Fort hood M&S of overhead doors, FT hood TX

Closed Pre-Solicitation Posted

Solicitation number
FTHOODFEB26P0000027100
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

PSC
Not on record
Place of performance
Fort Hood, Texas, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The U.S. Army Corps of Engineers, Engineering Support Center Huntsville is seeking a contractor to provide operation, maintenance, and service (M&S) for approximately 136 automatic doors, 3,375 overhead doors (including some hangers), and commercial doors at Fort Hood Army Installation near Killeen, Texas. The scope encompasses preventative maintenance scheduled monthly with an average of 136 tasks and on-demand corrective maintenance services with specified response requirements ranging from 15 minutes for emergency requests to next business day for routine requests. Key contract requirements include providing qualified personnel (Contract Maintenance Manager, Lead Maintenance Mechanic/Operations & Maintenance Supervisor, and a Level 1 Safety and Health Officer), maintaining 95% on-time completion rates for preventative maintenance, completing 95% of corrective maintenance within specified timeframes, and full compliance with applicable safety codes, NFPA standards, EPA regulations, and OSHA requirements. The contractor must submit comprehensive documentation including monthly progress reports, weekly corrective maintenance status reports, quality control plans, accident prevention plans, and activity hazard analyses. The sources-sought notice response deadline is March 13, 2026, at 12:00 PM Central Time, with responses to be submitted to Contract Specialist Jasmine Greene and Contracting Officer Cynthia Oxley at the Engineering Support Center Huntsville.

This procurement is not designated as a set-aside for any socio-economic category. No incumbent contractor or previous awardee information is identified in the notice. The contract is classified under NAICS 238290 (Other Building Equipment Contractors) with a size standard of $22.0 million, indicating this is open to both small and large businesses. The notice does not specify a firm contract award value; however, the market research documents reference a corrective maintenance budget of $1,375,000.00 as a reference point. The maintenance requirement covers the Main Cantonment, West and North Fort Hood, and all areas under the Fort Hood Installation's control across approximately 218,823 acres. This is a non-personal services contract structured as a firm fixed-price arrangement for preventative maintenance with separate Service Orders for corrective maintenance work. Interested vendors must provide responses to 22 detailed capability questions addressing DoD experience, facility access, regulatory compliance, emergency response capacity, staffing levels, and prior government overhead door contract experience.

Notice text

Description of the requirement: This is a sources-sought notice to determine market conditions for establishing a non-personal services contract to provide operation, maintenance and service (M&S) for approximately 136 automatic doors, 3,375 overhead doors (some hangers), and commercial doors for preventative and corrective (on demand) maintenance at the Fort Hood Army Installation, Fort Hood, Texas. Fort Hood is located near Killeen, Texas and consists of approximately 218,823 acres. The Government will not exercise any supervision or control over the contract service providers performing the services herein. Contract service providers shall be accountable solely to the Contractor who, in turn, is responsible to the Government. The Contractor shall provide required preventive maintenance (PM) and corrective maintenance (CM) services in compliance with all code; criteria; regulations; and Federal, State, and local laws. All work shall be performed at Fort Hood, Texas, which consists of the Main Cantonment, West and North Fort Hood, and all areas under the control of the Fort Hood Installation or considered Installation Real Property.

Preventive maintenance is a scheduled task; monthly average is 136. Demand maintenance is a corrective maintenance task that has a time response requirement. The selected Awardee must maintain and present a healthy, clean, neat, and professional appearance for all Commercial Doors included in this forthcoming solicitation in support of mission requirements for users, residents, and visitors.

Files

File Type Posted
PWS - FYXX B1 Project TE-4 Service Order Forms YYYYMMDD.pdf PDF
PWS - FYXX B1 Project TE-3 Monthly Progress Report Format YYYYMMDD.pdf PDF
PWS - FYXX B1 Project Appendix G Acronyms and Definitions YYYYMMDD.pdf PDF
DRAFT_PWS- FY25 B1 Ft Cavazos Doors MS TE-6 Wkly CMPM Data Templat_250523.xlsx XLSX spreadsheet
PWS - FYXX B1 Project Appendix F Applicable Codes Standards and Regulations YYYYMMDD.pdf PDF
PWS - FYXX B1 Project Appendix D Required Submittals Reports Meetings YYYYMMDD.pdf PDF
PWS - FY25 B1 Ft Cavazos Doors MS TE-4 Service Order Forms 250523.pdf PDF
PWS - FYXX B1 Fort Hood Doors Appendix C Performance Requirements Summary 250523.pdf PDF
PWS - FY25 B1 Ft Cavazos Doors MS Appendix G Acronyms and Definitions 250523.pdf PDF
PWS - FY25 B1 Ft Cavazos Doors MS Appendix A Technical Exhibits 250523.pdf PDF
PWS - FYXX B1 Fort Hood Doors MS Appendix A Technical Exhibits.pdf PDF
PWS - FYXX B1 Fort Hood Doors MS 251124.pdf PDF
PWS - FY25 B1 Ft Cavazos Doors MS Appendix H Service Order Process 250523.pdf PDF
PWS - FY25 B1 Ft Cavazos Doors MS Appendix D Required Submittals 250523.pdf PDF
PWS - FYXX B1 Project Appendix E RMS YYYYMMDD.pdf PDF
PWS - FY25 B1 Ft Cavazos Doors MS Appendix C Performance Requirements Summary 250523.pdf PDF
DRAFT_PWS - FY25 B1 Ft Cavazos Doors MS TE-2 Equipment List_250523.xlsx XLSX spreadsheet
PWS - FY25 B1 Ft Cavazos Doors MS Appendix B.2 APP Worksheet Eng_Form_6293_Aug 2024.pdf PDF
FT Hood Overhead Doors_Sources Sought_MKT RSRCH.pdf PDF
PWS - FY25 B1 Ft Cavazos Doors MS TE-3 Monthly Progress Report Format 250523.pdf PDF
PWS - FYXX B1 Project Appendix H Service Order Process YYYYMMDD.pdf PDF
PWS - FY25 B1 Ft Cavazos Doors MS Appendix E RMS 20250523.pdf PDF
DRAFT_PWS - FY25 B1 Ft Cavazos Doors MS TE-5 Engineer Form 3394 08012021.pdf PDF
DRAFT_PWS - FY25 B1 Ft Cavazos Doors Appendix B.2 APP Worksheet Eng_Form_6293_Aug 2024.pdf PDF
PWS - FY25 B1 Ft Cavazos Doors MS Appendix B.1 SSHO_Designation_Eng_Form_6282_2023Aug28.pdf PDF
Show all 25

Similar open opportunities

Opportunity Agency Set-aside Responses due
Design-Build Maintenance and Repair Army Reserve (MRAR) of Equipment Concentration Site (ECS), B-56767, at North Fort Hood, TX Bldg. 56767 Equipment Concentration Site (ECS) #6428th St. and Park Ave.North Fort Hood, TX Gatesville, Texas 76528, United States · NAICS 236220 ENDIST Louisville Total Small Business
Unaccompanied Enlisted Personnel Housing (UEPH) Barracks# 103 Fort Hood, Texas, United States · NAICS 236220 ENDIST Fort Worth No set-aside
ID- kooskia NFH-overhead door replace NAICS 238290 — Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors