081387C-C501.pdf

PDF 185 KB Posted

Attached to
XUMU 08-3187C - Replace Existing HVAC/Install Climate Control, B 8290
Solicitation number
081387C
Issued by

About this file

Attachment 3 - Drawings

View the file

Other files

File Type Posted
XUMU 08-1387C - Request for Information.docx DOCX document
SITE VISIT ATTENDANCE SHEET.pdf PDF
Revised SOW-B8290-HVAC Replacement 02 Aug 2010.docx DOCX document
081387C-E301.pdf PDF
081387C-S001.pdf PDF
081387C-C201.pdf PDF
081387C-M103.pdf PDF
081387C-E401.pdf PDF
Amendment 2 - RFP Letter XUMU 08-1387B - 4 Aug 2010.pdf PDF
081387C-M601.pdf PDF
081387C-M401.pdf PDF
081387C-G001.pdf PDF
081387C-M201.pdf PDF
081387C-S101.pdf PDF
081387C-S002.pdf PDF
Attachment 5 - Wage Determination.docx DOCX document
01010 03Jun08.pdf PDF
01440 Contractor QC.pdf PDF
081387C-M101.pdf PDF
Spec Cover Sheet.pdf PDF
081387C-E001.pdf PDF
Bldg 8290 Vandenberg Specs 7-14-09.pdf PDF
081387C-M602.pdf PDF
081387C-M502.pdf PDF
081387C-E101.pdf PDF
01000 General Requirements.pdf PDF
081387C-M501.pdf PDF
000110 Table of Contents.pdf PDF
081387C-M202.pdf PDF
081387C-M603.pdf PDF
081387C-M104.pdf PDF
081387C-E501.pdf PDF
081387C-E102.pdf PDF
081387C-M001.pdf PDF
081387C-E201.pdf PDF
Revised Bid Sheet XUMU 08-1387C AFCESA SATOC 02 Aug 2010.xlsx XLSX spreadsheet
081387C-C101.pdf PDF
081387C-M102.pdf PDF
081387C-C001.pdf PDF
Show all 39

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PORTLAND CEMENT CONCRETE

GROOVED, SAWCUT OR PLASTIC FILLED

COMPACTED SUBGRADE

1/8" TOOLED EDGE NON-EXTRUDED JOINT FILLER1

4"

16"

1"

16"

COMPACTED SUBGRADE

CONTRACTION JOINT

EXPANSION JOINT

COMPACTED SUBGRADE

COMPACTED TO 90% OF

MAX DENSITY

GRADE

1'-0" SEE PLAN FOR WIDTH

CROSS SLOPE, MAX 14"/FT

MIN.18"/FT

SIDEWALK SECTION - TYPICAL

PIPE

SIZE

TRENCH WIDTH

(X) (Y) (Z)

MIN. MAX.

BEDDING

(MIN.)

COVER

(MIN.)

2",4"&6"

8"

10"

12"

18"

20"

22"

24"

24"

26"

28"

30"

3"

3"

4"

4"

6"

6"

6"

6"

1.

2.

BEDDING AND

COVER, (SEE

SPECIFICATIONS)

BACKFILL MATERIAL

AS REQUIRED FOR

TRENCH TYPE (SEE

SPECS.)

WIDER TRENCHES SHALL REQUIRE HIGHER

STRENGTH PIPE AND/OR SPECIAL BEDDING.

DIFFERING TRENCH WIDTHS REQUIRE PRIOR

APPROVAL OF OWNER'S REPRESENTATIVE.

PIPE BEDDING DETAILS

TRENCH DIMENSION CHART

NOTES:

TRENCH DIMENSION CHART

FOR MULTIPLE PIPE TRENCHES SEPARATE PIPES BY 12"

FOR CONDUITS IN PIPE TRENCHES SEPARATE BY 6"

3" CROWN TO

ALLOW FOR

SETTLING, TYP

#12 COPPER

TRACER WIRE

SEE TRENCH

DIMENSION CHART

FOR COVER AND

BEDDING

REQUIREMENTS

CROWN AS DIRECTED

BY ENGINEER.

PROVIDE DRAINAGE AS

NECESSARY TO DRAIN.

REPLACE TOPSOIL

AND RESEED AS PER

SPECIFICATIONS.

CLEAN UP ALL GRAVEL

AND SPOILS.

1.

2.

3.

4.

MECH. TAMPED

10" CLASS 2

AGGREGATE BASE

95% RELATIVE

COMPACTION

SEE TRENCH

DIMENSION CHART

FOR COVER AND

BEDDING REQ'MTS.

90% RELATIVE

COMPACTION

#12 COPPER

TRACER WIRE

NEW P.C.C. SLAB

ON GRADE. DOWEL

INTO (E) SIDEWALK.

MATCH (E) DIMS

ORIGINAL

CUT LINE

TRENCH WIDTH

PLUS 12" (MIN.)

NOTES:

NOTES:

LANDSCAPED AREAS

SIDEWALKS

X

CLASS "C"

BACKFILL

(SEE SPECS)

85% R.C.

Z

Y

EXISTING GROUND

CLASS "B"

BACKFILL

NOTES:

1. WIDER TRENCHES MAY REQUIRE HIGHER STRENGTH PIPE AND/OR SPECIAL BEDDING.

2. DIFFERING TRENCH WIDTHS REQUIRE PRIOR APPROVAL OF ENGINEER.

3. IN UNSTABLE SOILS INCREASE THE TRENCH WIDTH TO 5 PIPE DIAMETERS FOR PVC

PIPE.

NOTE: SEE FOUNDATION PLAN

FOR FLOOR JOINT LOCATIONS

CUT 50% OF

REINF BARS

AT JOINT

SEE CONTRACTION JOINT

FOR ADDITIONAL INFO NOT

NOTED

GREASE THIS

SIDE OF DOWEL

BOND BREAKER

WOOD CRACK INDUCER

4" WIDE SAWCUT, FILL W/SEALANT

8"Øx18" LONG SMOOTH

DOWELS AT MID-DEPTH

OF SLAB AT 12"

8" RADIUS TOOLED EDGE, FILL

W/SEALANT

2" TYP

1"

1" 3"

2"

(X)

(Y)

(Z)

CONTRACTION JOINT

CONSTRUCTION JOINT

NOTE: JOINT SPACING. MATCH EXISTING SIDEWALK CONTRACTION INTERVALS.

PROVIDE EXPANSION JOINTS WHERE NEW SIDEWALK ABUTS EXISTING SIDEWALK.

F O R O F F

IC

IA

L U S E O N L Y

IN

F O R M A T

IO

N S A F E G U A R D

IN

G I S R E Q U

IR

E D

T h e i n fo rm a ti o n c o n ta in e d o n t h is d ra w in g s h a ll re m a in u n d e r th e c o n tr o l o f th e o ri g in a ti n g r e q u e s te r o r a g e n c y o r it s s u c c e s s o r in f u n c ti o n a t a ll ti m e s I n fo rm a ti o n s a fe g u a rd in g i s t h e r e s p o n s ib ili ty o f th e i n d iv id u a l/ a g e n c y /c o m p a n y re q u e s ti n g t h e d a ta a n d t a k in g o ri g in a l p o s s e s s io n o f th is d ra w in g R e le a s e /d is c lo s u re o f d a ta t o a n y p a rt y b e y o n d t h e o ri g in a l re q u e s t a n d i n te n d e d u s e i s p ro h ib it e d N o p u b lic p u b lic a ti o n o f th e d a ta b y a n y m e a n s o r a n a ly s e s t h e re o f is a u th o ri z e d U p o n c o m p le ti o n o f th e u s e o f th e d a ta c o n ta in e d o n t h is d ra w in g th e d ra w in g m u s t b e r e tu rn e d o r d e s tr o y e d D ir e c t a n y q u e s ti o n s t o t h e E n g in e e ri n g S u p p o rt E le m e n t, C E S /C E C B a t -6 -4 In fo rm a ti o n s a fe g u a rd in g r e q u ir e m e n ts a re p e r A F M A N -1 A F I -3 D O D R e g .1 a n d E x e c u ti v e O rd e r w h e n a p p lic a b le

D O N O T D U P L

IC

A T E T H

IS

D R A W

IN

G O R T H E D A T A C O N T A

IN

E D O N I T

1 CONCRETE JOINT DETAILS NOT TO SCALE 3 SIDEWALK DETAILS NOT TO SCALE

4 TRENCH DETAILS NOT TO SCALE

2 CONCRETE JOINT DETAILS NOT TO SCALE

5 PIPE BEDDING DETAIL NOT TO SCALE

081387C-C501.dwg
Layout 1