10 14 00.20.pdf

PDF 30 KB Posted

Attached to
WWYK250063 - INSTALL REACT VII FACILITY, B9001, POST V19
Solicitation number
FA813727R0002
Issued by

About this file

This is a technical specification document for interior signage at Tinker Air Force Base, Oklahoma, dated April 2019 (Section 10 14 00.20).

The specification establishes comprehensive requirements for the design, fabrication, and installation of interior signage systems. Sign types include standard room identification signs, directional signage, changeable message strip signs, stair signage, building directories, and pressure-sensitive letters. Standard room signs must be constructed from laminated thermosetting Type MP plastic (three-ply melamine with phenolic core) with aluminum square-style corner end caps and frameless design. Changeable message strip signs require clear sleeves accepting paper or plastic inserts, along with software and paper for text creation. All signage must incorporate ADA-ABA compliant fonts, tactile letters, symbols, and Braille in accordance with 36 CFR 1191. Character proportions and mounting heights must conform to accessibility guidelines. Building directories shall be non-illuminated units with aluminum frames featuring anodized finishes and glazed doors meeting ASTM C1036 specifications (Type 1, Class 1, Quality 3, minimum 1/8 inch thickness). Aluminum components must conform to ASTM B221 (extrusions) and ASTM B209 (plate/sheet), with anodic coatings meeting AA DAF45 standards at 0.4 mil minimum thickness or organic coatings per AAMA 2604 at 1.2 mils minimum. Installation requires manufacturer's instructions compliance, proper anchorage methods based on substrate type, and submission of six copies of operating and maintenance instructions. The contractor must provide a two-year warranty against defective workmanship and materials from delivery date and submit samples, detail drawings, installation procedures, and warranty documentation for government approval.

View the file

Other files

File Type Posted
250063_ATT 13_Prebid RFI Responses Round 1.pdf PDF
250063_ATT 8_Liquidated Damages.pdf PDF
250063_ATT 4_ODS.pdf PDF
2026 TAFB Mechanical Standard_signed.pdf PDF
2026 TAFB FIRE PROTECTION STANDARD.pdf PDF
SOW Att 04_Automated Casting Cell.pdf PDF
SOW Att 02a_Controlled Area Training.pptx PPTX presentation
250063_ATT 10_Submittal Register.pdf PDF
23 00 00.pdf PDF
08 11 13.pdf PDF
08 33 23.pdf PDF
10 22 13.pdf PDF
10 44 16.pdf PDF
07 21 16.pdf PDF
00 71 00.pdf PDF
01 33 00.pdf PDF
01 50 00.pdf PDF
ufc_3_260_01_2019_c1.pdf PDF
EM_385-1-1.pdf PDF
dafi21-101_afmcsup_afmcgm2023-01.pdf PDF
ufc_3_601_02_2021.pdf PDF
tinkerafbi13-204.pdf PDF
afman32-7003.pdf PDF
afman91-203_oc-alcsup.pdf PDF
afi48-104.pdf PDF
dodio-2000.16v1_afi10-245-o.pdf PDF
007200_Attch7b_Monthly Hazardous Usage Report.pdf PDF
007200_Attch9_EMS Awareness Training.pdf PDF
JOIST SPECIAL INSPECTIONS.xlsx XLSX spreadsheet
250063_ Redline A-502.pdf PDF
HE05IN_Dimension_Drawing.pdf PDF
lrad331965pd_spec.pdf PDF
ELECTRICAL COMBINED.pdf PDF
4500-MUG.pdf PDF
220042 As Built Drawings.pdf PDF
Solicitation - FA813727R0002.pdf PDF
2026 TAFB Electrical Standard - Signed.pdf PDF
SOW Att 02c_Controlled Area Training - Certificate.pdf PDF
250063_ATT 3_RMDF.pdf PDF
23 05 15.pdf PDF
23 09 13.pdf PDF
09 90 00.pdf PDF
26 20 00.pdf PDF
08 51 23.pdf PDF
07 92 00.pdf PDF
07 14 00.pdf PDF
08 71 00.pdf PDF
23 05 93.pdf PDF
07 84 00.pdf PDF
03 01 00.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Ti nker AFB, OK TAFB Techni cal Spr ci f i cat i ons 2019

SECTI ON 10 14 00. 20

I NTERI OR SI GNAGE

PART 1 GENERAL

1. 1 REFERENCES

The publ i cat i ons l i s t ed bel ow f or m a par t of t hi s speci f i cat i on t o t he ext ent r ef er enced. The publ i cat i ons ar e r ef er r ed t o i n t he t ext by basi c desi gnat i on onl y.

