Phase 2 - Bldg 331 Renovation - Plans.pdf
PDF 8 MB Posted
- Solicitation number
- W912DS25BA004
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET ID
AI
R
F O
R C
E C
IV
IL
E N
G
IN
EE
R
IN
G
C
EN
TE
R
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
VOLUME:
M
AR
K D
ES
C
R
IP
TI
O
N
Fi le
P at h:
Pl ot D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
D C
AV
IN
Au to de sk
D oc s:
//0
9-
-J
BM
D
L B3
B
2/
JB
M
D L
1_
La b
Ex pa ns io n_ A2
3.
rv t 1/
/2
:5
1:
A M
G-000B
C O
VE
R
S H
EE
T
JO
IN
T
BA
SE
M
C G
U
IR
E- D
IX
-L
AK
EH
U R
ST
, L
AK
EH
U R
ST
N
J D
R
EM
Y
G U
EC
KE
R
Q R
EM
Y
JA
N
U
AR
Y
M
SB
L
-4
MSBL 12-4029
JANUARY 2025
JOINT BASE MCGUIRE-DIX-LAKEHURST, LAKEHURST NJ
FINAL SUBMITTAL - ISSUED FOR CONSTRUCTION
B3
R
EN
O
VA
TI
O
N
B331 RENOVATION
R
F O
R C
E C
IV
IL
E N
G
IN
EE
R
IN
G
C
EN
TE
R
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Fi le
P at h:
Pl ot D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
D R
EM
Y
Au to de sk
D oc s:
//0
9-
-J
BM
D
L B3
B
2/
JB
M
D L
1_
La b
Ex pa ns io n_ A2
3.
rv t 1/
/2
:5
1:
A M
G-001B
D R
AW
IN
G
IN
D
EX
JO
IN
T
BA
SE
M
C G
U
IR
E- D
IX
-L
AK
EH
U R
ST
, L
AK
EH
U R
ST
N
J D
R
EM
Y
G U
EC
KE
R
Q R
EM
Y
JA
N
U
AR
Y
M
SB
L
-4
FI
N
AL
S
U
BM
IT
TA
L
- I
SS
U
ED
F
O R
C O
N
ST
R U
C
TI
O N
B3
R
EN
O
VA
TI
O
N
INDEX OF DRAWINGS
SHEET NO. TITLE
GENERAL
G-000B COVER SHEET
G-001B DRAWING INDEX
GI001B CODE ANALYSIS
GI002B BUILDING CODE SITE PLAN
GI100B LIFE SAFETY PLAN
STRUCTURAL
S-001B GENERAL STRUCTURAL NOTES, DESIGN LOADS & ABBREVIATIONS
S-002B GENERAL STRUCTURAL NOTES
S-101B FOUNDATION PLAN
S-501B TYPICAL CONCRETE DETAILS
ARCHITECTURAL
A-001B LEGENDS, ABBREVIATION, & GENERAL NOTES
A-002B WALL TYPES
A-101B AREA OF WORK PLAN
A-102B AIR BARRIER PLAN
AD001B GENERAL DEMOLITION NOTES
AD101B DEMOLITION PLAN
AD110B DEMOLITION REFLECTED CEILING PLAN
AD201B DEMOLITION ELEVATIONS
AE101B OVERALL FLOOR PLAN
AE110B REFLECTED CEILING PLAN
AE201B BUILDING ELEVATIONS
AE301B BUILDING SECTIONS
AE302B WALL SECTIONS
AE401B ENLARGED PLANS
AE501B DOOR AND WINDOW DETAILS
AE601B DOOR SCHEDULE
AE602B WINDOW SCHEDULE
AF001B FINISH MATERIALS LIST
AF101B FLOOR PATTERN PLAN
AF601B ROOM FINISH SCHEDULE
AI201B INTERIOR ELEVATIONS
INTERIORS
IF101B FURNITURE PLAN
IG101B SIGNAGE FLOOR PLAN
IG501B SIGN TYPES
IG601B SIGNAGE SCHEDULE
FIRE ALARM
FA001B FIRE ALARM LEGEND
FA101B FIRE ALARM PLAN
FA501B FIRE ALARM CONTROL MATRIX
FA600B FIRE ALARM / MASS NOTIFICATION RISER DIAGRAM
PLUMBING
P-001B PLUMBING LEGEND
P-101B PLUMBING PLAN
P-501B PLUMBING DETAILS
P-601B PLUMBING SCHEDULES
MECHANICAL
M-001B MECHANICAL GENERAL NOTES, ABBREVIATIONS
MD101B HVAC DEMOLITION PLAN
M-101B HVAC PLAN
M-501B HVAC DETAILS
M-601B HVAC SCHEDULES
M-700B CONTROL LEGEND & ABBREVIATIONS
M-701B CONTROLS VAV RTU
M-702B CONTROLS TERMINAL UNITS
ELECTRICAL
E-001B LEGEND, ABBREVIATIONS AND GENERAL NOTES
E-501B SCHEDULES AND DETAILS
E-601B ELECTRICAL ONE-LINE DIAGRAM
E-602B ELECTRICAL FEEDER SCHEDULE
E-603B PANEL SCHEDULES
E-604B PANEL SCHEDULES
ED101B ELECTRICAL DEMOLITION PLAN
EL101B LIGHTING PLAN
EP101B POWER PLAN
TELECOMMUNICATIONS
T-001B TELECOMMUNICATIONS LEGEND
T-101B TELECOMMUNICATION PLAN
T-501B TELECOMMUNICATION DETAILS
T-502B TELECOMMUNICATION DETAILS
T-601B TELECOMMUNICATION SYSTEM RISER DIAGRAM
TY001B SECURITY SYSTEM LEGEND
TY101B SECURITY PLAN
TY501B SECURITY SYSTEM DETAILS
BUILDING CODE ANALYSIS (IBC 2021)
BUILDING OCCUPANCY (CHAP. 3)
BUSINESS (B), FACTORY - MODERATE HAZARD (F-1), AND HIGH HAZARD GROUP 2 (H-2)
OCCUPANCY SEPARATION (SECTION 508)
OCCUPANCY SEPARATION REQUIREMENTS ARE FOR BUILDINGS WITHOUT AUTOMATIC SPRINKLER PROTECTION
THROUGHOUT.
