0705-CD B3 F-35 Cover-ALIS.pdf

PDF 3 MB Posted

Attached to
F-35 ALTER BUILDING 140 SQUAD OPS FACILITY Federal contract opportunity
Solicitation number
W912LN-17-B-1000
Issued by
Department of the Army Vermont Army National Guard

About this file

F35 Cover ALIS

View the file

Other files for this federal contract opportunity

Other files attached to F-35 ALTER BUILDING 140 SQUAD OPS FACILITY, newest first.
File Type Posted
W912LN-17-C-1000.pdf PDF
W912LN-17-B-1000_Amendment_0001.pdf PDF
Attachment_2_-_16V01ME_E1.11-SKE-2.pdf PDF
Attachment_3_-_Roof_Warranty.pdf PDF
Attachment_1_-_16V01ME_E1.10-SKE-1.pdf PDF
Pre_Proposal_Minutes.pdf PDF
B-140_Pre-Bid.pptx PPTX presentation
B140_Site_Visit_Attendance_Roster.pdf PDF
0705 - B-3 Project Manual 021017.pdf PDF
21-S1.0 - B140.pdf PDF
03-0705-XC Floor Plans.pdf PDF
0705-CD B3 F-35 Plan-ALIS.pdf PDF
10-0705-CD B3 Wall Types.pdf PDF
13-0705-CD B3 Stairs.pdf PDF
31-16V01ME Plumbing B-3 Submission 20170209.pdf PDF
16V01ME-ALIS Electrical B3 Submission 20170208.pdf PDF
18-0705-CD B3 Windows.pdf PDF
B140_Squad_OPS.zip ZIP file
05-0705-XC Sections.pdf PDF
06-0705-CD B3 Site Plan.pdf PDF
20-0705-CD B3 Interior Details.pdf PDF
09-0705-CD B3 Roof Details.pdf PDF
02-Civil Plans B140 2-10-2017.pdf PDF
0705-Project Manual 021017 F35.pdf PDF
14-0705-CD B3 Int elev A-6-0-6.pdf PDF
32-16V01ME Fire Protection B3 Submission 20170208.pdf PDF
27-S3.2 - B140.pdf PDF
16112ME- ALIS Mechanical B3 Submission 20170209.pdf PDF
17B1000_11_May_17.pdf PDF
29-16V01ME Mechanical B3 Submission 20170209.pdf PDF
17-0705-CD B3 Doors.pdf PDF
16112ME Lighting Photometrics.pdf PDF
19-0705-CD B3 Exterior Details.pdf PDF
30-16V01ME Electrical B3 Submission 20170209.pdf PDF
24-S2.1 - B140.pdf PDF
04-0705-XC Exterior Elevations.pdf PDF
15-0705-CD B3 Int elev A-6-7-13.pdf PDF
12-0705-CD B3 Sections.pdf PDF
23-S1.2 - B140.pdf PDF
11-0705-CD B3 Ext Elev.pdf PDF
22-S1.1 - B140.pdf PDF
25-S2.2- B140.pdf PDF
07-0705-CD B3 Plans.pdf PDF
08-0705-CD B3 Roof Plan.pdf PDF
16-0705-CD B3 Int elev A-6-14-18.pdf PDF
26-S3.1 - B140.pdf PDF
Civil Plans B140 2-10-2017.pdf PDF
28-S3.3 - B140.pdf PDF
01-0705-CD B3 Alter B-140 Cover.pdf PDF
Show all 49

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

INTERNATIONAL BUILDING CODE - IBC-2012

USE & OCCUPANCY CLASSIFICATION: MIXED USE, NON-SEPARATED.

ASSEMBLY (A-3)/ BUSINESS (B)

EXISTING BUILDING HEIGHT & AREA:

• TWO STORY BUILDING PLUS A BASEMENT

• TOTAL GROSS BUILDING AREA: 32,991 SF

• GROSS AREA OF MAIN STORY: 18,131 SF

• BUILDING HEIGHT, MAIN BLDG: 27 FT

TOWER HEIGHT: 70 FT

• CONSTRUCTION TYPE: 2B

• ALLOWABLE HEIGHT/AREA: A-3 / 2B CONSTRUCTION:

2 STORIES / 55 FT / 9,500 SF PER STORY (MOST RESTRICTIVE)

• ALLOWABLE AREA W/ SPRINKLER INCREASE:

9,500 SF x 200% = 19,000 SF

9,500 SF + 19,000 SF = 28,500 SF PER STORY

[THE BUILDING MEETS THE HEIGHT AND AREA LIMITATIONS FOR AN

ASSEMBLY/TYPE 2B BUILDING AND THEREFORE, THE MODIFICATION FOR

FRONTAGE INCREASE WAS NOT ASSESSED.]

F-35 ALTER B-140

SQUAD OPS ALIS

CURZ 151807

NFPA 101, LIFE SAFETY CODE- 2012 EDITION

CLASSIFICATION OF OCCUPANCY: MIXED OCCUPANCY,

EXISTING ASSEMBLY & EXISTING BUSINESS

• ANTICIPATED OCCUPANCY:

• AVERAGE DAILY: 64 PEOPLE

• MAXIMUM: 206 PEOPLE

NUMBER OF MEANS OF EGRESS:

NOT LESS THAN (2) MEANS OF EGRESS SHALL BE PROVIDED

FROM EVERY STORY OR SECTION OF THE FACILITY.

ARRANGEMENT OF MEANS OF EGRESS:

ASSEMBLY (MOST RESTRICTIVE)

• COMMON PATH OF TRAVEL: 20 FT / 75 FT < 50

• DEAD-END CORRIDOR LIMIT: 20 FT

• MAXIMUM TRAVEL DISTANCE: 250 FT

CORRIDORS ARE NOT REQUIRED TO HAVE A FIRE RATING

WHEN BUILDING IS SPRINKLERED.

INTERNATIONAL BUILDING CODE - IBC-2012

NFPA 101, LIFE SAFETY CODE, 2012 EDITION

2010 ADA STANDARDS FOR ACCESSIBLE DESIGN