07212.doc
DOC document 35 KB Posted
- Solicitation number
- W912L2-09-R-5001
About this file
Div 7
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 01400.doc | DOC document | |
| 16010.doc | DOC document | |
| A2.pdf | ||
| 10500.doc | DOC document | |
| 02741.RTF | RTF text file | |
| 02743.doc | DOC document | |
| 01800.doc | DOC document | |
| 09250.doc | DOC document | |
| M3.pdf | ||
| 10522.DOC | DOC document | |
| 01200.doc | DOC document | |
| M2.pdf | ||
| M1.pdf | ||
| 09006 15100.pdf | ||
| 07900.doc | DOC document | |
| 10425.doc | DOC document | |
| 08111.DOC | DOC document | |
| 09512.doc | DOC document | |
| 06402.doc | DOC document | |
| D1.pdf | ||
| 01040.doc | DOC document | |
| 04200.doc | DOC document | |
| 09225.doc | DOC document | |
| 10800.DOC | DOC document | |
| A7.pdf | ||
| 02223.doc | DOC document | |
| 07600.DOC | DOC document | |
| A5.pdf | ||
| S2.pdf | ||
| 09200.DOC | DOC document | |
| Form 1354 JULY_2003 R1.pdf | ||
| A1.pdf | ||
| 07215.doc | DOC document | |
| TOC_B-3.doc | DOC document | |
| 03300.doc | DOC document | |
| 09006 15300.pdf | ||
| 16050.doc | DOC document | |
| 07510.doc | DOC document | |
| A6.pdf | ||
| P3.pdf | ||
| E1.pdf | ||
| C1.pdf | ||
| 02742.doc | DOC document | |
| 01560.doc | DOC document | |
| A4.pdf | ||
| 03210.doc | DOC document | |
| A3.pdf | ||
| 09660.DOC | DOC document | |
| A8.pdf | ||
| 08710.DOC | DOC document |
Show 40 more
Latest 50 of 78 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION 07212
| DIVISION 7 |
| FACED BATT INSULATION |
PART 1
GENERAL
1.1
SUMMARY
A.
Includes But Not Limited To
1.
Furnish and install thermal batt insulation as described in Contract Documents.
1.2
REFERENCES
A.
American Society For Testing And Materials
1.
ASTM C 665-96, 'Standard Specification for Mineral-Fiber Thermal Insulation For Light Frame Construction and Manufactured Housing'
PART 2
PRODUCTS
2.1
MATERIALS
A.
Insulation
1.
FRK faced meeting requirements of ASTM C 665, Type II, Class C.
2.
Order insulation by 'R' factor rather than 'U' factor, rating, or thickness, either 16 or 24 inches wide according to framing spacing.
3.
'R' Factor Required -a.
Ceilings - 30
4.
Acceptable Manufacturers -a.
Certainteed Corp, Valley Forge, PA (800) 523-7844 b.
Owens-Corning Fiberglass Corporation, Toledo, OH (800) 832-3585 c.
Johns-Manville, Denver, CO West (800) 622-0149 East (800) 368-4430 d.
Thermafiber by United States Gypsum Co, Chicago, IL (800) 874-4968
2.2
SOURCE QUALITY CONTROL
A. Insulation shall be manufactured to be in compliance with UBC or other applicable building codes.
PART 3
EXECUTION
3.1
INSTALLATION
A. Install in accordance with Manufacturer's directions, in compliance with UBC or other applicable building codes, and as follows
1.
If two layers of insulation are used to attain required 'R' factor, only layer towards interior of building shall have facing.
2.
Leave no gaps in insulation envelope.
3.
Install insulation between jambs & framing, behind plumbing & wiring and in similar places.
4.
Fit ends of batts snug against top and bottom plates.
5.
Where insulation is not enclosed by structure or drywall, support in place with wire or other suitable material and use only foil faced insulation.
6.
Install baffles between trusses and rafters at ventilation spaces if necessary to prevent insulation from blocking air flow from soffit.
7.
Do not cover recessed light fixtures with insulation. Cut out insulation to provide a minimum of 6-inch clearance around recessed lighting fixtures.
END OF SECTION