OCCUPANCY SEPARATION:
H-2 FROM F-1 & B
F-1 FROM B
FIRE RESISTANCE RATING
REQUIRED:
3 HOUR
0 HOUR
FIRE RESISTANCE RATING
PROVIDED:
3 HOUR
0 HOUR
CONSTRUCTION TYPE (CHAP. 6)
THE EXISTING BUILDINGS, BUILDINGS B331 AND B332, ARE BOTH CONSTRUCTED OF NON-COMBUSTIBLE MATERIALS WITH NO FIRE RESISTANCE RATINGS. THE ADDITION WILL ALSO BE CONSTRUCTED OF NON-COMBUSTIBLE MATERIALS.
CONSTRUCTION TYPE PROVIDED: TYPE IIB (NON-COMBUSTIBLE, NO FIRE RESISTANCE RATING)
FIRE RESISTANCE RATING
REQUIRED:
0 HOUR
0 HOUR
0 HOUR
0 HOUR
0 HOUR
0 HOUR
0 HOUR
FIRE RESISTANCE RATING
PROVIDED:
0 HOUR
0 HOUR
0 HOUR
0 HOUR
0 HOUR
0 HOUR
0 HOUR
PER TYPE IIB CONSTRUCTION:
PRIMARY STRUCTURAL FRAME:
BEARING WALLS
EXTERIOR:
INTERIOR:
NONBEARING WALLS & PARTITIONS
EXTERIOR:
INTERIOR:
FLOOR CONSTRUCTION:
ROOF CONSTRUCTION:
PER SITE PLAN GI002 THERE IS A MINIMUM FIRE SEPARATION DISTANCE OF 30 FT AT ALL NEW EXTERIOR WALLS.
EXTERIOR WALLS DO NOT REQUIRE A FIRE RESISTANCE RATING AT THIS DISTANCE IN ACCORDANCE WITH TABLE
705.5. EXISTING EXTERIOR WALLS ON THE WEST SIDE OF BUILDING 332 HAS A FIRE SEPARATION DISTANCE OF 5 FEET.
PER IEBC 2021, SINCE THE WALL IS EXISTING AND THE OCCUPANCY IS NOT CHANGING TO A HIGHER HAZARD CATEGORY, THE EXISTING WALL FIRE RESISTANCE RATING, INCLUDING OPENINGS SHALL BE ACCEPTED.
MAXIMUM AREA OF EXTERIOR WALL
OPENINGS (TABLE 705.8):
OPENINGS ALLOWABLE:
NO LIMIT
OPENINGS PROVIDED:
30% MAXIMUM
BUILDING HEIGHT & AREA
BUILDING HEIGHT AND AREA REQUIREMENTS ARE FOR TYPE IIB CONSTRUCTION BUILDINGS WITHOUT AUTOMATIC
SPRINKLER PROTECTION THROUGHOUT.
ALLOWABLE
55 FT
SEE BELOW
PROVIDED:
22 FT
12,189 FT2
BUILDING HEIGHT (504.3):
NUMBER OF STORIES (504.4):
BUILDING AREA (506.2):
ALLOWABLE BUILDING AREA CALCULATION: THE SUM OF RATIOS OF ACTUAL AREAS AND ALLOWABLE AREA PER
OCCUPANCY MUST NOT BE MORE THAN 1 (508.4.2). TABLE VALUES
FOR NON-SPRINKLERED AREAS IN TYPE IIB CONSTRUCTIONS:
OCCUPANCY
BUSINESS (B):
FACTORY (F-1):
HIGH HAZARD (H-2):
TABLE VALUE
23,000 FT2
15,500 FT2
7,000 FT2
ALLOWABLE AREA
34,500 FT2
23,250 FT2
10,500 FT2
ACTUAL AREA
3,823 FT2
3,818 FT2
4,859 FT2
NOTE: AT LEAST 50% OF THE BUILDING PERIMETER HAS A FRONTAGE DISTANCE OF 30 FT OR GREATER. A
FRONTAGE INCREASE OF 0.5 IS APPLIED TO DETERMINE THE ALLOWABLE AREA.
