Architecture.pdf
PDF 20 MB Posted
- Attached to
- Repair and Minor Renovation of Squadron Operations Building 2215 at Mountain Home Air Force Base, Idaho
- Solicitation number
- W912DW19R0028
About this file
This is a synopsis for a proposed federal contract action to provide minor renovation and repair services for Building 2215 at Mountain Home Air Force Base in Idaho. The project scope includes replacing the roof and HVAC system, remodeling restrooms to meet ADA requirements, adding exterior windows and skylights, relocating interior walls, and providing new interior finishes throughout the facility. The contract value is estimated between $5 million to $10 million. The solicitation will be open only to eligible 8(a) small businesses located in Idaho, Oregon, Utah, or Washington, or those with a bona fide branch office in one of those states. The solicitation documents will be available on July 31, 2019 via FBO.
Architecture - Drawings
View the file
Other files
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D e s ig n e d b y
C h e c k e d b y
D ra w n b y
C a d F il e
D a te
P ro je c t
C H
M H
IL
L
S y m b o l
A p p ro v D a te
D e s c ri p ti o n
Drawing Number:
A B C D E F G H
GUNFIGHTERS
HOME OF THE
COMBAT COMMAND
AIR
DEPARTMENT OF
MOUNTAIN HOME AFB.
THE AIR FORCE
MOUNTAIN HOME
AFB
U.S. AIR FORCE
366 CES/CECD
1030 LIBERATOR ST.
MOUNTAIN HOME AFB, ID
83648-5442
E a s t F ro n t S tr e e t
S u it e
A -0
.d g n
S p e c
P ro je c t
B o is e I d a h o
-7
FILENAME: PLOT DATE: PLOT TIME:2019\04\24 4:14:07 PM
SHEET of
/2
/2
F A
C
IL
IT
Y
Q Y
Z H
-8
R E
P A
IR
S
Q U
A D O
P S
C E
R T
IF
IE
D F
IN
A L D
E S
IG
N
5/8" GWB, EA
SIDE.
A
20 GA, 6" MTL
STUD @ 16" O.C.
B
5/8" GWB
20 GA, 3 5/8" MTL
STUD @ 16" O.C.
C
D
3 5/8" 20 GA. MTL
STUDS @ 24" O.C.
"A
IR
G
A P
EXISTING GWB
E
5/8" GWB, EA
SIDE.
F
20 GA, 3 1/2" MTL
STUD @ 16" O.C.
EXTERIOR
INTERIOR
VAPOR RETARDER
OVER WALL STUDS
INFILL
WALL
CMU WALL INFILL
(MATCH EXISTING)
H
5/8" GWB, EA
SIDE.
20 GA, 8" MTL
STUD @ 16" O.C.
J
2" RIGID INSULATION
(R-14)
3 1/2" SOUND BATT
INSULATION (R-13)
5 1/2" SOUND BATT
INSULATION (R-19)
3 1/2" SOUND BATT
INSULATION (R-13)
EXISTING BATT
INSULATIONATION, IF
NOT INSTALLED
ADD 3 1/2" BATT
INSUALTION (R-13)
5/8" GWB W/ 20 GA,
3 5/8" MTL STUD INFILL
(MATCH EXIST)
@ 16" O.C.
BATT INSULATION
(R-13)
3 1/2" SOUND BATT
INSULATION (R-13)
3 1/2" SOUND BATT
INSULATION (R-13)
NOT USED
(2) LAYER 5/8" GWB
EXSITING CMU WALL
NEW CMU TO
MATCH EXISTING
SEE STRUCTURAL
DETAIL ON S-502
AT SIM. PROVIDE
5/8" GWB
TO STEEL DECK ABOVE
WALL TO EXTEND FULL HEIGHT6.
SEALANT
SEALED WITH ACOUSTIC
ALL PENETRATIONS TO BE 5.
TO WALL STUDS
BE FASTENDED SECURLY
BATT INSULATIONATION SHALL 4.
OF ACOUSTICAL SEALANT
IN 2 CONTINUOUS BEADS
AT 32" O.C. MAX. SET TRACK
AND BOTTOM W/ ANCHORS
CONTINUOUS TRACK TOP
AT NEW WALLS, 16 GA. 3.
NEW WALL TRACK
GROUT IN ALL VOIDS ABOVE
FIRE SAFE OR NON-SHRINK2.
METAL STUDS AND GWB
EXISTING WALL SYSTEM IS1.
NOTE:
BATT INSULATION
AT SIM OMIT SOUND
NOTE:
682783
A-001
A L S
O G
L
IO
D D
A L S
O G
L
IO
A R
C H
IT
E C
T U
R A
L
L E
G E
N D A
N D W
A L L T
Y P
E S
G E
N E
R A
L N
O T S S
Y M
B O
L S
CONCRETE
METAL STUD WALL (PLAN)
GYPSUM WALLBOARD
RIGID INSULATION
BATT INSULATION
ACOUSTICAL TILE
PLYWOOD
WOOD, ROUGH NON-CONTINUOUS
WOOD, ROUGH CONTINUOUS
WOOD, FINISHED
CMU WALL (PLAN)
CMU WALL (SECTION)
GROUT
GRANULAR FILL
EARTH OR FINISH GRADE
GENERAL ARCHITECTURAL NOTES ARCH/STRUCT MATERIAL SYMBOLS
SYMBOL LEGEND
INDICATES PAIR OF DOORS
OR
OR
110.50
DIRECTION OF SLOPE DOWN
OR
A
XX101 ROOM IDENTIFIER
DOOR IDENTIFIER
WINDOW IDENTIFIER
LOUVER IDENTIFIER
W-1
A
E
B
C
D
XX-A-301
XXW-1
XXL-1 L-1
INTERIOR ELEVATION INDICATOR
S-1 SIGNAGE IDENTIFIER
ARCHITECTURAL/STRUCTURAL LEGEND
X X
A
SYMBOL LEGEND
X X
A
SPOT ELEVATION INDICATOR (IN FEET)
ELEVATION DATUM (IN FEET)
GRID / COLUMN INDICATOR
EL XX.XX
XXXX
ROOM NAMEROOM NAME
ARCHITECTURAL WALL TYPES (IN SEMI-RECESSED CABINET)
"X" = NUMBER IN SPECIFICATIONS
FIRE EXTINGUISHER
F.EXT-X
INACTIVE
ACTIVE
REQUIRED
POINTERS AS
DIRECTION OF
QUANTITY AND
(IF SHOWN)
INDICATOR
"XX" = FACILITY DOOR LETTER
ROOM NUMBER
682783_2215A-001.dgn
ADDITIONAL NOTES.
REFER TO ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL AND OTHER CATEGORIES OR DRAWINGS FOR
VERIFY ALL ROUGH-IN DIMENSIONS FOR EQUIPMENT PROVIDED IN THIS CONTRACT, OR BY OTHERS.
AT THE BUILDING FACE, OR ON THE SECTION END EXCEPT AS NOTED.
LINE OF EXISTING GRADES, AS SHOWN ON THE BUILDING ELEVATIONS AND SECTIONS ARE APPROXIMATE. THEY ARE
BOTTOM, INTERSECTION, DOOR FRAMES, AND OTHER PENETRATIONS.
AT SOUND INSULATED WALLS, FULL HEIGHT PARTITIONS SHALL BE SEALED BOTH SIDES WITH ACOUSTIC SEALANT: TOP, WALL TO EDGE OF ROUGH OPENING AT CONCRETE WALLS, 8" AT CMU WALLS.
SHALL BE 4-INCHES FROM FACE OF STUD (WALL) TO FACE OF ROUGH OPENING. DIMENSION SHALL BE 6" FROM FACE OF
WHERE DOOR IS LOCATED NEAR CORNER OF ROOM AND IS NOT LOCATED BY DIMENSION ON PLAN OR DETAILS, DIMENSION
REPETITIVE FEATURES ARE NOT DRAWN IN THEIR ENTIRETY AND SHALL BE COMPLETELY PROVIDED AS IF DRAWN IN FULL.
DEPRESSED FLOORS AND CURBS, SEE STRUCTURAL DRAWINGS.
"FLOOR LINE" REFERS TO TOP OF CONCRETE SLABS. FINISH FLOORING IS INSTALLED ABOVE THE FLOOR LINE. FOR
MASONRY, FACE OF STUDS AND FACE OF CONCRETE WALLS.
UNLESS OTHERWISE INDICATED, PLAN DIMENSIONS ARE TO COLUMN GRID ON CENTERLINES, NOMINAL SURFACE OF
K
INSULATION (R-19)
5 1/2" SOUND BATT
STUD @ 16" O.C.
20 GA, 6" MTL
18.
17.
16.
15.
14.
13.
12.
11.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
5/8" GWB
14 149
C F
IL
A N
O W
IC
Z
WEIGHING MORE THAN 31 LBS.
REFER TO S-001 GENERAL STRUCTURAL NOTES FOR ANTI -TERRORISM (AT) BRACING AND SUPPORT REQUIREMENTS FOR EQUIPMENT
REFER TO SHEET A-610 AND A-611 INTERIOR FINISH AND WINDOW SCHEDULES.
REFER TO THE PLUMBING DRAWINGS FOR FLOOR DRAIN LOCATIONS.
VERIFY ACTUAL REQUIRED CLEAR DISTANCES FOR ALL FIXTURES AND EQUIPMENT PRIOR TO CONSTRUCTION.
ACCESSORIES. SEE ALSO SHEET A-401, AND A-402.
PROVIDE BLOCKING AT ALL MILLWORK, CABINETS, WALL MOUNTED EQUIPMENT, FURNITURE, AND TOILET
NOT USED
FOR DOOR SCHEDULES SEE DRAWING A-601 AND A-602.
FOR WINDOW DESCRIPTIONS SEE SPECIFICATION SECTION 08 51 13.
FOR DOOR AND HARDWARE DESCRIPTIONS SEE SPECIFICATION SECTION 08 71 00.
FOR APPLICABLE CODES AND LIFE SAFETY PLAN, SEE DRAWING G-003.
MECHANICAL, ELECTRICAL AND OTHER EQUIPMENT.
FURRING, CURBS, ANCHORS AND INSERTS. PROVIDE ALL BASES AND BLOCKING REQUIRED FOR ACCESSORIES, VERIFY SIZE AND LOCATION OF, AND PROVIDE: REQUIRED OPENINGS THROUGH FLOORS AND WALLS, ACCESS DOORS, LICENSED
ARCHITECT
STATE O F IDAHO
AR-916427
JO HN P. RESEIG H
25Apr 2019 s ig n e d b y
C h e c k e d b y
D ra w n b y
C a d F il e
D a te
P ro je c t
C H
M H
IL
L
S y m b o l
A p p ro v D a te
D e s c ri p ti o n
Drawing Number:
A B C D E F G H
GUNFIGHTERS
HOME OF THE
COMBAT COMMAND
AIR
DEPARTMENT OF
MOUNTAIN HOME AFB.
THE AIR FORCE
MOUNTAIN HOME
AFB
U.S. AIR FORCE
366 CES/CECD
1030 LIBERATOR ST.
MOUNTAIN HOME AFB, ID
83648-5442
E a s t F ro n t S tr e e t
S u it e
A -0
.d g n
S p e c
P ro je c t
B o is e I d a h o
-7
FILENAME: PLOT DATE: PLOT TIME:2019\04\24 4:16:57 PM
SHEET of
/2
/2
F A
C
IL
IT
Y
Z H
-8
R E
P A
IR
S
Q U
A D O
P S
C E
R T
IF
IE
D F
IN
A L D
E S
A-002
A L S
O G
L
IO
D D
A L S
O G
L
IO
A R
C H
IT
E C
T U
R A
L
B
B R
E V
IA
T
IO
S
DOWNSPOUTDS
DOORDR
DIRECTIONDIR
DIMENSIONDIM
DIAMETERDIA
DRINKING FOUNTAINDF
DEMOLITIONDEMO
DELETEDEL
DEGREEDEG
DOUBLEDBL
DEPTH, DEEPD
CLOCKWISE, CASEMENT WINDOWCW
CABINET UNIT HEATERCUH
CENTER, CONTOURCTR
CERAMIC TILE FLOORCTF
CERAMIC TILE BASECTB
CERAMIC TILE, COUNTCT
CASEWORKCSWK
CARPETCPT
CONCRETECONC
COMBINATION, COMBINEDCOMB
COMMONCOM
COLUMNCOL
CONCRETE MASONRY UNITCMU
CLEAR, COLOR, COOLERCLR
COLUMN LINE, CONTRACT LIMIT LINECLL
CEILING HEIGHTCLG HT
CEILINGCLG
CLASSIFICATIONCLASS
CENTER LINE, CLASS, CLOSECL
CONTROL JOINT, CONSTRUCTION JOINTCJ
CIRCLECIR
CORNER GUARDCG
CONTRACTOR FURNISHED OWNER INSTALLEDCFOI
CONTRACTOR FURNISHED CONTRACTOR INSTALLEDCFCI
CERAMICCER
CEMENTCEM
COUNTER CLOCKWISECCW
CEMENTITIOUS BACKER BOARDCBB
CERAMIC BASE, CORNER BEADCB
CAVITYCAV
CEILING ATTENUATION CLASSCAC
CABINETCAB
CARPET AND PADC & P
C
BOTH WAYSBW
BUILT UP ROOFINGBUR
BETWEENBTWN
BASEMENTBSMT
BOTH SIDESBS
BOTTOMBOT
BOTTOM OF STEELBOS
BELOWBLW
BUILT INBLT IN
BUILDINGBLDG
BITUMINOUSBITUM
BELOW FINISHED FLOORBFF
BOTH FACESBF
BOARDBD
BULLETIN BOARD, BASEBOARDBB
BACK TO BACKB/B
ACOUSTICAL WALL TREATMENTAWT
ARCHITECTURAL WOODWORKAW
AVERAGEAVG
AUXILIARYAUX
ASSEMBLYASSY
AS REQUIREDAR
APPROXIMATEAPPROX
APPROVEDAPPD
AMOUNTAMT
ALUMINUMALUM
ALTERNATEALT
ALIGNMENTALNMT
ALLOWANCEALLOW
AIR HANDLING UNITAHU
ABOVE FINISHED FLOORAFF
ADMINISTRATIONADMIN
ADJACENT, ADJOINING, ADJUSTABLEADJ
ADDITIONALADDL
ACOUSTICAL CEILING TILEACT
ACCESS PANELACS PNL
ACOUSTICAL INSULATIONACOUS INSUL
UNIT AIR CONDITIONING UNITA/C
ABBREVIATION TERM
EXTRUDED POLYSTYRENE BOARDXPS
TRANSFERXFER
X
WATERWTR
WEIGHTWT
WEATHERSTRIPWS
WHERE OCCURSWO
WALL HUNGWH
WINDOWWDW
WOOD DOOR, WOODWD
WALL CLEANOUTWCO
WATER CLOSETWC
WITHOUTW/O
WITHW/
WIDE, WESTW
W
VENT THROUGH ROOFVTR
VERIFYVRFY
VAPOR RETARDERVR
VOLUMEVOL
VOLATILE ORGANIC COMPOUNDVOC
VERIFY IN FIELDVIF
VERTICALVERT
VINYL COMPOSITION TILEVCT
VINYL BASEVB
VARIESVAR
V
UNLESS OTHERWISE NOTEDUON
UNLESS NOTED OTHERWISEUNO
UNDERWRITERS LABORATORIESUL
UNDERCUT DOORUCD
U
TYPICALTYP
TUBE STEELTS
TOP OF TO
THROUGHTHRU
THRESHOLDTHRES
THICKNESSTHK
TOP OF FINISH FLOORTFF
TO FLOOR BELOWTFB
TO FLOOR ABOVETFA
TRENCH DRAINTD
TREADT
T
CLNG SUSPENDED CEILINGSUSP
STRUCTURALSTRUCT
STANDARDSTD
SOUND TRANSMISSION CLASSSTC
STANDING SEAM (ROOF)SS
SPOT ELEVATIONSP EL
SOUND INSULATIONSND INS
SHEET METALSM
SIMILARSIM
SQUARE FOOT (FEET)SF
SOLID CORE WOOD DOORSCWD
SPLASH BLOCKSB
SOUTHS
682783_2215A-002.dgn
15 149
C F
IL
A N
O W
IC
Z
KICKPLATEKPL
KNOCKOUT PANELKOP
KNOCKOUTKO
KITCHENKIT
K
JANITORJAN
J
INSECT SCREENIS
INSULATED PANELIP
INTERIORINT
INSULATED METAL PANELINSUL PNL
INSULATIONINSUL
INSTALLINSTL
INSULATED METAL WALL PANELIMWP
INSIDE FACEIF
INSIDE DIMENSION, INSIDE DIAMETERID
INTERNATIONAL BUILDING CODEIBC
I
HEAVYHVY
HEIGHTHT
HORIZONTALHORIZ
HANDRAILHNDRL
HOLLOW METALHM
HEADERHDR
HEAVY DUTY, HARDBOARDHD
HOLLOW COREHC
HOSE BIBBHB
HAZARD, HAZARDOUSHAZ
HIGH, HATCH (ROOF)H
BD GYPSUM BOARDGYP
GYPSUM WALL BOARDGWB
GROUTGT
GRADE LINEGR LIN
GROUND FLOORGR FL
GLAZINGGLZ
GROUND LEVELGL
GRADE CLEANOUTGCO
GENERAL CONTRACTORGC
GYPSUM BOARDGB
GAGEGA
G
FUTUREFUT
FURNITURE, FURNISHFURN
FOOTINGFTG
FOOT, FEET, FIRE TREATEDFT
FULL SIZE, FAR SIDEFS
FRAME, FIRE RESISTENT, FIRE RATINGFR
FLAG POLE, FIRE PROOF, FIRE PROTECTIONFP
FACE OF WALLFOW
FACE OF STUD, FACE OF SLABFOS
FACE OF MASONRYFOM
FACE OF FINISHFOF
FACE OF CONCRETE, FACE OF CURBFOC
FACTORY MUTUALFM
FLOORFLR
FLOORINGFLG
FLOOR LINEFL
FIXTUREFIXT
FINISHFIN
FILLETFIL
FIGUREFIG
FROM FLOOR BELOWFFB
FROM FLOOR ABOVEFFA
FINISH FACEFF
FIRE EXTINGUISHER CABINETFEC
FIRE EXTINGUISHERFE
FOUNDATIONFDTN
FLOOR DRAINFD
FACTORYFCTY
FLOOR CLEAN OUTFCO
FABRICFAB
FEMALEF
F
EXTERIOR, EXTINGUISHEREXT
EXISTINGEXIST
EACH WAYEW
EXISTING ROOF DRAINERD
EQUIVALENTEQUIV
EQUIPMENTEQUIP
EQUALEQ
EXPANDED POLYSTYRENEEPS
ETHYLENE PROPYLENE DIENE MONOMER RUBBEREPDM
EDGE OF SLABEOS
ELEVATORELEV
ELEVATION, EACH LAYEREL
EXPANSION JOINTEJ
EXTERIOR INSULATION AND FINISH SYSTEMEIFS
ELECTRIC HAND DRYEREHD
EXTERIOR FINISH, EACH FACEEF
EACHEA
EASTE
E
REVEALRVL
RIGHTRT
REINFORCING STEELRST
ROUGH OPENINGRO
RAILINGRLG
RIGHT HAND, ROOF HATCHRH
ROOFINGRFG
REVISIONREV
REQUIREDREQD
REQUIREREQ
REPLACEREPL
REFERENCEREF
RIGID INSULATION, SOLIDRDG INS
ROOF DRAINRD
REFLECTED CEILING PLANRCP
RUBBER BASERB
RISER, RADIUSR
R
PURLINSPUR
PARTITIONPTN
PRESSURE TREATED, PAINTEDPT
PROPERTYPROP
PAIRPR
POSITIVEPOS
PANELPNL
PLYWOODPLYWD
PLATE GLASSPL GL
PROPERTY LINEPL
PERPENDICULARPERP
PERIMETERPERIM
PARALLELPAR
P
ORIENTED STRAND BOARDOSB
OVERFLOW ROOF DRAINORD
OUTSIDE RADIUSOR
OPTIONALOPT
OPPOSITEOPP
OPENINGOPNG
OUTSIDE FACE OF STUDSOFS
OWNER FURNISHED OWNER INSTALLEDOFOI
OUTSIDE FACEOF
OUTSIDE DIMENSION, OUTSIDE DIAMETEROD
ON CENTEROC
OVERALLOA
O
NEAR SIDE, NARROW STILENS
NOISE REDUCTION COEFFICIENTNRC
NOISE REDUCTIONNR
NUMBERNO
NOT IN CONTRACTNIC
NATIONAL FIRE PROTECTION ASSOCIATIONNFPA
NEAR FACENF
NARROWNAR
NOT APPLICABLENA
NORTHN
MULLIONMULL
METAL ROOFMTLR
METALMTL
MOUNTINGMTG
METAL THRESHOLDMT
MOP SINKMS
MODELMOD
MASONRY OPENINGMO
MILLWORKMLWK
MITERMIT
MISCELLANEOUSMISC
MINIMUM, MINUTEMIN
MIDDLEMID
MANUFACTURERMFR
MANUFACTUREDMFD
MILL FINISHMF
MEMBRANEMEMB
MEDIUMMED
METAL DECKMD
MAKE UP AIR UNITMAU
MATERIALMATL
M
LAYERLYR
LARGELRG
LOWPOINTLPT
LINE OF SIGHTLOS
LOCATIONLOC
LEFT HANDLH
LINEAR FOOTLF
LAVATORYLAV
ANGLEL
LICENSED
ARCHITECT
STATE O F IDAHO
AR-916427
s ig n e d b y
C h e ck e d b y
D ra w n b y
C a d F il e
D a te
P ro je ct
C H
M H
IL
L
S y m b o l
A p p ro v D a te
D e s c ri p ti o n
Drawing Number:
A B C D E F G H
GUNFIGHTERS
HOME OF THE
COMBAT COMMAND
AIR
DEPARTMENT OF
MOUNTAIN HOME AFB.
THE AIR FORCE
MOUNTAIN HOME
AFB
U.S. AIR FORCE
366 CES/CECD
1030 LIBERATOR ST.
MOUNTAIN HOME AFB, ID
83648-5442
E a s t F ro n t S tr e et
S u it e
5A -1
0.
d g n
S p e c
P ro je ct
B o is e I d a h o
2-
FILENAME: PLOT DATE: PLOT TIME:2019\04\24 1:58:48 PM
SHEET of
/2
/2
F A
C
IL
IT
Y
KEY PLAN
PLAN TRUE
N
A C
B D
Q Y Z
H
-8
R E P
A
IR
S
Q U
A D O
P S
C E
R T
IF
IE
D F
IN
A L D
E S
P P L
Y
VEST
OFFICE
VAULT
CRYPTO
OFFICE
EXEC
OSS CC
UFC
SEC ADMINADMIN
BRF
WCCS AREA
VAULT
SECURE
VEST
OPER
COMP
MUNS
AFE
CHEM
HAZ
BENC
AFE
MAIN SHOP
AFE
MAIN SHOP
AFE
C O
R R
ID
O R
CORRIDORCORRIDOR
C O
R R
ID
O R
C O
R R
ID
O R
C O
R R
ID
O R
C O
R R
ID
O R
WALKWAY
STORAGE
AFE
AUDITORIUM
C O
R R
ID
O R
C O
R R
ID
O R
ROOM
MECHANICAL
ROOM
MECHANICAL
ROOM
ELECTRICAL
ROOM
MECHANICAL
STORAGE
SERE
FLT CHF
AFE
SUPT
AFE
SAD
COMMON AREA
INTEL
PLANNING
INTEL
OSK
ROOM
MOM
MEN
WOMEN
JAN
VEST
ROOM
CONFERENCE
GLO
OFC
GLO
SGT
1STUMP
PLN
MSN
STOR
ADMIN
DO
COMM
SUPT
SQ
TRNG
SERE
TRNG
SERE
C O
R R
ID
O R
C O
R R
ID
O R
PHYSIO
AERO
HARMSERE
ROOM
CONFERENCE
MAIN
MAN
AERO
STOR
UDM
CONTROL
UDM
UDM
ROOM
CONFERENCE OPS
RANGE
WOMEN
JAN
OFFICE
C O
R R
ID
O R
VEST
CORRIDOR
103102
113 114 115
106 107
119 120
122 124
126125
2 174 175
176 178
185 186
188 189
170 171
C O
R R
ID
O R
FLT/CC
OSO
MGR
P5
CHAPLAIN
OSOTSCHED
AIR SPACE
SUPT
HARM
VEST
ROOM
HERITAGE
CVN 1
CVN 2 CVN 3
CVN 4
CVN 5
CVN 7
CVN 6
C V
N
ROOM 1
ROOM 2
CVN 10
C H
A S
E
ROOM 3
CVN 9
MEN
PARA ROOM
AFE
TRAINING
AFE
A
B
2 3 4
C
A-110
KEYED NOTES
GENERAL NOTES
1/16"=1'-0"
OVERALL FLOOR PLAN
O V E
R A
L L F
L O
O R P
L A
N
J R
E S
E
IG
H
D D
A L S
O G
L
IO
A R
C H
IT
E C
T U
R A
L
LEGEND:
EXISTING ITEMS TO REMAIN
NEW OR MODIFIED ITEMS
682783_2215A-110.dgn
L
IN
E
M A
T C
H
A -1
A -1
LINE
MATCH
A-111
A-112
L
IN
E
M A
T C
H
A -1
A -1
LINE
MATCH
A-113
A-114
DETAILED INFORMATION
OF NEW WORK, SEE A-111, A-112, A-113, AND A-114 FOR
THIS PLAN IS INTENDED TO GIVE AND OVERALL LAYOUT B.
FOR ADDITIONAL INFORMATION
REFER TO ELECTRICAL AND MECHANICAL DEMOLITION A.
6'-8"
26'-6" 28'-8"
48" MIN.
EQUAL
48" MIN.
EQUAL
24 149
C F
IL
A N
O W
IC
Z
30'-0"
INDICATED, SEE 10/A-503 FOR TYPICAL LAYOUT
SECURE TO THE FLOOR IN THE CONFIGURATION
NEW SEATING TO MATCH EXISTING DESIGN AND COLOR, 2.
FOR TYPICAL LAYOUT
FLOOR IN THE CONFIGURATION INDICATED, SEE 10/A-503
EXISTING SEATING, RELOCATE AND SECURE TO THE 1.
LICENSED
A RCHITECT
STA TE OF IDAHO
A R-916427 s ig n e d b y
C h e ck e d b y
D ra w n b y
C a d F il e
D a te
P ro je ct
C H
M H
IL
L
S y m b o l
A p p ro v D a te
D e s c ri p ti o n
Drawing Number:
A B C D E F G H
GUNFIGHTERS
HOME OF THE
COMBAT COMMAND
AIR
DEPARTMENT OF
MOUNTAIN HOME AFB.
THE AIR FORCE
MOUNTAIN HOME
AFB
U.S. AIR FORCE
366 CES/CECD
1030 LIBERATOR ST.
MOUNTAIN HOME AFB, ID
83648-5442
E a s t F ro n t S tr e et
S u it e
5A -1
1.
d g n
S p e c
P ro je ct
B o is e I d a h o
2-
FILENAME: PLOT DATE: PLOT TIME:2019\04\24 2:01:08 PM
SHEET of
/2
/2
F A
C
IL
IT
Y
PLAN TRUE
N
A C
B D
Q Y Z
H
-8
R E P
A
IR
S
Q U
A D O
P S
C E
R T
IF
IE
D F
IN
A L D
E S
P P L
Y
OPER
COMP
MUNS
AFE
CHEM
HAZ
BENC
AFE
MAIN SHOP
AFE
MAIN SHOP
AFE
WALKWAY
STORAGE
AFE
AUDITORIUM
ROOM
MECHANICAL
ROOM
ELECTRICAL
VEST
PARA ROOM
AFE
TRAINING
AFE
A-111
E
A A
KEYED NOTES
GENERAL NOTES
X
FLOOR PLAN - AREA A
1/8"=1'-0"
KEY PLAN
J R
E S
E
IG
H
F L
O O
R P
L A
N
A R
C H
IT
E C
T U
R A
L
LEGEND:
EXISTING ITEMS TO REMAIN
NEW OR MODIFIED ITEMS
682783_2215A-111.dgn
L
IN
E
M A
T C
H
A -1
LINE
MATCH
A-112
7A
2B
155A
B
162A
148A
153A
8A
1A
B
A
4A
152A
2B
151A
4'-0"
E Q
E Q
30'-0"
SEE A-113
J J
J
A-503
5 5
12 1212
TYP
W-19 W-20 W-21
A-503
8'-8" 10'-0" 6'-8"
25 149
C F
IL
A N
O W
IC
Z
SEALANT
ALL OTHER PENETRATIONS TO BE SEALED W/ 1-HR
MECHANICAL SYSTEMS ARE TO BE GROUTED SOLID.
NOT HAVE CONDUITS, ELECTRICAL SYSTEMS, OR
ALL PENETRATIONS IN EXISTING CMU WALLS THAT DO 14.
COORDINATE WITH MECHANICAL
GROUT TO MATCH THE EXISTING CMU COLOR.
HOLES IN EXISTING CMU WITH INTEGRAL COLORED
13.
NEW DOWNSPOUT, SEE A-150, 3/A-50312.
FINISH FACE OF EXISTING WALL
FINISH FACE OF NEW WALL TO ALIGN FLUSH WITH 11.
WITHIN THE ROOM
AND PREVENT THE TRAVEL OF MOISTURE FROM
TO BE SEALED WITH SEALANT SO AS TO AIR TIGHT
MECHANICAL, ELECTRICAL, AND BOTTOM OF WALL)
ALL WALL/FLOOR/CEILING PENETRATIONS (INCLUDING 10.
FINAL FINISH
WHERE WALL ITEMS WERE REMOVED, PREPARE FOR
PATCH WALL WHERE WALL WAS DEMOLISHED OR 9.
TRANSLUCENT WINDOW SYSTEM8.
EXISTING FIRE EXTINGUISHER CABINET7.
NOT USED6.
2" x 2" x 48" SATIN STAINLESS STEEL CORNER GUARD5.
THRESHOLD4.
REQUIRED FOR NEW WORK
REINSTALL RAISED FLOOR SYSTEM, MODIFY AS 3.
ALONG WALL INDICATED IN ROOM 147. SEE 9/A-503
RAISED FLOOR TIGHT TO WALL AND CENTERED 2.
OFFICER, SEE 6/A-503
COORDINATE EXACT LOCATION WITH CONTRACTING
2'-2" x 2'-0" ACCESS FLOOR INSPECTION COVER, 1.
G B
U R
L E
Y
GUARDS.
ALL OUTSIDE CORNERS TO RECIEVE CORNER F.
ICD 705)
PAINTED FROM TRUE FLOOR TO TRUE CEILING (IAW
PERIMETER WALL ASSEMBLY SHALL BE FINISHED AND
WITHIN SECURED BOUNDARY AREAS, THE ENTIRE E.
FOR WALL TYPES, SEE SHEET A-001.D.
DAMAGE REPAIRED FOR FINAL WALL FINISH.
ALL EXISTING WALLS TO HAVE ALL HOLES AND WALL C.
INTERIOR AND WINDOW SCHEDULES.
SEE SHEETS A-601, A-610 AND A-611 FOR DOOR, B.
NOTE 1/A-001.
EXISTING FINISHES UNLESS NOTED OTHERWISE, SEE
DIMENSIONS ARE FACE OF STUD OR FACE OF A.
LICENSED
A RCHITECT
STA TE OF IDAHO
A R-916427
P P L
Y
VEST
OFFICE
OPER
COMP
CORRIDOR
C O
R R
ID
O R
C O
R R
ID
O R
C O
R R
ID
O R
AUDITORIUM
TRNG
SERE
C O
R R
ID
O R
PHYSIO
AERO
ROOM
CONFERENCE
MAIN
MAN
AERO
STOR
UDM
CONTROL
UDM
UDM
ROOM
CONFERENCE OPS
RANGE
WOMEN
JAN
OFFICE
C O
R R
ID
O R
2 174 175
176 178
188 189
FLT/CC
OSO
MGR
P5
CHAPLAIN
OSOTSCHED
AIR SPACE
ROOM
HERITAGE
CVN 1
CVN 2 CVN 3
MEN
B
C
D
D e s ig n e d b y
C h e ck e d b y
D ra w n b y
C a d F il e
D a te
P ro je ct
C H
M H
IL
L
S y m b o l
A p p ro v D a te
D e s c ri p ti o n
Drawing Number:
A B C D E F G H
GUNFIGHTERS
HOME OF THE
COMBAT COMMAND
AIR
DEPARTMENT OF
MOUNTAIN HOME AFB.
THE AIR FORCE
MOUNTAIN HOME
AFB
U.S. AIR FORCE
366 CES/CECD
1030 LIBERATOR ST.
MOUNTAIN HOME AFB, ID
83648-5442
E a s t F ro n t S tr e et
S u it e
5A -1
2.
d g n
S p e c
P ro je ct
B o is e I d a h o
2-
FILENAME: PLOT DATE: PLOT TIME:2019\04\24 2:03:22 PM
SHEET of
/2
/2
F A
C
IL
IT
Y
PLAN TRUE
N
A C
B D
Q Y Z
H
-8
R E P
A
IR
S
Q U
A D O
P S
C E
R T
IF
IE
D F
IN
A L D
E S
A-112
E
A B
KEYED NOTES
GENERAL NOTES
X
FLOOR PLAN - AREA B
1/8"=1'-0"
L
IN
E
M A
T C
H
J R
E S
E
IG
H
F L
O O
R P
L A
N
A R
C H
T E
C T
U R
A L
LEGEND:
A -1
A-111
LINE
MATCH
G B
U R
L E
Y
682783_2215A-112.dgn
2C
163A 102B
168A
167A
5A
6A
2A
173A 174A
4B
9B
0A
172B 179A
179C
181B
181A
175A
2A
7A
176A 177B
183B 183A
178A
2C
4A
9A
169B
170A
7C
149A
150A
3B
8A
187A
9A
4'-0"10'-0"4'-0"8'-4"4'-0"8'-4"4'-0"8'-8"4'-0"10'-8"4'-0"12'-0"4'-0"19'-4"4'-0"
2'-8"
4'-0"16'-0"
W-1 W-2
B
C
B
B
3C
A
MAIN SHOP
AFE
5'-0"
"A
A
B
J
JJ
J J
J J
A-403
F
W-3 W-4 W-5 W-6 W-7 W-8 W-9
174C
EXISTING ITEMS TO REMAIN
NEW OR MODIFIED ITEMS
H
A
A
C C A
H A A
A
A
A
K
A
ACK
PARA ROOM
AFE
A
TYP TYP
TYP
TYP
TYP
TYP
A-402
SIM.
TYP
FIN.
F
IN
A-503
A-401
B
26 149
C F
IL
A N
O W
IC
Z
1'-6"
7'-4"
NEW DOWNSPOUT, SEE A-150 AND DETAIL 3/A-50314.
DURING CONSTRUCTION
EXISTING FOLDING PARTITION TO REMAIN, PROTECT 13.
FINISH
WALL ITEMS WERE REMOVED, PREPARE FOR FINAL
PATCH WALL WHERE WALL WAS DEMOLISHED OR WHERE 12.
FACE OF EXISTING WALL
FINISH FACE OF NEW WALL TO ALIGN FLUSH WITH FINISH 11.
THRESHOLD10.
2" x 2" x 48" SATIN STAINLESS STEEL CORNER GUARD9.
REQUIRED FOR NEW WORK
REINSTALL RAISED FLOOR SYSTEM, MODIFY AS 8.
ROOM
PREVENT THE TRAVEL OF MOISTURE FROM WITHIN THE
BE SEALED WITH SEALANT SO AS TO AIR TIGHT AND
MECHANICAL, ELECTRICAL, AND BOTTOM OF WALL) TO
ALL WALL/FLOOR/CEILING PENETRATIONS (INCLUDING 7.
CONSTRUCTION
NEW WALL FRAMING TO MATCH ADJACENT WALL 6.
SKYLIGHT ABOVE, SEE 2/A-5035.
7/8" METAL FURRING WITH GYPSUM BOARD4.
SHEETS A-401 AND A-402
DRINKING FOUNTAIN, SEE PLUMBING DRAWINGS AND 3.
NEW WINDOW, TYP2.
OFFICER, SEE 6/A-503
COORDINATE EXACT LOCATION WITH CONTRACTING
2'-2" x 2'-0" ACCESS FLOOR INSPECTION COVER, 1.SIM
GUARDS.
ALL OUTSIDE CORNERS TO RECEIVE CORNER G.
ICD 705).
PAINTED FROM TRUE FLOOR TO TRUE CEILING (IAW
PERIMETER WALL ASSEMBLY SHALL BE FINISHED AND
WITHIN SECURED BOUNDARY AREAS, THE ENTIRE F.
FOR WALL TYPES, SEE SHEET A-001E.
WINDOWS AS REQUIRED
REPAIR AND PATCH WALL ADJACENT TO NEW D.
DAMAGE REPAIRED FOR FINAL WALL FINISH.
ALL EXISTING WALLS TO HAVE ALL HOLES AND WALL C.
INTERIOR AND WINDOW SCHEDULES.
SEE SHEETS A-601, A-610 AND A-611 FOR DOOR, B.
NOTE 1/A-001.
EXISTING FINISHES UNLESS NOTED OTHERWISE, SEE
DIMENSIONS ARE FACE OF STUD OR FACE OF A.
