Text version
B. C. D.A. E.
'-0
- 9
'-9
V
IF
9' -0
9' -1
0"
EQ
EQ
EQ
9'-10"
EQ. EQ.
REMOVABLE ASTRAGAL, REFER
TO HARDWARE SPECIFICATIONS
FOR LOCATIONS
9' -9
+/- 5'-9"
A. B. C.
D. E. INTERIOR ALUM. F. G. H.
VIFVIF
+/- 6'-4"
VIF
TEMPERED GLASS DOOR
AS PART OF GLASS WALL
SYSTEM
CLEAR
TRANSLUCENT FILM; REFER
TO INTERIOR ELEVATIONS
FOR LOCATIONS.
MOUNTING HEIGHT AND
FILM SIZE VARIES - TYPICAL
SHOWN.
+/- 2'-3 1/2" +/- 9'-8"
9' -0
I. INTERIOR ALUM. J. INTERIOR
ALUM.
+/- 6'-4"
VIF
3'-0"
1/4" GLAZING
1/4" GLAZING
VIF DOOR SCHEDULE,
ELEVATIONS AND
DETAILS
A-7.0
DOOR SCHEDULE
DOOR SIZE (NOMINAL) DOOR FRAME GLASS
NO. WIDTH HEIGHT THK ELEV MAT ELEV MAT HEAD JAMB THR RATING
STC
UL RATING HW SET REMARKS
001 3'0" 7'0" 1 3/4" C SCWD A HM 7/8" FIRE RESISTIVE 1 2 - 60 MIN 32
004 3'0" 7'0" 1 3/4" A SACWD A AHM 3 4 5 STC-45 07
005 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 14
006 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 14
007 3'0" 7'0" 1 3/4" A SACWD A AHM 3 4 5 STC-50 43
008 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 T2 11
009 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 60 MIN 18
010 3'0" 7'0" 1 3/4" A SACWD A AHM 3 4 5 STC-45 41
010.1 3'0" 7'0" 1 3/4" A SACWD B AHM 3 4 5 STC-45 40
011 3'0" 7'0" 1 3/4" A SACWD A AHM 3 4 5 STC-45 04
012 3'0" 7'0" 1 3/4" A SACWD A AHM 3 4 5 STC-50 01
013 3'0" 7'0" 1 3/4" A SACWD B AHM 51 52 5 STC-45 41
014 3'0" 7'0" 1 3/4" A SCWD B HM 53 54 T3 15
015 3'0" 7'0" 1 3/4" A SCWD B EXG HM - - T3 25
016 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 19
017 3'0" 7'0" 1 3/4" A EXG SCWD A EXG HM - - - 12
018 3'0" 7'0" 1 3/4" A EXG SCWD A EXG HM - - - 12
020 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 T2 20
022 3'0" 7'0" 1 3/4" A SCWD B HM 6 7 11
023 3'0" 7'0" 1 3/4" A SACWD A AHM 3 4 5 STC-50 01
024 3'0" 7'0" 1 3/4" A SACWD A AHM 3 4 5 STC-50 01
025 3'0" 7'0" 1 3/4" A EXG SCWD B EXG HM - - - 12
027 3'0" 7'0" 1 3/4" A SACWD A AHM 3 4 5 STC-50 27
027.1 3'0" 7'0" 1 3/4" A SACWD A AHM 3 4 5 STC-50 33
028 3'0" 7'0" 1 3/4" A SACWD A AHM 3 4 5 STC-50 01
029 3'0" 7'0" 1 3/4" A EXG SCWD A EXG HM - - T2 12
030 3'0" 7'0" 1 3/4" A SCWD B EXG HM - - T2 26
031 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 T2 14
032 3'0" 7'0" 1 3/4" A EXG SCWD A EXG HM - - T2 12
033 3'0" 7'0" 1 3/4" A EXG SCWD A EXG HM - - T2 12
034 3'0" 7'0" 1 3/4" A SACWD A AHM 3 4 5 STC-50 33
035 3'6" 7'0" 1 3/4" D EXG INS MTL A EXG HMI EXG 1" INS - - - 12
037 3'0" 7'0" 1 3/4" A SCWD A EXG HM - - T4 26
