Attachment_2_-_16V01ME_E1.11-SKE-2.pdf

PDF 115 KB Posted

Attached to
F-35 ALTER BUILDING 140 SQUAD OPS FACILITY Federal contract opportunity
Solicitation number
W912LN-17-B-1000
Issued by
Department of the Army Vermont Army National Guard

About this file

Attachment 2 Amended Drawing 16V01ME E1.11-SKE-2

View the file

Other files for this federal contract opportunity

Other files attached to F-35 ALTER BUILDING 140 SQUAD OPS FACILITY, newest first.
File Type Posted
W912LN-17-C-1000.pdf PDF
W912LN-17-B-1000_Amendment_0001.pdf PDF
Attachment_3_-_Roof_Warranty.pdf PDF
Attachment_1_-_16V01ME_E1.10-SKE-1.pdf PDF
Pre_Proposal_Minutes.pdf PDF
B-140_Pre-Bid.pptx PPTX presentation
B140_Site_Visit_Attendance_Roster.pdf PDF
0705 - B-3 Project Manual 021017.pdf PDF
21-S1.0 - B140.pdf PDF
03-0705-XC Floor Plans.pdf PDF
0705-CD B3 F-35 Plan-ALIS.pdf PDF
10-0705-CD B3 Wall Types.pdf PDF
13-0705-CD B3 Stairs.pdf PDF
31-16V01ME Plumbing B-3 Submission 20170209.pdf PDF
16V01ME-ALIS Electrical B3 Submission 20170208.pdf PDF
18-0705-CD B3 Windows.pdf PDF
B140_Squad_OPS.zip ZIP file
05-0705-XC Sections.pdf PDF
06-0705-CD B3 Site Plan.pdf PDF
20-0705-CD B3 Interior Details.pdf PDF
09-0705-CD B3 Roof Details.pdf PDF
02-Civil Plans B140 2-10-2017.pdf PDF
0705-Project Manual 021017 F35.pdf PDF
14-0705-CD B3 Int elev A-6-0-6.pdf PDF
32-16V01ME Fire Protection B3 Submission 20170208.pdf PDF
27-S3.2 - B140.pdf PDF
04-0705-XC Exterior Elevations.pdf PDF
15-0705-CD B3 Int elev A-6-7-13.pdf PDF
12-0705-CD B3 Sections.pdf PDF
23-S1.2 - B140.pdf PDF
11-0705-CD B3 Ext Elev.pdf PDF
22-S1.1 - B140.pdf PDF
25-S2.2- B140.pdf PDF
07-0705-CD B3 Plans.pdf PDF
08-0705-CD B3 Roof Plan.pdf PDF
16-0705-CD B3 Int elev A-6-14-18.pdf PDF
26-S3.1 - B140.pdf PDF
Civil Plans B140 2-10-2017.pdf PDF
28-S3.3 - B140.pdf PDF
01-0705-CD B3 Alter B-140 Cover.pdf PDF
16112ME- ALIS Mechanical B3 Submission 20170209.pdf PDF
17B1000_11_May_17.pdf PDF
29-16V01ME Mechanical B3 Submission 20170209.pdf PDF
17-0705-CD B3 Doors.pdf PDF
16112ME Lighting Photometrics.pdf PDF
19-0705-CD B3 Exterior Details.pdf PDF
0705-CD B3 F-35 Cover-ALIS.pdf PDF
30-16V01ME Electrical B3 Submission 20170209.pdf PDF
24-S2.1 - B140.pdf PDF
Show all 49

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A R C H I T E C T S

1 1 7 S t. P a u l S t r e e t 3 r d F l o o r

B u r l i n g t o n, V T 0 5 4 0 1

P: 8 0 2 • 8 6 3 • 2 2 2 7 F: 8 0 2 • 8 6 3 • 0 0 9 3

SCALE:

8" = 1'-0"

DRAWING:PROJECT:

DATE:

05/24/17

SKE-2

LOWER FLOOR CABLE

TRAY REVISIONSALTER B-140 SQUAD OPS FACILITY

VERMONT AIR NATIONAL GUARD, SOUTH BURLINGTON, VERMONT PROJECT NO. 0705

ALVAR E Z

SIENKIEWYCZ

S M I T H

REFER TO DRAWING E1.11

66 Jackson Street Littleton, NH 03561

603.444.6578 www.yeatonassociates.com

16V01ME

X:

\1

6V

M E

VT

AN

G B

SQ

U

AD

O

PS

F ac ili ty \1

6V

M E

E1 .1

1.