(3,823 FT2 / 34,500 FT2) + (3,818 FT2 / 23,250 FT2) + (4,859 FT2 / 10,500 FT2) = 0.74 < 1
REFERENCES
INTERNATIONAL BUILDING CODE, FOR CONSTRUCTION TYPE AND BUILDING OCCUPANCY
SEPARATION, ALLOWABLE FLOOR AREA, BUILDING HEIGHT LIMITATIONS AND FIRE
SEPARATIONS DISTANCE REQUIREMENTS, EXCEPT AS MODIFIED BY UFC 3-600-01 AND UFC
4-211-01.
INTERNATIONAL EXISTING BUILDING CODE
FIRE CODE
STANDARD FOR PORTABLE FIRE EXTINGUISHERS
STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS
STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR
APPURTENANCES
NATIONAL ELECTRICAL CODE
NATIONAL FIRE ALARM AND SIGNALING CODE
STANDARD FOR FIRE DOORS AND OTHER OPENING PROTECTIVES
STANDARD FOR THE INSTALLATION OF AIR CONDITIONING AND VENTILATING SYSTEMS
LIFE SAFETY CODE, FOR SEPARATION FROM HAZARDS, BUILDING EGRESS AND LIFE SAFETY
AND APPLICABLE CRITERIA IN UFC 3-600-01
HAZARDOUS MATERIALS CODE
DOD BUILDING CODE, CHANGE 1 (SEPTEMBER 2022)
IBC 2021:
IEBC, 2021
NFPA 1, 2021
NFPA 10, 2022
NFPA 13, 2022
NFPA 24, 2022
NFPA 70, 2020
NFPA 72, 2022
NFPA 80, 2022
NFPA 90A, 2021
NFPA 101, 2021
NFPA 400, 2022
UFC 1-200-01
LIFE SAFETY ANALYSIS (NFPA 101)
BUILDING OCCUPANCY (CHAP. 3)
BUSINESS, INDUSTRIAL - GENERAL, AND INDUSTRIAL - HIGH HAZARD (PROTECTION LEVEL 2)
CONSTRUCTION TYPE (NFPA 220, CHAP. 4)
TYPE II (000)
CAPACITY OF MEANS OF EGRESS (7.3.3.1)
EGRESS COMPONENTS:
LEVEL COMPONENTS:
DOORS:
NUMBER OF MEANS OF
EGRESS (7.4.1.1):
0.2 IN. / PERSON, FOR HIGH HAZARD AREAS 0.4 IN. / PERSON
32 INCHES MIN. CLEAR WIDTH (7.2.1.2.3.2)
NOT LESS THAN TWO MEANS OF EGRESS SHALL BE PROVIDED FROM EVERY STORY
OR SECTION.
EXITS REQUIRED
EXITS PROVIDED
EXIT DISCHARGE (7.7.1): EXITS SHALL TERMINATE DIRECTLY AT A PUBLIC WAY OR AT AN EXTERIOR EXIT
DISCHARGE
TRAVEL DISTANCE
TRAVEL DISTANCE TO AN EXIT IN OCCUPANCIES WITHOUT SPRINKLER PROTECTION THROUGHOUT SHALL NOT EXCEED:
BUSINESS (38.2.6.2):
INDUSTRIAL - GENERAL
(40.2.6.1):
INDUSTRIAL HIGH HAZARD
(7.11.1, 40.2.5.1 & NFPA 400,
6.2.1.4.1 ):
ALLOWABLE
200 FT
200 FT
75 FT TO EXIT HIGH HAZARD AREA
100 FT EXIT
PROVIDED
85 FT 6 IN.
84 FT
73 FT
96 FT
DEAD-END CORRIDORS
DEAD-END CORRIDORS IN OCCUPANCIES WITHOUT SPRINKLER PROTECTION THROUGHOUT SHALL NOT EXCEED:
BUSINESS (38.2.5.3.2):
INDUSTRIAL - GENERAL
(40.2.5.1):
INDUSTRIAL HIGH HAZARD
(40.2.5.1):
ALLOWABLE
20 FT
50 FT
NOT
PERMITTED
PROVIDED
0 FT
0 FT
0 FT
COMMON PATH OF TRAVEL
COMMON PATH OF TRAVEL IN OCCUPANCIES WITHOUT SPRINKLER PROTECTION THROUGHOUT SHALL NOT EXCEED:
BUSINESS (38.2.5.2.3):
INDUSTRIAL - GENERAL
(40.2.5.1):
INDUSTRIAL HIGH HAZARD
(40.2.5.1):
ALLOWABLE
75 FT
50 FT
NOT
PERMITTED1
PROVIDED
31 FT
26 FT
0 FT
NOTE: HIGH HAZARD AREAS ARE REQUIRED TO BE PROTECTED WITH AUTOMATIC SPRINKLERS.
NOTE: HIGH HAZARD AREAS ARE REQUIRED TO BE PROTECTED WITH AUTOMATIC SPRINKLERS.
NOTE: HIGH HAZARD AREAS ARE REQUIRED TO BE PROTECTED WITH AUTOMATIC SPRINKLERS.
