This document is a set of technical specifications for a federal contract to construct a KC-46 Two-Bay Maintenance/Fuel Cell Hangar at March Air Reserve Base (ARB) in California. The project has an estimated construction cost between $100,000,000 and $250,000,000. The government is seeking a full and open competition, with a HUBZone 10% price evaluation preference. The solicitation utilizes a best value/tradeoff acquisition approach. Key details include:
- The project includes construction of a new maintenance/fuel cell hangar facility at March ARB.
- The technical specifications are divided into multiple volumes covering various disciplines (architectural, structural, mechanical, electrical, etc.).
- The work involves demolition, site work, concrete, masonry, metals, carpentry, thermal and moisture protection, doors/windows, finishes, specialties, conveying equipment, fire suppression, plumbing, HVAC, electrical, and more.
- Offerors must submit proposals in response to the solicitation, which includes instructions for submitting technical and price proposals.
- The contract will be awarded to the offeror providing the best value to the government based on the stated evaluation criteria.
View the file
Other files
Show all 29
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Solicitation For Building 1244 Addition/Alteration for FuT- Pallet Storage, March Air Reserve Base, CA
P2: 504634
Design-Bid-Build
Specifications - Vol. 2 of 3 (DIV 12 - 31) Certified Final Design
04 September 2024
W912QR24R0034
ARIMS: 200A Disposition: Maintain for 15yrs after construction.
W912QR24R0034_B1244_Specs_Vol2-0000
ADDITION/ALTERATION OF BLDG 1244 FOR FUT-
PALLET STORAGE
March Air Reserve Base, CA
W912QR-21-D-0070, T.O.: W912QR22F0327
April 2024
Burns & McDonnell 9400 Ward Parkway
Kansas City, MO 64114
CERTIFICATION PAGE
CIVIL STRUCTURAL ARCHITECTURAL
FIRE PROTECTION MECHANICAL ELECTRICAL
04/08/2024
April 9, 2024
R
E
No. S5406
R
S
T
A
T
E
E G
I S
T
E
O
F
CA
L
I
F
N
I
O
R
R
A
N
G
I
N
E E
R
E
D
P
S
O
F
E S
I
O
N
A
L
K
I
R
K
J
. S
N
E
L
L
S
T
R
U
CT
U
R
A
L
EXP. 9/30/2024
04/08/2024
04/08/2024
P2# 504634 Addition/Alteration of B1244 March Air Base, CA
PROJECT TABLE OF CONTENTS
DIVISION 02 - EXISTING CONDITIONS
02 41 00 08/22 DEMOLITION AND DECONSTRUCTION
02 81 00 TRANSPORTATION AND DISPOSAL OF
HAZARDOUS MATERIALS
02 82 00 ASBESTOS REMEDIATION
02 83 00 LEAD REMEDIATION
02 84 16 HANDLING OF LIGHTING BALLASTS AND
LAMPS CONTAINING PCBs AND MERCURY
02 84 33 05/20
REMOVAL AND DISPOSAL OF
POLYCHLORINATED BIPHENYLS (PCBs)
DIVISION 03 - CONCRETE
03 30 00 02/19, CHG 4: 08/22 CAST-IN-PLACE CONCRETE
03 33 00 11/09 CAST-IN-PLACE ARCHITECTURAL CONCRETE
DIVISION 04 - MASONRY
04 20 00 11/15, CHG 2: 05/19 UNIT MASONRY
DIVISION 05 - METALS
05 05 20 05/22 POST-INSTALLED CONCRETE AND MASONRY
ANCHORS
05 05 23.16 08/18 STRUCTURAL WELDING
05 12 00 08/18, CHG 2: 05/21 STRUCTURAL STEEL
05 30 00 05/15, CHG 2: 08/18 STEEL DECKS
05 40 00 05/15, CHG 1: 08/18 COLD-FORMED METAL FRAMING
05 50 13 05/17, CHG 1: 08/18 MISCELLANEOUS METAL FABRICATIONS SS
COUNTERTOPS
05 51 00 08/23 METAL STAIRS
05 51 33 02/16, CHG 2: 02/18 METAL LADDERS
05 52 00 02/18, CHG 1: 02/20 METAL RAILINGS
DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES
06 10 00 08/16, CHG 2: 11/18 ROUGH CARPENTRY
06 41 16.00 10 08/10, CHG 1: 11/18 PLASTIC-LAMINATE-CLAD ARCHITECTURAL
CABINETS
06 61 16 08/20 SOLID SURFACING FABRICATIONS
DIVISION 07 - THERMAL AND MOISTURE PROTECTION
07 05 23 08/19 PRESSURE TESTING AN AIR BARRIER SYSTEM
FOR AIR TIGHTNESS
07 11 13 08/11, CHG 1: 05/17 BITUMINOUS DAMPPROOFING
07 21 13 02/16, CHG 2: 08/20 BOARD AND BLOCK INSULATION
07 21 16 11/11, CHG 4: 08/18 MINERAL FIBER BLANKET INSULATION
07 22 00 02/16, CHG 3: 11/18 ROOF AND DECK INSULATION
07 27 10.00 10 08/19, CHG 1: 02/20 BUILDING AIR BARRIER SYSTEM
07 27 19.01 05/17, CHG 2: 08/20 SELF-ADHERING AIR BARRIERS
DOCUMENT PROJECT Page 1 Certified Final Status
HAZARDOUS MATERIALS SURVEY
W912QR24R0034_B1244_Specs_Vol2-0000 vhquintero Snapshot vhquintero Snapshot
07 27 26 05/17, CHG 2: 08/20 FLUID-APPLIED MEMBRANE AIR BARRIERS
07 27 36 05/17, CHG 2: 08/20 SPRAY FOAM AIR BARRIERS
07 42 13 05/11, CHG 2: 02/18 METAL WALL PANELS
07 42 63 05/11, CHG 4: 08/20 FABRICATED WALL PANEL ASSEMBLIES
07 54 19 02/13, CHG 3: 02/21 POLYVINYL-CHLORIDE ROOFING
07 60 00 05/17, CHG 2: 11/18 FLASHING AND SHEET METAL
07 61 14.00 20 08/16, CHG 1: 08/18 STEEL STANDING SEAM ROOFING
07 84 00 05/10, CHG 1: 08/13 FIRESTOPPING
