Pages 25-34.pdf
PDF 9 MB Posted
- Solicitation number
- W912L109R0027
About this file
DRAWINGS PAGES 25-34
View the file
Other files
Show all 48
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1/8"=1’-0"
ELLINGTON FIELD - HOUSTON, TEXAS
REPLACE FIRE STATION
TEXAS AIR NATIONAL GUARD
N CAMARGO
M KUSSLER
TC ORLOWSKI
EQUIPMENT PLAN
ARCHITECTURAL
A-160
1314 15
27 28 29
12 12
14 14
N
0 8 16 24
1/8"=1’-0"
EQUIPMENT PLAN AND SCHEDULE
8 8
16 8
A160
TYP BUNK ROOM EQUIP PLAN
NTS
NOTES:
1. REFER TO SHEET A-403 FOR BATHROOM DETAILS AND ACCESSORIES
2. REFER TO SHEET A-402 FOR KITCHEN DETAILS AND ACCESSORIES
3. PROVIDE SUPPORT BLOCKING AT EQUIPMENT/ACCESSORY MOUNTING LOCATIONS,
TYPICAL; SIZE PER EQUIPMENT/ACCESSORY MANUFACTURER’S RECOMMENDATIONS
EMERGENCY
GENERATOR CONDENSING
UNIT, TYP
63 64
11 11
NTS
TYP BUNK ROOM ELEVATION
1’-6"x 2’-0" BUILT-IN PLASTIC
LAMINATED LOCKER
PROVIDE CABINET
LOCKS (TYP)
BUILT-IN PLASTIC LAMINATED WITH
HARD WOOD EDGE DESK SURFACE
BASE
SUSPENDED CEILING
HANGING ROD
SINGLE DRAWER
FWJH059032
12 12
JUNE 2008
S c a l e
F o r
M i c r o f i l m i n g
I n c h e s
M i l l i m e t e r s
no. date revisionby
191 1615141312111098765432 17 18
N
M
L
K
J
I
H
G
F
E
D
C
B
A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
FILENAME: PLOT DATE: PLOT TIME:dn10a160_339673.dgn 6/30/2008 6:15:49 PM
3001 PGA BOULEVARD - SUITE 300
PALM BEACH GARDENS, FLORIDA
(561) 904-7400 (561) 904-7401 (FAX)
EB0000072 AAC001992 LC26000188
FINAL SUBMITTAL
JUNE 27, 2008
WD
CONF.
DEPT.
WORK
CERT.
CHIEF
ALARM
AGENT
MEN’S
ROOM
CHIEF
CHIEF
ROOM
VEST
LOBBY
OFF.
TECH SERV
CORR
DINING
PROTECTIVE
CLOTHING
PHYSICAL
FITNESS
FIRE EXT
ROOM
CNTL. RM
TOILET
COMM
COMP
CORR
MECH
ELECT
SCBA
BUNK RM BUNK RM
122 123
BUNK RM BUNK RM
146 147
BUNK RM BUNK RM
BUNK RM
125 126
BUNK RM BUNK RM
127 143
BUNK RM BUNK RM
144 145
BUNK RM
LAUNDRY
INFECTIOUS
CONTROL
118114
CORR
TLT
JAN
CORR
CORR
BAYS
CORR
COVERED ENTRY
OUTDOOR EATING AREA
ROOM
VEST
114A
BATHROOM
BATHROOM
KITCHEN
ASSIST.
OFFICE
OFFICE
TRAINING
TRAINING
AUDIO VISUAL
STORAGE
COMPUTER
SIMULATION
LOCKER
ROOM
(AFFF)
STORAGE
HOSE
STORAGE
APPARATUS
136A
WOMEN’S
BREAK ROOM
SOUTH ELEVATION
1/8"=1’-0"
NORTH ELEVATION
BLAST RESISTANT ALUMINUM /
GLASS CURTAIN WALL SYSTEM
DECORATIVE LIGHT
FIXTURE
BLAST RESISTANT ALUM /
GLASS WINDOW SYSTEM
MODULAR BRICK VENEER, TYP.
DECORATIVE LIGHT FIXTURE
ALUM GUTTER AND
DOWNSPOUT, TYP.
MODULAR BRICK VENEER, TYP
METAL DOWNSPOUT, TYP
A
A-301
A
A-301
ELLINGTON FIELD - HOUSTON, TEXAS
REPLACE FIRE STATION
TEXAS AIR NATIONAL GUARD
N CAMARGO
M KUSSLER
TC ORLOWSKI
EXTERIOR ELEVATIONS
A-201
NORTH AND SOUTH
ELEV + 116’-6"
TOB
ELEV + 121’-2"
TOB
BLAST RESISTANT ALUM/
GLASS CURTAIN WALL SYSTEM
RECESSED DORMER W/
CLERESTORY WINDOWS
RECESSED DORMER W/
CLERESTORY WINDOWS
ROOF
ZONE 1
+22.1 PSF
-35.0 PSF
ZONE 5
+37.2 PSF
-49.1 PSF
ZONE 4
+37.2 PSF
-40.4 PSF
ZONE 4
+37.2 PSF
-40.4 PSF
ZONE 5
+34.2 PSF
-43.9 PSF
ZONE 4
+34.2 PSF
-38.2 PSF
ZONE 4
+36.5 PSF
-39.8 PSF
ZONE 5
+36.3 PSF
-47.5 PSF
ZONE 5
+37.2 PSF
-49.1 PSF
ZONE 5
+36.3 PSF
-47.5 PSF
ELEV + 111’-2"
TOB
ELEV + 116’-6"
TOB
TOB
ELEV + 116’-6"
TOB
ZONE 5
+36.5 PSF
-47.8 PSF
ZONE 5
+36.5 PSF
-47.8 PSF
1 1 1
NOTES:
MIRROR PSF VALUES FOR LOUVERS
ON SOUTH WALL OF APPARATUS BAYS
STANDING SEAM METAL ROOF, TYP
10’H CMU/BRICK VENEER
SCREEN WALL
PRECAST CONC BASE
PRECAST CONC SILL, TYP.
DECORATIVE LIGHT FIXTURE, TYP
OUTDOOR AIR
INTAKE LOUVER
OVERFLOW
DRAIN, TYP
METAL LOUVER (L-7, SEE MECH)
CARD READER
24"H BRICK KNEE WALL
CARD READER
A B C D E F G H I J K L M
M L K J I H G F E D C B A
PRECAST CONC
PANELS, TYP.
PRECAST
CONC PANELS, TYP
OVERFLOW
DRAIN, TYP
METAL LOUVER
(L-6, SEE MECH)
OVERFLOW
DRAIN, TYP
METAL LOUVER
(L-9, SEE MECH)
STANDING SEAM METAL
ROOF, TYP
FWJH059032
BRICK SOLDIER
COURSE, TYP
BRICK SOLDIER COURSE, TYP
BRICK SOLDIER COURSE, TYP
CJ
LEGEND:
CJ
CJ
CJ
CJ
CJ CJCJ CJ
1’-6" x 1’-6" TEXAS STAR
PRECAST CONC LOGO,
REFER TO TYP DETAIL IN
DWG A202
CONTROL JOINT
METAL GUTTER SYSTEM
DOWNSPOUT, TYP.
ELEV + 111’-1 1/2"
BLAST RESISTANT ALUM / GLASS
STORE FRONT WINDOW SYSTEM
JUNE 2008
S c a l e
F o r
M i c r o f i l m i n g
I n c h e s
M i l l i m e t e r s
no. date revisionby
191 1615141312111098765432 17 18
N
M
L
K
J
I
H
G
F
E
D
C
B
A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
FILENAME: PLOT DATE: PLOT TIME:dn10a201_339673.dgn 6/30/2008 6:16:29 PM
3001 PGA BOULEVARD - SUITE 300
PALM BEACH GARDENS, FLORIDA
(561) 904-7400 (561) 904-7401 (FAX)
EB0000072 AAC001992 LC26000188
FINAL SUBMITTAL
JUNE 27, 2008
S c a l e
F o r
M i c r o f i l m i n g
I n c h e s
M i l l i m e t e r s
no. date revisionby
191 1615141312111098765432 17 18
N
M
L
K
J
I
H
G
F
E
D
C
B
A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
FILENAME: PLOT DATE: PLOT TIME:dn10a202_339673.dgn 6/30/2008 6:16:50 PM
3001 PGA BOULEVARD - SUITE 300
PALM BEACH GARDENS, FLORIDA
(561) 904-7400 (561) 904-7401 (FAX)
EB0000072 AAC001992 LC26000188
FINAL SUBMITTAL
JUNE 27, 2008
20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
2019181716151413121110987654321
1/8"=1’-0"
1/8"=1’-0"
EAST ELEVATION
WEST ELEVATION
E
A-302
MODULAR BRICK VENEER, TYP
BLAST RESISTANT ALUM /
GLASS STORE FRONT
WINDOW SYSTEM
ELLINGTON FIELD - HOUSTON, TEXAS
REPLACE FIRE STATION
TEXAS AIR NATIONAL GUARD
N CAMARGO
M KUSSLER
TC ORLOWSKI
EAST AND WEST
EXTERIOR ELEVATIONS
A-202
DECORATIVE ALUMINUM
LOUVER AT GABLE END
DECORATIVE ALUMINUM
LOUVER AT GABLE END
STEEL PIPE
BOLLARDS, TYP
STEEL PIPE
BOLLARDS, TYP
ELEV + 111’-2"
TOB
ELEV + 121’-2"
TOB
ELEV + 116’-6"
TOB
ELEV + 121’-2"
TOB
ELEV + 121’-2"
TOB
ELEV + 111’-2"
TOB
ELEV + 116’-6"
TOB
A-302
F
RECESSED DORMER, TYP.
F
A-302
A-302
E
ROOF
ZONE 1
+24.0 PSF
-38.1 PSF
ROOF
ZONE 1
+24.0 PSF
-38.1 PSF
ZONE 5
+33.3 PSF
-39.0 PSF
ZONE 5
+33.3 PSF
-39.0 PSF
ZONE 4
+33.3 PSF
-37.5 PSF
ZONE 4
+32.6 PSF
-36.7 PSF
ZONE 5
+39.6 PSF
-51.7 PSF
ZONE 5
+34.2 PSF
-43.9 PSF
ZONE 5
+34.2 PSF
-43.9 PSF
ZONE 4
+36.3 PSF
-39.7 PSF
ROOF
ZONE 1
+24.0 PSF
-38.1 PSF
ROOF
ZONE 1
+24.0 PSF
-38.1 PSF
ZONE 5
+33.3 PSF
-39.0 PSF
ZONE 4
+33.3 PSF
-37.5 PSF
ZONE 4
+33.3 PSF
-37.6 PSF
ZONE 5
+33.3 PSF
-39.0 PSF
ZONE 5
+39.6 PSF
-51.7 PSF
ZONE 5
+37.2 PSF
-49.1 PSF
ZONE 5
+37.2 PSF
-40.4 PSF
ZONE 4
+37.2 PSF
-40.4 PSF
ZONE 5
+36.1 PSF
-47.0 PSF
ZONE 4
+37.2 PSF
-40.4 PSF
CMU/BRICK VENEER
SCREEN WALL
SEE A-201 FOR PSF VALUES
AT CLERESTORY LOUVERS ON
SOUTH WALL OF APPARATUS BAYS
ZONE 4
+32.6 PSF
-36.7 PSF
ZONE 4
+33.3 PSF
-37.6 PSF
CLERESTORIES @ BREAK ROOM:
ZONE 4
+39.0 PSF
-42.3 PSF
STANDING SEAM METAL ROOF, TYP
STANDING SEAM
METAL ROOF, TYP
OVERHEAD SECTIONAL
DOOR, TYP
OVERHEAD SECTIONAL
DOOR, TYP
MODULAR BRICK
VENEER, TYP
MODULAR BRICK
VENEER, TYP
MODULAR BRICK
VENEER, TYP
MODULAR BRICK
VENEER, TYP
TOD
ELEV + 111’-1 1/2"
STANDING SEAM METAL ROOF, TYP
STANDING SEAM METAL ROOF, TYP
A-503
OUTDOOR AIR INTAKE LOUVER
RECESSED DORMER, TYP
METAL
LOUVER
(L-2, SEE
MECH)
DECORATIVE
LIGHT, TYP
SIGNAL LIGHT,
TYP
OUTDOOR AIR
INTAKE LOUVER,
BEYOND
BRICK SOLDIER COURSE, TYP
10’H CMU/BRICK VENEER
SCREEN WALL, BEYOND
DOWNSPOUT NOZZLE
24"H BRICK
KNEE WALL
ELEV + 111’-1 1/2"
TOD
A-503
A-503
12"x12" TEXAS STAR DECORATIVE
PRECAST CONC MEDALLION, TYP
STUCCO FINISH AT
RECESSED WALL
STUCCO FINISH AT
RECESSED WALL
12"x 12" TEXAS STAR DECORATIVE
PRECAST CONC MEDALLION
1’-6"x 1’-6" TEXAS STAR
DECORATIVE PRECAST
CONC MEDALLION
PRECAST CONC
PANELS, TYP
PRECAST
CONC PANELS
PRECAST
CONC PANELS
PRECAST CONC
PANELS
PRECAST
CONC PANELS, TYP
12"x 12" DECORATIVE
MEDALLION, TYP
12"x 12" TEXAS STAR
DECORATIVE PRECAST
CONC MEDALLION, TYP
ELEV + 110’-0"
TOB
ELEV + 108’-0"
TOB
FWJH059032
BRICK SOLDIER
COURSE, TYP
BRICK SOLDIER COURSE, TYP
BRICK SOLDIER
COURSE, TYP
NTS
/2
2" 2"
1’-0"
PRECAST CONC MEDALLION TYP DETAIL
3" 3"
1’-6"
LEGEND
CJ CONTROL JOINT
CJ CJ
METAL GUTTER SYSTEM
METAL GUTTER &
DOWNSPOUT SYSTEM
METAL GUTTER &
DOWNSPOUT SYSTEM
BLAST RESISTANT
ALUMINUM / GLASS
CURTAIN WALL SYSTEM
JUNE 2008
ELEV + 121’-2"
TOB
ELEV + 111’-2"
TOB
A-310 A-311
ELEV + 121’-2"
TOB
B 1/8"=1’-0"
BUILDING SECTION
BUILDING SECTION