1. A SINGLE MEANS OF EGRESS IS PERMITTED IN A HAZARDOUS AREA IF THE AREA DOES NOT EXCEED 200 FT2, CALCULATED OCCUPANT LOAD DOES NOT EXCEED 3 PERSONS AND THE COMMON PATH DOES NOT EXCEED 25
FT. (7.11.4)
OCCUPANT LOAD FACTOR (7.3.1.2)
USE
BUSINESS
ASSEMBLY, LESS CONCENTRATED
INDUSTRIAL, GENERAL
MECHANICAL, ELECTRICAL & BUILDING EQUIPMENT
SPACES (UFC 3-600-01, TABLE 10-1)
IT/COMM EQUIPMENT (UFC 3-600-01, TABLE 10-1)
LOAD FACTOR (FT2 / PERSON)
150 GROSS
15 NET
100 GROSS
500 GROSS
300 GROSS
INTERIOR FINISHES
FIRE PROTECTION ENGINEERING FOR FACILITIES, 8 AUGUST 2016, CHANGE 6 (MAY 2021)
DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS, 12 DECEMBER 2018, CHANGE 2
(JULY 2022)
DESIGN AND O&M: MASS NOTIFICATION SYSTEMS, 9 APRIL 2008, CHANGE 1 (JANUARY 2010)
UFC 3-600-01
UFC 4-010-01
UFC 4-021-01
REFERENCES CONTINUED
FIRE DOORS: THE MINIMUM FIRE RATING OF OPENING PROTECTIVES IN FIRE BARRIERS, FIRE RATED
SMOKE BARRIERS AND FIRE RATED SMOKE PARTITIONS SHALL BE IN ACCORDANCE
WITH NFPA 101 TABLE 8.3.3.2.2
ALLOWABLE
3 HOUR
PROVIDED
3 HOUR
COMPONENT
3 HOUR FIRE BARRIER
-DOOR
FIRE SEPARATIONS
SPECIAL HAZARDS (8.7): AREAS HAVING A DEGREE OF HAZARD GREATER THAN THAT NORMAL TO THE GENERAL
OCCUPANCY OF THE BUILDING SHALL BE SEPARATED FROM OTHER PARTS OF THE
BUILDING WITH A FIRE BARRIER HAVING A RESISTANCE RATING NOT LESS THAN 1
HOUR AND WITHOUT WINDOWS.
CORRIDORS: EXIT ACCESS CORRIDORS DO NOT REQUIRE 1 HOUR FIRE RESISTANCE RATING PER
NFPA 101 38.3.6.1 AND 40.3.6.
USE
OTHER SPACES
ALLOWABLE
A, B OR C
PROVIDED
A
HIGH HAZARD PROTECTION LEVEL 2 REQUIREMENTS
CHAPTER 4 OF UFC 3-600-01 SUPERCEDES IBC CHAPTER 4 IN ITS ENTIRETY. FOR UNIQUE HAZARDS NOT ADDRESS
WITHIN CHAPTER 4 OF UFC 3-600-01, COMPLY WITH NFPA 101.
HAZARDOUS MATERIALS USED AND STORED IN THE BUILDING INCLUDE COMBUSTIBLE AND WATER REACTIVE
METALS.
HIGH HAZARD AREA SHALL BE SEPARATED FROM OTHER PARTS OF THE BUILDING WITH NOT LESS THAN 2 HOUR FIRE SEPARATION AND HAVE EXPLOSION VENTING THROUGH AN EXTERIOR WALL PER UFC 3-600-01, 4-2.2. ALSO, REFER TO
THE DEFLAGRATION VENTING SECTION BELOW.
AUTOMATIC SPRINKLERS SHALL BE PROVIDED WITH INDICATING VALVE TO ISOLATE SPRINKLER SYSTEM WITHIN
HAZARDOUS AREA PER UFC 3-600-01, 4-20.2.4.
FIRE EXTINGUISHER REQUIREMENTS
ORDINARY HAZARD
2-A, 10-B, C
1500 FT2
11,250 FT2
30 FT WITH 10-B,
50 FT WITH 20-B
EXTRA HAZARD
4-A, 40-B, C
1000 FT2
11,250 FT2
30 FT WITH 40-B,
50 FT WITH 80-B,
75 FT FOR TYPE D
EXTINGUISHERS
LIGHT HAZARD
2-A, C
3000 FT2
11,250 FT2
75 FT
DRY CHEMICAL TYPE ABC FIRE EXTINGUISHERS SHALL BE PROVIDED THROUGHOUT THE BUILDING. ADDITIONALLY, TYPE D FIRE EXTINGUISHERS WILL BE PROVIDED IN THE HIGH HAZARD OCCUPANCY AREA.
FIRE EXTINGUISHERS MUST BE PROVIDED TO MEET THE CRITERIA OF NFPA 10 FOR THE RESPECTIVE OCCUPANCY HAZARDS. THE ADMINISTRATIVE WING IS CLASSIFIED AS LIGHT HAZARD AND POTENTIAL FIRES ARE EXPECTED TO BE TYPE A OR C. THE HIGH HAZARD AREA IS CLASSIFIED AS EXTRA HAZARD AND POTENTIAL FIRES ARE EXPECTED TO BE TYPE A, B, C, OR D. THE MACHINE SHOP WING IS CLASSIFIED AS ORDINARY HAZARD AND POTENTIAL FIRES ARE
EXPECTED TO BE TYPE A, B, OR C.
