VTD Upgrades

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
6973GH-24-R-00121
Agency
Franchise Acquisition Servies Federal Aviation Administration, Department of Transportation
Responses due
Set-aside
Total Small Business

Opportunity facts

NAICS code
236220 Commercial and Institutional Building Construction
PSC
Z1AZ Maintenance Of Other Administrative Facilities And Service Buildings
Place of performance
Oklahoma City, Oklahoma 73169, United States
Points of contact

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Transportation Federal Aviation Administration Franchise Acquisition Services is issuing Solicitation Number 6973GH-24-R-00121 to upgrade the heating, ventilating, and air-conditioning (HVAC) systems at the VTD facility located at the Mike Monroney Aeronautical Center in Oklahoma City, OK. The work includes replacing two 100-ton air-cooled chillers, primary and secondary chilled water pumps, variable air volume air handling units, computer room air-conditioning units, and updating the existing energy management control system. The contractor shall also provide site drainage rework, new natural gas piping, and replace the existing diesel engine generator with a natural gas generator. Proposals are due by 5:00 p.m. Central Time on June 28, 2024 and must be submitted to the Contracting Officer, Elizabeth Fikes, via email. The solicitation includes Sections L and M providing instructions to bidders and the evaluation factors for award.

This is a total small business set-aside opportunity. The estimated value is not provided. The contract performance period is 640 calendar days, with two whole building shutdowns anticipated. The work must be closely coordinated with the Contracting Officer's Representative to minimize disruptions to the facility's 12-hour per day, 5-day per week operations.

Notice text

11 versions

Update #11 · Latest ·

AMENDMENT 0006:

FIRST: The purpose of Amendment 0006 is to attach pdf file “Prior Approval_FAA VTD Upgrades“ in response to Question #3, clarify Question #6 on Attachment 15. Questions and Answers _7.12.24_6973GH-24-R-00121_VTD, and extend the proposal due date to Monday, July 22, 2024.

3. Request for equipment substitution request for VTD building upgrades. See Attachment 19 pdf titled:

Prior Approval_FAA VTD Upgrades.

Government Response: Expansion Tank, Glycol Feeder and CHW Buffer Tank are approved. Aerco Boiler is not approved. Provide boiler scheduled. Add the ModSync boiler control panel.

SECOND: Past Performance Surveys submitted prior to 7/15/2024 must be corrected and resubmitted regarding Question #6 of Attachment 15. Questions and Answers _7.12.24_6973GH-24-R-00121_VTD.

THIRD: Proposal due date is extended to Monday, July 22, 2024.

END OF AMENDMENT 0006

AMENDMENT 0005:

The purpose of Amendment 0005 is as follows:

  1. Questions and Answers/Substitution Requests dated July 12, 2024, is incorporated as Attachment 15, Questions and Answers_7.12.24_6973GH-24-R-00121_VTD

        2. The following pdf attachments are incorporated in amendment 0005.

Attachment 16 - FAA VTD Upgrades-Roofing SubReq_SA-APP

Attachment 17 - Submittal24-33387-0-581343-SA_APP_LDG

Attachment 18 - MMAC VTP Storefront Substitution Request  [17677]-SA_AAN

       3. Attachment 10 – Past Performance Survey is corrected and incorporated in this amendment.

END OF AMENDMENT 0005

***************************************************************************************************************************************************

AMENDMENT 0004:

Proposal due date is extended to Friday, July 17, 2024 at 1700 CDT to allow submitted questions to be answered.

END OF AMENDMENT 0004

***************************************************************************************************************************************************

AMENDMENT 0003:

Proposal due date is extended to Friday, July 5, 2024 at 1700 CDT to allow submitted questions to be answered.

END OF AMENDMENT 0003

***************************************************************************************************************************************************

UPDATE:

June 18, 2024 Site Visit sign-in sheet added to attachments.

END OF UPDATE

***************************************************************************************************************************************************

June 12, 2024 AMENDMENT 0002

The purpose of Amendment 0002 is to establish an additional site visit to include roof access, add the June 6, 2024 site visit sign-in sheet, and extend the date when questions are due as follows:

1. Additional Site Visit will be held on Tuesday, June 18, 2024 at 11:30 a.m. CDT. Participants will meet at the MMAC Visitor Center between 11:15-11:30 a.m. CDT.

2. Questions must be submitted to elizabeth.a.fikes@faa.gov no later than Friday, June 21, 2024 at 5:00 p.m. CDT.

END OF AMENDMENT 0002

***************************************************************************************************************************************************

June 6, 2024 AMENDMENT 0001

The purpose of Amendment 0001 is to correct the contract number listed on Attachment 10-Past Performance Survey in Section J.

END OF AMENDMENT 0001

******************************************************************************************************************************************************

June 5, 2024 UPDATE:

Site Visit meeting will start at the MMAC Visitors Center. Meet at 0915 then we will drive to the site. There is only 1 (one) visitor center. 

END OF UPDATE

***************************************************************************************************************************************************

June 4, 2024 UPDATE:

Email address in Section L paragraph L.1(f) is corrected as follows:

TO:

(f) FAA personnel who will be evaluating proposals received in response to this SIR are working remotely; therefore, offerors should keep this in mind when preparing and submitting proposals. Documentation shall be submitted electronically in accordance with Section L, Clause 3.2.2.3-20, Electronic Offers. Note: Proposal Sections I and II shall be submitted as separate documents. NOTE: Due to FAA email size limitations, it is highly recommended that offerors submit their email proposal for each volume as separate emails and in the email subject line state 6973GH-4-R-00121, Section “**” Submitted on Behalf of “**”. PROPOSALS MUST BE EMAIL TO Elizabeth.a.fikes@faa.gov.

FROM:

(f) FAA personnel who will be evaluating proposals received in response to this SIR are working remotely; therefore, offerors should keep this in mind when preparing and submitting proposals. Documentation shall be submitted electronically in accordance with Section L, Clause 3.2.2.3-20, Electronic Offers. Note: Proposal Sections I and II shall be submitted as separate documents. NOTE: Due to FAA email size limitations, it is highly recommended that offerors submit their email proposal for each volume as separate emails and in the email subject line state 6973GH-4-R-00121, Section “**” Submitted on Behalf of “**”. PROPOSALS MUST BE EMAIL TO Elizabeth.a.fikes@us.af.mil.

END OF UPDATE

************************************************************************************************************************************************

May 31, 2024 UPDATE:

Section L paragraph L.1(b) has changed as follows:

TO:

(b) Offerors are allowed to send a maximum of THREE individuals to represent their proposal (to include proposal teams, if applicable). Please advise the Contract Specialist (Elizabeth Fikes, Elizabeth.a.fikes@faa.gov) in writing of your intent to attend by 5:00 p.m. Central Time, Monday, June 3, 2024. Telephone requests will NOT count as notification of attendance. The Contracting Officer will send out information no later than 11:00 a.m., Wednesday, June 5, 2024, to ONLY those that have provided the required response information. Your request should include the following information:

FROM:

(b) Offerors are allowed to send a maximum of ONE individual to represent their proposal (to include proposal teams, if applicable). Please advise the Contract Specialist (Elizabeth Fikes, Elizabeth.a.fikes@faa.gov) in writing of your intent to attend by 5:00 p.m. Central Time, Monday, June 3, 2024. Telephone requests will NOT count as notification of attendance. The Contracting Officer will send out information no later than 11:00 a.m., Wednesday, June 5, 2024, to ONLY those that have provided the required response information. Your request should include the following information:

END OF UPDATE

************************************************************************************************************************************************

This is a solicitation to assist the FAA in meeting the VTD Upgrade requirement at the Mike Monroney Aeronautical Center in Oklahoma City, OK and includes:

1. Description of Facility:

1.1 Building Area: 24,531 SF

1.2 Building Age: 11-1-1996

1.3 Building Function: Training, classrooms, administration spaces, etc.

1.4 The construction site address is: VTD B204, 7600 Quesada Drive, Oklahoma City, OK 73169.

2. Description of Work:

2.1 Upgrade heating, ventilating, and air-conditioning (HVAC) systems in the VTD facility.

Two (2EA) 100 Ton air-cooled chillers located in the outside the mechanical yard are being updated under separate contract.

