57594 Door schedule Satcom / Landstuhl: WSOC Building As of 11/29/2012 b (chanched 01/29/2013)
Specs Item Room name / Room
No.
Door
No.
Surface, color
Building structure Remarks
W H
O p e n i n g c a n b
Fire rating tight-closing + self closing
(DS-s), smoke-rated (RS), fire-protection (T30/T90)
Burglar rated
(WK 1-6),
sound-rated Rw,P(dB)*
Material:
aluminum/glass, wood-glass, steel Door wing
Dreh-richtung
DIN, passive leaf with underline
Swing door (PT), passive+ active wing (SF), passive side parts (FS), transom window
(OL), Side glazing (SV), glass section in door leaf (GA), ventilation opening (LU)
Door dimension
W*H
U-frame
Corner frame (C)
Block frame
Frame (R)
Counter frame (G)
Frame material
Steel (S)
Aluminum (Al)
Wood (W)
Increased sound rating (door with double lip seal)
Opening width of frame in mm, shadow gap
(SN)
Frame and door leaf
Door seal / bottom clearance Type of lock
Restroom lock (WC-
S) profile cylinder (PC), dummy cylinder (DC)
Overhead door closer, door coordinator
(make IAW specs), opposite hinge side (bg)
Electric door opener
Motorized bolt
Magnet (retaining function, with integrated smoke detector)
Magnetic contact
(quantity)
Escape route terminal
Card reader, access control
Door handle (DH) on both sides (make IAW specs)
Other hardware equipment:
door handle (TD) / long bar handle / pushbar / short bar handle / knob
(make IAW specs)
Hinge type
(make IAW specs)
Concrete wall (CW), precast concrete element
(BC), aerated concrete
(AC), masonry wall (MW), plasterboard wall (PW), prefab wall (EW), glass (G)
1 2.16.40 Vestibule (exterior door) 100 100-01 4.035 5.700 al/glass 2-wing L/R SF/OL 2.01*2.135 R Al no --- E6/EV1 yes PC-prepare PC-prepare yes / bg no no no 2 no no no Long handle bar, hinge side inside/outside
BC
Three-part with transom window, force protection
2 2.20.500 Entrance hall (to vestibule 100) 101 101-01 4.010 2.760 --- WK3 al/glass 2-wing L/R SF/OL 2.01*2.135 R Al no --- E6/EV1 yes PC-prepare PC-prepare yes / bg yes no no 2 yes yes no Long handle bar, hinge side inside/outside PW
Three-part with transom window, intercom station with video surveillance
3 2.20.510 Entrance hall (to corridor 111) 101 101-02 1.550 3.100 --- --- al/glass 2-wing L/R OL activ leaf
1,00*2,135 R Al no --- E6/EV1 automatic PC-prepare PC yes / bg no no no no no no DH / DH no
AC
Passive wing with shoot bolt
4 2.17.10 Main administration (from corridor 111) 102 102-01 1.010 2,760 DS-s 32 dB wood-glass 1-wing R OL 1.01*2.135 U Al no 200 RAL9010 automatic PC-prepare PC ja no no no no no no DH/DH +DH no AC door wing high splittet
5 2.17.20 Visitors (from corridor 111) 103 103-01 1.010 2,760 DS-s 32 dB wood-glass 1-wing R OL 1.01*2.135 U Al no 200 RAL9010 automatic PC-prepare PC ja no no no no no no DH / DH no AC ---
6 2.17.110 ISGT (from Room 105) 104 104-01 1.010 2.135 --- --- wood 1-wing L --- 1.01*2.135 U Al no 125 RAL9010 automatic PC-prepare PC no no no no no no no DH / DH no GK ---
7 2.17.10 ISGT (from Corridor 111) 104 104-02 1.010 2,760 DS-s 32 dB wood-glass 1-wing R OL 1.01*2.135 U Al no 200 RAL9010 automatic PC-prepare PC ja no no no no no no DH / DH no AC ---
8 2.17.10 CO (from Corridor 111) 105 105-03 1.010 2,760 DS-s 32 dB wood-glass 1-wing R OL 1.01*2.135 U Al no 200 RAL9010 automatic PC-prepare PC ja no no no no no no DH / DH no AC ---
9 2.17.80 Test skills (from Corridor 111) 106 106-01 1.010 2.135 DS-s 32 dB wood 1-wing L --- 1.01*2.135 U Al no 200 RAL9010 automatic PC-prepare PC ja no no no no no no DH / DH no AC ---
10 2.17.80 PLTN SGT (from Corridor 111) 107 107-01 1.010 2.135 DS-s 32 dB wood 1-wing L --- 1.01*2.135 U Al no 200 RAL9010 automatic PC-prepare PC ja no no no no no no DH / DH no AC ---
11 2.17.80 PLTN SGT (from Corridor 111) 108 108-01 1.010 2.135 DS-s 32 dB wood 1-wing L --- 1.01*2.135 U Al no 200 RAL9010 automatic PC-prepare PC ja no no no no no no DH / DH no AC ---
12 2.17.80 XO (from Corridor 111) 109 109-01 1.010 2.135 DS-s 32 dB wood 1-wing L --- 1.01*2.135 U Al no 200 RAL9010 automatic PC-prepare PC ja no no no no no no DH / DH no AC ---
13 2.17.80 Office supply (from Corridor 111) 110 110-01 1.010 2.135 DS-s 32 dB wood 1-wing L --- 1.01*2.135 U Al no 200 RAL9010 automatic PC-prepare PC ja no no no no no no DH / DH no AC ---
14 2.16.50 Corridor 111 (exterior door) 111 111-01 1.800 3.250 al/glass 1-wing R SF/OL 1.00*2.135 R Al no --- E6/EV1 yes panic E
PC-prepare yes / bg yes no no 1 no yes no mechatronic pushbar/knob BC force protection
2.17.160
Conference room (to Corridor 115) 112 112-01 1.010 2.135 DS-s 37 dB wood-glass 1-wing L --- 1.01*2.135 U Al yes 200 RAL9010 automatic PC-prepare no ja yes no no 1 no yes no mechatronic pushbar/knob AC ---
2.17.160
Conference room (to Corridor 115) 112 112-02 1.010 2.135 DS-s 37 dB wood-glass 1-wing R --- 1.01*2.135 U Al yes 200 RAL9010 automatic PC-prepare no ja yes no no 1 no yes no mechatronic pushbar/knob AC ---
17 2.20.400 Weapons 113 (to Room 110) 113 113-01 1.220 2.135 --- GSA class V steel 1-wing R --- 1.22*2.11 C S no 250 primed --- XO 9 PC no no no no 1 no yes DH / DH viewer CW Hirsch alarm
18 2.17.50 NBC (to Room 110) 114 114-01 1.510 2.135 --- --- wood 1-wing L SV 1.01*2.135 U Al no 125 RAL9010 --- PC-prepare PC no no no no no no no DH / DH --- PW ---
2.20.520
Corridor 115 (to Room 111) 115 115-01 1.550 3.100 RS --- al/glass 2-wing L/R
OL
activ leaf
1,00*2,135 R Al no
E6/EV1
automatic panic E BZ yes / bg no no no no no no
DH / DH
no AC
Passive wing with shoot bolt
20 2.16.50 Corridor 115 (exterior door) 115 115-02 1.800 3.250 al/glass 1-wing R SF/OL 1.00*2.135 R Al no --- E6/EV1 automatic panic E PC-prepare yes / bg yes no no 1 no yes no mechatronic pushbar/knob BF force protection
21 2.17.140 Female locker and restroom (to Corridor 111) 116 116-01 1.010 2.135 --- --- wood 1-wing L --- 1.01*2.135 U Al no 200 RAL9010 no PC-prepare PC yes / bg no no no no no no DH / DH --- AC Moist room, climate class II
