17-0705-CD B3 Doors.pdf

PDF 5 MB Posted

Attached to
F-35 ALTER BUILDING 140 SQUAD OPS FACILITY Federal contract opportunity
Solicitation number
W912LN-17-B-1000
Issued by
Department of the Army Vermont Army National Guard

About this file

Not Listed

View the file

Other files for this federal contract opportunity

Other files attached to F-35 ALTER BUILDING 140 SQUAD OPS FACILITY, newest first.
File Type Posted
W912LN-17-C-1000.pdf PDF
Attachment_2_-_16V01ME_E1.11-SKE-2.pdf PDF
W912LN-17-B-1000_Amendment_0001.pdf PDF
Attachment_3_-_Roof_Warranty.pdf PDF
Attachment_1_-_16V01ME_E1.10-SKE-1.pdf PDF
Pre_Proposal_Minutes.pdf PDF
B140_Site_Visit_Attendance_Roster.pdf PDF
B-140_Pre-Bid.pptx PPTX presentation
16112ME- ALIS Mechanical B3 Submission 20170209.pdf PDF
17B1000_11_May_17.pdf PDF
29-16V01ME Mechanical B3 Submission 20170209.pdf PDF
16112ME Lighting Photometrics.pdf PDF
19-0705-CD B3 Exterior Details.pdf PDF
0705-CD B3 F-35 Cover-ALIS.pdf PDF
30-16V01ME Electrical B3 Submission 20170209.pdf PDF
24-S2.1 - B140.pdf PDF
16V01ME-ALIS Electrical B3 Submission 20170208.pdf PDF
18-0705-CD B3 Windows.pdf PDF
B140_Squad_OPS.zip ZIP file
05-0705-XC Sections.pdf PDF
06-0705-CD B3 Site Plan.pdf PDF
20-0705-CD B3 Interior Details.pdf PDF
09-0705-CD B3 Roof Details.pdf PDF
02-Civil Plans B140 2-10-2017.pdf PDF
0705-Project Manual 021017 F35.pdf PDF
14-0705-CD B3 Int elev A-6-0-6.pdf PDF
32-16V01ME Fire Protection B3 Submission 20170208.pdf PDF
27-S3.2 - B140.pdf PDF
0705 - B-3 Project Manual 021017.pdf PDF
21-S1.0 - B140.pdf PDF
03-0705-XC Floor Plans.pdf PDF
0705-CD B3 F-35 Plan-ALIS.pdf PDF
10-0705-CD B3 Wall Types.pdf PDF
13-0705-CD B3 Stairs.pdf PDF
31-16V01ME Plumbing B-3 Submission 20170209.pdf PDF
04-0705-XC Exterior Elevations.pdf PDF
15-0705-CD B3 Int elev A-6-7-13.pdf PDF
12-0705-CD B3 Sections.pdf PDF
23-S1.2 - B140.pdf PDF
11-0705-CD B3 Ext Elev.pdf PDF
22-S1.1 - B140.pdf PDF
25-S2.2- B140.pdf PDF
07-0705-CD B3 Plans.pdf PDF
08-0705-CD B3 Roof Plan.pdf PDF
16-0705-CD B3 Int elev A-6-14-18.pdf PDF
26-S3.1 - B140.pdf PDF
Civil Plans B140 2-10-2017.pdf PDF
28-S3.3 - B140.pdf PDF
01-0705-CD B3 Alter B-140 Cover.pdf PDF
Show all 49

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

B. C. D.A. E.

'-0

- 9

'-9

V

IF

9' -0

9' -1

0"

EQ

EQ

EQ

9'-10"

EQ. EQ.

REMOVABLE ASTRAGAL, REFER

TO HARDWARE SPECIFICATIONS

FOR LOCATIONS

9' -9

+/- 5'-9"

A. B. C.

D. E. INTERIOR ALUM. F. G. H.

VIFVIF

+/- 6'-4"

VIF

TEMPERED GLASS DOOR

AS PART OF GLASS WALL

SYSTEM

CLEAR

TRANSLUCENT FILM; REFER

TO INTERIOR ELEVATIONS

FOR LOCATIONS.

MOUNTING HEIGHT AND

FILM SIZE VARIES - TYPICAL

SHOWN.

+/- 2'-3 1/2" +/- 9'-8"

9' -0

I. INTERIOR ALUM. J. INTERIOR

ALUM.

