ELLINGTON FIELD - HOUSTON, TEXAS
REPLACE FIRE STATION
TEXAS AIR NATIONAL GUARD
J SEIBERT
ELECTRICAL
LEGEND AND ABBREVIATIONS
E-001
A
A
A
E
P
D
SV
LS
T
PE
PS
PC
G
R
C
8M-20
3-25
W
60/2
EMH
S
S
R
B
S
FLUORESCENT LIGHTING FIXTURE,
FLUORESCENT ONE BY FOUR LIGHTING FIXTURE,
STRIP FLUORESCENT LIGHTING FIXTURE,
EMERGENCY LIGHTING, SELF CONTAINED
TRACK LIGHTING
EMERGENCY LIGHTING REMOTE HEAD
EXIT LIGHT WITH ARROW, LETTER DENOTES TYPE
CONDUIT CONCEALED IN WALL OR CEILING
TIC MARKS INDICATE NUMBER OF WIRES.
FROM LEFT TO RIGHT: SWITCH LEG, PHASES,
NEUTRAL AND GROUND
CONDUIT, EXPOSED
J
J
JUNCTION BOX, SURFACE MOUNTED
JUNCTION BOX, WALL MOUNTED FLUSH
PULL BOX
CONDUIT WITH INSULATED BUSHING
CONDUIT SEAL OFF
FIRE ALARM CONTROL PANEL (FACP)
FIRE ALARM ANNUNCIATOR PANEL (FAA)
FIRE ALARM MANUAL STATION
FIRE ALARM HORN/STROBE LIGHT
FIRE ALARM BELL
FIRE ALARM STROBE LIGHT
HEAT DETECTOR
ULTRAVIOLET DETECTOR
DUCT MOUNTED SMOKE DETECTOR
F - FIXED TEMPERATURE
R - RATE OF RISE
RF - COMBINATION RATE OF RISE
AND FIXED TEMPERATURE
FLOW SWITCH
TAMPER SWITCH
DOOR HOLDER
SOLENOID VALVE CONNECTION
LIMIT SWITCH CONNECTION
THERMOSTAT CONNECTION
PNEUMATIC/ELECTRIC CONNECTION
PRESSURE SWITCH CONNECTION
PHOTOCELL
QUADRAPLEX RECEPTACLE
SPECIAL PURPOSE RECEPTACLE WITH
NEMA DESIGNATION
6-60
MULTI-OUTLET SURFACE RACEWAY, SIZE AND
NUMBER OF RECEPTACLES AS SCHEDULED.
NUMBER INDICATES CIRCUIT.
3 - 3 WAY
2 - DOUBLE POLE
WALL SWITCH 120-277 VOLT, 20 AMP, SINGLE POLE
SUBSCRIPT DENOTES THE FOLLOWING:
HP - MOTOR RATED SWITCH
4 - 4 WAY
K - KEY OPERATED
L - LOW VOLTAGE
M - MOTION DETECTOR
P - PILOT LIGHT
5 MOTOR CONNECTION (5 HP INDICATED)
PANELBOARD, SURFACE MOUNTED
PANELBOARD, RECESSED
SWITCHBOARD
T
TRANSFORMER
DISCONNECT SWITCH
FUSE SIZE, UL CLASS
SWITCH AMP RATING
NUMBER OF POLES
ENCLOSED CIRCUIT BREAKER
NUMBER OF POLES
TRIP RATING (AMPS)
MOTOR CONTROLLER
1 INDICATES STARTER NEMA SIZE
3 INDICATES NUMBER OF POLES
NOTATION WHEN OTHER THAN ACROSS THE LINE
RVA - REDUCED VOLTAGE AUTO TRANSFORMER
RVR - REDUCED VOLTAGE PRIMARY RESISTOR
RVP - REDUCED VOLTAGE PART WINDING
RVW - REDUCED VOLTAGE Y/DELTA
R - REVERSIBLE
COMBINATION STARTER
NUMBER OF POLES
SWITCH AMP RATING
FUSE SIZE, UL CLASS
STARTER NEMA SIZE
WIREWAY
CABLE TRAY
PLUG IN OR FEEDER BUS
FLOOR GROUNDING PLATE
WALL MOUNTED SINGLE FACE CLOCK
EMERGENCY POWER OFF PUSHBUTTON STATION,
CONTACTOR
RELAY CONTROL UNIT
PUSHBUTTON STATION, 1, 2, 3 BUTTONS
RED MUSHROOM HEAD
GENERATOR SET
AUTOMATIC TRANSFER SWITCH
D - DOUBLE FACE CLOCK
POLE, LENGTH AND CLASS AS INDICATED
POLE MOUNTED LIGHT FIXTURE
T
DOWN GUY-NOTED AS 8000 POUND STRENGTH,
TRANSFORMER BANK POLE MOUNTED,
SINGLE PHASE TRANSFORMER, POLE MOUNTED
PAD MOUNTED TRANSFORMER,
DISCONNECT SWITCH, GANG OPERATED
AUTOMATIC CIRCUIT RECLOSURE
GROUND ROD
LIGHTNING ROD, SHOWN AS 24" HIGH
MAST TYPE LIGHTNING PROTECTION SYSTEM,
LIGHTNING ROD ON POLE FOR SEPARATELY
MANHOLE
ANCHOR AT 20 FEET FROM POLE
SHOWN AS 3 PHASE, 25kVA
SHOWN AS 25kVA
SHOWN AS 100kVA
SHOWN AS 60’ CLASS, 2 POLE
EMH - ELECTRICAL, TMH - TELEPHONE
CMH - COMMUNICATIONS
OVERHEAD PRIMARY, SHOWN AS 4-#6
OHP
4160V4-#6
CONDUCTORS, 4160 V
UNDERGROUND PRIMARY
UP
OVERHEAD SECONDARY
OS
UNDERGROUND SECONDARY
US
UNDERGROUND TELEPHONE CONDUIT
UT
OVERHEAD TELEPHONE
OT
UNDERGROUND COMMUNICATION
UC
UNDERGROUND FIBER OPTIC
UF
BURIED GROUND WIRE
BG
GROUND WIRE EXPOSED
G
ROOF CONDUCTOR
G
GROUND CONNECTION OR EQUIPMENT BOND
INTERCOMMUNICATIONS STATION
M
SPEAKER, WALL MOUNTED
SPEAKER, CEILING MOUNTED
FIXED CAMERA
PAN/TILT/ZOOM CAMERA
MOTION DETECTOR
GLASS BREAK DEVICE
KEY PAD
CARD READERCR
KP
ES
AMP
AL
AHU
BLDG
CKT
C
CONN
COND
CU
DET
DN
DISC
DP
EA
ELEC
EM
EMT
EP
F
FLA
FLEX
FLR
FLUOR
GND
GALV
GFI
HID
HP
H
IG
IN
IMT
JB
KCM
KVA
KVAR
KW
KWH
LA
LTG
LV
MAX
MCB
MCC
MDF
MFG
MG
MH
MIC
MIN
MLO
MTD
N/A
NEC
NEMA
NFPA
NIC
NTS
NO
PB
PH
PNL
POC
PS
QTY
RCPT
SCH
SQ FT
SW
SYS
TEL
TYP
UH
UPS
V
W
W/
W/O
WP
WT
REF
XFMR
WITH
WEIGHT
TRANSFORMER
REFERENCE, REFER
WEATHERPROOF
WITHOUT
SCHEDULE
SQUARE FOOT
TYPICAL
VOLTAGE
WIRE
UNINTERRUPTABLE POWER SUPPLY
UNIT HEATER
TELEPHONE
