RFQ for Title II for Repair Jones Hall at Keesler AFB

Closed Solicitation Posted

Solicitation number
FA890326R0069
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

NAICS code
541330 Engineering Services
Place of performance
Biloxi, Mississippi 39534, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Air Force Installation Contracting Agency seeks Title II architect-engineer services for repair of Jones Hall (Building B6902) at Keesler AFB, Mississippi, with proposals due July 13, 2026. This RFQ is restricted to AE NEXT Pool 4 contractors and seeks to identify three qualified firms for a Firm Fixed Price Task Order with an estimated 28-month period of performance and award in September 2026.

Place of performance is Keesler AFB, Mississippi (39534). The project involves full-time on-site Quality Assurance construction inspection; review and development of Government responses to construction submittals and Requests for Information; schedule validation documenting earned-value completion; time impact analysis evaluation; and professional architect-engineer and cost-estimating support. The Lead Construction Inspector must hold a degree in Engineering or Construction Management (or 15 years inspection experience with five years as lead), possess a minimum five years construction experience including three years on DoD projects, and maintain current certification in a professionally accredited Quality Control Management Course. A Health and Safety Plan must be submitted prior to on-site work.

The NAICS code is 541330, Engineering Services; PSC is C219. The project's total estimated repair cost is $49.65 million with a repair-to-replacement ratio of 43.48 percent. Evaluation criteria are: confirmed adequate capacity to perform; Specialized Experience on similar complexity DoD installations (Relocatable Facilities, Building Renovation and Systems Upgrades, Hurricane Shelter Upgrades, or Elevator Repairs) demonstrated through SF-330 project profiles from the past five years; Professional Qualifications evidenced through staffing plans and key personnel resumes meeting SOW minimums; and Knowledge of Locality, with priority for prior Keesler AFB and Mississippi experience. The building, constructed in the 1950s–1962 and housing the 338th Squadron and ten cyber training classes, requires hazardous materials abatement (asbestos, lead-containing paint, and mold remediation documented in baseline surveys), complete HVAC replacement, roof replacement, electrical and communications infrastructure replacement, and ICC-500 hurricane shelter upgrades. Proposals should address the Draft SOW but may propose alternative approaches. Funds are not currently available; the Government reserves the right to cancel evaluation with no obligation to reimburse offeror costs. Contracting Officer is Samuel L. Mendez (samuel.mendez@us.af.mil); Contract Specialist is Dalam Siewert (dalam.siewert.1@us.af.mil).

Notice text

This RFQ notice is for the AE NEXT POOL 4 contractors for the Title II Services for Repair Jones Hall B6902 at Keesler AFB, MS requirement. Title II includes on-site Quality Assurance inspections, review and drafting Government responses for all construction submittals and RFIs, validating contractor schedules and earned-value progress, evaluating Time Impact Analyses and proposed PoP changes, and supplying professional A-E and cost-estimating support to ensure the construction contractor complies with the Statement of Work (SOW), specifications, and project requirements in support of the Governments planned Repair Jones Hall B6902 at Keesler AFB, MS. 

Files

File Type Posted
SOW_Title_II_09022026.pdf PDF
Appendix A - Air Force Facilities Sustainability Requirements Scoresheet.xlsx XLSX spreadsheet
Appendix M - Arnold Hall B5901 Restroom As-Builts.pdf PDF
Appendix P - Arnold Hall B5901 Asbestos Inspection Report.pdf PDF
RFQD-TII-Jones Hall - 17 Jun 2026.pdf PDF
Appendix B - Air Force Sustainable Design and Development (SDD) Implementing Guidance.pdf PDF
Appendix F - Keesler Architectural Compatibility Guide (ACG).pdf PDF
Appendix K - Jones Hall B6902 Hazardous Material Survey.pdf PDF
Appendix Q - Jones Hall B6902 Hazardous Materials Report.pdf PDF
Appendix R - Premise Wiring Guidance.pdf PDF
Appendix C - Keesler AFB Installation Facilities Standards (IFS).pdf PDF
Appendix D - Keesler AFB Premise Wiring Guidance.pdf PDF
Appendix E - SWPPP Guidance Manual.pdf PDF
Appendix H - Jones Hall SID Binder.pdf PDF
Appendix H - Jones Hall AFB Drawings Vole 2 of 2_optimized.pdf PDF
Appendix L - Arnold Hall B5901 Drawings.pdf PDF
Appendix N - Arnold Hall B5901 Specifications.pdf PDF
Appendix O - Arnold Hall B5901 Hazardous Material Survey.pdf PDF
Appendix A - Air Force Facilities Sustainability Requirements Scoresheet.xlsx XLSX spreadsheet
Appendix G - Jones Hall B6902 DD Form 1391.pdf PDF
Appendix H - Jones Hall RLF Drawings Vol 1 of 2.pdf PDF
Appendix I - Jones Hall B6902 As-Built.pdf PDF
Appendix J - Jones Hall B6902 100 percent Specifications.pdf PDF
Show all 23