1/8"=1’-0"
A C 1/8"=1’-0"
BUILDING SECTION
VEST CORR
TRAINING RM BREAK RM
1 2 4 5 6 7 8 10 11 13 14 15 16 17 18 19 20
A-310
ASSIST
CHIEF OFC
CORR
PROTECTIVE
CLOTHING PHYSICAL FITNESS CORR CORR
STANDING SEAM METAL
ROOF OVER RIGID
INSULATION ON PRE-ENGINEERED
COLD FORMED METAL TRUSSES
1 2 4 5 6 7 8 10 11 13 1 2 4 5 6 7 8 10 11 13
ELLINGTON FIELD - HOUSTON, TEXAS
REPLACE FIRE STATION
TEXAS AIR NATIONAL GUARD
N CAMARGO TC ORLOWSKI
ARCHITECTURAL
A-301
BUILDING SECTIONS
A310
A310
A311
A311
CORR
APPARATUS BAYS
APPARATUS BAYS
MODULAR BRICK VENEER, TYP
30"H PRECAST
CONCRETE PANEL
CORR CORR
APP
BAYS
ALUMINUM WINDOW AT RECESSED
ROOF DORMER BEYOND, TYP
FIN FLR
ELEV +99’-6"
APP BAYS FIN FLR
FIN FLR FIN FLR
ELEV + 111’-2"
TOB
ELEV + 111’-2"
TOB
ELEV + 121’-2"
TOB
ELEV + 116’-6"
TOB
FIXED GLASS TRANSOM;
SEE WINDOW SCHED
ELEV + 116’-6"
TOB
FIXED GLASS CLERESTORY AT RECESSED
DORMER; SEE WINDOW SCHEDULE
FIXED GLASS CLERESTORY AT RECESSED
DORMER; SEE WINDOW SCHEDULE
STANDING SEAM METAL ROOF OVER
RIGID INSUL ON PRE-ENGINEERED
COLD FORMED METAL TRUSSES, TYP
STANDING SEAM METAL ROOF OVER
RIGID INSUL ON PRE-ENGINEERED
COLD FORMED METAL TRUSSES, TYP
STANDING SEAM METAL ROOF OVER
RIGID INSUL ON PRE-ENGINEERED
METAL TRUSSES, TYP
LIGHTWEIGHT CONC OVER
METAL ROOF DECK; 1/4:12 TYP
ELEV 100’-0"
ELEV 100’-0" ELEV 100’-0"
CERT OFC
AJ VANHOOSER
WATERPROOF MEMBRANE
ON LIGHTWEIGHT CONC
OVER METAL ROOF DECK
FWJH059032
JUNE 2008
S c a l e
F o r
M i c r o f i l m i n g
I n c h e s
M i l l i m e t e r s
no. date revisionby
191 1615141312111098765432 17 18
N
M
L
K
J
I
H
G
F
E
D
C
B
A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
FILENAME: PLOT DATE: PLOT TIME:dn10a301_339673.dgn 6/30/2008 6:17:28 PM
3001 PGA BOULEVARD - SUITE 300
PALM BEACH GARDENS, FLORIDA
(561) 904-7400 (561) 904-7401 (FAX)
EB0000072 AAC001992 LC26000188
FINAL SUBMITTAL
F
BUILDING SECTION
BUILDING SECTION
1/8"=1’-0"
ED
1/8"=1’-0"
BUILDING SECTION
ELLINGTON FIELD - HOUSTON, TEXAS
REPLACE FIRE STATION
TEXAS AIR NATIONAL GUARD
N CAMARGO TC ORLOWSKI
ARCHITECTURAL
A-302
BUILDING SECTIONS
A-311
ELEV + 121’-2"
TOB
MODULAR BRICK VENEER, TYP
ELEV +99’-6"
APP BAYS FIN FLR
A-311
A-501
A-501
A-501
A-501
A-312
ELEV + 116’-6"
TOB
ELEV 101’-6"
ALARM CTRL RM FIN FLR
10 10
A-312
STANDING SEAM METAL
ROOF OVER RIGID
INSULATION ON PRE-ENGINEERED
COLD FORMED METAL TRUSSES, TYP
STANDING SEAM METAL
ROOF OVER RIGID
INSULATION ON PRE-ENGINEERED
COLD FORMED METAL TRUSSES, TYP
BLAST RESISTANT
CURTAINWALL SYSTEM
AJ VANHOOSER
TRAINING ROOM LOBBY VEST
OVERHEAD SECTIONAL
DOOR, TYP
ELEV 100’-0"
FIN FLR
JANITORCORBUNK RMBUNK RM CORCOR
MEN’S
RESTROOM
ALARM CONTROL
ELEV + 124’-6"
TOB
STANDING SEAM METAL
ROOF OVER RIGID
INSULATION ON PRE-ENGINEERED
COLD FORMED METAL TRUSSES, TYP
MECH ROOM CIR LOCKERS MEN’S RESTROOM
OAI, REFER TO
MECH DWGS
ELEV + 11’-2"
TOB
A
A-301A-301
B
GWB CEILING ATTACHED TO
UNDERSIDE OF TRUSSES
FWJH059032
A-503
BLAST RESISTANT WINDOW
@ RECESSED DORMER, TYP
JUNE 2008
S c a l e
F o r
M i c r o f i l m i n g
I n c h e s
M i l l i m e t e r s
no. date revisionby
191 1615141312111098765432 17 18
N
M
L
K
J
I
H
G
F
E
D
C
B
A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
FILENAME: PLOT DATE: PLOT TIME:dn10a302_339673.dgn 6/30/2008 6:18:16 PM
3001 PGA BOULEVARD - SUITE 300
PALM BEACH GARDENS, FLORIDA
(561) 904-7400 (561) 904-7401 (FAX)
EB0000072 AAC001992 LC26000188
FINAL SUBMITTAL
JUNE 27, 2008
R P N M L K J I H G F E D
W V U T S R P N M L K J I H G F E D C B A
1 2 3 4 5 6 7 8 9 10 11
3/8"=1’-0"3/8"=1-0"
3/8"=1-0"
VESTIBULE
CERT. OFF
APPARATUS BAY
ELLINGTON FIELD - HOUSTON, TEXAS
REPLACE FIRE STATION
TEXAS AIR NATIONAL GUARD
N CAMARGO TC ORLOWSKI
ARCHITECTURAL
WALL SECTIONS
A-310
CONTINUOUS METAL FLASHING, TYP
3/8"=1-0"
ASST CHIEF OFC
CORR
CORR
TRAINING ROOM
BRICK VENEER BEYOND
LIGHTWEIGHT CONC OVER
METAL ROOF DECK
ALUM FRAME/TEMPERED GLASS VISION PANEL
SUSPENDED ACOUSTIC CEILING SYSTEM
WOOD CHAIR RAIL; SEE INT ELEV
4" NOMINAL BRICK VENEER W/
HORIZONTAL JOINT REINFORCEMENT
AT 16" OC VERTICALLY
SUSP ACOUSTIC CEILING
METAL STUD PARTITION; SEE WALL TYPES
ELEV +99’-6"
APP BAYS FIN FLR
TOB
METAL STUD PARTITION; SEE WALL TYPES
METAL STUD PARTITION; SEE WALL TYPES
6"H BASE; SEE FINISH SCHED
PRE-ENG METAL TRUSS
FIN FLR
TOB
FIN FLR
TOB
FIN FLR
TOB
6"H BASE; SEE FINISH SCHED
OVERHEAD SECTIONAL DOOR
CONC BEAM
ROOF DRAINS
16X8 STEEL BEAM
STEEL BEAM
STEEL BEAM
STEEL BEAM
ALUM GUTTER/ DOWNSPOUT, TYP
32"H PRECAST CONC PANEL
MORTARED TO 4" CMU OVER
INSULATED METAL STUD PARTITION
W/MASONRY TIES @ 16" OC VERTICALLY
ELEV +100’-0"ELEV +100’-0"
ELEV +100’-0"
ELEV +111’-2"ELEV +111’-2"
ELEV +121’-2"
STANDING SEAM METAL ROOF; 1:12 SLOPE
@ DORMER RECESS
METAL STUD PARTITION; SEE WALL TYPES
5/8" GWB ON METAL STUDS
PRE-ENGINEERED METAL TRUSSES
5/8" GWB ON METAL STUDS
/4 d
1 1
WALL SECTION @ SOUTH ENTRANCE WALL SECTION @ CERTIFICATION OFFICE
WALL SECTION @ APPARATUS BAYWALL SECTION @ TRAINING ROOM
WINDOW CONDITION TYP @ MAIN BLDG EXTERIOR WINDOWS
A-501
A-501
A-502
A-502
A-502
A-502
A-502
A-501
A-502
A-501
A-502
A-501
A-502
A-502
A-502
A-502
A-501
AJ VANHOOSER
44.5%%d
48" H x 32" W x 1-1/2"
PRECAST CONC PANEL,
ATTACHED TO CMU BLOCK
WITH GALVANIZED BRICK TIES
1 1/2" RIGID THERMAL INSULATION
ON 8" CMU
CONCRETE TIE BEAM
GRADE
PERFORATED METAL SOFFIT
METAL GUTTER
METAL DOWNSPOUT
PERFORATED METAL SOFFIT
AIR RETURN DUCT,
REFER TO MECH DWGS
A312
A312
THERMAL BARRIER:
INSULATED METAL STUD WITH EXT GRADE
SHEATHING IN BOTH SIDES
THERMAL BREAK:
INSULATED METAL STUD WITH EXT
GRADE SHEATHING IN BOTH SIDES
FWJH059032
BRICK SOLDIER COURSE, TYP
BRICK SOLDIER COURSE, TYP
BRICK VENEER OVER INSULATED
METAL STUD PARTITION W/ BRICK
TIES @ 16" OC VERTICALLY AND 2"
AIR GAP
BRICK VENEER OVER 8" CMU W/
BRICK TIES @ 16" OC VERTICALLY
VENTED SOFFIT, STUCCO ON GALV METAL LATH
ELEV +118’-6 3/8"
STANDING SEAM METAL ROOF OVER 5/8" SHEATHING
AND R-30 RIGID INSUL MECH FASTENED TO STEEL
DECK
STANDING SEAM METAL ROOF OVER 5/8"
SHEATHING AND R-30 RIGID INSUL MECH
FASTENED TO STEEL DECK
STANDING SEAM METAL ROOF OVER 5/8"
SHEATHING AND R-30 RIGID INSUL MECH
FASTENED TO STEEL DECK
STANDING SEAM METAL ROOF OVER
5/8" SHEATHING AND R-30 RIGID INSUL
MECH FASTENED TO STEEL DECK
ALUM / GLASS BLAST RESISTANT
STORE FRONT SYSTEM
ALUM / GLASS BLAST RESISTANT
WINDOW SYSTEM
ALUM/ BLAST RESISTANT FIXED GLASS
CLERESTORY WINDOW AT RECESSED DORMER
JUNE 2008
S c a l e
F o r
M i c r o f i l m i n g
I n c h e s
M i l l i m e t e r s
no. date revisionby
191 1615141312111098765432 17 18
N
M
L
K
J
I
H
G
F
E
D
C
B
A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
FILENAME: PLOT DATE: PLOT TIME:dn10a310_339673.dgn 6/30/2008 6:19:06 PM
3001 PGA BOULEVARD - SUITE 300
PALM BEACH GARDENS, FLORIDA
(561) 904-7400 (561) 904-7401 (FAX)
EB0000072 AAC001992 LC26000188
FINAL SUBMITTAL
REPLACE FIRE STATION
TEXAS AIR NATIONAL GUARD
ARCHITECTURAL
A-311
N CAMARGO TC ORLOWSKI
3/8"=1’-0"
APPARATUS BAYS
APPARATUS BAYS
CORRIDOR
BREAK ROOM
PROTECTIVE CLOTHING
2" AIR GAP
SUSP ACOUSTIC CEILING
4" BASE; SEE FINISH SCHED
4" BASE; SEE FINISH SCHED
GLASS BLOCK CLERESTORY
5/8" GWB ON METAL STUDS
SUSP ACOUSTIC CEILING
METAL STUD PARTITION; SEE WALL TYPES
2 HR RATED CONSTRUCTION JOINT
BRICK VENEER W/HORIZONTAL JOINT
REINFORCEMENT @ 16" OC VERTICALLY
BRICK VENEER W/ ADJUSTABLE
VENEER ANCHORS
BRICK VENEER W/ ADJUSTABLE
VENEER ANCHORS
BRICK VENEER W/HORIZONTAL JOINT
REINFORCEMENT @ 16" OC VERTICALLY
BATT INSULATION
BATT INSULATION
METAL STUDS
METAL STUDS
STEEL BEAM
CONC BEAM
CONC BEAM
STEEL BEAM
STEEL BEAM
STEEL BEAM
STEEL BEAM
STEEL BEAM
TOB
MAIN BLDG FIN FLR
APP BAYS FIN FLR
TOB
ELEV +100’-0"
ELEV +116’-6"
ELEV +121’-2"
ELEV +99’-6"
APP BAYS FIN FLR
ELEV +99’-6"
ELEV +116’-8"
TOB
ELEV +121’-2"
TOB
3/8
3/8
3/8
3/8
12 13
APPARATUS BAYS
CORRIDOR
ELEV +121’-2"
TOB
CONC BEAM
3/8
STEEL BEAM
APP BAYS FIN FLR
ELEV +99’-6"
A-501
A-501
A-501 A-501
A-503 A-503
A-501
A-501
A-501 A-501
A-503
A-501
A-501
WALL SECTION @ APPARATUS BAY OH DOORSWALL SECTION @ BREAK ROOM
WALL SECTION @ APPARATUS BAY PERSONNEL ENTRANCE WALL SECTION @ MAIN BLDG & APPARATUS BAY SEPARATION
A-501
1 12
APP BAYS FIN FLR
ELEV +99’-6"
APPARATUS BAYS
ELEV +121’-2"
TOB
A-503
SIM
AJ VANHOOSER
ROOF CONSTRUCTION JOINT
ROOF CONSTRUCTION JOINT
A-503
A-503
CONC BEAM
OVERHEAD SECTIONAL DOOR
BRICK VENEER W/HORIZONTAL JOINT
REINFORCEMENT @ 16" OC VERTICALLY
PERFORATED METAL SOFFIT
METAL JOIST
1" RIGID INSULATION
METAL TRUSSES
CONC BEAM
PERFORATED
METAL SOFFIT
METAL TRUSSES
STEEL BEAM
PERFORATED METAL
SOFFIT
PERFORATED
METAL SOFFIT
METAL JOISTS
METAL TRUSSES
MOISTURE RESISTANT
GWB CEILING
BRICK VENEER W/HORIZONTAL
JOINT REINFORCEMENT
@ 16" OC VERTICALLY
PERFORATED METAL SOFFIT
PRECAST CONCRETE PANEL
BASE ATTACHED TO CONCRETE
BLOCK
CMU WALL
1" RIGID INSULATION
CMU WALL
CMU WALL
THERMAL BARRIER:
INSULATED METAL STUD WITH
EXT GRADE SHEATHING IN BOTH SIDES
THERMAL BARRIER:
INSULATED METAL STUD WITH
EXT GRADE SHEATHING IN BOTH SIDES
THERMAL BARRIER:
INSULATED METAL STUD WITH
EXT GRADE SHEATHING IN BOTH SIDES
THERMAL BARRIER:
INSULATED METAL STUD WITH
EXT GRADE SHEATHING IN BOTH SIDES
FWJH059032
BRICK SOLDIER
COURSE, TYP
AIR / VAPOR BARRIER WALL
MEMBRANE ON 5/8" EXTERIOR
GRADE SHEATHING
AIR / VAPOR BARRIER WALL
MEMBRANE ON 5/8" DENSGLASS
GOLD SHEATHING
SELF -ADHERING SHEET WATERPROOFING
MEMBRANE OVERLIGHTWEIGHT CONC ON
METAL ROOF DECK
SELF ADHERING SHEET
WATERPROOFING
MEMBRANE ON LIGHT WEIGHT
CONC OVER METAL DECK
SELF-ADHERING
WATERPROOFING
MEMBRANE
ON LIGHT WEIGHT
CONC OVER
METAL DECK
BRICK SOLDIER
COURSE, TYP
BRICK SOLDIER COURSE, TYP
SEE NOTE 1 SEE NOTE 1
SEE NOTE 1
NOTE 1:
PROVIDE 1’-0" x 2’-0" 80 MIL WALKABLE
MEMBRANE BELOW OF EACH DOWNSPOUT
AT FLAT ROOF.
ELEV +100’-0"
FIN FLR
STANDING SEAM METAL ROOF
OVER 5/8" SHEATHING AND R-30
RIGID INSULATION MECH
FASTENED TO STEEL DECK
STANDING SEAM METAL ROOF
OVER 5/8" SHEATHING AND R-30
RIGID INSULATION MECH
FASTENED TO STEEL DECK
STANDING SEAM METAL ROOF OVER 5/8"
SHEATHING AND R-30 RIGID INSULATION
MECH FASTENED TO STEEL DECK
STANDING SEAM METAL ROOF OVER 5/8"
SHEATHING AND R-30 RIGID INSULATION
MECH FASTENED TO STEEL DECK
STANDING SEAM METAL ROOF OVER 5/8"
SHEATHING AND R-30 RIGID INSULATION
MECH FASTENED TO STEEL DECK
STANDING SEAM METAL ROOF OVER 5/8"
SHEATHING AND R-30 RIGID INSULATION
MECH FASTENED TO STEEL DECK
OVER METAL TRUSSES
JUNE 2008
S c a l e
F o r
M i c r o f i l m i n g
I n c h e s
M i l l i m e t e r s
no. date revisionby
191 1615141312111098765432 17 18
N
M
L
K
J
I
H
G
F
E
D
C
B
A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
FILENAME: PLOT DATE: PLOT TIME:dn10a311_339673.dgn 6/30/2008 6:19:51 PM
3001 PGA BOULEVARD - SUITE 300
PALM BEACH GARDENS, FLORIDA
(561) 904-7400 (561) 904-7401 (FAX)
EB0000072 AAC001992 LC26000188
FINAL SUBMITTAL
REPLACE FIRE STATION
TEXAS AIR NATIONAL GUARD
ARCHITECTURAL
A-312
1 2
WALL SECTION @ MAIN ENTRANCE
MAIN BLDG FIN FLR
ELEV +100’-0"
CONTROL RM FIN FLR
ELEV +101’-6"
WALL SECTION @ ALARM CONTROL ROOM
STEEL BEAM
ELEV +116’-8"
TOB
PREFINISHED METAL THROUGH
WALL FLASHING
BRICK VENEER W/ HORIZONTAL
REINFORCEMENT AT 16" OC
VERTICALLY, TYP
PREFINISHED METAL COPING
DECORATIVE ALUM LOUVER
STEEL BEAM
PREFINISHED METAL COPING
A-501
A-501
A-501
SIM
SIM
AJ VANHOOSER
MOTORIZED ROLLER WINDOW
SHADE, TYP
PTD GWB ON METAL
STUD SOFFIT, TYP
ALARM CONTROL
ROOM
ACOUSTICAL CEILING
TILE
CMU WALL
CONCRETE BEAM
BRICK VENEER BEYOND
A-503
A-503
A-503
A-503
STANDING SEAM METAL ROOF
OVER 5/8" SHEATHING AND R-30
MIN RIGID INSULATION MECH
FASTENED TO STEEL DECK
STANDING SEAM METAL ROOF OVER 5/8"
SHEATHING AND R-30 MIN RIGID
INSULATION MECH FASTENED TO STEEL
DECK
ALUM / GLASS BLAST
RESISTANT STOREFRONT
SYSTEM
STANDING SEAM METAL
ROOF OVER 5/8"
SHEATHING AND R-30 MIN
RIGID INSULATION MECH
FASTENED TO STEEL DECK
STANDING SEAM
METAL ROOF OVER 5/8"
SHEATHING AND R-30
MIN RIGID INSULATION
MECH FASTENED TO
STEEL DECK
STEEL BEAM
BRICK VENEER
W/ADJUSTABLE VENEER
ANCHORS @ 16" OC
VERTICALLY
2" AIR GAP
INSULATED METAL STUD
PARTITION W/ EXTERIOR
WEATHER RESISTANT
BARRIER
INSULATED METAL STUD
PARTITION W/ EXTERIOR
WEATHER RESISTANT BARRIER
A-501
BRICK VENEER OVER 8" CMU
W/ MASONRY TIES @ 16" OC
VERTICALLY
A-502
A-502
A-502
2A
PERFORATED METAL
SOFFIT
S-501
SIM
OPEN
P LAMINATED UPPER
CABINET WITH
ADJUSTABLE SHELVES,
TYP
RAMP RAMP
/2
/4
/4
/4
SPACE FOR
REFRIGERATOR
CERAMIC TILE (CT8)
BACKSPLASH, REFER
TO DET 11 /A-402
SSM (QUARTZ) COUNTER
W/4" BACKSPLASH
CURTAIN WALL STEEL
STRUCT SYSTEM
STUCCO ON METAL LATH ON
WEATHER RESISTANT BARRIER ON
DENSGLASS GOLD SHEATHING ON
METAL STUDS, TYP
ENGINEERED
METAL TRUSSES
METAL TRUSSES
(2) LAYERS WEATHER
RESISTANT BARRIER ON 5/8"
DENSGLASS GOLD SHEATHING
WATERPROOFING MEMBRANE ON
LIGHTWEIGHT CONC OVER
METAL ROOF DECK
METAL JOISTS
PRE-CAST CONC PANEL FULLY
ADHERED (MORTAR + CAST BRICK
TIES) TO CONCRETE WALL
FWJH059032
CONT METAL FLASHING
GROUT
WEEP HOLES @ 24" O.C. MAX
GRADE
1 1/2"=1’-0"
FOOTING DET @ EXT STUD AND WAINSCOAT
1 1/2"=1’-0"
FOOTING DET @ EXT CMU / APPARATUS BAYS
4" CMU BACKING
CONT METAL FLASHING
GROUT
WEEP HOLES @ 24" O.C. MAX
GRADE
RIGID INSULATION
8" CMU WALL
INTERIOR
EXTERIOR
THICKENED EDGE
CONCRETE FOOTING
INTERIOR
EXTERIOR
1"=1’-0"
STANDING SEAM METAL ROOF
CROSS SECTION IN FRONT OF ROOF DORMER
METAL DECK
RIGID INSULATION
WEATHER RESISTANT
BARRIER, TYP
"Z" CLIP FASTENED TO ROOF
PANEL, TYP
CLOSURE STRIP, TYP
WEATHER RESISTANT
BARRIER, TYP
CONT METAL FLASHING
STANDING SEAM
METAL ROOF
PRE-ENGINEERED
GIRDER TRUSS OR
JOIST,REFER TO
STRUCT DWGS
V A
R
IE
S
METAL DECK
STANDING SEAM PANEL
AIR GAP
AIR / VAPOR WALL
MEMBRANE
AIR / VAPOR WALL MEMBRANE
AIR / VAPOR WALL
MEMBRANE
6" INSULATED METAL
STUD WALL, REFER TO
WALL TYPES
VENTED CEILING: STUCCO ON
GALV METAL LATH
S-523
DECORATIVE PRECAST
CONCRETE WAINSCOT PANEL
DECORATIVE PRECAST
CONCRETE WAINSCOT PANEL
ATTACHED TO 4" CMU BACKING
ALUM / GLASS BLAST RESISTANT
CURTAIN WALL WINDOW SYSTEM
JUNE 2008
S c a l e
F o r
M i c r o f i l m i n g
I n c h e s
M i l l i m e t e r s
no. date revisionby
191 1615141312111098765432 17 18
N
M
L
K
J
I
H
G
F
E
D
C
B
A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
FILENAME: PLOT DATE: PLOT TIME:dn10a312_339673.dgn 6/30/2008 6:20:59 PM
3001 PGA BOULEVARD - SUITE 300
PALM BEACH GARDENS, FLORIDA
(561) 904-7400 (561) 904-7401 (FAX)
EB0000072 AAC001992 LC26000188
FINAL SUBMITTAL
JUNE 27, 2008
VENT PIPING
SEE PLUMB.
(2) CONT. BEADS OF
SEALANT
WATERPROOF RIVETS
WITH HEADS SEALED
(SECURE FLASHING TO
METAL ROOFING ONLY)
CONT.
SEALANT,
BOTH SIDES
ROOF
UNDERLAYMENT
MEMBRANE
1 1/2"=1’-0"
VENT THROUGH ROOF DETAIL
CONT. PREFINISHED
METAL FLASHING
COLLAR, COLOR TO
MATCH METAL ROOFING
METAL FLASHING, PAINTED
TO MATCH ADJACENT ROOF
COLOR
MTL ROOF ON 5/8"
SHEATHING AND R-30 RIGID
INSULATION MECHANICALLY
FASTENED TO STEEL DECK
COLD FORMED
TRUSS
M
IN
4"MIN.
8"
METAL ROOF VALLEY TYP DETAIL
NTS
STANDING SEAM
METAL ROOFING
LOCK PANELS PANS TO
ENGAGE VALLEY METAL CENTER RIB 1"
(25 mm) MIN HEIGHT
SLIP SHEET
UNDERLAYMENT OR ICE-DAM
PROTECTION MEMBRANE
ROOF SUBSTRATE
4" MIN
PANEL OVERLAP ONTO
VALLEY METAL FLANGE
VALLEY CLIP MIN 2
FASTENERS PER CLIP
(APPROX. 2" WIDE) BEND
CLIP BACK OVER TO COVER
FASTENERS
1/4" = 1’-0"
1/4" = 1’-0"
ENTRANCE VESTIBULE AND LOBBY
RM # 101, 102
ALARM CONTROL ROOM
RM # 133
A
ELLINGTON FIELD - HOUSTON, TEXAS
REPLACE FIRE STATION
TEXAS AIR NATIONAL GUARD
A-401
3/8" = 1’-0"
RM # 101, 102
A401
A
B D
C
A
B D
C
GLASS-FRONT
DISPLAY CASE
LOCKABLE STORAGE
GLASS-FRONT
DISPLAY CASE
GLASS-FRONT
DISPLAY CASE
GLASS-FRONT
DISPLAY CASE
LOCKABLE STORAGE
RECESSED
TOE KICK
RECESSED
TOE KICK
ALUM/GLASS
STOREFRONT
ENTRANCE
P LAM SOFFIT W/
DECO REVEALS
MATCHING P LAM
FASCIA PANEL
P LAM SOFFIT W/
DECO REVEALS
MATCHING P LAM
FASCIA PANEL
MATCHING P LAM
FASCIA PANEL
P LAM SOFFIT W/
DECO REVEALS
6"H. CT1 BASE
6"H. CT1 BASE 6"H. CT1 BASE
6"H. CT1 BASE
VWF
VWF VWF VWF
VWF
VWF
VWF
VWF
VWF
VWF
VWF
VWF
ENTRANCE VESTIBULE AND LOBBY ELEVATIONS
3/8" = 1’-0"
ALARM CONTROL ROOM ELEVATION
GENERAL NOTES
ALUM/GLASS
STOREFRONT
ENTRY
ALUM/GLASS
STOREFRONT
ENTRY
1. PROVIDE AND INSTALL CONTINUOUS SEALANT AT CASEWORK
WHERE BACKSPLASH ABUTS COUNTERTOP, AND WALL.
PROVIDE AND INSTALL CONTINUOUS SEALANT WHERE
CASEWORK ABUTS FLOOR SURFACE.
2. ALL FAUCETS SHALL BE ACCESSIBILITY CODE COMPLIANT,
COORDINATE WITH PLUMBING.
3. COORDINATE ALL FINISHES WITH ROOM FINISH SCHEDULE.
4. COORDINATE EQUIPMENT LOCATIONS WITH CONTRACTING
OFFICER PRIOR TO COMMENCING INSTALLATION.
AND INTERIOR ELEVATIONS
ENLARGED PLANS
RECESSED
BULLETIN
BOARD
RECESSED
BULLETIN
BOARD
3’-10"
21’-6"
3’-10"
12’-4"
3’-6"
5’-4"
3’-6"
4’-4"
5’-4"
6’-8"
5’-0"
6’-4"
8’-2"
R 9’-6"
1’-10"
3’-4"
1’-10"
1’-10"
3’-4"
1’-10"
4’-6"
17’-8"
3’-11"
.3
5% d
7"
STRUCT COUNTER
WALL BRACKET
GROMMET, TYP
STEEL COLUMN, REFER
TO STRUCT DWGS
BRICK VENEER, TYP
WINDOW SILL
101’-6"
101’-0" 100’-0"
FL ELEV
FL ELEV
FL ELEV
RAMP
BLAST RESISTANT ALUM/
GLASS CURTAIN WALL
A
RECESSED
FLOOR GRATE
5’-0" x 7’-6" TERRAZO
FLOOR LOGO
COMM RM
12" DEEP TEMPERED
GLASS SHELF, TYP
P LAMINATED WORK SURFACE
WITH HARD WOOD EDGE
ELECTRIC RACEWAY BEYOND
ACOUSTIC CEILING TILE
AJ VANHOOSER
FWJH059032
SLIDING TEMPERED
GLASS DOORS
TEMPERED GLASS-
FRONT DISPLAY CASE
TEMPERED GLASS
FRONT DISPLAY
CASE
FRAMELESS TEMPERED
GLASS DISPLAY CASE
SLIDING DOOR
FRAMELESS
TEMPERED
GLASS DISPLAY
CASE
USAF FIREFIGHTER LOGO DETAIL
N.T.S.
1:
2:
3:
4:
COLOR
COLOR
COLOR
COLOR
LEGEND:
WHITE
BLUE
YELLOW
RED
1 2
JUNE 2008
S c a l e
F o r
M i c r o f i l m i n g
I n c h e s
M i l l i m e t e r s
no. date revisionby
191 1615141312111098765432 17 18
N
M
L
K
J
I
H
G
F
E
D
C
B
A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
FILENAME: PLOT DATE: PLOT TIME:dn10a401_339673.dgn 6/30/2008 6:22:07 PM
3001 PGA BOULEVARD - SUITE 300
PALM BEACH GARDENS, FLORIDA
(561) 904-7400 (561) 904-7401 (FAX)
EB0000072 AAC001992 LC26000188
FINAL SUBMITTAL
1/4" = 1’-0" RM # 152
KITCHEN
1/4" = 1’-0"
RM # 106
1/4" = 1’-0" RM # 108
WORK ROOM
CERTIFICATION TESTING OFFICE
ELLINGTON FIELD - HOUSTON, TEXAS
REPLACE FIRE STATION
TEXAS AIR NATIONAL GUARD
A-402
N CAMARGO
M KUSSLER
TC ORLOWSKI
FULL-HT SS
BACKSPLASH
3"
3"
1’-6"
1’-6"
2’-0"
3"
EQ
3’-0"
BOTTOM HINGED
FALSE DRAWER
FOR DISPOSAL
SWITCH ACCESS
DISPOSAL
SWITCH BELOW
COUNTERTOP
3" TYP
D
A
B
C
A-402
A-402
A-402
A-402
A
T
Y P
B DC (OPP)
P LAM BASE
CABINETS AND
DRAWERS, TYP
ELECTRICAL
OUTLETS, TYP
E Q
E Q
C L
MELAMINE ADJ
SHELVING, TYP
WIRE PULLS,
TYP
OPEN
ISLAND PLAN
1/2"=1’-0"
KITCHEN
KITCHEN ISLAND ELEVATIONS
1/2"=1’-0"
12118
A
B
F
A-402
A
B
C
0 4 8 12
1/4"=1’-0"
0 2 4 6
1/2"=1’-0"
3/8"=1’-0"
KITCHEN ISLAND ELEVATIONS
2’-10"
4’-6"
2’-0"
10’-10"
5’-0"
5’-5"
1649 C L
6 EQUAL
3 EQUAL
2’-6"
A-402
A
WORK ROOM ELEVATIONS
A B C
C L
2’-2"
1’-10"
1’-10"
1’-9"
5’-5"
CERTIFICATION TESTING OFFICE ELEVATIONS
B
A
WINDOW, SEE
SCHEDULE
REFRIGERATOR,
TYP
5/8" GWB ON BOTH SIDES
OF 3-5/8" MTL STUDS
@16" OC (TYP BELOW
COUNTER), ALIGN WITH
EDGE OF WALL
DINING
KITCHEN
12’-10"
ROOM
WORK
OFF.
CERT.
