This is a Work Package specification for pilot house navigation and systems rehabilitation as part of a larger landing craft restoration project. Work Package B details the comprehensive refurbishment and modernization of a 42-foot Munson Landing Craft's pilot house for the National Park Service at Lake Roosevelt National Recreation Area. The scope encompasses inspection, testing, and replacement of engine gauges (tachometers, oil pressure, coolant temperature, voltmeters, fuel level indicators), marine-rated electrical switches, and indicator lights for engine alarms and navigation status. The operator console requires removal of deteriorated panels and replacement with marine-grade composite or aluminum materials, including new fasteners, gaskets, and weatherproofing seals around windows, doorframes, antennas, and electrical penetrations.

Navigation electronics installation is a primary requirement, including supply and installation of one Garmin GPS chartplotter with integrated depth sounder/fishfinder capability, proper transducer mounting, routing through watertight glands, and loading of U.S. inland and coastal waterway charts specific to Lake Roosevelt. The work package also mandates removal and replacement of degraded insulation with flame-retardant, moisture-resistant marine insulation panels in pilot house and engine bay bulkhead areas, plus installation of USCG-approved portable fire extinguishers, navigation lights, flares, life rings, and audible signaling devices. All components must be fully functional and labeled upon completion, with acceptance criteria including successful Garmin GPS operability, structural soundness of the operator console, proper insulation installation meeting marine safety standards, and USCG-compliant safety equipment placement. A minimum 12-month warranty on installed components and workmanship is required, with manufacturer warranties applying to Garmin electronics and safety equipment.

View the file

Other files

File Type Posted
Sol_140P8326Q0057_Amd_0002.pdf PDF
IMG_5450_0001.jpeg JPEG file
IMG_5452_0001.jpeg JPEG file
IMG_1630_0001.jpeg JPEG file
Sol_140P8326Q0057_Amd_0001.pdf PDF
IMG_5449_0001.jpeg JPEG file
IMG_1629_0001.jpeg JPEG file
IMG_5451_0001.jpeg JPEG file
Munson_Signin_Sheet_0001.pdf PDF
QA_0001.docx DOCX document
IMG_5453_0001.jpeg JPEG file
IMG_1631_0001.jpeg JPEG file
IMG_1632_0001.jpeg JPEG file
Sol_140P8326Q0057.pdf PDF
IMG_0659.jpeg JPEG file
B08_Attachment_02_Price_Schedule_and_Forms_to_Submit_with_Quote.docx DOCX document
IMG_0792.jpeg JPEG file
IMG_0769.jpeg JPEG file
Work_Package_A.docx DOCX document
Work_Package_C.docx DOCX document
IMG_0621.jpeg JPEG file
IMG_0790.jpeg JPEG file
IMG_0795.jpeg JPEG file
IMG_0674.jpeg JPEG file
Relevant_Project_Experience_Questionnaire.docx DOCX document
Key_Personnel_and_Key_Trades.docx DOCX document
SCOPE_OF_WORK_MASTER.docx DOCX document
Materials.docx DOCX document
Work_Package_D.docx DOCX document
Work_Package_E.docx DOCX document
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Work Package B – Pilot House Navigation & Systems B.1 Purpose To inspect, refurbish, and upgrade the pilot house navigation and operator systems to ensure full operational capability, safety, and compliance with current marine standards. This includes replacement of outdated components, installation of modern navigation electronics, and integration of USCG-compliant safety equipment.

B.2 Scope of Work B.2.1 Gauges, Meters, Switches, and Lighting

· Evaluate and test all existing engine gauges including:

· Tachometers, oil pressure, coolant temperature, voltmeters, and fuel level indicators.

· Replace or refurbish any non-functional or outdated gauges with marine-rated, ignition-protected units.

· Replace pilot house electrical switches with marine-rated toggle or rocker switches as necessary.

· Install new marine-grade indicator lights for:

· Engine alarms, navigation status, and system alerts.

· Test all circuits, fuses, and breakers; repair or replace any deficiencies.

B.2.2 Operator Console Refurbishment

· Remove deteriorated console panels and replace with marine-grade composite or aluminum panels.

· Inspect and replace fasteners, gaskets, and weatherproofing seals around:

· Windows, doorframes, searchlight mounts, antennas, and electrical penetrations.

B.2.3 Navigation Electronics

· Supply and install one (1) Garmin (brand name or equal) GPS chartplotter with integrated depth sounder/fishfinder capability.

· Mount transducer per manufacturer guidelines and route cabling through watertight glands.

· Load the latest U.S. inland and coastal waterway electronic charts specific to Lake Roosevelt.

· Configure system for vessel-specific parameters including:

· Length, draft, speed alarms, and waypoint routing.

· Provide onboard orientation and operational training for NPS personnel.

B.2.4 Marine-Grade Insulation

· Remove degraded insulation from the pilot house and engine bay bulkhead areas.

· Install new thermal and acoustic marine insulation panels that are:

· Flame-retardant, moisture-resistant, and securely adhered.

· Ensure insulation is sealed at all edges and penetrations to prevent moisture ingress.

B.2.5 Safety Equipment

· Install USCG-approved portable fire extinguishers appropriate for vessel class and compartment size.

· Verify accessibility and secure mounting per USCG regulations.

· Supply and install any additional USCG-required safety gear identified during inspection, including:

· Navigation lights, flares, life rings, and audible signaling devices.

B.3 Acceptance Criteria

· All gauges, meters, switches, and lights are fully functional and labeled.

· Garmin GPS and depth finder are operational with charts installed and configured.

· Operator console is structurally sound, weatherproofed, and ergonomically arranged.

· Insulation is properly installed and meets marine safety standards.

· Fire extinguishers and safety equipment are installed in accordance with USCG requirements.

· Owner sign-off following successful demonstration and training.

B.4 Warranty

· Minimum 12-month warranty on all installed components and workmanship.

· Manufacturer warranties apply to Garmin electronics and safety equipment.