07 92 00 08/16, CHG 3: 11/18 JOINT SEALANTS
DIVISION 08 - OPENINGS
08 11 13 08/20 STEEL DOORS AND FRAMES
08 31 00 05/17, CHG 1: 08/18 ACCESS DOORS AND PANELS
08 33 23 08/20, CHG 1: 02/22 OVERHEAD COILING DOORS
08 51 13 05/19 ALUMINUM WINDOWS
08 71 00 02/16, CHG 4: 02/22 DOOR HARDWARE
08 81 00 05/19 GLAZING
08 91 00 08/20 METAL WALL AND DOOR LOUVERS
DIVISION 09 - FINISHES
09 06 00 08/22 SCHEDULES FOR FINISHES
09 22 00 02/10, CHG 2: 08/18 SUPPORTS FOR PLASTER AND GYPSUM BOARD
09 29 00 08/16, CHG 4: 02/20 GYPSUM BOARD
09 30 10 08/20 CERAMIC, QUARRY, AND GLASS TILING
09 51 00 08/20 ACOUSTICAL CEILINGS
09 65 00 08/10, CHG 3: 08/18 RESILIENT FLOORING
09 68 00 11/17, CHG 2: 08/20 CARPETING
09 90 00 02/21 PAINTS AND COATINGS
09 97 13.27 02/21, CHG 1: 08/22 HIGH PERFORMANCE COATING FOR STEEL
STRUCTURES
DIVISION 10 - SPECIALTIES
10 14 00.10 08/17, CHG 1: 11/18 EXTERIOR SIGNAGE
10 14 00.20 08/20 INTERIOR SIGNAGE
10 21 13 08/20 TOILET COMPARTMENTS
10 26 00 08/20 WALL AND DOOR PROTECTION
10 28 13 08/20 TOILET ACCESSORIES
10 44 16 11/19 FIRE EXTINGUISHERS
10 56 13 04/06 STEEL SHELVING
10 81 13 03/10 BIRD CONTROL DEVICES (BID OPTION)
DIVISION 12 - FURNISHINGS
12 24 13 08/20 ROLLER WINDOW SHADES
12 50 00.13 10 08/17, CHG 1: 11/18 FURNITURE AND FURNITURE INSTALLATION
12 59 00 08/17, CHG 1: 08/18 SYSTEMS FURNITURE
DIVISION 21 - FIRE SUPPRESSION
21 13 13 08/20 WET PIPE SPRINKLER SYSTEMS, FIRE
PROTECTION
21 30 00 04/08, CHG 1: 08/13 FIRE PUMPS
DIVISION 22 - PLUMBING
22 00 00 11/15, CHG 4: 05/21 PLUMBING, GENERAL PURPOSE
DOCUMENT PROJECT Page 2 Certified Final Status
DIVISION 23 - HEATING, VENTILATING, AND AIR CONDITIONING (HVAC)
23 03 00.00 20 08/10, CHG 3: 08/18 BASIC MECHANICAL MATERIALS AND METHODS
23 05 48.19 05/18, CHG 2: 08/20 SEISMIC BRACING, SUPPORTS, ANCHORAGE,
AND VIBRATION ISOLATION FOR MECHANICAL
SYSTEMS
23 05 93.00 06 08/16 TESTING, ADJUSTING, AND BALANCING
(TAB) OF HVAC
23 07 00 02/13, CHG 7: 05/20 THERMAL INSULATION FOR MECHANICAL
SYSTEMS
23 09 00 02/19, CHG 3: 05/21 INSTRUMENTATION AND CONTROL FOR HVAC
23 09 13 11/15, CHG 2: 05/21 INSTRUMENTATION AND CONTROL DEVICES
FOR HVAC
23 09 23.02 02/19, CHG 1: 02/20 BACNET DIRECT DIGITAL CONTROL FOR HVAC
AND OTHER BUILDING CONTROL SYSTEMS
23 30 00 05/20, CHG 1: 02/22 HVAC AIR DISTRIBUTION
23 35 16.17 10 05/20 MECHANICAL ENGINE EXHAUST SYSTEMS
23 81 00 05/18, CHG 1: 02/21 DECENTRALIZED UNITARY HVAC EQUIPMENT
DIVISION 25 - INTEGRATED AUTOMATION
25 05 11.01 05/21 CYBERSECURITY FOR FACILITY-RELATED
CONTROL SYSTEMS - HVAC AND AMI
25 05 11.02 05/21 CYBERSECURITY FOR FACILITY-RELATED
CONTROL SYSTEMS - FIRE PROTECTION
DIVISION 26 - ELECTRICAL
26 05 26.00 40 08/19 GROUNDING AND BONDING FOR ELECTRICAL
SYSTEMS
26 05 48.00 10 10/07 SEISMIC PROTECTION FOR ELECTRICAL
EQUIPMENT
26 05 73 08/23 POWER SYSTEM STUDIES
26 20 00 08/19, CHG 3: 11/21 INTERIOR DISTRIBUTION SYSTEM
26 29 23 02/20, CHG 1: 05/21 ADJUSTABLE SPEED DRIVE (ASD) SYSTEMS
UNDER 600 VOLTS
26 41 00 11/13 LIGHTNING PROTECTION SYSTEM
26 51 00 05/20, CHG 2: 11/21 INTERIOR LIGHTING
26 56 00 08/21 EXTERIOR LIGHTING
DIVISION 27 - COMMUNICATIONS
27 10 00 08/11 BUILDING TELECOMMUNICATIONS CABLING
SYSTEM
DIVISION 28 - ELECTRONIC SAFETY AND SECURITY
28 31 76 08/20 INTERIOR FIRE ALARM AND MASS
NOTIFICATION SYSTEM, ADDRESSABLE
DIVISION 31 - EARTHWORK
31 00 00.00 06 07/18 EARTHWORK
31 05 22.00 06 07/16 GEOTEXTILES USED AS FILTERS
31 32 23.00 06 07/16 LOW MOBILITY GROUTING AND GROUT PILES
DIVISION 32 - EXTERIOR IMPROVEMENTS
DOCUMENT PROJECT Page 3
32 01 19.61 11/19 SEALING OF JOINTS IN RIGID PAVEMENT
32 05 33 08/17 LANDSCAPE ESTABLISHMENT
32 11 23 05/22 GRADED CRUSHED AGGREGATE BASE COURSE
32 11 33.13 05/20 PORTLAND CEMENT-STABILIZED BASE COURSES
32 12 13 05/17 BITUMINOUS TACK AND PRIME COATS
32 12 16.16 11/20 ROAD-MIX ASPHALT PAVING
32 13 13.06 05/20 PORTLAND CEMENT CONCRETE PAVEMENT FOR
ROADS AND SITE FACILITIES
32 13 73.00 06 07/16 COMPRESSION JOINT SEALS FOR CONCRETE
PAVEMENTS
32 16 19 05/18 CONCRETE CURBS, GUTTERS AND SIDEWALKS
32 17 23 08/16, CHG 5: 11/18 PAVEMENT MARKINGS
32 31 13 11/21 CHAIN LINK FENCES AND GATES
32 92 19 08/17, CHG 1: 08/21 SEEDING
DIVISION 33 - UTILITIES
33 30 00 05/18 SANITARY SEWERAGE
33 40 00 11/21 STORMWATER UTILITIES
33 82 00 04/06 TELECOMMUNICATIONS OUTSIDE PLANT (OSP)
-- End of Project Table of Contents --
DOCUMENT PROJECT Page 4
SECTION 12 24 13
ROLLER WINDOW SHADES
08/20
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by basic designation only.
AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)
ANSI/WCMA A100.1 (2018) American National Standard for Safety of Window Covering Products
ASTM INTERNATIONAL (ASTM)
ASTM G21 (2015; R 2021; E 2021) Standard Practice for Determining Resistance of Synthetic Polymeric Materials to Fungi
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 701 (2019) Standard Methods of Fire Tests for Flame Propagation of Textiles and Films
SCIENTIFIC CERTIFICATION SYSTEMS (SCS)
SCS SCS Global Services (SCS) Indoor Advantage
UNDERWRITERS LABORATORIES (UL)
UL 2818 (2013) GREENGUARD Certification Program For Chemical Emissions For Building Materials, Finishes And Furnishings
1.2 SUBMITTALS
Government approval is required for submittals with a "G" or "S" classification. Submittals not having a "G" or "S" classification are for information only. When used, a code following the "G" classification identifies the office that will review the submittal for the Govern ment.
Submit the following in accordance with Section 01 33 00 SUBMITTAL
PROCEDURES
SD-02 Shop Drawings
Detailed Drawings; G AE
Location Schedule; G AE
SD-03 Product Data
Window Shades; G AE
SECTION 12 24 13 Page 1
Recycled Content for various fiber components; S
SD-04 Samples
Window Shades; G AE
SD-06 Test Reports
Flammability Requirements; G
SD-07 Certificates
Indoor Air Quality for roller window shades; S
Qualifications
SD-10 Operation and Maintenance Data
Window Shades, Data Package 1; G
SD-11 Closeout Submittals
Submit Data Package 1 for roller window shades, and Data Package 2 for electrical operators, in accordance with Section 00 80 00.00 06
SPECIAL PROVISIONS.
1.3 CERTIFICATES
1.3.1 Indoor Air Quality Certifications
1.3.1.1 Roller Window Shades
Provide products certified to meet indoor air quality requirements by UL 2818 (Greenguard) Gold, SCS Global Services Indoor Advantage Gold or provide validation by other third-party program that products meet the requirements of this paragraph. Provide current product certification documentation from certification body.
1.4 QUALITY ASSURANCE
1.4.1 Qualifications
1.4.1.1 Installer's Qualifications
Installer trained and certified by the manufacturer with a minimum of ten years of experience in installing products comparable to those spec ified in this section.
1.4.2 Flammability Requirements
Passes in accordance with NFPA 701 small and large-scale vertical burn.
Materials tested are identical to products proposed for use.
1.4.3 Anti-Microbial Requirements
'No Growth' per ASTM G21 results for fungi ATCC9642, ATCC 9644, ATCC9645.
SECTION 12 24 13 Page 2
1.5 DELIVERY, STORAGE, AND HANDLING
Deliver components to the job site in the manufacturer's original packaging with the brand or company name, item identification, and project reference clearly marked. Store components in a dry location that is adequately ventilated and free from dust, water, or other contaminants and has easy access for inspection and handling. Store materials flat in a clean dry area with temperature maintained above 50 degrees F. Do not open containers until needed for installation unless verification inspection is required. Handle and store shades in accordance with manufacturer's recommendations.
1.6 WARRANTY
Provide manufacturer's warranty to repair or replace defective materials and workmanship for a period of 10 years from date of final acceptance of the work.
PART 2 PRODUCTS
2.1 WINDOW SHADES
Submit drawings showing plans, elevations, sections, product details, installation details, operational clearances, wiring diagrams and relationship to work. Submit a location schedule showing location, size and quantity of shades. Include the use of same room designations as indicated on the drawings.
Provide product data composed of catalog cuts, brochures, and operating and maintenance instructions on each product to be used. Include styles, profiles and features.
Furnish samples of each type and color of roller shade fabric and roller shade channel. Provide shade material minimum 6 by 6 inches in size.
Mark face of material to indicate interior faces.
Mock up: Install shade in area designated by Contracting Officer. Do not proceed with remaining work until the Contracting Officer approves workmanship and operation. Rework mock up as required to produce acceptable work. The approved shade can be used in the installation.
Submit fire resistance data, flame spread and smoke contribution da ta.
Provide roller tube that operates smoothly and of sufficient diamet er and thickness to prevent excessive deflection. Provide brackets that are appropriate for inside mount. Provide shade cloth meeting the perf ormance described in NFPA 701 , small scale test. Treat steel features for corrosion resistance.
Provide Various Fiber Components with a minimum of 60 percent recycled content. Provide data identifying percentage of recycled content f or various fiber components.
Provide certification of indoor air quality for roller window shades.
2.1.1 Manufacturer's Qualifications
Obtain motor-controlled roller shades through one source from a sin gle manufacturer with a minimum of twenty years of experience and minim um of
SECTION 12 24 13 Page 3 three projects of similar scope and size in manufacturing products comparable to those specified in this section. Furnish manual and motorized shades produced by the same manufacturer to provide matching appearance.
2.1.2 Manually Operated Shades with Single Rollers
2.1.2.1 Chain-and-Clutch Operating Mechanisms
Provide continuous-loop bead chain and clutch that stops shade movement when bead chain is released; shade to be permanently adjusted and lubricated.
2.1.2.2 Bead Chains
Provide bead chain from #10 stainless steel rated to 90 lb minimum breaking strength with pull chain tensioning device complying with
ANSI/WCMA A100.1 .
a. Loop Length: Full length of roller shade.
b. Limit Stops: Allows shade to stop when chain is released. Provide limit stops to prevent shade from being raised or lowered too far.
c. Chain-Retainer Type: Chain tensioner, jamb mounted.