COMPONENT
MINIMUM RATING
MAXIMUM FLOOR AREA PER
UNIT OF A
MAXIMUM FLOOR AREA PER
EXTINGUISHER
MAXIMUM TRAVEL DISTANCE
TO EXTINGUISHER
DEFLAGRATION VENTING
UFC 3-600-01, 4-2.2, EXPLOSION VENTING IS REQUIRED ON AN EXTERIOR WALL. A DUST HAZARD ANALYSIS DETERMINED THAT THE MAXIMUM KST = 27 (BAR*M / S) AND THE MAXIMUM PMAX = 6.1 BAR-G. THE YIELD STRENGTH OF
THE STRUCTURE IS 33 KSI (2,275 BAR).
PER NFPA 68, THE REDUCED PRESSURE FROM VENTING SHALL NOT EXCEED 2/3 THE YIELD STRENGTH OF THE ENCLOSURE OR THE YIELD STRENGTH INCLUDING A DYNAMIC LOAD FACTOR (DLF). WITH A WORSE CASE DLF OF 1.5, THE MAXIMUM ALLOWABLE REDUCED PRESSURE IS 1,516 BAR. 1,516 BAR EXCEEDS THE 6.1 BAR THE HAZARDOUS
MATERIAL IS CAPABLE OF PRODUCING. THUS DEFLAGRATION VENTING IS NOT REQUIRED.
SHEET ID
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R
IN
G C
E N
T E
R
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
D R
E M
Y
A u to d e s k D o c s /0
-0
-J
B M
D L B
B
/J
B M
D L
L a b E x p a n s io n A
.r v t
/1
/2
:0
:0
P
M
GI001B
C O
D E
A N
A L Y
S
IS
J O
IN
T
B A
S E
M C
G U
IR
E
-D
IX
-L A
K E
H U
R S
T L A
K E
H U
R S
T N
J R
Y
E S
T E
R
C S
P E
N C
E R
J A
N U
A R
Y
M S
B L
-4
F
IN
A L
S U
B M
IT
T
A L
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
B R
E N
O V
A T
IO
ADDITIVE LAB101
ADDITIVE LAB
(PARTICULATE
CONTAINMENT)102
OPTOMEC
CONTAINMENT103
MECH
ELECT
COMM
POWDERHANDLING
W V
W V
W V
B U
IL
D
IN
G
B U
IL
D
IN
G
T
B U
IL
D
IN
G
B U
IL
D
IN
G
T E
N T
T E
N T
H U
T
B U
IL
D
IN
G
CONCRETE
CONCRETE
C O
N C
R E
T E
C O
N C
R E
T E
S
LA
B
C O
N C
R E
T E
S
LA
B
CONCRETE
CONCRETE
M E
T A
L P
L A
T F O
R M
G A
T E
GATE
C O
N C
R E
T E
P A
T H
E L E
C T R
IC
C
O N
C R
E T E
P A
D
C O
N C
R E
T E
R A
M P
STORAGE
CONTAINER
STORAGE
CONTAINER
STORAGE
CONTAINER
STORAGE
CONTAINER
STORAGE
CONTAINER
SHIPPING
CONTAINER
S H
IP
P
IN
G
C O
N T A
IN
E
R
S H
IP
P
IN
G
C O
N T A
IN
E
R
S H
IP
P
IN
G
C O
N T A
IN
E
R
S H
IP
P
IN
G C
O N
T A
IN
E R
SHIPPING
CONTAINER
S H
IP
P
IN
G
C O
N T A
IN
E
R
S H
IP
P
IN
G
C O
N T A
IN
E
R
S H
IP
P
IN
G
C O
N T A
IN
E
R
S H
IP
P
IN
G
C O
N T A
IN
E
R
P A
V E
D P
A R
K
IN
G L
O T
S H
E L V
E S
PLANTER
W O
O D
E N
R A
M P
S T A
IR
C
A S
E
TRENCH DRAIN
C
O N
C R
E T E
B A
R R
IE
R
S
C O
N C
R E
T E
B A
R R
IE
R
S
P A
V E
M E
N T
P A
V E
M E
N T
P A
V E
M E
N T
HOUGHTON ROAD
A C
U N
IT
O
N R
A
IS
E D
C O
N C
R E
T E
A C
U N
IT
S
A C
U N
IT
O
N R
A
IS
E D
C O
N C
R E
T E
A C
U N
IT
A C
U N
IT
A C
U N
IT
A C
U N
IT
V E
N T S
VENTS
S T O
N E
S
S T O
N E
S
V A
U L T
F
IR
E D
E P
A R
TM
E
N T
C O
N N
E C
T
IO
N
E Q
U
IP
M E
N T
E Q
U
IP
M E
N T
E Q
U
IP
M E
N T
R O
O F T
U R
B
IN
E S
F
IR
E P
H O
N E
F
IR
E P
H O
N E
F
IR
E P
H O
N E
F
IR
E P
H O
N E
R A
IL
A B
A N
D O
N E
D E
X P
O S
E D
R A
IL
R
O A
D
T R
A C
K S
C O
V E
R E
D W
IT
H
A S
P H
A L T
G E
N E
R A
T O
R
F
IR
E E
X T
IN
G U
IS
H
E R
C O
M P
R E
S S
E D
A
IR
P
IP
E
P
IP
E
F
IR
E P
H O
N E
F
IR
E P
H O
N E
S T
R I P
E
S T
R I P
