICAL INVESTIGATION REPORT DATED FEB 2004 BY PND, INC.
ALL ORGANIC, FROZEN, OR OTHER UNSUITABLE MATERIALS MUST BE REMOVED FROM SUB-
GRADE AND REPLACED WITH 12” MINIMUM COMPACTED GRANULAR NON-FROST
SUSCEPTIBLE (NFS) FILL. PIERS MUST BE FOUNDED UPON UNDISTURBED, NATURAL SUB-
GRADE.
SUB-GRADES BENEATH ANY NEW CONCRETE PADS OR SLABS MUST BE COMPACTED TO A
MINIMUM OF 95 PERCENT OF THE MAXIMUM DRY DENSITY AS MEASURED BY ASTM D1557.
BACKFILL AROUND AND ABOVE ALL FOUNDATION ELEMENTS MUST BE COMPACTED TO A
MINIMUM OF 90 PERCENT OF MAXIMUM DRY DENSITY.
DEFERRED DELEGATED DESIGN
THE FOLLOWING ITEMS ARE NOT INCLUDED IN THESE DRAWINGS AND REQUIRE
STRUCTURAL DESIGN TO BE FURNISHED BY THE CONTRACTOR:
1. SEISMIC ANCHORAGE OF MECHANICAL & ELECTRICAL EQUIPMENT
DRAWINGS AND CALCULATIONS FOR BUILDER-DESIGNED COMPONENTS, SEALED BY AN
ALASKA STATE REGISTERED PROFESSIONAL ENGINEER RESPONSIBLE FOR THE DESIGN,
MUST BE SUBMITTED TO THE ENGINEER FOR REVIEW FOR GENERAL CONFORMANCE TO THE
CONTRACT DOCUMENTS PRIOR TO SUBMITTING TO THE CITY OF PETERBURG BUILDING
DEPARTMENT FOR REVIEW. SUBMITTALS OF BUILDER-DESIGNED ITEMS MUST INCLUDE
LOCATIONS, MAGNITUDES, AND DIRECTIONS OF ALL FORCES TRANSFERRED TO THE
STRUCTURE. DEFERRED DELEGATED DESIGN SUBMITTALS MUST BE REVIEWED AND
APPROVED BY THE BUILDING DEPARTMENT OR AUTHORITY HAVING JURISDICTION PRIOR TO
INSTALLATION/CONSTRUCTION.
SUBMITTALS
THE CONTRACTOR MUST REVIEW, STAMP WITH THEIR APPROVAL, DATE AND SIGN ALL SHOP
DRAWINGS AND SUBMITTALS REQUIRED BY THE CONTRACT DRAWINGS PRIOR TO
SUBMITTAL TO THE ENGINEER. AT THE TIME OF SUBMISSION, THE CONTRACTOR MUST
INFORM THE ENGINEER IN WRITING OF ANY DEVIATION IN THE SHOP DRAWINGS FROM THE
REQUIREMENTS OF THE CONTRACT DRAWINGS. DIMENSIONS AND QUANTITIES ARE THE
CONTRACTOR'S RESPONSIBILITY AND WILL NOT BE REVIEWED.
STRUCTURAL CONCRETE
ALL CONCRETE CONSTRUCTION MUST CONFORM TO ACI 301, STANDARD SPECIFICATION FOR
STRUCTURAL CONCRETE, AS MODIFIED BY IBC SECTION 1905 AND LOCAL ADOPTED
AMENDMENTS.
ALL CAST-IN-PLACE CONCRETE:
1. EXPOSURE F2, S0, W0, C0 (ACI 318-14, 19.3.1.1)
2. MINIMUM 28-DAY COMPRESSIVE STRENGTH = 4,000 PSI
3. MAXIMUM AGGREGATE SIZE = 3/4"
4. MAXIMUM WATER-CEMENT RATIO = 0.45
5. MAXIMUM CHLORIDE ION CONTENT = 1.00%
6. TARGET AIR CONTENT = 6% (+/-1%), EXCEPT FOR TROWELED INTERIOR SLABS WHICH
MUST NOT EXCEED 3% AIR CONTENT.
7. PROVIDE BROOMED FINISH FOR EXTERIOR CONCRETE PADS.
CONCRETE MUST BE PROPORTIONED TO ACHIEVE A WORKABLE MIX THAT CAN BE PLACED
WITHOUT SEGREGATION OR EXCESS FREE SURFACE WATER.
APPLICABLE ASTM STANDARDS:
PORTLAND CEMENT = ASTM C150
AGGREGATE = ASTM C33, NORMAL WEIGHT
WATER = ASTM C1602
WATER REDUCING ADMIXTURE = ASTM C494, TYPE A
CONCRETE PLACED DURING COLD WEATHER MUST CONFORM TO ACI 306. ALL COLD
WEATHER CONCRETE AND CONCRETE EXPOSED TO WEATHER MUST CONTAIN AIR
ENTRAINMENT PER ACI 318-14 TABLE 19.3.3.1.
THE FOLLOWING MINIMUM CONCRETE COVER MUST BE PROVIDED FOR REINFORCEMENT
FOR CAST-IN-PLACE CONCRETE:
A. CONCRETE CAST AGAINST EARTH 3-INCHES
B. CONCRETE EXPOSED TO EARTH OR WEATHER
-#6 AND LARGER 2-INCHES
-#5 AND SMALLER 1½-INCHES
C. CONCRETE NOT EXPOSED TO EARTH OR WEATHER 3/4-INCH
ALL CONCRETE REINFORCING MUST BE DETAILED, FABRICATED, LABELED, SUPPORTED AND
SPACED IN FORMS AND SECURED IN PLACE IN ACCORDANCE WITH THE LATEST EDITIONS OF
ACI 315, ACI 318, CRSI MSP-1 AND ACI SP-66. DOWELS MUST MATCH SIZE AND NUMBER OF
MAIN REINFORCING.
TYPICAL REINFORCING BARS MUST BE ASTM A615, GRADE 60. LAP SPLICES MUST BE CLASS
B LAPS PER ACI (63 X BAR DIAMETER). LAP SPLICES MAY ALSO ACCOMPLISHED USING
MECHANICAL DEVICES THAT DEVELOP 125% OF THE STRENGTH OF THE REBAR.
ALL WELDED WIRE REINFORCEMENT (WWR) MUST CONFORM TO ASTM A185 OR ASTM A497.
USE 6x6-W1.4xW1.4 SHEETS WHERE INDICATED IN SLABS ON GRADE, SUPPORTED ON
APPROVED CHAIRS AND LAPPED 12-INCHES MINIMUM. FIBER REINFORCEMENT,
CONFORMING TO ASTM C1116, TYPE III MAY BE USED IN LIEU OF SLAB ON GRADE
REINFORCEMENT. USE RECOMMENDED DOSAGE OF MFR, MINIMUM OF 2.5 LB/CU. YD.
CHECKED SHOP DRAWINGS SHOWING REINFORCING DETAILS, INCLUDING STEEL SIZES,
SPACING AND PLACEMENT MUST BE SUBMITTED TO THE ENGINEER FOR REVIEW PRIOR TO
FABRICATION. SUBMIT MIX DESIGNS FOR REVIEW PRIOR TO USE.
EMBEDDED ITEMS (CONDUIT AND SLEEVES) MUST NOT BE EMBEDDED IN OR PASS THROUGH
CONCRETE WITHOUT APPROVAL. ALUMINUM ITEMS MUST NOT BE EMBEDDED IN CONCRETE.
SUBMIT CONDUIT LAYOUT AND EMBEDDED ITEM PLANS FOR REVIEW PRIOR TO PLACING
CONCRETE.
NON-SHRINK GROUT MUST BE NON-METALLIC, CONFORMING TO ASTM C1107.
POST-INSTALLED ANCHORS
INSTALLATION MUST CONFORM TO MANUFACTURER'S INSTRUCTIONS AND REQUIREMENTS
OF ICC-ES REPORT. ALL POST-INSTALLED ANCHORS MUST HAVE A CURRENT ICC-ES REPORT
AND BE AUTHORIZED FOR USE IN SEISMIC DESIGN CATEGORY D.
PERIODIC SPECIAL INSPECTION IS REQUIRED FOR ALL POST-INSTALLED ANCHORS, UON.
INSTALLATION OF ADHESIVE ANCHORS HORIZONTALLY OR UPWARDLY INCLINED MUST BE
PERFORMED BY ACI/CRSI CERTIFIED PERSONNEL ONLY AND REQUIRES CONTINUOUS
SPECIAL INSPECTION.
THREADED ROD MUST BE ASTM A36, UON (OR ISO898 CLASS 5.8), TENSILE STRENGTH OF 60
KSI MIN, AND GALVANIZED WHERE EXPOSED TO THE WEATHER.