SIM
LICENSED
A RCHITECT
STATE OF IDAHO
A R-916427
WCCS AREA
VAULT
SECURE
C O
R R
ID
O R
C O
R R
ID
O R
ROOM
MECHANICAL
ROOM
MECHANICAL
STORAGE
SERE
FLT CHF
AFE
SUPT
AFE
SAD
COMMON AREA
INTEL
PLANNING
INTEL
ROOM 1
ROOM 2
C H
A S
E
ROOM 3
D e s ig n e d b y
C h e ck e d b y
D ra w n b y
C a d F il e
D a te
P ro je ct
C H
M H
IL
L
S y m b o l
A p p ro v D a te
D e s c ri p ti o n
Drawing Number:
A B C D E F G H
GUNFIGHTERS
HOME OF THE
COMBAT COMMAND
AIR
DEPARTMENT OF
MOUNTAIN HOME AFB.
THE AIR FORCE
MOUNTAIN HOME
AFB
U.S. AIR FORCE
366 CES/CECD
1030 LIBERATOR ST.
MOUNTAIN HOME AFB, ID
83648-5442
E a s t F ro n t S tr e et
S u it e
5A -1
3.
d g n
S p e c
P ro je ct
B o is e I d a h o
2-
FILENAME: PLOT DATE: PLOT TIME:2019\04\24 2:06:54 PM
SHEET of
/2
/2
F A
C
IL
IT
Y
PLAN TRUE
N
A C
B D
Q Y Z
H
-8
R E P
A
IR
S
Q U
A D O
P S
C E
R T
IF
IE
D F
IN
A L D
E S
A-113
E
A C
KEYED NOTES
GENERAL NOTES
X
FLOOR PLAN - AREA C
1/8"=1'-0"
A
J R
E S
E
IG
H
F L
O O
R P
L A
N
A R
C H
IT
E C
T U
R A
L
LEGEND:
G B
U R
L E
Y
682783_2215A-113.dgn
L
IN
E
M A
T C
H
A -1
LINE
MATCH
A-114
148B
7B
5A
5C
6A
3A
2A
1A
1C
141B
142C
142B
4C
5A
6A
0A
139A
138A
134A
9B
4B
155D
MECH RM
AUDITORIUM
30'-0"
SEE A-111
TYP
TYP
TYP
A
A
A
A
A
A
E
OSK
144A
132A
3A
133B
C O
R R
ID
O R
C O
R R
ID
O R
6"
10'-8"
5'-6"
5'-6"
A
A
J
J
J
A-403
A-503
A-503
CONC. FLR.
ACCESS FLR.
131B
EXISTING ITEMS TO REMAIN
NEW OR MODIFIED ITEMS
F
IN
IS
H E
D
FIN.
F
IN
IS
H E
D
FIN.
FINISHED
W-22
1313 1313
8 11 11
UP
TYP
TYP
6'-0"
4'-0"
27 149
C F
IL
A N
O W
IC
Z
4'-9"
2" x 2" x 48" SATIN STAINLESS STEEL CORNER GUARD15.
NEW ROOF DRAIN OUTLET, SEE PLUMBING DRAWINGS
SPLASH BLOCK AT EXISTING ROOF DRAIN OUTLET AND 14.
NEW DOWNSPOUT, SEE A-150 AND DETAIL 3/A-50313.
EXISTING DOOR THAT WAS REMOVED
NEW DOOR TO BE PAINTED GREEN TO MATCH 12.
NEW FINISH
EXISTING OVERHEAD DOOR TO REMAIN, PREPARE FOR 11.
FINAL FINISH
WHERE WALL ITEMS WERE REMOVED, PREPARE FOR
PATCH WALL WHERE WALL WAS DEMOLISHED OR 10.
REMOVEABLE RAMP, SLOPE 1:129.
TRANSLUCENT WALL PANEL8.
EACH SIDE
ALIGN FINAL FACE OF NEW FINISH WITH EXISTING
MATCHING THE ADJACENT WALL CONSTRUCTION.
INFILL OPENING WITH WALL CONSTRUCTION TO 7.
REQUIRED FOR NEW WORK
REINSTALL RAISED FLOOR SYSTEM, MODIFY AS 6.
EXISTING WALL MURAL TO BE PROTECTED5.
NEW GYPSUM WALL BOARD ON EXISTING STUDS4.
SHEET A-401
DRINKING FOUNTAIN, SEE PLUMBING DRAWINGS AND 3.
RAISED FLOOR CENTERED IN ROOM2.
OFFICER, SEE 6/A-503
COORDINATE EXACT LOCATION WITH CONTRACTING
2'-2" x 2'-0" ACCESS FLOOR INSPECTION COVER, 1.
J
GUARDS.
ALL OUTSIDE CORNERS TO RECEIVE CORNER G.
ICD 705).
PAINTED FROM TRUE FLOOR TO TRUE CEILING (IAW
PERIMETER WALL ASSEMBLY SHALL BE FINISHED AND
WITHIN SECURED BOUNDARY AREAS, THE ENTIRE F.
FOR WALL TYPES, SEE SHEET A-001E.
WINDOWS AS REQUIRED.
REPAIR AND PATCH WALL ADJACENT TO NEW D.
DAMAGE REPAIRED FOR FINAL WALL FINISH.
ALL EXISTING WALLS TO HAVE ALL HOLES AND WALL C.
INTERIOR AND WINDOW SCHEDULES.
SEE SHEETS A-601, A-610 AND A-611 FOR DOOR, B.
NOTE 1/A-001.
EXISTING FINISHES UNLESS NOTED OTHERWISE, SEE
DIMENSIONS ARE FACE OF STUD OR FACE OF A.
LICENSED
A RCHITECT
STATE OF IDAHO
A R-916427
VAULT
CRYPTO
OFFICE
EXEC
OSS CC
UFC
SEC ADMINADMIN
BRF
VEST
C O
R R
ID
O R
CORRIDOR
C O
R R
ID
O R
OSK
ROOM
MOM
MEN
WOMEN
JAN
ROOM
CONFERENCE
GLO
OFC
GLO
SGT
1STUMP
PLN
MSN
STOR
ADMIN
DO
COMM
SUPT
SQ
TRNG
SERE
TRNG
SERE
C O
R R
ID
O R
HARMSERE
ROOM
CONFERENCE
MAIN
VEST
CORRIDOR
113 114 115
106 107
119 120
122 124
126125
185 186
170 171
C O
R R
ID
O R
SUPT
HARM
VEST
CVN 1
CVN 3
CVN 4
CVN 5
CVN 7
CVN 6
C V
N
CVN 10
CVN 9
3 4
D e s ig n e d b y
C h e ck e d b y
D ra w n b y
C a d F il e
D a te
P ro je ct
C H
M H
IL
L
S y m b o l
A p p ro v D a te
D e s c ri p ti o n
Drawing Number:
A B C D E F G H
GUNFIGHTERS
HOME OF THE
COMBAT COMMAND
AIR
DEPARTMENT OF
MOUNTAIN HOME AFB.
THE AIR FORCE
MOUNTAIN HOME
AFB
U.S. AIR FORCE
366 CES/CECD
1030 LIBERATOR ST.
MOUNTAIN HOME AFB, ID
83648-5442
E a s t F ro n t S tr e et
S u it e
5A -1
4.
d g n
S p e c
P ro je ct
B o is e I d a h o
2-
FILENAME: PLOT DATE: PLOT TIME:2019\04\24 2:08:37 PM
SHEET of
/2
/2
F A
C
IL
IT
Y
PLAN TRUE
N
A C
B D
Q Y Z
H
-8
R E P
A
IR
S
Q U
A D O
P S
C E
R T
IF
IE
D F
IN
A L D
E S
A-114
E
A D
KEYED NOTES
GENERAL NOTES
X
FLOOR PLAN - AREA D
1/8"=1'-0"
J R
E S
E
IG
H
F L
O O
R P
L A
N
A R
C H
IT
E C
T U
R A
L
LEGEND:
G B
U R
L E
Y
682783_2215A-114.dgn
B
C
D
LINE
MATCH
A-113
L
IN
E
M A
T C
H
A -1
171A 117A 1A
127A
128A
128B
130A
9A
4B
5A
186A
2A
5A
6A
8A
112A
3A
4A
5A
115B
110A
113B
103A
8A
6A
4A
3A
2A
1A
0A
9A
111A
104A103B
192A 192B
191A
0A
1A
3A
4A
170B
AUDITORIUM
TYP
TYP
W-11
7A
126A B
0A
9A
7A
ROOM
CONFERENCE
MAIN
1'-9"
F
J
J
J
J J
J
J
W-12 W-13 W-14 W-15 W-16
4'-0"9'-4"4'-0"
2'-8"
4'-0"8'-0"4'-0"
2'-8"
4'-0"10'-8"4'-0"4'-0"4'-0"8'-0"
187B
J J
EXISTING ITEMS TO REMAIN
NEW OR MODIFIED ITEMS
A
C C
A
H
A
B
TYP12
12 1112
W-10
W -1
W-17
9 9
6'-0"
A-401
B
28 149
C F
IL
A N
O W
IC
Z
12 12
GUARDS.
ALL OUTSIDE CORNERS TO RECEIVE CORNER G.
ICD 705).
PAINTED FROM TRUE FLOOR TO TRUE CEILING (IAW
PERIMETER WALL ASSEMBLY SHALL BE FINISHED AND
WITHIN SECURED BOUNDARY AREAS, THE ENTIRE F.
FOR WALL TYPES, SEE SHEET A-001E.
WINDOWS AS REQUIRED.
REPAIR AND PATCH WALL ADJACENT TO NEW D.
DAMAGE REPAIRED FOR FINAL WALL FINISH.
ALL EXISTING WALLS TO HAVE ALL HOLES AND WALL C.
INTERIOR AND WINDOW SCHEDULES.
SEE SHEETS A-601, A-610 AND A-611 FOR DOOR, B.
NOTE 1/A-001.
EXISTING FINISHES UNLESS NOTED OTHERWISE, SEE
DIMENSIONS ARE FACE OF STUD OR FACE OF A.
2" x 2" x 48" SATIN STAINLESS STEEL CORNER GUARD12.
FINISH
WALL ITEMS WERE REMOVED, PREPARE FOR FINAL
PATCH WALL WHERE WALL WAS DEMOLISHED OR WHERE 11.
THRESHOLD10.
NEW DOWNSPOUT, SEE A-150 AND DETAIL 3/A-5039.
EXISTING VAULT DOOR TO REMAIN AND BE PROTECTED.8.
LOCATION
RELOCATE EXISTING CELL PHONE LOCKERS TO THIS 7.
REQUIRED FOR NEW WORK
REINSTALL RAISED FLOOR SYSTEM, MODIFY AS 6.
NEW GYPSUM WALL BOARD ON EXISTING STUDS5.
LOCKERS, SEE DETAIL 11/A-4034.
AND A-402 DRAWINGS
DRINKING FOUNTAIN, SEE PLUMBING AND SHEETS A-401 3.
NEW WINDOW, TYP2.
OFFICER, SEE 6/A-503
COORDINATE EXACT LOCATION WITH CONTRACTING
2'-2" x 2'-0" ACCESS FLOOR INSPECTION COVER, 1.
LICENSED
A RCHITECT
STA TE OF IDAHO
A R-916427 s ig n e d b y
C h e ck e d b y
D ra w n b y
C a d F il e
D a te
P ro je ct
C H
M H
IL
L
S y m b o l
A p p ro v D a te
D e s c ri p ti o n
Drawing Number:
A B C D E F G H
GUNFIGHTERS
HOME OF THE
COMBAT COMMAND
AIR
DEPARTMENT OF
MOUNTAIN HOME AFB.
THE AIR FORCE
MOUNTAIN HOME
AFB
U.S. AIR FORCE
366 CES/CECD
1030 LIBERATOR ST.
MOUNTAIN HOME AFB, ID
83648-5442
E a s t F ro n t S tr e et
S u it e
5A -1
0.
d g n
S p e c
P ro je ct
B o is e I d a h o
2-
FILENAME: PLOT DATE: PLOT TIME:2019\04\24 2:10:37 PM
SHEET of
/2
/2
F A
C
IL
IT
Y
Z
H
-8
R E P
A
IR
S
Q U
A D O
P S
C E
R T
IF
IE
D F
IN
A L D
E S
2 4
A
C
A-150
E S
E
IG
H
A R
C H
IT
E C
T U
R A
L
LEGEND:
682783_2215A-150.dgn
G B
U R
L E
Y
R O
O F P
L A
N
ROOF PLAN
EXISTING ITEMS TO REMAIN
NEW OR MODIFIED ITEMS
RIDGE
4 4
TYP
4 4 4
4 5
TYP
TYP
TYP
TYP
8'-0"16'-4"55'-3"13'-8"11'-2"21'-2"18'-0"27'-2"33'-6"
TYP
25'-8"8'-0"13'-6"12'-0"21'-7"12'-0"69'-1"49'-4"
RIDGE
/2
20'-5" 16'-4" 14'-6" 18'-6" 16'-0" 12'-4"
26'-6" 67'-0" 5'-7"
N
PLAN TRUE
N
S L
O P
E S
L O
P E
S L
O P
E
S L
O P
E
S L
O P
E
A-201
A-201
TYP
TYP
TYP
TYP
A-2011
TYP
TYP
TYP
TYP
TYP
A-510
A-510
A-510
A-510
A-510
A-510
A-510
A-511
A-510
A-510
A-510
17 1
A-510
S L
O P
E
A-510
A-511
A-511
COPING
SIM AT
A-511
TYP OF 3
29 149
C F
IL
A N
O W
IC
Z
S L
O P
E
TYP
TYP
TYP
WITH MECHANICAL.