+/- 6'-4"

VIF

3'-0"

1/4" GLAZING

1/4" GLAZING

VIF DOOR SCHEDULE,

ELEVATIONS AND

DETAILS

A-7.0

DOOR SCHEDULE

DOOR SIZE (NOMINAL) DOOR FRAME GLASS

NO. WIDTH HEIGHT THK ELEV MAT ELEV MAT HEAD JAMB THR RATING

STC

UL RATING HW SET REMARKS

001 3'0" 7'0" 1 3/4" C SCWD A HM 7/8" FIRE RESISTIVE 1 2 - 60 MIN 32

004 3'0" 7'0" 1 3/4" A SACWD A AHM 3 4 5 STC-45 07

005 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 14

006 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 14

007 3'0" 7'0" 1 3/4" A SACWD A AHM 3 4 5 STC-50 43

008 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 T2 11

009 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 60 MIN 18

010 3'0" 7'0" 1 3/4" A SACWD A AHM 3 4 5 STC-45 41

010.1 3'0" 7'0" 1 3/4" A SACWD B AHM 3 4 5 STC-45 40

011 3'0" 7'0" 1 3/4" A SACWD A AHM 3 4 5 STC-45 04

012 3'0" 7'0" 1 3/4" A SACWD A AHM 3 4 5 STC-50 01

013 3'0" 7'0" 1 3/4" A SACWD B AHM 51 52 5 STC-45 41

014 3'0" 7'0" 1 3/4" A SCWD B HM 53 54 T3 15

015 3'0" 7'0" 1 3/4" A SCWD B EXG HM - - T3 25

016 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 19

017 3'0" 7'0" 1 3/4" A EXG SCWD A EXG HM - - - 12

018 3'0" 7'0" 1 3/4" A EXG SCWD A EXG HM - - - 12

020 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 T2 20

022 3'0" 7'0" 1 3/4" A SCWD B HM 6 7 11

023 3'0" 7'0" 1 3/4" A SACWD A AHM 3 4 5 STC-50 01

024 3'0" 7'0" 1 3/4" A SACWD A AHM 3 4 5 STC-50 01

025 3'0" 7'0" 1 3/4" A EXG SCWD B EXG HM - - - 12

027 3'0" 7'0" 1 3/4" A SACWD A AHM 3 4 5 STC-50 27

027.1 3'0" 7'0" 1 3/4" A SACWD A AHM 3 4 5 STC-50 33

028 3'0" 7'0" 1 3/4" A SACWD A AHM 3 4 5 STC-50 01

029 3'0" 7'0" 1 3/4" A EXG SCWD A EXG HM - - T2 12

030 3'0" 7'0" 1 3/4" A SCWD B EXG HM - - T2 26

031 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 T2 14

032 3'0" 7'0" 1 3/4" A EXG SCWD A EXG HM - - T2 12

033 3'0" 7'0" 1 3/4" A EXG SCWD A EXG HM - - T2 12

034 3'0" 7'0" 1 3/4" A SACWD A AHM 3 4 5 STC-50 33

035 3'6" 7'0" 1 3/4" D EXG INS MTL A EXG HMI EXG 1" INS - - - 12

037 3'0" 7'0" 1 3/4" A SCWD A EXG HM - - T4 26

038 3'0" 7'0" 1 3/4" C SCWD A HM 7/8" FIRE RESISTIVE 1 2 - 60 MIN 36

100 6'0" 7'0" 1 3/4" B ALUM C ALUM 1" LAM INS 14 12 13 02

100.1 6'0" 7'0" 1 3/4" B ALUM A ALUM 1/4" TEMP 10 11 - 03

101.1 3'6" 8'0" 1/2" E GLASS - - 1/2" TEMP 43 43 28

101.2 3'6" 8'0" 1/2" E GLASS - - 1/2" TEMP 43 43 28

101.3 3'6" 8'0" 1/2" E GLASS - - 1/2" TEMP 43 43 28

102 3'0" 8'0" 1/2" E GLASS - - 1/2" TEMP 43,44 43,44 28

103 3'0" 8'0" 1/2" E GLASS - - 1/2" TEMP 43,44 45,46,47 43,44 28

104 3'0" 8'0" 1/2" E GLASS - - 1/2" TEMP 43,44 45,46,47 43,44 28

105 3'0" 8'0" 1/2" E GLASS - - 1/2" TEMP 43,44 45,46,47 43,44 28

106 3'0" 8'0" 1/2" E GLASS - - 1/2" TEMP 43,44 45,47 43,44 28

107 3'0" 7'0" 1 3/4" A SACWD A AHM 3 4 5 STC-50 31

108 3'0" 7'0" 1 3/4" A SACWD A AHM 59 60 5 STC-50 29

108.1 3'0" 7'0" 1 3/4" A SACWD A AHM 59 60 5 STC-50 29

110A 6'0" 7'0" 1 3/4" A SCWD A HM 1 2 (SIM.) - 23

111A 7'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 23

112A 6'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 22

113 3'0" 7'0" 1 3/4" A SACWD A AHM 3 4 5 STC-45 05

113.1 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 06