ALUMI NUM ASSOCI ATI ON ( AA)

AA DAF45 ( 2003; Reaf f i r med 2009) Desi gnat i on Syst em f or Al umi num Fi ni shes

AA PK- 1 ( 2015) Pi nk Sheet s: Desi gnat i ons and Chemi cal Composi t i on Li mi t s f or Al umi num Al l oys i n t he For m of Cast i ngs & I ngot

AMERI CAN ARCHI TECTURAL MANUFACTURERS ASSOCI ATI ON ( AAMA)

AAMA 2604 ( 2013) Vol unt ar y Speci f i cat i on, Per f or mance Requi r ement s and Test Pr ocedur es f or Hi gh Per f or mance Or gani c Coat i ngs on Al umi num Ext r usi ons and Panel s

AMERI CAN NATI ONAL STANDARDS I NSTI TUTE ( ANSI )

ANSI Z97. 1 ( 2015) Saf et y Gl azi ng Mat er i al s Used i n Bui l di ngs - Saf et y Per f or mance Speci f i cat i ons and Met hods of Test

AMERI CAN WELDI NG SOCI ETY ( AWS)

AWS D1. 2/ D1. 2M ( 2014) St r uct ur al Wel di ng Code - Al umi num

ASTM I NTERNATI ONAL ( ASTM)

ASTM B209 ( 2014) St andar d Speci f i cat i on f or Al umi num and Al umi num- Al l oy Sheet and Pl at e

ASTM B209M ( 2014) St andar d Speci f i cat i on f or Al umi num and Al umi num- Al l oy Sheet and Pl at e ( Met r i c)

ASTM B221 ( 2014) St andar d Speci f i cat i on f or Al umi num and Al umi num- Al l oy Ext r uded Bar s, Rods, Wi r e, Pr of i l es, and Tubes

ASTM B221M ( 2013) St andar d Speci f i cat i on f or Al umi num and Al umi num- Al l oy Ext r uded Bar s, Rods, Wi r e, Pr of i l es, and Tubes ( Met r i c)

ASTM C1036 ( 2016) St andar d Speci f i cat i on f or Fl at Glass

Apr i l 2019 Page 1 SECTI ON 10 14 00. 20

ASTM D635 ( 2014) St andar d Test Met hod f or Rat e of Bur ni ng and/ or Ext ent and Ti me of Bur ni ng of Sel f - Suppor t i ng Pl ast i cs i n a Hor i zont al Posi t i on

I NTERNATI ONAL CODE COUNCI L ( I CC)

I CC A117. 1 COMM ( 2009) St andar d And Comment ar y and Usabl e Bui l di ngs and Faci l i t i es

NATI ONAL FI RE PROTECTI ON ASSOCI ATI ON ( NFPA)

NFPA 101 ( 2015; ERTA 2015) Li f e Saf et y Code

NFPA 70 ( 2017) Nat i onal El ect r i cal Code

U. S. NATI ONAL ARCHI VES AND RECORDS ADMI NI STRATI ON ( NARA)

36 CFR 1191 Amer i cans wi t h Di sabi l i t i es Act ( ADA) Accessi bi l i t y Gui del i nes f or Bui l di ngs and Faci l i t i es; Ar chi t ect ur al Bar r i er s Act ( ABA) Accessi bi l i t y Gui del i nes

1. 2 SUSTAI NABI LI TY REPORTI NG

Mat er i al s i n t hi s t echni cal speci f i cat i on may cont r i but e t owar ds cont r act compl i ance wi t h sust ai nabi l i t y r equi r ement s. See Sect i on 01 33 29 SUSTAI NABI LI TY REPORTI NG f or pr oj ect cer t i f i cat i on l ocal / r egi onal mat er i al s, r ecycl ed cont ent and document at i on r equi r ement s.

