The specification establishes requirements for elastomeric joint sealants, primers, bond breakers, backstops, and related materials for interior and exterior applications. Interior sealants must comply with ASTM C920, Type S or M, Grade NS, Class 12.5, Use NT, with color selection from manufacturer's full range. Exterior sealants for vertical surfaces require ASTM C920, Type S or M, Grade NS, Class 25, Use NT; for horizontal surfaces, Type S or M, Grade P, Class 25, Use T. Floor joint sealants must meet ASTM C920, Type S or M, Grade P, Class 25, Use T. Acoustical sealants must comply with ASTM C919 with flame spread of 25 or less and smoke developed rating of 50 or less per ASTM E84, with consistency of 250 to 310 per ASTM D217. Preformed sealants include polybutylene or isoprene-butylene pressure-sensitive tape, bead sealants, and polyurethane foam strips with specified temperature ranges. All products require third-party certification for low volatile organic compounds (VOC) content per UL 2818 Gold, SCS Indoor Advantage Gold, or approved equivalent. Contractors must submit product data, test reports on field adhesion, and certifications for government approval (designated "G" submissions). Application requirements specify joint width-to-depth ratios, surface preparation protocols for steel, aluminum, bronze, concrete, masonry, and wood surfaces, backstop installation, primer application for porous surfaces, and masking tape procedures. Field adhesion testing per ASTM C1193 or ASTM C1521 is required, with failed sealants to be removed and reapplied. Environmental conditions restrict application to ambient temperatures between 40 and 90 degrees Fahrenheit.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Ti nker AFB, OK TAFB Techni cal Spr ci f i cat i ons 2019
SECTI ON 07 92 00
JOI NT SEALANTS
PART 1 GENERAL
1. 1 REFERENCES
The publ i cat i ons l i s t ed bel ow f or m a par t of t hi s speci f i cat i on t o t he ext ent r ef er enced. The publ i cat i ons ar e r ef er r ed t o wi t hi n t he t ext by t he basi c desi gnat i on onl y.
ASTM I NTERNATI ONAL ( ASTM)
ASTM C1193 ( 2013) St andar d Gui de f or Use of Joi nt Sealants
ASTM C1311 ( 2014) St andar d Speci f i cat i on f or Sol vent Rel ease Agent s
ASTM C1521 ( 2013) St andar d Pr act i ce f or Eval uat i ng Adhesi on of I nst al l ed Weat her pr oof i ng Seal ant Joi nt s
ASTM C509 ( 2006; R 2015) El ast omer i c Cel l ul ar Pr ef or med Gasket and Seal i ng Mat er i al
ASTM C734 ( 2015) Low- Temper at ur e Fl exi bi l i t y of Lat ex Seal ant s Af t er Ar t i f i c i al Weat her i ng
ASTM C919 ( 2012) Use of Seal ant s i n Acoust i cal Applications
ASTM C920 ( 2014a) St andar d Speci f i cat i on f or El ast omer i c Joi nt Seal ant s
ASTM D1056 ( 2014) St andar d Speci f i cat i on f or Fl exi bl e Cel l ul ar Mat er i al s - Sponge or Expanded Rubber
ASTM D217 ( 2010) Cone Penet r at i on of Lubr i cat i ng Grease
ASTM D2452 ( 2015) St andar d Test Met hod f or Ext r udabi l i t y of Oi l - and Resi n- Base Caul ki ng Compounds
ASTM D2453 ( 2015) St andar d Test Met hod f or Shr i nkage and Tenaci t y of Oi l - and Resi n- Base Caul ki ng Compounds
ASTM E84 ( 2015b) St andar d Test Met hod f or Sur f ace Bur ni ng Char act er i st i cs of Bui l di ng Materials
Apr i l 2019 Page 1 SECTI ON 07 92 00