SYSTEM
SWITCH
QUANTITY
RECEPTACLE
PULL SWITCH
POINT OF CONNECTION
PULL BOX, PUSH BUTTON
PANEL
PHASE
NORMALLY OPEN, NUMBER
NOT TO SCALE
MOTOR GENERATOR
NATIONAL ELECTRIC MANUFACTURERS ASSOCIATION
MOUNTED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATIONAL ELECTRIC CODE
NOT APPLICABLE
MAIN LUGS ONLY
MINIMUM
MICROPHONE
MANHOLE, METAL HALIDE, MOUNTING HEIGHT
MOTOR CONTROL CENTER
MANUFACTURER
MAIN DISTRIBUTION FRAME
MAIN CIRCUIT BREAKER
MAXIMUM
LIGHTNING ARRESTOR
LOW VOLTAGE
LIGHTING
KILOWATT HOUR
KILOWATT
GROUND FAULT INTERRUPT
1000 CIRCULAR MILS
INCH
KILOVOLT AMPS REACTIVE
KILOVOLT AMPS
JUNCTION BOX
INTERMEDIATE METAL CONDUIT
ISOLATED GROUND
HEIGHT
HORSE POWER
HIGH INTENSITY DISCHARGE
FLUORESCENT
GALVANIZED
GROUND
FLOOR
FLEXIBLE
EXPLOSIONPROOF
FULL LOAD AMPS
FUSE
ELECTRICAL METALLIC TUBING
CONDUIT
CONDUCTOR
CONNECTION
DOWN
EACH
EMERGENCY
ELECTRICAL
DISTRIBUTION PANEL
DISCONNECT
DETAIL
COPPER
AIR HANDLING UNIT
CIRCUIT
BUILDING
ALUMINUM
AMPERES
NOTE CALL OUT
NORTH ARROW
MOUNTED LIGHTNING PROTECTION SYSTEM
MECH MECHANICAL
BATTERY PACK.
COMMUNICATION BACKBOARD
E - DENOTES EMERGENCY BATTERY PACK
DUAL SWITCHED LIGHTING FIXTURE,
WP
WP - WEATHERPROOF
EP - EXPLOSION PROOF
GFI - GROUND FAULT INTERUPT
IG - ISOLATED GROUND
ACT - ABOVE COUNTER TOP
D - DEDICATED
C - CLEAN POWER
E - EMERGENCY
D - DIMMER
POTENTIAL TRANSFORMER
SURGE SUPPRESSOR
CONTACT NORMAL OPEN
CONTACT NORMAL CLOSED
FUSE
GROUND
TRANSFORMER
DRAW OUT CIRCUIT BREAKER
CIRCUIT BREAKER
DRAW OUT FUSE
RELAY
CURRENT TRANSFORMER
DISCONNECT SWITCH
DISCONNECT SWITCH WITH FUSE
LIGHTNING ARRESTOR
P - POWER
C - CEILING
D - DATA
T - TELEPHONE
H - HUB
VARIABLE FREQUENCY CONTROLLER
CONTROLLER TYPE
C - CONSTANT TORQUE
H - CONSTANT HP
HP RATING
NUMBER OF POLES
TVSS TRANSIENT VOLTAGE SUPPRESSION SYSTEM
IAW IN ACCORDANCE WITH
M MOTORIZED DAMPER
S - SUPPLY
R - RETURN
REMOTE TEST UNITRTU
NL - DENOTES NIGHT LIGHT
b a a - DENOTES SWITCH DESIGNATION b - DENOTES SWITCH DESIGNATION
SECTION CUT
INDICATES DIRECTION SECTION IS TAKEN
SECTION IDENTIFICATION NUMBER
3/1/R
AUTOMATIC TRANSFER SWITCH
MDP MAIN DISTRIBUTION PANEL
IDF INTERMEDIATE DISTRIBUTION FRAME
D
G
PVC POLYVINYL CHLORIDE
RGS RIGID GALVANIZED STEEL
EWC ELECTRICAL WATER COOLER
ENT ELECTRICAL NON-METALLIC TUBING
INC INCANDESCENT
A
A
FAA
FA
AFG ABOVE FINISHED GRADE
AFF ABOVE FINISHED FLOOR
CONDUIT UP
CONDUIT DOWN
ACT ABOVE COUNTER TOP
MOTION SENSORS
DOOR BELL
DOOR CHIME
UON UNLESS OTHERWISE NOTED
FC - FAN SPEED CONTROL
SINGLE RECEPTACLE
TV - TELEVISION
NOT NECESSARILY ALL APPEAR
SHEET ARE STANDARD AND MAY
ABBREVIATIONS SHOWN ON THIS
THE SYMBOLS, NOTES, AND
ON THIS PROJECT.
P
30/3
3/1
3/15/C
INTERIOR CONDUIT AND WIRE
FIRE ALARM DEVICES
INTERIOR POWER EQUIPMENT AND DEVICES
COMMUNICATION
MISCELLANEOUS
ONE-LINE
SPECIAL DEVICES ABBREVIATIONS
A - DENOTES TYPE, SEE SCHEDULE
BP - BLANK PLATE
w
ELECTRIC STRIKE
ML MAGNETIC LOCK
V SPEAKER VOLUME CONTROL
FLOOR OUTLET
AFI- ARC FAULT INTERRUPTER
DC DOOR CONTACT
3/1
NEMA RATING
PC - PULL CHAINPC
M
M
M- MASS NOTIFICATION
F
F
F
F
H
S
SS
TS
FS
U
D
DETAIL
1"=1"
E-101
NUMBER OF SHEET ON WHICH SECTION
IS DRAWN
DETAIL
A
FLUORESCENT LIGHTING FIXTURE,
WITH EMERGENCY BALLASTA
A
X1 X2
A
A
N
S
POINT OF CONNECTION
CL- CEILING MOUNTED
CABLE TELEVISION OUTLET
18" AFF- UNLESS NOTED OTHERWISE
DUPLEX RECEPTACLE- 18" AFF-
UNLESS NOTED OTHERWISE
I IONIZATION SMOKE DETECTOR
FLOOR MOUNTED
DOOR OPERATING SIGNAL LIGHT
LIGHTING FIXTURE- CEILING
LIGHTING FIXTURE- WALL MOUNTED
EMERGENCY LIGHTING FIXTURE- CEILING
EMERGENCY LIGHTING FIXTURE- WALL MOUNTED
EXTERIOR
R REQUEST TO EXIT PUSHBUTTONS
GB
LIGHTING
M
S
G GOLDSMITH
INTERFACE DEVICE
CARBON MONOXIDE DETECTOR
FR
CO
M- MASS NOTIFICATION
DS DAYLIGHT SENSOR
SMOKE/HEAT COMBINATION DETECTOR- SINGLE STATION
SMOKE/HEAT COMBINATION DETECTOR
COP CARBON MONOXIDE CONTROL PANEL
FWJH059032
M MASS NOTIFICATION STROBE LIGHT
AH PHILLIPS
TELECOMMUNICATION OUTLET, MOUNT AT 18" AFF
TO CENTER OF BOX. (4) 4 PAIR UTP CATEGORY 6 CABLES,
UNLESS OTHERWISE NOTED. 1" CONDUIT STUBBED TO
NEAREST CABLE TRAY.