2.2 Two (2EA) constant volume primary chilled water pumps (PCHW), two (2EA) variable flow secondary CHW pumps (SCHWPs), two (2EA) variable air volume air handling units (VAV AHUs), two (2EA) computer room air-conditioning units (CRACs), etc. Existing JCI Metasys campus-wide energy management control system (EMCS) will be updated.

2.3 Site drainage is being re-worked and a new natural gas piping to be installed. Replace existing diesel engine generator with a natural-gas engine generator. 

Contractor shall provide, but not limited to, all labor, materials, and equipment required for all work as described in SIR 6973GH-24-R-00121 and all attachments/documents.

Section L- Instruction, Conditions, and Notices to Bidders

Section M-Evaluation Factors for Award

Proposal shall be submitted by the due date and time to the following email address: Contracting Officer Elizabeth Fikes/Elizabeth.A.Fikes@faa.gov.

CAUTION: The name and address of your firm on the proposal MUST EXACTLY MATCH the address used for your UEI number/SAM registration. Proposals must be received by 5:00 p.m. Central (Oklahoma Time) June 28, 2024, or as amended. Early submission is acceptable.

Update #10 ·

AMENDMENT 0005:

The purpose of Amendment 0005 is as follows:

  1. Questions and Answers/Substitution Requests dated July 12, 2024, is incorporated as Attachment 15, Questions and Answers_7.12.24_6973GH-24-R-00121_VTD

        2. The following pdf attachments are incorporated in amendment 0005.

Attachment 16 - FAA VTD Upgrades-Roofing SubReq_SA-APP

Attachment 17 - Submittal24-33387-0-581343-SA_APP_LDG

Attachment 18 - MMAC VTP Storefront Substitution Request  [17677]-SA_AAN

       3. Attachment 10 – Past Performance Survey is corrected and incorporated in this amendment.

END OF AMENDMENT 0005

***************************************************************************************************************************************************

AMENDMENT 0004:

Proposal due date is extended to Friday, July 17, 2024 at 1700 CDT to allow submitted questions to be answered.

END OF AMENDMENT 0004

***************************************************************************************************************************************************

AMENDMENT 0003:

Proposal due date is extended to Friday, July 5, 2024 at 1700 CDT to allow submitted questions to be answered.

END OF AMENDMENT 0003

***************************************************************************************************************************************************

UPDATE:

June 18, 2024 Site Visit sign-in sheet added to attachments.

END OF UPDATE

***************************************************************************************************************************************************

June 12, 2024 AMENDMENT 0002

The purpose of Amendment 0002 is to establish an additional site visit to include roof access, add the June 6, 2024 site visit sign-in sheet, and extend the date when questions are due as follows:

1. Additional Site Visit will be held on Tuesday, June 18, 2024 at 11:30 a.m. CDT. Participants will meet at the MMAC Visitor Center between 11:15-11:30 a.m. CDT.

2. Questions must be submitted to elizabeth.a.fikes@faa.gov no later than Friday, June 21, 2024 at 5:00 p.m. CDT.

END OF AMENDMENT 0002

***************************************************************************************************************************************************

June 6, 2024 AMENDMENT 0001

The purpose of Amendment 0001 is to correct the contract number listed on Attachment 10-Past Performance Survey in Section J.

END OF AMENDMENT 0001

******************************************************************************************************************************************************

June 5, 2024 UPDATE:

Site Visit meeting will start at the MMAC Visitors Center. Meet at 0915 then we will drive to the site. There is only 1 (one) visitor center. 

END OF UPDATE

***************************************************************************************************************************************************

June 4, 2024 UPDATE:

Email address in Section L paragraph L.1(f) is corrected as follows:

TO:

(f) FAA personnel who will be evaluating proposals received in response to this SIR are working remotely; therefore, offerors should keep this in mind when preparing and submitting proposals. Documentation shall be submitted electronically in accordance with Section L, Clause 3.2.2.3-20, Electronic Offers. Note: Proposal Sections I and II shall be submitted as separate documents. NOTE: Due to FAA email size limitations, it is highly recommended that offerors submit their email proposal for each volume as separate emails and in the email subject line state 6973GH-4-R-00121, Section “**” Submitted on Behalf of “**”. PROPOSALS MUST BE EMAIL TO Elizabeth.a.fikes@faa.gov.

FROM:

(f) FAA personnel who will be evaluating proposals received in response to this SIR are working remotely; therefore, offerors should keep this in mind when preparing and submitting proposals. Documentation shall be submitted electronically in accordance with Section L, Clause 3.2.2.3-20, Electronic Offers. Note: Proposal Sections I and II shall be submitted as separate documents. NOTE: Due to FAA email size limitations, it is highly recommended that offerors submit their email proposal for each volume as separate emails and in the email subject line state 6973GH-4-R-00121, Section “**” Submitted on Behalf of “**”. PROPOSALS MUST BE EMAIL TO Elizabeth.a.fikes@us.af.mil.

END OF UPDATE

************************************************************************************************************************************************

May 31, 2024 UPDATE:

Section L paragraph L.1(b) has changed as follows:

TO:

(b) Offerors are allowed to send a maximum of THREE individuals to represent their proposal (to include proposal teams, if applicable). Please advise the Contract Specialist (Elizabeth Fikes, Elizabeth.a.fikes@faa.gov) in writing of your intent to attend by 5:00 p.m. Central Time, Monday, June 3, 2024. Telephone requests will NOT count as notification of attendance. The Contracting Officer will send out information no later than 11:00 a.m., Wednesday, June 5, 2024, to ONLY those that have provided the required response information. Your request should include the following information:

FROM:

(b) Offerors are allowed to send a maximum of ONE individual to represent their proposal (to include proposal teams, if applicable). Please advise the Contract Specialist (Elizabeth Fikes, Elizabeth.a.fikes@faa.gov) in writing of your intent to attend by 5:00 p.m. Central Time, Monday, June 3, 2024. Telephone requests will NOT count as notification of attendance. The Contracting Officer will send out information no later than 11:00 a.m., Wednesday, June 5, 2024, to ONLY those that have provided the required response information. Your request should include the following information:

END OF UPDATE

************************************************************************************************************************************************

This is a solicitation to assist the FAA in meeting the VTD Upgrade requirement at the Mike Monroney Aeronautical Center in Oklahoma City, OK and includes:

1. Description of Facility:

1.1 Building Area: 24,531 SF

1.2 Building Age: 11-1-1996

1.3 Building Function: Training, classrooms, administration spaces, etc.

1.4 The construction site address is: VTD B204, 7600 Quesada Drive, Oklahoma City, OK 73169.

2. Description of Work:

2.1 Upgrade heating, ventilating, and air-conditioning (HVAC) systems in the VTD facility.

Two (2EA) 100 Ton air-cooled chillers located in the outside the mechanical yard are being updated under separate contract.