SCI ENTI FI C CERTI FI CATI ON SYSTEMS ( SCS)
SCS Sci ent i f i c Cer t i f i cat i on Syst ems ( SCS) I ndoor Advant age
UNDERWRI TERS LABORATORI ES ( UL)
UL 2818 ( 2013) GREENGUARD Cer t i f i cat i on Pr ogr am For Chemi cal Emi ssi ons For Bui l di ng Mat er i al s, Fi ni shes And Fur ni shi ngs
1. 2 SUBMITTALS
Gover nment appr oval i s r equi r ed f or submi t t al s wi t h a " G" desi gnat i on;
submi t t al s not havi ng a " G" desi gnat i on ar e f or Cont r act or Qual i t y Cont r ol appr oval . Submi t t he f ol l owi ng i n accor dance wi t h Sect i on 01 33 00
SUBMI TTAL PROCEDURES:
SD- 03 Pr oduct Dat a
Seal ant s; G
Pr i mer s; G
Bond Br eaker s; G
Backst ops; G
SD- 06 Test Repor t s
Fi el d Adhesi on; G
SD- 07 Cer t i f i cat es
Seal ant ; G
Pr i mer s; G
Bond Br eaker s; G
Vol at i l e Or gani c Compounds ( VOC) Cont ent ; G
SD- 11 Cl oseout Submi t t al s
Vol at i l e Or gani c Compounds ( VOC) Cont ent ; S
1. 3 PRODUCT DATA
I ncl ude st or age r equi r ement s, shel f l i f e, cur i ng t i me, i nst r uct i ons f or mi xi ng and appl i cat i on, and accessor i es. Pr ovi de manuf act ur er ' s Mat er i al Saf et y Dat a Sheet ( MSDS) f or each sol vent , pr i mer and seal ant mat er i al proposed.
1. 4 CERTIFICATIONS
Pr ovi de pr oduct t hi r d- par t y cer t i f i cat i on f or l ow Vol at i l e Or gani c Compounds ( VOC) Cont ent i n accor dance wi t h UL 2818 Gol d, SCS ( Sci ent i f i c Cer t i f i cat i on Syst ems) I ndoor Advant age Gol d or appr oved equal .
Apr i l 2019 Page 2 SECTI ON 07 92 00
1. 5 ENVI RONMENTAL CONDI TI ONS
Appl y seal ant when t he ambi ent t emper at ur e i s bet ween 40 and 90 degr ees F.
1. 6 DELI VERY AND STORAGE
Del i ver mat er i al s t o t he j obsi t e i n unopened manuf act ur er s ' seal ed shi ppi ng cont ai ner s, wi t h br and name, dat e of manuf act ur e, col or , and mat er i al desi gnat i on c l ear l y mar ked t her eon. Label el ast omer i c seal ant cont ai ner s t o i dent i f y t ype, c l ass, gr ade, and use. Handl e and st or e mat er i al s i n accor dance wi t h manuf act ur er ' s pr i nt ed i nst r uct i ons. Pr event exposur e t o f or ei gn mat er i al s or subj ect i on t o sust ai ned t emper at ur es exceedi ng 90 degr ees F or l ower t han 0 degr ees F. Keep mat er i al s and cont ai ner s c l osed and separ at ed f r om absor pt i ve mat er i al s such as wood and insulation.
1. 7 QUALI TY ASSURANCE
1. 7. 1 Compat i bi l i t y wi t h Subst r at e
Ver i f y t hat each seal ant i s compat i bl e f or use wi t h each j oi nt subst r at e i n accor dance wi t h seal ant manuf act ur er ' s pr i nt ed r ecommendat i ons f or each application.
1. 7. 2 Joi nt Tol er ance
Pr ovi de j oi nt t ol er ances i n accor dance wi t h manuf act ur er ' s pr i nt ed instructions.
1. 7. 3 Mock-Up
Pr ovi de a mock- up of each t ype of seal ant usi ng mat er i al s, col or s, and t echni ques appr oved f or use on t he pr oj ect . Appr oved mock- ups may be i ncor por at ed i nt o t he Wor k.
1. 7. 4 Adhesion
Pr ovi de i n accor dance wi t h ASTM C1193 or ASTM C1521.
PART 2 PRODUCTS
2. 1 SEALANTS
Pr ovi de seal ant pr oduct s t hat have been t est ed, f ound sui t abl e, and document ed as such by t he manuf act ur er f or t he par t i cul ar subst r at es t o whi ch t hey wi l l be appl i ed.
