12'-0"
(E) CMU ENCLOSURE
8x8x16 CMU
ENCLOSURE
T/SLAB TO MATCH (E)
ENCLOSURE T/SLAB,
SLOPE SLAB 1% TO (E)
SIDEWALK
A
A
(E) CONCRETE SLAB
CONTROL JOINT
SEE 3
(E) SIDEWALK
2" PREMOLDED JOINT
FILLER BETWEEN (E)
AND NEW CONCRETE
2" PREMOLDED JOINT
FILLER BETWEEN (E)
AND NEW CMU
#4 AT 16"
EACH WAY
B A R Ø
T E N S
IO
N L A P S P L
IC
E
1-#6 CONT TOP
SLAB ON GRADE OR PAVEMENT
SEE CIVIL DRAWINGS
12" MIN
C L R
C L R
A T
#4 AT 16" EACH
WAY
#4 AT 16" VERT
#4 AT 16" HORIZ
8x8x16 CMU WALL REINFORCED AS
SHOWN AND GROUTED SOLID, SPLIT
FACE, TAN TO MATCH (E), W/WATER
REPELLENT
CENTER
#5 AT 16" ALTERNATE HOOK
DIRECTION EVERY OTHER BAR
4" CONCRETE SLAB-ON-GRADE
REINFORCED WITH #3 AT 18",
ABOVE 8" GRAVEL, TURNDOWN
PER
2'-2"
ADD'L #5
BAR VERT
HORIZ BARADD'L #5
BAR VERT
OPEN END BLOCKS
THROUGHOUT
NOTES:
1. PLACE VERT REBAR
AT CL OF WALL UNO
CORNER INTERSECTIONPLAN
#6 BARS
VERT UNO
VERT REBAR
2 STD BOND BM
BLOCKS AT 4" HIGH
UNITS ONLY
HORIZ WALL
REBAR
BAR POSITIONER
OR EQUAL AT 200
db MAX FOR
POSITIONING VERT
REBAR
1/2" MIN CLR
PROVIDE CLEANOUT
AT BOTTOM COURSE
FOR GROUT POURS
GREATER THAN 5'-0"
JAMB OR WALL
END PLAN
BOND BEAM BLOCK- SECTION (AT
ALL HORIZ REBAR)
2" PREMOLDED JOINT FILLER
2'-10"
ALTERNATE BARS
CONT THRU JOINT -
OTHER BARS CUT 3"
SHORT OF JOINT EACH
SIDE
8" MIN, 14" MAX
NOTES:
1. SAWCUT JOINTS WITHIN 12 HOURS AFTER PLACING CONCRETE
2. REMOVE VOID FORM AFTER PLACING CONCRETE.
3. DEPRESS REINFORCEMENT IN VICINITY OF SAWCUT TO AVOID DAMAGING
REINFORCEMENT
CONTRACTION JOINT
T /4
S E E
N O T E S
T
8"
2- #3 CONT
P E R P L A N
REINF PER PLAN
TERMINATE HORIZ
BARS W/STD HOOKS
(E) CONSTRUCTION
2" PREMOLDED
JOINT FILLER
F O R O F F
IC
IA
L U S E O N L Y
IN
F O R M A T
IO
N S A F E G U A R D
IN
G I S R E Q U
IR
E D
T h e i n fo rm a ti o n c o n ta in e d o n t h is d ra w in g s h a ll re m a in u n d e r th e c o n tr o l o f th e o ri g in a ti n g r e q u e s te r o r a g e n c y o r it s s u c c e s s o r in f u n c ti o n a t a ll ti m e s I n fo rm a ti o n s a fe g u a rd in g i s t h e r e s p o n s ib ili ty o f th e i n d iv id u a l/ a g e n c y /c o m p a n y re q u e s ti n g t h e d a ta a n d t a k in g o ri g in a l p o s s e s s io n o f th is d ra w in g R e le a s e /d is c lo s u re o f d a ta t o a n y p a rt y b e y o n d t h e o ri g in a l re q u e s t a n d i n te n d e d u s e i s p ro h ib it e d N o p u b lic p u b lic a ti o n o f th e d a ta b y a n y m e a n s o r a n a ly s e s t h e re o f is a u th o ri z e d U p o n c o m p le ti o n o f th e u s e o f th e d a ta c o n ta in e d o n t h is d ra w in g th e d ra w in g m u s t b e r e tu rn e d o r d e s tr o y e d D ir e c t a n y q u e s ti o n s t o t h e E n g in e e ri n g S u p p o rt E le m e n t, C E S /C E C B a t -6 -4 In fo rm a ti o n s a fe g u a rd in g r e q u ir e m e n ts a re p e r A F M A N -1 A F I -3 D O D R e g .1 a n d E x e c u ti v e O rd e r w h e n a p p lic a b le
D O N O T D U P L
IC
A T E T H
IS
D R A W
IN
G O R T H E D A T A C O N T A
IN
E D O N I T
FOUNDATION PLAN
SCALE: 1/4"=1'-0"
A
SECTION
SCALE: 1"=1'-0"
TYPICAL MASONRY WALL DETAILS
SCALE: NOT TO SCALE
CONTROL JOINT
SCALE: NOT TO SCALE
SLAB TURNDOWN
SCALE: NOT TO SCALE
1'-0" TYP
PERMISSIBLE CONSTRUCTION JOINT
#4 AT 12" EACH WAY
ROUGHEN JOINT 1/4" MIN. AMPLITUDE
EXIST. CONCRETE WITH HIT HY 150 EPOXY BY HILTI OR
#4 AT 12" EACH WAY. DRILL AND EMBED INTO
APPROVED EQUAL. EMBED BAR 4" INTO EXIST. SLAB
EXIST. SLAB ON GRADE
AT EXISTING SLAB
AT NEW SLAB
NOTES:
1. PAD SIZE SHALL BE THE MINIMUM INDICATED ON DRAWINGS OR MINIMUM TO
PROVIDE 6" CLEAR TO EMBEDDED ANCHORS OR AS INDICATED BY THE
MANUFACTURER AND APPROVED BY THE ENGINEER.
2. POST-INSTALLED ANCHORS TO BE PER DETAIL 2 ON SHEET M-502. FILL ALL
MOUNTING HOLES WITH ANCHORS.
3. EQUIPMENT BASES SHALL BE INSTALLED LEVEL UNLESS NOTED OTHERWISE.
TYPICAL CONCRETE EQUIPMENT PAD
SCALE: NOT TO SCALE