2.2 Two (2EA) constant volume primary chilled water pumps (PCHW), two (2EA) variable flow secondary CHW pumps (SCHWPs), two (2EA) variable air volume air handling units (VAV AHUs), two (2EA) computer room air-conditioning units (CRACs), etc. Existing JCI Metasys campus-wide energy management control system (EMCS) will be updated.

2.3 Site drainage is being re-worked and a new natural gas piping to be installed. Replace existing diesel engine generator with a natural-gas engine generator. 

Contractor shall provide, but not limited to, all labor, materials, and equipment required for all work as described in SIR 6973GH-24-R-00121 and all attachments/documents.

Section L- Instruction, Conditions, and Notices to Bidders

Section M-Evaluation Factors for Award

Proposal shall be submitted by the due date and time to the following email address: Contracting Officer Elizabeth Fikes/Elizabeth.A.Fikes@faa.gov.

CAUTION: The name and address of your firm on the proposal MUST EXACTLY MATCH the address used for your UEI number/SAM registration. Proposals must be received by 5:00 p.m. Central (Oklahoma Time) June 28, 2024, or as amended. Early submission is acceptable.

Update #9 ·

AMENDMENT 0004:

Proposal due date is extended to Friday, July 17, 2024 at 1700 CDT to allow submitted questions to be answered.

END OF AMENDMENT 0004

***************************************************************************************************************************************************

AMENDMENT 0003:

Proposal due date is extended to Friday, July 5, 2024 at 1700 CDT to allow submitted questions to be answered.

END OF AMENDMENT 0003

***************************************************************************************************************************************************

UPDATE:

June 18, 2024 Site Visit sign-in sheet added to attachments.

END OF UPDATE

***************************************************************************************************************************************************

June 12, 2024 AMENDMENT 0002

The purpose of Amendment 0002 is to establish an additional site visit to include roof access, add the June 6, 2024 site visit sign-in sheet, and extend the date when questions are due as follows:

1. Additional Site Visit will be held on Tuesday, June 18, 2024 at 11:30 a.m. CDT. Participants will meet at the MMAC Visitor Center between 11:15-11:30 a.m. CDT.

2. Questions must be submitted to elizabeth.a.fikes@faa.gov no later than Friday, June 21, 2024 at 5:00 p.m. CDT.

END OF AMENDMENT 0002

***************************************************************************************************************************************************

June 6, 2024 AMENDMENT 0001

The purpose of Amendment 0001 is to correct the contract number listed on Attachment 10-Past Performance Survey in Section J.

END OF AMENDMENT 0001

******************************************************************************************************************************************************

June 5, 2024 UPDATE:

Site Visit meeting will start at the MMAC Visitors Center. Meet at 0915 then we will drive to the site. There is only 1 (one) visitor center. 

END OF UPDATE

***************************************************************************************************************************************************

June 4, 2024 UPDATE:

Email address in Section L paragraph L.1(f) is corrected as follows:

TO:

(f) FAA personnel who will be evaluating proposals received in response to this SIR are working remotely; therefore, offerors should keep this in mind when preparing and submitting proposals. Documentation shall be submitted electronically in accordance with Section L, Clause 3.2.2.3-20, Electronic Offers. Note: Proposal Sections I and II shall be submitted as separate documents. NOTE: Due to FAA email size limitations, it is highly recommended that offerors submit their email proposal for each volume as separate emails and in the email subject line state 6973GH-4-R-00121, Section “**” Submitted on Behalf of “**”. PROPOSALS MUST BE EMAIL TO Elizabeth.a.fikes@faa.gov.

FROM:

(f) FAA personnel who will be evaluating proposals received in response to this SIR are working remotely; therefore, offerors should keep this in mind when preparing and submitting proposals. Documentation shall be submitted electronically in accordance with Section L, Clause 3.2.2.3-20, Electronic Offers. Note: Proposal Sections I and II shall be submitted as separate documents. NOTE: Due to FAA email size limitations, it is highly recommended that offerors submit their email proposal for each volume as separate emails and in the email subject line state 6973GH-4-R-00121, Section “**” Submitted on Behalf of “**”. PROPOSALS MUST BE EMAIL TO Elizabeth.a.fikes@us.af.mil.

END OF UPDATE

************************************************************************************************************************************************

May 31, 2024 UPDATE:

Section L paragraph L.1(b) has changed as follows:

TO:

(b) Offerors are allowed to send a maximum of THREE individuals to represent their proposal (to include proposal teams, if applicable). Please advise the Contract Specialist (Elizabeth Fikes, Elizabeth.a.fikes@faa.gov) in writing of your intent to attend by 5:00 p.m. Central Time, Monday, June 3, 2024. Telephone requests will NOT count as notification of attendance. The Contracting Officer will send out information no later than 11:00 a.m., Wednesday, June 5, 2024, to ONLY those that have provided the required response information. Your request should include the following information:

FROM:

(b) Offerors are allowed to send a maximum of ONE individual to represent their proposal (to include proposal teams, if applicable). Please advise the Contract Specialist (Elizabeth Fikes, Elizabeth.a.fikes@faa.gov) in writing of your intent to attend by 5:00 p.m. Central Time, Monday, June 3, 2024. Telephone requests will NOT count as notification of attendance. The Contracting Officer will send out information no later than 11:00 a.m., Wednesday, June 5, 2024, to ONLY those that have provided the required response information. Your request should include the following information:

END OF UPDATE

************************************************************************************************************************************************

This is a solicitation to assist the FAA in meeting the VTD Upgrade requirement at the Mike Monroney Aeronautical Center in Oklahoma City, OK and includes:

1. Description of Facility:

1.1 Building Area: 24,531 SF

1.2 Building Age: 11-1-1996

1.3 Building Function: Training, classrooms, administration spaces, etc.

1.4 The construction site address is: VTD B204, 7600 Quesada Drive, Oklahoma City, OK 73169.

2. Description of Work:

2.1 Upgrade heating, ventilating, and air-conditioning (HVAC) systems in the VTD facility.

Two (2EA) 100 Ton air-cooled chillers located in the outside the mechanical yard are being updated under separate contract.

2.2 Two (2EA) constant volume primary chilled water pumps (PCHW), two (2EA) variable flow secondary CHW pumps (SCHWPs), two (2EA) variable air volume air handling units (VAV AHUs), two (2EA) computer room air-conditioning units (CRACs), etc. Existing JCI Metasys campus-wide energy management control system (EMCS) will be updated.

2.3 Site drainage is being re-worked and a new natural gas piping to be installed. Replace existing diesel engine generator with a natural-gas engine generator. 

Contractor shall provide, but not limited to, all labor, materials, and equipment required for all work as described in SIR 6973GH-24-R-00121 and all attachments/documents.

Section L- Instruction, Conditions, and Notices to Bidders

Section M-Evaluation Factors for Award

Proposal shall be submitted by the due date and time to the following email address: Contracting Officer Elizabeth Fikes/Elizabeth.A.Fikes@faa.gov.

CAUTION: The name and address of your firm on the proposal MUST EXACTLY MATCH the address used for your UEI number/SAM registration. Proposals must be received by 5:00 p.m. Central (Oklahoma Time) June 28, 2024, or as amended. Early submission is acceptable.

Update #8 ·

AMENDMENT 0003:

Proposal due date is extended to Friday, July 5, 2024 at 1700 CDT to allow submitted questions to be answered.

END OF AMENDMENT 0003

***************************************************************************************************************************************************

UPDATE:

June 18, 2024 Site Visit sign-in sheet added to attachments.