2. 1. 1 Pr oduct Sust ai nabi l i t y Cr i t er i a
Wher e al l owed by per f or mance cr i t er i a, pr ovi de seal ant s speci f i ed f or i nt er i or use wi t h r educed Vol at i l e Or gani c Compounds ( VOC) cont ent .
Pr ovi de document at i on i n accor dance wi t h Sect i on 01 33 29 SUSTAI NABI LI TY REPORTI NG par agr aph REDUCE VOLATI LE ORGANI C COMPOUNDS.
2. 1. 2 I nt er i or Seal ant s
Provide ASTM C920, Type S or M, Gr ade NS, Cl ass 12. 5, Use NT. Locat i on( s) and col or ( s) of seal ant f or t he f ol l owi ng. Not e, col or " as sel ect ed" r ef er s t o manuf act ur er ' s f ul l r ange of col or opt i ons
Apr i l 2019 Page 3 SECTI ON 07 92 00
LOCATION COLOR
a. Smal l voi ds bet ween wal l s or par t i t i ons and adj acent l ocker s, casewor k, shel vi ng, door f r ames, bui l t - i n or sur f ace mount ed equi pment and f i xt ur es, and si mi l ar i t ems.
As sel ect ed
b. Per i met er of f r ames at door s, wi ndows, and access panel s whi ch adj oi n exposed i nt er i or concr et e and masonr y sur f aces.
As sel ect ed
c. Joi nt s of i nt er i or masonr y wal l s and par t i t i ons whi ch adj oi n col umns, pi l ast er s, concr et e wal l s, and ext er i or wal l s unl ess ot her wi se det ai l ed.
As sel ect ed
d. Joi nt s bet ween edge member s f or acoust i cal t i l e and adj oi ni ng ver t i cal sur f aces.
As sel ect ed
e. I nt er i or l ocat i ons, not ot her wi se i ndi cat ed or speci f i ed, wher e smal l voi ds exi st bet ween mat er i al s speci f i ed t o be pai nt ed.
As sel ect ed f . Joi nt s bet ween bat ht ubs and cer ami c t i l e; j oi nt s bet ween shower r ecept or s and cer ami c t i l e; j oi nt s f or med wher e non- pl anar t i l e sur f aces meet .
As sel ect ed
g. Joi nt s f or med bet ween t i l e f l oor s and t i l e base cove; j oi nt s bet ween t i l e and di ssi mi l ar mat er i al s; j oi nt s occur r i ng wher e subst r at es change.
As sel ect ed
h. Behi nd escut cheon pl at es at val ve pi pe penet r at i ons and shower heads i n shower s.
As sel ect ed
2. 1. 3 Ext er i or Seal ant s
For j oi nt s i n ver t i cal sur f aces, pr ovi de ASTM C920, Type S or M, Gr ade NS, Cl ass 25, Use NT. For j oi nt s i n hor i zont al sur f aces, pr ovi de ASTM C920, Type S or M, Gr ade P, Cl ass 25, Use T. Pr ovi de l ocat i on( s) and col or ( s) of seal ant as f ol l ows. Not e, col or " as sel ect ed" r ef er s t o manuf act ur er ' s f ul l r ange of col or opt i ons:
LOCATION COLOR
a. Joi nt s and r ecesses f or med wher e f r ames and subsi l l s of wi ndows, door s, l ouver s, and vent s adj oi n masonr y, concr et e, or met al f r ames. Use seal ant at bot h ext er i or and i nt er i or sur f aces of ext er i or wal l penetrations.
Mat ch adj acent sur f ace col or
Apr i l 2019 Page 4 SECTI ON 07 92 00
LOCATION COLOR
b. Joi nt s bet ween new and exi st i ng ext er i or masonr y wal l s.
Mat ch adj acent sur f ace col or
c. Masonr y j oi nt s wher e shel f angl es occur . Mat ch mor t ar col or
d. Joi nt s i n wash sur f aces of st onewor k. Mat ch mor t ar col or
e. Expansi on and cont r ol j oi nt s. As sel ect ed f . I nt er i or f ace of expansi on j oi nt s i n ext er i or concr et e or masonr y wal l s wher e met al expansi on j oi nt cover s ar e not required.
