ELLINGTON FIELD - HOUSTON, TEXAS
REPLACE FIRE STATION
TEXAS AIR NATIONAL GUARD
N CAMARGO
M KUSSLER
A-602
TC ORLOWSKI
ROOM FINISH SCHEDULE
FWJH059032
JUNE 2008
S c a l e
F o r
M i c r o f i l m i n g
I n c h e s
M i l l i m e t e r s
no. date revisionby
191 1615141312111098765432 17 18
N
M
L
K
J
I
H
G
F
E
D
C
B
A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
FILENAME: PLOT DATE: PLOT TIME:dn10a602_339673.dgn 6/30/2008 6:35:32 PM
3001 PGA BOULEVARD - SUITE 300
PALM BEACH GARDENS, FLORIDA
(561) 904-7400 (561) 904-7401 (FAX)
EB0000072 AAC001992 LC26000188
FINAL SUBMITTAL
JUNE 27, 2008
DESIGN LOAD SCHEDULE
STRUCTURAL DESIGN CRITERIA & CODES
TOTAL LIVE LOAD
TOTAL LOAD
TOTAL DEAD LOAD
INSULATION
MATERIALS
L O
C A
T
IO
N S
D-2
D-1
CEILING
M/E/P
NOTES
SOILS AND FOUNDATIONS
RC-7
RC-6
RC-5
RC-4
RC-3
CAST BEAMS, TIE BEAMS:
REINFORCED CONCRETE
RC-2
FOOTINGS:
COLUMNS:
RC-1
3,000 PSI
4,000 PSI
4,000 PSI
3,000 PSI
6,000 PSIPRECAST LINTELS 6,000 PSIPRECAST LINTELS
EXTERIOR WALLS:
INTERIOR WALLS:
BEAMS, COLUMNS (TIES):
SLABS ON GRADE, TOP:
RC-14
RC-13
RC-12
RC-11
1 1/2"
1 1/2"
1"
1"
SLABS ON GRADE, BOTTOM:
RC-9
RC-10
RC-8
3"
3"
2"
FOOTINGS, BOTTOM AND SIDES:
FOOTINGS, TOP:
STRUCTURAL CONCRETE SHALL CONFORM TO ACI 301 SPECIFICATIONS,
AND SHALL DEVELOP THE FOLLOWING MINIMUM COMPRESSIVE
STRENGTHS AT 28 DAYS, AS WELL AS OTHER PROPERTIES SPECIFIED IN
THESE DOCUMENTS. SEE SPECIFICATIONS FOR DESIGN MIX
REQUIREMENTS.
CONCRETE SHALL BE READY-MIX, REGULAR WEIGHT FOR ALL
STRUCTURAL USES, WITH MINIMUM DRY DENSITY OF 140 LBS. PER
CUBIC FOOT.
PROVIDE CONTINUOUS REINFORCEMENT WITH ACI CLASS "B" LAP
SPLICES, OR AS NOTED OTHERWISE. IN BEAMS, LAP CONTINUOUS
BOTTOM STEEL OVER SUPPORTS AND CONTINUOUS TOP STEEL AT
MIDSPAN, UNLESS NOTED OTHERWISE.
REINFORCING STEEL SHALL BE DETAILED, FABRICATED AND INSTALLED
IN ACCORDANCE WITH ACI 318-02 AND ACI DETAILING MANUAL, ACI 315.
REINFORCING STEEL SHALL BE NEW, DEFORMED BARS, FREE OF
RUST, SCALE AND OIL, CONFORMING TO ASTM A-615, GRADE 60
WITH A MINIMUM YIELD STRENGTH = 60,000 PSI.
PROVIDE THE FOLLOWING MINIMUM CONCRETE COVERAGE OVER
REINFORCING UNLESS NOTED OTHERWISE:
REINFORCED CONCRETE UNIT MASONRY
M-1
M-2
M-3
M-4
M-5 PROVIDE SOLID GROUTED VERTICAL REINFORCED CELLS IN UNIT MASONRY
AS SPECIFIED ON PLANS, IN ADDITION, PROVIDE SOLID GROUTED
REINFORCED VERTICAL CELLS AT ALL CORNERS, INTERSECTIONS, EACH
SIDE OF ALL OPENINGS GREATER THAN 16 INCHES, ENDS OF WALL,
AND EACH SIDE OF CONTROL JOINTS. THESE BARS SHALL BE THE SAME
SIZE AS THE SCHEDULED REINFORCING SPECIFIED FOR EACH WALL.
MASONRY UNITS SHALL CONFORM TO ASTM C-90 WITH A MINIMUM
COMPRESSIVE STRENGTH OF 1,800 PSI, TO PROVIDE NET AREA
COMPRESSIVE STRENGTH OF MASONRY f’m = 1,500 PSI, UNLESS
OTHERWISE NOTED.
USE TYPE "S" MORTAR WITH A MINIMUM DESIGN COMPRESSIVE STRENGTH
OF 1,800 PSI. MASONRY AND GROUT SHALL MEET ASTM C476
SPECIFICATIONS AND SHALL DEVELOP A MINIMUM COMPRESSIVE
STRENGTH AT 28 DAYS OF 2,000 PSI, UNLESS OTHERWISE NOTED.
MASONRY CONSTRUCTION SHALL CONFORM TO ACI "BUILDING CODE
REQUIREMENTS FOR MASONRY STRUCTURES" (ACI 530-02/ASCE 5-02/
TMS 402-02), SPECIFICATIONS FOR STRUCTURES (ACI 530.1-02/
ASCE 6-02/TMS 602-02), AND COMMENTARIES RESPECTIVELY,
UNLESS NOTED OTHERWISE HEREIN.
G-3
G-2
G-1
CONCRETE DESIGN AND PLACEMENT SHALL BE IN STRICT ACCORDANCE
WITH ACI 318-02, "BUILDING CODE REQUIREMENTS FOR REINFORCED
CONCRETE".
NO REINFORCING BARS SHALL BE CUT OR OTHERWISE MODIFIED IN THE
FIELD. REINFORCING BARS SHALL NOT BE DISPLACED PRIOR TO OR
DURING CASTING TO ACCOMMODATE ANCHORS, EMBEDS OR OTHER ITEMS.
EMBEDDED ITEMS SHALL BE SECURELY FIXED AND MAINTAINED IN
POSITION PRIOR TO AND DURING CONCRETE PLACEMENT.
F-1
F-2
F-4
WELDED WIRE FABRIC REINFORCING SHALL CONFORM TO ASTM A-185.
PROVIDE MINIMUM 6 INCH LAPS, TYPICAL. PROVIDE ADEQUATE SUPPORTS
AND BOLSTERING TO PRESERVE THE SPECIFIED POSITION OF THE
MESH DURING CONCRETE PLACEMENT AND FINISHING. FLAT SHEETS ONLY.
ROLLS WILL NOT BE PERMITTED.
TERMINATE ALL DISCONTINUOUS ENDS OF TOP BARS WITH STANDARD
ACI HOOKS. TURN HOOKS UP OR DOWN INTO SUPPORTING STRUCTURE.
CORNER BARS SHALL BE SUPPLIED AND PLACED IN ADDITION TO
HOOKED ENDS, PER THE DETAILS IN THESE DOCUMENTS.
STANDING SEAM
METAL ROOF
WHERE WALLS, BEAMS AND FOOTINGS CHANGE DIRECTION, PROVIDE
CORNER BARS OF SAME SIZE AND QUANTITY AS THE SPECIFIED
LONGITUDINAL STEEL.
D-3
F-3
3/4" CHAMFER ALL EXPOSED CONCRETE EDGES, INCLUDING THOSE TO
RECEIVE STUCCO FINISH -UNLESS NOTED OTHERWISE.
ARCHITECTURAL AND MECHANICAL DRAWINGS: THE STRUCTURAL
DRAWINGS ARE PART OF THE CONTRACT DOCUMENTS AND DO NOT BY
THEMSELVES PROVIDE ALL THE INFORMATION REQUIRED TO PROPERLY
COMPLETE THE PROJECT STRUCTURE. THE GENERAL CONTRACTOR SHALL
CONSULT THE ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS
AND COORDINATE THE INFORMATION CONTAINED IN THESE DRAWINGS
WITH THE STRUCTURAL DRAWINGS TO PROPERLY CONSTRUCT THE
PROJECT.
F-5
G-4
S-1
S-2
S-3
S-4
STRUCTURAL STEEL
A P
P A
R A
T U
S
R O
O F
METAL DECKING
A D
M
IN
R O
O F
TRUSS / JOIST
2 2
NEG.
MAXIMUM POSITIVE AND NEGATIVE (PSF.) - WALLS
AREA ft.
ZONES
POSPOS NEG. NEG.POS
102 20
NEG.NEG. POS POS NEG.
50 100 200
POS.
POS.
NEG.
NEG. POS. POS.NEG.
POSPOS NEG.
> 500500
GROSS PRESSURES (PSF) - ROOF
POS. NEG.
- 36.7
-66.4 -61.1
-55.8
3 - O/HANG - - -
NEG.
> 100
-54.0
2 - O/HANG - - - --
- 38.1 22.2 18.7 -35.7 -34.6 -34.6
-48.7 -48.7
-77.7 -77.7
-77.0 -77.0
-88.3 -88.3
AREA ft.
ZONE
-77.7
-98.2
22.2
22.2
-77.7
- 91.1
-118.3
18.7
18.7
-77.7
-84.0
-100.6
41.7 -45.2 39.9 -43.4
-52.3
37.3 -41.7 35.0 -39.9 33.7 -38.1 31.1 -34.6 31.1 -34.6
31.1 -34.6 31.1 -34.633.735.037.339.941.7 -47.9 -44.3 -39.9
17.0
17.0
17.0
17.0
17.0
17.0
+24.0
+24.0
+24.0
-130.7
COMPONENT AND CLADDING DIAGRAM
N
1.
2.
3.
4.
WELDS SHALL CONFORM TO AWS D1.1 LATEST EDITION AS SPECIFIED.
REPAIR WELDS FOUND DEFECTIVE IN ACCORDANCE WITH AWS D1.1, 5.26
USE INTERMITTENT WELDS AT FIELD WELDS OF EMBED PLATES AND ANGLES
TO AVOID SPALLING OR CRACKING OF THE EXISTING CONCRETE.
BUTT JOINT WELDS SHALL BE COMPLETE JOINT PENETRATION (CJP) UNLESS
INDICATED OTHERWISE.
WELDING
PREFABRICATED OPEN WEB METAL JOIST
JOISTS SHALL BE DESIGNED, FABRICATED AND ERECTED IN ACCORDANCE
WITH THE STANDARD SPECIFICATIONS OF THE AISC AND THE STEEL JOIST
INSTITUTE.
2.
1.
3.
4.
5.
6.
7.
8.
9.
#7 BARS 42"
#8 BARS 48"
#9 BARS 54"
#4 BARS 24"
#5 BARS 30"
#6 BARS 36"
M-6
M-7
M-8
M-9
M-10
GROUTED CELLS SHALL BE VIBRATED DURING PLACEMENT OF GROUT.
M-11
M-12
M-13
LINTELS SHALL HAVE 8" MINIMUM BEARING AT EACH END.
M-14
M-15
M-16
INSTALL MASONRY CONTROL JOINTS WHERE SHOWN ON PLANS, AND
AT CHANGES IN WALL HEIGHT OR THICKNESS.
PROVIDE SAWED BLOCK CLEANOUT HOLES AT THE BASE OF EACH
VERTICAL REINFORCED CELL. LOCATE CLEANOUTS BELOW FINISHED
GRADE WHERE POSSIBLE.
ALL GROUTED LIFTS SHALL BE LIMITED TO A VERTICAL HEIGHT OF FIVE
(5) FEET.
ALL GROUTED CELLS AND MASONRY COLUMNS SHALL BE POURED A
MINIMUM OF TWO (2) HOURS PRIOR TO POURING THE NEXT VERTICAL LIFT.
REINFORCING FOR MASONRY SHALL CONFORM TO ASTM A-615, GRADE
60. PROVIDE THE FOLLOWING MINIMUM LAP SPLICES, UNLESS NOTED
OTHERWISE ON PLANS.
PROVIDE FULL MORTAR BEDDING AROUND ALL REINFORCED MASONRY
CELLS TO BE GROUTED.
PROVIDE BENT CORNER BARS OF SAME TOTAL AREA AS HORIZONTAL
REINFORCEMENT, OR AS SPECIFIED IN BOND COURSES. ONE CORNER
BAR SHALL RUN OUTSIDE OF ANY VERTICAL STEEL PASSING
THROUGH THE CELL.
STEEL DECK
O/H
O/H
21 1 a a a
3 3
O/H
O/H a a 3
O/H a a
O/H a a
O/H
O/H
O/H a a
2 2
1 12
O/H a a a
O/H
O/H
O/H
O/H
O/H
O/H
DESIGN OPEN WEB STEEL JOISTS PER STRUCTURAL DESIGN CRITERIA
SEE D-1 TO D-6 / THIS SHEET
FOOTINGS HAVE BEEN DESIGNED AND PROPORTIONED FOR A MAXIMUM
ALLOWABLE SOIL BEARING PRESSURE OF 3,000 POUNDS PER SQUARE
FOOT IN ACCORDANCE WITH THE ABOVE GEOTECHNICAL REPORT.
SITE PREPARATION SHALL BE DONE IN ACCORDANCE WITH THE
RECOMMENDATIONS OF THE GEOTECHNICAL REPORT
SOILS SHALL BE PREPARED FOR FOUNDATIONS AND SLABS AS
DESCRIBED IN THE ABOVE GEOTECHNICAL REPORT.
ELLINGTON FIELD - HOUSTON, TEXAS
REPLACE FIRE STATION
TEXAS AIR NATIONAL GUARD
R SYBRON
P GIRAITIS
S HOUSE
STRUCTURAL
GENERAL NOTES
S-001
D-4 WIND DESIGN CRITERIA:
BASE DESIGN WIND SPEED: 120MPH (3 SEC GUST)
IMPORTANCE FACTOR: 1.15
EXPOSURE CATEGORY C
OCCUPANCY CATEGORY: IV
ENCLOSURE CLASSIFICATION: ENCLOSED
INTERNAL PRESSURE
COEFFICIENTS: GCPI = %%p 0.18
D-5 ALL ROOFING AND WALL COMPONENTS INCLUDING, BUT NOT LIMITED
TO ROOFING MATERIALS, TRUSSES, DOORS AND WINDOWS SHALL BE
DESIGNED TO WITHSTAND DESIGN WIND PRESSURES. EACH
COMPONENT SHALL BE TREATED AS BOTH A COMPONENT AND
CLADDING AND AS A MAIN WIND FORCE RESISTING SYSTEM (MWFRS)
IN ORDER TO DETERMINE THE CONTROLLING WIND PRESSURE.
D-6 SEE SHEET S001 FOR COMPONENTS & CLADDING WIND LOADING
DIAGRAM AND PRESSURES
UNLESS OTHERWISE NOTED, BOLTS SHALL BE 34" DIAMETER A-325-N
AND SHALL BE USED IN BEARING-TYPE CONNECTIONS. ALL HIGH
STRENGTH BOLTS SHALL MEET THE REQUIREMENTS OF THE
"SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM
A-325 OR A-490 BOLTS".
TUBE STEEL SHAPES SHALL CONFORM TO ASTM A-500, GRADE B
WITH A MINIMUM YIELD STRESS OF 46 KSI. PIPE COLUMNS SHALL
CONFORM TO ASTM A-53, TYPES E OR S GRADE B, WITH A
MINIMUM YIELD STRESS OF 35 KSI, OR A501 WITH A MINIMUM
YIELD STRENGTH OF 36 KSI.
REINFORCE HORIZONTAL JOINTS 16" OC WITH CONTINUOUS 1-#9 GAGE
GALVANIZED LADDER-TYPE REINFORCING. PROVIDE PREFABRICATED
"TEE" AND CORNER PIECES. SEE TYPICAL DETAILS IN DRAWINGS.
STRUCTURAL STEEL W-SHAPE SECTIONS SHALL CONFORM TO THE
REQUIREMENTS OF ASTM A-992, GRADE 50. CHANNELS, ANGLES, PLATES
AND BARS SHALL CONFORM TO THE REQUIREMENTS OF ASTM A-36, WITH A
MINIMUM YIELD STRESS OF 36 KSI.
REFER TO ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS
FOR ADDITIONAL OPENINGS, DEPRESSIONS, FINISHES, INSERTS, BOLTS
SETTINGS, DRAINS, REGLETS, ETC. DISCREPANCIES SHALL BE BROUGHT
TO THE ATTENTION OF THE CONTRACTING OFFICER BEFORE
PROCEEDING WITH THE WORK.
THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE
WITH THE 2003 INTERNATIONAL BUILDING CODE, AS
AMENDED BY UFC 1-200-01 GENERAL BUILDING
REQUIREMENTS, 20 JUNE AND ANGETL 01-1-1 AIR NATIONAL
GUARD DESIGN POLICY, REV MARCH 2004.
WELD DECK TO JOIST BRIDGING DECK CONNECTION ANGLES WITH 5/8" PUDDLE
WELDS AT 1’-0" ON CENTER. LOCATE ANGLE IN DECK VALLEY.
LOCATE OPENINGS FOR EQUIPMENT PER OTHER DISCIPLINE DRAWINGS.
REINFORCE AROUND OPENINGS AS SPECIFIED AND PER ROOF DECK
NOTES SHEET S-601.
SEE SHEET S-501 AND S-510 FOR STANDARD DETAILS
WIND LOADS ARE AND SHALL BE BASED ON ASCE 7-02, MINIMUM DESIGN LOADS
FOR BUILDING AND OTHER STRUCTURES.
PENETRATIONS THROUGH SLABS, BEAMS OR FOOTINGS SHALL BE
SLEEVED INDIVIDUALLY. CORE DRILLING OF EXISTING CONCRETE
MEMBERS WILL NOT BE PERMITTED, UNLESS NOTED ON PLANS. SUBMIT
LOCATIONS AND SIZES OF ALL SLEEVES FOR CONTRACTING OFFICERS
APPROVAL PRIOR TO CASTING.
FOUNDATIONS AND SLABS ON GRADE HAVE BEEN DESIGNED BASED
ON THE DATA AND RECOMMENDATIONS PRESENTED IN THE
GEOTECHNICAL ENGINEERING REPORT BY TERRACON CONSULTING
ENGINEERS AND SCIENTISTS, HOUSTON, TEXAS; PROJECT NO. 92075193,
TITLED "PROPOSED FIRE STATION AND PARKING ELLINGTON FIELD AIR
NATIONAL GUARD BASE, HOUSTON, TEXAS", DATED MAY 4, 2007 AND
MODIFIED MAY 11, 2007.
MASONRY CONSTRUCTION ON THIS PROJECT SHALL BE ACCOMPLISHED
UNDER A CONTINUAL LEVEL 3 QUALITY ASSURANCE FROM A TESTING AND
AN INSPECTION AGENCY IN ACCORDANCE WITH THE PROVISIONS OF
ACI 530/ASCE5/TMS402 CHAPTER 1, SECTION 1.14, PROVIDED BY THE
CONTRACTOR. REPORTS SHALL BE SUBMITTED TO THE CONTRACTING
OFFICER.
PROVIDE HORIZONTAL REINFORCEMENT CONTINUOUSLY AT FLOOR AND
ROOF LEVELS, AT TOP OF WALLS, AND ABOVE AND BELOW OPENINGS.
MINIMUM REINFORCEMENT SHALL BE 1-#7 PER BOND BEAM.
JOIST SIZES AND CHORD SIZES INDICATED ON THE PLANS ARE MINIMUM
ONLY. DESIGN BY THE JOIST MANUFACTURER MAY RESULT IN A LARGER
SIZE. JOISTS SHALL HAVE DOUBLE ANGLE CHORDS.
DESIGN JOIST TOP CHORD AT END OF ROOF SUB-DIAPHRAGMS AND JOISTS
DESIGNATED AS DRAG STRUTS FOR ADDITIONAL AXIAL LOAD (BOTH
TENSION AND COMPRESSION) AS INDICATED ON THE ROOF FRAMING
PLANS.
PROVIDE CALCULATIONS, PRODUCT DATA, MATERIAL PROPERTIES,
CONNECTION DETAILS, ETC FOR ALL TYPES OF JOISTS. CALCULATIONS
SHALL BE STAMPED AND SIGNED BY AN ENGINEER REGISTERED IN THE
STATE OF TEXAS.
JOIST BRIDGING, BOTTOM CHORD BRACING, AND OTHER ACCESSORIES
SHALL BE PER THE MANUFACTURER’S STANDARDS AND AS INDICATED ON
THE DRAWINGS. BRACING SHALL EXTEND TO WALLS, SEE DETAILS ON
SHEET S-510.
JOISTS SHALL BE CAMBERED FOR DEAD LOAD. PROVIDE STANDARD S.J.I.
CAMBER. JOIST CAMBER SHALL BE SHOWN ON SHOP DRAWINGS.
a = 10’-0"
COMPONENTS & CLADDING GROSS WIND PRESSURES
COMPONENTS & CLADDING GROSS WIND PRESSURES
1.
2.
3.
4.
5.
LINEAR INTERPOLATION BETWEEN AREAS VALUES IS ACCEPTABLE.
COMPONENT AND CLADDING SHALL BE L x W OR L x 1/3 L WHICHEVER IS
GREATER.
DEDUCT 60% OF THE DEAD LOADS FOR THE NET UPLIFT PRESSURES.
DESIGN ROOF LIVE LOAD = 20 PSF.
O/H DENOTES ROOF OVERHANG.
N.T.S.
LOAD BEARING METAL FRAMING SYSTEM
a a
5 5 4
5 4 5
5 54
5 4 5
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
DESIGN EXTERIOR STUD ASSEMBLIES, IN ACCORDANCE WITH
CRITERIA SET FORTH ON THE DRAWINGS, NOTES D-1 THROUGH D-6
THIS SHEET AND AS SPECIFIED. SUBMIT CALCULATIONS AND SHOP
DRAWINGS STAMPED BY PROFESSIONAL ENGINEER. SIZES
INDICATED ARE MINIMUM.
EXTERIOR STUD ASSEMBLIES SHALL BE ASTM A446 GALV SHEET
STEEL, G60. STUDS SHALL BE C SECTION WITH A MINIMUM YIELD
STRENGTH OF 33,000 PSI FOR LIGHTER THAN 18 GAGE STUDS AND
WITH A MINIMUM YIELD STRENGTH OF 50,000 PSI FOR 18 GAGE AND
HEAVIER STUD
EXTERIOR STUDS SUPPORTING BRICK VENEER SHALL BE 18 GAGE
MINIMUM. BRICK VENEERS MINIMUM DEAD LOAD = 37 PSF.
TRACKS SHALL BE DEEP LEG TYPE AND WIDTH SHALL ALLOW FOR
FULL STUD BEARING. FASTEN TO STUDS WITH MINIMUM ONE #8
SCREW EACH FLANGE OR ALTERNATELY AT 18 GAGE OR HEAVIER
STUDS EACH STUD FLANGE MAY BE SHOP WELDED TO TRACK.
FASTEN TOP AND BOTTOM TRACKS AT 4 INCH STUDS OR SMALLER
TO STRUCTURAL STEEL MEMBERS WITHIN ONE 1/8 INCH FROM ENDS
AND AT STUD SPACING ON CENTER. AT 6 INCH STUDS OR LARGER,
FASTEN WITH MINIMUM (PDF) 2 INCH FROM ENDS AND AT STUD
SPACING ON CENTER. FULLY PENETRATE STEEL MEMBERS.
PROVIDE ADDITIONAL FASTENERS AS REQUIRED BY
MANUFACTURER.
ALLOW FOR 5/8 INCH MINIMUM VERTICAL DEFLECTION OF
COMPLETED WALL AT TOP CONNECTION OF WINDOWS TO ABOVE
STUD WORK.
ALLOW FOR VERTICAL BEAM DEFLECTIONS AND THERMAL
MOVEMENT AT STUD WALL CONNECTIONS VIA SLOTTED
CONNECTIONS.
WELDING OF STUDS SHALL BE SHOP WELDS AND AS SPECIFIED IN
ACCORDANCE WITH AWS D1.3.
ATTACH GYPSUM SHEATHING WITH SCREWS TO EACH SIDE OF
STEEL STUDS OR TUBE STEEL PER IBC TABLE 47G FOR LATERAL
BRACING. SCREWS MUST PENETRATE BY 1/4 INCH MINIMUM.
NO FIELD WELDING OF COLD FORMED METAL WILL BE PERMITTED
U.N.O.
UNLESS NOTED OTHERWISE, PROVIDE MINIMUM DOUBLE STUDS AT
ALL JAMBS, CORNERS, AND INTERSECTION. BRIDGING SHALL BE PER
THE MANUFACTURER’S RECOMMENDATIONS.
ENGINEERED METAL TRUSSES
MT-2
MT-1
MT-3
MT-4 COORDINATE METAL BRACING WITH MECHANICAL DUCT WORK
TRUSS DESIGN LOADS SHALL BE AS PER INDICATED IN THE LOAD
SCHEDULE, AS WELL AS PROVIDE FOR ADDITIONAL LOADINGS,
CONCENTRATED OR UNIFORM, AS INDICATED ON PLANS. FURTHER,
DESIGN TRUSS BOTTOM CHORDS TO SUPPORT A MINIMUM BOTTOM
CHORD UNIFORM DEAD LOAD OF 10 PSF AND A 100# CONCENTRATED
LOAD AT ANY POINT ON THE BOTTOM CHORD.
MT-5 TRUSSES SHALL BE DESIGNED TO TRANSFER DIAPHRAGM FORCES
DOWN TO BRACING ELEVATIONS SEE SHEET S-201.
DESIGN TRUSSES TO RESIST NET WIND UPLIFT PRESSURES (SEE
SHEET S-001) INDICATE NET UPLIFT TRUSS REACTIONS ON
SUBMITTAL CALCULATIONS.
RC-15 PROVIDE REINFORCING SPLICES AS INDICATED BELOW IN
CONFORMANCE WITH AN ACI CLASS B TENSION SPLICE.
(2002 ACI 318 CODE). NO REDUCTION SHALL BE PERMITTED
DUE TO BAR SPACING
BAR SIZE 3,000 PSI 4,000 PSI 5,000 PSI
#3
#4
#5
#6
#7
#8
#9
#10
#11
16"
22"
27"
35"
48"
63"
80"
102"
125"
16"
19"
23"
31"
42"
55"
69"
88"
108"
16"
19"
23"
31"
42"
55"
69"
88"
108"
CLASS B SPLICES FOR REINFORCEMENT, OTHER THAN TOP BARS
BAR SIZE 3,000 PSI 4,000 PSI 5,000 PSI
#3
#4
#5
#6
#7
#8
#9
#10
#11
18"
24"
30"
40"
54"
71"
90"
114"
140"
CLASS B SPLICES FOR "PLAIN REINFORCEMENT AS TOP BARS
21"
28"
35"
46"
63"
82"
104"
132"
162"
18"
24"
30"
40"
54"
71"
90"
114"
140"
REINFORCED CONCRETE UNIT MASONRY (CONTINUE)
FOR DECK SIZE, GAGE, AND FASTENING REQUIREMENTS, SEE FRAMING PLANS.
WELDING SHALL BE IN ACCORDANCE WITH AWS D1.3 "STRUCTURAL WELDING
CODE - SHEET STEEL".
DECKING SHALL HAVE A MINIMUM 1 1/2 INCHES BEARING ON ALL SUPPORTS.
DECKING SHALL BE CONTINUOUS OVER THREE SPANS MINIMUM, EXCEPT
WHERE SHOWN OTHERWISE.
FASTEN DECK AS NOTED PER PLAN AND METAL DECK SCHEDULE SHEET S-601.
1.
2.
3.
4.
5.
6.
7.
TRUSSES SHALL BE DESIGNED TO SUPPORT ALL
SUPERIMPOSED DEAD AND LIVE LOADS INDICATED. SUBMIT
DESIGN CALCULATIONS AND ERECTION DRAWINGS COMPLETE
WITH MEMBER PLACEMENTS AND CONNECTORS FOR TRUSS
TO SUPPORTING STRUCTURE AND TRUSS TO TRUSS
CONNECTIONS. DESIGN CALCULATIONS AND ERECTION
DRAWINGS TO BEAR THE SEAL OF A PROFESSIONAL ENGINEER
REGISTERED IN THE STATE OF TEXAS.
LOADS INDICATED ABOVE ARE MINIMUM DESIGN LOADS AND SHALL NOT BE
CONSTRUED TO BE ALL LOADS APPLICABLE TO THE DESIGN OF THE
PREFABRICATED OPEN WEB METAL JOISTS. DEAD LOADS INFERRED BY THE
DRAWINGS WHICH WOULD BE INCLUDED IN COMMON PRACTICE, INCLUDING
EQUIPMENT LOADS AND CONSTRUCTION LOADS SHALL BE INCLUDED IN THE
DESIGN.
VERIFY AND COORDINATE EQUIPMENT WEIGHTS, LOCATIONS, AND
ATTACHMENT REQUIREMENTS PRIOR TO JOIST FABRICATION. EQUIPMENT
SUPPLIER SHALL BE RESPONSIBLE FOR THE DESIGN OF THE VERTICAL
AND LATERAL SUPPORT OF THEIR EQUIPMENT. JOIST MANUFACTURER SHALL
PROVIDE ADDITIONAL DIAGONAL WEB MEMBERS AT CONCENTRATED LOAD
LOCATIONS.
NET WIND UPLIFT LOADS ON THE PREFABRICATED METAL JOISTS:
SEE C & C DIAGRAM AND WIND PRESSURE SCHEDULE THIS SHEET.
4,000 PSI
SLABS ON GRADE/ADMIN. BLDG:
DIMENSIONS: ALL DIMENSIONS AND ELEVATIONS SHOWN ON THE
STRUCTURAL DRAWINGS MUST BE VERIFIED AND COORDINATED WITH THE
ARCHITECTURAL DRAWINGS BY THE CONTRACTOR BEFORE PROCEEDING
WITH THE CONSTRUCTION. DISCREPANCIES SHALL BE BROUGHT TO THE
ATTENTION OF THE CONTRACTING OFFICER BEFORE PROCEEDING WITH THE
WORK.
FOUNDATIONS AND FOOTINGS SHALL BE LOCATED AT THE CENTERLINE
OF THE WALL OR COLUMN ABOVE, UNLESS NOTED OTHERWISE.
SLABS ON GRADE / APPARATUS
FWJH059032
FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL CONFORM
TO THE A.I.S.C. "MANUAL OF STEEL CONSTRUCTION", NINTH EDITION
AND THE AISC "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS", 1989.
D-7 SEISMIC LOADS
The following seismic design criteria shall be followed:
Site Class = D
Mapped 5% damped spectral response acceleration at short periods (Ss) = 0.0873
Mapped 5% damped spectral response acceleration at 1 sec period (S1) = 0.036
Sds = 0.09
Sd1 = 0.06
Seismic Design Category = A
Occupancy Category = IV
Seismic use group = III
BUILDING FRAME SYSTEM:
Administration Building - ordinary steel concentrically braced frames
Apparatus Bay - ordinary reinforced concrete moment frames
JUNE 2008
S-5 SUBMIT STRUCTURAL STEEL AND MISC. FABRICATIONS SHOP AND ERECTION
DRAWINGS FOR REVIEW BY THE ENGINEER. ANY SPLICES OR CONNECTIONS
NOT FULLY PROVIDED IN THESE PLANS SHALL BE DESIGNED BY AN ENGINEER
WHO OVERSEES THE DETAILING OF THE STEEL SHOP AND ERECTION
DRAWINGS, AND BEAR THE SEAL OF THAT INDIVIDUAL, BEING A REGISTERED
PROFESSIONAL ENGINEER LICENSED IN THE STATE OF TEXAS. PROVIDE
SEIGNED AND SEALED ENGINEERING CALCULATIONS FOR ANY SPECIAL
MOMENT SPLICE DESIGNS.
S c a l e
F o r
M i c r o f i l m i n g
I n c h e s
M i l l i m e t e r s
no. date revisionby
191 1615141312111098765432 17 18
N
M
L
K
J
I
H
G
F
E
D
C
B
A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
FILENAME: PLOT DATE: PLOT TIME:dn10s001_339673.dgn 6/30/2008 6:57:40 PM
3001 PGA BOULEVARD - SUITE 300
PALM BEACH GARDENS, FLORIDA
(561) 904-7400 (561) 904-7401 (FAX)
EB0000072 AAC001992 LC26000188
FINAL SUBMITTAL
TEXAS AIR NATIONAL GUARD
STRUCTURAL
FOUNDATION PLAN
S-101
0 8 16 24
1/8"=1’-0"
DENOTES STRUCTURAL WALL MARK - SEE SCHEDULE
DENOTES REFERENCE ELEVATION
C.J.
100’-0"
CX
W-X
TE-X
DENOTES COLUMN MARK - SEE PLAN AND SCHEDULE
LEGEND
FX DENOTES FOUNDATION MARK - SEE SCHEDULE
DENOTES THICKENED EDGE SLAB MARK - SEE SCHEDULE
CONCRETE OR GROUTED MASONRY COLUMN MARK
DENOTES DETAIL NUMBER
DENOTES SHEET WHERE
SECTION IS SHOWN
PLAN NOTES
1.
2.
3.
4.
5.
FOUNDATION PLAN N
SCALE: 1/8"=1"
F16
F17
F13
F9 F5
F11
F3
F6
F3
F3 F9
F3
F6
F6
F16
F6
F6
F6
F5
F5 F14
F4 F5
F5
F6
F6
F6
F7 F7
F17
F8
F9
F3
RAMP
UP
F3
F12
TE-1
TE-2
W-3
C12
TE-2 TE-2 TE-2 TE-2 TE-2
TE-2
W-1C10
S501
S501
S501 C4 F2
F1W-2
C5
C5
C10
C9
C5
F3
F3
S501
S501
S501
S501
S501
S501
C14
W-1
W-2
W-2 C10C11
F15
X
SXXX
R SYBRON
P GIRAITIS
S HOUSE
DENOTES 2-#5 x 6’-0" SLAB BARS WHERE
INDICATED
4" - 3000 PSI CONCRETE SLAB
W/6"x6"-W2.1 x W2.1 WWF (PLACE
AT TOP 1/3 OF SLAB) ON 10 MIL
VAPOR BARRIER ON TREATED,
COMPACTED BASE.
F5
S HOUSE
P GIRAITIS
R SYBRON
S-101
FOUNDATION PLAN
STRUCTURAL
TEXAS AIR NATIONAL GUARD
REPLACE FIRE STATION
ELLINGTON FIELD - HOUSTON, TEXASELLINGTON FIELD - HOUSTON, TEXAS
REPLACE FIRE STATION
TEXAS AIR NATIONAL GUARD
R SYBRON
P GIRAITIS
S HOUSE
STRUCTURAL
FOUNDATION PLAN
S-101
F4
F3
F5
C4
TYPICAL STEEL COLUMN
UNLESS OTHERWISE NOTED
C5 C11 C5C11
C11
C11 C11
F5
F6
F6
F6
F4
C8
TE-2 TE-2 TE-2 TE-2TE-2
F4
F3
F14
C5
C1
C11
C12
W-1
F15
C18
C18
F3
F1 F1
C10
C6
C10
C5C5
C11
C17
C11
C17
7.
8.
9.
SEE ARCHITECTURAL DRAWINGS FOR MORE
DETAILED DIMENSIONS AND INTERIOR WALL
ELEVATIONS.
SEE ARCHICTECTURAL DRAWINGS FOR MASONRY
CONTROL JOINT LOCATIONS.
SEE SHEET S-501 FOR TYPICAL WALL, FOOTING
AND SLAB DETAILS
SEE PLUMBING PLANS FOR FLOOR PITCHES IN
ROOMS WITH FLOOR DRAINS
TE-1
T E
-3
HIGH POINT
EL 99’-6"
TOP TRENCH
EL 99’-4"
EL 99’-6"
FIN FL
HIGH POINT
EL 99’-6"
HIGH POINT
EL 99’-6"
TOP TRENCH
EL 99’-4"
TOP TRENCH
EL 99’-4"
TOP TRENCH
EL 99’-4"
TOP TRENCH
EL 99’-4"
TOP TRENCH
EL 99’-4"
HIGH POINT
EL 99’-6"
HIGH POINT
EL 99’-6"
HIGH POINT
EL 99’-6"
HIGH POINT
EL 99’-6"
HIGH POINT
EL 99’-6"
T E
-1
T E
-1
C J
C J
C J
C J C J
C J
C J C J
C J
C J
C J
C J
C J
C JC J C J C J
C J
C J
C J C J
C J C J
C J
C J
C J C
J
C J
C
JC
J
C J
C J
C J
C J
C J
C J
C
JC
J C J
C J
C J
C J
C J
C J
C J C J
C J
C J
C J
C J
C J
C J
C J
C J
C J
11.
SEE PLAN
NOTE #10
C J
C J
10.
6.
S510
C J
C J
C J
TE-1
TYPICAL
R 9’-2"
R
S -5
C J
C J
C J
(97’10") F4
C8
(97’10") F4
C8
(97’10") F4
C8
(97’10") F4
C8
(97’10") F4 (97’10")
C15
C8
(97’10") F4
C8
(97’10") F4
C8
(97’10") F4
C8
(97’10") F4
C8
(97’10") F4 (97’10")
C15
(97’10")
FINISH FLOOR
EL (99’-6")
C J C J
F1
F1
F1
C J
F6
C J
W-2
C11C5
W-2
F1
W-2
C11C5
FINISH FLOOR
EL (99’-6")
4" - 3000 PSI CONCRETE SLAB
W/6"x6"-W2.1 x W2.1 WWF
(PLACE AT TOP 1/3 OF SLAB)
ON COMPACTED BASE.
F1
W-2
F1
W-2 F1
W-2
C5
C5
C5
10" - 4000 PSI CONCRETE SLAB REINF
W/ #7 @ 12" EACH WAY TOP & BOTTOM ON A
LAYER OF TRIMABLE, COMPACTABLE GRANULAR
FILL CONFORMING TO ASTM 448 NO. 10 WITH
ROCK FINES ON 10 MIL VAPOR BARRIER ON
TREATED, COMPACTED BASE.
PLACE REINF 1" FROM TOP , 3" FROM BOTTOM.
S-510
S-510
C5C5
C16
FLOOR MATT COORDINATE
RECESS WITH ARCH DWG
TYPICAL
T E
-1
EDGE OF
CONCRETE
SLAB TYPICAL
F3
F3
F2
F3
F12
C16
FOR LOCKERS PROVIDE ELEVATED CONCRETE PAD
SEE DETAIL 10 S-510; COORDINATE LOCATIONS AND
SIZE WITH ARCH DRAWINGS
S-601
S-601
T E
-5
S-501
SIMSIM
C5
C5
(97’10")
(97’10")
(97’10")
(97’10")
(97’10")
(97’10")
(97’10")
(97’10")
(97’10")
FINISH FLOOR ELEVATION 100’-0" REFERENCE TO
32.75 NGVD.
TOP OF ALL FOOTINGS SHALL BE AT ELEVATION
98’-8" UNLESS NOTED OTHERWISE
SEE ARCHITECTURAL DRAWINGS FOR LOCATION
OF ALL FLOOR DEPRESSIONS, SLOPES,
APPARATUS BAY DEPRESSIONS AS INDICATED.
TYPICAL AT ALL DOOR U.O.N.
ALL SHOWER RECESSED AREAS SHALL BE 2".
FOR DUMPSTER PLAN SEE DETAIL 8 SHEET S-510;
COORDINATE LOCATION WITH CIVIL DRAWINGS
43’-9"
13334
(98’-0")
TYPICAL THICKENED
EDGE UNLESS NOTED
OTHERWISE
(97’10")
S-501
F16
(97’10")
C11
/2
16’-0"
11’-10"
10’-2"
5’-0"
12’-0"
3’-9"
1’-3"
3’-8"
6’-6"
1’-1"
10’-9"
16’-6"
6’-9"
17’-8"
17’-0"
21’-0"
21’-0"
21’-0"
17’-8"
/2
/2
16’-0"
3"
8’-2 1/8 "
1’-2"
2"
24’-11 3/8 "
8"
/8
/8
/4
16’-0"
22’-1"
23’-3"
22’-1"
16’-7"
2’-6"
3"
11"
22’-8"
5’-9"
11"
/2
6 1/2 "
6 1/2 "
11"
11"
11"
11"
8"
8"
3’-0"
3’-0"
16’-0"
13’-4"
5’-11"
5’-8"
17’-8"
5’-8"
5’-11"
13’-4"
16’-6"
1’-8"
/2
/2
2’-9"
22’-2 3/8 "
8"
1’-6"
3’-4"
3’-4"
15’-0"
2’-0"
15’-0"
2’-0"
19’-0"
2’-0"
19’-0"
2’-0"
19’-0"
2’-0"
15’-0"
3’-4"
123’-6"
37643
F1
S-501
4" - 3000 PSI CONCRETE SLAB
W/6"x6"-W2.1 x W2.1 WWF
(PLACE AT TOP 1/3 OF SLAB)
ON COMPACTED BASE.
W-2
FACE OF VENEERFACE OF VENEER FACE OF VENEER
6"
S-501
6’-0"
6’-0"
44’-3"
13487
(98’-8")
(98’-8")
(98’-8")
C J
C J
C J
2#4 x 6’-0" LG
ADJACENT TO ALL
NON- CONTINUOUS
CONTOL JOINTS
(TYPICAL)
FINISH FLOOR
EL (100’-0")
2" RECESS AT
SHOWERS ONLY
COORDINATE
WITH ARCH DWG
TYP
RAMP
UP
RAMP
UP
LANDING
FF EL
(101’-0")
FF
EL +(101’-6")
TE-1
FWJH059032FWJH059032FWJH059032
434343
C11
C11
C J
C J
C J
C J
C J
DENOTES SLAB CONTROL
JOINT - SEE DETAILS
JUNE 2008
JUNE 2008
JUNE 2008
S c a l e
F o r
M i c r o f i l m i n g
I n c h e s
M i l l i m e t e r s
no. date revisionby
191 1615141312111098765432 17 18
N
M
L
K
J
I
H
G
F
E
D
C
B
A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
FILENAME: PLOT DATE: PLOT TIME:dn10s101_339673.dgn 6/30/2008 6:58:10 PM
3001 PGA BOULEVARD - SUITE 300
PALM BEACH GARDENS, FLORIDA
(561) 904-7400 (561) 904-7401 (FAX)
EB0000072 AAC001992 LC26000188
FINAL SUBMITTAL
JUNE 27, 2008
W
V
U
T
S
R
P
N
M
L
K
J
I
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
C1
S c a l e
F o r
M i c r o f i l m i n g
I n c h e s
M i l l i m e t e r s
no. date revisionby
191 1615141312111098765432 17 18
N
M
L
K
J
I
H
G
F
E
D
C
B
A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
FILENAME: PLOT DATE: PLOT TIME:dn10s102_339673.dgn 6/30/2008 6:58:30 PM
3001 PGA BOULEVARD - SUITE 300
PALM BEACH GARDENS, FLORIDA
(561) 904-7400 (561) 904-7401 (FAX)
EB0000072 AAC001992 LC26000188
FINAL SUBMITTAL
JUNE 27, 2008
W
V
U
T
S
R
P
N
M
L
K
J
I
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
C1
1/8"=1’-0"
0 8 16 24
H
IP
T R U
S S
G
IR
D E
R
T R
U S
S
G
IR
D E
R
T R
U S
S
ROOF FRAMING PLAN N
G
IR
D E
R T
R U
S S
G
IR
D E
R
T R
U S
S
S-520
S-521
S-520
S-520
B -3
L -1
L -1
L -1
L -1
S-102
ROOF FRAMING PLAN
STRUCTURAL
TEXAS AIR NATIONAL GUARD
REPLACE FIRE STATION
ELLINGTON FIELD - HOUSTON, TEXAS
S-520
S-520
S-520
T B
-1 L
-2
L-2
L-2
W x
H
IPT
R U
S S
H
IP
T R U
S S
S520
S-521
W x
W14x26 (111’-2")
W x
W x
W x
W x
W18x46 (111’-2")
W x
W x
S-520
S-520
GIRDER TRUSS
GIRDER TRUSS
GIRDER TRUSS
GIRDER TRUSS
T B
-1
C O
N T
B-2 (121’-2") B-2 (121’-2") B-2 (121’-2") B-2 (121’-2") B-2 (121’-2") B-2 (121’-2")
B-2 (121’-2") B-2 (121’-2") B-2 (121’-2") B-2 (121’-2") B-2 (121’-2")
B-2 (121’-2")
B-2 (121’-2") B-2 (121’-2") T
B -1
C O
N T
TB-1
TB-1
B-5
B -5
B -5
S-520
T B
-1
)TB-1 (111’-2")
TB-1 (111’-2")
S HOUSE
R PERE
R SYBRON
PLAN NOTES
W x
W14x26 (116’-6")
W14x26 (116’-6")
W x
/4
UPLIFT BRIDGING
UPLIFT BRIDGING
CROSS BRIDGING
12K5
K
K
K
B R
ID
G
IN
G
U P
L
IF
T B
R
ID
G
IN
G
U P
L
IF
T B
R
ID
G
IN
G
BROKEN BACK GABLE JOISTS BROKEN BACK GABLE JOISTS
S-522
S-522
S-522
LOW
ROOF
S-523
2 LOW
ROOF
S-523 ROOF
LOW
W x
/4
W x
/4
ROOF DECKING NOTES:
W x
(1
8K1
W x
(1
W x
W x
W x
) W14x26 (111’-1 1/2")
W14x26 (111’-1 1/2")
W x
W14x26 (116’-6")
W14x26 (116’-6")
W x
S-522
W x
W x
/4
W x
/4 x
/4
S-522
B B
-1
C O
N T
H S
S x x
/1
B -1
W x
H
IP
T R U
S S
S-522S-522
S-522S-522
S-522
ROOF
HIGH
S-522
S-522
D E
C K
DECK -1
D E
C K
D E
C K
D E
C K
D E
C K
DECK -2
DECK -2
S-522
S-522
OPP HAND
W x
(1
W x
/8
W x
/8
W x
/8
W x
(1
W x
/8
W x x
W x
GABLE JOISTS
B R
O K
E N
B A
C K
G A
B L
E G
IR
D
E R
J O
IS
T
S
B R
O K
E N
B A
C K
G A
B
E
G
IR
D E
R J
O
IS
T S
S-521
S-521
S-521
S-521
W16x36
(116’-6")
W x
W x
W x
W x
(1
W x
S-520
S-520
S-520
W16x36 (116’-6")
4’-0" O C
TB-1
(111’-2")
S-523
CROSS BRIDGING
CROSS BRIDGING
CROSS BRIDGING
CROSS BRIDGING
ALL STEEL BEAMS SHALL BE W16 x 36
UNLESS OTHERWISE NOTED ON PLAN
1.
ALL STEEL BEAMS SHALL BE AT ELEVATION 116’-6"
UNLESS OTHERWISE NOTED ON PLAN
4.
5.
2.
3.
p k p k p k p k p k p k p k p k p k p k p k p k p k p k p k p k
%%p 9kGIRDER TRUSS
%%p 9k
%%p 9k
%%p 9k
%%p 9k
52DLH1052DLH10 52DLH10
4 EQ SPAC
C8x11.5
RAFTERS
(VARIES) TYP
C8x11.5
RAFTERS
(VARIES) TYP
TOP OF WALL
W x
W x
(1
W x
S-523
S-523
S-523
S-523
S -5
S-520
S-520
S-520
S-521
S-521
S-521
S-521
6"
3’-4"
4’-0"
4’-0"
4’-2"
4’-3"
4’-3"
6’-0"
5’-0"
6’-0"
5’-6"
5’-0"
5’-0"
5’-6"
5’-6"
5’-0"
5’-0"
5’-6"
5’-6"
5’-0"
5’-0"
5’-6"
4 @ 4’-0" = 16’-0"
3’-4"
FOR GENERAL STRUCTURAL NOTES, SEE DRAWING S-001.
FOR DESIGN ROOF LOADS SEE GENERAL STRUCTURAL NOTES DWG S-001
A. ROOF DECK SHALL BE 1 1/2" x 22 GAGE TYPE B
GALVANIZED WITH THE FOLLOWING PROPERTIES:
I = .169 IN /FT
Sp = .186 IN /FT
Sn = .192 IN /FT
Fy = 33 KSI
THICKNESS = .0295
B. ROOF DECK SHALL BE ATTACHED PER METAL DECK
SCHEDULE SEE SHEET S-601:
SCREW ROOF DECK TO OPENING FRAMING WITH
#12 TEKS AT 6" O.C. BUT NOT LESS THAN 3 TEKS
PER MEMBER
A. ROOF DECK SHALL BE 1.5" x 20 GAGE TYPE C
GALVANIZED WITH THE FOLLOWING PROPERTIES:
Ip = .222 IN /FT
In = .201 IN /FT
Sp = .247 IN /FT
Sn = .234 IN /FT
Fy = 33 KSI
THICKNESS = .0358
B. ROOF DECK SHALL BE ATTACHED PER METAL DECK
SCHEDULE SEE SHEET S-601:
WELD ROOF DECK TO OPENING FRAMING WITH
5/8" PUDDLE WELDS AT 12" O.C. BUT NOT LESS
THAN 2 WELDS PER MEMBER
A. ROOF DECK SHALL BE 3" x 22 GAGE TYPE N
GALVANIZED WITH THE FOLLOWING PROPERTIES:
I = .772 IN /FT
Sp = .382 IN /FT
Sn = .433 IN /FT
Fy = 33 KSI
THICKNESS = .0295
B. ROOF DECK SHALL BE ATTACHED PER METAL DECK
SCHEDULE SEE SHEET S-601:
WELD ROOF DECK TO OPENING FRAMING WITH
5/8" PUDDLE WELDS AT 12" O.C. BUT NOT LESS
THAN 2 WELDS PER MEMBER
L -2
L -2
6.
