081387C-E001.pdf
PDF 143 KB Posted
- Solicitation number
- 081387C
About this file
Attachment 3 - Drawings
View the file
Other files
Show all 39
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F O R O F F
IC
IA
L U S E O N L Y
IN
F O R M A T
IO
N S A F E G U A R D
IN
G I S R E Q U
IR
E D
T h e i n fo rm a ti o n c o n ta in e d o n t h is d ra w in g s h a ll re m a in u n d e r th e c o n tr o l o f th e o ri g in a ti n g r e q u e s te r o r a g e n c y o r it s s u c c e s s o r in f u n c ti o n a t a ll ti m e s I n fo rm a ti o n s a fe g u a rd in g i s t h e r e s p o n s ib ili ty o f th e i n d iv id u a l/ a g e n c y /c o m p a n y re q u e s ti n g t h e d a ta a n d t a k in g o ri g in a l p o s s e s s io n o f th is d ra w in g R e le a s e /d is c lo s u re o f d a ta t o a n y p a rt y b e y o n d t h e o ri g in a l re q u e s t a n d i n te n d e d u s e i s p ro h ib it e d N o p u b lic p u b lic a ti o n o f th e d a ta b y a n y m e a n s o r a n a ly s e s t h e re o f is a u th o ri z e d U p o n c o m p le ti o n o f th e u s e o f th e d a ta c o n ta in e d o n t h is d ra w in g th e d ra w in g m u s t b e r e tu rn e d o r d e s tr o y e d D ir e c t a n y q u e s ti o n s t o t h e E n g in e e ri n g S u p p o rt E le m e n t, C E S /C E C B a t -6 -4 In fo rm a ti o n s a fe g u a rd in g r e q u ir e m e n ts a re p e r A F M A N -1 A F I -3 D O D R e g .1 a n d E x e c u ti v e O rd e r w h e n a p p lic a b le
D O N O T D U P L
IC
A T E T H
IS
D R A W
IN
G O R T H E D A T A C O N T A
IN
E D O N I T
ANNOTATION
SWITCHING
LIGHTING
CONDUIT
MAIN SWITCHBOARD
DISTRIBUTION PANEL BOARD
COMBINATION METER/MAIN SERVICE PANEL
BRANCH CIRCUIT PANEL BOARD, SURFACE OR FLUSH
MOUNTED
LIGHTING CONTROL PANEL
SIGNAL TERMINAL CABINET OR CONTROL PANEL
SURFACE OR FLUSH MOUNTED
SIGNAL TERMINAL BACKBOARD
CONCRETE UNDERGROUND HAND HOLE
(NUMBER DENOTES CHRISTY SIZE)
TRANSFORMER
EQUIPMENT
ELECTRICAL ABBREVIATIONSELECTRICAL SYMBOLS LEGEND
KEYNOTE
DEMOLITION NOTE
RACEWAY, FEEDER OR CIRCUIT DESIGNATION (SEE SCHEDULE)
ROOM NAME AND NUMBER (SEE ARCHITECTURAL DRAWINGS)
FIXTURE TYPE DESIGNATION
(SEE SCHEDULE)
DETAIL INDICATOR SECTION INDICATOR
MECHANICAL EQUIPMENT
DESIGNATION
(SEE SCHEDULE)
CCTV CAMERA, CEILING MOUNT
INTERCOM CALL IN SWITCH - MOUNTING HEIGHT: +48" AFF, UON
TELEPHONE OUTLET FOR WALL MOUNTED TELEPHONE
MOUNTING HEIGHT: +48" AFF UON
DATA OUTLET - MOUNTING HEIGHT: +18" AFF UON
TELEPHONE/DATA OUTLET, FLUSH TYPE UON
MOUNTING HEIGHT: +18" AFF UON
SURFACE RACEWAY WITH POWER AND TELEPHONE/DATA
RECEPTACLES AS INDICATED
CATV OUTLET - MOUNTING HEIGHT: +96" AFF UON
AUDIO/VIDEO OUTLET - MOUNTING HEIGHT: +18" AFF UON