TELEPHONE OUTLET (1) PAIR UTP
CATEGORY 6 CABLE, 3/4" CONDUIT.
JUNE 2008
S c a l e
F o r
M i c r o f i l m i n g
I n c h e s
M i l l i m e t e r s
no. date revisionby
191 1615141312111098765432 17 18
N
M
L
K
J
I
H
G
F
E
D
C
B
A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
FILENAME: PLOT DATE: PLOT TIME:dn10e001_339673.dgn 6/30/2008 6:35:50 PM
3001 PGA BOULEVARD - SUITE 300
PALM BEACH GARDENS, FLORIDA
(561) 904-7400 (561) 904-7401 (FAX)
EB0000072 AAC001992 LC26000188
FINAL SUBMITTAL
JUNE 27, 2008
XX
CB
CB
CBCBCB
CBCBSCB
CO
S
S c a l e
F o r
M i c r o f i l m i n g
I n c h e s
M i l l i m e t e r s
no. date revisionby
191 1615141312111098765432 17 18
N
M
L
K
J
I
H
G
F
E
D
C
B
A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
FILENAME: PLOT DATE: PLOT TIME:dn10e100_339673.dgn 6/30/2008 6:36:53 PM
3001 PGA BOULEVARD - SUITE 300
PALM BEACH GARDENS, FLORIDA
(561) 904-7400 (561) 904-7401 (FAX)
EB0000072 AAC001992 LC26000188
FINAL SUBMITTAL
JUNE 27, 2008
ELLINGTON FIELD - HOUSTON, TEXAS
REPLACE FIRE STATION
TEXAS AIR NATIONAL GUARD
J SEIBERT
ELECTRICAL
SITE PLAN
E-100
ELECTRICAL SITE PLAN
1"=30’
N
ELECT RM
PAD MOUNTED
TRANSFORMER
UNDERGROUND
PRIMARY
UNDERGROUND
SECONDARY
0 30 60 90
1"=30’-0"
G GOLDSMITH
E-501
CIRCUIT
H1-10
E-501
E-501
EMERGENCY GENERATOR
NOTES:
1. REFER TO DWG E-601 FOR CONDUIT AND
CONDUCTOR SIZES.
POWER POLE #7
COMM MANHOLE
NEW COMM/PHONE
MANHOLE
2- 4"C
1 WITH MAXCELL
INTERDUCT
4- 4"C
2 WITH MAXCELL
INTERDUCT
E-507
E-507
E-507
E-507
E-507
COMM RM
ANTENNA
4"C TO COMM ROOM
WITH MAXCELL INTERDUCT
4"C TO ALARM
CONTROL ROOM
WITH MAXCELL
INTERDUCT
E-501
TYP
SA
SA
SA
SA
SA
SA
CIRCUIT
H1-18
E-501
E -5
2- 4"C
1 WITH MAXCELL
INTERDUCT
E -5
EXISTING TEL
BOX (COPPER)
EXISTING COMM
MANHOLE
(COVER MARKED
SEWER)
FWJH059032
4-4"C
WITH (3) 2" MAXCELL
INNER DUCTS
UNDERGROUND
FROM GENERATOR
TO BUILDING
AH PHILLIPS
TS
PIV FA TAMPER SWITCH
JUNE 2008
ELLINGTON FIELD - HOUSTON, TEXAS
REPLACE FIRE STATION
TEXAS AIR NATIONAL GUARD
J SEIBERT
ELECTRICAL
E-101
1"=30’
N
G GOLDSMITH
PHOTOMETRIC SITE PLAN
0 30 60 90
1"=30’
FWJH059032
ELECTRICAL SITE PHOTOMETRIC PLAN
1"=30’
NELECTRICAL SITE SOLAR PHOTOMETRIC PLAN
ALTERNATIVE BID ITEM #2 BASE BID
JUNE 2008
AH PHILLIPS
S c a l e
F o r
M i c r o f i l m i n g
I n c h e s
M i l l i m e t e r s
no. date revisionby
191 1615141312111098765432 17 18
N
M
L
K
J
I
H
G
F
E
D
C
B
A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
FILENAME: PLOT DATE: PLOT TIME:dn10e101_339673.dgn 6/30/2008 6:37:44 PM
3001 PGA BOULEVARD - SUITE 300
PALM BEACH GARDENS, FLORIDA
(561) 904-7400 (561) 904-7401 (FAX)
EB0000072 AAC001992 LC26000188
FINAL SUBMITTAL
JUNE 27, 2008
XX
CB
CB
CBCBCB
CBCBSCB
CO
S
S c a l e
F o r
M i c r o f i l m i n g
I n c h e s
M i l l i m e t e r s
no. date revisionby
191 1615141312111098765432 17 18
N
M
L
K
J
I
H
G
F
E
D
C
B
A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
FILENAME: PLOT DATE: PLOT TIME:dn10e102_339673.dgn 7/1/2008 2:38:53 PM
3001 PGA BOULEVARD - SUITE 300
PALM BEACH GARDENS, FLORIDA
(561) 904-7400 (561) 904-7401 (FAX)
EB0000072 AAC001992 LC26000188
FINAL SUBMITTAL
JUNE 27, 2008
ELLINGTON FIELD - HOUSTON, TEXAS
REPLACE FIRE STATION
TEXAS AIR NATIONAL GUARD
J SEIBERT
ELECTRICAL
E-102
1"=30’
N
ELECT RM
0 30 60 90
1"=30’-0"
SITE LIGHTING PLAN
SA
SA
SA
SA
E-501
E-501
SB
SA
SB
SA SD
SB
SD
E-501
ALTERNATE BID OPTION #2
ELECTRICAL SITE SOLAR LIGHTING PLAN
FWJH059032
AH PHILLIPS
WD
CONF.
DEPT.
WORK
CERT.
CHIEF
ALARM
AGENT
MEN’S
ROOM
CHIEF
CHIEF
ROOM
VEST
LOBBY
OFF.
TECH SERV
CORR
DINING
PROTECTIVE
CLOTHING
PHYSICAL
FITNESS
FIRE EXT
ROOM
CNTL. RM
TOILET
COMM
COMP
CORR
MECH
ELECT
SCBA
BUNK RM BUNK RM
122 123
BUNK RM BUNK RM
146 147
BUNK RM BUNK RM
BUNK RM
125 126
BUNK RM BUNK RM
127 143
BUNK RM BUNK RM
144 145
BUNK RM
LAUNDRY
INFECTIOUS
CONTROL
118114
CORR
TLT
JAN
CORR
CORR
BAYS
CORR
COVERED ENTRY
OUTDOOR EATING AREA
ROOM
VEST
114A
BATHROOM
BATHROOM
KITCHEN
ASSIST.
OFFICE
OFFICE
TRAINING
TRAINING
AUDIO VISUAL
STORAGE
COMPUTER
SIMULATION
LOCKER
ROOM
(AFFF)
STORAGE
HOSE
STORAGE
APPARATUS
136A
WOMEN’S
BREAK ROOM
S c a l e
F o r
M i c r o f i l m i n g
I n c h e s
M i l l i m e t e r s
no. date revisionby
191 1615141312111098765432 17 18
N
M
L
K
J
I
H
G
F
E
D
C
B
A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
FILENAME: PLOT DATE: PLOT TIME:dn10e110_339673.dgn 6/30/2008 6:39:47 PM
3001 PGA BOULEVARD - SUITE 300
PALM BEACH GARDENS, FLORIDA
(561) 904-7400 (561) 904-7401 (FAX)
EB0000072 AAC001992 LC26000188
FINAL SUBMITTAL
JUNE 27, 2008
D DD
D
L
J
D D D D D D D
D D D D D D D DDD
D
D
D
D
D
D
D
D
D
D
D
D D D D
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
LL
L L
D
D
K
K
K
K
K
K
L
L
L
J J J J J
JJJJJJ
F
F
F F
F
D
D
D
L L
LL
LL
D
D
D
D
D
D
D
D
D
D
L L
L
L
G G G
G G GH
H
H
H
G G
H
H
N
H
H
Y2
Y2 Y2 Y2
Y2 Y2
LL
LL
LL
LL
L
L LLL
C
C
D
C
C
C
Y1 Y1
Y1
Y1
Y1Y1
Y1Y1
Y1
Y
A
A
B
B
M M M M M
M M M M M
M
M
A
A
R
R
R
N
Y1
C
D
Y1
D
D D
DD
D
D D
D D
D
B
B
S
DS S
SDS
DS
SS
DS
DS
SDS
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S S
S S
N
R
R
H
H
D
D
D
D
D D
D
D1 D1
D1D1
A1
A1
A1 A1
A1A1
B1 B1
B1 B1
A1
A1 A1 A1
A1A1
A1A1 A1
A1 A1 A1 A1
A1A1A1A1
D1 D1
D1
D1D1D1
D1
D1
D1 D1
D1
D1
D1
D1 D1 D1
D1D1
D1 D1 D1
D1 D1
D1D1D1
D1
D1
D1
D1
D1
D1
D1
D1
D1D1
D1
D1D1 D1
D1 D1
A1 A1
A1A1
DS
D1 D1
D2 D2
S
S
S
S
H
DSDS DS
DSDSDS
J
J
J
JJ
ELLINGTON FIELD - HOUSTON, TEXAS
TEXAS AIR NATIONAL GUARD
REPLACE FIRE STATION
ELECTRICAL FLOOR PLAN - LIGHTING
1/8"=1’-0"
N
ELLINGTON FIELD - HOUSTON, TEXAS
REPLACE FIRE STATION
TEXAS AIR NATIONAL GUARD
J SEIBERT
ELECTRICAL
LIGHTING PLAN
E-110
S S
S
S
S
S
S
S
S
S S
S
S
S
S
S3D
D
S
S S S S S
S S S S S
S S
S
S
S
S
S S
S
S
S
D S
S
S
S
S
S
S
S
S
S
S
S
S3
S a c b c a c b c a c b c a
X1
X1
X1
X1
X1
X1
X1
X1
X1
X1
X1
S
D S
D S
D S
S
S
X1
X1 b a b a b a b a b a b a b a b a b ab a b a b a b a b a b a
S3
S
6 6 6 6
3 3
3 3
3 3
9 9 9 3 3 3
7 7
7 9
9 9
11 11
11 11
11 11
11 11
111111
11 11
9 9
11 11
7 7
7 7
1 1 1
1 1 1
1 1 1 1
1 1 1
1 1 1
1 1 1
9 9 9 9
1 1 1
11 11
11111111
7 7
9 9 9 9 9 9 9
3 3
3 3 3
3 3 3
3 3
3 3 3 3
9 9
9 9
3 3 3
3 3 3
NOTES:
1.
X1
X1
ALL LIGHTS ARE CIRCUITED TO PANEL "H1"
UNLESS OTHERWISE NOTED. PANEL ’H1’
LOCATED IN ELECT. RM.
UNLESS OTHEREWISE NOTED MOTION SENSORS
AND SWITCHES SHALL CONTROL LIGHTS WITHIN
ENCLOSED SPACE IN WHICH IT IS LOCATED.
PROVIDE ALL NECESSARY CONTROL WIRING
FOR MOTION SENSORS.
PLACE ALL LIGHT SWITCHES ON THE STRIKE
SIDE OF THE DOOR.
2.
3.
4.
KEYED NOTES:
TYPICAL WIRING SHALL BE 4#22 AWG.
PROVIDE 2#12 AWG FOR CONTROL WIRING BETWEEN
ALL ECO SYSTEM LIGHT FIXTURES AND BUS SUPPLY.
LUTRON ECO SYSTEM BUS SUPPLY. COORDINATE
MOUNTING WITH CONTRACTING OFFICER.
JUNCTION BOX FOR LUTRON SHADE SYSTEM CONTROL.
1 1 1
2 TYP
D
D
D
D
D D
7 7
2 2
4 2
2 4 4
5 5
5 5
2 4
S3
E
E
X1
X1
X1
3D
3 3
6 6
S3S3
S D
S
S
S bS c
X1
FWJH059032FWJH059032
CONF.
DEPT.
WORK
CERT.
CHIEF
ALARM
AGENT
MEN’S
ROOM
CHIEF
CHIEF
ROOM
VEST
LOBBY
OFF.
TECH SERV
CORR
DINING
PROTECTIVE
CLOTHING
PHYSICAL
FITNESS
FIRE EXT
ROOM
CNTL. RM
TOILET
COMM
COMP
CORR
MECH
ELECT
SCBA
BUNK RM BUNK RM
122 123
BUNK RM BUNK RM
146 147
BUNK RM BUNK RM
BUNK RM
125 126
BUNK RM BUNK RM
127 143
BUNK RM BUNK RM
144 145
BUNK RM
LAUNDRY
INFECTIOUS
CONTROL
118114
CORR
TLT
JAN
CORR
CORR
BAYS
CORR
COVERED ENTRY
OUTDOOR EATING AREA
ROOM
VEST
114A
BATHROOM
BATHROOM
KITCHEN
ASSIST.