dw g

AutoCAD SHX Text

UP

AutoCAD SHX Text

COMM ROOM

AutoCAD SHX Text

AutoCAD SHX Text

MAN TRAP

AutoCAD SHX Text

AutoCAD SHX Text

LOBBY

AutoCAD SHX Text

AutoCAD SHX Text 4"X2" C.T.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text CABLE TRAYS KEYNOTES ` ' ' 1. EXISTING ABOVE CEILING CABLE. ACTUAL LOCATION AND SIZE MAY VARY, AS EXISTING ABOVE CEILING CABLE. ACTUAL LOCATION AND SIZE MAY VARY, AS TRANSFERRED AND SHOWN FROM EXISTING RECORD DRAWINGS. 2. EXTEND EXISTING CABLE TRAY. FIELD VERIFY EXISTING SIZE. PROVIDE 12" EXTEND EXISTING CABLE TRAY. FIELD VERIFY EXISTING SIZE. PROVIDE 12" WIDE BY 2" DEEP WIRE BASKET TRAY AS A MINIMUM AND PROVIDE ASSOCIATED ACCESSORIES TO MATCH UP WITH EXISTING, INCLUDING GROUNDING. 3. PROVIDE 18" WIDE LADDER RACK WITH 9" RUNG SPACING AND FACTORY 90 PROVIDE 18" WIDE LADDER RACK WITH 9" RUNG SPACING AND FACTORY 90 DEGREE TURNS IN THE CORNERS. PROVIDE 18" CABLE RADIUS DROPS ONE FOR EACH NEW RACK AND PROVIDE ALL MOUNTING HARDWARE FOR A COMPLETE LADDER RACK INSTALLATION. SEE SPECIFICATION 271005, 2.11 FOR ADDITIONAL REQUIREMENTS AND INFORMATION. 4. LOCATION OF EXISTING ABOVE CEILING CONDUITS, BASED ON EXISTING LOCATION OF EXISTING ABOVE CEILING CONDUITS, BASED ON EXISTING RECORD DRAWINGS AND FIELD OBSERVATIONS SHOWN FOR COORDINATION PURPOSES. 5. EXISTING THRU WALL CONDUIT SLEEVES, BASED ON EXISTING RECORD EXISTING THRU WALL CONDUIT SLEEVES, BASED ON EXISTING RECORD DRAWINGS AND FIELD OBSERVATIONS. SHOWN FOR COORDINATION PURPOSES. 6. THIS SECTION OF CABLE TRAY SHALL BE MOUNTED ABOVE THE SERVER THIS SECTION OF CABLE TRAY SHALL BE MOUNTED ABOVE THE SERVER RACK LOCATIONS. FIELD COORDINATE EXACT LOCATIONS WITH THE OWNER.

AutoCAD SHX Text

AutoCAD SHX Text CABLE TRAYS KEYNOTES ` ' ' 1. EXISTING ABOVE CEILING CABLE. ACTUAL LOCATION AND SIZE MAY VARY, AS EXISTING ABOVE CEILING CABLE. ACTUAL LOCATION AND SIZE MAY VARY, AS TRANSFERRED AND SHOWN FROM EXISTING RECORD DRAWINGS. 2. EXTEND EXISTING CABLE TRAY. FIELD VERIFY EXISTING SIZE. PROVIDE 12" EXTEND EXISTING CABLE TRAY. FIELD VERIFY EXISTING SIZE. PROVIDE 12" WIDE BY 2" DEEP WIRE BASKET TRAY AS A MINIMUM AND PROVIDE ASSOCIATED ACCESSORIES TO MATCH UP WITH EXISTING, INCLUDING GROUNDING. 3. PROVIDE 18" WIDE LADDER RACK WITH 9" RUNG SPACING AND FACTORY 90 PROVIDE 18" WIDE LADDER RACK WITH 9" RUNG SPACING AND FACTORY 90 DEGREE TURNS IN THE CORNERS. PROVIDE 18" CABLE RADIUS DROPS ONE FOR EACH NEW RACK AND PROVIDE ALL MOUNTING HARDWARE FOR A COMPLETE LADDER RACK INSTALLATION. SEE SPECIFICATION 271005, 2.11 FOR ADDITIONAL REQUIREMENTS AND INFORMATION. 4. LOCATION OF EXISTING ABOVE CEILING CONDUITS, BASED ON EXISTING LOCATION OF EXISTING ABOVE CEILING CONDUITS, BASED ON EXISTING RECORD DRAWINGS AND FIELD OBSERVATIONS SHOWN FOR COORDINATION PURPOSES. 5. EXISTING THRU WALL CONDUIT SLEEVES, BASED ON EXISTING RECORD EXISTING THRU WALL CONDUIT SLEEVES, BASED ON EXISTING RECORD DRAWINGS AND FIELD OBSERVATIONS. SHOWN FOR COORDINATION PURPOSES. 6. THIS SECTION OF CABLE TRAY SHALL BE MOUNTED ABOVE THE SERVER THIS SECTION OF CABLE TRAY SHALL BE MOUNTED ABOVE THE SERVER RACK LOCATIONS. FIELD COORDINATE EXACT LOCATIONS WITH THE OWNER.

Sheets and Views
16V01ME E1.11-SKE-2

File details come from the government source that posted it. Updated .