081387C-C101.pdf

PDF 174 KB Posted

Attached to
XUMU 08-3187C - Replace Existing HVAC/Install Climate Control, B 8290
Solicitation number
081387C
Issued by

About this file

Attachment 3 - Drawings

View the file

Other files

File Type Posted
XUMU 08-1387C - Request for Information.docx DOCX document
SITE VISIT ATTENDANCE SHEET.pdf PDF
Revised SOW-B8290-HVAC Replacement 02 Aug 2010.docx DOCX document
081387C-E301.pdf PDF
081387C-S001.pdf PDF
081387C-C201.pdf PDF
081387C-M103.pdf PDF
081387C-E401.pdf PDF
Amendment 2 - RFP Letter XUMU 08-1387B - 4 Aug 2010.pdf PDF
081387C-M601.pdf PDF
081387C-M401.pdf PDF
081387C-G001.pdf PDF
081387C-M201.pdf PDF
081387C-S101.pdf PDF
081387C-S002.pdf PDF
Attachment 5 - Wage Determination.docx DOCX document
01010 03Jun08.pdf PDF
01440 Contractor QC.pdf PDF
081387C-M101.pdf PDF
Spec Cover Sheet.pdf PDF
081387C-E001.pdf PDF
Bldg 8290 Vandenberg Specs 7-14-09.pdf PDF
081387C-M602.pdf PDF
081387C-M502.pdf PDF
081387C-E101.pdf PDF
081387C-C501.pdf PDF
01000 General Requirements.pdf PDF
081387C-M501.pdf PDF
000110 Table of Contents.pdf PDF
081387C-M202.pdf PDF
081387C-M603.pdf PDF
081387C-M104.pdf PDF
081387C-E501.pdf PDF
081387C-E102.pdf PDF
081387C-M001.pdf PDF
081387C-E201.pdf PDF
Revised Bid Sheet XUMU 08-1387C AFCESA SATOC 02 Aug 2010.xlsx XLSX spreadsheet
081387C-M102.pdf PDF
081387C-C001.pdf PDF
Show all 39

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

(N)12'x20' CMU ENCLOSURE

SEE STRUCTURAL PLANS FOR DETAILS

SEE STRUCTURAL PLAN FOR P.C.C. EQUIPMENT PAD

REPAIR SIDEWALK AT TRENCH CUT TO

ORIGINAL CONDITION AS

NECESSARY-DOWEL INTO (E)SIDEWALK

AT JOINS.

SEE C-501±

5'

COMM.

ELEC.

ELEC.

CAUTION!

(E) UNDERGROUND

GAS LINES

(N)8" DIA. CHILLED WATER SUPPLY(1)

AND RETURN(1) LINES. MAINTAIN 2'

COVER MIN.

SEE PLUMBING PLAN FOR CONNECTION

TO CHILLER AND BUILDING INTERIOR

PIPE LOCATION.

(E) GAS LINES

COMM.

ELEC.

ELEC.

CAUTION!

(E) UNDERGROUND

GAS LINES

(N)DECORATIVE ROCK TO MATCH

(E)LAVA ROCK 2"-4" DIA.

±70 S.F.

(N)2"x6" REDWOOD HEADER. INSTALL

FLUSH TO FINISH GRADE.

REPAIR LAWN TO

MATCH (E)LAWN

±72 S.F.

PRESERVE AND

PROTECT (E)TREE

REPAIR LAWN AT TRENCH TO ORIGINAL

CONDITION.

PRESERVE AND

PROTECT (E)TREE

COMM.

ELEC.

ELEC.

CAUTION!

(E) UNDERGROUND

GAS LINES

CONFORM

CONFORM

CONFORM

(N)EQUIPMENT PAD ELEVATION TO

MATCH (E) PAD ELEVATION

F.F.=450.05 (PER AS-BUILT)

SIDEWALK REPAIR

CONFORM TO (E)SIDEWALK

ELEVATION

NEW LAWN AREA SHALL CONFORM TO

(E)LAWN AND (E)BACK OF CURB ELEVATIONS

COMM.

ELEC.

ELEC.

CAUTION!

(E) UNDERGROUND

GAS LINES

LAWN REPAIR - CONFORM TO (E)

LAWN ELEVATION

0 20'10'

CIVIL SITE PLAN

SCALE: 1/10"=1'-0"

N

0 20'10'

CIVIL GRADING PLAN

SCALE: 1/10"=1'-0"

N

0 20'10'

CIVIL UTILITIES PLAN

SCALE: 1/10"=1'-0"

N

0 20'10'

LANDSCAPE SITE PLAN

SCALE: 1/10"=1'-0"

N

F O R O F F

IC

IA

L U S E O N L Y

IN

F O R M A T

IO

N S A F E G U A R D

IN

G I S R E Q U

IR

E D

T h e i n fo rm a ti o n c o n ta in e d o n t h is d ra w in g s h a ll re m a in u n d e r th e c o n tr o l o f th e o ri g in a ti n g r e q u e s te r o r a g e n c y o r it s s u c c e s s o r in f u n c ti o n a t a ll ti m e s I n fo rm a ti o n s a fe g u a rd in g i s t h e r e s p o n s ib ili ty o f th e i n d iv id u a l/ a g e n c y /c o m p a n y re q u e s ti n g t h e d a ta a n d t a k in g o ri g in a l p o s s e s s io n o f th is d ra w in g R e le a s e /d is c lo s u re o f d a ta t o a n y p a rt y b e y o n d t h e o ri g in a l re q u e s t a n d i n te n d e d u s e i s p ro h ib it e d N o p u b lic p u b lic a ti o n o f th e d a ta b y a n y m e a n s o r a n a ly s e s t h e re o f is a u th o ri z e d U p o n c o m p le ti o n o f th e u s e o f th e d a ta c o n ta in e d o n t h is d ra w in g th e d ra w in g m u s t b e r e tu rn e d o r d e s tr o y e d D ir e c t a n y q u e s ti o n s t o t h e E n g in e e ri n g S u p p o rt E le m e n t, C

E S /C E C B a t -6 -4 In fo rm a ti o n s a fe g u a rd in g r e q u ir e m e n ts a re p e r A F M A N -1 A F I -3 D O D R e g .1 a n d E x e c u ti v e O rd e r w h e n a p p lic a b le

D O N O T D U P L

IC

A T E T H

IS

D R A W

IN

G O R T H E D A T A C O N T A

IN

E D O N I T

081387C-C101.dwg