OFFICE
OFFICE
TRAINING
TRAINING
AUDIO VISUAL
STORAGE
COMPUTER
SIMULATION
LOCKER
ROOM
(AFFF)
STORAGE
HOSE
STORAGE
APPARATUS
136A
WOMEN’S
BREAK ROOM
S c a l e
F o r
M i c r o f i l m i n g
I n c h e s
M i l l i m e t e r s
no. date revisionby
191 1615141312111098765432 17 18
N
M
L
K
J
I
H
G
F
E
D
C
B
A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
FILENAME: PLOT DATE: PLOT TIME:dn10e120_339673.dgn 6/30/2008 6:53:39 PM
3001 PGA BOULEVARD - SUITE 300
PALM BEACH GARDENS, FLORIDA
(561) 904-7400 (561) 904-7401 (FAX)
EB0000072 AAC001992 LC26000188
FINAL SUBMITTAL
JUNE 27, 2008
TEXAS AIR NATIONAL GUARD
REPLACE FIRE STATION
ELLINGTON FIELD - HOUSTON, TEXAS
ELECTRICAL FLOOR PLAN - POWER
1/8"=1’-0"
N
ELLINGTON FIELD - HOUSTON, TEXAS
REPLACE FIRE STATION
TEXAS AIR NATIONAL GUARD
J SEIBERT
ELECTRICAL
POWER PLAN
E-120
GFI
GFI
GFI
WP/GFI
WP/GFI
WP/GFI WP/GFI
E-401
E-401
GFI
GFI
GFIGFI
GFI
ACT
GFI
GFI
ACT
GFI
ACT
GFI
AFI
AFI
AFI
AFI
AFI
AFI
AFI
AFI
AFI
AFI
AFI
AFI
AFI AFI
AFI AFI
AFI AFI AFI AFI
AFI
WP/GFI
WP/GFI
WP/GFI
WP/GFI
WP/GFI
CL
CL
E-503
+24"
+24"
+24"
+24"+24"
+24"
GFI
+24"
GFI
+24"
GFI
ACT
GFI
GFI
+42
+24"
GFI
GFI
WP/GFI
WP/GFI
WP/GFI
AFI AFI AFI AFI AFI AFI
AFIAFIAFIAFIAFI
E-503
E-401
GFI
GFI
ACT
GFI
ACT
GFI
GFI
GFI
GFI
GFI
GFI
GFI
E-401
L2-30
L2-5
L2-30
L2-5
L1A-5
L1A-23 L2-3
L1A-5
L1A-7 L1A-7
L2-7
L1A-9
L1A-9 L2-5
L2-5
L1A-13
L1A-13
L1A-15
L1A-15
L2-7
L2-7
L1A-11
L1A-11
L2-9
L2-9
L2-9
L2-11L2-11L2-11
L2-11
L2-13
L2-13
L2-13
L2-13 L2-15 L2-15
L2-15
L2-15
L2-21
L2-30
L3-21
L2-31
L3-21
L3-17
L3-17
L2-21
WP/GFI
L2-29
L3-21
L3-21
L3-19
L3-19
L3-19
L3-19
L2-18 L2-18 L2-18
L2-20
L2-20 L2-20
L2-20
L2-18
+48"
L3-15
L3-15
L2-29
L3-1
+48" +48" +48" +48"
+48" +48"+48"+48"
L3-11
L3-11
L3-13
L3-9
L3-13 L3-13 L3-13
L3-9 L3-9
L3-14 L3-12
GFI
+24"
L3-14
L3-1
L3-1
L3-1
L3-12
GFI
+24"
L3-12
GFI
+24"
L3-12
GFI
+24"
L3-10
GFI
+24"
L3-10
L2-29
L3-10
L3-10
L2-29 L3-8
L3-8
L2-32
GFI
+24"
L3-8
GFI
+24"
L3-8
GFI
+24"
L3-6
GFI
+24"
L3-6
GFI
+24"
L3-6
GFI
+24"
L3-6
L2-32
L3-14
L2-26
L2-26
L2-26L2-24
L2-24
L1B-30
L2-26
L1B-32
L2-28
L1B-32
L1B-30
L2-28
L2-22
L2-22
L2-21
AFI
L2-24 L2-22
L2-24 L2-22
L1B-28
AFI
L2-27
L2-27L2-27L2-25
L1A-29
AFI
L2-25
AFI
L2-27
L2-21
L1B-31
L2-21
L2-25L2-23L2-23
L1A-29
L2-25L2-23L2-23
L1A-27
L2-16
L2-16
L3-14
L2-14
L2-10
L2-10
L2-10
L2-10
L2-10
L2-12
L2-8
L2-12
L2-12
L2-8
L2-8
L2-6
L1A-17
L2-6 L2-6
L2-6
L2-6
L1A-19 L1A-19
L1A-21L1A-21
L1A-17
L2-4
L2-2 L2-2
L2-4
L2-2 L2-2
L2-3
L2-1
L2-3
L2-3
L2-1
L1A-3
L1A-3
L2-1
L2-1
L1A-1
L1A-1
L2-7
L2-30
L2-32
L2-32
L2-14
L2-14
L1A-20
L1A-22
L1A-24
L1A-26
L1A-25
TYP
TYP
WP/GFI
L2-30
FWJH059032FWJH059032
E-402
CONF.
DEPT.
WORK
CERT.
CHIEF
ALARM
AGENT
MEN’S
ROOM
CHIEF
CHIEF
ROOM
VEST
LOBBY
OFF.
TECH SERV
CORR
DINING
PROTECTIVE
CLOTHING
PHYSICAL
FITNESS
FIRE EXT
ROOM
CNTL. RM
TOILET
COMM
COMP
CORR
MECH
ELECT
SCBA
BUNK RM BUNK RM
122 123
BUNK RM BUNK RM
146 147
BUNK RM BUNK RM
BUNK RM
125 126
BUNK RM BUNK RM
127 143
BUNK RM BUNK RM
144 145
BUNK RM
LAUNDRY
INFECTIOUS
CONTROL
118114
CORR
TLT
JAN
CORR
CORR
BAYS
CORR
COVERED ENTRY
OUTDOOR EATING AREA
ROOM
VEST
114A
BATHROOM
BATHROOM
KITCHEN
ASSIST.