2.1.2.3 Rollers
Provide corrosion-resistant steel or extruded-aluminum tubes of diameters and wall thicknesses required to accommodate operating mechanisms and weights and widths of shade bands indicated without deflection. Provide with permanently lubricated drive-end assemblies and idle-end assemblies designed to facilitate removal of shade cloth for service.
a. Roller Drive-End Location: Right side of interior face of shade.
b. Direction of Shade cloth Roll: Regular, from back (exterior face) of roller.
c. Shade cloth-to-Roller Attachment: Manufacturer's standard method.
Adhesive attachment is not acceptable.
2.1.2.4 Mounting Hardware
Provide corrosion resistant brackets or endcaps compatible with roller assembly, operating mechanism, installation accessories, and mounti ng location and conditions indicated. Provide hardware that allows for field adjustment or removal of shade roller tube and other operable hardware component without removal of brackets and end or center supports.
2.1.2.5 Shade Cloth
a. Shade Material: Light-filtering fabric: Openness - reference Finish Legend in drawings, 3 percent.
b. Shade Cloth Bottom (Hem) Bar: Steel or extruded aluminum. Pro vide shade bar enclosed in sealed pocket of shade band material.
SECTION 12 24 13 Page 4
2.1.2.6 Installation Accessories
a. Front Fascia: L-shaped aluminum extrusion to conceal shade roller and hardware that snaps onto end caps without requiring exposed fasteners of any kind. Fascia can be mounted continuously across two or more shade bands. Provide manufacturers standard height fascia as required to conceal roller and shade band assembly when shade is fully open.
b. Endcaps: Extruded aluminum with universal design suitable for mounting to window mullions. Provide size compatible with roller size. Provide end cap covers matching fascia/headbox finish.
2.2 COLOR
Provide color, pattern and texture for metal trim and shade fabric as specified in Section 09 06 00 SCHEDULES FOR FINISHES.
PART 3 EXECUTION
3.1 FIELD MEASUREMENTS
After becoming familiar with details of the work, verify all dimensions in the field, and advise the Contracting Officer of any discrepancy before performing the work.
3.2 ROLLER WINDOW SHADE PLACEMENT SCHEDULE
All exterior windows to receive RS-1.
3.3 INSTALLATION
Do not install building construction materials that show visual evidence of biological growth.
Provide roller window shades, complete with necessary brackets, fittings, and hardware as indicated.
Perform installation in accordance with the approved detailed drawings and manufacturer's installation instructions. Install units level, plumb, secure, and at proper height and location relative to window units.
Provide and install supplementary or miscellaneous items in total, including clips, brackets, or anchorages incidental to or necessary for a sound, secure, and complete installation. Do not start installatio n until completion of room painting and finishing operations.
3.4 CLEAN-UP
Upon completion of the installation, clean window treatments and exposed components as recommended by manufacturer. Adjust window treatment for form and appearance and proper operating condition. Repair or replace damaged units as directed by the Contracting Officer. Isolate meta l parts from direct contact with concrete, mortar, or dissimilar metals. E nsure shades installed in recessed pockets can be removed without disturbing the pocket. The entire shade, when retracted, is contained inside the pocket. For shades installed outside the jambs and mullions, overl ap each jamb and mullion 0.75 inch or more when the jamb and mullion sizes permit. Include all hardware, brackets, anchors, fasteners, and accessories necessary for a complete, finished installation.
SECTION 12 24 13 Page 5
-- End of Section --
SECTION 12 24 13 Page 6
SECTION 12 50 00.13 10
FURNITURE AND FURNITURE INSTALLATION
08/17, CHG 1: 11/18
PART 1 GENERAL
Purchase and install furniture as identified within this specification.
This specification section includes a Furniture, Fixtures and Equipment (FF&E) Package attachment.
The requirements of this specification also apply to systems furniture unless otherwise specified in Section 12 59 00 SYSTEMS FURNITURE.
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING
ENGINEERS (ASHRAE)
ASHRAE 90.1 - IP (2013) Energy Standard for Buildings Except Low-Rise Residential Buildings
ASTM INTERNATIONAL (ASTM)
ASTM D4157 (2013; R 2017) Standard Test Method for Abrasion Resistance of Textile Fabrics (Oscillatory Cylinder Method)
ASTM E1537 (2016) Standard Test Method for Fire Testing of Upholstered Furniture
BIFMA INTERNATIONAL (BIFMA)
ANSI/BIFMA X5.1 (2017) American National Standards For Office Furnishings - General Purpose Office Chairs
ANSI/BIFMA X5.5 (2014) American National Standards For Office Furnishings -Desk Products
ANSI/BIFMA X5.6 (2016) American National Standards For Office Furnishings -Panel Systems
ANSI/BIFMA X5.9 (2012) American National Standards For Office Furnishings - Storage Units
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 101 (2021; TIA 22-1; ERTA 1 2022) Life Safety Code
SECTION 12 50 00.13 10 Page 1
STATE OF CALIFORNIA DEPARTMENT OF CONSUMER AFFAIRS, BUREAU OF
ELECTRICAL AND APPLIANCE REPAIR, HOME FURNISHINGS AND THERMAL
INSULATION (BEARHFTI)
TB 133 (1991) Flammability Test Procedure for Seating Furniture in Public Occupancies
TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA)
TIA-568.2 (2018d) Balanced Twisted-Pair Telecommunications Cabling and Components Standards
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines
1.2 SUBMITTALS
Government approval is required for submittals with a "G" or "S" classification. Submittals not having a "G" or "S" classification are for information only. When used, a code following the "G" classification identifies the office that will review the submittal for the Government.
Submit the following in accordance with Section 01 33 00 SUBMITTAL
PROCEDURES:
SD-01 Preconstruction Submittals
Storage Location; G AFRC
SD-02 Shop Drawings
Installation Drawings; G AFRC
Grommet, Power and Communication Units, and Wire Management Locations; G AFRC
SD-03 Product Data
Product Data; G AFRC
Product Style Options; G AFRC
SD-04 Samples
Fabric and Finishes; G AFRC
SD-07 Certificates
Authorized Dealer; G AFRC
Certified Furniture Installers; G AFRC
Licensed Electrician; G AFRC
Certified Telecommunications Installer; G AFRC
SECTION 12 50 00.13 10 Page 2
Manufacturer's Certification; G AFRC
Warranty; G AFRC
SD-10 Operation and Maintenance Data
Furniture, Data Package 1; G AFRC
SD-11 Closeout Submittals
Energy Efficient Equipment; S AFRC
Reduced VOC's for Furniture; S AFRC
Recycled Content of Furniture; S AFRC
Bio-Based Content of Furniture; S AFRC
1.3 SERVICES
Provide services to include furniture purchase, field measuring, installation drawings, shipping and delivery coordination, receiving, inspection, submitting and processing freight and warranty claims, unpacking, storing, assembly, installation and other related activities or tasks for a complete and functional installation. Reference Section 01 45 04.10 06 CONTRACTOR QUALITY CONTROL for inspection requirements.