As sel ect ed
g. Voi ds wher e i t ems pass t hr ough ext er i or walls.
Mat ch adj acent sur f ace col or
h. Met al r egl et s, wher e f l ashi ng i s i nser t ed i nt o masonr y j oi nt s, and wher e f l ashi ng i s penet r at ed by copi ng dowel s.
Gray i . Met al - t o- met al j oi nt s wher e seal ant i s i ndi cat ed or speci f i ed.
As sel ect ed j . Joi nt s bet ween ends of gr avel st ops, f asci ae, copi ngs, and adj acent wal l s.
As sel ect ed
2. 1. 4 Fl oor Joi nt Seal ant s
ASTM C920, Type S or M, Gr ade P, Cl ass 25, Use T. Pr ovi de l ocat i on( s) and col or ( s) of seal ant as f ol l ows. Not e, col or " as sel ect ed" r ef er s t o manuf act ur er ' s f ul l r ange of col or opt i ons:
LOCATION COLOR
a. Seat s of met al t hr eshol ds f or ext er i or doors.
Gray____
b. Cont r ol and expansi on j oi nt s i n f l oor s, s l abs, cer ami c t i l e, and wal kways.
As sel ect ed
2. 1. 5 Acoust i cal Seal ant s
Rubber or pol ymer based acoust i cal seal ant i n accor dance wi t h ASTM C919 t o have a f l ame spr ead of 25 or l ess and a smoke devel oped r at i ng of 50 or l ess when t est ed i n accor dance wi t h ASTM E84. Pr ovi de non- st ai ni ng
Apr i l 2019 Page 5 SECTI ON 07 92 00 acoust i cal seal ant wi t h a consi st ency of 250 t o 310 when t est ed i n accor dance wi t h ASTM D217. Acoust i cal seal ant must r emai n f l exi bl e and adhesi ve af t er 500 hour s of accel er at ed weat her i ng as speci f i ed i n
ASTM C734.
2. 1. 6 Pr ef or med Seal ant s
Pr ovi de pr ef or med seal ant s of pol ybut yl ene or i sopr ene- but yl ene based pr essur e sensi t i ve weat her r esi st ant t ape or bead seal ant s capabl e of seal i ng out moi st ur e, ai r and dust when i nst al l ed as r ecommended by t he manuf act ur er . At t emper at ur es f r om mi nus30 t o pl us 160 degr ees F, seal ant s must be non- bl eedi ng and have no l oss of adhesi on.
2. 1. 6. 1 Tape
Tape seal ant : Pr ovi de cr oss sect i on di mensi ons as shown i n dr awi ngs.
2. 1. 6. 2 Bead
Bead seal ant : Pr ovi de cr oss sect i on di mensi ons as shown i n dr awi ngs.
2. 1. 6. 3 Foam St r i p
Pr ovi de f oam st r i p of pol yur et hane f oam . Pr ovi de f oam st r i p capabl e of seal i ng out moi st ur e, ai r , and dust when i nst al l ed and compr essed i n accor dance wi t h manuf act ur er ' s pr i nt ed i nst r uct i ons. Ser vi ce t emper at ur e must bemi nus 40 t o pl us 275 degr ees F. Fur ni sh unt r eat ed st r i ps wi t h adhesi ve t o hol d t hem i n pl ace. Do not al l ow adhesi ve t o st ai n or bl eed ont o adj acent f i ni shes. Sat ur at e t r eat ed st r i ps wi t h but yl ene wat er pr oof i ng or i mpr egnat e wi t h asphal t .
2. 2 PRIMERS
Non- st ai ni ng, qui ck dr yi ng t ype and consi st ency as r ecommended by t he seal ant manuf act ur er f or t he par t i cul ar appl i cat i on.
2. 3 BOND BREAKERS
Type and consi st ency as r ecommended by t he seal ant manuf act ur er t o pr event adhesi on of t he seal ant t o t he backi ng or t o t he bot t om of t he j oi nt .
