DESIGN BASIS
1. THIS PROJECT HAS BEEN DESIGNED IN ACCORDANCE WITH THE UNIFIED
FACILITY CRITERIA WHICH INCLUDES THE ICC 2006 INTERNATIONAL
BUILDING CODE "IBC 2006" AND THE AMERICAN SOCIETY OF CIVIL
ENGINEERS SEI/ASCE 7-05 "MINIMUM DESIGN LOADS FOR BUILDINGS AND
OTHER STRUCTURES"
2. ALL CONSTRUCTION AND INSPECTIONS TO MEET THE REQUIREMENTS OF
ALL UNITED FACILITY CRITERIA (UFC) AND APPROPRIATE REFERENCED
STANDARDS.
3. STRUCTURE DESIGNED FOR WIND LOADS BASED ON THE FOLLOWING
PARAMETERS:
BUILDING CATEGORY = II - “Standard Occupancy”
BASIC WIND SPEED, V = 85 MPH (3 SEC. GUST)
EXPOSURE CATEGORY = C
IMPORTANCE FACTOR, Iw = 1.0
5. STRUCTURE DESIGNED FOR SEISMIC Fp LOADS BASED ON THE FOLLOWING
PARAMETERS:
BUILDING CATEGORY = II - “Standard Occupancy”
SITE CLASS = D (ASSUMED FOR UNKNOWN SOIL)
MAX. 0.2 SEC. SPECTRAL RESPONSE ACCELERATION, Ss = 1.5
MAX. 1.0 SEC. SPECTRAL RESPONSE ACCELERATION, S1 = 0.6
IMPORTANCE FACTOR, Ie = 1.0
SEISMIC DESIGN CATEGORY = D
Fp= 0.5w
6. ATFP CRITERIA
ATFP BUILDING CATEGORY PER UFC 4-010-01; UNOCCUPIED
GENERAL NOTES
1. THE CONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS AND ALL
DIMENSIONS IN FIELD PRIOR TO START OF CONSTRUCTION AND PROTECT
AND MAINTAIN ALL EXISTING CONSTRUCTION AND ITS CONTENTS IN FULL.
2. THE CONTRACTOR SHALL MAINTAIN A SET OF LATEST REVIEWED SHOP
DRAWINGS ON JOB SITE.
3. THE STRUCTURE HAS BEEN DESIGNED TO BE STABLE AND SELF
SUPPORTING AFTER THE CONSTRUCTION IS COMPLETE. IT IS THE
CONTRACTOR'S SOLE RESPONSIBILITY FOR THE BUILDING'S STABILITY
DURING CONSTRUCTION. THIS RESPONSIBILITY ALSO INCLUDES BUT IS
NOT LIMITED TO METHOD AND SEQUENCE OF ERECTION, TEMPORARY
SHORING AND TEMPORARY BRACING.
4. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO FOLLOW ALL
APPLICABLE SAFETY CODES AND REGULATIONS DURING ALL PHASES OF
CONSTRUCTION.
5. ALL SECTIONS, DETAILS, NOTES, DIMENSIONS AND CONDITIONS ARE
APPLICABLE AT ANY OTHER LOCATION WHERE CONDITIONS AND DETAILS
ARE SIMILAR BUT ARE NOT SPECIFICALLY NOTED AS SUCH OR ARE NOT
SHOWN.
FOUNDATION NOTES
1. ALL FOOTINGS TO BEAR ON NATURAL UNDISTURBED SOIL OR COMPACTED
STRUCTURAL HAVING MINIMUM BEARING CAPACITY AS INDICATED.
2. PLACEMENT OF ALL COMPACTED FILL AND COMPACTION OF SUBGRADE
SHALL BE UNDER FULL TIME DIRECTION OF A QUALIFIED GEOTECHNICAL
ENGINEER. CONCRETE FOOTINGS SHALL NOT BE PLACED UNTIL FILL AND
SUBGRADE HAVE BEEN CHECKED IN PLACE AND APPROVED BY THE
GEOTECHNICAL ENGINEER. IF NO FILL, GEOTECHNICAL ENGINEER TO
CONFIRM THAT ASSUMED BEARING CAPACITY IS PRESENT ON SITE.