END OF UPDATE

***************************************************************************************************************************************************

June 12, 2024 AMENDMENT 0002

The purpose of Amendment 0002 is to establish an additional site visit to include roof access, add the June 6, 2024 site visit sign-in sheet, and extend the date when questions are due as follows:

1. Additional Site Visit will be held on Tuesday, June 18, 2024 at 11:30 a.m. CDT. Participants will meet at the MMAC Visitor Center between 11:15-11:30 a.m. CDT.

2. Questions must be submitted to elizabeth.a.fikes@faa.gov no later than Friday, June 21, 2024 at 5:00 p.m. CDT.

END OF AMENDMENT 0002

***************************************************************************************************************************************************

June 6, 2024 AMENDMENT 0001

The purpose of Amendment 0001 is to correct the contract number listed on Attachment 10-Past Performance Survey in Section J.

END OF AMENDMENT 0001

******************************************************************************************************************************************************

June 5, 2024 UPDATE:

Site Visit meeting will start at the MMAC Visitors Center. Meet at 0915 then we will drive to the site. There is only 1 (one) visitor center. 

END OF UPDATE

***************************************************************************************************************************************************

June 4, 2024 UPDATE:

Email address in Section L paragraph L.1(f) is corrected as follows:

TO:

(f) FAA personnel who will be evaluating proposals received in response to this SIR are working remotely; therefore, offerors should keep this in mind when preparing and submitting proposals. Documentation shall be submitted electronically in accordance with Section L, Clause 3.2.2.3-20, Electronic Offers. Note: Proposal Sections I and II shall be submitted as separate documents. NOTE: Due to FAA email size limitations, it is highly recommended that offerors submit their email proposal for each volume as separate emails and in the email subject line state 6973GH-4-R-00121, Section “**” Submitted on Behalf of “**”. PROPOSALS MUST BE EMAIL TO Elizabeth.a.fikes@faa.gov.

FROM:

(f) FAA personnel who will be evaluating proposals received in response to this SIR are working remotely; therefore, offerors should keep this in mind when preparing and submitting proposals. Documentation shall be submitted electronically in accordance with Section L, Clause 3.2.2.3-20, Electronic Offers. Note: Proposal Sections I and II shall be submitted as separate documents. NOTE: Due to FAA email size limitations, it is highly recommended that offerors submit their email proposal for each volume as separate emails and in the email subject line state 6973GH-4-R-00121, Section “**” Submitted on Behalf of “**”. PROPOSALS MUST BE EMAIL TO Elizabeth.a.fikes@us.af.mil.

END OF UPDATE

************************************************************************************************************************************************

May 31, 2024 UPDATE:

Section L paragraph L.1(b) has changed as follows:

TO:

(b) Offerors are allowed to send a maximum of THREE individuals to represent their proposal (to include proposal teams, if applicable). Please advise the Contract Specialist (Elizabeth Fikes, Elizabeth.a.fikes@faa.gov) in writing of your intent to attend by 5:00 p.m. Central Time, Monday, June 3, 2024. Telephone requests will NOT count as notification of attendance. The Contracting Officer will send out information no later than 11:00 a.m., Wednesday, June 5, 2024, to ONLY those that have provided the required response information. Your request should include the following information:

FROM:

(b) Offerors are allowed to send a maximum of ONE individual to represent their proposal (to include proposal teams, if applicable). Please advise the Contract Specialist (Elizabeth Fikes, Elizabeth.a.fikes@faa.gov) in writing of your intent to attend by 5:00 p.m. Central Time, Monday, June 3, 2024. Telephone requests will NOT count as notification of attendance. The Contracting Officer will send out information no later than 11:00 a.m., Wednesday, June 5, 2024, to ONLY those that have provided the required response information. Your request should include the following information:

END OF UPDATE

************************************************************************************************************************************************

This is a solicitation to assist the FAA in meeting the VTD Upgrade requirement at the Mike Monroney Aeronautical Center in Oklahoma City, OK and includes:

1. Description of Facility:

1.1 Building Area: 24,531 SF

1.2 Building Age: 11-1-1996

1.3 Building Function: Training, classrooms, administration spaces, etc.

1.4 The construction site address is: VTD B204, 7600 Quesada Drive, Oklahoma City, OK 73169.

2. Description of Work:

2.1 Upgrade heating, ventilating, and air-conditioning (HVAC) systems in the VTD facility.

Two (2EA) 100 Ton air-cooled chillers located in the outside the mechanical yard are being updated under separate contract.

2.2 Two (2EA) constant volume primary chilled water pumps (PCHW), two (2EA) variable flow secondary CHW pumps (SCHWPs), two (2EA) variable air volume air handling units (VAV AHUs), two (2EA) computer room air-conditioning units (CRACs), etc. Existing JCI Metasys campus-wide energy management control system (EMCS) will be updated.

2.3 Site drainage is being re-worked and a new natural gas piping to be installed. Replace existing diesel engine generator with a natural-gas engine generator. 

Contractor shall provide, but not limited to, all labor, materials, and equipment required for all work as described in SIR 6973GH-24-R-00121 and all attachments/documents.

Section L- Instruction, Conditions, and Notices to Bidders

Section M-Evaluation Factors for Award

Proposal shall be submitted by the due date and time to the following email address: Contracting Officer Elizabeth Fikes/Elizabeth.A.Fikes@faa.gov.

CAUTION: The name and address of your firm on the proposal MUST EXACTLY MATCH the address used for your UEI number/SAM registration. Proposals must be received by 5:00 p.m. Central (Oklahoma Time) June 28, 2024, or as amended. Early submission is acceptable.

Update #7 ·

UPDATE:

June 18, 2024 Site Visit sign-in sheet added to attachments.

END OF UPDATE

***************************************************************************************************************************************************

June 12, 2024 AMENDMENT 0002

The purpose of Amendment 0002 is to establish an additional site visit to include roof access, add the June 6, 2024 site visit sign-in sheet, and extend the date when questions are due as follows:

1. Additional Site Visit will be held on Tuesday, June 18, 2024 at 11:30 a.m. CDT. Participants will meet at the MMAC Visitor Center between 11:15-11:30 a.m. CDT.

2. Questions must be submitted to elizabeth.a.fikes@faa.gov no later than Friday, June 21, 2024 at 5:00 p.m. CDT.

END OF AMENDMENT 0002

***************************************************************************************************************************************************

June 6, 2024 AMENDMENT 0001

The purpose of Amendment 0001 is to correct the contract number listed on Attachment 10-Past Performance Survey in Section J.

END OF AMENDMENT 0001

******************************************************************************************************************************************************

June 5, 2024 UPDATE:

Site Visit meeting will start at the MMAC Visitors Center. Meet at 0915 then we will drive to the site. There is only 1 (one) visitor center. 

END OF UPDATE

***************************************************************************************************************************************************

June 4, 2024 UPDATE:

Email address in Section L paragraph L.1(f) is corrected as follows:

TO:

(f) FAA personnel who will be evaluating proposals received in response to this SIR are working remotely; therefore, offerors should keep this in mind when preparing and submitting proposals. Documentation shall be submitted electronically in accordance with Section L, Clause 3.2.2.3-20, Electronic Offers. Note: Proposal Sections I and II shall be submitted as separate documents. NOTE: Due to FAA email size limitations, it is highly recommended that offerors submit their email proposal for each volume as separate emails and in the email subject line state 6973GH-4-R-00121, Section “**” Submitted on Behalf of “**”. PROPOSALS MUST BE EMAIL TO Elizabeth.a.fikes@faa.gov.