1. 3 SUBMITTALS

Gover nment appr oval i s r equi r ed f or submi t t al s wi t h a " G" desi gnat i on;

submi t t al s not havi ng a " G" desi gnat i on ar e f or Cont r act or Qual i t y Cont r ol appr oval . Submi t t he f ol l owi ng i n accor dance wi t h Sect i on 01 33 00

SUBMI TTAL PROCEDURES:

SD- 02 Shop Dr awi ngs

Det ai l Dr awi ngs; G

SD- 03 Pr oduct Dat a

I nst al l at i on; G War r ant y; G

SD- 04 Sampl es

I nt er i or Si gnage; G Sof t war e; G

SD- 10 Oper at i on and Mai nt enance Dat a

Appr oved Manuf act ur er ' s I nst r uct i ons; G Pr ot ect i on and Cl eani ng; G

Apr i l 2019 Page 2 SECTI ON 10 14 00. 20

1. 4 QUALI TY ASSURANCE

1. 4. 1 Samples

Submi t i nt er i or s i gnage sampl es of each of t he f ol l owi ng si gn t ypes showi ng t ypi cal qual i t y, wor kmanshi p and col or : Di r ect i onal s i gn, St andar d Room si gn, Changeabl e message st r i p s i gn, conf er ence r oom si gn. The sampl es may be i nst al l ed i n t he wor k, pr ovi ded each sampl e i s i dent i f i ed and l ocat i on r ecor ded.

1. 4. 2 Det ai l Dr awi ngs

Submi t det ai l dr awi ngs showi ng el evat i ons of each t ype of s i gn, di mensi ons, det ai l s and met hods of mount i ng or anchor i ng, mount i ng hei ght , shape and t hi ckness of mat er i al s, and det ai l s of const r uct i on. I ncl ude a schedul e showi ng t he l ocat i on, each si gn t ype, and message.

1. 5 DELI VERY, STORAGE, AND HANDLI NG

Mat er i al s shal l be packaged t o pr event damage and det er i or at i on dur i ng shi pment , handl i ng, st or age and i nst al l at i on. Pr oduct shal l be del i ver ed t o t he j obsi t e i n manuf act ur er ' s or i gi nal packagi ng and st or ed i n a c l ean, dr y ar ea i n accor dance wi t h manuf act ur er ' s i nst r uct i ons.

1. 6 WARRANTY

War r ant t he i nt er i or s i gnage f or a per i od of 2 year s agai nst def ect i ve wor kmanshi p and mat er i al . War r ant i es shal l be s i gned by t he aut hor i zed r epr esent at i ve of t he manuf act ur er . Submi t war r ant y accompani ed by t he document aut hent i cat i ng t he s i gner as an aut hor i zed r epr esent at i ve of t he guar ant or . Guar ant ee t hat t he s i gnage pr oduct s and t he i nst al l at i on ar e f r ee f r om any def ect s i n mat er i al and wor kmanshi p f r om t he dat e of delivery.

PART 2 PRODUCTS

2. 1 STANDARD PRODUCTS

Si gns, pl aques, di r ect or i es, and di mensi onal l et t er s shal l be t he st andar d pr oduct of a manuf act ur er r egul ar l y engaged i n t he manuf act ur e of such pr oduct s t hat essent i al l y dupl i cat e s i gns t hat have been i n sat i sf act or y use at l east 2 year s pr i or t o bi d openi ng. Obt ai n s i gnage f r om a si ngl e manuf act ur er wi t h edges and cor ner s of f i ni shed l et t er f or ms and gr aphi cs t r ue and cl ean.

2. 2 ROOM I DENTI FI CATI ON/ DI RECTI ONAL SI GNAGE SYSTEM

2. 2. 1 St andar d Room Si gns

Si gns shal l consi st of l ami nat ed t her moset t i ng Type MP pl ast i c ( t hr ee- pl y mel ami ne pl ast i c l ami nat e wi t h phenol i c cor e) and shal l conf or m t o t he following:

a.

b. End caps shal l be al umi numsquar e st y l e cor ner s.

c. Uni t s shal l be f r amel ess. Cor ner s of s i gns shal l be squar ed .