2. 4 BACKSTOPS
Pr ovi de gl ass f i ber r ovi ng, neopr ene, but yl , pol yur et hane, or pol yet hyl ene f oams f r ee f r om oi l or ot her st ai ni ng el ement s as r ecommended by seal ant manuf act ur er . Pr ovi de 25 t o 33 per cent over si zed backi ng f or c l osed cel l and 40 t o 50 per cent over si zed backi ng f or open cel l mat er i al , unl ess ot her wi se i ndi cat ed. Pr ovi de backst op mat er i al t hat i s compat i bl e wi t h seal ant . Do not use oakum or ot her t ypes of absor pt i ve mat er i al s as backstops.
2. 4. 1 Rubber
Pr ovi de i n accor dance wi t h ASTM D1056, Type 2, c l osed cel l , Cl ass B, Gr ade __2___, r ound cr oss sect i on f or cel l ul ar r ubber sponge backi ng.
2. 4. 2 Synt het i c Rubber
Pr ovi de i n accor dance wi t h ASTM C509, Opt i on I , Type I I pr ef or med r ods
Apr i l 2019 Page 6 SECTI ON 07 92 00 synt het i c r ubber backi ng.
2. 4. 3 Neoprene
Pr ovi de i n accor dance wi t h ASTM D1056, c l osed cel l expanded neopr ene cor d Type 2, Cl ass C, Gr ade 2C2 neopr ene backi ng.
2. 4. 4 But yl Rubber Based
Pr ovi de i n accor dance wi t h ASTM C1311, f r om a si ngl e component , wi t h sol vent r el ease. col or as sel ect ed f r om manuf act ur er ' s f ul l r ange of col or choices.
2. 4. 5 Si l i cone Rubber Base
Pr ovi de i n accor dance wi t h ASTM C920, f r om a si ngl e component , wi t h sol vent r el ease, Non- sag, Type ___S or M__, Gr ade __NS___, Cl ass 25 _NT__.
Col or as sel ect ed f r om manuf act ur er ' s f ul l r ange of col or choi ces .
2. 5 CAULKING
For i nt er i or use and onl y wher e t her e i s l i t t l e or no ant i c i pat ed j oi nt movement . Pr ovi de i n accor dance wi t h ASTM D2452 and ASTM D2453, Type __I ___, f or oi l and r esi n- based caul k i ng.
2. 6 CLEANI NG SOLVENTS
Pr ovi de t ype( s) r ecommended by t he seal ant manuf act ur er and i n accor dance wi t h envi r onment al r equi r ement s her ei n. Pr ot ect adj acent al umi num and br onze sur f aces f r om sol vent s.
PART 3 EXECUTI ON
3. 1 FI ELD QUALI TY CONTROL
Per f or m a f i el d adhesi on t est i n accor dance wi t h manuf act ur er ' s i nst r uct i ons and ASTM C1193, Met hod A or ASTM C1521, Met hod A, Tai l Pr ocedur e. Remove seal ant s t hat f ai l adhesi on t est i ng; c l ean subst r at es, r eappl y seal ant s, and r e- t est . Test seal ant s adj acent t o f ai l ed seal ant s.
Submi t f i el d adhesi on t est r epor t i ndi cat i ng t est s, l ocat i ons, dat es, r esul t s, and r emedi al act i ons t aken.
3. 2 SURFACE PREPARATI ON
Pr epar e sur f aces accor di ng t o manuf act ur er ' s pr i nt ed i nst al l at i on i nst r uct i ons. Cl ean sur f aces f r om di r t , f r ost , moi st ur e, gr ease, oi l , wax, l acquer , pai nt , or ot her f or ei gn mat t er t hat woul d dest r oy or i mpai r adhesi on. Remove oi l and gr ease wi t h sol vent ; t hor oughl y r emove sol vent s pr i or t o seal ant i nst al l at i on. Wi pe sur f aces dr y wi t h c l ean cl ot hs. When r eseal i ng an exi st i ng j oi nt , r emove exi st i ng caul k or seal ant pr i or t o appl y i ng new seal ant . For sur f ace t ypes not l i s t ed bel ow, pr ovi de i n accor dance wi t h seal ant manuf act ur er ' s pr i nt ed i nst r uct i ons f or each speci f i c sur f ace.