FROM:

(f) FAA personnel who will be evaluating proposals received in response to this SIR are working remotely; therefore, offerors should keep this in mind when preparing and submitting proposals. Documentation shall be submitted electronically in accordance with Section L, Clause 3.2.2.3-20, Electronic Offers. Note: Proposal Sections I and II shall be submitted as separate documents. NOTE: Due to FAA email size limitations, it is highly recommended that offerors submit their email proposal for each volume as separate emails and in the email subject line state 6973GH-4-R-00121, Section “**” Submitted on Behalf of “**”. PROPOSALS MUST BE EMAIL TO Elizabeth.a.fikes@us.af.mil.

END OF UPDATE

************************************************************************************************************************************************

May 31, 2024 UPDATE:

Section L paragraph L.1(b) has changed as follows:

TO:

(b) Offerors are allowed to send a maximum of THREE individuals to represent their proposal (to include proposal teams, if applicable). Please advise the Contract Specialist (Elizabeth Fikes, Elizabeth.a.fikes@faa.gov) in writing of your intent to attend by 5:00 p.m. Central Time, Monday, June 3, 2024. Telephone requests will NOT count as notification of attendance. The Contracting Officer will send out information no later than 11:00 a.m., Wednesday, June 5, 2024, to ONLY those that have provided the required response information. Your request should include the following information:

FROM:

(b) Offerors are allowed to send a maximum of ONE individual to represent their proposal (to include proposal teams, if applicable). Please advise the Contract Specialist (Elizabeth Fikes, Elizabeth.a.fikes@faa.gov) in writing of your intent to attend by 5:00 p.m. Central Time, Monday, June 3, 2024. Telephone requests will NOT count as notification of attendance. The Contracting Officer will send out information no later than 11:00 a.m., Wednesday, June 5, 2024, to ONLY those that have provided the required response information. Your request should include the following information:

END OF UPDATE

************************************************************************************************************************************************

This is a solicitation to assist the FAA in meeting the VTD Upgrade requirement at the Mike Monroney Aeronautical Center in Oklahoma City, OK and includes:

1. Description of Facility:

1.1 Building Area: 24,531 SF

1.2 Building Age: 11-1-1996

1.3 Building Function: Training, classrooms, administration spaces, etc.

1.4 The construction site address is: VTD B204, 7600 Quesada Drive, Oklahoma City, OK 73169.

2. Description of Work:

2.1 Upgrade heating, ventilating, and air-conditioning (HVAC) systems in the VTD facility.

Two (2EA) 100 Ton air-cooled chillers located in the outside the mechanical yard are being updated under separate contract.

2.2 Two (2EA) constant volume primary chilled water pumps (PCHW), two (2EA) variable flow secondary CHW pumps (SCHWPs), two (2EA) variable air volume air handling units (VAV AHUs), two (2EA) computer room air-conditioning units (CRACs), etc. Existing JCI Metasys campus-wide energy management control system (EMCS) will be updated.

2.3 Site drainage is being re-worked and a new natural gas piping to be installed. Replace existing diesel engine generator with a natural-gas engine generator. 

Contractor shall provide, but not limited to, all labor, materials, and equipment required for all work as described in SIR 6973GH-24-R-00121 and all attachments/documents.

Section L- Instruction, Conditions, and Notices to Bidders

Section M-Evaluation Factors for Award

Proposal shall be submitted by the due date and time to the following email address: Contracting Officer Elizabeth Fikes/Elizabeth.A.Fikes@faa.gov.

CAUTION: The name and address of your firm on the proposal MUST EXACTLY MATCH the address used for your UEI number/SAM registration. Proposals must be received by 5:00 p.m. Central (Oklahoma Time) June 28, 2024, or as amended. Early submission is acceptable.

Update #6 ·

June 12, 2024 AMENDMENT 0002

The purpose of Amendment 0002 is to establish an additional site visit to include roof access, add the June 6, 2024 site visit sign-in sheet, and extend the date when questions are due as follows:

1. Additional Site Visit will be held on Tuesday, June 18, 2024 at 11:30 a.m. CDT. Participants will meet at the MMAC Visitor Center between 11:15-11:30 a.m. CDT.

2. Questions must be submitted to elizabeth.a.fikes@faa.gov no later than Friday, June 21, 2024 at 5:00 p.m. CDT.

END OF AMENDMENT 0002

***************************************************************************************************************************************************

June 6, 2024 AMENDMENT 0001

The purpose of Amendment 0001 is to correct the contract number listed on Attachment 10-Past Performance Survey in Section J.

END OF AMENDMENT 0001

******************************************************************************************************************************************************

June 5, 2024 UPDATE:

Site Visit meeting will start at the MMAC Visitors Center. Meet at 0915 then we will drive to the site. There is only 1 (one) visitor center. 

END OF UPDATE

***************************************************************************************************************************************************

June 4, 2024 UPDATE:

Email address in Section L paragraph L.1(f) is corrected as follows:

TO:

(f) FAA personnel who will be evaluating proposals received in response to this SIR are working remotely; therefore, offerors should keep this in mind when preparing and submitting proposals. Documentation shall be submitted electronically in accordance with Section L, Clause 3.2.2.3-20, Electronic Offers. Note: Proposal Sections I and II shall be submitted as separate documents. NOTE: Due to FAA email size limitations, it is highly recommended that offerors submit their email proposal for each volume as separate emails and in the email subject line state 6973GH-4-R-00121, Section “**” Submitted on Behalf of “**”. PROPOSALS MUST BE EMAIL TO Elizabeth.a.fikes@faa.gov.

FROM:

(f) FAA personnel who will be evaluating proposals received in response to this SIR are working remotely; therefore, offerors should keep this in mind when preparing and submitting proposals. Documentation shall be submitted electronically in accordance with Section L, Clause 3.2.2.3-20, Electronic Offers. Note: Proposal Sections I and II shall be submitted as separate documents. NOTE: Due to FAA email size limitations, it is highly recommended that offerors submit their email proposal for each volume as separate emails and in the email subject line state 6973GH-4-R-00121, Section “**” Submitted on Behalf of “**”. PROPOSALS MUST BE EMAIL TO Elizabeth.a.fikes@us.af.mil.

END OF UPDATE

************************************************************************************************************************************************

May 31, 2024 UPDATE:

Section L paragraph L.1(b) has changed as follows:

TO:

(b) Offerors are allowed to send a maximum of THREE individuals to represent their proposal (to include proposal teams, if applicable). Please advise the Contract Specialist (Elizabeth Fikes, Elizabeth.a.fikes@faa.gov) in writing of your intent to attend by 5:00 p.m. Central Time, Monday, June 3, 2024. Telephone requests will NOT count as notification of attendance. The Contracting Officer will send out information no later than 11:00 a.m., Wednesday, June 5, 2024, to ONLY those that have provided the required response information. Your request should include the following information:

FROM:

(b) Offerors are allowed to send a maximum of ONE individual to represent their proposal (to include proposal teams, if applicable). Please advise the Contract Specialist (Elizabeth Fikes, Elizabeth.a.fikes@faa.gov) in writing of your intent to attend by 5:00 p.m. Central Time, Monday, June 3, 2024. Telephone requests will NOT count as notification of attendance. The Contracting Officer will send out information no later than 11:00 a.m., Wednesday, June 5, 2024, to ONLY those that have provided the required response information. Your request should include the following information:

END OF UPDATE

************************************************************************************************************************************************

This is a solicitation to assist the FAA in meeting the VTD Upgrade requirement at the Mike Monroney Aeronautical Center in Oklahoma City, OK and includes:

1. Description of Facility:

1.1 Building Area: 24,531 SF

1.2 Building Age: 11-1-1996

1.3 Building Function: Training, classrooms, administration spaces, etc.

1.4 The construction site address is: VTD B204, 7600 Quesada Drive, Oklahoma City, OK 73169.

2. Description of Work:

2.1 Upgrade heating, ventilating, and air-conditioning (HVAC) systems in the VTD facility.

Two (2EA) 100 Ton air-cooled chillers located in the outside the mechanical yard are being updated under separate contract.