HOLES MUST BE HAMMER DRILLED. EXISTING BASE MUST BE SCANNED PRIOR TO DRILLING
HOLES. EXISTING REBAR LOCATIONS MUST BE MARKED, AND NEW ANCHOR LOCATIONS
REVISED TO AVOID EXISTING REINFORCING. NO REINFORCING BARS MUST BE CUT TO
INSTALL ANCHORS. ALL DEFECTIVE ANCHOR HOLES MUST BE GROUTED AND A NEW HOLE
DRILLED A MINIMUM OF 3 BOLT DIAMETERS AWAY.
ADHESIVE ANCHORS FOR THREADED ROD AND REBAR MUST BE ONE OF THE FOLLOWING
(OR AN APPROVED EQUIVALENT):
-DEWALT “PURE110+” (ESR-3298)
-HILTI "HIT-HY 200 V3" (ESR-4868)
-EPCON "A7+" (ESR-3903)
-SIMPSON “SET-XP” (ESR-2508)
EXPANSION ANCHORS MUST BE ONE OF THE FOLLOWING (OR AN APPROVED EQUIVALENT):
-HILTI "KWIK BOLT TZ2" (ESR-4266)
-SIMPSON "STRONG-BOLT 2" (ESR-3037) – 1/4” anchors excluded -DEWALT “POWER-STUD+SD2” (ESR-2502) – 1/4” anchors excluded
SCREW ANCHORS IN CONCRETE MUST BE ONE OF THE FOLLOWING (OR AN APPROVED
EQUIVALENT):
-HILTI “KH-EZ” (ESR-3027)
-SIMPSON "TITEN HD" (ESR-2713)
-ITW "TAPCON+" (ESR-3699)
-DEWALT "SCREW-BOLT+" (ESR-3889)
POWER-ACTUATED FASTENERS (PAF) MUST BE 0.148-INCHES IN DIAMETER AND THE ANCHOR
TYPE AND POWER LOAD MUST BE SUITED TO THE MATERIAL BEING FASTENED AND THE
SUBSTRATE MATERIAL. PRODUCT MUST BE ITW RAMSET/RED HEAD (ESR-1799, 1955 OR 2579)
OR APPROVED EQUAL. SPECIAL INSPECTION IS NOT REQUIRED FOR PAF INSTALLATION.
STRUCTURAL STEEL
MATERIALS:
ALL SHAPES & PLATE: ASTM A36
BOLTS, WASHERS & NUTS: ASTM A307, F436 & A563
HARDENED WASHERS: ASTM F436
ANCHOR RODS: ASTM A36
ALL DETAILING, FABRICATION AND ERECTIONS MUST CONFORM TO AISC SPECIFICATIONS
AND CODES, LATEST EDITION.
ALL WELDING MUST BE DONE BY QUALIFIED WELDERS AND MUST CONFORM TO THE AWS
D1.1 AND D1.8, LATEST EDITIONS. ALL WELDING ELECTRODES MUST BE PROPERLY
CONDITIONED 70 KSI MINIMUM TENSILE STRENGTH, WITH DIFFUSED HYDROGEN LEVELS OF
16ml/g (H16) OR LESS IN ACCORDANCE WITH AWS A4.3.
SHOP WELDS NOT SPECIFIED: USE CONTINUOUS OR ALL-AROUND 3/16" FILLET WELDS.
THERE MUST BE NO FIELD CUTTING OF STRUCTURAL STEEL MEMBERS FOR THE WORK OF
OTHER TRADES WITHOUT THE PRIOR APPROVAL OF THE ENGINEER.
ALL STEEL MUST BE CLEANED BY METHODS COMPLYING WITH THE STEEL STRUCTURES
PAINTING COUNCIL METHOD SSPC-SP3, POWER TOOL CLEANING. REMOVE OIL, GREASE,
AND SIMILAR CONTAMINANTS.
STEEL EXPOSED TO WEATHER OR INDICATED AS GALVANIZED MUST BE HOT-DIP
GALVANIZED PER ASTM A123. TOUCH-UP AND REPAIR GALVANIZATION MUST CONFORM TO
ASTM A780. FASTENERS MUST COMPLY WITH ASTM A153.
COLD FORMED STEEL
COLD FORMED STEEL MUST MEET ASTM A1003 STRUCTURAL GRADE 50 TYPE H (Fy=50 KSI)
FOR 14 GAUGE (68 MIL) OR 16 GAUGE (54 MIL) MEMBERS AND ASTM A1003 STRUCTURAL
GRADE 33 TYPE H (Fy=33 KSI) FOR 18 GAUGE (43 MIL) AND LIGHTER MEMBERS.
ALL STRUCTURAL MEMBERS MUST BE DESIGNED PER THE AMERICAN IRON AND STEEL
INSTITUTE (AISI) "SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL
MEMBERS", LATEST EDITION.
USE ONLY ONE MANUFACTURER OF COLD FORMED JOIST THROUGHOUT THE WORK, UNLESS
OTHERWISE SHOWN ON THE DRAWINGS OR SPECIFICALLY APPROVED IN ADVANCE BY THE
ENGINEER. ACCEPTABLE JOIST MANUFACTURERS INCLUDE ANY MEMBER OF THE STEEL
STUD MANUFACTURER'S ASSOCIATION.
PROVIDE ALL ACCESSORIES INCLUDING TRACKS, CLIPS, WEB STIFFENERS, ANCHORS,
FASTENING DEVICES, RESILIENT CLIPS, AND OTHER ITEMS REQUIRED FOR A COMPLETE AND
PROPER INSTALLATION. INSTALL ALL ITEMS RECOMMENDED BY THE MANUFACTURER.
FASTENING OF COMPONENTS MUST BE WITH SELF-DRILLING SCREWS (ASTM C1513) OR
WELDS OF SUFFICIENT SIZE TO INSURE THE STRENGTH OF THE CONNECTION. WIRE TYING
OF COMPONENTS MUST NOT BE PERMITTED. ALL WELDS MUST BE TOUCHED UP WITH A
ZINC-RICH PAINT.
UNLESS OTHERWISE INDICATED:
1. STUD AND TRACK SECTIONS TO BE 33 MIL (20 GA).
2. TRACKS MUST BE CONNECTED WITH TWO #8 SCREWS OR PAF TO SUPPORTING
SUBSTRATE AT EACH STUD, OR AN EQUIVALENT EQUAL SPACING;
3. STUDS MUST BE CONNECTED TO TOP AND BOTTOM TRACKS WITH TWO #8 SCREWS,
ONE AT EACH FLANGE;
STRUCTURAL TIMBER
MATERIALS:
DIMENSIONAL LUMBER: HEM-FIR NO. 2 OR BETTER
GLUE-LAMINATED TIMBER: GRADE: DF/DF, 24F-V8; APPEARANCE: INDUSTRIAL GRADE
ENGINEERED LUMBER: 2.0E PSL (PARALLAM, 2900f)
ROOF SHEATHING: APA RATED SHEATHING, EXPOSURE 1, SPAN RATED 40/20,
NOMINAL THICKNESS: 5/8-INCH
WALL SHEATHING: APA RATED SHEATHING, EXPOSURE 1, SPAN RATED 32/16,
NOMINAL THICKNESS: 1/2-INCH
SHEATHING MUST BE USED IN ACCORDANCE WITH THE RECOMMENDATIONS OF APA, THE
ENGINEERED WOOD ASSOCIATION. PLACE NAILS 3/8-INCH FROM EDGE OF PANELS
INSTALL ROOF SHEATHING WITH THE LONG DIMENSION ACROSS SUPPORTS. STAGGER
ADJACENT PANELS 48-INCHES. ALLOW 1/8-INCH SPACING AT PANEL ENDS AND PANEL
EDGES, UNLESS OTHERWISE RECOMMENDED BY THE PANEL MANUFACTURER.
INSTALL WALL SHEATHING VERTICALLY OR HORIZONTALLY. ALLOW 1/8-INCH SPACING AT
PANEL ENDS AND PANEL EDGES, UNLESS OTHERWISE RECOMMENDED BY THE PANEL
MANUFACTURER.
ALL ROOF DIAPHRAGMS MUST BE NAILED:
PANEL EDGES: 10d NAILS AT 4-INCHES ON-CENTER INTERMEDIATE SUPPORTS: 10d @ 12-INCHES ON-CENTER
THERE MUST BE NO FIELD CUTTING OF STRUCTURAL TIMBER MEMBERS FOR THE WORK OF
OTHER TRADES WITHOUT THE PRIOR REVIEW OF THE ENGINEER.
ALL NAILS MUST BE COMMON WIRE SMOOTH SHANK NAILS, PER ASTM F1667, UNLESS NOTED
OTHERWISE. OTHER NAILS PER ESR-1539 ARE ALLOWED WITH NUMBER OR SPACING
ADJUSTMENTS. SUBMIT DEFERRED SUBMITTAL FOR ALTERNATE FASTENERS. NAILING MUST
CONFORM TO TABLE 2304.10.1 OF THE IBC.
NAILS MUST BE DRIVEN FLUSH; HEADS MUST NOT BE DRIVEN BEYOND TIMBER SURFACE.
STANDARD ASTM A307 BOLTS MUST BE USED IN STD HOLES. WASHERS MUST BE USED
UNDER ALL BOLT HEADS AND NUTS CONTACTING WOOD.
ALL AWW LUMBER MUST BE PRESSURE TREATED IN ACCORDANCE WITH AWPA U1
STANDARD:
CAT UC2 FOR INTERIOR CONST NOT IN CONTACT WITH GROUND
CAT UC3b FOR EXTERIOR CONST NOT IN CONTACT WITH GROUND CAT UC4a FOR ITEMS IN CONTACT WITH GROUND
MEMBERS MORE THAN 8-INCHES ABOVE ADJACENT GRADE NEED NOT HAVE THIS SPECIAL
PRESERVATIVE TREATMENT, UON. TIMBER FASTENERS USED TO FASTEN SILL PLATES MUST
BE HOT-DIP GALVANIZED, STAINLESS STEEL, SILICON BRONZE OR COPPER.
ALLOW A GAP OF 5/8-INCH BETWEEN THE TOP OF NON-BEARING PARTITIONS AND JOISTS
ABOVE. ALLOW THE JOISTS TO DEFLECT UNDER LIVE LOAD WITHOUT TOUCHING THE NON-
BEARING PARTITION.
PRE-MANUFACTURED HARDWARE MUST BE SIMPSON OR APPROVED EQUAL. FASTENERS
FOR METAL CONNECTORS MUST CONFORM TO MANUFACTURER’S RECOMMENDATIONS FOR
THE HIGHEST CAPACITY AVAILABLE FOR EACH CONNECTOR, UNLESS OTHERWISE NOTED.
EXTERIOR HARDWARE EXPOSED TO WEATHER MUST BE HOT DIP GALVANIZED.
SPECIAL INSPECTIONS AND TESTING
THE OWNER SHALL ENGAGE A SPECIAL INSPECTOR PER CHAPTER 17 OF THE IBC. SPECIAL
INSPECTION AND TESTING OF BUILDING STRUCTURE COMPONENTS SHALL BE AS OUTLINED
IN THE SPECIAL INSPECTIONS AND TESTING SCHEDULES. WHERE REQUIREMENTS OVERLAP,
THE MORE STRINGENT IS TO BE USED.
SPECIAL INSPECTION IS NOT REQUIRED FOR COMPONENTS FABRICATED IN AN AISC-
CERTIFIED SHOP APPROVED TO PERFORM SUCH WORK WITHOUT SPECIAL INSPECTION.
COPIES OF THE SPECIAL INSPECTION AND TEST REPORTS SHALL BE DISTRIBUTED TO THE
AHJ, THE GENERAL CONTRACTOR, THE ENGINEER OF RECORD, AND THE ARCHITECT OF
RECORD. REPORTS SHALL BE COMPLETED DAILY AND DISTRIBUTED ON A WEEKLY BASIS
AND SHALL BE DISTRIBUTED BY THE MONDAY FOLLOWING THE WEEK IN WHICH THE
INSPECTION OR TEST WAS COMPLETED. A COPY OF ALL SPECIAL INSPECTION REPORTS,
DEFICIENCIES, AND CORRECTIVE ACTIONS SHALL BE MAINTAINED AT THE JOB SITE.
STRUCTURAL OBSERVATIONS ARE NOT REQUIRED FOR THIS PROJECT.
CONTRACTOR SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE OWNER
AND THE AHJ, IN ACCORDANCE WITH IBC 1704.4. THE STATEMENT SHALL ACKNOWLEDGE
AWARENESS OF THE SPECIAL REQUIREMENTS OF THE QUALITY ASSURANCE PLAN;
ACKNOWLEDGE THAT CONTROL WILL BE EXERCISED TO OBTAIN CONFORMANCE WITH THE
CONSTRUCTION DOCUMENTS; IDENTIFY PROCEDURES FOR EXERCISING CONTROL; THE
METHOD AND FREQUENCY OF REPORTING, AND THE DISTRIBUTION OF REPORTS; AND
IDENTIFY PERSONS THAT WILL EXERCISE CONTROL AND THEIR QUALIFICATIONS.
A K
AF AL
T S
TA
E O
49 TH
S
MICHAEL R FIERRO
No. SE 14017
R
EG IS T ER E D P R O F E S S IO NA L ENG IN
EER
NOTIF…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .