081387C-M202.pdf

PDF 127 KB Posted

Attached to
XUMU 08-3187C - Replace Existing HVAC/Install Climate Control, B 8290
Solicitation number
081387C
Issued by

About this file

Attachment 3 - Drawings

View the file

Other files

File Type Posted
XUMU 08-1387C - Request for Information.docx DOCX document
SITE VISIT ATTENDANCE SHEET.pdf PDF
Revised SOW-B8290-HVAC Replacement 02 Aug 2010.docx DOCX document
081387C-E301.pdf PDF
081387C-S001.pdf PDF
081387C-C201.pdf PDF
081387C-M103.pdf PDF
081387C-E401.pdf PDF
Amendment 2 - RFP Letter XUMU 08-1387B - 4 Aug 2010.pdf PDF
081387C-M601.pdf PDF
081387C-M401.pdf PDF
081387C-G001.pdf PDF
081387C-M201.pdf PDF
081387C-S101.pdf PDF
081387C-S002.pdf PDF
Attachment 5 - Wage Determination.docx DOCX document
01010 03Jun08.pdf PDF
01440 Contractor QC.pdf PDF
081387C-M101.pdf PDF
Spec Cover Sheet.pdf PDF
081387C-E001.pdf PDF
Bldg 8290 Vandenberg Specs 7-14-09.pdf PDF
081387C-M602.pdf PDF
081387C-M502.pdf PDF
081387C-E101.pdf PDF
081387C-C501.pdf PDF
01000 General Requirements.pdf PDF
081387C-M501.pdf PDF
000110 Table of Contents.pdf PDF
081387C-M603.pdf PDF
081387C-M104.pdf PDF
081387C-E501.pdf PDF
081387C-E102.pdf PDF
081387C-M001.pdf PDF
081387C-E201.pdf PDF
Revised Bid Sheet XUMU 08-1387C AFCESA SATOC 02 Aug 2010.xlsx XLSX spreadsheet
081387C-C101.pdf PDF
081387C-M102.pdf PDF
081387C-C001.pdf PDF
Show all 39

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FC

FC

FC

FC

FC

FC

FC

FC

FC

FC

FC

FC

FC

FC

FC

(E)

(E)

(E)

(E)

(E)(E)(E)

(E)

(E) (E)

FC

(E)

(E)(E)

(E)

(E)

(E)

DEMOLISH EXISTING DUCTWORK

TO EXTENT SHOWN.

FC

(E)

EXISTING DUCTWORK TO REMAIN. SEE M103 AND

M104 FOR POC WITH NEW DUCTWORK (TYP).

DEMOLISH (E) HWS/HWR TO EXTENT SHOWN.

EXISTING HWS/HWR TO REMAIN. SEE M103 AND

M104 FOR POC WITH NEW HWS/HWR (TYP.).

F O R O F F

IC

IA

L U S E O N L Y

IN

F O R M A T

IO

N S A F E G U A R D

IN

G I S R E Q U

IR

E D

T h e i n fo rm a ti o n c o n ta in e d o n t h is d ra w in g s h a ll re m a in u n d e r th e c o n tr o l o f th e o ri g in a ti n g r e q u e s te r o r a g e n c y o r it s s u c c e s s o r in f u n c ti o n a t a ll ti m e s I n fo rm a ti o n s a fe g u a rd in g i s t h e r e s p o n s ib ili ty o f th e i n d iv id u a l/ a g e n c y /c o m p a n y re q u e s ti n g t h e d a ta a n d t a k in g o ri g in a l p o s s e s s io n o f th is d ra w in g R e le a s e /d is c lo s u re o f d a ta t o a n y p a rt y b e y o n d t h e o ri g in a l re q u e s t a n d i n te n d e d u s e i s p ro h ib it e d

N o p u b lic p u b lic a ti o n o f th e d a ta b y a n y m e a n s o r a n a ly s e s t h e re o f is a u th o ri z e d U p o n c o m p le ti o n o f th e u s e o f th e d a ta c o n ta in e d o n t h is d ra w in g th e d ra w in g m u s t b e r e tu rn e d o r d e s tr o y e d

D ir e c t a n y q u e s ti o n s t o t h e

E n g in e e ri n g

S u p p o rt E le m e n t, C

E S

/C E

C B a t

-6

-4

In fo rm a ti o n s a fe g u a rd in g r e q u ir e m e n ts a re p e r

A F

M A

N

-1

A

F I

-3

D

O D

R e g

.1 a n d

E x e c u ti v e O rd e r w h e n a p p lic a b le

D O N O T D U P L

IC

A T E T H

IS

D R A W

IN

G O R T H E D A T A C O N T A

IN

E D O N I T

M202

MECHANICAL SECOND FLOOR DEMOLITION PLAN

SCALE: 3/32"=1'-0"

SHEET GENERAL NOTES

1. REMOVE (E) THERMOSTAT, PNEUMATIC TUBING AND ASSOCIATED

APPURTENANCES.

2. REMOVE (E) FAN COIL, PNEUMATIC DAMPER ACTUATORS,

PNEUMATIC TUBING AND ASSOCIATED APPURTENANCES.

3. REMOVE (E) FAN COIL, CONTROL VALVES, PNEUMATIC TUBING, AND

ASSOCIATED APPURTENANCES.

1. CONTRACTOR TO VERIFY EXACT LOCATION OF EXISTING

EQUIPMENT.

2. CONTRACTOR TO REPAIR, PATCH, AND PAINT FLOORS, WALLS, AND

CEILINGS TO MATCH (E) FINISH.

DEMOLITION NOTES

081387C-M202.dwg