2.2 Two (2EA) constant volume primary chilled water pumps (PCHW), two (2EA) variable flow secondary CHW pumps (SCHWPs), two (2EA) variable air volume air handling units (VAV AHUs), two (2EA) computer room air-conditioning units (CRACs), etc. Existing JCI Metasys campus-wide energy management control system (EMCS) will be updated.

2.3 Site drainage is being re-worked and a new natural gas piping to be installed. Replace existing diesel engine generator with a natural-gas engine generator. 

Contractor shall provide, but not limited to, all labor, materials, and equipment required for all work as described in SIR 6973GH-24-R-00121 and all attachments/documents.

Section L- Instruction, Conditions, and Notices to Bidders

Section M-Evaluation Factors for Award

Proposal shall be submitted by the due date and time to the following email address: Contracting Officer Elizabeth Fikes/Elizabeth.A.Fikes@faa.gov.

CAUTION: The name and address of your firm on the proposal MUST EXACTLY MATCH the address used for your UEI number/SAM registration. Proposals must be received by 5:00 p.m. Central (Oklahoma Time) June 28, 2024, or as amended. Early submission is acceptable.

Update #5 ·

June 6, 2024 AMENDMENT 0001

The purpose of Amendment 0001 is to correct the contract number listed on Attachment 10-Past Performance Survey in Section J.

END OF AMENDMENT 0001

******************************************************************************************************************************************************

June 5, 2024 UPDATE:

Site Visit meeting will start at the MMAC Visitors Center. Meet at 0915 then we will drive to the site. There is only 1 (one) visitor center. 

END OF UPDATE

***************************************************************************************************************************************************

June 4, 2024 UPDATE:

Email address in Section L paragraph L.1(f) is corrected as follows:

TO:

(f) FAA personnel who will be evaluating proposals received in response to this SIR are working remotely; therefore, offerors should keep this in mind when preparing and submitting proposals. Documentation shall be submitted electronically in accordance with Section L, Clause 3.2.2.3-20, Electronic Offers. Note: Proposal Sections I and II shall be submitted as separate documents. NOTE: Due to FAA email size limitations, it is highly recommended that offerors submit their email proposal for each volume as separate emails and in the email subject line state 6973GH-4-R-00121, Section “**” Submitted on Behalf of “**”. PROPOSALS MUST BE EMAIL TO Elizabeth.a.fikes@faa.gov.

FROM:

(f) FAA personnel who will be evaluating proposals received in response to this SIR are working remotely; therefore, offerors should keep this in mind when preparing and submitting proposals. Documentation shall be submitted electronically in accordance with Section L, Clause 3.2.2.3-20, Electronic Offers. Note: Proposal Sections I and II shall be submitted as separate documents. NOTE: Due to FAA email size limitations, it is highly recommended that offerors submit their email proposal for each volume as separate emails and in the email subject line state 6973GH-4-R-00121, Section “**” Submitted on Behalf of “**”. PROPOSALS MUST BE EMAIL TO Elizabeth.a.fikes@us.af.mil.

END OF UPDATE

************************************************************************************************************************************************

May 31, 2024 UPDATE:

Section L paragraph L.1(b) has changed as follows:

TO:

(b) Offerors are allowed to send a maximum of THREE individuals to represent their proposal (to include proposal teams, if applicable). Please advise the Contract Specialist (Elizabeth Fikes, Elizabeth.a.fikes@faa.gov) in writing of your intent to attend by 5:00 p.m. Central Time, Monday, June 3, 2024. Telephone requests will NOT count as notification of attendance. The Contracting Officer will send out information no later than 11:00 a.m., Wednesday, June 5, 2024, to ONLY those that have provided the required response information. Your request should include the following information:

FROM:

(b) Offerors are allowed to send a maximum of ONE individual to represent their proposal (to include proposal teams, if applicable). Please advise the Contract Specialist (Elizabeth Fikes, Elizabeth.a.fikes@faa.gov) in writing of your intent to attend by 5:00 p.m. Central Time, Monday, June 3, 2024. Telephone requests will NOT count as notification of attendance. The Contracting Officer will send out information no later than 11:00 a.m., Wednesday, June 5, 2024, to ONLY those that have provided the required response information. Your request should include the following information:

END OF UPDATE

************************************************************************************************************************************************

This is a solicitation to assist the FAA in meeting the VTD Upgrade requirement at the Mike Monroney Aeronautical Center in Oklahoma City, OK and includes:

1. Description of Facility:

1.1 Building Area: 24,531 SF

1.2 Building Age: 11-1-1996

1.3 Building Function: Training, classrooms, administration spaces, etc.

1.4 The construction site address is: VTD B204, 7600 Quesada Drive, Oklahoma City, OK 73169.

2. Description of Work:

2.1 Upgrade heating, ventilating, and air-conditioning (HVAC) systems in the VTD facility.

Two (2EA) 100 Ton air-cooled chillers located in the outside the mechanical yard are being updated under separate contract.

2.2 Two (2EA) constant volume primary chilled water pumps (PCHW), two (2EA) variable flow secondary CHW pumps (SCHWPs), two (2EA) variable air volume air handling units (VAV AHUs), two (2EA) computer room air-conditioning units (CRACs), etc. Existing JCI Metasys campus-wide energy management control system (EMCS) will be updated.

2.3 Site drainage is being re-worked and a new natural gas piping to be installed. Replace existing diesel engine generator with a natural-gas engine generator. 

Contractor shall provide, but not limited to, all labor, materials, and equipment required for all work as described in SIR 6973GH-24-R-00121 and all attachments/documents.

Section L- Instruction, Conditions, and Notices to Bidders

Section M-Evaluation Factors for Award

Proposal shall be submitted by the due date and time to the following email address: Contracting Officer Elizabeth Fikes/Elizabeth.A.Fikes@faa.gov.

CAUTION: The name and address of your firm on the proposal MUST EXACTLY MATCH the address used for your UEI number/SAM registration. Proposals must be received by 5:00 p.m. Central (Oklahoma Time) June 28, 2024, or as amended. Early submission is acceptable.

Update #4 ·

June 5, 2024 UPDATE:

Site Visit meeting will start at the MMAC Visitors Center. Meet at 0915 then we will drive to the site. There is only 1 (one) visitor center. 

END OF UPDATE

***************************************************************************************************************************************************

June 4, 2024 UPDATE:

Email address in Section L paragraph L.1(f) is corrected as follows:

TO:

(f) FAA personnel who will be evaluating proposals received in response to this SIR are working remotely; therefore, offerors should keep this in mind when preparing and submitting proposals. Documentation shall be submitted electronically in accordance with Section L, Clause 3.2.2.3-20, Electronic Offers. Note: Proposal Sections I and II shall be submitted as separate documents. NOTE: Due to FAA email size limitations, it is highly recommended that offerors submit their email proposal for each volume as separate emails and in the email subject line state 6973GH-4-R-00121, Section “**” Submitted on Behalf of “**”. PROPOSALS MUST BE EMAIL TO Elizabeth.a.fikes@faa.gov.