E
S T
R I P
E
R A
IL
S
E D
G E
P A
V E
P A
V E
C O
M P
E N
S A
T E
D
A
IR
D
IS
C H
A R
G E
H O
IS
T
P
IV
P
IV
S T E
E L P
L A
T E
(R E
M O
V A
B L E
C O
V E
R E
D
C O
N N
E C
T
IO
N
VENT
VENT
R
O O
F D
R A
IN
C O
N C
R E
T E
W
M
IS
C E
Q U
IP
M
E N
T
R O
O F D
R A
IN
R O
O F D
R A
IN
R O
O F D
R A
IN
R O
O F D
R A
IN
H
IG
H V
O L T A
G E
E L E
C T R
IC
E
Q U
IP
M
E N
T
R O
O F D
R A
IN
R O
O F D
R A
IN
R O
O F D
R A
IN
R O
O F D
R A
IN
P
IN
E R
O W
P
IN
E R
O W
A C
U N
IT
CLENDENING STREET
R O
O F D
R A
IN
R O
O F D
R A
IN
R O
O F D
R A
IN
S H
IP
P
IN
G
C O
N T A
IN
E
R
S H
IP
P
IN
G
C O
N T A
IN
E
R
R O
O F D
R A
IN
PLANTER
S E
V E
R Y
N S
R O
A D
G
T
41'-6"
'-6
FIRE WATER MAIN
PIV
FIRE HYDRANT
FIRE HYDRANT
'-6
26'-0"
5'-0"
'-6
FIRE DEPARTMENT
CONNECTION
199 LINEAR FEET
335 LINEAR FEET
143 LINEAR FEET
TO THE FDC
SHEET ID
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R
IN
G C
E N
T E
R
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
D R
E M
Y
A u to d e s k D o c s /0
-0
-J
B M
D L B
B
/J
B M
D L
L a b E x p a n s io n A
.r v t
/1
/2
:0
:0
P
M
GI002B
B U
IL
D
IN
G
C O
D E
S
IT
E P
L A
N
J O
IN
T
B A
S E
M C
G U
IR
E
-D
IX
-L A
K E
H U
R S
T L A
K E
H U
R S
T N
J R
Y
E S
T E
R
C S
P E
N C
E R
J A
N U
A R
Y
M S
B L
-4
F
IN
A L
S U
B M
IT
T
A L
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
B R
E N
O V
A T
IO
N
1" = 30'-0" A1
BUILDING CODE SITE PLAN
PLAN NORTH
30 15 0 30 60
GENERAL NOTES
1. FIRE SEPARATION DISTANCES ARE SHOWN ON THE BUILDING
CODE SITE PLAN. THERE IS A MININIMUM FIRE SEPARATION
DISTANCE OF 30 FT FROM ALL NEW EXTERIOR WALLS.
EXTERIOR WALLS DO NOT REQUIRE A FIRE RESISTANCE RATING
AT THIS DISTANCE IN ACCORDANCE WITH IBC TABLE 705.5.
EXISTING EXTERIOR WALL ON THE WEST SIDE OF THE BUILDING
HAS A FIRE SEPARATION DISTANCE OF 5 FT. PER IEBC 2021,
SINCE THE WALL IS EXISTING AND THE OCCUPANCY IS NOT
CHANGING TO A HIGHER HAZARD CATEGORY, THE EXISTING
WALL FIRE RESISTANCE RATING, INCLUDING OPENINGS SHALL
BE ACCEPTED.
2. EMERGENCY VEHICLE (FIRE DEPARTMENT) ACCESS IS VIA
EXISTING ADJACENT ROADS AND EXISTING PARKING AREAS.
3. THIS FACILITY IS WITHIN A SECURED FACILITY, ANTITERRORISM
SECURE ACCESS REQUIREMENTS DO NOT APPLY.
4. ACCESS TO THE BUILDING INTERIOR IS WITHIN 50 FT FROM FIRE
DEPARTMENT ACCESS ROOM. EXTERIOR ACCESS TO THE FIRE
SPRINKLER RISER ROOM IS LOCATED ON THE SOUTH SIDE OF
THE BUILDING.
5. THE BUILDING FDC IS LOCATED ON THE SOUTHSIDE OF THE
BUILDING AND IS WITHIN 150 FT OF A FIRE HYDRANT. FINAL FDC
LOCATION TO BE APPROVED BY BASE FIRE DEPARTMENT.
6. FIRE HYDRANTS, PIV'S AND NEW AND EXISTING FIRE WATER
LINES ARE SHOWN ON THE BUILDING CODE SITE PLAN.
7. A FIRE PUMP IS NOT REQUIRED OR PROVIDED.
8. A WATER STORAGE TANK IS NOT REQUIRED OR PROVIDED.
9. THERE ARE NO HAZADOUS SPILL CONTAINMENT
REQUIREMENTS FOR THIS FACILITY.
10. THE FIRE SUPPRESSION SYSTEM BACKFLOW PREVENT IS
LOCATED IN THE MECH/EQUIP. ROOM AND IS ACCESSIBLE FROM
THE BUILDING EXTERIOR.