W16x36 (111’-2")
W16x36 (116’-6")
W16x36 (111’-2")
21’-2"
14’-8"
S-521
W x
W x
W x
W x
W x
W x
W x
W x
W x
L -3
W x
L -1
TB-2
(111’-1 1/2")
TB-1
(116’-6")
(111’-1 1/2")
T B
-1 (1
T B
-1 (1
TB-1
(116’-6")
TB-2
T B
-2
S-522
LOW
ROOF
S-522
S-522
S-520 T
B
(110’-0")
8a
S-522
SIMILAR
TYPICAL ALL
ROOF CORERS
LIGHT WEIGHT CONCRETE
2" MIN AT DRAINS 6 1/2" AT EDGES
REINFORCED WITH
6"x 6" - W2.9 x W2.9 W W F
LIGHT WEIGHT CONCRETE
2" MIN AT DRAINS 5 1/2" AT EDGES
REINFORCED WITH
6"x 6" - W2.9 x W2.9 W W F
TOP OF WALL
(108’-0")
FWJH059032
S-523
(1
T B
-3 p k p k p k
JOIST/TRUSS MANUFACTURER TO DESIGN CHORDS FOR AXIAL
TENSION AND COMPRESSION FORCES INDICATED ON PLAN
METAL TRUSS SPACING 48" O C MAX.
S401
1 ENLARGE PLAN
H H
S x x
/4
W
IN
D O
W S
IL
H
S x x
/4
(W
IN
D O
W H
E A
D E
R
B E
T W
E E
N T
R U
S S
E
H
S x x
/4
(W
IN
D O
W H
E A
D E
R
B E
T W
E E
N T
R U
S S
E S
G
IR
D E
R T
R U
S S
H H
S x x
/4
W
IN
D O
W S
IL
L
/8
T Y
P A
R O
U N
D H
IG
H
1. ADMINISTRATION BUILDING ROOF: DECK-1 3. FLAT ROOF DECK: DECK-32. APPARATUS BUILDING ROOF DECK: DECK-2
S-521
S-521
R O
O F
P E
R
IM
E T
E R
TYPICAL AROUND LOW
ROOF PERIMETER
3’-6"
JUNE 2008
WT8x15.5 HORIZONTAL
BRACING (116’-6") TYP
DESIGN ALL HORIZONTAL
BRACING FOR 50K (SERVICE)
S-521
TYP 4 PLACESA
TEXAS AIR NATIONAL GUARD
R SYBRON
R PERE
S HOUSE
STRUCTURAL
FRAMING ELEVATIONS
S-201
3/16"=1’-0"
U S M K I H G F C B
U K I H E ABV R
V U P J H F C1 B A
TOP OF BEAM
EL 111’-2"
EL 100’-0"
FIN FLOOR
CONCRETE FOOTING
SEE PLAN & SCHEDULE
STEEL COLUMN
SEE PLAN AND
SCHEDULE
S E
E P
L A
N
BRACING ELEVATION ALONG GRID LINE 1
BRACING ELEVATION ALONG GRID LINE 3
BRACING ELEVATION ALONG GRID LINE A
11 12
2 3
TOP OF BEAM
EL 116’-6"
EL 100’-0"
FIN FLOOR
TOP OF BEAM
EL 100’-0"
FIN FLOOR
TOP OF BEAM
EL 116’-6"
EL 100’-0"
FIN FLOOR
TOP OF BEAM
TOP OF BEAM
EL 110’-0"
11’-10"
TOP OF BEAM
EL 116’-6"
TOP OF BEAM
EL 118’-6 3/8"
/8
9’-1"
13’-4 1/2 "
17’-8 1/2 "
21’-6"
18’-4"
21’-6"
19’-11"
9’-1"
/2
/2
9’-1"
5’-4 1/2 "
8"
11’-9"
14’-4"
8"
16’-2 1/2 "
21’-11"
20’-2"
12’-2"
9’-1"
9’-0"
/2
/2
/2
/2
10’-0"
8’-9"
12’-3 1/2 "
21’-6"
18’-4"
9’-4"
10’-10"
15’-8"
5’-6 3/4 "
16’-0"
8 12
22’-0"
EL 116’-6"
1 2 3
16’-0"
11’-10"
L 5" x 3" x 1/4" (LLV)
HSS 5x5x1/4
CROSS BRACING
1/2" PLATE TYP
L 5" x 3" x 1/4" (LLV)
1/2" PLATE TYP
/2
/2
10’-9"
EL 113’-8 3/4"
EL 110’-11"
TOP OF BEAM
EL 116’-6"
10 12 13
BRACING ELEVATION ALONG GRID LINE "B" (SHOWN)
BRACING ELEVATION ALONG GRID LINE "U" (SIMILAR)
GRID LINE "U"
GRID LINE "B"
16’-0"
BRACING ELEVATION ALONG GRID LINE "B" (SHOWN)
BRACING ELEVATION ALONG GRID LINE "U" (SIMILAR)
GRID LINE "U"
GRID LINE "B"
11’-10"
11’-10"
11’-10"
36O7
BRACING ELEVATION ALONG GRID LINE 12
TOP OF BEAM
EL 112’-2"
HSS 16x8x
4’-0"
6’-0"
6’-0"
GRID LINE "B" ONLY
FWJH059032
JUNE 2008
HSS 5x5x1/4
CROSS BRACING
DESIGN ALL HSS
BRACING WITH
%%p 50K (SERVICE)
TYP U.N.O.
TRUSS MANUFACTURER
TO PROVIDE BRACING TO
TRANSFER DIAPHRAGM
FORCES TO TOP OF BEAMS
%%p 20K IN TRUSS BRACING
HSS 5x5x1/4 BRACING
DESIGN BRACING WITH
%%p 60K (SERVICE)
HSS 5x5x1/4
BRACING AT
GRID LINE "B"
ONLY WITH
%%p 60K (SERVICE)
S c a l e
F o r
M i c r o f i l m i n g
I n c h e s
M i l l i m e t e r s
no. date revisionby
191 1615141312111098765432 17 18
N
M
L
K
J
I
H
G
F
E
D
C
B
A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
FILENAME: PLOT DATE: PLOT TIME:dn10s201_339673.dgn 6/30/2008 6:58:58 PM
3001 PGA BOULEVARD - SUITE 300
PALM BEACH GARDENS, FLORIDA
(561) 904-7400 (561) 904-7401 (FAX)
EB0000072 AAC001992 LC26000188
FINAL SUBMITTAL
| 041-dn10a602_339673-001 |
| 042-dn10s001_339673-001 |
| 043-dn10s101_339673-001 |
| 044-dn10s102_339673-001 |
| 045-dn10s201_339673-001 |