22 2.17.140 Male locker and restroom (to Corridor 111) 117 117-01 1.010 2.135 --- --- wood 1-wing R --- 1.01*2.135 U Al no 200 RAL9010 no PC-prepare PC yes / bg no no no no no no DH / DH --- AC Moist room, climate class II
2.17.100
Admin. Office (to Corridor 111) 118 118-01 1.010 2.135 --- --- wood 1-wing R --- 1.01*2.135 U Al no 200 RAL9010 no PC-prepare
PC no yes no no 1 no yes no
Long handle bar, hinge side inside/outside BF ---
24 2.17.170 Electrical equipment room (to Corridor 111) 119 119-01 1.010 2.135 T30 --- wood 1-wing R --- 1.01*2.135 U Al no 200 RAL9010 no PC-prepare PC yes / bg no no yes no no no DH / DH --- AC Opening 170°
25 2.17.10 Fitness (from Corridor 115) 120 120-01 1.010 2,760 DS-s 32 dB wood 1-wing L OL 1.01*2.135 U Al no 200 RAL9010 automatic PC-prepare PC ja no no no no no no DH / DH --- AC ---
26 2.17.10 Common room (from Corridor 115) 121 121-01 1.010 2,760 DS-s 32 dB wood 1-wing L OL 1.01*2.135 U Al no 200 RAL9010 automatic PC-prepare PC ja no no no no no no DH / DH --- AC ---
2.20.530
Corridor 122 (to Room 115) 122 122-01 1.550 3.100 T30-RS WK 3 al/glass 2-wing L/R
OL
activ leaf
1,00*2,135 R Al no ---
E6/EV1
automatic panic E PC-prepare yes / bg yes no no 1 no yes no mechatronic pushbar/knob AC passive wing with shoot bolt
28 2.16.50 Corridor 122 (exterior door) 122 122-02 1.800 3.250 al/glass 1-wing R SF/GA/OL 1.00*2.26 R Al no
--- E6/EV1 yes no PC-prepare yes / bg yes no no 1 no yes no Long handle bar, hinge side inside/outside
BC
2.17.180
WSOC OPS (to Corridor 115) 123 123-01 1.010 2.135 T 30 RS 32 dB wood 1-wing R --- 1.01*2.135 U Al no 200 RAL9010 automatic panic E PC yes / bg yes no no 1 no yes no mechatronic pushbar/knob AC ---
30 2.17.90 WSOC OPS (to Corridor 122) 123 123-02 1.010 2.510 --- 32 dB wood-glass 1-wing L OL 1.01*2.135 U Al no 200 RAL9010 automatic panic E no no yes no no 1 no yes no mechatronic pushbar/knob AC ---
31 2.17.40 Training room (to Room 123) 124 124-01 1.010 2.135 --- 37 dB wood 1-wing R --- 1.01*2.135 U Al yes 125 RAL9010 automatic PC-prepare PC no no no no no no no DH / DH --- PW ---
32 2.17.40 Training room (to Room 123) 124 124-02 1.010 2.135 --- 37 dB wood 1-wing L --- 1.01*2.135 U Al yes 125 RAL9010 automatic PC-prepare PC no no no no no no no DH / DH --- PW ---
33 2.17.60 DCOS office (from Room 123) 125 125-01 1.510 2.135 --- 32 dB wood-glass 1-wing L SV 1.01*2.135 U Al yes 125 RAL9010 automatic PC-prepare PC no no no no no no no DH / DH --- PW Interior window
34 2.17.170 Storage (from Room 125) 126 126-01 1.010 2.135 T30 --- wood 1-wing L --- 1.01*2.135 U Al no 200 RAL9010 no PC-prepare PC yes / bg no no no no no no DH / DH --- AC ---
2.17.190
Female restroom (to Corridor 122) 127 127-01 1.010 2.135 --- --- wood 1-wing R --- 1.01*2.135 U Al no 200 RAL9010 bottom clearance WC-S WC-S yes / bg no no no no no no
DH / DH
--- AC Moist room, climate class II
2.17.150
Male restroom (to Corridor 122) 128 128-01 1.010 2.135 --- --- wood 1-wing L --- 1.01*2.135 U Al no 200 RAL9010 bottom clearance WC-S WC-S yes / bg no no no no no no
DH / DH
--- AC Moist room, climate class II