DUPLEX RECEPTACLE, 15A 125V 2P 3W, GROUNDING TYPE,
MOUNTING HEIGHT: +18" AFF UON
DUPLEX RECEPTACLE - SPLIT WIRED, SWITCHED
DUPLEX RECEPTACLE - EMERGENCY POWER
DUPLEX RECEPTACLE - CEILING MOUNTED
FLOOR RECEPTACLE, 15A 125V 2P 3W, GROUNDING TYPE, FLUSH
TYPE UON
DOUBLE DUPLEX RECEPTACLE, 15A 125V 2P 3W, GROUNDING TYPE,
MOUNTING HEIGHT: +18" AFF UON
SINGLE RECEPTACLE, 20A 125V 2P 3W, GROUNDING TYPE,
MOUNTING HEIGHT: +18" AFF UON
SURFACE MOUNT DUPLEX AND FLEXIBLE CABLE/CONDUIT
CONNECTION TO FURNITURE SYSTEM
SPECIAL PURPOSE RECEPTACLE AS DESIGNATED
SEE 'SPECIAL SYMBOLS' ON EACH SHEET
DUAL SERVICE RECESSED FLOOR BOX WITH DUPLEX AND DATA
RECEPTACLES
JUNCTION BOX, CODE SIZED UON
JUNCTION BOX WITH FLEXIBLE CABLE/CONDUIT CONNECTION TO
FURNITURE SYSTEM
FLOOR JUNCTION BOX
DISCONNECT SWITCH - FUSED WHERE APPLICABLE
MOTOR STARTER, COMBINATION WITH DISCONNECT SWITCH
MOTOR STARTER OR CONTROLLER
MOTOR CONNECTION
CEILING EXHAUST FAN
WATER HEATER
POWER POLE: P=POWER, T=TELEPHONE,
D=DATA, C=COMBINATION
TEST PORT
GROUND ROD
GUY WIRE AND ANCHOR
THERMOSTAT (SEE MECHANICAL DRAWINGS)
MOUNTING HEIGHT: +48" AFF UON
BYPASS TIMER OR TIME SWITCH
PUSHBUTTON
LIGHTING CONTACTOR
(D) DEMOLITION
(E) EXISTING
(F) FUTURE
(N) NEW
A AMPERES
AC ALTERNATING CURRENT
AF AMP FRAME
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHU AIR HANDLING UNIT
AIC AMPS INTERRUPTING
CAPACITY
ANN ANNUNCIATOR
ATS AUTOMATIC TRANSFER SWITCH
AWG AMERICAN WIRE GAUGE
BAT BATTERY
BFG BELOW FINISH GRADE
CATV CABLE TELEVISION
C CONDUIT
CB CIRCUIT BREAKER
CCTV CLOSED CIRCUIT TELEVISION
CO CONDUIT ONLY
CPT CONTROL POWER
TRANSFORMER
CT CURRENT TRANSFORMER
CU COPPER
DC DIRECT CURRENT
EF EXHAUST FAN
EGU ENGINE GENERATOR UNIT
EM EMERGENCY
EMT ELECTRICAL METALLIC
CONDUIT
ENT ELECTRICAL NON-METALLIC
CONDUIT
EP EXPLOSION PROOF
FA FIRE ALARM
FACP FIRE ALARM CONTROL PANEL
FC FAN COIL
FU FUSE
GND GROUND
GFCI GROUND FAULT CIRCUIT
INTERRUPTER
GFI GROUND FAULT INTERRUPTER
GFR GROUND FAULT RELAY
HID HIGH INTENSITY DISCHARGE
HOA "HAND-OFF-AUTO" SWITCH
HP HORSEPOWER
HPS HIGH PRESSURE SODIUM
HVAC HEATING, VENTILATION &
AIR-CONDITIONING
CONDUIT INSTALLED ABOVE GRADE
CONDUIT INSTALLED UNDERGROUND OR UNDER SLAB
EXISTING CONDUIT
CONDUIT STUB-UP OR STUB-OUT
FLEXIBLE CONDUIT WHIP TO LIGHT FIXTURE OR EQUIPMENT
IG ISOLATED GROUND
JB JUNCTION BOX
KAIC KILO-AMPS INTERRUPTING
CAPACITY
KV KILOVOLT
KVA KILOVOLT-AMP
KW KILOWATT
KWH KILOWATT-HOUR
LPS LOW PRESSURE SODIUM
LV LOW VOLTAGE
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MCP MOTOR CIRCUIT PROTECTOR
MFR MANUFACTURER
MH METAL HALIDE
MLO MAIN LUGS ONLY
MV MEDIUM VOLTAGE
NIC NOT IN CONTRACT
NL NIGHT LIGHT
NTS NOT TO SCALE
OC ON CENTER
PA PUBLIC ADDRESS