3. MAXIMUM SLOPE FOR BOTTOM OF FOOTINGS IS TO BE 1 VERTICAL TO 2
HORIZONTAL.
CONCRETE NOTES
1. ALL WORK TO CONFORM TO THE REQUIREMENTS OF THE FOLLOWING
PUBLICATIONS:
A. ACI "BUILDING CODE REQUIREMENTS FOR REINFORCED
CONCRETE" (ACI 318-95), AND "DETAILS AND DETAILING OF
CONCRETE REINFORCEMENT" (ACI 315 - LATEST EDITION).
2. MINIMUM COMPRESSIVE STRENGTH OF CONCRETE AT 28 DAYS:
4000 PSI (NORMAL WEIGHT)
MAXIMUM SLUMP: 5"
PRIOR TO PLACING CONCRETE, MIX DESIGNS SHALL BE SUBMITTED FOR
REVIEW.
3. ALL BAR REINFORCING FOR CONCRETE SHALL CONFORM TO ASTM A 615
GRADE 60 (DEFORMED).
4. UNLESS OTHERWISE SHOWN, LOCATE REINFORCING BARS WITH
FOLLOWING CLEAR DIMENSION TO FACE OF CONCRETE:
A. CONCRETE ON GROUND: 3" CLEAR.
B. EXTERIOR EXPOSED SURFACES OR SURFACES AGAINST
EARTH: 2" CLEAR.
5. CONCRETE ACCESSORIES MUST BE ADEQUATE TO MAINTAIN REINFORCING
ACCURATELY IN PLACE AND BE NON-CORROSIVE, NON-STAINING TYPE
6. LAP ALL BAR REINFORCING IN CONCRETE ELEMENTS 43 BAR DIAMETERS
UNLESS OTHERWISE NOTED.
GENERAL STRUCTURAL NOTES
MASONRY NOTES
1. ALL WORK TO CONFORM TO THE REQUIREMENTS OF THE FOLLOWING
PUBLICATIONS:
A. ACI/ASCE/TMS "BUILDING CODE REQUIREMENTS FOR MASONRY
STRUCTURES" (ACI 530-LATEST EDITION/ASCE 5-LATEST EDITION)
AND "SPECIFICATIONS FOR MASONRY STRUCTURES (ACI
530.1-LATEST EDITION/ASCE 6-LATEST EDITION).
2. MINIMUM NET AREA COMPRESSIVE STRENGTH OF CONCRETE
MASONRY: F'm = 1500 PSI AT 28 DAYS. MINIMUM NET AREA
COMPRESSIVE STRENGTH OF MASONRY UNIT = 1900 PSI
3 .ALL MORTAR FOR CONCRETE MASONRY WALLS SHALL BE TYPE S IN
ACCORDANCE WITH ASTM C270-95.
4. ALL GROUT FOR CONCRETE MASONRY WALLS AND LINTELS SHALL BE
PROPORTIONED AND MIXED IN ACCORDANCE WITH ASTM C476 AND
SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI AT 28
DAYS.
5. ALL CONCRETE MASONRY WALLS SHALL BE REINFORCED AS SHOWN.
SEE TYPICAL DETAILS VERTICAL AND HORIZONTAL BARS AT CORNERS,
CONTROL JOINTS.
6. ALL CELLS OF MASONRY TO BE GROUTED SOLID.
7. GROUTING OF MASONRY UNITS MAY BE DONE BY EITHER THE LOW-LIFT
OR HIGH-LIFT METHODS OF GROUTING:
LOW-LIFT GROUTING - MAXIMUM GROUT POUR HEIGHT SHALL NOT
EXCEED FIVE FEET.
HIGH-LIFT GROUTING - MAXIMUM GROUT POUR HEIGHT SHALL NOT
EXCEED 12 FEET WITHOUT PRIOR APPROVAL; PLACE AND
CONSOLIDATE GROUT IN LIFTS NOT EXCEEDING 5 FEET. IN
ADDITION, CLEANOUT OPENINGS OF SUFFICIENT SIZE SHALL BE
PROVIDED AT THE BOTTOM OF ALL VERTICAL CAVITIES
CONTAINING REINFORCEMENT.
