Appendix M - Arnold Hall B5901 Restroom As-Builts.pdf

PDF 673 KB Posted

Attached to
RFQ for Title II for Repair Jones Hall at Keesler AFB
Solicitation number
FA890326R0069
Issued by

About this file

This document is a set of architectural drawings and construction plans for the renovation of Building 5901 at Keesler Air Force Base.

The drawings depict comprehensive renovation work for men's and women's toilet facilities, including detailed floor plans, elevation sections, mechanical systems, and finish schedules. Page 1 contains the overall floor plan with a vicinity map and finish schedule listing materials for various spaces including manager's office, office areas, storage closets, and restrooms with specifications for flooring, base, wainscot, ceiling, and ceiling height. Pages 2-3 show detailed cross-sectional drawings and construction details for wall assemblies, structural elements, plumbing connections, and fixture installations. Page 3 includes mechanical and piping plans for water heater installation and distribution, with a water heater schedule indicating a 75-gallon capacity unit with 4 kW electrical demand and 11.8 GPM efficiency rating. Page 4 presents a comprehensive floor plan showing required VAV boxes and piping distribution throughout the building, with legend indicating ductwork routing and control valve locations. The drawings reference federal air force base standards and include detailed specifications for construction materials, dimensions, and installation requirements typical of federal building renovation projects. The plans appear designed for bid and construction purposes, with all work scoped for interior restroom and mechanical system upgrades at this military installation facility.

View the file

Other files

File Type Posted
SOW_Title_II_09022026.pdf PDF
Appendix A - Air Force Facilities Sustainability Requirements Scoresheet.xlsx XLSX spreadsheet
Appendix A - Air Force Facilities Sustainability Requirements Scoresheet.xlsx XLSX spreadsheet
Appendix G - Jones Hall B6902 DD Form 1391.pdf PDF
Appendix H - Jones Hall RLF Drawings Vol 1 of 2.pdf PDF
Appendix I - Jones Hall B6902 As-Built.pdf PDF
Appendix J - Jones Hall B6902 100 percent Specifications.pdf PDF
RFQD-TII-Jones Hall - 17 Jun 2026.pdf PDF
Appendix B - Air Force Sustainable Design and Development (SDD) Implementing Guidance.pdf PDF
Appendix F - Keesler Architectural Compatibility Guide (ACG).pdf PDF
Appendix K - Jones Hall B6902 Hazardous Material Survey.pdf PDF
Appendix Q - Jones Hall B6902 Hazardous Materials Report.pdf PDF
Appendix R - Premise Wiring Guidance.pdf PDF
Appendix P - Arnold Hall B5901 Asbestos Inspection Report.pdf PDF
Appendix C - Keesler AFB Installation Facilities Standards (IFS).pdf PDF
Appendix D - Keesler AFB Premise Wiring Guidance.pdf PDF
Appendix E - SWPPP Guidance Manual.pdf PDF
Appendix H - Jones Hall SID Binder.pdf PDF
Appendix H - Jones Hall AFB Drawings Vole 2 of 2_optimized.pdf PDF
Appendix L - Arnold Hall B5901 Drawings.pdf PDF
Appendix N - Arnold Hall B5901 Specifications.pdf PDF
Appendix O - Arnold Hall B5901 Hazardous Material Survey.pdf PDF
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1557824398E Polygon

1557824398E Text Box

AS-BUILT DRAWING MEN & WOMEN TOILET

1557824398E Polygon

1557824398E Text Box

AS-BUILT DRAWING FOR MEN & WOMEN TOILET

Arnold Hall Exist Restroom Walls-1
Arnold Hall Restroom Wall Section-1
00000654
00000659