038 3'0" 7'0" 1 3/4" C SCWD A HM 7/8" FIRE RESISTIVE 1 2 - 60 MIN 36
100 6'0" 7'0" 1 3/4" B ALUM C ALUM 1" LAM INS 14 12 13 02
100.1 6'0" 7'0" 1 3/4" B ALUM A ALUM 1/4" TEMP 10 11 - 03
101.1 3'6" 8'0" 1/2" E GLASS - - 1/2" TEMP 43 43 28
101.2 3'6" 8'0" 1/2" E GLASS - - 1/2" TEMP 43 43 28
101.3 3'6" 8'0" 1/2" E GLASS - - 1/2" TEMP 43 43 28
102 3'0" 8'0" 1/2" E GLASS - - 1/2" TEMP 43,44 43,44 28
103 3'0" 8'0" 1/2" E GLASS - - 1/2" TEMP 43,44 45,46,47 43,44 28
104 3'0" 8'0" 1/2" E GLASS - - 1/2" TEMP 43,44 45,46,47 43,44 28
105 3'0" 8'0" 1/2" E GLASS - - 1/2" TEMP 43,44 45,46,47 43,44 28
106 3'0" 8'0" 1/2" E GLASS - - 1/2" TEMP 43,44 45,47 43,44 28
107 3'0" 7'0" 1 3/4" A SACWD A AHM 3 4 5 STC-50 31
108 3'0" 7'0" 1 3/4" A SACWD A AHM 59 60 5 STC-50 29
108.1 3'0" 7'0" 1 3/4" A SACWD A AHM 59 60 5 STC-50 29
110A 6'0" 7'0" 1 3/4" A SCWD A HM 1 2 (SIM.) - 23
111A 7'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 23
112A 6'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 22
113 3'0" 7'0" 1 3/4" A SACWD A AHM 3 4 5 STC-45 05
113.1 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 06
114 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 T3 SIM 30
118 3'0" 7'0" 1 3/4" A SCWD A HM 55 56 - 14
119 3'0" 7'0" 1 3/4" A SCWD A HM 57 58 - 14
120 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 T2 20
121 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 T3 15
124 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 T3 21
125 3'0" 7'0" 1 3/4" C SCWD A HM 7/8" FIRE RESISTIVE 1 2 - 60 MIN 32
126 6'0" 7'0" 1 3/4" B ALUM D ALUM 1" LAM INS 17 18 15,16 02
126.1 5'4" 7'0" 1 3/4" B ALUM E ALUM 1/4" TEMP 20 19 - 03 1-3'-0" LEAF, 1-2'-4" LEAF, VIF WIDTH
127 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 T3 15
127.1 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 15
127A 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 19
130 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 T1 17
131 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 T4 14
132 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 T4 10
133 3'0" 7'0" 1 3/4" A SCWD - WOOD 40 41 - 34
133A 3'0" 7'0" 1 3/4" A SCWD B HM 1 53 SIM. - 42
134 3'0" 7'0" 1 3/4" A SCWD A EXG HM - - T3 09
134.1 3'0" 7'0" 1 3/4" A SCWD B HM 6 SIM. 7 SIM. - 20
136 3'0" 7'0" 1 3/4" A SCWD B HM 8 9 - 11
137 8'0" 8'0" 1 3/4" A INS MTL A HMI 37 36 SIM. 34 SIM. 39
138 7'0" 7'0" 1 3/4" A INS MTL B HMI 35 36 34 39