OFFICE
OFFICE
TRAINING
TRAINING
AUDIO VISUAL
STORAGE
COMPUTER
SIMULATION
LOCKER
ROOM
(AFFF)
STORAGE
HOSE
STORAGE
APPARATUS
136A
WOMEN’S
BREAK ROOM
S c a l e
F o r
M i c r o f i l m i n g
I n c h e s
M i l l i m e t e r s
no. date revisionby
191 1615141312111098765432 17 18
N
M
L
K
J
I
H
G
F
E
D
C
B
A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
FILENAME: PLOT DATE: PLOT TIME:dn10e130_339673.dgn 6/30/2008 6:53:51 PM
3001 PGA BOULEVARD - SUITE 300
PALM BEACH GARDENS, FLORIDA
(561) 904-7400 (561) 904-7401 (FAX)
EB0000072 AAC001992 LC26000188
FINAL SUBMITTAL
JUNE 27, 2008
J
J
J
J J J J
M
M
JJ
J
J J J J J J
J
J J J
J J J J J
J J J
J
J
M
M
M
J
J
J
J
J J
J
JJ
J
M
J
M
M
M
M
J
J
M
M
M
M M
M
M
M M
J
J
J
J
M
J J
M
M M M MM M
MMMMMM
M
M
M
J
J
SV
J
J
ELLINGTON FIELD - HOUSTON, TEXAS
REPLACE FIRE STATION
TEXAS AIR NATIONAL GUARD
J SEIBERT
ELECTRICAL
E-130
MECHANICAL & SPECIALTY SYSTEMS
ELECTRICAL FLOOR PLAN - MECHANICAL & SPECIALTY SYSTEMS
1/8"=1’-0"
N
J
E-504
E-502
E-502
WASHER
DRYER
J
E-401
OVERHEAD DOOR
TYP
KEYED NOTES:
GFI
CU-6
WATER COOLER
D
84"
E-401
HPS
BX-1
BX-2
BX-3
BX-4
BX-5
BX-6
EF-2
EF-3
HPS
EF-4
HPS
HPS
EF-7
EF-5
EF-9
AHU-2
G GOLDSMITH
HPS
EF-10
84"
84"
L4-12
L1B-1
L1B-11
LB1-13
L4-13
L4-2
L4-4 D
GFI
L4-6 D
GFI
L4-8 D
GFI
L4-20
L4-20
L4-20
L4-20
L4-18
EF-8
SHP
SHP
L4-18
L4-18
L4-18
L1B-17
L3-30
2 2 2 2 2
L3-32 L3-34 L3-36 L3-38 L3-40 L3-42
L1B-19
L1B-17
L3-5,7
L3-16
L3-3
L4-12 L4-12
L1B-11
L1B-8
L1B-10
L1B-10L1B-10 L1B-15
L1B-10
L4-10
L1B-15
L1B-8 L1B-8
L1B-8
3 4 3
SHP
SHP
L5-39,41
L5-39,41
L5-31,33
L5-35,37
L5-35,37
L5-31,33
L1B-7
L6-22
L5-9,11
L1B-5
ERV-1
L1B-3
L1B-9
L1B-9
KEF-1
KSF-1
L3-18 L3-20 L3-22 L3-24 L3-26 L3-28
L1B-19
2 2 2 2 2
EFU-10
2/1
2/1
EFU-3
2/1
EFU-5
2/1
EFU-2
3/1
2/1
L6-1,3
EFU-1
2/1
EFU-4
H1-12,14,16
EF-6
3/1
H1-12,14,16
L6-17,19
2/1 30
2/1
2/1
2/1
EFU-7 EFU-9
EFU-8EFU-6
L6-14,16
L6-10,12
H1-13,15,17 H1-13,15,17 H1-13,15,17 H1-13,15,17 H1-13,15,17
H1-19,21,23 H1-19,21,23 H1-19,21,23 H1-19,21,23 H1-19,21,23
H1-19,21,23
H1-13,15,17
7 SDP-25,27,29
L3-23,25,27
EXTRACTOR
3/1
SCBA
SDP-26,28,30
3/1
L6-21
AD-1
MB-8
AIR COMPRESSOR
SDP-31,33,35
SDP-25,27,29
S S
L2-36
L2-34
PROJECTION
SCREEN
PROJECTION
SCREEN
2/4X
L6-9,11 L6-6,8
EFU-1 EFU-2 EFU-4 EFU-6 EFU-8
EFU-1 EFU-3 EFU-5 EFU-7 EFU-9
EFU-10
EFU-10
L5-32,34
8 8 8 8 8 8
TV
TV
TV
TV 72"
L1B-27
TV
L1B-27
72" 72"
TV
L1B-27 L1B-29
72" 72"
TV TV
L1B-29
72"
TV
L1B-29
L1B-31
72"
TVTVTVTV
L1B-31L1B-31
72"72"72"
L1B-33L1B-33
TVTV
L1B-33
72"72"
VP-1
L3-29,31
L6-5,7 L6-13,15
L6-2,4 L6-18,20
TV
L3-2
L4-27
WP
E-504
TYP
FWJH059032
96"
+72"
TVL1B-3
13L3-4
L4-22
FIELD VERIFY EQUIPMENT EXACT LOCATION
AND COORDINATE ELECTRICAL REQUIREMENTS
WITH SUPPLIER AND ADJUST ACCORDINGLY.
JUNCTION BOX FOR OVERHEAD CORD REEL.
PROVIDE CORD REEL AND CONNECT IN
JUNCTION BOX
JUNCTION BOX FOR SINGLE STATION SMOKE
DETECTOR. TYP IN ALL BUNK ROOMS.
JUNCTION BOX FOR DOOR LOCK POWER SUPPLY.
JUNCTION BOX FOR SENSOR OPERATED
TRANSFORMER. MOUNT AT 44" AFF.
DEDICATED RECEPTACLE FOR VENDING MACHINE.
PORTABLE AIR COMPRESSOR. VERIFY RECEPTACLE
TYPE REQUIRED. PROVIDE RECEPTACLE AND
MATCHING PLUG.
PROVIDE INTERLOCK BETWEEN DOOR OPENING
CIRCUITS AND EXTRACTION FAN UNIT CONTROLS.
REFER TO DWG E-604.
PROVIDE INTERLOCK BETWEEN DOOR CIRCUITS
AND EXHAUST FANS. REFER TO DWG E-604.
EMERGENCY POWER OFF PUSHBUTTON STATION
FOR GAS GRILL.
JUNCTION BOX FOR RADIANT HEATER CONTROL POWER.
MASTER DOOR CONTROL MOUNT 42" ABOVE FINISHED
FLOOR TO BOTTOM OF ENCLOSURE.
EMERGENCY SHOWER ALARM.13
CONF.
DEPT.
WORK
CERT.
CHIEF
ALARM
AGENT
MEN’S
ROOM
CHIEF
CHIEF
ROOM
VEST
LOBBY
OFF.
TECH SERV
CORR
DINING
PROTECTIVE
CLOTHING
PHYSICAL
FITNESS
FIRE EXT
ROOM
CNTL. RM
TOILET
COMM
COMP
CORR
MECH
ELECT
SCBA
BUNK RM BUNK RM
122 123
BUNK RM BUNK RM
146 147
BUNK RM BUNK RM
BUNK RM
125 126
BUNK RM BUNK RM
127 143
BUNK RM BUNK RM
144 145
BUNK RM
LAUNDRY
INFECTIOUS
CONTROL
118114
CORR
TLT
JAN
CORR
CORR
BAYS
CORR
COVERED ENTRY
OUTDOOR EATING AREA
ROOM
VEST
114A
BATHROOM
BATHROOM
KITCHEN
ASSIST.