Apr i l 2019 Page 3 SECTI ON 10 14 00. 20

2. 2. 2 Changeabl e Message St r i p Si gns

Changeabl e message st r i p s i gns shal l be of same const r uct i on as st andar d r oom si gns t o i ncl ude a c l ear s l eeve t hat wi l l accept a paper or pl ast i c i nser t i dent i f y i ng changeabl e t ext . Pr ovi de paper and sof t war e f or cr eat i ng t ext and symbol s f or comput er s i dent i f i ed by owner f or Owner pr oduct i on of paper i nser t s af t er pr oj ect compl et i on. Sl i di ng i nser t s or s l i de knobs t hat s l i de hor i zont al l y exposi ng di f f er ent gr aphi c i nf or mat i on shal l be pr ovi ded as i dent i f i ed i n t he s i gnage pl acement schedul e and drawings.

2. 2. 3 Type of Mount i ng For Si gns

Pr ovi de ext r uded al umi num br acket s f or hangi ng, pr oj ect i ng, and doubl e- si ded si gns. Mount i ng f or f r amed, hangi ng, and pr oj ect i ng s i gns shal l be by mechani cal f ast ener s. Sur f ace mount ed si gns shal l be mount ed wi t h 1/ 16 i nch t hi ck c l osed cel l v i nyl f oam wi t h adhesi ve backi ng.

Adhesi ve shal l be t r anspar ent , l ong agi ng, hi gh t ech f or mul at i on on t wo si des of t he v i nyl f oam.

2. 2. 4 Char act er Pr opor t i ons and Hei ght s

Let t er s and number s on si gns conf or m t o 36 CFR 1191.

2. 2. 5 Tact i l e Let t er s, Symbol s and Br ai l l e

Rai sed l et t er s and number s on si gns shal l conf or m t o 36 CFR 1191.

2. 3 STAI R SI GNAGE

Pr ovi de si gns on st ai r s ser vi ng t hr ee or mor e st or i es wi t h speci al s i gnage wi t hi n t he encl osur e at each f l oor l andi ng conf or mi ng t o NFPA 101.

I ndi cat e t he f l oor l evel , t he t er mi nus of t he t op and bot t om of t he st ai r encl osur e, and t he i dent i f i cat i on of t he st ai r encl osur e. Al so, st at e t he f l oor l evel of , and t he di r ect i on t o, exi t di schar ge. Locat e t he s i gnage i nsi de t he encl osur e i n a posi t i on t hat i s v i s i bl e when t he door i s i n t he open or c l osed posi t i on and i nst al l i n conf or mance wi t h 36 CFR 1191. The f l oor l evel desi gnat i on shal l al so be t act i l e i n accor dance wi t h

I CC A117. 1 COMM.

2. 4 BUI LDI NG DI RECTORI ES

Bui l di ng di r ect or i es shal l be l obby di r ect or i es or f l oor di r ect or i es, and shal l be pr ovi ded wi t h a changeabl e di r ect or y l i s t i ng consi st i ng of t he ar eas, of f i ces and per sonnel l ocat ed wi t hi n t he f aci l i t y . Di mensi ons, det ai l s, and mat er i al s of s i gn and message cont ent shal l be as shown on t he dr awi ngs.

2. 4. 1 Header Panel

Header panel shal l have backgr ound met al t o mat ch f r ame.

2. 4. 2 Doors

2. 4. 2. 1 Door Gl azi ng

Door gl azi ng shal l be i n accor dance wi t h ASTM C1036, Type 1, Cl ass 1, Qual i t y 3, mi ni mum 1/ 8 i nch t hi ck.

Apr i l 2019 Page 4 SECTI ON 10 14 00. 20

2. 4. 2. 2 Door Const r uct i on

Ext r uded al umi num door f r ame shal l be of same f i ni sh as sur r oundi ng f r ame. Cor ner s shal l be mi t er ed , r ei nf or ced, and assembl ed wi t h conceal ed f ast ener s. Hi nges shal l be st andar d wi t h t he manuf act ur er , i n f i ni sh t o mat ch f r ames and t r i m. Gl azi ng shal l be set i n f r ame wi t h r esi l i ent gl azi ng channel s.

2. 4. 2. 3 Door Locks

Door l ocks shal l be manuf act ur er ' s st andar d, and shal l be keyed al i ke.

Pr ovi de t wo set s of keys.