PREFABRICATED EQUIPMENT CURBS, COORDINATE C.
OPENINGS ETC. WITH MECHANICAL AND PLUMBING
COORDINATE ROOF PENETRATIONS, CURBED B.
WITHIN EXISTING SCUPPER OPENINGS.
EXISTING. NEW SCUPPERS ARE TO BE INSTALLED
SCUPPERS AND ROOF DRAIN HEIGHT MATCHES
PARAPET WALL AT ROOF DRAINS SO THAT EXISTING
MATCH HEIGHT OF EXISTING ROOF INSULATION AT
NEW POLYISO ROOF INSULATION (RIGID/TAPERED) TO A.
DECK
RIGID INSULATION OVER EXISTING METAL ROOF
OVER HIGH DENSITY COVER BOARD OVER R-30 MIN.
NEW FULLY ADHEARED EPDM ROOFING SYSTEM 21.
INDICATED
WALK MAT ADHEARED TO EPDM ROOFING SYSTEM AS 20.
RIGID INSULATION BUILD UP AREA19.
ROOF PENETRATION, SEE 11/A-51118.
ROOF/OVERFLOW DRAIN. SEE 3/A-51117.
TAPERED INSULATION CRICKET16.
PROTECT DURING CONSTRUCTION
EXISTING CANOPY ROOF BELOW TO REMAIN, 15.
BLOCK AT ROOF DRAIN PIPE AT GRADE
COLLECTOR HEAD, SEE 3/A-503. CONCRETE SPLASH 14.
ROOF TO WALL EDGE FLASHING, SEE 7/A-51113.
OVER EPDM UNDER COPING CAP
20 GA. (4" x 4") BREAK SHAPE CORNER FLASHING 12.
EXPANSION JOINT WALL TO STEP UP 8", SEE 8/A-51011.
INDICATES CHANGE IN ROOF SLOPE10.
SKYLIGHT/SOLAR TUBE, SEE 9/A-5119.
NEW EXPANSION JOINT, SEE 4/A-5108.
NEW SKYLIGHT, SEE 2/A-5037.
NEW COPING AND FLASHING, SEE 1/A-510 AND 2/A-5106.
DECK
TAPERED INSULATION OVER EXISTING METAL ROOF
OVER HIGH DENSITY COVER BOARD OVER R-30 MIN.
NEW FULLY ADHEARED EPDM ROOFING SYSTEM 5.
COLLECTOR HEAD, SEE 10/A-510
NEW ROOF DRAIN, OVERFLOW SCUPPER AND 4.
PLUMBING AND HVAC VENTS, SEE 11/A-5113.
12/A-511
ROOF TOP HOOD AND CURBING, SEE 8/A-511 AND 2.
CMU PARAPET EXTENSION1.
4'-4 1/2 "
33'-10"
LICENSED
A RCHITECT
STATE OF IDAHO
A R-916427 s ig n e d b y
C h e ck e d b y
D ra w n b y
C a d F il e
D a te
P ro je ct
C H
M H
IL
L
S y m b o l
A p p ro v D a te
D e s c ri p ti o n
Drawing Number:
A B C D E F G H
GUNFIGHTERS
HOME OF THE
COMBAT COMMAND
AIR
DEPARTMENT OF
MOUNTAIN HOME AFB.
THE AIR FORCE
MOUNTAIN HOME
AFB
U.S. AIR FORCE
366 CES/CECD
1030 LIBERATOR ST.
MOUNTAIN HOME AFB, ID
83648-5442
E a s t F ro n t S tr e et
S u it e
5A -2
1.
d g n
S p e c
P ro je ct
B o is e I d a h o
2-
FILENAME: PLOT DATE: PLOT TIME:2019\04\24 2:13:07 PM
SHEET of
/2
/2
F A
C
IL
IT
Y
Z
H
-8
R E P
A
IR
S
Q U
A D O
P S
C E
R T
IF
IE
D F
IN
A L D
E S
A-201
E S
E
IG
H
A R
C H
IT
E C
T U
R A
L
LEGEND:
682783_2215A-201.dgn
EXISTING ITEMS TO REMAIN
NEW OR MODIFIED ITEMS
A N
D R
O O
F S
E C
T
IO
N S
D D
A L S
O G
L
IO
P A
R T
IA
L W
A L L
E
L E
V A
T
IO
N
PARTIAL ELEVATION AT ROOF PARAPET
1/4"=1'-0"
14'-0"
1/8"=1'-0"
ROOF SECTION
A-150
A-150
A-510
A-510
A-510
A-510
A-510
INTERIOR SPACE INTERIOR SPACE
INTERIOR SPACE
1/8"=1'-0"
ROOF SECTION
A-150
INTERIOR SPACE
INTERIOR SPACE
A-510 A-510
A-510
OPP.
A-510
NEW CMU PARAPET EXTENSION
EXISTING CMU WALL
NEW COPING
ROOF SLOPE
A-510
A-510
A-510
"SLOPE
SLOPE
SLOPE
SLOPE
CMU WALL
EXISTING INTERIOR
CMU WALL
EXISTING INTERIOR
STRUCTURE
DECK AND ROOF
EXISTING METAL
STRUCTURE
DECK AND ROOF
EXISTING METAL
CHANGE
ROOF SLOPE
CMU WALL
EXISTING INTERIOR
STRUCTURE
DECK AND ROOF
EXISTING METAL
NEW ROOF SYSTEM
NEW ROOF SYSTEM
35 149
C F
IL
A N
O W
IC
Z
TYP
CMU WALL,
EXISTING
RIGID INSULATION BUILD-UP AREA, SEE SHEET A-150
1/2"±:12 3/8"±:12
1/2"±:12 1/2"±:12
3/8"±:12
SLOPE
5/8"±:12
LICENSED
A RCHITECT
STA TE OF IDAHO
A R-916427 s ig n e d b y
C h e ck e d b y
D ra w n b y
C a d F il e
D a te
P ro je ct
C H
M H
IL
L
S y m b o l
A p p ro v D a te
D e s c ri p ti o n
Drawing Number:
A B C D E F G H
GUNFIGHTERS
HOME OF THE
COMBAT COMMAND
AIR
DEPARTMENT OF
MOUNTAIN HOME AFB.
THE AIR FORCE
MOUNTAIN HOME
AFB
U.S. AIR FORCE
366 CES/CECD
1030 LIBERATOR ST.
MOUNTAIN HOME AFB, ID
83648-5442
E a s t F ro n t S tr e et
S u it e
5A -4
1.
d g n
S p e c
P ro je ct
B o is e I d a h o
2-
FILENAME: PLOT DATE: PLOT TIME:2019\04\24 2:15:40 PM
SHEET of
/2
/2
F A
C
IL
IT
Y
Z
H
-8
R E P
A
IR
S
Q U
A D O
P S
C E
R T
IF
IE
D F
IN
A L D
E S
WOMEN
MEN
OFFICE
JAN.
WOMEN
MEN
JAN.
M A
X
M A
X
M
IN 3
M A
X
M
IN
PIPES
EXPOSED
INSULATE
LAVATORIES & MIRRORS
DEPTH
17" MIN. LAV.
OR VANITY
TOP OF LAV
MIN
8"
LAV
LAV
WATER CLOSET
ACCESSIBLE
M A
X
TPD
12"
3'-0" MAX
SIDE
ON WIDE
44" A.F.F.
EXCEED
NOT TO
CONTROL
FLUSH
M
IN
MAX
54" MIN
42" MIN
GB-3
M
IN
M A
X
M
IN
MIN
36"
WC WC
MIN
2'-0"
MIN
12"
36"
GB-3
7"-9"
M A
X
THAN 44" A.F.F.
NO MORE
CONTROL
FLUSH
URINALS
URINAL
MIN.
14"
S P O
U T H
E
IG
H T
M
IN
M A
X
6" MAX 8" MIN
DF
M
IN
DRINKING FOUNTAIN
M
IN
S P O
U T H
E
IG
H T
M A
X
17"-18"
DF
DF
N O
N A
C C
E S
S
IB
L E
AUTOMATED PAPER TOWEL
PTD-1
SLOT
DISPENSING
SOAP DISPENSER
SD
N O
N A C
C E S
S
IB
L E
MB
ALARM OR
LIGHT SWITCH,
THERMOSTAT
SIGNAGEMOP HOOKS
ALARMS
DISPENSERS
MISC.
11"
SINK
FRONT OF
MAX FROM
MAX
6"
BOTTLE FILLER
DISPENSER
M
IN
M A
X
MG
MG
16"-18"
A-401
E S
E
IG
H
D D
A L S
O G
L
IO
A R
C H
IT
E C
T U
R A
L
682783_2215A-401.dgn
E N
L A
R G
E D P
L A
N S
A
ENLARGED RESTROOM AREA
1/4"=1'-0"
B
ENLARGED RESTROOM AREA
1/4"=1'-0"
5'-2" 6'-1" 5'-2"
5'-6"5'-2"5'-0"
5'-8"3'-0"3'-0"3'-0"3'-0"
2'-6" 2'-7" 2'-7" 2'-7" 2'-7"
11'-0"
2"
GENERAL NOTES
A-402
A-403
A-402
A-402
A-402
A-402
A-403
A-402
A-402
A-402
A-402
A-403
A-402
A-402
A-403
A-403
A-403
A-403
168A
167A
5A
6A
CODE FOR BUILDING CONSTRUCTION
INTERNATIONAL ACCESSIBILITY
PTD
TOILET ACCESSORY LEGEND
SOAP DISPENSER
DF
SD
DRINKING FOUNTAIN
P
S
TOILET PARTITION
URNAL SCREEN
WC WATER CLOSET
IP
NOTE: DIMENSIONS ARE CLEAR, MINIMUM FINISHED DIMENSIONS
INSULATE EXPOSED PIPES
NOTE: DIMENSIONS ARE CLEAR, MINIMUM FINISHED DIMENSIONS
PTD-1
CLWALL
KEYED NOTESX
P
TTDJ
TTDJ
TTDJ
TTDJ
WCTTDJ
TTDJ
WC
TTDJ WC
TTDJ WC
P L
A V
L A
V
LAV LAV LAV
SD
SD
PTD-1
SD
SD
S S S S
TTDJ
TTDJ
P
WC
WC
WC
WC
WC
WC
W C
W C
W C
W C
W C
TTDJ TTDJ
TTDJ
P
P
L A
V L
A V
L A
V L
A V
L A
V
SD
SD
SD
SD
L A
V L
A V
L A
V
DF
WC
WC
WC
L A
V
SD
L A
V
SD
L A
V
SD
PTD-1
W C
P
W C
W C
W C
TTDJ TTDJ TTDJ
URINAL
S
16'-2" 4'-5"17'-8"
A-112
A-114
3'-0"3'-0"3'-0"5'-9"
66 6
6 66
GRAB BAR, SIZE AS SHOWNGB-"X"
A-402
SD
6"
12'-6"
5'-6"6'-6"
1'-6"
TTDJ
TTDJ
MIN.
SD
SD
SD
PTD-1
6"
7'-10 1/2 "18'-4 1/2 "
4'-6"13'-2"
1'-6"
MIN.
TYP.
N
PLAN TRUE
N
N
PLAN TRUE
PAPER TOWEL DISPENSER
CORRIDOR
36 149
C F
IL
A N
O W
IC
Z
MH
MH
TYP
TYP
6.
5.
4.
3.
2.
1.
GB-3
GB-3
TTDJ
TTDJ
GB-3
GB-3
TYP
TYP
TTDJ
GB-3
P
GB-3
GB-3
TPD
GB-3
ABAABA
ABA
ABA URINAL NON ABA URINAL
MG MIRROR 24 X 36
MG
MG
MG
MG
MG
MG
MT
MG
MG
MG
MG
MG
MG
MG
MG
MT MIRROR, TILT 24 X 36
TTDJ TOILET TISSUE DISPENSER
MH MOP AND BROOM HOLDER (24")
URINALS
7 7
UNLESS NOTED OTHERWISE.
ALL DOORS ARE DIMENSIONED 4-INCHES FROM FACE OF STUD
INTERIOR HINGED - 5 LB.SLIDING - 5 LB.EXTERIOR - 8.5 LB.
DOOR OPENING FORCE:
GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS.
LOAD BETWEEN FASTENER AND SUPPORTING STRUCTURE.