OFFICE
OFFICE
TRAINING
TRAINING
AUDIO VISUAL
STORAGE
COMPUTER
SIMULATION
LOCKER
ROOM
(AFFF)
STORAGE
HOSE
STORAGE
APPARATUS
136A
WOMEN’S
BREAK ROOM
S c a l e
F o r
M i c r o f i l m i n g
I n c h e s
M i l l i m e t e r s
no. date revisionby
191 1615141312111098765432 17 18
N
M
L
K
J
I
H
G
F
E
D
C
B
A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
FILENAME: PLOT DATE: PLOT TIME:dn10e140_339673.dgn 6/30/2008 6:54:05 PM
3001 PGA BOULEVARD - SUITE 300
PALM BEACH GARDENS, FLORIDA
(561) 904-7400 (561) 904-7401 (FAX)
EB0000072 AAC001992 LC26000188
FINAL SUBMITTAL
JUNE 27, 2008
MM
M
M
M
M M
M M
M
M
M
M
M
M
M
M
M
M
M
M
M
M M M M M M
MMMMMM
S M
S M
M
M
M
M
M
VVVV
V
84"
V
72"
54"
54"
M
S M
WP
M
M
M
M
M
V
V V
V
V V
V V
V
V
V V V V V V V
V
V V
V
S
S
M
M M
M
M
M
M
96"
M
M
M
M
M
M
S MS M
S SM
M
S
M
S
M
S
M
WP WP
WP
WP
WPWP
M
SM
WP
S
M
WP
M
S
+48"
84"
WP
WP WP
WPWP
WP
WP
WP
WP
WP
M
M
MM
M
M
M
M
M
M
M
M
M
M
M
M
M
MM
M
M
M
M
M
M
M
+72"
72"
MM
M
M
M M
M
M
M
M
M
M
M
M
M
S
S
S
S
S
S
SSS
S
S
S
S S
S
S
S
S
S S
S
S
S
S S
S
S S S S S S S
SSSSSS
S
SS
S
S S
S
S
S
S
SS
S
S
S
S
S
S
S
ELECTRICAL FLOOR PLAN - COMMUNICATIONS
1/8"=1’-0"
N
ELLINGTON FIELD - HOUSTON, TEXAS
TEXAS AIR NATIONAL GUARD
REPLACE FIRE STATION
ELLINGTON FIELD - HOUSTON, TEXAS
REPLACE FIRE STATION
TEXAS AIR NATIONAL GUARD
J SEIBERTJ SEIBERT
TEXAS AIR NATIONAL GUARD
REPLACE FIRE STATION
ELLINGTON FIELD - HOUSTON, TEXASELLINGTON FIELD - HOUSTON, TEXAS
REPLACE FIRE STATION
TEXAS AIR NATIONAL GUARD
J SEIBERT
E-140
ELECTRICAL
COMMUNICATIONS PLANCOMMUNICATIONS PLANCOMMUNICATIONS PLAN
E-401
G GOLDSMITH
G GOLDSMITHG GOLDSMITH
J
CLG MT
WALL MOUNT
24" AFF
J
J
J
CLG MT
WALL MOUNT
24" AFF
72"
72"72"72"72"72"72"
72" 72" 72" 72" 72"
E-503
TYP
FWJH059032FWJH059032FWJH059032FWJH059032
82828282
J
J
J
J
J
84"
84"
84"
84"84"
JUNCTION BOX WITH 1" CONDUIT
STUBBED TO ABOVE CEILING
FOR FUTURE SOUND SYSTEM
FURNISHED BY OTHERS
(TYPICAL OF 5 THIS ROOM)
AH PHILLIPSAH PHILLIPSAH PHILLIPS
E-503
E-402
JUNE 2008 JUNE 2008 JUNE 2008
CONF.
DEPT.
WORK
CERT.
CHIEF
ALARM
AGENT
MEN’S
ROOM
CHIEF
CHIEF
ROOM
VEST
LOBBY
OFF.
TECH SERV
CORR
DINING
PROTECTIVE
CLOTHING
PHYSICAL
FITNESS
FIRE EXT
ROOM
CNTL. RM
TOILET
COMM
COMP
CORR
MECH
ELECT
SCBA
BUNK RM BUNK RM
122 123
BUNK RM BUNK RM
146 147
BUNK RM BUNK RM
BUNK RM
125 126
BUNK RM BUNK RM
127 143
BUNK RM BUNK RM
144 145
BUNK RM
LAUNDRY
INFECTIOUS
CONTROL
118114
CORR
TLT
JAN
CORR
CORR
BAYS
CORR
COVERED ENTRY
OUTDOOR EATING AREA
ROOM
VEST
114A
BATHROOM
BATHROOM
KITCHEN
ASSIST.
OFFICE
OFFICE
TRAINING
TRAINING
AUDIO VISUAL
STORAGE
COMPUTER
SIMULATION
LOCKER
ROOM
(AFFF)
STORAGE
HOSE
STORAGE
APPARATUS
136A
WOMEN’S
BREAK ROOM
ELECTRICAL FLOOR PLAN - FIRE ALARM AND SECURITY
1/8"=1’-0"
N
TEXAS AIR NATIONAL GUARD
REPLACE FIRE STATION
ELLINGTON FIELD - HOUSTON, TEXASELLINGTON FIELD - HOUSTON, TEXAS
REPLACE FIRE STATION
TEXAS AIR NATIONAL GUARD
J SEIBERTJ SEIBERT
TEXAS AIR NATIONAL GUARD
REPLACE FIRE STATION
ELLINGTON FIELD - HOUSTON, TEXASELLINGTON FIELD - HOUSTON, TEXAS
REPLACE FIRE STATION
TEXAS AIR NATIONAL GUARD
J SEIBERT
ELECTRICAL
FIRE ALARM AND SECURITY PLAN
E-150
G GOLDSMITH
G GOLDSMITHG GOLDSMITH
E-502
TYP
FR
CCTV
WP
WP
WP
WP
WP
WP
WPWP
WPWP
E-503
E-503
FWJH059032FWJH059032FWJH059032FWJH059032
NOTES:
1.
AH PHILLIPSAH PHILLIPSAH PHILLIPS
J J
CCTV
J
CCTV
J
CCTV
REFER TO DETAIL 4 DRAWING E602 FOR CCTV
CAMERA RISER DIAGRAM.
J
CCTV
J
CCTV
J
CCTV
JUNE 2008 JUNE 2008 JUNE 2008
S c a l e
F o r
M i c r o f i l m i n g
I n c h e s
M i l l i m e t e r s
no. date revisionby
191 1615141312111098765432 17 18
N
M
L
K
J
I
H
G
F
E
D
C
B
A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
FILENAME: PLOT DATE: PLOT TIME:dn10e150_339673.dgn 6/30/2008 6:54:16 PM
3001 PGA BOULEVARD - SUITE 300
PALM BEACH GARDENS, FLORIDA
(561) 904-7400 (561) 904-7401 (FAX)
EB0000072 AAC001992 LC26000188
FINAL SUBMITTAL
JUNE 27, 2008
CR
DC
DC DC
CR
DC
DC
DC DC
DC DC
DC DC
DC
DC
DC
DC
CR
CR
CR
DC
DC
F
F
DC
DC
F
F
F
F
CR
CR
CR
CR
F
CR
CR
F
F
F
F
DC
DC
COCOCO
CO CO CO
CO
COCOCO
CO CO CO
DC
CR
F F
F
DCCR
w w w w w w w w w w w w w ww w w ww www w w
F
F
F A
A
F
F
F
F
F
F
F
F
F
F
F
F
F
F F
F F
FSTS
FF
F
F
F
F F
F
F F
F
F
F F
F F
F
F F
FF
F
TS TS
FA
S
S
S
S S
S
S
S
S
SS SS SS SS SS SS
SSSSSSSSSSSS
S c a l e
F o r
M i c r o f i l m i n g
I n c h e s
M i l l i m e t e r s
no. date revisionby
191 1615141312111098765432 17 18
N
M
L
K
J
I
H
G
F
E
D
C
B
A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
FILENAME: PLOT DATE: PLOT TIME:dn10e160_339673.dgn 6/30/2008 6:54:24 PM
3001 PGA BOULEVARD - SUITE 300
PALM BEACH GARDENS, FLORIDA
(561) 904-7400 (561) 904-7401 (FAX)
EB0000072 AAC001992 LC26000188
FINAL SUBMITTAL
JUNE 27, 2008
24 24
24 24
24 24 24 24 24
24 24
G
GG
G G
GGGG
G
G
G
G
G
G G
G G
G
G
G
G
G
BG
BG
BG
W
W
W
W
BG
24 24 G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
242424
24 24
G
G
G
G
G
WW
24 24 G
G G
G G
24 24
G
GGG
G
G
G
G
BG
BG
W
W
W W
BG BG
W
BG
BG
BG
BG
BG
W
BGBG
BG
BG
BG
BG
BG
BG BG
BG
ELLINGTON FIELD - HOUSTON, TEXAS
REPLACE FIRE STATION
TEXAS AIR NATIONAL GUARD
J SEIBERT
ELECTRICAL
ROOF PLAN
E-160
N
1/8"=1’-0"
E-505
E-505
E-505
E-505
#1/0 BARE COPPER (TYP)
NOTES:
1.