A-402
B
1’-0" RADIUS
1/2" WIDE GWB
REVEAL (3 SIDES OF
WALL), PTD BLACK
PAINTED
PAINTED
3"
1 1/2 "
BASE, SEE SCHED
1x STAINED WOOD TRIM
CAP W/ CLEAR LACQUER
PROTECTANT
2’-6"
BASE, TYP
DOOR AND
FRAME BEYOND
(TYP), SEE
SCHED
A B
P LAM
BACKSPLASH
BASE, TYP
PAINTED, TYP
PAINTED, TYP
2-1/2" DIA
GROMMET W/
BLACK PVC
SLEEVE (TYP),
CENTERED AT
EACH SPACE
5 EQUAL
FIRE SUPPRESSION
CONTROL CABINET
PTD GWB SOFFIT, TYP
P LAM CABINETS
W/ ADJUSTABLE
SHELVES, TYP
WOOD CAP ON MTL
STUDS @16" OC W/
GWB ON BOTH SIDES
STOP REVEAL (BOTH SIDES)
DOOR AND
FRAME
BEYOND
(TYP), SEE
SCHED
RANGE, SEE EQUIP SCHED
BASE (TYP), SEE FINISH SCHED
1’-10"
PAINTED, TYP
SINK, SEE
EQUIPMENT
PLAN
SINK W/
DISPOSAL, SEE
EQUIPMENT
PLAN
WIRE PULLS, TYP
DRAWER W/ PAINTED
INTERIORS (FALSE DRAWERS
@ SINKS)
3"
1/4" PLYWOOD W/
MELAMINE FINISH
1/4" PLYWOOD W/
MELAMINE FINISH
RECESSED METAL SHELF
STANDARDS (2 PER SIDE)
RECESSED METAL SHELF
STANDARDS (2 PER SIDE)
S E
E E
L
S E
E E
L
S E
E E
L E
V A
T
IO
N
SHELVES: (1) IF CABINET
HEIGHT IS 2’-4" OR LESS, (2)
IF CABINET HEIGHT IS
GREATER THAN 2’-4"
SEE ELEVATIONS FOR
COUNTERTOP AND
BACKSPLASH
2-1/2" APRON (FINISH TO MATCH
CABINET) TO CONCEAL LIGHT
FIXTURE WHERE SCHEDULED
SOLID SURFACE COUNTER TOPS AND BACKSPLASH
WHERE INDICATED ON PLANS AND ELEVATIONS
1/2"=1’-0"
TYP CASEWORK SECTION
A B
PROVIDE BACKSPLASH AT
SIDEWALLS, TYP
GENERAL NOTES
A-402
TYP SIM
A-402
A-402
SIM
A-402
SIM
0 2 4 6
2’-0"
U.N.O.
2" U.N.O. 1’-0" U.N.O.
2 EQUAL
3 EQUAL
1’-6" CLR
6’-0"
1’-0"
RANGE HOOD; HOOD SHALL
OVERHANG 6" BEYOND COOKING
SURFACE, EA END
6"
152 6"
1’-6"
M
IN
M A
X
2x WOOD BLOCKING
W/ P LAM FINISH
3" PRIVACY PANEL
(P LAM FINISH)
P LAM SUPPORT
BELOW
P LAM BACKSPLASH TO
BOTTOM OF REVEAL
1-1/2" COUNTER SUPPORT
(P LAM FINISH)
2x WOOD BLOCKING
W/ P LAM FINISH
BASE CABS: 3/4" PLYWOOD
W/ P LAM @ ALL EXPOSED
SURFACES (TYP) MELAMINE
INTERIORS
BASE CABS: 3/4" PLYWOOD
W/ P LAM @ ALL EXPOSED
SURFACES (TYP) MELAMINE
INTERIORS
PT 2"x WD CONT BLOCKING
(TYP)
3/4" PLYWOOD ADJ SHELF
W/ P LAM FINISH @ ALL
EXPOSED SURFACES
1"x WD BLOCKING CONT
TOP AND BOTTOM
P LAM UPPER AND
LOWER CABINETS
W/ ADJUSTABLE
SHELVES, TYP
AND INTERIOR ELEVATIONS
ENLARGED PLANS
PANTRY
CABINET (3’-0" W
x 2’-0" D x 7’-0")
BASE CAB W/
LAZY SUSAN
BASE CAB W/
LAZY SUSAN
3/4" WORK
SURFACE (P LAM
FINISH) W/
BULLNOSE EDGE
BASE CAB W/
LAZY SUSAN
UNDER-COUNTER
ICE-MAKER
COMMERCIAL
DISHWASHER
BASE CAB W/
LAZY SUSAN
SSM (QUARTZ)
COUNTER W/4"
BACKSPLASH,
TYP3
BASE CAB W/
LAZY SUSAN
BASE CAB W/
LAZY SUSAN
SSM (QUARTZ)
COUNTER W/ 4"
BACKSPLASH, TYP
1. PROVIDE AND INSTALL CONTINUOUS SEALANT AT CASEWORK
WHERE BACKSPLASH ABUTS COUNTERTOP AND WALL.
PROVIDE AND INSTALL CONTINUOUS SEALANT WHERE
CASEWORK ABUTS FLOOR SURFACE.
2. ALL FAUCETS SHALL BE ACCESSIBILITY CODE COMPLIANT,
COORDINATE WITH PLUMBING.
3. COORDINATE ALL FINISHES WITH ROOM FINISH SCHEDULE.
TILE
BACKSPLASH,
TYP, W/ 1" CAP
TRIM WHERE
SHOWN
1-1/2" COUNTER
(P LAM FINISH),
TYP
A-402
PANTRY CABINET
PTD GWB SOFFIT, TYP
3’-0"
P LAM PANTRY
CABINET W/
ADJUSTABLE
SHELVES, TYP
COMMERCIAL
REFRIGERATOR
WALL BEYOND
PAINTED, TYP
WINDOW BEYOND
(TYP), SEE
SCHEDULE
SSM (QUARTZ)
COUNTERTOP, TYP
SSM (QUARTZ)
COUNTERTOP, TYP
A-402
BACKSPLASH TILE PATTERN
1"=1’-0"
CT9, TYP
CT8, TYP
1" COORDINATING
TRIM (CT8) WHERE
SHOWN
SSM (QUARTZ)
BACKSPLASH
SS BACKSPLASH
AT RANGE
FWJH059032
5’-6"
JUNE 2008
S c a l e
F o r
M i c r o f i l m i n g
I n c h e s
M i l l i m e t e r s
no. date revisionby
191 1615141312111098765432 17 18
N
M
L
K
J
I
H
G
F
E
D
C
B
A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
FILENAME: PLOT DATE: PLOT TIME:dn10a402_339673.dgn 6/30/2008 6:23:49 PM
3001 PGA BOULEVARD - SUITE 300
PALM BEACH GARDENS, FLORIDA
(561) 904-7400 (561) 904-7401 (FAX)
EB0000072 AAC001992 LC26000188
FINAL SUBMITTAL
| 025-dn10a160_339673-001 |
| 026-dn10a201_339673-001 |
| 027-dn10a202_339673-001 |
| 028-dn10a301_339673-001 |
| 029-dn10a302_339673-001 |
| 030-dn10a310_339673-001 |
| 031-dn10a311_339673-001 |
| 032-dn10a312_339673-001 |
| 033-dn10a401_339673-001 |
| 034-dn10a402_339673-001 |
File details come from the government source that posted it. Updated .