OF 250 LBS. SHALL BE LESS THAN THE ALLOWABLE WITHDRAWAL
250 LB. PLUS MAXIMUM MOMENT FROM THE APPLICATION
TENSILE FORCE INDUCED BY DIRECT TENSION FORCE OF
LATERAL LOAD OF FASTENER OR SUPPORT STRUCTURE.
APPLICATION OF 250 LB. FORCE SHALL BE LESS THAN ALLOWABLE
SHEAR FORCE INDUCED ON FASTENER OR MOUNTING DEVICE FROM
- 250 LB. SHEAR STRESS
- 250 LB. BENDING MOMENT
THE FOLLOWING STRUCTURAL STRENGTHS:
GRAB BARS ARE TO BE CONSTRUCTED AND INSTALLED TO MEET
OF THE ARCHITECTURAL BARRIERS ACT (ABA).
AND OTHER FIXTURES AND ITEMS SHALL MEET THE REQUIREMENTS
INSTALLATION OF ACCESSIBLE TOILET AND BATH ACCESSORIES
ACCESSORIES, FOR SELECTED MODEL INFORMATION.
SEE SPECIFICATION SECTION 10 28 13, TOILET AND BATH
OF DOOR
1.
2.
NOTES:
RESTROOM SIGN FORMATS
BRAILLE
GRADE 2
WOMEN
SIGN TYPE AS SCHEDULED SIGN TYPE AS SCHEDULED
MEN
ALL DOOR NAMEPLATES IN A BUILDING WILL BE THE SAME FINAL SIZE. .
OF THE SUBCONTRACTOR.
GRAPHIC DESIGN OF THE SIGN AND FINAL SIZES OF SIGNS ARE THE RESPONSIBILITY
ESTABLISH THE DESIRED MESSAGE AND APPLICATION FOR EACH SIGN. THE EXACT
PROJECT ARE IN THE PROPER OSHA OR ADA FORMAT. THIS DRAWING IS MEANT TO
SIGN SUBCONTRACTOR IS RESPONSIBLE TO MAKE SURE ALL SIGNS USED ON THIS
OF ALL DOUBLE DOOR LOCATIONS
MOUNT SIGNS ON RIGHT HAND DOOR
FRAME
FACE
SYMBOL
TEXT
1/2"R 1/2"R
1"
1/2"
1"
1/2"
1/8"
4"
1/8"
NO SCALE
SIGN MOUNTING LOCATIONS
SIGNAGE
T O F
IN
IS
H F
L O
O R
O F T
A C
K T
IL
E C
H A
R A
C T
F
R O
M B
A S
E L
IN
LATCH SIDE
8" 8"
ADA RESTROOM SIGNAGE, SEE DETAIL 1, THIS SHEET7.
2" x 2" x 48" SATIN STAINLESS STEEL CORNER GUARD6.
SERVICE SINK, SEE 1/P-500 ON PLUMBING DRAWINGS5.
NO WORK REQUIRED
CLEAR FLOOR SPACE FOR ACCESSIBILITY COMPLIANCE. 4.
TILE TRANSITION STRIP3.
EXISTING WALL
FINAL FACE OF NEW FINISH TO MATCH FINAL FINISH OF 2.
INFILL DOOR OPENING, SEE A-112 AND A-1141.
LICENSED
A RCHITECT
STA TE OF IDAHO
A R-916427 s ig n e d b y
C h e ck e d b y
D ra w n b y
C a d F il e
D a te
P ro je ct
C H
M H
IL
L
S y m b o l
A p p ro v D a te
D e s c ri p ti o n
Drawing Number:
A B C D E F G H
GUNFIGHTERS
HOME OF THE
COMBAT COMMAND
AIR
DEPARTMENT OF
MOUNTAIN HOME AFB.
THE AIR FORCE
MOUNTAIN HOME
AFB
U.S. AIR FORCE
366 CES/CECD
1030 LIBERATOR ST.
MOUNTAIN HOME AFB, ID
83648-5442
E a s t F ro n t S tr e et
S u it e
5A -4
2.
d g n
S p e c
P ro je ct
B o is e I d a h o
2-
FILENAME: PLOT DATE: PLOT TIME:2019\04\24 2:19:37 PM
SHEET of
/2
/2
F A
C
IL
IT
Y
Z
H
-8
R E P
A
IR
S
Q U
A D O
P S
C E
R T
IF
IE
D F
IN
A L D
E S
A-402
E S
E
IG
H
D D
A L S
O G
L
IO
A R
C H
IT
E C
T U
R A
L
682783_2215A-402.dgn
IN
T E
R
IO
R E
L E
V A
T
IO
N S
1/4"=1'-0"
WALL ELEVATION - RM 165
1/4"=1'-0"
WALL ELEVATION - RM 165
1/4"=1'-0"
WALL ELEVATION - RM 165
1/4"=1'-0"
WALL ELEVATION - RM 165
1/4"=1'-0"
WALL ELEVATION - RM 166
1/4"=1'-0"
WALL ELEVATION - RM 166
1/4"=1'-0"
WALL ELEVATION - RM 166
1/4"=1'-0"
WALL ELEVATION - RM 166
1/4"=1'-0"
WALL ELEVATION - RM 166
1/4"=1'-0"
WALL ELEVATION - RM 166
PTD-1
P
TPD
WC
SD
LAV
P
P
WC
LAV
SD
SD
LAV
SD
LAV
P P
URINAL
SURINAL
PTD-1
SD
LAV
WC
TPD
A-401 A-401 A-401 A-401
A-401 A-401 A-401 A-401
A-401 A-401
1/4"=1'-0"
WALL ELEVATION - RM 103
A-401
3/8"=1'-0"
IP
12 x 24 FIELD TILE
SCHLUTER METAL TRIM
12 x 12 ACCENT TILE
SCHLUTER METAL TRIM
12 x 24 FIELD TILE
FLOOR LINE
CEILING LINE
DF
FILLER
BOTTLE
SEE PLAN
CORNER GUARD,
TYP
IP,
TYP
IP,
IP
GB-3
TPD
WC
RESTROOM WALL TILE PATTERN
37 149
C F
IL
A N
O W
IC
Z
GB-3
TPD
P
ABA ABA
MG
MG
MG
MG
MG
(TYPICAL ALL WALLS)
LICENSED
A RCHITECT
STA TE OF IDAHO
A R-916427 s ig n e d b y
C h e ck e d b y
D ra w n b y
C a d F il e
D a te
P ro je ct
C H
M H
IL
L
S y m b o l
A p p ro v D a te
D e s c ri p ti o n
Drawing Number:
A B C D E F G H
GUNFIGHTERS
HOME OF THE
COMBAT COMMAND
AIR
DEPARTMENT OF
MOUNTAIN HOME AFB.
THE AIR FORCE
MOUNTAIN HOME
AFB
U.S. AIR FORCE
366 CES/CECD
1030 LIBERATOR ST.
MOUNTAIN HOME AFB, ID
83648-5442
E a s t F ro n t S tr e et
S u it e
5A -4
3.
d g n
S p e c
P ro je ct
B o is e I d a h o
2-
FILENAME: PLOT DATE: PLOT TIME:2019\04\24 2:21:27 PM
SHEET of
/2
/2
F A
C
IL
IT
Y
Z
H
-8
R E P
A
IR
S
Q U
A D O
P S
C E
R T
IF
IE
D F
IN
A L D
E S
A-403
E S
E
IG
H
D D
A L S
O G
L
IO
A R
C H
IT
E C
T U
R A
L
682783_2215A-403.dgn
IN
T E
R
IO
R E
L E
V A
T
IO
N S
1/4"=1'-0"
WALL ELEVATION - RM 121
1/4"=1'-0"
WALL ELEVATION - RM 121
1/4"=1'-0"
WALL ELEVATION - RM 121
1/4"=1'-0"
1/4"=1'-0"
WALL ELEVATION - RM 122
1/4"=1'-0"
WALL ELEVATION - RM 122
1/4"=1'-0"
WALL ELEVATION - RM 122
1/4"=1'-0"
WALL ELEVATION - RM 122
1/4"=1'-0"
WALL ELEVATION - RM 164
1/4"=1'-0"
WALL ELEVATION - RM 137
KEYED NOTESX
WALL ELEVATION - 121
(3) TOTAL
2'-4"1'-6"3'-0"1'-6"3'-0"3'-0"
2'-4"1'-6"3'-0"1'-6"3'-0"3'-0" 3'-0" 1'-6"
1'-6"3'-0"
PTD-1
SD
LAV
LAV
SD
P
P
P
WC
URINAL
PTD-1
LAV
SD
SD
LAV
IP
IP
P
GB-3
TPD WC
TPD
P
URINAL URINAL
S
B C BAA
A-404
SINK
SINK
A
A-404
SIM
SIM
DF
A-404A-404 A-404 A-404
IP, TYP
IP, TYP
A-401 A-401 A-401 A-401
A-401 A-401 A-401 A-401
A-112 A-113
38 149
C F
IL
A N
O W
IC
Z
WC
TPD
GB-3
GB-3
1/4"=1'-0"
A-114
LOCKER WALL
WALL ELEVATION SECTION
LOCKERS
FLOOR FINISH
METAL STUD
CEILING
SUSPENDED
AT 24" 0.C.
METAL STUD BRACE
CMU WALL
EXISTING
METAL TRACK
LOCKERS
CLIP
TRIM SUPPORT
CONT. METAL
GYPSUM BOARD
1x8 TRIM
1x8 TRIM
ABA
INSTALLED
MICROWAVE, FURNISHED BY OTHERS, CONTRACTOR 3.
INSTALLED
REFRIGERATOR, OWNER FURNISHED CONTRACTOR 2.
INSTALLED
ICE MAKER, OWNER FURNISHED CONTRACTOR 1.
MG
MG
MG
MG
LICENSED
A RCHITECT
STA TE OF IDAHO
A R-916427 s ig n e d b y
C h e ck e d b y
D ra w n b y
C a d F il e
D a te
P ro je ct
C H
M H
IL
L
S y m b o l
A p p ro v D a te
D e s c ri p ti o n
Drawing Number:
A B C D E F G H
GUNFIGHTERS
HOME OF THE
COMBAT COMMAND
AIR
DEPARTMENT OF
MOUNTAIN HOME AFB.
THE AIR FORCE
MOUNTAIN HOME
AFB
U.S. AIR FORCE
366 CES/CECD
1030 LIBERATOR ST.
MOUNTAIN HOME AFB, ID
83648-5442
E a s t F ro n t S tr e et
S u it e
5A -4
4.
d g n
S p e c
P ro je ct
B o is e I d a h o
2-
FILENAME: PLOT DATE: PLOT TIME:2019\04\24 2:23:30 PM
SHEET of
/2
/2
F A
C
IL
IT
Y
Z
H
-8
R E P
A
IR
S
Q U
A D O
P S
C E
R T
IF
IE
D F
IN
A L D
E S
A-404
E S
E
IG
H
D D
A L S
O G
IO
C H
IT
E C
T U
R A
L
A 3/4"=1'-0"
2'-0"
B 3/4"=1'-0"
2'-0"
C 3/4"=1'-0"
X
1'-0"
TYPICAL CABINET M-WAVE CABINETDRAWER CABINET
2'-0"
(S E
E A
N D
A -4
3)
1'-8"
(VERIFY)
(D E
T A
IL
A T
H
IS
S
H E
E T
(DETAIL A THIS SHEET)
1 1/2 "
/2
1 1/2 "
/2
1 1/2 "
/2
CABINET KEYNOTES
IN
T E
R
IO
R E
L E
V A
T
IO
N S A
N D D
E T A
IL
S
682783_2215A-404.dgn
C F
IL
A N
O W
IC
Z
PROVIDED BY OTHERS
MICROWAVE , (3) TOTAL. 13.
FLOOR LINE12.
BASE AS SPECIFIED11.
3/4" CABINET DOOR10.
DRAWER FACE9.
INTERMEDIATES
3/4" SIDES, BOTTOM AND 8.
FACE OF FINISHED WALL7.
GLIDES
FULL EXTENSION DRAWER 6.
SPLASH
3/4" SOLID SURFACE BACK 5.
ROUNDOVER
1 1/2" SOLID SURFACE 4.
COUNTERTOP
3/4" SOLID SURFACE 3.
BACK
1/4" TEMPERED HARD BOARD 2.
CABINET LINER
ADJUSTABLE SHELVES W/ 1.
LICENSED
A RCHITECT
STATE OF IDAHO
A R-916427 s ig n e d b y
C h e ck e d b y
D ra w n b y
C a d F il e
D a te
P ro je ct
C H
M H
IL
L
S y m b o l
A p p ro v D a te
D e s c ri p ti o n
Drawing Number:
A B C D E F G H
GUNFIGHTERS
HOME OF THE
COMBAT COMMAND
AIR
DEPARTMENT OF
MOUNTAIN HOME AFB.