3. 2. 1 St eel Sur f aces
Remove l oose mi l l scal e by sandbl ast i ng or , i f sandbl ast i ng i s i mpr act i cal or woul d damage f i ni shed wor k, scr api ng and wi r e br ushi ng. Remove pr ot ect i ve coat i ngs by sandbl ast i ng or usi ng a r esi due f r ee sol vent .
Apr i l 2019 Page 7 SECTI ON 07 92 00
Remove r esul t i ng debr i s and sol vent r esi due pr i or t o seal ant i nst al l at i on.
3. 2. 2 Al umi num or Br onze Sur f aces
Remove t empor ar y pr ot ect i ve coat i ngs f r om sur f aces t hat wi l l be i n cont act wi t h seal ant . When maski ng t ape i s used as a pr ot ect i ve coat i ng, r emove t ape and any r esi dual adhesi ve pr i or t o seal ant appl i cat i on. For r emovi ng pr ot ect i ve coat i ngs and f i nal c l eani ng, use non- st ai ni ng sol vent s r ecommended by t he manuf act ur er of t he i t em( s) cont ai ni ng al umi num or br onze sur f aces.
3. 2. 3 Concr et e and Masonr y Sur f aces
Wher e sur f aces have been t r eat ed wi t h cur i ng compounds, oi l , or ot her such mat er i al s, r emove mat er i al s by sandbl ast i ng or wi r e br ushi ng. Remove l ai t ance, ef f l or escence and l oose mor t ar f r om t he j oi nt cavi t y. Remove r esul t i ng debr i s pr i or t o seal ant i nst al l at i on.
3. 2. 4 Wood Sur f aces
Ensur e wood sur f aces t hat wi l l be i n cont act wi t h seal ant s ar e f r ee of spl i nt er s, sawdust and ot her l oose par t i c l es.
3. 3 SEALANT PREPARATI ON
Do not add l i qui ds, sol vent s, or powder s t o seal ant s. Mi x mul t i component el ast omer i c seal ant s i n accor dance wi t h manuf act ur er ' s pr i nt ed instructions.
3. 4 APPLICATION
3. 4. 1 Joi nt Wi dt h- To- Dept h Rat i os
Accept abl e Rat i os:
JOI NT WI DTH JOI NT DEPTH
Minimum Maximum
For met al , gl ass, or ot her nonpor ous sur f aces:
1/ 4 i nch ( mi ni mum) 1/ 4 i nch 1/ 4 i nch over 1/ 4 i nch 1/ 2 of wi dt h Equal t o wi dt h
For wood, concr et e, masonr y, st one:
1/ 4 i nch ( mi ni mum) 1/ 4 i nch 1/ 4 i nch over 1/ 4 i nch t o 1/ 2 i nch 1/ 4 i nch Equal t o wi dt h over 1/ 2 i nch t o 1 i nch 1/ 2 i nch 5/ 8 i nch
Over 1 i nch prohibited
Unaccept abl e Rat i os: Wher e j oi nt s of accept abl e wi dt h- t o- dept h r at i os have not been pr ovi ded, c l ean out j oi nt s t o accept abl e dept hs and gr i nd or
Apr i l 2019 Page 8 SECTI ON 07 92 00 cut t o accept abl e wi dt hs wi t hout damage t o t he adj oi ni ng wor k. Gr i ndi ng i s pr ohi bi t ed at met al sur f aces.
3. 4. 2 Unaccept abl e Seal ant Use
Do not i nst al l seal ant s i n l i eu of ot her r equi r ed bui l di ng encl osur e weat her pr oof i ng component s such as f l ashi ng, dr ai nage component s, and j oi nt c l osur e accessor i es, or t o c l ose gaps bet ween wal l s, f l oor s, r oof s, wi ndows, and door s, t hat exceed accept abl e i nst al l at i on t ol er ances.
Remove seal ant s t hat have been used i n an unaccept abl e manner and cor r ect bui l di ng encl osur e def i c i enci es t o compl y wi t h cont r act document s requirements.