S S S S
1-HR RATED FIRE BARRIER
2-HR RATED FIRE BARRIER
3-HR RATED FIRE BARRIER
SMOKE PARTITION
EXIT PATH
COMMON PATH OF TRAVEL
COMMON PATH OF TRAVEL
TOTAL TRAVEL DISTANCE
DOOR EGRESS TAGS:
NUMBER OF OCCUPANTS USING EXIT
EGRESS MAXIMUM CAPACITY
CLEAR WIDTH PROVIDED
COMPONENT MINIMUM WIDTH REQUIRED
CALCULATED OCCUPANT LOAD
USE GROUP AREA
OCCUPANCY USE GROUP
OCCUPANT LOAD FACTOR
BUILDING OCCUPANCY CLASSIFICATION
USE GROUP AND FUNCTION OF SPACE TAG:
LIFE SAFETY LEGEND
000 SF
IND.
F-1
150 GSF
130' 55'
EMERGENCY KEY BOX
32"
34"
KB
FIRE EXTINGUISHER - TYPE ABC
FIRE EXTINGUISHER - TYPE D
ILLUMINATED EXIT SIGN - SINGLE FACE
(ARROWS INDICATE EXIT DIRECTION)
ILLUMINATED EXIT SIGN - DOUBLE FACE
(ARROWS INDICATE EXIT DIRECTION)
1 4
G
F
E
D
C
B
A
3,724 SF
IND.
F-1
100 GSF
32"
33"
32"
33"
16532"
33"
32"
33"
84'-0" 26'-0"
2,305 SF
IND.
H-2
100 GSF
442 SF
EQUIP.
H-2
500 GSF
66'-0" 0'-0"
EQUIP.
IND.
1,994 SF
IND.
H-2
100 GSF
67'-0" 0'-0"
K B
45'-0" 0'-0"
71'-0" 0'-0"
48'-0" 0'-0"
61'-0" 26'-0"
10'-0"
3 HOUR FIRE RATED
COLUMN
32"
33"
NOT IN SCOPE
NOT IN SCOPE
NOT IN SCOPE
NOT IN SCOPE
56'-0" 0'-0"
63'-6" 0'-0"
32"
52"
MACHINE
SHOP
COMPRESSOR
RESTROOM
SHEET ID
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R
IN
G C
E N
T E
R
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
D R
E M
Y
A u to d e s k D o c s /0
-0
-J
B M
D L B
B
/J
B M
D L
L a b E x p a n s io n A
.r v t
/1
/2
:0
:0
P
M
GI100B
L
IF
E S
A F
E T
Y P
L A
N
J O
IN
T
B A
S E
M C
G U
IR
E
-D
IX
-L A
K E
H U
R S
T L A
K E
H U
R S
T N
J R
Y
E S
T E
R
C S
P E
N C
E R
J A
N U
A R
Y
M S
B L
-4
F
IN
A L
S U
B M
IT
T
A L
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
B R
E N
O V
A T
IO
N
GENERAL NOTESOCCUPANCY USE LEGEND
MECH/ELECT. EQUIPMENT (UFC 3-600-01)
GENERAL INDUSTRIAL (NFPA 101)
1. IN HIGH HAZARD AREA TRAVEL PATHS ARE BROKEN INTO
TWO. FIRST SEGMENT IS SHOWING TRAVEL DISTANCE OUT
OF HIGH HAZARD AREA. SECOND SEGMENT IS SHOWING
REMAINING DISTANCE TO AN EXIT.
NAME AREA
BLDG.
OCCUPANCY
USE
GROUP
LOAD FACTOR
(SQFT/OCC.)
OCCUPANT
LOAD
ADD. MANF. 1994 SF H-2 IND. 100 20
BREAK 206 SF B LS
CONC.
15 14
BUSINESS 3518 SF B B 150 24
CLEAN
ROOM
2305 SF H-2 IND. 100 23
EQUIPMENT 442 SF H-2 EQUIP. 500 1
SHOP 3724 SF F-1 IND. 100 38
TOTALS: 12189 SF 120
OCCUPANT LOAD - BUILDING TOTAL
1/8" = 1'-0" A1
LIFE SAFETY PLAN
PLAN NORTH
0' 2' 4' 8' 16'
OCCUPANT LOAD - PROJECT 2
NAME AREA
BLDG.
OCCUPANCY
USE
GROUP
LOAD FACTOR
(SQFT/OCC.)
OCCUPANT
LOAD
SHOP 3724 SF F-1 IND. 100 38
TOTALS: 3724 SF 38
GRAVITY LOADS IN ACCORDANCE WITH UFC 3-301-01, STRUCTURAL LOAD DATA.
1 OCTOBER 2019, UFC 4-010-01, DoD MINIMUM ANTITERRORISM STANDARDS FOR
LOCATION
OTHER LIVE LOADS NOT SHOWN SHALL BE IN ACCORDANCE WITH ASCE 7-16, MINIMUM
DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES. MINIMUM DESIGN ROOF
DEAD LOAD EQUALS 25 PSF. SNOW LOADS IN ACCORDANCE WITH UFC 3-310-01,
LATERAL LOADS:
WIND LOADS:
IN ACCORDANCE WITH UFC 3-310-01, STRUCTURAL LOAD DATA AND ASCE 7-16,
MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES.