PT POTENTIAL TRANSFORMER
PVC POLYVINYL CHLORIDE
PB PULL BOX, ELECTRICAL
RECPT RECEPTACLE, OUTLET
RGS RIGID GALVANIZED STEEL
RVSS REDUCED VOLTAGE SOFT
START
RTU REMOTE TERMINAL UNIT
TV TELEVISION MONITOR (SET)
TVSS TRANS. VOLT. SURGE
SUPPRESSOR
UF UNDER FLOOR
UG UNDERGROUND
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER
SUPPLY
V VOLT
VA VOLT-AMP
VFD VARIABLE FREQUENCY DRIVE
WP WEATHERPROOF
XFMR TRANSFORMER
FLUORESCENT FIXTURE, RECESSED
RECESSED DOWN LIGHT FIXTURE
RECESSED DIRECTIONAL FIXTURE (ARROW INDICATES AIMING)
FLUORESCENT FIXTURE, SURFACE MOUNTED
SURFACE, PENDANT OR OTHER FIXTURE
LARGE DIAMETER PENDANT, DEPICTING APPROXIMATE
DIAMETER
FLUORESCENT FIXTURE, WALL MOUNTED
WALL-MOUNTED HID, INCANDESCENT, OR COMPACT
FLUORESCENT FIXTURE
FLUORESCENT FIXTURE, PENDANT OR CABLE HUNG
LIGHT TRACK AND TRACK-MOUNTED FIXTURES
BATH FAN WITH INTEGRAL LIGHT
EXIT SIGN, SINGLE FACE WITH DIRECTIONAL ARROWS AS
INDICATED
EXIT SIGN, DOUBLE FACE WITH DIRECTIONAL ARROWS AS
INDICATED
EXIT SIGN, LOW LEVEL
COMBINATION EXIT/EMERGENCY LIGHT FIXTURE
MOUNTING HEIGHT: +8'-0" AFF, UON
EMERGENCY FIXTURE
MOUNTING HEIGHT: +8'-0" AFF, UON
DENOTES FIXTURE CONNECTED TO EMERGENCY CIRCUIT
ADJUSTABLE SPOT OR FLOOD (ARROW INDICATES AIMING)
OUTDOOR SITE LIGHT, POLE MOUNTED LUMINAIRE ARROW
INDICATES AIMING DIRECTION, IF APPLICABLE
BOLLARD OR POST-TOP FIXTURE
LIGHT SWITCH, SPST - MOUNTING HEIGHT: +48" AFF, UON
LIGHT SWITCH, DPST - MOUNTING HEIGHT: +48" AFF, UON
LIGHT SWITCH, 3-WAY - MOUNTING HEIGHT: +48" AFF, UON
MANUAL THERMAL OVERLOAD SWITCH
LOW VOLTAGE SWITCH, MOMENTARY CONTACT, 3-POS.,
CENTER-OFF, MOUNTING HEIGHT: +48" AFF, UON
TIMER SWITCH - MOUNTING HEIGHT: +48" AFF, UON
CIRCUIT AND SWITCH DESIGNATION FOR LIGHTING FIXTURE
CIRCUIT AND RELAY DESIGNATION FOR LIGHTING FIXTURES
(SEE CORRESPONDING LIGHTING CONTROL PANEL RELAY
SCHEDULE)
DIMMER SWITCH - MOUNTING HEIGHT: +48" AFF, UON
OCCUPANCY SENSOR, CEILING MOUNTED, LINE VOLTAGE
OCCUPANCY SENSOR, CEILING MOUNTED, LOW VOLTAGE
OCCUPANCY SENSOR, WALL MOUNTED, LINE VOLTAGE,
1-CIRCUIT - MOUNTING HEIGHT: +48" AFF, UON
OCCUPANCY SENSOR, WALL MOUNTED, LINE VOLTAGE,
2-CIRCUIT - MOUNTING HEIGHT: +48" AFF, UON
PHOTO CONTROL SWITCH - MOUNT ON BUILDING EXTERIOR
TIME CLOCK FOR LIGHTING CONTROL
COMMUNICATIONPOWER
CONDUIT HOME RUN TO DESIGNATED PANEL, TERMINAL, OR
CONTROL CABINET
EXAMPLES:
NOTE FOR CONDUIT: THE MINIMUM CONDUIT SIZE IS 3/4". THE
TIC MARKS INDICATE THE QUANTITY OF #12 AWG WIRES OR, IF
INDICATED, THE QUANTITY OF OTHER SIZE WIRE OR CABLES.
NO TIC MARKS DENOTES TWO #12 AWG WIRES.
SEE THE SINGLE LINE DIAGRAM FOR FEEDER SIZES.
EXAMPLES: = 3/4"C (3) #12 = 3/4"C (2) #10
= 3/4"C (1) TYPE F1 CABLE.
SEE CABLE SCHEDULE.