FROM:

(f) FAA personnel who will be evaluating proposals received in response to this SIR are working remotely; therefore, offerors should keep this in mind when preparing and submitting proposals. Documentation shall be submitted electronically in accordance with Section L, Clause 3.2.2.3-20, Electronic Offers. Note: Proposal Sections I and II shall be submitted as separate documents. NOTE: Due to FAA email size limitations, it is highly recommended that offerors submit their email proposal for each volume as separate emails and in the email subject line state 6973GH-4-R-00121, Section “**” Submitted on Behalf of “**”. PROPOSALS MUST BE EMAIL TO Elizabeth.a.fikes@us.af.mil.

END OF UPDATE

************************************************************************************************************************************************

May 31, 2024 UPDATE:

Section L paragraph L.1(b) has changed as follows:

TO:

(b) Offerors are allowed to send a maximum of THREE individuals to represent their proposal (to include proposal teams, if applicable). Please advise the Contract Specialist (Elizabeth Fikes, Elizabeth.a.fikes@faa.gov) in writing of your intent to attend by 5:00 p.m. Central Time, Monday, June 3, 2024. Telephone requests will NOT count as notification of attendance. The Contracting Officer will send out information no later than 11:00 a.m., Wednesday, June 5, 2024, to ONLY those that have provided the required response information. Your request should include the following information:

FROM:

(b) Offerors are allowed to send a maximum of ONE individual to represent their proposal (to include proposal teams, if applicable). Please advise the Contract Specialist (Elizabeth Fikes, Elizabeth.a.fikes@faa.gov) in writing of your intent to attend by 5:00 p.m. Central Time, Monday, June 3, 2024. Telephone requests will NOT count as notification of attendance. The Contracting Officer will send out information no later than 11:00 a.m., Wednesday, June 5, 2024, to ONLY those that have provided the required response information. Your request should include the following information:

END OF UPDATE

************************************************************************************************************************************************

This is a solicitation to assist the FAA in meeting the VTD Upgrade requirement at the Mike Monroney Aeronautical Center in Oklahoma City, OK and includes:

1. Description of Facility:

1.1 Building Area: 24,531 SF

1.2 Building Age: 11-1-1996

1.3 Building Function: Training, classrooms, administration spaces, etc.

1.4 The construction site address is: VTD B204, 7600 Quesada Drive, Oklahoma City, OK 73169.

2. Description of Work:

2.1 Upgrade heating, ventilating, and air-conditioning (HVAC) systems in the VTD facility.

Two (2EA) 100 Ton air-cooled chillers located in the outside the mechanical yard are being updated under separate contract.

2.2 Two (2EA) constant volume primary chilled water pumps (PCHW), two (2EA) variable flow secondary CHW pumps (SCHWPs), two (2EA) variable air volume air handling units (VAV AHUs), two (2EA) computer room air-conditioning units (CRACs), etc. Existing JCI Metasys campus-wide energy management control system (EMCS) will be updated.

2.3 Site drainage is being re-worked and a new natural gas piping to be installed. Replace existing diesel engine generator with a natural-gas engine generator. 

Contractor shall provide, but not limited to, all labor, materials, and equipment required for all work as described in SIR 6973GH-24-R-00121 and all attachments/documents.

Section L- Instruction, Conditions, and Notices to Bidders

Section M-Evaluation Factors for Award

Proposal shall be submitted by the due date and time to the following email address: Contracting Officer Elizabeth Fikes/Elizabeth.A.Fikes@faa.gov.

CAUTION: The name and address of your firm on the proposal MUST EXACTLY MATCH the address used for your UEI number/SAM registration. Proposals must be received by 5:00 p.m. Central (Oklahoma Time) June 28, 2024, or as amended. Early submission is acceptable.

Update #3 ·

June 4, 2024 UPDATE:

Email address in Section L paragraph L.1(f) is corrected as follows:

TO:

(f) FAA personnel who will be evaluating proposals received in response to this SIR are working remotely; therefore, offerors should keep this in mind when preparing and submitting proposals. Documentation shall be submitted electronically in accordance with Section L, Clause 3.2.2.3-20, Electronic Offers. Note: Proposal Sections I and II shall be submitted as separate documents. NOTE: Due to FAA email size limitations, it is highly recommended that offerors submit their email proposal for each volume as separate emails and in the email subject line state 6973GH-4-R-00121, Section “**” Submitted on Behalf of “**”. PROPOSALS MUST BE EMAIL TO Elizabeth.a.fikes@faa.gov.

FROM:

(f) FAA personnel who will be evaluating proposals received in response to this SIR are working remotely; therefore, offerors should keep this in mind when preparing and submitting proposals. Documentation shall be submitted electronically in accordance with Section L, Clause 3.2.2.3-20, Electronic Offers. Note: Proposal Sections I and II shall be submitted as separate documents. NOTE: Due to FAA email size limitations, it is highly recommended that offerors submit their email proposal for each volume as separate emails and in the email subject line state 6973GH-4-R-00121, Section “**” Submitted on Behalf of “**”. PROPOSALS MUST BE EMAIL TO Elizabeth.a.fikes@us.af.mil.

END OF UPDATE

************************************************************************************************************************************************

May 31, 2024 UPDATE:

Section L paragraph L.1(b) has changed as follows:

TO:

(b) Offerors are allowed to send a maximum of THREE individuals to represent their proposal (to include proposal teams, if applicable). Please advise the Contract Specialist (Elizabeth Fikes, Elizabeth.a.fikes@faa.gov) in writing of your intent to attend by 5:00 p.m. Central Time, Monday, June 3, 2024. Telephone requests will NOT count as notification of attendance. The Contracting Officer will send out information no later than 11:00 a.m., Wednesday, June 5, 2024, to ONLY those that have provided the required response information. Your request should include the following information:

FROM:

(b) Offerors are allowed to send a maximum of ONE individual to represent their proposal (to include proposal teams, if applicable). Please advise the Contract Specialist (Elizabeth Fikes, Elizabeth.a.fikes@faa.gov) in writing of your intent to attend by 5:00 p.m. Central Time, Monday, June 3, 2024. Telephone requests will NOT count as notification of attendance. The Contracting Officer will send out information no later than 11:00 a.m., Wednesday, June 5, 2024, to ONLY those that have provided the required response information. Your request should include the following information:

END OF UPDATE

************************************************************************************************************************************************

This is a solicitation to assist the FAA in meeting the VTD Upgrade requirement at the Mike Monroney Aeronautical Center in Oklahoma City, OK and includes:

1. Description of Facility:

1.1 Building Area: 24,531 SF

1.2 Building Age: 11-1-1996

1.3 Building Function: Training, classrooms, administration spaces, etc.

1.4 The construction site address is: VTD B204, 7600 Quesada Drive, Oklahoma City, OK 73169.

2. Description of Work:

2.1 Upgrade heating, ventilating, and air-conditioning (HVAC) systems in the VTD facility.

Two (2EA) 100 Ton air-cooled chillers located in the outside the mechanical yard are being updated under separate contract.

2.2 Two (2EA) constant volume primary chilled water pumps (PCHW), two (2EA) variable flow secondary CHW pumps (SCHWPs), two (2EA) variable air volume air handling units (VAV AHUs), two (2EA) computer room air-conditioning units (CRACs), etc. Existing JCI Metasys campus-wide energy management control system (EMCS) will be updated.

2.3 Site drainage is being re-worked and a new natural gas piping to be installed. Replace existing diesel engine generator with a natural-gas engine generator. 