2. 4. 3 Fabrication

Ext r uded al umi num f r ames and t r i m shal l be assembl ed wi t h cor ner s r ei nf or ced and mi t er ed t o a hai r l i ne f i t , wi t h no exposed f ast ener s.

2. 4. 4 Non- I l l umi nat ed Uni t

Di r ect or y shal l consi st of a non- i l l umi nat ed uni t wi t h scr een pr i nt ed or v i nyl copy appl i ed t o acr yl i c, met al , or hi gh- pr essur e pl ast i c l ami nat e st r i ps. Desi gn of uni t shal l be as shown i n t he dr awi ngs.

2. 4. 4. 1 Construction

The di r ect or y shal l be const r uct ed of an al umi num 2 i nch deep f r ame wi t h anodi zed f i ni sh. Uni t shal l be sur f ace mount ed. Uni t shal l have a 3_f our ____ i nch hi gh header . Uni t shal l have a 3/ 8cur e met hod. Door f r ame shal l mat ch di r ect or y mat er i al and f i ni sh.

2. 4. 4. 2 Message St r i ps

Message st r i ps shal l be updat abl e by user . Message st r i ps shal l be s i zed i n accor dance wi t h manuf act ur er ' s st andar d. Let t er s and number s shal l be pr ovi ded i n accor dance wi t h t he dr awi ngs.

2. 5 PRESSURE SENSI TI VE LETTERS

2. 5. 1 Fabrication

Ensur e t hat v i nyl l et t er edges and cor ner s of f i ni shed l et t er f or ms and gr aphi cs ar e t r ue and cl ean. Do not use l et t er f or ms and gr aphi cs wi t h r ounded posi t i ve or negat i ve cor ner s, ni cked, cut , or r agged edges.

2. 5. 2 Size

Let t er s i ze: as i ndi cat ed .

2. 6 ALUMI NUM ALLOY PRODUCTS

Al umi num ext r usi ons shal l be at l east 1/ 8 i nch t hi ck, and al umi num pl at e or sheet shal l be at l east 0. 0508 i nch t hi ck. Ext r usi ons shal l conf or m t o ASTM B221; pl at e and sheet shal l conf or m t o ASTM B209. Wher e anodi c coat i ngs ar e speci f i ed, al l oy shal l conf or m t o AA PK- 1 al l oy desi gnat i on

514. 0. Exposed anodi zed al umi num f i ni shes shal l be as shown. Wel di ng f or al umi num pr oduct s shal l conf or m t o AWS D1. 2/ D1. 2M.

Apr i l 2019 Page 5 SECTI ON 10 14 00. 20

2. 7 ANODI C COATI NG

Anodi zed f i ni sh shal l conf or m t o AA DAF45 as f ol l ows:

a. Cl ear ( nat ur al ) desi gnat i on AA- M10- C22- A31, Ar chi t ect ur al Cl ass I I 0. 4 mi l or t hi cker .

b. I nt egr al col or anodi zed desi gnat i on AA- M10- C22- A32, Ar chi t ect ur al Cl ass

0. 4 t o 0. 7 mi l .

c. El ect r ol yt i cal l y deposi t ed col or - anodi zed desi gnat i on AA- M10- C22- A34, Ar chi t ect ur al Cl ass I I 0. 4 t o 0. 7 mi l .

2. 8 ORGANI C COATI NG

Or gani c coat i ng shal l conf or m t o AAMA 2604, wi t h t ot al dr y f i l m t hi ckness not l ess t han 1. 2 mi l s.

2. 9 FABRI CATI ON AND MANUFACTURE

2. 9. 1 Fact or y Wor kmanshi p

Hol es f or bol t s and scr ews shal l be dr i l l ed or punched. Dr i l l i ng and punchi ng shal l pr oduce cl ean, t r ue l i nes and sur f aces. Exposed sur f aces of wor k shal l have a smoot h f i ni sh and exposed r i vet i ng shal l be f l ush.

Fast eni ngs shal l be conceal ed wher e pr act i cabl e.

2. 9. 2 Di ssi mi l ar Mat er i al s

Wher e di ssi mi l ar met al s ar e i n cont act , t he sur f aces wi l l be pr ot ect ed t o pr event gal vani c or cor r osi ve act i on.

2. 10 COLOR, FI NI SH, AND CONTRAST

Col or shal l be as i ndi cat ed . Fi ni sh of al l s i gns shal l be eggshel l , mat t e, or ot her non- gl ar e f i ni sh as r equi r ed i n handi capped- accessi bl e buildings.

2. 11 TYPEFACE

ADA- ABA compl i ant f ont f or Room Si gns.

PART 3 EXECUTI ON

3. 1 INSTALLATION

Si gns shal l be i nst al l ed pl umb and t r ue and i n accor dance wi t h appr oved manuf act ur er ' s i nst r uct i ons at l ocat i ons shown on t he det ai l dr awi ngs .

Submi t s i x copi es of oper at i ng i nst r uct i ons out l i ni ng t he st ep- by- st ep pr ocedur es r equi r ed f or syst em oper at i on. The i nst r uct i ons shal l i ncl ude si mpl i f i ed di agr ams f or t he syst em as i nst al l ed, t he manuf act ur er ' s name, model number , ser vi ce manual , par t s l i s t , and br i ef descr i pt i on of al l equi pment and t hei r basi c oper at i ng f eat ur es. Each set shal l be per manent l y bound and shal l have a har d cover . The f ol l owi ng i dent i f i cat i on shal l be i nscr i bed on t he cover s: t he wor ds " OPERATI NG AND MAI NTENANCE I NSTRUCTI ONS" , name and l ocat i on of t he f aci l i t y , name of t he Cont r act or , and cont r act number . Mount i ng hei ght and mount i ng l ocat i on shal l conf or m t o 36 CFR 1191. Requi r ed bl ocki ng shal l be i nst al l ed.

Si gns on door s or ot her sur f aces shal l not be i nst al l ed unt i l f i ni shes on

Apr i l 2019 Page 6 SECTI ON 10 14 00. 20 such sur f aces have been i nst al l ed. Si gns i nst al l ed on gl ass sur f aces shal l be i nst al l ed wi t h mat chi ng bl ank back- up pl at es i n accor dance wi t h manuf act ur er ' s i nst r uct i ons. I l l umi nat ed si gnage shal l be i n conf or mance wi t h t he r equi r ement s of Sect i on 26 51 00 I NTERI OR LI GHTI NG.

3. 1. 1 Anchorage

Anchor age shal l be i n accor dance wi t h appr oved manuf act ur er ' s i nst r uct i ons. Anchor age not ot her wi se speci f i ed or shown shal l i ncl ude sl ot t ed i nser t s, expansi on shi el ds, and powder - dr i ven f ast ener s when appr oved f or concr et e; t oggl e bol t s and t hr ough bol t s f or masonr y; machi ne car r i age bol t s f or st eel ; l ag bol t s and scr ews f or wood. Exposed anchor and f ast ener mat er i al s shal l be compat i bl e wi t h met al t o whi ch appl i ed and shal l have mat chi ng col or and f i ni sh.

a. Si gns mount ed t o pai nt ed gypsum boar d sur f aces shal l be r emovabl e f or pai nt i ng mai nt enance.

b. Mount s i gns mount ed t o l ay- i n cei l i ng gr i ds wi t h c l i p connect i ons t o cei l i ng t ees.

c. I nst al l s i gns mount ed on met al sur f aces wi t h magnet i c t ape.

d. I nst al l s i gns mount ed on f abr i c sur f aces wi t h hook and l oop t ape or pi n mount .

3. 1. 2 Pr ot ect i on and Cl eani ng

Pr ot ect t he wor k agai nst damage dur i ng const r uct i on. Har dwar e and el ect r i cal equi pment shal l be adj ust ed f or pr oper oper at i on. Gl ass, f r ames, and ot her s i gn sur f aces shal l be c l eaned at compl et i on of s i gn i nst al l at i on i n accor dance wi t h t he manuf act ur er ' s appr oved i nst r uct i ons and t he r equi r ement s of Sect i on 01 78 23 OPERATI ON AND MAI NTENANCE DATA, Package 1. Submi t s i x copi es of mai nt enance i nst r uct i ons l i s t i ng r out i ne pr ocedur es, r epai r s, and gui des.

- - End of Sect i on - -

Apr i l 2019 Page 7 SECTI ON 10 14 00. 20

File details come from the government source that posted it. Updated .