ELECTRICAL DRAWING INDEX
WH
A
A
F1
T
E5.1
A
E3.1
1. EXAMINE THE DRAWINGS OF OTHER TRADES, BE FAMILIAR WITH THE
DEMOLITION REQUIRED BY OTHER TRADES. PERFORM ALL
INCIDENTAL ELECTRICAL DEMOLITION AND/OR RELOCATION OF
DEVICES AND EQUIPMENT REQUIRED TO FACILITATE THE
DEMOLITION WORK OF OTHER TRADES.
2. REMOVE LIGHTING FIXTURES AND ELECTRICAL DEVICES AS
INDICATED ON PLAN. DEMOLITION SHALL INCLUDE , BUT NOT
LIMITED TO THOSE DEVICES SHOWN.
3. COORDINATE WITH NEW WORK PLANS AND ONE-LINE DIAGRAM FOR
EXTENT OF DEMOLITION WORK.
4. COORDINATE ANY SHUTDOWN OF EXISTING SERVICES AND
EQUIPMENT REMAINING IN USE WITH OWNERS' REPRESENTATIVE.
5. COORDINATE THE SHUTDOWN OF ELECTRICAL EQUIPMENT WITH
THE OWNERS' REPRESENTATIVE A MINIMUM OF 72 HOURS PRIOR TO
THE SHUTDOWN.
6. REMOVE ALL CONDUIT AND WIRE BACK TO NEAREST UPSTREAM
DEVICE REMAINING IN SERVICE.
7. WHERE DEMOLITION WORK AFFECTS ELECTRICAL SERVICE TO
DOWNSTREAM DEVICES TO REMAIN , EXTEND CONDUIT AND WIRE AS
REQUIRED TO MAINTAIN ELECTRICAL SERVICE.
8. ALL MATERIAL SHALL BE DISPOSED OF IN ACCORDANCE WITH
FEDERAL, STATE AND LOCAL REGULATIONS, INCLUDING TCLP
TESTING, PRIOR TO DISPOSAL AND/OR RECYCLING OF
FLUORESCENT LAMPS.
9. PROVIDE BLANK COVER PLATES WHERE SWITCHES AND DEVICES
ARE REMOVED, AND WALL REMAINS INTACT. MARK ALL UNUSED
CIRCUIT BREAKERS AS "SPARE".
10. TAG ALL CIRCUITS AT BOTH ENDS AFFECTED BY THIS ALTERNATION.
11. PROVIDE UPDATED, TYPED-IN DIRECTORIES FOR ALL PANELS
AFFECTED BY THIS ALTERNATION.
12. VERIFY ALL UNDERGROUND AND IN-SLAB UTILITIES LOCATIONS
PRIOR TO SAW CUTTING OR PENETRATING ANY FLOOR SLABS.
13. REFER TO NEW WORK SHEETS FOR LIGHTING AND POWER CIRCUIT
DESIGNATION.
14. EXTEND EXISTING CONDUIT AND WIRE AS REQUIRED FOR ALL
RELOCATED DEVICES.
GENERAL DEMOLITION NOTES
FIRE ALARM
MAGNETIC DOOR HOLD-OPEN DEVICE
FIRE ALARM CONTROL PANEL
= 3/4"C (3) #12 AND
(1) #10 NEUTRAL
= 3/4"C (2) #12
1. EQUIPMENT GROUND SYSTEM SHALL NOT RELY ON METAL CONDUIT
FOR EQUIPMENT GROUND. A GROUND CONDUCTOR (SIZED PER
CODE) SHALL BE INSTALLED IN ALL BRANCH AND FEEDER CONDUITS
U.O.N.
2. ALL WIRING DEVICES SHALL BE WHITE WITH MATCHING DEVICE
PLATES, U.O.N. PROVIDE ENGRAVED CIRCUIT IDENTIFICATIONS ON
PLATES.
3. COORDINATE THE LOCATION OF EACH FAN COIL STARTER AND
DISCONNECT SWITCH WITH MECHANICAL ACCESS PLATES AND
CONDENSATE LINES NEAR EACH FAN COIL, PLUS OTHER
MECHANICAL PIPING OR DUCT WORK AS REQUIRED.
GENERAL NOTES FOR ALL WORK
SHEET
NO. DESCRIPTION
E-001 ELECTRICAL SYMBOLS LEGEND AND ABBREVIATIONS
E-101 PARTIAL SECOND FLOOR ELECTRICAL PLAN - EAST
E-102 PARTIAL SECOND FLOOR ELECTRICAL PLAN - WEST
E-201 ENLARGED MECHANICAL ROOM & ENCLOSURE PLAN
E-301 DETAILS
E-401 SCHEDULES
E-501 SINGLE LINE DIAGRAM
| 081387C-E001.dwg |