140 4'0" 7'0" 1 3/4" A INS MTL EXG. A EXG HM EXG. EXG. EXG. 24
141 3'0" 7'0" 1 3/4" A INS MTL A HMI 35 SIM 36 34 38
142 3'0" 7'0" 1 3/4" EXG. A EXG SCWD EXG. A EXG HM EXG. EXG. EXG. 12
143 3'0" 7'0" 1 3/4" B SCWD A HM 1/4" TEMP 1 2 T2 14
143A 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 19
144 3'0" 7'0" 1 3/4" B SCWD A HM 1/4" TEMP 1 2 T2 14
146 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 14
147 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 14
148 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 11
149 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 11
152 5'9" 7'0" 1 3/4" B ALUM F ALUM 1" LAM INS 24 25 42 SIM. 02 1-3'-0" LEAF, 1-2'-9" LEAF
152.1 6'0" 7'0" 1 3/4" B ALUM I ALUM 1/4" TEMP 21 22,23 - 03
153 3'0" 7'0" 1 3/4" B ALUM J ALUM 1/4" TEMP, TR FILM 30 22 T3 37 REFER TO INTERIOR ELEVATION FOR TRANSLUCENT FILM LAYOUT
153.1 3'0" 7'0" 1 3/4" B ALUM G ALUM 1" LAM INS 26 28,29 27 13
154 3'0" 7'0" 1 3/4" B SCWD - WOOD 1/4" TEMP, TR FILM 40 41 - 35 REFER TO INTERIOR ELEVATION FOR TRANSLUCENT FILM LAYOUT
155 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 14
156 3'0" 7'0" 1 3/4" A SCWD A HM 1 2 - 11
157 3'0" 8'0" 1/2" E GLASS - - 1/2" TEMP 48,49 50, 46 SIM 48,49 28
158 3'6" 7'0" 1 3/4" D INS MTL A HMI 1" LAM INS 31 32 33, 15 16
159 3'0" 7'0" 1 3/4" B ALUM H ALUM 1" LAM INS 38 39 42 13
159.1 3'0" 7'0" 1 3/4" EXG. C EXG SCWD EXG. C EXG HM EXG. 1/4" WIRE EXG. EXG. EXG. EXG. 60 MIN. 08
SCWD SOLID CORE WOOD (DOOR)
SACWD SOLID ACOUSTIC CORE WOOD (DOOR)
HM HOLLOW METAL (FRAME)
AHM ACOUSTIC HOLLOW METAL (FRAME)
INS MTL INSULATED METAL (DOOR)
HMI HOLLOW METAL, INSULATED (FRAME)
ALUM ALUMINUM (DOOR AND FRAME)
TEMP TEMPERED GLASS
INS INSULATED GLASS
LAM, INS INSULATED GLASS WITH INTERIOR
LAMINATED PANE (BLAST MITIGATION)
TR FILM TRANSLUCENT FILM
STC SOUND TRANSMISSION CLASS
UL UL FIRE RATING
HW SET HARDWARE SET; REFER TO SPEC. SECTION 087100
ABBREVIATIONS FOR DOOR SCHEDULE
(STC-50 WALL SHOWN)
FILL HEAD
SOLID W/
GROUT
COMPRESSION
SOUND SEAL
(STC-50 WALL SHOWN)
FILL JAMB
SOLID W/
GROUT
COMPRESSION
SOUND SEAL
SWING OF DOOR TO
OPEN POSITION
N
ET
D O
O R
H
EI
G H
T
JA
M
P O
PE
N
IN
G
H
EI
G H
T
1/ 4"
1 1/2"
COORDINATE CONDUIT REQUIREMENTS FOR SECURITY
HARDWARE WITH ELECTRICAL DRAWINGS
COORDINATE CONDUIT REQUIREMENTS FOR SECURITY
HARDWARE WITH ELECTRICAL DRAWINGS
GROUT CORE AT JAMB
BLOCK SOLID
4"
SEALANT
GROUT CORE AT JAMB
BLOCK SOLID
DOOR DETAILS
A-7.1
SLOPE 1/8" PER FOOT
6" x 2 1/2", 12 GA. STUDS @ 8" O.C.