3. 4. 3 Maski ng Tape
Pl ace maski ng t ape on t he f i ni shed sur f ace on one or bot h s i des of j oi nt cavi t i es t o pr ot ect adj acent f i ni shed sur f aces f r om pr i mer or seal ant smear s. Remove maski ng t ape wi t hi n 10 mi nut es of j oi nt f i l l i ng and tooling.
3. 4. 4 Backstops
Pr ovi de backst ops dr y and f r ee of t ear s or hol es. Ti ght l y pack t he back or bot t om of j oi nt cavi t i es wi t h backst op mat er i al t o pr ovi de j oi nt s i n speci f i ed dept hs. Pr ovi de backst ops wher e i ndi cat ed and wher e backst ops ar e not i ndi cat ed but j oi nt cavi t i es exceed t he accept abl e maxi mum dept hs speci f i ed i n " Joi nt Wi dt h- t o- Dept h Rat i os" Tabl e.
3. 4. 5 Primer
Cl ean out l oose par t i c l es f r om j oi nt s i mmedi at el y pr i or t o appl i cat i on of . Appl y pr i mer t o j oi nt s i n concr et e masonr y uni t s, wood, and ot her por ous sur f aces i n accor dance wi t h seal ant manuf act ur er ' s pr i nt ed i nst r uct i ons. Do not appl y pr i mer t o exposed f i ni shed sur f aces.
3. 4. 6 Bond Br eaker
Pr ovi de bond br eaker s t o sur f aces not i nt ended t o bond i n accor dance wi t h, seal ant manuf act ur er ' s pr i nt ed i nst r uct i ons f or each t ype of sur f ace and seal ant combi nat i on speci f i ed.
3. 4. 7 Sealants
Pr ovi de seal ant s compat i bl e wi t h t he mat er i al ( s) t o whi ch t hey ar e appl i ed. Do not use a seal ant t hat has exceeded i t s shel f l i f e or has j el l ed and cannot be di schar ged i n a cont i nuous f l ow f r om t he seal ant gun. Appl y seal ant s i n accor dance wi t h t he manuf act ur er ' s pr i nt ed i nst r uct i ons wi t h a gun havi ng a nozzl e t hat f i t s t he j oi nt wi dt h. Wor k seal ant i nt o j oi nt s so as t o f i l l t he j oi nt s sol i dl y wi t hout ai r pocket s.
Tool seal ant af t er appl i cat i on t o ensur e adhesi on. Appl y seal ant uni f or ml y smoot h and f r ee of wr i nkl es. Upon compl et i on of seal ant appl i cat i on, r oughen par t i al l y f i l l ed or unf i l l ed j oi nt s, appl y addi t i onal seal ant , and t ool smoot h as speci f i ed. Appl y seal er over seal ant s i n accor dance wi t h t he seal ant manuf act ur er ' s pr i nt ed i nst r uct i ons.
Apr i l 2019 Page 9 SECTI ON 07 92 00
3. 5 PROTECTI ON AND CLEANI NG
3. 5. 1 Protection
Pr ot ect ar eas adj acent t o j oi nt s f r om seal ant smear s. Maski ng t ape may be used f or t hi s pur pose i f r emoved 5 t o 10 mi nut es af t er t he j oi nt i s f i l l ed and no r esi dual t ape mar ks r emai n.
3. 5. 2 Fi nal Cl eani ng
Upon compl et i on of seal ant appl i cat i on, r emove r emai ni ng smear s and st ai ns and l eave t he wor k i n a c l ean and neat condi t i on.
a. Masonr y and Ot her Por ous Sur f aces: I mmedi at el y r emove f r esh seal ant t hat has been smear ed on adj acent masonr y, r ub c l ean wi t h a sol vent , and r emove sol vent r esi due, i n accor dance wi t h seal ant manuf act ur er ' s pr i nt ed i nst r uct i ons. Al l ow excess seal ant t o cur e f or 24 hour t hen r emove by wi r e br ushi ng or sandi ng. Remove r esul t i ng debr i s.
b. Met al and Ot her Non- Por ous Sur f aces: Remove excess seal ant wi t h a sol vent moi st ened cl ot h. Remove sol vent r esi due i n accor dance wi t h sol vent manuf act ur er ' s pr i nt ed i nst r uct i ons.
- - End of Sect i on - -