37 2.17.60 Officer in charge (from Room 123) 129 129-01 1.510 2.135 --- 32 dB wood 1-wing R SV 1.01*2.135 U Al yes 125 RAL9010 automatic PC-prepare PC no no no no no no no DH / DH --- PW side glazing
38 2.17.60 OPS NCO (from Room 123) 130 130-01 1.510 2.135 --- 32 dB wood 1-wing L SV 1.01*2.135 U Al yes 125 RAL9010 automatic PC-prepare PC no no no no no no no DH / DH --- PW side glazing
39 2.17.120 OPS AN (from Room 123) 131 131-01 1.010 2.135 --- 32 dB wood 1-wing L --- 1.01*2.135 U Al yes 125 RAL9010 automatic PC-prepare PC no no no no no no no DH / DH --- PW side glazing
40 2.17.60 OPS EQ (from Room 123) 132 132-01 1.510 2.135 --- 32 dB wood 1-wing L SV 1.01*2.135 U Al yes 125 RAL9010 automatic PC-prepare PC no no no no no no no DH / DH --- PW side glazing
2.17.70
COMSEC (to Room 123) 133 133-01 1.010 2.135 --- 32 dB wood 1-wing R SV 1.01*2.135 U Al yes 125 RAL9010 automatic panic E PC yes / bg yes no no 1 no yes no mechatronic pushbar/knob PW ---
2.17.90
Satcom office 1 (from Corridor 122) 134 134-01 1.010 2.135 --- 32 dB wood 1-wing R --- 1.01*2.135 U Al no 200 RAL9010 automatic panic E PC yes / bg yes no no 1 no yes no mechatronic pushbar/knob AC ---
2.17.90
Satcom office 2 (from Corridor 122) 135 135-01 1.010 2.135 --- 32 dB wood 1-wing L --- 1.01*2.135 U Al no 200 RAL9010 automatic panic E PC yes / bg yes no no 1 no yes no mechatronic pushbar/knob AC ---
2.17.90
Satcom operations (from Corridor 122) 136 136-01 1.010 2.135 --- 32 dB wood 1-wing R --- 1.01*2.135 U Al no 200 RAL9010 automatic panic E PC yes / bg yes no no 1 no yes no mechatronic pushbar/knob AC ---
HardwareDoor frameDoor modelUnit size
(element size)
Door type, rating
FF0000WPW Ingenieure
Hochstraße 61
66115 Saarbrücken 1 of 2 as of October 2012
2.20.350
Satcom operations (from Corridor 122) 137 137-01 2.010 2.260 T30-RS --- steel 2-wing L/R --- 2.01*2.260 add. frame
S no 200 galvanized, primed automatic PZ prepare no yes / side yes no no 2 yes yes no
Long handle bar, hinge side inside/outside AC passive wing with shoot bolt
2.20.390
Satcom operations (to Corridor 136) 137 137-02 2.010 2.260 T30-RS 37 dB steel 2-wing L/R --- 2.01*2.260 add. frame
S yes 200 galvanized, primed automatic PZ-prepare PC yes / bg no no no no no no
DH / DH BC
2.20.420
Gas room (from Corridor 122) 137B 137B-01 1.010 2.260 T30-RS steel 1-wing R --- 1.01*2.260 add. frame
S no 200 galvanized, primed automatic
Panic E, hinge side PC both sides no no no 1 no no
DH / DH
AC in F60 wall/glass section
2.20.360
Eqipment (to Room 123) 138 138-01 2.010 2.260 T30-RS 37 dB Steel/glass 2-wing L/R GA 2.01*2.260 add. frame
S yes 250 galvanized, primed automatic PZ-prepare DC yes / bg yes no no 2 no yes
DH / DH
mechatronic pushbar/knob
BC
passive wing with shoot bolt, pressure class 3
2.20.350
Eqipment (to Corridor 122) 138 138-02 2.010 2.260 T30-RS --- steel 2-wing L/R --- 2.01*2.260 add. frame
S no 200 galvanized, primed automatic panic E PC yes / bg yes no no 2 no yes no mechatronic pushbar/knob
AC