EXG. STUD (ASSUMED)
A-7.2
A-7.3
GROUT CORE AT JAMB
BLOCK SOLID
FILL HEAD SOLID
W/ GROUT
COMPRESSION
SOUND SEAL
FILL JAMB SOLID
W/ GROUT
COMPRESSION
SOUND SEAL
COORDINATE CONDUIT
REQUIREMENTS FOR
SECURITY HARDWARE WITH
ELECTRICAL DRAWINGS
COORDINATE CONDUIT
REQUIREMENTS FOR
SECURITY HARDWARE WITH
ELECTRICAL DRAWINGS
DOOR DETAILS
A-7.4
SEE PLAN FOR PARTITION TYPE
SEE PLAN FOR PARTITION TYPE
SEE PLAN FOR PARTITION TYPE
SEE PLAN FOR PARTITION TYPE
FILL HEAD SOLID
W/ GROUT
GROUT CORE AT JAMB
BLOCK SOLID
FILL JAMB SOLID
W/ GROUT
1 1/2" METAL FURRING, PNT
FLAT BLACK
5/8" GWB, FIRE TAPE, PNT
FLAT BLACK
FILL HEAD SOLID
W/ GROUT
COMPRESSION
SOUND SEAL
FILL JAMB SOLID
W/ GROUT
COMPRESSION
SOUND SEAL
COORDINATE CONDUIT REQUIREMENTS FOR SECURITY
HARDWARE WITH ELECTRICAL DRAWINGS
COORDINATE CONDUIT REQUIREMENTS FOR SECURITY
HARDWARE WITH ELECTRICAL DRAWINGS
| A-7.0-Door Schedule, Elevations, and Details |
| Viewport-12 |
| Viewport-3 |
| schedule |
| Viewport-13 |
| Viewport-5 |
| 1/A-7.0 |
| 1/A-7.2 |
| Viewport-7 |
| Viewport-9 |
| A-7.1-Door Schedule, Elevations, and Details |
| 1/A-7.1 |
| 1/A-7.4 |
| 1/A-7.5 |
| 1/A-7.7 |
| 1/A-7.6 |
| 1/A-7.9 |
| 1/A-7.11 |
| 1/A-7.12 |
| 1/A-7.13 |
| 1/A-7.15 |
| 1/A-7.17 |
| 1/A-7.26 |
| A-7.2-Door Schedule, Elevations, and Details |
| 1/A-7.16 |
| 1/A-7.18 |
| 1/A-7.19 |
| 1/A-7.21 |
| 1/A-7.22 |
| 1/A-7.24 |
| 1/A-7.25 |
| 1/A-7.27 |
| 1/A-7.23 |
| 1/A-7.28 |
| 1/A-7.30 |
| 1/A-7.29 |
| 1/A-7.32 |
| 1/A-7.34 |
| 1/A-7.31 |
| 1/A-7.33 |
| A-7.3-Door Schedule, Elevations, and Details |
| 1/A-7.46 |
| 1/A-7.36 |
| 1/A-7.38 |
| 1/A-7.40 |
| 1/A-7.39 |
| 1/A-7.42 |
| 1/A-7.43 |
| 1/A-7.44 |
| 1/A-7.48 |
| 1/A-7.49 |
| 1/A-7.51 |
| 1/A-7.53 |
| 1/A-7.54 |
| Viewport-6 |
| Viewport-10 |
| Viewport-14 |
| Viewport-16 |
| A-7.4-Door Schedule, Elevations, and Details |
| 1/A-7.8 |
| Viewport-8 |
| Viewport-15 |
| Viewport-18 |
| Viewport-20 |
| Viewport-21 |
| Viewport-23 |
| Viewport-17 |
| Viewport-22 |
| 1/A-7.14 |
| 1/A-7.35 |
| Viewport-11 |
| Viewport-24 |
| 3/A-7.0 |
| 3/A-7.2 |
| 3/A-7.4 |
| 3/A-7.6 |
File details come from the government source that posted it. Updated .