THE AIR FORCE
MOUNTAIN HOME
AFB
U.S. AIR FORCE
366 CES/CECD
1030 LIBERATOR ST.
MOUNTAIN HOME AFB, ID
83648-5442
E a s t F ro n t S tr e et
S u it e
5A -5
1.
d g n
S p e c
P ro je ct
B o is e I d a h o
2-
FILENAME: PLOT DATE: PLOT TIME:2019\04\24 2:26:24 PM
SHEET of
/2
/2
F A
C
IL
IT
Y
Z
H
-8
R E P
A
IR
S
Q U
A D O
P S
C E
R T
IF
IE
D F
IN
A L D
E S
3" = 1'-0"
3" = 1'-0"
3" = 1'-0"
D O
O R W
ID
T
H
D O
O R H
E
IG
H T
/4 U
N L E
S S N
O T E
D
DOOR SILL
DOOR AS SCHEDULED
HM FRAME
3" = 1'-0"
3" = 1'-0"
3" = 1'-0"
W+1"
METAL STUDS
D O
O R H
E
IG
H T
FRAME
HOLLOW METAL
DOOR AS SCHEDULED,
1/2 "
W+1"
W
METAL STUDS
5/8" GYPSUM BOARD
ANCHORS
STANDARD JAMB
MANUFACTURER'S
FLOOR LINE
SCHEDULED
FLOORING AS
DOOR AS SCHEDULED
S C
H E
D U
L E
O T
H E
R W
IS
E O
N
3/4 "5 3/4 "
3/4 "5 3/4 "
D O
O R H
E
IG
H T
EXTERIOR
SCHEDULED
DOOR SHOE AS
DOOR AS SCHEDULED
IN SEALANT
SCHEDULED, SET
THRESHOLD AS
SCHEDULED
FLOOR FINISH AS
D O
O R H
E
IG
H T
D O
O R W
ID
T
H
3"=1'-0"
DOOR JAMB - H.M.
3"=1'-0"
DOOR SILL
3"=1'-0"
DOOR HEAD - H.M.
DOOR JAMB - H.M.
W
3"=1'-0"
3"=1'-0"
3"=1'-0"
SLAB, SEE CIVIL
PAVING OR CONC.
SCHEDULED
DOOR AS
SCHEDULED
RAINDRIP WHERE
EXISTING CMU
BOTH SIDES
AROUND
SEALANT, ALL
INSULATION
EXISTING WALL
FRAMING
EXISTING METAL
GWB
REPAIR
STUD FRAM'G
NEW METAL
EXISTING CMU
INSULATION
EXISTING WALL
FRAMING
EXISTING METAL
GWB
REPAIR
STUD FRAM'G
NEW METAL
DOOR HEAD - H.M.
7'-4" A.F.F.
WALL BOARD
NEW GYPSUM
EXISTING CMU
BOTH SIDES
AROUND
SEALANT, ALL
ANCHORS
STANDARD JAMB
MANUFACTURER'S
SCHEDULED
DOOR AS
GROUT HEAD SOLID
HOLLOW METAL FRAME
THERMALLY BROKEN
SEALANT
WALL BOARD
NEW GYPSUM
GWB
REPAIR
STUD FRAM'G
NEW METAL
GWB
REPAIR
STUD FRAM'G
NEW METAL
WALL BOARD
NEW GYPSUM
EXISTING CMU
EXISTING CMU
GWB
REPAIR
INSULATION
EXISTING WALL
FRAMING
EXISTING METAL
INSULATION
EXISTING WALL
FRAMING
EXISTING METAL
EXISTING CMU
INSULATION
EXISTING WALL
FRAMING
EXISTING METAL
GWB
REPAIR
STUD FRAM'G
NEW METAL
WALL BOARD
NEW GYPSUM
SEALANT
GWB
REPAIR
STUD FRAM'G
NEW METAL
WALL BOARD
NEW GYPSUM
EXISTING CMU
WALL BOARD
NEW GYPSUM
SEALANT
EXISTING CMU
GWB
REPAIR
STUD FRAM'G
NEW METAL
INSULATION
EXISTING WALL
FRAMING
EXISTING METAL
TRANSLUCENT PANEL - HEAD
TRANSLUCENT PANEL - JAMB
TRANSLUCENT PANEL - SILL
3/4 "
3/4 "
3/4 "
TRANSLUCENT PANEL
TRANSLUCENT PANEL
TRANSLUCENT PANEL
SEALANT
1/2 "
STUD FRAM'G
NEW METAL
WALL BOARD
NEW GYPSUM
SEALANT
GROUT HEAD SOLID
HOLLOW METAL FRAME
THERMALLY BROKEN
EXISTING R.O.
(VERIFY)
EXISTING LOUVER
OPENING, VERIFY
SEALANT
SEALANT
FASTENERS
SHIMS AND
SEALANT
SEALANT
FASTENERS
SHIMS AND
3/4 "
3/4 "
TO DRAIN
SLOPE FLASHING
SEALANT
3/4 "
SILL FLASHING
PREFINISHED
SILL FLASHING
PREFINISHED
TO DRAIN
FLASHING
SLOPE
SEALANT
SEALANT
SEALANT
SEALANT
P A
N E
L H
E
IG
H T
R .O
P A
N E
L W
ID
T
H
R .O
P A
N E
L H
E
IG
H T
R .O
W
IN
D O
W W
ID
T
H
R .O
W
IN
D O
W H
E
IG
H T
R .O
W
IN
D O
W H
E
IG
H T
R .O
WINDOW SILL
SOLID SURFACE
REQUIRMENTS
WINDOW MFR'S
FASTENERS PER
SPECIFIED.
AND GLAZING AS
WINDOW FRAMES
BLAST RESISTANT
REQUIRMENTS
WINDOW MFR'S
FASTENERS PER
SPECIFIED.
AND GLAZING AS
WINDOW FRAMES
BLAST RESISTANT
REQUIRMENTS
WINDOW MFR'S
FASTENERS PER
SPECIFIED.
AND GLAZING AS
WINDOW FRAMES
BLAST RESISTANT
WINDOW HEAD
WINDOW JAMB
WINDOW SILL
A-501
E S
E
IG
H
D D
A L S
O G
C H
IT
E C
T U
R A
L
682783_2215A-501.dgn
D O
O R A
N D W
IN
D
O W D
E T A
IL
S
C F
IL
A N
O W
IC
Z
LICENSED
A RCHITECT
STA TE OF IDAHO
A R-916427 s ig n e d b y
C h e ck e d b y
D ra w n b y
C a d F il e
D a te
P ro je ct
C H
M H
IL
L
S y m b o l
A p p ro v D a te
D e s c ri p ti o n
Drawing Number:
A B C D E F G H
GUNFIGHTERS
HOME OF THE
COMBAT COMMAND
AIR
DEPARTMENT OF
MOUNTAIN HOME AFB.
THE AIR FORCE
MOUNTAIN HOME
AFB
U.S. AIR FORCE
366 CES/CECD
1030 LIBERATOR ST.
MOUNTAIN HOME AFB, ID
83648-5442
E a s t F ro n t S tr e et
S u it e
5A -5
2.
d g n
S p e c
P ro je ct
B o is e I d a h o
2-
FILENAME: PLOT DATE: PLOT TIME:2019\04\24 2:28:11 PM
SHEET of
/2
/2
F A
C
IL
IT
Y
Z
H
-8
R E P
A
IR
S
Q U
A D O
P S
C E
R T
IF
IE
D F
IN
A L D
E S
3" = 1'-0"
3" = 1'-0"
3" = 1'-0" 3" = 1'-0"
3" = 1'-0"
3" = 1'-0"
1 2 3"=1'-0"
3"=1'-0"
NOT USED
3"=1'-0"
DOOR HEAD - H.M.
DOOR JAMB - H.M.
3/4 "5 3/4 "
D O
O R H
E
IG
H T
SCHEDULED
DOOR AS
EXISTING CMU
BOTH SIDES
AROUND
SEALANT, ALL
3/4 "5 3/4 "
D O
O R W
ID
T
H
EXISTING CMU
BOTH SIDES
AROUND
SEALANT, ALL
ANCHORS
STANDARD JAMB
MANUFACTURER'S
SCHEDULED
DOOR AS
FRAME
HOLLOW METAL
FRAME
HOLLOW METAL
3"=1'-0"
3"=1'-0"
3"=1'-0"
1/2 "
D O
O R H
E
IG
H T
DOOR AS SCHEDULED,
W
5/8" GYPSUM BOARD
W
D O
O R W
ID
T
H
W+1"
METAL STUDS
METAL STUDS
DOOR AS SCHEDULED
ANCHORS
STANDARD JAMB
MANUFACTURER'S
5/8" GYPSUM BOARD
DOOR AS SCHEDULED
FOAM
FILL W/ SOUND ATTENUATION
HOLLOW METAL FRAME,
ISOLATOR
SOLID NEOPRENE SOUND
FOAM
FILL W/ SOUND ATTENUATION
HOLLOW METAL FRAME,
STC DOOR ASSEMBLY
THRESHOLD INCLUDED IN
SCHEDULED
STC DOOR BOTTOM AS
SCHEDULED
FLOORING AS
FLOOR LINE
W+1"
STC45 RATED DOOR HEAD - H.M.
STC45 RATED DOOR JAMB - H.M.
STC45 RATED DOOR SILL
EXISTING R.O.
(VERIFY)
3/4 "5 3/4 "D O
O R H
E
IG
H T
EXISTING CMU
BOTH SIDES
AROUND
SEALANT, ALL
EXISTING R.O.
(VERIFY)
3/4 "5 3/4 "D O
O R W
ID
T
H
EXISTING CMU
BOTH SIDES
AROUND
SEALANT, ALL
ANCHORS
STANDARD JAMB
MANUFACTURER'S
FRAME
HOLLOW METAL
FRAME
HOLLOW METAL
SCHEDULED
DOOR AS
SCHEDULED
DOOR AS
STC45 RATED DOOR HEAD - H.M.
STC45 RATED DOOR JAMB - H.M.
FLOOR LINE
SCHEDULED
FLOORING AS
SWEEP
IN BED OF SEALANT
THRESHOLD SET
EXISTING CMU
INSULATION
EXISTING WALL
FRAMING
EXISTING METAL
GWB
REPAIR
STUD FRAM'G
NEW METAL
EXISTING CMU
WALL BOARD
NEW GYPSUM
GWB
REPAIR
STUD FRAM'G
NEW METAL
INSULATION
EXISTING WALL
FRAMING
EXISTING METAL
EXISTING R.O.
(VERIFY)
WALL BOARD
NEW GYPSUM
FASTENERS
SHIMS AND
3/4 "
DOOR JAMB - ALUMINUM
DOOR HEAD - ALUMINUM
DOOR SILL - ALUMINUM
3/4 "
FASTENERS
SHIMS AND
SEALANT
NOT USED
AS SPECIFIED
AND GLAZING
DOOR, FRAME,
BLAST RESISTANT
SEALANT
SEALANT
SEALANT
AS SPECIFIED
AND GLAZING
DOOR, FRAME,
BLAST RESISTANT
AS SPECIFIED
AND GLAZING
DOOR, FRAME,
BLAST RESISTANT
A-502
E S
E
IG
H
D D
A L S
O G
C H
IT
E C
T U
R A
L
682783_2215A-502.dgn
D O
O R D
E T A
IL
S
C F
IL
A N
O W
IC
Z
LICENSED
A RCHITECT
STA TE OF IDAHO
A R-916427 s ig n e d b y
C h e ck e d b y
D ra w n b y
C a d F il e
D a te
P ro je ct
C H
M H
IL
L
S y m b o l
A p p ro v D a te
D e s c ri p ti o n
Drawing Number:
A B C D E F G H
GUNFIGHTERS
HOME OF THE
COMBAT COMMAND
AIR
DEPARTMENT OF
MOUNTAIN HOME AFB.