passive wing with shoot bolt, pressure class 3
2.20.430
Eqipment (to Room 123) 138 138-03 1.010 2.135 T30-RS 37 dB Steel/glass 1-wing R GA 1.01*2.26 add. frame
S yes 250 galvanized, primed automatic PZ-prepare DC yes / bg no no no no no yes
DH / DH
BF
in F60 wall/glass section pressure class 3
2.20.370
BLK / RED (to Room 138) 139 139-01 2.010 2.260 T30-RS --- steel 2-wing L/R --- 2.01*2.260 add. frame
S no 200 galvanized, primed automatic panic E PC yes / bg yes no no 2 no yes no mechatronic pushbar/knob
BC
passive wing with shoot bolt, pressure class 3
2.20.450
Equipment receiving (from Room 141) 140 140-01 1.000 2.135 --- --- steel 1-wing R --- 1.01*2.135 add. frame
S no 200 galvanized, primed no panic E PZ yes / bg yes no no 1 no yes no mechatronic pushbar/knob AC ---
53 2.16.80 Equipment receiving (exterior door) 140 140-02 1.010 2.135 steel 1-wing R --- 1.01*2.135 add. frame S no ---galvanized, primed yes panic E PC yes / bg yes no no 1 no yes no mechatronic pushbar/knob BC force protection
2.20.340
Equipment receiving (exterior gate) 140 140-03 3.010 3.010 --- --- steel --- --- --- 3.01*3.01 add. frame
S no --- ? --- PZ-prepare PC --- --- --- --- 1 --- --- ---
BC
Roll-up door force protection
2.20.380
Receiving department (from Room 138) 140 140-04 2.010 2.510 T30-RS --- steel 2-wing L/R --- 2.01*2.51 add. frame
S no 250 galvanized, primed automatic panic E PC yes / bg yes no yes 2 no yes no mechatronic pushbar/knob
BC
passive wing with shoot bolt, pressure class 3
2.20.440
PLL storage (to Corridor 111) 141 141-01 1.010 2.135 T30-RS --- steel/glass 1-wing L GA 1.01*2.135 add. frame
S no 200 galvanized, primed automatic panic E PC yes / bg yes no no 1 no yes no mechatronic pushbar/knob AC ---
2.20.380
PLL storage (to Room 138) 141 141-02 2.010 2.51 T30-RS --- steel 2-wing L/R --- 2.01*2.51 add. frame
S no 250 galvanized, primed automatic PC-prepare
PC yes / bg yes no yes 2 no yes
DH / DH BC
passive wing with shoot bolt
58 2.17.80 Janitor's closet (from Corridor 115) 147 147-01 1.010 2.135 DS-s --- wood 1-wing R --- 1.01*2.135 U Al no 200 RAL9010 no PC-prepare PC yes no no no no no no handle / knob AC ---
2.17.130
DCO 1 (from Room 123) 148 148-01 1.010 2.135 --- 37 dB wood 1-wing R --- 1.01*2.135 U Al yes 125 RAL9010 automatic panic E PC yes / bg yes no no 1 no yes no mechatronic pushbar/knob PW ---
2.20.410
Emergency lighting (to Room 138) 151 151-01 1.010 2.135 T30-RS --- steel 1-wing L --- 1.01*2.135 add. frame
S no 200 galvanized, primed automatic PC-prepare
PC yes / bg no no no no no no handle / knob AC ---
2.20.410
PA (to Room 138) 152 152-01 1.010 2.135 T30-RS --- steel 1-wing L --- 1.01*2.135 add. frame
S no 200 galvanized, primed automatic PC-prepare
PC yes / bg no no no no no no handle / knob AC ---
DOOR NUMBER LEGEND: 123-01: * Proof with certificate panic E = panic lock with transit function E
123 = room number
= Änderungen 01 =number of door in the room
FF0000WPW Ingenieure
Hochstraße 61
66115 Saarbrücken 2 of 2 as of October 2012