LIGHTNING PROTECTION PLAN
2.
3’-8"
3’-8"
ALTERNATE BID OPTION #4
PROVIDE DOWN CONDUCTOR IN COPPER.
PROVIDE STAINLESS STEEL COPPER TO
ALUMINUM SPLICER FOR CONDUCTORS.
CHANGE FROM ALUMINUM TO COPPER
BELOW ROOF LEVEL.
INSTALL GROUND LOOP 3’ TO 8’ FROM
STRUCTURE BURIED A MIN. OF 30".
E-505
E-505
FWJH059032
c a l e
F o r
M i c r o f i l m i n g
I n c h e s
M i l l i m e t e r s
no. date revisionby
191 1615141312111098765432 17 18
N
M
L
K
J
I
H
G
F
E
D
C
B
A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
FILENAME: PLOT DATE: PLOT TIME:dn10e401_339673.dgn 6/30/2008 6:54:43 PM
3001 PGA BOULEVARD - SUITE 300
PALM BEACH GARDENS, FLORIDA
(561) 904-7400 (561) 904-7401 (FAX)
EB0000072 AAC001992 LC26000188
FINAL SUBMITTAL
JUNE 27, 2008
M
M
M
M
M
M
M
M
M
M
M
M
M
M
1/4"=1’=-"
1/4"=1’-0"
1/4"=1’-0"
ELLINGTON FIELD - HOUSTON, TEXAS
REPLACE FIRE STATION
TEXAS AIR NATIONAL GUARD
J SEIBERT
ELECTRICAL
ENLARGED PLANS
E-401
KITCHEN RM 152/DINING RM 153 ENLARGED PLAN
S
J
S
KEYED NOTES:
MAIN
SWITCH
ATS
H1
T1
SDP
L5 L4 L3 L2
AHU-1
HP-4
HP-5
HP-3
HP-2
J
GFI
GFI
GFI
GFI
ACT
GFI
ACT
GFI
ACT
GFI
ACT
GFI
ACT
GFI
ACT
GFI
ACT
GFI
ACT
CONTROL RM 133 & COMM RM 134 ENLARGED POWER PLANS
CONTROL RM 133 & COMM RM 134 ENLARGED COMM PLANS
1/4"=1’-0"
SHP
SF-2
SHP
SHP
KEF-1
KMAU-1
G GOLDSMITH
IDS ALARM
CONTROL PANEL
DIVIDED PLUGMOLD
DATA OUTLETS SPACED
AT 12" OC
KEYED NOTES:
GROUND
BUS E-504
L4-7
L4-5
L4-3
L4-7
L4-7
L4-7
L4-25L4-23 L4-17
L4-21
L4-21 L4-19
L4-21
L4-11 L4-13L4-9 L4-23
L4-25
L4-27
L4-27
L4-23
L4-15
DIVIDED PLUGMOLD
RECEPTACLES SPACED
AT 12’ OC ALTERNATE
CIRCUITS
L1B-22
L1B-20
L1B-18
L1B-16
L1B-14
L1B-21,23,25
1LB-24
L2-19
L2-19
L2-19
GENERATOR
ANNUNCIATOR
PANEL
FUEL MONITOR
PANEL
L5-29
L6
GFI
+42"
L1B-26
CERTIFICATION RM 108 PLAN
1/4"=1’-0"
L2-33
L2-33
L2-9
L
A -8
L
A -8
L
A -1
L
A -1
L
A -1
L
A -1
L
A -1
L
A -1
L
A -1
L
A -1
L
A -1
L
A -1
CU-4
WP/GFI
L2-31
WP/GFI
L2-31
CU-5
CU-1
CU-3
L2-33
L5-28,30
L5-20,22
L5-2,4,6
L5-1,3,5
L5-36
L5-13,15
L5-25,27
L5-17,19
L5-21,23
ELECTRICAL RM 130/MECH RM 129/GENERATOR YARD ENLARGED PLANS
L4-1
L4-16
L4-14
2/4X
2/4X
3/4X
3/4X
3/4X
2/4X
SV
L4-27
DEDICATED CIRCIUT FOR FREEZER.
DEDICATED CIRCUIT FOR REFRIGERATOR.
DEDICATED CIRCUIT FOR MICROWAVE
DEDICATED CIRCUIT FOR GARBAGE DISPOSAL.
DEDICATED CIRCUIT FOR COFFEEMAKER.
JUNCTION BOX FOR HOOD POWER.
JUNCTION BOX FOR RANGE POWER.
REFER TO ARCHITECTURAL DWGS FOR
LOCATION AND MOUNTING HEIGHTS.
EMERGENCY POWER OFF PUSHBUTTON
STATION FOR RANGE.
L5-24,26
WH-2
WH-1
RCP-1
CU-2
CU-1A
L5-8,10,12
L5-16,18
L1AL1B
GFI
ACT
E-506
E-506
+84"
L1B-35
L1B-30
FA
STRION AIR
CONTROL PANEL
S
L2-35
FWJH059032
MONACO SYSTEM TRANSCEIVER
AH PHILLIPS
WP
PANEL ’GEN’
NEMA 4XSS
CT CABINET
UTILITY
METER
DEDICATED RECEPTACLE FOR SOUND SYSTEM RACK.
DEDICATED RECEPTACLE FOR DIGITAL RECORDER.
DEDICATED RECEPTACLE FOR IDS ALARM CONTROL PANEL.
NOT USED.
FIRE RATED PLYWOOD COMMUNICATIONS BACKBOARD.
NOT USED.
METER CONNECTION
TO DDC
POWER FOR DDC.
COORDINATE LOCATION
WITH EQUIPMENT
E-402
| 075-dn10e001_339673-001 |
| 076-dn10e100_339673-001 |
| 077-dn10e101_339673-001 |
| 078-dn10e102_339673-001 |
| 079-dn10e110_339673-001 |
| 080-dn10e120_339673-001 |
| 081-dn10e130_339673-001 |
| 082-dn10e140_339673-001 |
| 083-dn10e150_339673-001 |
| 084-dn10e160_339673-001 |
| 085-dn10e401_339673-001 |
File details come from the government source that posted it. Updated .