The Contracting Officer must be allowed to participate in inspections.
Develop project timelines and establish shipping, receiving and installation dates that coordinate with the building construction schedule.
Hold at a minimum weekly team meetings to brief the project team, include the Contracting Officer. Notify the Contracting Officer immediately of any scheduling problems, discontinued furniture items including fabrics and finishes, or other conditions which may cause delays, and recommend available substitutes, solutions, and provide updated timeline to coordinate with building construction schedule.
Substitutes and solutions must comply with the specification and be approved by the Contracting Officer.
1.4 FURNITURE PURCHASE
Purchase furniture, including checking accuracy of all acknowledgem ents and schedules from manufacturers and making necessary corrections t o ensure that the manufacturer has a correct understanding of the ord er and requirement. Purchase furniture from the open market. The furniture provided needs to be available on the GSA Schedules to assist the U ser with future purchases. Complete the furniture purchase by obtaining a minimum of (3) separate proposals. Furniture is subject to FAR clause 52.236-5 Materials and Workmanship. If necessary to meet project timeline requirements, furniture may be purchased using manufacturers quick-ship programs or by coordinating factory times.
1.5 ALTERNATE DESIGN
When a manufacturer's product is unable to provide desk and worksta tion configurations and filing/storage that conform exactly to the furni ture layouts shown in the contract drawings and specifications, alternat e designs may be submitted for consideration by the Contracting Offic er.
Alternate designs must meet or exceed the following criteria. Alte rnate
SECTION 12 50 00.13 10 Page 3 designs that are submitted but do not meet these criteria will be rejected.
1.5.1 Desk and Workstation Size and Configuration
The alternate design must provide desks and workstations of the same basic size and configuration shown, with only the sizes of the individual components within the desk and workstation changed to meet the standard product of the manufacturer.
1.5.2 Filing and Storage Size and Configuration
The alternate design must provide filing and storage of the same basic size and configuration shown, with only the size changed to meet the standard product of the manufacturer. The storage capacity must not be reduced.
1.5.3 Furniture Requirements
The furniture provided must comply with the drawings, specifications, and the requirements identified in the FF&E Package Attachment.
1.5.4 Layout
The storage capacity, number of desks and workstations, number of persons accommodated, width of aisles, and functionality must be maintained.
Layout must comply with NFPA 101 and 36 CFR 1191 .
1.6 AUTHORIZED DEALER, CERTIFIED FURNITURE INSTALLERS, LICENSED ELECTRICIAN
AND CERTIFIED TELECOMMUNICATIONS INSTALLER
When required by the furniture manufacturer, furniture must be installed by an authorized dealer and a certified furniture installation crew must be used on the project. All furniture requiring hardwiring must be completed by a licensed electrician. Communications installers must be Building Industry Consulting Services International (BICSI) Registered Cabling Installers, Technician Level or have a minimum of 3 years experience in the installation of the specified cables and components.
All installers, furniture, electrical and communications, must be on-site if questions arise. Submit copies of authorized dealer, furniture installation crew, licensed electrician and certified telecommunications installer certifications.
1.7 DELIVERY, STORAGE AND HANDLING
1.7.1 Delivery
Deliver furniture to the job site in manufacturer's original packaging or blanket wrapping. Original packaging must be marked with the manufacturer name, item identification, and project reference clearly marked.
1.7.2 Furniture Inspection
Inspect furniture and provide notification of damage within the time frame required by the shipping company while carrier is still on-site. Complete claims for concealed damage within the time frame required by the s hipping company and furniture manufacturer. A claim file must be maintaine d that documents each claim. Forward copies of claims to the Contracting Officer on a daily basis.
SECTION 12 50 00.13 10 Page 4
1.7.3 Storage
Storage space is not available on-site and furniture must be stored at an off site location. Provide any storage space required for furniture and transport stored furniture to the project site for installation. Storage location must be approved by the Contracting Officer at the time of the furniture order. If storage is required, furniture must be stored in a dry location that is adequately ventilated and free from dirt and dust, water, and other contaminants, in a manner that permits easy access for inspection and handling, and in an environment in accordance with furniture manufacturers instructions.
1.7.4 Furniture Staging Area
Coordinate location of the furniture staging area with the Contracting Officer.
1.8 WARRANTY
Provide manufacturer performance guarantees or warranties for single-shift service and include parts, labor and transportation as follows, unless otherwise noted:
a. Systems Furniture - see Section 12 59 00 SYSTEMS FURNITURE.
b. Desks and Workstations - 12 year minimum.
c. Filing and Storage - 12 year minimum.
d. Seating
(1) Seating, unless otherwise noted - 10 year minimum.
(2) 24/7 Seating (multiple shift use) - 10 year minimum.
(3) Seating Mechanisms and Pneumatic Cylinders - 10 year minimum.
(4) Lounge Seating - 10 year minimum.
(5) Stacking Chairs - 10 year minimum.
e. Tables
(1) Unless otherwise noted - 10 year minimum.
(2) Table Mechanisms - 5 year minimum.
(3) Table Ganging Device - 1 year minimum.
f. Miscellaneous
(1) Fabric - 3 year minimum.
(2) LED Task Lighting - 5 year minimum.
Provide items not listed with a 1 year minimum. When manufacturers standard performance guarantees or warranties exceed the minimum requirements identified, provide the standard performance guarantee or warranty. Submit manufacturer's warranty information for all furni ture
SECTION 12 50 00.13 10 Page 5 items.
PART 2 PRODUCTS
2.1 PRODUCT SUSTAINABILITY CRITERIA
For products in this section, where applicable and to extent allowed by performance criteria, provide and document the following:
2.1.1 Energy Efficient Equipment
Coordinate requirement for energy efficient equipment, such as appliances and lighting, and provide documentation in accordance with Section 01 33 29.00 06 SUSTAINABILITY REPORTING paragraph ENERGY EFFICIENT
EQUIPMENT.
2.1.2 Reduced VOC's for Furniture
Coordinate requirement for reduced VOC requirements for furniture and provide documentation in accordance with Section 01 33 29.00 06 SUSTAINABILITY REPORTING paragraph REDUCE VOLATILE ORGANIC COMPOUNDS.
2.1.3 Recycled Content of Furniture
Coordinate requirement for recycled content for furniture and provide documentation in accordance with Section 01 33 29.00 06 SUSTAINABILITY REPORTING paragraph RECYCLED CONTENT.
2.1.4 Bio-Based Content of Furniture
Coordinate requirement for biobased content for furniture and provide documentation in accordance with Section 01 33 29.00 06 SUSTAINABILITY REPORTING paragraph BIO-BASED PRODUCTS.
2.2 FURNITURE REQUIREMENTS
Use the FF&E Package Attachment in conjunction with the drawings and specifications for the furniture requirements. Systems furniture is specified in Section 12 59 00 SYSTEMS FURNITURE. Provide furniture from manufacturer's standard product as shown in the most current published price list or amendment. Furniture provided must be part of curren t line as indicated with no intent to discontinue within two years. Provi de furniture that is intended for commercial use not residential. sub mit product data for all furniture items, to include catalog cuts, broc hures, product information, and other necessary literature to indicate compliance with specifications. Provide product data for all items together i n a single submittal. Tag product data sheets with applicable furniture item code and name. Submit data for all product style options for selection when options are available. This applies to but is not limited to furniture items that have options such as edge details, hardware options, and grommet colors. Submit manufacturer's certification stating th at furniture meets the specifications.
2.2.1 Construction
a. Provide furniture that complies with the following testing requirements:
(1) ANSI/BIFMA
SECTION 12 50 00.13 10 Page 6
(a) Office Seating - ANSI/BIFMA X5.1 .
(b) Desk Products - ANSI/BIFMA X5.5 .
(c) Panel Systems - ANSI/BIFMA X5.6 .
(d) Storage - ANSI/BIFMA X5.9 .
(2) Flammability
(a) Upholstered furniture must comply with TB 133 or ASTM E1537.
b. Provide furniture with no rough or sharp edges or exposed connections. Clips, screws, and other construction elements must be concealed wherever possible.
c. Items such as desks, workstations and systems furniture must include all necessary components to be structurally sound and must not be attached to the wall unless specified to be wall mounted in the contract documents.
d. Desks, workstations, storage, and tables must have leveling devices to compensate for uneven floors.
e. The underside of desks, workstations, and tables must be completely and smoothly finished.
f. The backside of freestanding desks, workstations, and storage must be finished.
g. Provide chair casters and glides appropriate for the floor material they are located on, such as carpet and resilient flooring.
2.2.2 Locks and Keying
a. All drawers and doors, including but not limited to overhead storage cabinets, storage towers, supply cabinets, storage cabinets, desk and workstation pedestals, and filing cabinets must be lockable.
b. Key each desk and workstation in an office differently and key locks within each desk and workstation alike.
c. Furniture storage components in private offices must be keyed a like.
Key each private office differently.
d. Provide field changeable lock cylinders in desks and workstations with a minimum of 100 different key options. Number keys and lock cylinders for ease of replacement or clearly label locks with a key number, except for those manufacturers who have removable format locks.
e. Drawers within a pedestal must be lockable either by a central lock that controls all pedestals under one work surface or an individual keyed lock in each pedestal.
f. Central file and storage units which are grouped together but a re not a part of a workstation must be keyed alike unless otherwise specif ied.
g. Provide two keys for each workstation when components are keyed
SECTION 12 50 00.13 10 Page 7 alike. Also provide two keys for each miscellaneous item such as filing cabinets, supply cabinets, storage cabinets, and similar type furniture items.
h. Provide three copies of each master key to the Contracting Officer.
i. Inventory keys, label keys by lock number, room number and furniture item and turn over inventory and keys to the Contracting Officer.
2.2.3 Fabric and Finish
Submit samples of all furniture fabric and finishes. Samples must be actual samples, not photographic representations, size must be a minimum of 3 by 3 inches. If necessary, provide larger size samples to clearly represent pattern. Label samples with fabric or finish code, furniture item code and name, manufacturer name, and color information. Fabric samples must also be labeled with fiber content and double rub testing information.
2.2.3.1 Fabric
a. Fabric must be from manufacturer's standard line and graded-in textile manufacturer's fabrics. Do not provide COM fabrics.
b. Provide a mid grade fabric, unless otherwise noted. Example:
Manufacturer available grades 1 through 4 (even number of grades), provide grade 3; manufacturer available grades A through D (even number of grades), provide grade C; manufacturer available grades A through E (odd number of grades), provide grade C (middle grade).
c. Provide a topical or inherent soil retardant treatment where indicated.
d. Fabric for seating must comply with a minimum of 80,000 double rubs unless otherwise noted. Perform double rub testing in accordance with the ASTM D4157 Wyzenbeek Method.
e. Provide vinyl, polypropylene or similar type fabric for seating only if allowed in FF&E Package Attachment.
f. Pattern:
(1) Provide patterned upholstery fabric to help hide soiling. Patt ern is defined as follows:
(a) Solid Color: Textured, single color or pattern smaller in size than the small size pattern.
(b) Small Size Pattern: Minimum 1/2 inch.
(c) Medium Size Pattern: Minimum 2 inch.
(d) Large Size Pattern: Minimum 5 inch.
(2) Provide patterns as specified in the FF&E Package Attachment.
g. See FF&E Package Attachment for additional information.
SECTION 12 50 00.13 10 Page 8
2.2.3.2 Finishes
Provide furniture finishes as listed below unless otherwise noted:
a. Finishes must be able to be cleaned with ordinary household cleaning solutions. Wood finishes must be able to be cleaned with damp cloth as directed by the manufacturer.
b. The finish of steel surfaces must be the manufacturer's most durable finish such as factory powder coat or baked enamel.
c. Grommet colors must be compatible and coordinated with desk, workstation, and table finish colors.
d. Finishes must be neutral in color.
e. Plastic laminate worksurfaces and table tops must be neutral in color and must have a pattern to help hide soiling.
f. See FF&E Package Attachment for additional information.
2.3 FURNITURE LAYOUT
Provide furniture layout as indicated.
PART 3 EXECUTION
3.1 BUILDING EXAMINATION
Become familiar with details of the work, inspect all areas and conditions under which furniture is to be installed, and coordinate scheduling of dedicated elevators and docks. Notify the Contracting Officer in writing of any conditions detrimental to the proper and timely completion of the installation. Work will proceed only when conditions have been corrected.
3.2 BUILDING PROTECTION
Protect building surfaces to prevent soiling and damage during delivery and installation. Any soiling and damage that occurs to the building during the installation of furniture must be cleaned and repaired, or replaced to its original condition and must be approved by the Cont racting Officer.
3.3 INSTALLATION
3.3.1 Installation Drawings
Installation drawings must include furniture layout, critical dimensions and locations of electrical and communications. Reflect field verified conditions in furniture layouts. Drawings must be at 1/4 inch = 1 foot scale, unless otherwise specified. Provide typical plans and isometrics/elevations of desks and workstations at a scale of 1/2 i nch = 1 foot. When applicable, provide desk and workstation electrical and communications locations. When applicable include controlled-circuit identification for each furniture receptacle and coordinate with th e building electrical system circuits in accordance with ASHRAE 90.1 - IP .
Critical dimensions include, but are not limited to clearances and aisle widths. Drawings must include layout for furniture systems worksta tions for coordination purposes. Label furniture with furniture item cod e
SECTION 12 50 00.13 10 Page 9 identified in this specification. Submit grommet, power and communication units, and wire management locations.
3.3.2 Furniture Installation Procedures
Complete installation in accordance with manufacturer's installation instructions, assembly manuals, warranty requirements and approved installation drawings. Also comply with the following requirements:
a. Use material handling equipment with rubber wheels.
b. Furniture and components must be installed level, plumb, square, and with proper alignment with adjoining furniture.
c. Match keys to locks and check locking mechanisms.
d. Check drawers, doors, lighting, and other operable items and mechanisms for proper operation.
e. Remove all protective wrapping tape, residue, and related type items.
f. Securely interconnect furniture components where required.
g. Securely attach and anchor furniture components to the building when required.
h. Securely anchor furniture such as shelving and storage units to the building when required by the manufacturer.
i. All items with an electrical plug, such as but not limited to task lighting and tables with electrical power, must be fully operational .
j. All hardwired furniture, such as but not limited to furniture systems, must be fully operational. Verify that voltage is present in electrical outlets. Verify controlled-circuit outlets are properly configured in accordance with the installation drawings.
k. Furniture must not block SIPRNET and jacks or the jack enclosures on walls. Report conflicts to Contracting Officer to discuss resolution.
l. Upon completion of installation, all furniture must be complete ly cleaned, finished, leveled, aligned, operational and functional.
m. Install artwork with security mount hardware as recommended by the manufacturer.
3.3.3 Furniture Communications Installation
Provide all Information/Technology (IT) cables (i.e., SIPRNET, NIPRNET, J-WIC'S, etc.), and phone wiring up to and including the face plate /box of all furniture as required and the services to install the cables, w iring and face plates/boxes in the furniture. Coordinate cable type, cable jacket and outlet jack color with Section 27 10 00 BUILDING TELECOMMUNICATIONS CABLING SYSTEM. Furniture communication install ers must be on site to install communication cables, wiring and other components for furniture during furniture installation. Coordinate the TIA-568.2 pin/pair assignments for communication outlets to match the configuration of the building's non-furniture outlets; coordinate w ith
SECTION 12 50 00.13 10 Page 10
Contracting Officer. All items with a communication interface must be fully operational. Installation of Information/Technology (IT) wiring, cables and face plates/boxes in the furniture will be completed by others.
3.4 CLEANING
Remove all packing materials and other trash from the job site. Upon completion of installation, all products must be clean, including inside all drawers and doors, and the area must be free of debris and left in a clean and neat condition. Any defects in or damage to furniture must be repaired or replaced and approved by the Contracting Officer. Damaged products that cannot be satisfactorily repaired must be replaced. Correct any problems with assembly and installation. Prior to any furniture repair, replacement, and/or assembly and installation corrections, protect the building surfaces.
3.5 OPERATION AND MAINTENANCE MANUALS
Submit the Furniture, Data Package 1 in accordance with Section 00 80 00.00 06 SPECIAL PROVISIONS. and include the following:
3.5.1 Assembly Manuals
Describe assembly and re-configuration procedures. Provide three sets of installation video tapes if available.
3.5.2 Installation Instructions
Provide a copy of the instructions used to install the furniture. Also describe any special procedures or helpful hints learned during the installation process.
3.5.3 Maintenance Manuals
Describe proper cleaning and minor repair procedures, include cleaning instructions for fabrics.
3.5.4 Electrical System Manuals
Describe the functions, configuration, and maintenance of the furniture electrical system (power, communication, and data). This informati on may be included in the assembly or maintenance manuals.
3.5.5 Special Tools
Provide three sets of special tools necessary for assembly and disa ssembly of furniture and components from each manufacturer. Mark tool(s) with manufacturer and product information.
3.5.6 Furniture Drawings
Provide hard copy and electronic, showing installed furniture layou t.
Include all modifications. Provide electronic copies on a CD-ROM.
Coordinate type (such as but not limited to AutoCad and Revit) and version required with User. Include critical dimensions, and locations of building and furniture electrical and communications. Provide draw ings at 1/4 inch = 1 foot scale, unless otherwise specified. Provide typic al plans and isometrics/elevations of workstations at a scale of 1/2 i nch = 1 foot. Code all furniture with furniture item code identified in th is
SECTION 12 50 00.13 10 Page 11 specification.
3.5.7 Furniture Listing
Provide complete listing, hard copy and electronic, of furniture provided. Include all modifications. Provide electronic copies on a CD-ROM. Coordinate type of electronic file required with User (such as but not limited to Word and Excel). Listing must include furniture item code and name used in FF&E Package, part/model numbers, fabrics and finishes for all components furnished. Organize listing by item name and code and provide building totals.
3.5.8 Order Form Documentation
Provide Order Form Documentation with Purchase Order number and project name and location to allow the User to follow up on warranty issues and help with future purchases.
3.5.9 Key Control System
Provide system in excel format; indicate lock number, room number and location of lock within rooms if more than one lock number.
-- End of Section --
SECTION 12 50 00.13 10 Page 12
SECTION 12 59 00
SYSTEMS FURNITURE
08/17, CHG 1: 08/18
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING
ENGINEERS (ASHRAE)
ASHRAE 90.1 - IP (2013) Energy Standard for Buildings Except Low-Rise Residential Buildings
ASTM INTERNATIONAL (ASTM)
ASTM C423 (2009a) Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method
ASTM E84 (2023) Standard Test Method for Surface Burning Characteristics of Building Materials
ASTM E290 (2014) Bend Testing of Material for Ductility
BIFMA INTERNATIONAL (BIFMA)
ANSI/BIFMA M7.1 (2011; R 2016) Test Method for Determining VOC Emissions from Office Furniture Systems, Components and Seating
ANSI/BIFMA X5.5 (2014) American National Standards For Office Furnishings -Desk Products
ANSI/BIFMA X5.6 (2016) American National Standards For Office Furnishings -Panel Systems
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)
NEMA WD 1 (1999; R 2020) Standard for General Color Requirements for Wiring Devices
NEMA WD 6 (2021) Wiring Devices Dimensions Specifications
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 70 (2020; TIA 22-1; ERTA 1 2022) National Electrical Code
NFPA 101 (2021; TIA 22-1; ERTA 1 2022) Life Safety
SECTION 12 59 00 Page 1
Code
NFPA 265 (2019) Standard Methods of Fire Tests for Evaluating Room Fire Growth Contribution of Textile or Expanded Vinyl Wall Coverings on Full Height Panels and Walls
SCIENTIFIC CERTIFICATION SYSTEMS (SCS)
SCS SCS Global Services (SCS) Indoor Advantage
TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA)
TIA-568.2 (2018d) Balanced Twisted-Pair Telecommunications Cabling and Components Standards
TIA-569 (2019e; Add 1 2022) Telecommunications Pathways and Spaces
U.S. DEPARTMENT OF ENERGY (DOE)
Energy Star (1992; R 2006) Energy Star Energy Efficiency Labeling System (FEMP)
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines
UNDERWRITERS LABORATORIES (UL)
UL 723 (2018) UL Standard for Safety Test for Surface Burning Characteristics of Building Materials
UL 1286 (2022) UL Standard for Safety Office Furnishings
UL 2818 (2013) GREENGUARD Certification Program For Chemical Emissions For Building Materials, Finishes And Furnishings
1.2 SUBMITTALS
Government approval is required for submittals with a "G" or "S" classification. Submittals not having a "G" or "S" classification are for information only. When used, a code following the "G" classification identifies the office that will review the submittal for the Govern ment.
Submit the following in accordance with Section 01 33 00 SUBMITTAL
PROCEDURES:
SD-02 Shop Drawings
Detail Drawings; G AFRC
SD-03 Product Data
SECTION 12 59 00 Page 2
Warranty; G AFRC
Workstations; G AFRC
Power and Communications; G AFRC
Communications; G AFRC
Recycled Content for system furniture components; S AFRC
Energy Star Label for Task Lighting; S AFRC
SD-04 Samples
Workstations; G AFRC
Samples; G AFRC
SD-06 Test Reports
Selected Components; G AFRC
Panel Acoustics; G AFRC
Fire Safety; G AFRC
Electrical System; G AFRC
SD-07 Certificates
Workstations; G AFRC
SD-10 Operation and Maintenance Data
Assembly Manuals; G AFRC
Maintenance Manuals; G AFRC
Cleaning; G AFRC
Electrical System; G AFRC
Maintenance Agreements; G AFRC
Installation; G AFRC
1.3 CERTIFICATIONS
1.3.1 Indoor Air Quality Certifications
1.3.1.1 Office Furniture Systems and Seating
Provide products certified to meet indoor air quality requirements by UL 2818 (Greenguard) Gold, SCS Global Services Indoor Advantage Gold, ANSI/BIFMA M7.1 Certification or provide certification by other third-party program that products meet the requirements of this Sec tion.
Provide current product certification documentation from certificat ion body. When product does not have certification, provide validation that
SECTION 12 59 00 Page 3 product meets the indoor air quality product requirements cited herein.
1.4 QUALITY ASSURANCE
1.4.1 General Safety
Provide workstation products free of rough or sharp edges. Provide panel supported components with a positive, integral locking device which secures components without the use of additional screws or clamps to prevent the components from being accidentally pulled or knocked off the panels. Provide desk-based workstation components with an option for a positive, integral locking device that secures components to the base units.
1.4.2 Fire Safety
Components must meet requirements for flame spread and smoke development as specified by NFPA 101 except as follows. Conduct testing in accordance with either ASTM E84 or UL 723 on the entire assembled panel of the worst case (most combustible) combination of fabric and interior construction.
In addition, fabric must meet the requirements of NFPA 265 . Do not exceed 25 for Class A for panel flame spread and 450 for Class A, B and C panel smoke development.
1.4.3 Electrical System
Task lights are required to be UL listed and installation of task lighting must meet the requirements of NFPA 70 . The electrical system must meet the requirements of UL 1286 . Submit three sets of electrical system manuals describing the functions, configuration, and maintenance of the electrical system (power, communications, data). This material may be included in the Assembly or Maintenance manuals at the Contractor's option.
1.4.4 Detail Drawings
Submit detail drawings showing communications, electronic data processing (EDP) and local area network (LAN); locations may be provided as a separate submittal from remaining workstation drawings. Provide drawing requirements, which are the furniture manufacturer's responsibility, as a single submittal. Provide electronic drawings to the user for future re-configuration in the software package requested by the user. In clude in the electronic drawings all modifications made during installati on. As a minimum, submit the following:
a. Overall reference drawings: Drawings showing workstation locations and overall plan view within each floor in a scale of 1/8 inch = 1 foot.
Layouts must reflect field verified conditions and clearly illustrate the overall space planning concept and intent.
b. Installation drawings: Drawings showing workstations, panels, components, and plan view within each floor. Identify workstations by workstation type; submit drawings showing the proposed workstation installation at a scale of 1/4 inch = 1 foot, unless otherwise specified. Installation drawings must reflect field verified conditions.
c. Workstation elevations: Dimensioned workstation elevations sho wing each type of workstation with panel frame configurations and all components identified with manufacturer's catalog numbers. Draw
SECTION 12 59 00 Page 4 elevations at 1/2 inch = 1 foot scale.
d. Panel drawings: Panel drawings showing locations and critical dimensions from finished face of walls, columns, panels, including clearances and aisle widths. Key assemblies to a legend which includes width, height, configuration and composition of frame covers finishes and fabrics (if different selections exist within a project), power or nonpower, connectors and wall mount hardware. Coordinate panel placement with location of electrical, voice/date LAN, SIPRNet, NIPERNet, mechanical and fire protection fixtures. Drawings must reflect field verified conditions.
e. Electrical drawings: Drawings showing power provisions including type and location of feeder components (service entry poles, base or ceiling feeds), activated power receptacles and other electrical components. Wiring configuration (circuiting, switching, internal and external connections) identified and a legend provided as applicable.
Identify which receptacles in typical furniture configurations will be connected to controlled building power circuits as applicable to meet ASHRAE 90.1 - IP requirements.