Contractor shall provide, but not limited to, all labor, materials, and equipment required for all work as described in SIR 6973GH-24-R-00121 and all attachments/documents.

Section L- Instruction, Conditions, and Notices to Bidders

Section M-Evaluation Factors for Award

Proposal shall be submitted by the due date and time to the following email address: Contracting Officer Elizabeth Fikes/Elizabeth.A.Fikes@faa.gov.

CAUTION: The name and address of your firm on the proposal MUST EXACTLY MATCH the address used for your UEI number/SAM registration. Proposals must be received by 5:00 p.m. Central (Oklahoma Time) June 28, 2024, or as amended. Early submission is acceptable.

Update #2 ·

May 31, 2024 UPDATE:

Section L paragraph L.1(b) has changed as follows:

TO:

(b) Offerors are allowed to send a maximum of THREE individuals to represent their proposal (to include proposal teams, if applicable). Please advise the Contract Specialist (Elizabeth Fikes, Elizabeth.a.fikes@faa.gov) in writing of your intent to attend by 5:00 p.m. Central Time, Monday, June 3, 2024. Telephone requests will NOT count as notification of attendance. The Contracting Officer will send out information no later than 11:00 a.m., Wednesday, June 5, 2024, to ONLY those that have provided the required response information. Your request should include the following information:

FROM:

(b) Offerors are allowed to send a maximum of ONE individual to represent their proposal (to include proposal teams, if applicable). Please advise the Contract Specialist (Elizabeth Fikes, Elizabeth.a.fikes@faa.gov) in writing of your intent to attend by 5:00 p.m. Central Time, Monday, June 3, 2024. Telephone requests will NOT count as notification of attendance. The Contracting Officer will send out information no later than 11:00 a.m., Wednesday, June 5, 2024, to ONLY those that have provided the required response information. Your request should include the following information:

END OF UPDATE

************************************************************************************************************************************************

This is a solicitation to assist the FAA in meeting the VTD Upgrade requirement at the Mike Monroney Aeronautical Center in Oklahoma City, OK and includes:

1. Description of Facility:

1.1 Building Area: 24,531 SF

1.2 Building Age: 11-1-1996

1.3 Building Function: Training, classrooms, administration spaces, etc.

1.4 The construction site address is: VTD B204, 7600 Quesada Drive, Oklahoma City, OK 73169.

2. Description of Work:

2.1 Upgrade heating, ventilating, and air-conditioning (HVAC) systems in the VTD facility.

Two (2EA) 100 Ton air-cooled chillers located in the outside the mechanical yard are being updated under separate contract.

2.2 Two (2EA) constant volume primary chilled water pumps (PCHW), two (2EA) variable flow secondary CHW pumps (SCHWPs), two (2EA) variable air volume air handling units (VAV AHUs), two (2EA) computer room air-conditioning units (CRACs), etc. Existing JCI Metasys campus-wide energy management control system (EMCS) will be updated.

2.3 Site drainage is being re-worked and a new natural gas piping to be installed. Replace existing diesel engine generator with a natural-gas engine generator. 

Contractor shall provide, but not limited to, all labor, materials, and equipment required for all work as described in SIR 6973GH-24-R-00121 and all attachments/documents.

Section L- Instruction, Conditions, and Notices to Bidders

Section M-Evaluation Factors for Award

Proposal shall be submitted by the due date and time to the following email address: Contracting Officer Elizabeth Fikes/Elizabeth.A.Fikes@faa.gov.

CAUTION: The name and address of your firm on the proposal MUST EXACTLY MATCH the address used for your UEI number/SAM registration. Proposals must be received by 5:00 p.m. Central (Oklahoma Time) June 28, 2024, or as amended. Early submission is acceptable.

Update #1 ·

This is a solicitation to assist the FAA in meeting the VTD Upgrade requirement at the Mike Monroney Aeronautical Center in Oklahoma City, OK and includes:

1. Description of Facility:

1.1 Building Area: 24,531 SF

1.2 Building Age: 11-1-1996

1.3 Building Function: Training, classrooms, administration spaces, etc.

1.4 The construction site address is: VTD B204, 7600 Quesada Drive, Oklahoma City, OK 73169.

2. Description of Work:

2.1 Upgrade heating, ventilating, and air-conditioning (HVAC) systems in the VTD facility.

Two (2EA) 100 Ton air-cooled chillers located in the outside the mechanical yard are being updated under separate contract.

2.2 Two (2EA) constant volume primary chilled water pumps (PCHW), two (2EA) variable flow secondary CHW pumps (SCHWPs), two (2EA) variable air volume air handling units (VAV AHUs), two (2EA) computer room air-conditioning units (CRACs), etc. Existing JCI Metasys campus-wide energy management control system (EMCS) will be updated.

2.3 Site drainage is being re-worked and a new natural gas piping to be installed. Replace existing diesel engine generator with a natural-gas engine generator. 

Contractor shall provide, but not limited to, all labor, materials, and equipment required for all work as described in SIR 6973GH-24-R-00121 and all attachments/documents.

Section L- Instruction, Conditions, and Notices to Bidders

Section M-Evaluation Factors for Award

Proposal shall be submitted by the due date and time to the following email address: Contracting Officer Elizabeth Fikes/Elizabeth.A.Fikes@faa.gov.

CAUTION: The name and address of your firm on the proposal MUST EXACTLY MATCH the address used for your UEI number/SAM registration. Proposals must be received by 5:00 p.m. Central (Oklahoma Time) June 28, 2024, or as amended. Early submission is acceptable.

Attachments

Files attached to this notice, newest first
File Type Posted
18.MMAC VTP Storefront Substitution Request [17677]-SA_AAN.pdf PDF
17. Submittal24-33387-0-581343-SA_APP_LDG.pdf PDF
15. Questions and Answers _7.12.24_6973GH-24-R-00121_VTD.pdf PDF
6973GH-24-R-00121-00005.pdf PDF
10. Past Performance Survey-7.12.24.docx DOCX document
6973GH-24-R-00121-0004.pdf PDF
6973GH-24-R-00121-0003.pdf PDF
6-18-24 SIGN-IN SHEET - VTD SITE VISIT - ROOF.pdf PDF
6973GH-24-R-00121-0002.pdf PDF
LIST OF ATTENDEES _PRE-BID SITE VISIT 6-6-24 19-035903 VTD UPGRADEs.pdf PDF
10. Past Performance Survey-6.6.24.docx DOCX document
6973GH-24-R-00121-0001.pdf PDF
4. 19-035903_VTD Upgrades-100%Type B Specifications_240402_REV.pdf PDF
3. 19-035903_VTD Upgrades-100%Type B Drawings_240402_REV.pdf PDF
5. Construction Schedule - 19-035903.pdf PDF
6. AMP400 OC Construction contractors combined.pdf PDF
12. SF 25 Performance Bond.pdf PDF
7. Attachment F-4.pdf PDF
8. Client Authorization Letter.docx DOCX document
11. Wage Determination OK20240049.pdf PDF
13. SF 25A Payment Bond.pdf PDF
6973GH-24-R-00121.pdf PDF
1. Section B - Supplies or Services-Prices.xlsx XLSX spreadsheet
2. SOW 19-035903 VTD Upgrade 5-18-24.pdf PDF
9. Past Performance Experience Information Form.docx DOCX document
10. Past Performance Survey.docx DOCX document
14. Contractor Release.pdf PDF
Show all 27

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
VTD Upgrades Award Award Notice
VTD Upgrades This notice · Latest solicitation Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity