W912QR24R0034_B1244_Plans-0004.pdf

PDF 2 MB Posted

Attached to
Construction of a KC-46 Two-Bay Hangar at March Air Reserve Base (ARB), CA
Solicitation number
W912QR24R0034
Issued by

About this file

These mechanical and plumbing design drawings are part of the construction documents for an Addition/Alteration of Building 1244 at March Air Reserve Base, associated with the broader KC-46 Two-Bay Hangar project. The drawings (Sheet P-502, M-602) provide detailed technical specifications for mechanical systems including fan coil units, humidifiers, variable air volume terminal units, diffusers, registers, grilles, louvers, and control dampers. Key equipment includes two fan coil units (FCU-01, FCU-02), two humidifiers (HUM-01, HUM-02) with specific electrical and capacity requirements, and eight variable air volume terminal units serving different areas like the Parts Workshop, Instructor Suite, Classroom, and Cargo Loading areas. The documents specify technical details such as airflow rates, electrical specifications, mounting types, and installation notes for each piece of equipment.

View the file

Other files

File Type Posted
W912QR24R0034_KC-46A_Specs-0007.pdf PDF
W912QR24R0034_KC-46A_Plans-0006.pdf PDF
W912QR24R0034_B1244_Specs-0005.pdf PDF
W912QR24R0034_KC-46A_Specs-0005.pdf PDF
W912QR24R0034_B1244_Plans-0005.pdf PDF
W912QR24R0034_KC-46A_Plans-0005.pdf PDF
W912QR24R0034_KC-46A_Specs-0004.pdf PDF
W912QR24R0034_B1244_Specs-0004.pdf PDF
W912QR24R0034_KC-46A_Plans_Vol1-0004.pdf PDF
Site Visit Sign-In Sheet 3.6.25.pdf PDF
W912QR24R0034-0003.pdf PDF
Preproposal Conference - March ARB - 29 January 2025.pptx PPTX presentation
March ARB_Site Visit Sign-in Sheet.pdf PDF
W912QR24R0034-0002.pdf PDF
W912QR24R0034-0001.pdf PDF
W912QR24R0034_B1244_Specs_Vol3-0000.pdf PDF
W912QR24R0034_KC-46A_FFE-0000.pdf PDF
W912QR24R0034_KC-46A_Specs_Vol4-0000.pdf PDF
W912QR24R0034_B1244_Specs_Vol1-0000.pdf PDF
W912QR24R0034_KC-46A_Specs_Vol2-0000.pdf PDF
W912QR24R0034_KC-46A_SID-0000.pdf PDF
W912QR24R0034_KC-46A_Specs_Vol1-0000.pdf PDF
W912QR24R0034_B1244_Plans-0000.pdf PDF
W912QR24R0034_KC-46A_Plans_Vol1-0000.pdf PDF
W912QR24R0034_KC-46A_Specs_Vol3-0000.pdf PDF
W912QR24R0034_B1244_SID-0000.pdf PDF
W912QR24R0034_B1244_Specs_Vol2-0000.pdf PDF
W912QR24R0034_KC-46A_Plans_Vol2-0000.pdf PDF
W912QR24R0034_B1244_FFE-0000.pdf PDF
Show all 29

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

POST-INSTALLED CONCRETE ANCHOR SCHEDULE

ADHESIVE

TYPE SIZE

EMBED

LENGTH

CRITICAL

DISTANCE TO

FREE EDGE

SPACING

FACTORED SHEAR (LBS) FACTORED

TENSION (LBS)

(VERTICAL) (HORIZONTAL)

REFERENCE

#4 4" 1'-4"

ADHESIVE #6 6" 1'-0"

ADHESIVE #8 6" 6"

ADHESIVE #4 6" 6"

WEDGE 3/4"

WEDGE 5/8" 6"

11"x11" SQ6"

2 3/4"

/H12 S-506

/A7 S-506

/A14 S-552

/A8 S-519

/A14 S-301 3" 360 670

3"

3" - - -

3"

/A8 S-519 7"

- 3200 20

- 450 -2"

/A7 S-301

WEDGE 5/8" 8"2 3/4"/K6 S-521 300 200 14002 1/2"

ADHESIVE 1/2" 8"x8" SQ6 3/4"/L1 S-504 - 750 57008"

WITHIN 8" BELOW

COMPACTED

FILL PER SPECS

PIPE PER OTHER

DISCIPLINE DWGS

MIN

6"

"T

M

IN

"T

"T

M

IN

REINF PER PLAN

CONC FDTN PER

PLAN

M A

X

CONC FTG OR

FDTN PER PLAN

CONC STEM

WALL PER PLAN

M

IN

PIPE PER OTHER

DISCIPLINE DWGS

BOT OF TRENCHBACKFILL AND

RECOMPACT

TRENCH PER SPECS

GREATER THAN 3'-0" BELOW8" TO 3'-0" BELOW

PLACE CONC FILL

BEFORE FTG FOR FULL

WIDTH OF PIPE TRENCH

PIPE AND SLV

PER OTHER

DISCIPLINE DWGS

CONC FTG OR

FDTN PER PLAN

CONC STEM

WALL PER PLAN

M

IN

M A

X

/2

M

IN

ADD #4 X 3'-0" TOP CTR

ON INTERSECTING JTS

CJ OR CTJ

TYPICAL ADD BARS AT DISCONTINUOUS JOINTS

SLOPE SLOPE

S L

O P

E

SLOPE 1/2"

TO DRAIN

RAD = 18"

TH

ETA <

D

EG

CJ OR CTJ

2"

2"

(2) #4 X 3'-0" TOP

HOOK ENDS WHERE BAR

EXTENDS TO EDGE OF CONC

TYPICAL RE-ENTRANT CORNER BARS IN SLAB

NOTES:

1. DETAIL APPLIES TO BOTH ROUND AND SQUARE OR

RECTANGULAR OPNGS ("D" = HEIGHT OR WIDTH).

2. DIAGONAL BARS ARE REQUIRED FOR ALL OPENINGS

EXCEPT FLOOR DRAINS, BUT ADD BARS ARE NOT REQUIRED

WHERE NO REINFORCEMENT OR DECK FLUTES

INTERRUPTED BY OPENING.

3. REINFORCE OPENINGS WITH "D" LARGER THAN 3'-0" AS

INDICATED ON DRAWINGS.

ADD BARS:

MATCH AREA OF

INTERRUPTED REINF

(1) #5 CTR MIN

DIAG BARS:

(1) #5 CTR TYP

X 3'-0" FOR SQ OR

RECTANGULAR OPNG

L A

P S

P L

IC

E T

Y P

T Y

P

"D"

VVERTICAL

V H

O R

IZ

O

N T

A L

POST-INSTALLED

AHR

** CRITICAL DISTANCE TO FREE EDGE

M A

X

M

IN

6" MIN

FINISHED GRADE OR

PAVEMENT W/ EXP

JT PER CIVIL DWGS

ISOLATORS, AHR

RODS, AND GRT PER

EQUIP SUPPLIER

EQUIP PER OTHER

DISCIPLINE DWGS

#5@12"

OC EW T&B

COMPACTED

SUBGRADE

OR STRUCT FILL

0' - 4 1/2"

ROUGHEN AREA

UNDER PAD

#4@12" OC

EW TOP

#4 DWL PER

NOTES 4A

N O

T E

B

BASE PL, AHR RODS, AND

GRT PER EQUIP SUPPLIER

NOTES:

1. PROVIDE EQ-1 FOR INTERIOR EQUIPMENT AND EXTERIOR EQUIPMENT

ON CONCRETE PAVEMENT. PROVIDE EF-1 FOR OTHER EXTERIOR

EQUIPMENT. SEE OTHER DISCIPLINE DRAWINGS FOR EQUIPMENT

LOCATIONS.

2. PROVIDE STANDARD TYPE V OR TYPE VII EQUIPMENT ANCHOR RODS,

UNLESS OTHERWISE RECOMMENDED BY EQUIPMENT MANUFACTURER.

3. GROUT EQUIPMENT IN PLACE WITH NON-SHRINK GROUT, UNLESS

OTHERWISE RECOMMENDED BY EQUIPMENT MANUFACTURER.

4. FOR EQ-1 ONLY:

A. PROVIDE NUMBER OF DOWELS TO MATCH TOTAL CROSS-

SECTIONAL AREA OF ANCHOR RODS, EQUALLY SPACED AROUND

PAD WITH SPACING NOT TO EXCEED 12".

B. MININUM HEIGHT OF PAD ABOVE SURROUNDING FLOOR SLAB OR

PAVEMENT UNLESS NOTED OTHERWISE:

(1) 4" FOR PADS WITH 1" DIAMETER OR SMALLER ANCHOR RODS.

(2) 6" FOR PADS WITH ANCHOR RODS LARGER THAN 1" DIAMETER.

0' - 6"

6" MIN FOR < 1" DIA AHR RODS

9" MIN FOR 1" DIA OR LARGER

8"

3" MIN TO

EDGE OF

EQUIP

BASE UNO0' - 4 1/2"

3" MIN TO

EDGE OF

EQUIP

BASE UNO

ROUGHEN AREA

UNDER PAD

#4@12" OC

EW TOP

#4 DWL PER

NOTES 4A & 4B

N O

T E

C

BASE PL, AHR RODS, AND

GRT PER EQUIP SUPPLIER

NOTES:

1. PROVIDE EQ-2 FOR INTERIOR EQUIPMENT AND EXTERIOR EQUIPMENT ON

CONCRETE PAVEMENT. PROVIDE EF-1 FOR OTHER EXTERIOR EQUIPMENT.

SEE OTHER DISCIPLINE DRAWINGS FOR EQUIPMENT LOCATIONS.

2. PROVIDE STANDARD TYPE V OR TYPE VII EQUIPMENT ANCHOR RODS,

UNLESS OTHERWISE RECOMMENDED BY EQUIPMENT MANUFACTURER.

3. GROUT EQUIPMENT IN PLACE WITH NON-SHRINK GROUT, UNLESS

OTHERWISE RECOMMENDED BY EQUIPMENT MANUFACTURER.

4. FOR EQ-2 ONLY:

A. PROVIDE NUMBER OF DOWELS TO MATCH TOTAL CROSS-SECTIONAL

AREA OF ANCHOR RODS, EQUALLY SPACED AROUND PAD WITH

SPACING NOT TO EXCEED 12".

B. EPOXY GROUT DOWELS INTO FLOOR SLAB OR PAVEMENT WITH

4 1/2" MINIMUM EMBEDMENT.

C. MININUM HEIGHT OF PAD ABOVE SURROUNDING FLOOR SLAB OR

PAVEMENT UNLESS NOTED OTHERWISE:

(1) 4" FOR PADS WITH 1" DIAMETER OR SMALLER ANCHOR RODS.

(2) 6" FOR PADS WITH ANCHOR RODS LARGER THAN 1" DIAMETER.

0' - 6"

6" MIN FOR < 1" DIA AHR RODS

9" MIN FOR 1" DIA OR LARGER

8"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

S-503

FUT

S T

A N

D A

R D

C O

N C

R E

T E

D E

T A

IL

S

M A

R C

H A

IR

R

E S

E R

V E

B A

S E

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G J

R P

L

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

B U

R N

S A

N D

M c D

O N

N E

L L

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

IS

S

O U

R I

A M

A R

S H

A L L

J B

A N

H

M B

E T

Z

K S

N E

L L

A P

R

IL

C E

R T

IF

IE

D F

IN

A

L D

E S

IG

N

S U

B M

IT

T

A L

A D

D

IT

IO

N

A

L T

E R

A T

IO

N

O F

B U

IL

D

IN

G

F

O R

F U

T -P

A L L E

T S

T O

R A

G E

P D

P G

P

SCALE: NTS

A1

PIPE BELOW CONTINUOUS FOUNDATION

SCALE: NTS

E16

DETAIL

SCALE: NTS

A16

TYPICAL FLOOR DRAIN

SCALE: NTS

H16

DETAIL

SCALE: NTS

E1

WALL/SLAB OPENING

SCALE: NTS

L11

TYPICAL POST-INSTALLED ANCHOR

SCALE: NTS

L16

EQUIPMENT FOUNDATION (EF-1)

SCALE: NTS

E11

EQUIPMENT PAD (EQ-1)

SCALE: 3/4" = 1'-0"

E6

EQUIPMENT PAD (EQ-2)

A

M E

N D

/2

/2

R

E

No. S5406

R

S

T

A

T

E

E G

I S

T

E

O

F

CA

L

I

F

N

I

O

R

R

A

N

G

I

N

E E

R

E

D

P

S

O

F

E S

I

O

N

A

L

K

I

R

K

J . S

N

E

L

L

S

T

R

U

CT

U

R

A

L

EXP. 9/30/2026

03/18/2025

W

2Q R

R

_B

_P la ns

-0

ARIMS: 200A Disposition: Maintain for 15yrs after construction.

"H" MIN-FOR MULTIPLE

STEPS IN FTG, STEPS MUST

BE PLACED AS NOTED

CONTR OPTION TO

LAP SPLICE REBAR

BOT OF FTG WHERE

EARTH CAN STAND

VERT W/O SHORING

SLOPE AS

REQD FOR

EARTH STABILITY

1 1/2" CPRS MATL

"H" = 4'-0" MAX

EXTEND BOT

REINF 2'-0"

PAST STEP TYP

ADDL TYP VERT

REINF AT STEP

NOTES:

1. USE THIS DETAIL AS REQUIRED TO DEPRESS FOOTING TO FIRM

BEARING, OR TO GET BELOW UNDERGROUND PIPING, OR

WHEREVER CHANGE IN FOOTING ELEVATION OCCURS.

2. PLACE ALL CONCRETE AGAINST UNDISTURBED SOIL. IF SOIL IS

DISTURBED DURING CONCRETE PLACEMENT, REPLACE

DISTURBED SOIL WITH CONCRETE.

1' - 5 107/256"

"T

"T"

GRID

GRID

GRID

GRID

GRID

GRID GRID

GRID

CJ OR CTJ

SEALED IJ

DISCONTINUE

REINF TYP

SECOND STAGE

CONC PLACEMENT

CJ OR CTJ

SEALED IJ

DISCONTINUE

REINF TYP

INTERIOR

EXTERIOR

CONTR OPTION TO

REPLACE DIAMOND

IJ W/ CIRCLE

NOTES:

1. USE CIRCULAR OPTION WHERE NO FLOOR JOINTS INTERSECT.

NOTES:

1. FOR EXTERIOR ISOLATION JOINTS AT BRACED BAYS,

ENCASE ALL GUSSET PLATES AND BRACING MEMBERS

WITH SECOND STAGE CONCRETE PLACEMENT.

CJ OR CTJ

TYP (4) PLC

SEALED IJ

DISCONTINUE

REINF TYP

SECOND STAGE

CONC PLACEMENT

CORNER

CONTR OPTION TO

REPLACE DIAMOND

IJ W/ CIRCLE

SEALED IJ

DISCONTINUE

REINF TYP

SECOND STAGE

CONC PLACEMENT

RE-ENTRANT CORNER

CONTR OPTION TO

REPLACE DIAMOND

IJ W/ CIRCLE

TYP

4" M

IN

TYP4"

M

IN

TYP4"

M

IN

TYP4"

M

IN

SLAB EDGE

CJ OR CTJ

SLAB EDGE

SLAB EDGE CONTR OPTION TO

REPLACE DIAMOND

IJ W/ CIRCLE

SLAB EDGE

SECOND STAGE

CONC PLACEMENT

DAMAGE LAST THD TO

PREVENT REMOVAL*

TOC EL

PL WASHER THK PER

AISC 325 TABLE 14-2

HEAVY HEX NUT W/

JAMB NUT TO

HOLD IN POSITION*

AHR ROD OR

MACHINE BOLT

NOTES:

1. * NOT REQUIRED FOR MACHINE BOLTS

2. CONTRACTOR'S OPTION TO PROVIDE HEADED MACHINE BOLTS IN LIEU OF THREADED RODS.

3. FULLY THREADED RODS ARE NOT PERMITTED.

4. ANCHOR ROD MATERIAL PER GENERAL NOTES.

5. COVERED CANOPY ANCHOR ROD DIAMETER, THREADS, PROJECTION, ANCHOR BOLT GRADE BY BUILDING

SUPPLIER. MINIMUM COVERED CANOPY ANCHOR BOLT EMBEDMENT DEPTH, B, IS 1'-4".

D = DIAMETER

K = THREADS (2D+3" SINGLE NUT)

THREADS (3D+3" DOUBLE NUTS)

P = PROJECTION = K UNO

HEAVY HEX NUTANCHOR ROD SCHEDULE

D NOTES

3/8"

1/2"

5/8"

A*

2"

B

6"

7"

10"

3/4"

7/8"

1"

1'-0"

1 1/8"

1 1/4"

1 3/8"

1 1/2"

1 3/4"

2"

2"

2"

2"

3"

3"

3"

3"

4"

4"

4"

4"

1'-2"

1'-4"

1'-6"

1'-8"

1'-10"

2'-0"

2'-5"

2'-10"

A

B P

/2

K

D

MIN

1'-6" 1.5

B/TRENCH EXCAVATION

MUST NOT EXTEND

BELOW THIS LINE UNLESS

APPROVED BY THE

GEOTECHNICAL

ENGINEER

TRENCH

EXCAVATION, TYP

FOOTING

PIPE, TYP

BACKFILL PER

SPECS, TYP

GROUND LINE

NOTES:

1. CONTRACTOR MUST COORDINATE ALL PIPE

LOCATIONS WITH BUILDING FOUNDATION

REQUIREMENTS.

2. IF REQUIREMENTS AS SHOWN CANNOT BE MET,

STEP FOOTING PER "TYPICAL STEPPED FOOTING"

DETAIL.

3. DO NOT PLACE SLEEVES OR CONDUIT IN ISOLATED

SPREAD FOOTINGS. RUN AROUND OR BELOW THESE

FOOTINGS.

4. SLEEVES ARE NOT TO PASS THROUGH CONTINUOUS

FOOTINGS OR GRADE BEAMS, UNLESS NOTED

OTHERWISE. WHERE SLEEVES ARE PERMITTED,

LOCATE WITHIN MIDDLE THIRD OF FOOTING OR

GRADE BEAM DEPTH.

CONC FILL

8" DIA SCHED 80

PIPE BOLLARD

SEE ARCH DWGS

CONC SLAB

GALV BASE

PL1/2X12X1'-0"

W/ (4) PI AHR

PER SCHED

1/43

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

S-504

FUT

S T

A N

D A

R D

C O

N C

R E

T E

D E

T A

IL

S

M A

R C

H A

IR

R

E S

E R

V E

B A

S E

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G J

R P

L

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

B U

R N

S A

N D

M c D

O N

N E

L L

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

IS

S

O U

R I

A M

A R

S H

A L L

J B

A N

H

M B

E T

Z

K S

N E

L L

A P

R

IL

C E

R T

IF

IE

D F

IN

A

L D

E S

IG

N

S U

B M

IT

T

A L

A D

D

IT

IO

N

A

L T

E R

A T

IO

N

O F

B U

IL

D

IN

G

F

O R

F U

T -P

A L L E

T S

T O

R A

G E

P D

P G

SCALE: NTS

A1

TYPICAL STEP IN FOOTING

SCALE: NTS

E12

COLUMN ISOLATION JOINTS

SCALE: NTS

A12

TYPE VII ANCHOR ROD

SCALE: NTS

E1

TYPICAL UTILITIES PIPE PARALLEL TO FOOTING

A

M E

N D

/2

/2

SCALE: NTS

L1

INTERIOR BOLLARD DETAIL

R

E

No. S5406

R

S

T

A

T

E

E G

I S

T

E

O

F

CA

L

I

F

N

I

O

R

R

A

N

G

I

N

E E

R

E

D

P

S

O

F

E S

I

O

N

A

L

K

I

R

K

J . S

N

E

L

L

S

T

R

U

CT

U

R

A

L

EXP. 9/30/2026

03/18/2025

W

2Q R

R

_B

_P la ns

-0

4" FD-A

EWC-1

JS-1

SK-1

UR-2

UR-1

WC-2

WC-1

LAV-1

PLUMBING FIXTURE LEGEND

SIZE - FLOOR DRAIN

DUAL ELECTRIC WATER COOLER

JANITOR SINK

KITCHEN SINK

URINAL, ACCESSIBLE

URINAL

WATER CLOSET - ACCESSIBLE

WATER CLOSET

LAVATORY, COUNTER MOUNTED

HB-1 HOSE BIBB

WH-1 WALL HYDRANT

LAV-2 LAVATORY, WALL MOUNTED

MB-1 MOP BASIN

SK-2 SINK

EEWS-1 EMERGENCY EYEWASH / SHOWER

SH-1 SHOWER

SK-3 UNDER MOUNT SINK

WCO

FLOOR DRAIN / EQUIPMENT DRAIN

PLUMBING FIXTURE TRAP

FLOOR OR WALL PENETRATION

VENT THRU ROOF (VTR)

CLEANOUT (CO) IN RISER

RISER DIAGRAM LEGEND

CO

FCO

CLEANOUT (FCO) IN FLOOR

WATER HAMMER ARRESTORWHA-A

WALL CLEANOUT (WCO)

ISOMETRIC DIRECTION ARROW

UP

DN

3-WAY VALVE

2-WAY VALVE

ANGLE VALVE

AV

AUTOMATIC AIR VENT

ASSEMBLY

BFP

BACKFLOW PREVENTION

ASSEMBLY

BALANCING VALVE / CIRCUIT

SETTER

BALL VALVE

BLIND FLANGE

BUTTERFLY VALVE

CHECK VALVE

FLEX CONNECTION

FLOW ARROW

FM FLOW METER

GATE VALVE

GLOBE VALVE

HOSE GATE DRAIN VALVE

IF

INSULATING FLANGE

MV

MANUAL AIR VENT ASSEMBLY

- SEE SPECIFICATIONS FOR

APPROPRIATE VALVE TYPE

M METER

M MOTORIZED CONTROL VALVE

OS&Y

OUTSIDE SCREW & YOKE VALVE

PIPE WITH HEAT TRACE

PLUG VALVE

PRESSURE GUAGE

SELF CONTAINED PRESSURE

REDUCING (REGULATING)

VALVE

PUMP

REDUCER (CONCENTRIC)

RELIEF, SAFETY OR THERMAL

RELIEF VALVE

REMOVABLE CAP

REMOVABLE PLUG

S STRAINER

SUCTION DIFFUSER

TEST CONNECTION

THERMOMETER

UNION

Y-TYPE STRAINER

SRC SPRING RETURN CLOSED BALL

VALVE

PIPE ACCESSORIES SYMBOLS

PIPE SYMBOLS

PIPE ELBOW

PIPE DOWN

PIPE UP

PIPE CONTINUATION

PIPE LINE DESIGNATIONS

VENT

STORM (ABOVE GRADE)

STORM (BELOW GRADE)

STORM OVERFLOW

DOMESTIC COLD WATER

DOMESTIC HOT WATER

DOMESTIC HOT WATER RECIRCULATION

SANITARY SEWER (ABOVE GRADE)

SANITARY SEWER (BELOW GRADE)

CONDENSATE DRAIN (ABOVE GRADE)

COMPRESSED AIR

NATURAL GAS

CLEANOUT IN RISER

CLEANOUT IN WALL

CLEANOUT IN FLOOR

SS

SS

COND

V

DCW

DHW

DHWR

CA

NG

OD

S

S

CO

WCO

FCO

CONDENSATE DRAIN (BELOW GRADE)COND

REVERSE OSMOSISRO

EXISTING

DEMO

EXISTING

NEW WORK

(E) EXISTING

NEW

(D) DEMOLITION

(ETR) EXISTING

TO REMAIN

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

P-001

FUT

P L U

M B

IN

G

G E

N E

R A

L N

O T

E S

A

B B

R E

V

IA

T

IO

N S

M A

R C

H A

IR

R

E S

E R

V E

B A

S E

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G J

R P

L

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

B U

R N

S A

N D

M c D

O N

N E

L L

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

IS

S

O U

R I

A D

A R

R

B B

A L O

R A

N

M B

E T

Z

B S

C H

N

IE

R

C E

R T

IF

IE

D F

IN

A

L D

E S

IG

N

S U

B M

IT

T

A L

A D

D

IT

IO

N

A

L T

E R

A T

IO

N

O F

B U

IL

D

IN

G

F

O R

F U

T -P

A L L E

T S

T O

R A

G E

P D

P G

PLUMBING ABBREVIATIONS GENERAL NOTES:

CONSTRUCTION INTERFACE

AC AIR COCK

AFF ABOVE FINISHED FLOOR

AG AIR GAP

ARV AIR RELEASE VALVE

BF BLIND FLANGE

BFP BACKFLOW PREVENTER

BL BALANCING VALVE

BOP BOTTOM OF PIPE

BV BALANCING VALVE

BW BUTT WELD

CH OP CHAIN WHEEL OPERATOR

CONC CONCENTRIC

CORP STOP CORPORATION STOP

CP CONDENSATE PUMP

CPVC CHLORINATED POLYVINYL CHLORIDE

D DEMOLISH

DCW DOMESTIC COLD WATER

DHW DOMESTIC HOT WATER

DHWR DOMESTIC HOT WATER RETURN

DI DUCTILE IRON

DN DOWN

DWH DOMESTIC WATER HEATER

E EXISTING

ELL ELBOW

ET EXPANSION TANK

ETR EXISTING TO REMAIN

FCA FLANGED COUPLING ADAPTER

FD FLOOR DRAIN

FE FLANGED END

FF FLAT FACED

FI FLOW INDICATOR

FLGD FLANGED

FM FLOW METER

FOB FLAT ON BOTTOM

FOT FLAT ON TOP

FOV FLOAT OPERATED VALVE

FRP FIBERGLASS REINFORCED PIPE

FW FIELD WELD

GCO GROUND CLEAN OUT

HD HUB DRAIN

HR HOSE REEL

HUM HUMIDIFIER

I.E. INVERT ELEVATION

IF INSULATED FLANGE

LC LOCK CLOSED

LO LOCK OPEN

LR LONG RADIUS

NPSH NET POSITIVE SUCTION HEAD

NRS NON-RISING STEM

NWL NORMAL WATER LEVEL

PSIA POUNDS PER SQUARE INCH ABSOLUTE

PSIG POUNDS PER SQUARE INCH GAUGE

PVC POLYVINYL CHLORIDE

RED REDUCER-REDUCING

RO REVERSE OSMOSIS

RS RISING STEM

SCH SCHEDULE

SCRD SCREWED

SR SHORT RADIUS

TD TRENCH DRAIN

TOC TOP OF CONCRETE

TOG TOP OF GRATING

TOP TOP OF PIPE

TOS TOP OF STEEL

TP TRAP PRIMER

VTR VENT THROUGH ROOF

WM WATER METER

1. UNLESS NOTED OTHERWISE, THE CIVIL AND MECHANICAL INTERFACE POINT IS 5 FEET

OUTSIDE OF THE BUILDING WALL.

2. COORDINATE ALL PIPE SLEEVE REQUIREMENTS WITH FOUNDATION SUBCONTRACTOR.

3. COORDINATE MECHANICAL ROOM FLOOR DRAINS WITH ACTUAL EQUIPMENT LOCATIONS

AND DRAINAGE REQUIREMENTS.

4. LEGEND IS GENERAL IN NATURE AND NOT ALL ITEMS SHOWN MAY BE USED ON THIS

PROJECT.

5. INSTALL SANITARY PIPING WITH 2% SLOPE DOWNWARD IN DIRECTION OF FLOW. INSTALL

VENT PIPING WITH 1% SLOPE DOWNWARD TOWARD FIXTURE OR STACK.

6. ALL FIXTURES SHALL HAVE A P-TRAP INSTALLED.

7. PROVIDE ALL MATERIALS, VALVES, HANGERS, ETC. AND EQUIPMENT AND PERFORM ALL

LABOR REQUIRED TO INSTALL COMPLETE AND OPERABLE PLUMBING SYSTEMS AS

INDICATED ON THE DRAWINGS, AS SPECIFIED AND AS REQUIRED BY CODE.

8. INSTALL ALL PLUMBING FIXTURES, EQUIPMENT AND APPURTENANCES IN ACCORDANCE

WITH MANUFACTURER'S RECOMMENDATIONS, CONTRACT DOCUMENTS, AND APPLICABLE

CODES AND REGULATIONS.

9. COORDINATE CONSTRUCTION OF ALL PLUMBING WORK WITH STRUCTURAL, CIVIL,

ELECTRICAL WORK ETC., SHOWN ON OTHER CONTRACT DOCUMENT DRAWINGS.

10. MAINTAIN A MINIMUM OF 6' - 8 CLEARANCE TO UNDERSIDE OF PIPES, CONDUITS, ETC., THROUGHOUT ACCESS ROUTES AND IN MECHANICAL ROOMS.

11. LOCATE ALL PLUMBING EQUIPMENT FOR UNOBSTRUCTED ACCESS TO UNIT ACCESS

PANELS, CONTROLS, AND VALVING. PROVIDE ACCESS DOORS FOR VALVES AND

SPECIALTIES CONCEALED IN WALLS AND/OR ABOVE HARD LID CEILINGS IN ACCORDANCE

WITH 08 31 00.

12. VERIFY DIMENSIONS AND CONNECTION SIZE WITH FURNISHED EQUIPMENT.

13. ALL ELEVATIONS ARE ABOVE FINISHED FLOOR TO BOTTOM OF PIPE UNLESS NOTED

OTHERWISE.

DEMOLITION NOTES

1. THE GENERAL EXTENT OF DEMOLITION IS INDICATED ON THE PLANS. COMPLETELY DEMOLISH

ALL EXISTING PLUMBING SYSTEMS WITH THE EXCEPTION OF THE EXISTING SANITARY SEWER

LINES UNDER HANGAR BAY FLOOR. IN THE HANGAR BAY, REMOVE EXPOSED SURFACE

DRAINS AND SPECIALTIES, CAP THE LINE BELOW THE FLOOR, AND INFILL THE FLOOR.

SECTION CUT SYMBOL

A1

M-001

INDICATES PERSPECTIVE

AND LIMITS OF SECTION

SECTION

DESIGNATOR

DRAWING WHERE

SECTION IS SHOWN

DETAIL/SECTION TITLE

TITLE

A1

LOCATION WHERE

DETAIL / SECTION IS

SHOWN ON SHEET

SCALE:

DETAIL / ENLARGED

CALLOUT SYMBOL

A1

M-001

INDICATES

LIMITS OF

DETAIL/SECTION

DETAIL/SECTION

DESIGNATOR

SHEET WHERE

DETAIL/SECTION IS

SHOWN

06-19-24

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

M E

N D

/2

/2

W

2Q R

R

_B

_P la ns

-0

SEE PLANS FOR SIZE

DCW

EMCS

BFP TO

HUMIDIFIER

FROM

RO WATER

KEY NOTES:

BALL VALVE (TYP.)

RO MAKEUP WATER METER

NUTATING DISC WITH TOTALIZING

REGISTER AND PULSE OUTPUT.

RPZ BACKFLOW PREVENTER3

RO FILTER PACKAGE

• AUTO ISO VALVE

• DUPLEX SOFTENER AND BRINE

TANK

• 5 MICRON SEDIMENT PRE-FILTER

• CARBON FILTER

• RO FILTER

• PRESSURIZATION PUMP

• 40 GAL PRESSURIZED STORAGE

TANK

• CONDUCTIVITY METER

HUMIDIFIER STAND SUPPORT,

REFER TO HVAC

6 HUMIDIFIER, REFER TO

HVAC

HUMIDIFIER MAIN AND

PAN DRAINS. ROUTE TO

CONDENSATE RECEIVER

THROUGH DRAIN COOLER WITH

FUNNEL WITH AIR GAP

CONDENSATE RECEIVER

PUMP PACKAGE

CONDENSATE

TO MECHANICAL ROOM

FLEXIBLE STEAM HOSE

TO AHU STEAM MANIFOLD, REFER

TO HVAC

SEE PLANS FOR SIZE

NOTES:

1. CONDENSATE RECEIVER WILL ALSO PUMP AHU AIR CONDITIONING CONDENSATE.

VENT TO ATMOSPHERE11

STRAINER AND WATER HAMMER

ARRESTOR

RO WASTE TO DRAIN WITH AIR

GAP

DCW

RO

PIPING

P E

R F

O R

A T

IO

N

8"ø PVC PIPE WITH 1/4"ø HOLES 3" O.C. @ 90°

PATCH & SEAL

TO MATCH EXIST

GR.

FINISHED GRADE

4" THICK CONC.

COLLAR

PLUG CAP TO

SUIT. INSTALL

FLUSH TO GRADE

16"x16"

7'-0" MIN.CL

CD

VARIES

FACE OF (E) EXTERIOR WALL

COND. DRAIN FROM A.C. UNIT

EXIST. BLDG.

DRILL FOR DRAIN

PEA GRAVEL OR

SAND

1" CRUSHED STONE

HALF FILLED

BRACKET FROM

CEILING OR WALL

NOTES:

1.

HOSE REEL

CA MAIN

HOSE STOP

COMBINATION PRESSURE REGULATING

VALVE/IN-LINE FILTER WITH INTEGRAL

PRESSURE GAUGE; OPERATING RANGE 5 TO 150

PSIG; INTEGRAL 1 MICRON COALESCING FILTER.

1/2" QUICK DISCONNECT

CA HOSE REEL. SPRING REWIND, RATED FOR 150

PSI MINIMUM WORKING PRESSURE, HEAVY DUTY,

ALL STEEL CONSTRUCTION. PROVIDE WITH 50' OF

1/2" AIR HOSE WITH QUICK DISCONNECT.

COALESCER

FILTER(TYP.

OF 2 IN PARALLEL)

TO BUILDING

BALL VALVE

CAP

FULL PORT BALL VALVE

PRESSURE

REGULATOR W/ GAUGE

PARTICULATE FILTER

(TYP. OF 2) IN PARALLEL

FLOOR

PACKAGE TANK

MOUNTED

COMPRESSOR/DRYER

FLOW METER (TO EMCS)

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

P-502

FUT

P L U

M B

IN

G

D E

T A

IL

S

M A

R C

H A

IR

R

E S

E R

V E

B A

S E

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G J

R P

L

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

B U

R N

S A

N D

M c D

O N

N E

L L

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

IS

S

O U

R I

A D

A R

R

B B

A L O

R A

N

M B

E T

Z

B S

C H

N

IE

R

C E

R T

IF

IE

D F

IN

A

L D

E S

IG

N

S U

B M

IT

T

A L

A D

D

IT

IO

N

A

L T

E R

A T

IO

N

O F

B U

IL

D

IN

G

F

O R

F U

T -P

A L L E

T S

T O

R A

G E

P D

P G

SCALE: NTS

F10

HUMIDIFIER / RO SYSTEM FLOW DIAGRAM

SCALE: NTS

A1

DRYWELL

SCALE: NTS

H1

COMPRESSED AIR WITH HOSE REEL

SCALE: NTS

A10

COMPRESSED AIR SERVICE ENTRANCE

06-19-24

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

M E

N D

/2

/2

W

2Q R

R

_B

_P la ns

-0

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

M-602

FUT

M E

C H

A N

IC

A

L S

C H

E D

U L E

S

M A

R C

H A

IR

R

E S

E R

V E

B A

S E

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G J

R P

L

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

B U

R N

S A

N D

M c D

O N

N E

L L

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

IS

S

O U

R I

A D

A R

R

B B

A L O

R A

N

M B

E T

Z

B S

C H

N

IE

R

C E

R T

IF

IE

D F

IN

A

L D

E S

IG

N

S U

B M

IT

T

A L

A D

D

IT

IO

N

A

L T

E R

A T

IO

N

O F

B U

IL

D

IN

G

F

O R

F U

T -P

A L L E

T S

T O

R A

G E

P D

P G

FAN COIL UNIT SCHEDULE (FCU)

TAG LOCATION AIRFLOW (CFM) TOTAL (MBH) WEIGHT (LBS) NOTES

FCU-01 COMM RM 120 840 36 44 1,2,3

FCU-02 ELEC RM 121 840 36 44 1,2,3

NOTES:

1. INDOOR UNIT POWERED BY OUTDOOR.

2. PROVIDE WITH MANUFACTURER'S CONDENSATE LIFT PUMP.

3. PROVIDE MANUFACTURER'S BACNET GATEWAY.

HUMIDIFIER SCHEDULE (HUM)

TAG LOCATION / SERVICE MOUNTING TYPE

FLUID

TYPE

CAPACITY

(LBS/HR)

INPUT

(KW)

ELECTRICAL WEIGHT

(LBS)

NOTES

VOLTS PHASE FLA

HUM-01 PARTS WORKSHOP 117 24" FLOOR STAND ELECTRIC STEAM WATER 30 10 480 3 12 200 1,3,5,6,7,8

HUM-02 FUT BAY / AHU-03 24" FLOOR STAND ELECTRIC STEAM WATER 40 13.5 480 3 16.5 200 2,3,4,6,7,8

NOTES:

1. PROVIDE WITH UNIT-MOUNTED STEAM DISTRIBUTION UNIT WITH FREE ROOM DISCHARGE.

2. PROVIDE DUCT-MOUNTED STEAM DISPERSION UNIT WITH 3 FT ABSORPTION DISTANCE. INSTALL IN AHU-03 BLANK SECTION.

3 PROVIDE MANUFACTURER'S 24-INCH HIGH FLOOR STAND, BACNET COMM CARD, AND DRAIN COOLER WITH BRACKET.

4. PROVIDE MANUFACTURER'S STEAM HOSE, AIRFLOW SWITCH, DUCT-MOUNTED HUMIDISTAT, AND DUCT HIGH LIMIT HUMIDITY SWITCH.

5. PROVIDE MANUFACTURER'S DUCT MOUNTED HUMIDITY SENSOR.

6. PROVIDE CENTRAL REVERSE OSMOSIS WATER TREATMENT PACKAGE RATED FOR 0.24 GPM WITH DUPLEX SOFTENER, BRINE TANK, SEDIMENT, AND CARBON PRE-FILTERS, PUMP, CONTROLLER, TDS MONITOR, 40 GAL PRESSURIZED STORAGE TANK, AND PRESSURE GAUGES BY HUMIDIFIER MANUFACTURER. REFER TO F10/P-502.

7. PROVIDE MODULATING HUMIDITY CONTROL.

8. COMPLY WITH MANUFACTURER REQUIREMENTS FOR STEAM SUPPLY PIPING ELEVATION, SLOPE AND INTERMEDIATE DRAINS. ROUTE INTERMEDIATE DRAINS TO

CONDENSATE TANK.

VARIABLE AIR VOLUME TERMINAL UNIT SCHEDULE (VAV)

TAG AREA SERVED

EQUIPMENT

SERVED

COOLING

AIRFLOW (CFM)

MIN. AIRFLOW

(CFM)

MAX HEATING

AIRFLOW (CFM)

NECK SIZE

(IN)

TYPE CASING TYPE

EXTERNAL STATIC

PRESSURE

(IN W.C.)