114 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 T3 SIM 30

118 3'0" 7'0" 1 3/4" A SCWD A HM 55 56 - 14

119 3'0" 7'0" 1 3/4" A SCWD A HM 57 58 - 14

120 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 T2 20

121 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 T3 15

124 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 T3 21

125 3'0" 7'0" 1 3/4" C SCWD A HM 7/8" FIRE RESISTIVE 1 2 - 60 MIN 32

126 6'0" 7'0" 1 3/4" B ALUM D ALUM 1" LAM INS 17 18 15,16 02

126.1 5'4" 7'0" 1 3/4" B ALUM E ALUM 1/4" TEMP 20 19 - 03 1-3'-0" LEAF, 1-2'-4" LEAF, VIF WIDTH

127 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 T3 15

127.1 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 15

127A 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 19

130 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 T1 17

131 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 T4 14

132 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 T4 10

133 3'0" 7'0" 1 3/4" A SCWD - WOOD 40 41 - 34

133A 3'0" 7'0" 1 3/4" A SCWD B HM 1 53 SIM. - 42

134 3'0" 7'0" 1 3/4" A SCWD A EXG HM - - T3 09

134.1 3'0" 7'0" 1 3/4" A SCWD B HM 6 SIM. 7 SIM. - 20

136 3'0" 7'0" 1 3/4" A SCWD B HM 8 9 - 11

137 8'0" 8'0" 1 3/4" A INS MTL A HMI 37 36 SIM. 34 SIM. 39

138 7'0" 7'0" 1 3/4" A INS MTL B HMI 35 36 34 39

140 4'0" 7'0" 1 3/4" A INS MTL EXG. A EXG HM EXG. EXG. EXG. 24

141 3'0" 7'0" 1 3/4" A INS MTL A HMI 35 SIM 36 34 38

142 3'0" 7'0" 1 3/4" EXG. A EXG SCWD EXG. A EXG HM EXG. EXG. EXG. 12

143 3'0" 7'0" 1 3/4" B SCWD A HM 1/4" TEMP 1 2 T2 14

143A 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 19

144 3'0" 7'0" 1 3/4" B SCWD A HM 1/4" TEMP 1 2 T2 14

146 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 14

147 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 14

148 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 11

149 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 11

152 5'9" 7'0" 1 3/4" B ALUM F ALUM 1" LAM INS 24 25 42 SIM. 02 1-3'-0" LEAF, 1-2'-9" LEAF

152.1 6'0" 7'0" 1 3/4" B ALUM I ALUM 1/4" TEMP 21 22,23 - 03

153 3'0" 7'0" 1 3/4" B ALUM J ALUM 1/4" TEMP, TR FILM 30 22 T3 37 REFER TO INTERIOR ELEVATION FOR TRANSLUCENT FILM LAYOUT

153.1 3'0" 7'0" 1 3/4" B ALUM G ALUM 1" LAM INS 26 28,29 27 13

154 3'0" 7'0" 1 3/4" B SCWD - WOOD 1/4" TEMP, TR FILM 40 41 - 35 REFER TO INTERIOR ELEVATION FOR TRANSLUCENT FILM LAYOUT

155 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 14

156 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 11

157 3'0" 8'0" 1/2" E GLASS - - 1/2" TEMP 48,49 50, 46 SIM 48,49 28

158 3'6" 7'0" 1 3/4" D INS MTL A HMI 1" LAM INS 31 32 33, 15 16

159 3'0" 7'0" 1 3/4" B ALUM H ALUM 1" LAM INS 38 39 42 13

159.1 3'0" 7'0" 1 3/4" EXG. C EXG SCWD EXG. C EXG HM EXG. 1/4" WIRE EXG. EXG. EXG. EXG. 60 MIN. 08

SCWD SOLID CORE WOOD (DOOR)

SACWD SOLID ACOUSTIC CORE WOOD (DOOR)

HM HOLLOW METAL (FRAME)

AHM ACOUSTIC HOLLOW METAL (FRAME)

INS MTL INSULATED METAL (DOOR)

HMI HOLLOW METAL, INSULATED (FRAME)

ALUM ALUMINUM (DOOR AND FRAME)

TEMP TEMPERED GLASS

INS INSULATED GLASS

LAM, INS INSULATED GLASS WITH INTERIOR

LAMINATED PANE (BLAST MITIGATION)