THE AIR FORCE
MOUNTAIN HOME
AFB
U.S. AIR FORCE
366 CES/CECD
1030 LIBERATOR ST.
MOUNTAIN HOME AFB, ID
83648-5442
E a s t F ro n t S tr e et
S u it e
5A -5
3.
d g n
S p e c
P ro je ct
B o is e I d a h o
2-
FILENAME: PLOT DATE: PLOT TIME:2019\04\24 2:31:49 PM
SHEET of
/2
/2
F A
C
IL
IT
Y
Z
H
-8
R E P
A
IR
S
Q U
A D O
P S
C E
R T
IF
IE
D F
IN
A L D
E S
BREAK SHAPE DETAIL
1 1/2" = 1'-0"
A-503
E S
E
IG
H
D D
A L S
O G
C H
IT
E C
T U
R A
L
682783_2215A-503.dgn
M
IS
C
D E
T A
IL
S
3/8"=1'-0"
FLOOR SLAB
CONCRETE
EXISTING
CORRIDOR
LID FRAMING
METAL STUD BOARD, TYP
5/8" GYPSUM WALL
BOARD, TYP
5/8" GYPSUM WALL
FRAMING
METAL STUD WALL
FLOOR SLAB
EXISTING CONCRETE
FLOOR SYSTEM
EXISTING ACCESS
FLOOR SYSTEM
EXISTING ACCESS
CEILING
SUSPENDED
SCHEDULED
FLOORING AS
EXISTING METAL ROOF DECK
EXISTING ROOF GIRDER/TRUSS
NOT SHOWN
ADJACENT CEILINGS
NOTE:
NEW ROOF SYSTEM
3/8"=1'-0"
AC112
SKYLIGHT EXIT CORRIDOR
NEW SKYLIGHT
TRUSS
EXISTING ROOF GIRDER/
CEILING
SUSPENDED
SCHEDULED
FLOORING AS
3/8"=1'-0"
3/8"=1'-0"
EXISTING METAL ROOF DECK
CEILING
NEW SUSPENDED
EXISTING PARTITION WALL
SCHEDULED
NEW FLOORING AS
FLOOR SYSTEM
EXISTING ACCESS
WALL FRAMING
NEW METAL STUD
INTERIOR SOUND WALL
BOARD EA. SIDE
5/8" GYPSUM WALL
TYPES
A-001 FOR WALL
STRUCTURE, SEE
WALL TYPE J TO
WALL FRAMING,
NEW METAL STUD
682783
BOARD, TYP
5/8" GYPSUM WALL
INSULATION (R-13)
3 1/2" SOUND BATT
BOARD, TYP
5/8" GYPSUM WALL
ABOVE CEILING
BOARD, EXREND 6"
5/8" GYPSUM WALL
CEILING
SUSPENDED
/2
WALL FRAMING
3 5/8" METAL STUD
BOTTOM OF WALL
SKYLIGHT OPENING
BOARD, TYP
5/8" GYPSUM WALL
FLOOR INSPECTION COVER
1 1/2"=1'-0"
NEW ROOF SYSTEM
DECK
EXISTING METAL ROOF
NEW ROOF SYSTEM
FOR PADLOCK REMOVED
2' x 2' ACUDOR W/ STAPLE
NEW FLOORING AS SCHEDULED
EXISTING ACCESS FLOOR SYSTEM
PEDESTALS
INTERFERE W/SUPPORT
POSITIONED AS NOT TO
ACCESS COVER TO BE
NOTE:
A-112
A-511
STRUCTURE AS REQ'D.
FRAMING, BRACE TO
3 5/8" METAL STUD WALL
PLAN
NEW WINDOW
3" MIN
FROM ABOVE
DOWNSPOUT
EXISTING WALL
OR DOOR AS OCCURS
TO CLEAR WINDOW
ADJUST DOWNSPOUT
DOWNSPOUT
EXISTING WALL
SCUPPER
HEAD
COLLECTOR
COPING
NEW WINDOW
3" MIN
/4
/4
SCUPPER
SECTIONELEVATIONELEVATION
COLLECTOR HEAD AND DOWNSPOUT
SPLASHBLOCK
EXISTING
DRAIN OUTLET
EXISTING ROOF
DRAIN OUTLET
EXISTING ROOF
SPLASHBLOCK
SPLASHBLOCK
EXISTING
A-150
A-113, A-114, A-111, A-112
DOWNSPOUT
EXISTING WALL
A-111A-113
DOORS IS SIMILAR
DOWNSPOUTS AT
NOTE:
DOORS IS SIMILAR
DOWNSPOUTS AT
NOTE:
4" x 6" DOWNSPOUT
WALL ELEVATIONS AND SECTION
10/A-510
9/A-510 AND
HEAD, SEE
COLLECTOR
3/4"=1'-0"
WALL TYPE A
MODIFY AS REQ'D.
FLOOR SYSTEM,
RAISED ACCESS
ACOUSTICAL SEALANT
METAL STUDS
SYSTEM AS REQ'D.
FLOOR SUPPORT
EXISTING ACCESS
THRESHOLDAS SCHEDULED
FLOOR FINISH
3/4"=1'-0"
1 1/2" METAL DECK
2" CONCRETE OVER
STUDS AT 16" O.C.
4" 18GA METAL
EXISTING
BOTTOM OF DECK
STOP WELDED TO
LIGHT GA. POUR
AS SCHEDULED
DOOR AND FRAME
FLOOR INFILL AT NEW WALL/DOOR
A-111
C F
IL
A N
O W
IC
Z
1 1/2"=1'-0"
PLATFORM FLOOR FRAMING
SLAB
EXISTING CONCRETE
O.C.
CHANNELS AT 12"
10" 16 GA STEEL
PLYWOOD
3/4" FIRE TREATED
FINISHES IN ROOM
TO MATCH FLOOR
FINISHED FLOORING
STADIUM SEATING LAYOUT
NTS
(TYP) (TYP)
ADA
MIN.
30"
MIN.
30"
M
IN
(T
Y P
(T Y P
M
IN
4"
V A
R
IE
S
4"
COPING CAP
NEW METAL
BREAK SHAPE
NEW METAL
UNDER BREAK SHAPE
BUTYL SEALANT
BREAK SHAPE AND SEAL
SAW KERF CMU FOR
LICENSED
A RCHITECT
STA TE OF IDAHO
A R-916427 s ig n e d b y
C h e ck e d b y
D ra w n b y
C a d F il e
D a te
P ro je ct
C H
M H
IL
L
S y m b o l
A p p ro v D a te
D e s c ri p ti o n
Drawing Number:
A B C D E F G H
GUNFIGHTERS
HOME OF THE
COMBAT COMMAND
AIR
DEPARTMENT OF
MOUNTAIN HOME AFB.
THE AIR FORCE
MOUNTAIN HOME
AFB
U.S. AIR FORCE
366 CES/CECD
1030 LIBERATOR ST.
MOUNTAIN HOME AFB, ID
83648-5442
E a s t F ro n t S tr e et
S u it e
5A -5
0.
d g n
S p e c
P ro je ct
B o is e I d a h o
2-
FILENAME: PLOT DATE: PLOT TIME:2019\04\24 2:49:29 PM
SHEET of
/2
/2
F A
C
IL
IT
Y
Z
H
-8
R E P
A
IR
S
Q U
A D O
P S
C E
R T
IF
IE
D F
IN
A L D
E S
A-201
1 42 1 1/2" = 1'-0" 1 1/2" = 1'-0"
1 1/2" = 1'-0"
1 1/2"=1'-0"
TOP OF WALL AND CRICKET TOP OF SIDE WALL AND ROOF
2"
ROOF RIDGE
1 1/2"=1'-0" 1 1/2"=1'-0"
ROOF INSULATION TRANSITION ROOF AT SLOPE CHANGE
1 1/2"=1'-0" 1 1/2"=1'-0"
ROOF EXPANSION JOINT
COPING CAP
1/2" CEMENT BOARD
EPDM ROOFING SYSTEM
WRAPPED OVER NAILER
COPING HOLD
DOWN CLEAT
EXISTING
CMU WALL
COPING CAP
1/2" CEMENT BOARD
EPDM ROOFING SYSTEM
WRAPPED OVER NAILER
COPING HOLD
DOWN CLEAT
EXISTING
CMU WALL
COPING HOLD
DOWN CLEAT
COPING HOLD
DOWN CLEAT
EPDM EDGE FLASHING
1/2" COVER
BOARD
1/2" COVER
BOARD
EPDM ROOFING
SYSTEM
RIGID INSUL.
SEE A-150
EXISTING STRUCTURE
EXISTING METAL DECK
EXISTING STRUCTURE
EXISTING METAL DECK
NEW CMU PARAPET EXTENSION
" 5
"COPING HOLD
DOWN CLEAT
NEW CMU
EXISTING
CMU WALL
1/2" CEMENT BOARD
EPDM ROOFING SYSTEM
WRAPPED OVER NAILER
COPING CAP
COPING HOLD
DOWN CLEAT
EPDM EDGE FLASHING
EPDM EDGE FLASHING
EPDM ROOFING
SYSTEM
RIGID INSUL.
SEE A-150
EPDM ROOFING
SYSTEM
1/2" COVER
BOARD
1/2" COVER
BOARD
EPDM EDGE FLASHING
EPDM ROOFING
SYSTEM
WIDTH
CMU WALL
EXISTING
BELLOW FLASHINGEPDM FLASHING
UNDER BELLOW
JOINT
1/2" CEMENT
BOARD
SLOPED WOOD
NAILER, EA SIDE
EXISTING CMU
INTERIOR WALL
3 5/8" METAL WALL
FRAMING AT 24" O.C.
EXISTING METAL DECK
RIGID INSUL.
SEE A-150
M
IN
1/2" COVER
BOARD
EXISTING METAL DECK
EXISTING CMU
INTERIOR WALL
EPDM ROOFING
SYSTEM
ROOF EXPANSION JOINT
BEYOND, SEE DETAIL 4
THIS SHEET
EXISTING METAL DECK
EPDM EDGE FLASHING
EPDM ROOFING
SYSTEM
1/2" COVER
BOARD
RIGID INSUL.
SEE A-150
EXISTING METAL
DECK
EXISTING
STRUCTURE
RIGID INSUL.
SEE A-150
EXISTING METAL
DECK
EXISTING
STRUCTURE
EXISTING CMU
INTERIOR WALL
RIGID INSULATION, TRANSITION
INSULATION TO BUILD UP ROOF
SLOPE TO ALIGN WITH RIGID
INSULATION
RIGID INSULATION, TRANSITION
INSULATION TO BUILD UP ROOF
SLOPE TO ALIGN WITH RIGID
INSULATION AT ROOF SLOPE
CHANGE AS INDICATED ON
DETAIL 7 THIS SHEET
ROOF SLOPE CHANGE 8
EXISTING METAL
DECK
EXISTING CMU
INTERIOR WALL
EPDM EDGE FLASHING
RIGID INSUL.
SEE A-150
1/2" COVER
BOARD
EPDM ROOFING
SYSTEM
SEE DETAL
8 THIS SHEET
3 5/8" METAL WALL
FRAMING AT 24" O.C.
BELLOW FLASHING
1/2" CEMENT
BOARD
SEAL BELLOW
FLASHING END
EXISTING
CMU WALL
NEW COPING
BELLOW FLASHING,
SEE DETAIL 8 THIS
SHEET
3"
INTERNAL WALL AND ROOF
1 1/2"=1'-0"
AT COPING
1 1/2"=1'-0"
1 1/2"=1'-0"
COVER WALL END
WITH FLASHING
SIMILAR TO COPING
SEAL FLASHING
EDGES
SEAL FLASHING
EDGES
EXISTING
INTERNAL
CMU WALL
INTERIOR CMU WALL AND ROOF
6"
4"8" x 8" SCUPPER
SEAL ALL
EDGES
COLLECTOR HEAD
1'-0" 1 1/2 "
1'- 0"
1'-4"
8" x 8" SCUPPER
1 1/2 "
SEALANT
COPING CAP
BEYOND
EPDM EDGE FLASHING
1/2" CEMENT BOARD
RIGID INSUL.
SEE A-150
EXISTING
NEW ROOF DRAIN AT
EXISTING LOCATION,
SEE PLUMBING
M
IN
EXISTING
STRUCTURE
EXISTING SCUPPER
OPENING
COLLECTOR HEAD AND SCUPPER
4"
COLLECTOR HEAD, OVERFLOW SCUPPER AND ROOF DRAIN
1/2" COVER
BOARD
3" MIN. RIGID
INSULATION
EPDM ROOFING
SYSTEM
SLOPED WOOD NAILER, EA SIDE
EPDM FLASHING UNDER
BELLOW JOINT
(2) #4 HORIZONTAL
REBAR AT TOP OF
CMU WALL
NOTE:
1. FOR CMU REQUIREMENTS
SEE DRAWING S-001 GENERAL
STRUCTURAL NOTES
RIGID INSUL.
SEE A-150
EXISTING METAL DECK
EXISTING STRUCTURE
A-150 A-150
A-201
A-150, A-201 A-150, A-201
A-150
A-201
A-150, A-201A-150
A-201
A-150
A-201
A-150
A-201
A-150 A-201
#4 VERTICAL REBAR
ADHESIVE DOWEL
AT 32" O.C. W/
4 1/2" EMBED
(CENTER IN WALL)
COLLECTOR HEAD,
22 GA. PREFINISHED
4" x 6" DOWNSPOUT, 22 GA. PREFINISHED
TAPERED
INSULATION
TAPERED
INSULATION
CRICKET,
SEE A-150
RIGID INSUL.
SEE A-150
EXISTING STRUCTURE
GYP THERMAL