SCR ELECTRIC HEATING

COIL DISCHARGE

SOUND LEVEL

(NC)

ELECTRICAL

WEIGHT

(LBS)

NOTES

CAPACITY

(KW)

EAT

(DEG. F)

LAT

(DEG. F)

VOLTS PHASE

VAV-01 PARTS WORKSHOP 117 AHU-01 1300 260 650 10 SINGLE DUCT SHUT OFF LINED FOIL FACED 0.5 6.8 55 88 20 480 3 110 1

VAV-02 INSTRUCTOR SUITE 108 AHU-01 380 80 190 6 SINGLE DUCT SHUT OFF LINED FOIL FACED 0.5 1.9 55 84.4 20 480 3 75 1

VAV-03 CLASSROOM 115 AHU-01 1020 600 600 10 SINGLE DUCT SHUT OFF LINED FOIL FACED 0.5 4.6 55 78.8 20 480 3 110 1

VAV-04 CARGO LOADING 112 AHU-01 400 80 200 6 SINGLE DUCT SHUT OFF LINED FOIL FACED 0.5 2.1 55 87.9 26 480 3 75 1

VAV-05 BRIEFING ROOM 113, CORRIDOR 101 AHU-01 310 65 155 6 SINGLE DUCT SHUT OFF LINED FOIL FACED 0.5 0.9 55 71.5 20 480 1 75 1

VAV-06 DEBRIEFING 114 AHU-01 155 30 80 6 SINGLE DUCT SHUT OFF LINED FOIL FACED 0.5 0.5 55 74.8 20 480 1 75 1

VAV-07 BREAKROOM 102, CORRIDOR 101 AHU-01 505 105 255 8 SINGLE DUCT SHUT OFF LINED FOIL FACED 0.5 1.3 55 70 20 480 1 85 1

VAV-08 HUDDLE RM 109, MAINTENANCE OFFICE 111 AHU-01 215 40 90 6 SINGLE DUCT SHUT OFF LINED FOIL FACED 0.5 1.0 55 88 20 480 1 75 1

NOTES:

1. PROVIDE UNIT WITH FIELD MOUNTED DIGITAL CONTROLLER IN NEMA 1 ENCLOSURE.

DIFFUSER, REGISTER, & GRILLE SCHEDULE (DRG)

TYPE DESCRIPTION

FACE SIZE

(IN)

SYSTEM DAMPER NOTES

A AIRFOIL SUPPLY GRILLE, 3/4-INCH BLADE SPACING, 0° DEFLECTION NA SUPPLY OPPOSED BLADE 1,2,3,4

B HEAVY DUTY RETURN GRILLE, 3/4-INCH BLADE SPACING, 0° DEFLECTION NA RETURN OPPOSED BLADE 1,2,3,4

C SQUARE PLAQUE DIFFUSER 24" X 24" SUPPLY - 1,2,3,4

D RECTANGULAR RETURN OR EXHAUST AIR GRILLE 24" X 24" EXHAUST OPPOSED BLADE 1,2,3,4

E PERFORATED RETURN DIFFUSER 24" X 24" RETURN / EXHAUST - 1,2,3,4

F RECTANGULAR RETURN OR EXHAUST AIR GRILLE 12" X 12" EXHAUST / TRANSFER OPPOSED BLADE 1,3,4

NOTES:

1. MATCH DIFFUSER NECK TO BRANCH DUCT SIZE.

2. PROVIDE WITH 24"x24" MODULE. REFER TO ARCHITECTURAL PLANS FOR REFLECTED CEILING PLAN FOR CEILING/MOUNTING TYPE

3. REFER TO PLAN FOR SIZE

4. PROVIDE WITH WHITE FINISH

LOUVER SCHEDULE (L)

TAG SERVICE

LOUVER SIZE

AIRFLOW

(CFM)

FREE AREA

VELOCITY

(FT/MIN)

PRESSURE DROP

(IN W.C.)

WIDTH

(IN)

HEIGHT

(IN)

L-01 EF-4 EXHAUST 24 18 900 43 710 0.071

L-02 AHU-03 OUTSIDE AIR INTAKE 24 24 1500 50 824 0.1

CONTROL DAMPER SCHEDULE (CD)

TAG SERVICE TYPE

DIMENSIONS

VOLTS NOTES

HEIGHT

(IN)

WIDTH

(IN)

DIAMETER

(IN)

CD-01 EF-03 EXHAUST AIR TWO POSITION CONTROL 12 12 N/A - 1,2

CD-02 EF-05 EXHAUST AIR TWO POSITION CONTROL 16 16 N/A - 1,2

CD-03 EF-04 EXHAUST AIR TWO POSITION CONTROL N/A N/A 12 - 1,2

CD-04 EF-02 EXHAUST AIR TWO POSITION CONTROL 38 38 N/A - 1,2

CD-05 EF-07 EXHAUST AIR TWO POSITION CONTROL 32 32 N/A - 1,2

CD-06 EF-01 EXHAUST AIR TWO POSITION CONTROL 38 38 N/A - 1,2

CD-07 AHU-03 OUTSIDE AIR INTAKE MODULATING CONTROL 24 24 N/A 24 VAC 2

NOTES:

1. FACTORY FAN INTERLOCK

2. PROVIDE WITH MODULATING ULTRA LOW LEAKAGE CONTROL DAMPER.

06-19-24

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

M E

N D

/2

/2

W

2Q R

R

_B

_P la ns

-0

FUT_Drawings_AM4
S-503 STANDARD CONCRETE DETAILS
S-504 STANDARD CONCRETE DETAILS
P-001 PLUMBING GENERAL NOTES, ABBREVIATIONS
P-502 PLUMBING DETAILS
M-602 MECHANICAL SCHEDULES

File details come from the government source that posted it. Updated .