GROUT POURS EXCEEDING 12 INCHES IN HEIGHT ARE TO BE
CONSOLIDATED AND RECONSOLIDATED BY MECHANICAL VIBRATION
PER ACI 530.1/ASCE 6.
8. ALL BAR REINFORCING FOR MASONRY SHALL CONFORM TO ASTM A 615
GRADE 60 (DEFORMED).
9. LAP ALL BAR REINFORCING FOR MASONRY WALLS 48 DIAMETERS
UNLESS OTHERWISE NOTED.
10. ALL VERTICAL REINFORCING BARS IN MASONRY WALLS TO BE PLACED
IN WALLS USING VERTICAL BAR POSITIONERS SPACED AT INTERVALS
NOT EXCEEDING 200 BAR DIAMETERS.
11. ALL MASONRY TO BE LAID IN A RUNNING BOND PATTERN.
12. FABRICATOR TO SUBMIT SHOP DRAWINGS FOR FABRICATION, BENDING,
AND PLACEMENT OF CONCRETE REINFORCEMENT. COMPLY WITH ACI
315 "MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED
CONCRETE STRUCTURES" SHOWING BAR SCHEDULES, STIRRUP
SPACING, TIE SPACING, DIAGRAMS OF BENT BARS, ARRANGEMENT OF
CONCRETE REINFORCEMENT. INCLUDE ADDITIONAL REINFORCEMENT
REQUIRED AT CONTROL JOINTS, CONSTRUCTION JOINTS AND
OPENINGS THROUGH CONCRETE STRUCTURES. SHOW WALL
REINFORCING IN ELEVATIONS. PROVIDE DETAILED LAYOUT DRAWING
FOR DOWELS TO MASONRY WALLS; INCLUDE ADDITIONAL REINFORCING
REQUIRED AT MASONRY OPENINGS, CONTROL JOINTS AND ENDS OF
WALLS.
F O R O F F
IC
IA
L U S E O N L Y
IN
F O R M A T
IO
N S A F E G U A R D
IN
G I S R E Q U
IR
E D
T h e i n fo rm a ti o n c o n ta in e d o n t h is d ra w in g s h a ll re m a in u n d e r th e c o n tr o l o f th e o ri g in a ti n g r e q u e s te r o r a g e n c y o r it s s u c c e s s o r in f u n c ti o n a t a ll ti m e s I n fo rm a ti o n s a fe g u a rd in g i s t h e r e s p o n s ib ili ty o f th e i n d iv id u a l/ a g e n c y /c o m p a n y re q u e s ti n g t h e d a ta a n d t a k in g o ri g in a l p o s s e s s io n o f th is d ra w in g R e le a s e /d is c lo s u re o f d a ta t o a n y p a rt y b e y o n d t h e o ri g in a l re q u e s t a n d i n te n d e d u s e i s p ro h ib it e d N o p u b lic p u b lic a ti o n o f th e d a ta b y a n y m e a n s o r a n a ly s e s t h e re o f is a u th o ri z e d U p o n c o m p le ti o n o f th e u s e o f th e d a ta c o n ta in e d o n t h is d ra w in g th e d ra w in g m u s t b e r e tu rn e d o r d e s tr o y e d D ir e c t a n y q u e s ti o n s t o t h e E n g in e e ri n g S u p p o rt E le m e n t, C
E S
/C E C
B a t -6
-4
In fo rm a ti o n s a fe g u a rd in g r e q u ir e m e n ts a re p e r A
F M
A N
-1
A F I -3
D
O D
R e g
.1 a n d E x e c u ti v e O rd e r w h e n a p p lic a b le
D O N O T D U P L
IC
A T E T H
IS
D R A W
IN
G O R T H E D A T A C O N T A
IN
E D O N I T
| 081387C-S002.dwg |
| Structural |
File details come from the government source that posted it. Updated .