TR FILM TRANSLUCENT FILM

STC SOUND TRANSMISSION CLASS

UL UL FIRE RATING

HW SET HARDWARE SET; REFER TO SPEC. SECTION 087100

ABBREVIATIONS FOR DOOR SCHEDULE

(STC-50 WALL SHOWN)

FILL HEAD

SOLID W/

GROUT

COMPRESSION

SOUND SEAL

(STC-50 WALL SHOWN)

FILL JAMB

SOLID W/

GROUT

COMPRESSION

SOUND SEAL

SWING OF DOOR TO

OPEN POSITION

N

ET

D O

O R

H

EI

G H

T

JA

M

P O

PE

N

IN

G

H

EI

G H

T

1/ 4"

1 1/2"

COORDINATE CONDUIT REQUIREMENTS FOR SECURITY

HARDWARE WITH ELECTRICAL DRAWINGS

COORDINATE CONDUIT REQUIREMENTS FOR SECURITY

HARDWARE WITH ELECTRICAL DRAWINGS

GROUT CORE AT JAMB

BLOCK SOLID

4"

SEALANT

GROUT CORE AT JAMB

BLOCK SOLID

DOOR DETAILS

A-7.1

SLOPE 1/8" PER FOOT

6" x 2 1/2", 12 GA. STUDS @ 8" O.C.

EXG. STUD (ASSUMED)

A-7.2

A-7.3

GROUT CORE AT JAMB

BLOCK SOLID

FILL HEAD SOLID

W/ GROUT

COMPRESSION

SOUND SEAL

FILL JAMB SOLID

W/ GROUT

COMPRESSION

SOUND SEAL

COORDINATE CONDUIT

REQUIREMENTS FOR

SECURITY HARDWARE WITH

ELECTRICAL DRAWINGS

COORDINATE CONDUIT

REQUIREMENTS FOR

SECURITY HARDWARE WITH

ELECTRICAL DRAWINGS

DOOR DETAILS

A-7.4

SEE PLAN FOR PARTITION TYPE

SEE PLAN FOR PARTITION TYPE

SEE PLAN FOR PARTITION TYPE

SEE PLAN FOR PARTITION TYPE

FILL HEAD SOLID

W/ GROUT

GROUT CORE AT JAMB

BLOCK SOLID

FILL JAMB SOLID

W/ GROUT

1 1/2" METAL FURRING, PNT

FLAT BLACK

5/8" GWB, FIRE TAPE, PNT

FLAT BLACK

FILL HEAD SOLID

W/ GROUT

COMPRESSION

SOUND SEAL

FILL JAMB SOLID

W/ GROUT

COMPRESSION

SOUND SEAL

COORDINATE CONDUIT REQUIREMENTS FOR SECURITY

HARDWARE WITH ELECTRICAL DRAWINGS

COORDINATE CONDUIT REQUIREMENTS FOR SECURITY

HARDWARE WITH ELECTRICAL DRAWINGS

A-7.0-Door Schedule, Elevations, and Details
Viewport-12
Viewport-3
schedule
Viewport-13
Viewport-5
1/A-7.0
1/A-7.2
Viewport-7
Viewport-9
A-7.1-Door Schedule, Elevations, and Details
1/A-7.1
1/A-7.4
1/A-7.5
1/A-7.7
1/A-7.6
1/A-7.9
1/A-7.11
1/A-7.12
1/A-7.13
1/A-7.15
1/A-7.17
1/A-7.26
A-7.2-Door Schedule, Elevations, and Details
1/A-7.16
1/A-7.18
1/A-7.19
1/A-7.21
1/A-7.22
1/A-7.24
1/A-7.25
1/A-7.27
1/A-7.23
1/A-7.28
1/A-7.30
1/A-7.29
1/A-7.32
1/A-7.34
1/A-7.31
1/A-7.33
A-7.3-Door Schedule, Elevations, and Details
1/A-7.46
1/A-7.36
1/A-7.38
1/A-7.40
1/A-7.39
1/A-7.42
1/A-7.43
1/A-7.44
1/A-7.48
1/A-7.49
1/A-7.51
1/A-7.53
1/A-7.54
Viewport-6
Viewport-10
Viewport-14
Viewport-16
A-7.4-Door Schedule, Elevations, and Details
1/A-7.8
Viewport-8
Viewport-15
Viewport-18
Viewport-20
Viewport-21
Viewport-23
Viewport-17
Viewport-22
1/A-7.14
1/A-7.35
Viewport-11
Viewport-24
3/A-7.0
3/A-7.2
3/A-7.4
3/A-7.6

File details come from the government source that posted it. Updated .