BASIC WIND SPEED
WIND IMPORTANCE FACTOR
WIND EXPOSURE CATEGORY
SEISMIC CRITERIA FOR EXISTING STRUCTURE:
DETERMINED IN ACCORDANCE WITH UFC 1-200-01 AND IBC 2021, BY INCORPORATING
THE FOLLOWING PARAMETERS:
OCCUPANCY CATEGORY
SITE CLASSIFICATION
SHORT PERIOD SPECTRAL ACCELERATION
ONE SECOND SPECTRAL ACCELERATION
SEISMIC DESIGN CATEGORY
SEISMIC IMPORTANCE FACTOR
BUILDING, 12 DECEMBER 2018 WITH CHANGE 1, 19 AUGUST 2020, ASCE 7-16,
UNIFORM CONCENTRATED
LIVE LOAD LIVE LOAD
ROOF 20 PSF (MIN.) OR CONTROLLING SNOW LOAD
NEW FLOORS 250 PSF 2000 LB
PARTITION LOADS 20 PSF
MECH/ELEC ROOM 150 PSF 2000 LB
MULTIPURPOSE ROOMS 50 PSF 2000 LB
PUBLIC AREAS AND CORRIDORS 100 PSF 2000 LB
RESTROOMS 75 PSF 2000 LB
LIGHT STORAGE 125 PSF
ALL OTHER AREAS 80 PSF 2000 LB
MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, IEBC 2021,
DEAD LOAD
FLAT ROOF (B331/B332 NEW ROOFS)
NEW PITCHED ROOF
24 PSF
20 PSF
OTHER STRUCTURES.
GROUND SNOW LOAD
ROOF SLOPE FACTOR
SNOW THERMAL FACTOR
SNOW IMPORTANCE FACTOR
ROOF EXPOSURE FACTOR
FLAT ROOF SNOW LOAD
SLOPED ROOF SNOW LOAD
Pg
Cs
Ct
I
Ce
Pf
Ps
20 PSF
1.0
1.0
1.0
.9
13 PSF
13 PSF
p = 0.00256*Kz*Kzt*Kd*V^2*I
119 MPH
1.0 (CATEGORY II)
V
I
C
II
D (ASSUMED)
Ss
S1
B
1.0
0.194g
0.048g
AND IBC 2021:
STRUCTURAL LOAD DATA AND ASCE 7-16, MINIMUM DESIGN LOADS FOR BUILDINGS AND
ROOF SNOW LOAD W/ RAIN ON SNOW SURCHARGE Ps = 18 PSF
*SNOW DRIFT LOADS WILL ALSO APPLY
ABV
ADDL
HT
HSH
HSB
HORIZ
HGR
HDR
HD
(H)
GR
GLB
GALV
GA
FTG
FS
FRMG
FOS
FOM
FOC
FN
FLR
FLG
FJ
FF
FDN
EW
ES
EQ
EN
EMBED
ELEV
ELEC
EL
EF
EA
(E)
DWL
DWG
DP
DO
DN
DIM
DIA
DF
DBL
CTRD
CSK
CP
CONT
CONST
CONN
CONC
COL
CLR
CL
CJ
CJ
CIP
CB
C
BTWN
BRG
BP
BOS
BOF
BN
BM
BLW
BLKG
BLK
(B)
AWS
ASSOCIATION
AWPA
TESTING AND MATERIALS
ASTM
ASD
ARCH
ASSOCIATION
APA
ALT
STEEL CONSTRUCTION
AISC
ADJ
WWF
WT
WPJ
WP
WD
W/O
W/
WL
VSH
VERT
(V)
UON
UNO
UBC
TYP
TS
TOW
TOT
TOS
TOP
TOC
TO
TN
THRD
THK
TG
T AND B
(T)
STRUC
STL
STIFF
STGR
STD
SQ
SPEC
SOG
SIM
SHTHG
SEP
SECT
SCHED
SC
RF
REF
REQD
REINF
R
P.T.
PP
PLYWD
PLCS
PL
PC
ORIG
OPP
OPNG
OH
OF
OC
NTS
NS
NO
NIC
MTL
MISC
MIN
MFR
MECH
MB
MAX
MATL
LT WT
LOC
LDGR
KP
JT
JST
IF
AB ANCHOR BOLT ICC INTERNATIONAL CODE
COUNCILABOVE
ADDITIONAL
INSIDE FACEADJACENT
JOISTAMERICAN INSTITUTE OF
JOINT
KING POSTALTERNATE
LEDGER
AMERICAN PLYWOOD
LOCATION
LIGHTWEIGHT
ARCHITECTURAL/ARCHITECT
MATERIAL
MAXIMUM
ALLOWABLE STRESS DESIGN
AMERICAN SOCIETY FOR
MACHINE BOLT
MECHANICAL
AMERICAN WOOD PRESERVERS
MANUFACTURER
MINIMUM
MISCELLANEOUS
AMERICAN WELDING SOCIETY
BOTTOM
METAL
BLOCK
NOT IN CONTRACT
BLOCKING
NUMBER
BELOW
NEAR SIDE
BEAM
NOT TO SCALE
BOUNDARY NAIL
ON CENTER
BOTTOM OF FOOTING
OUTSIDE FACE
BOTTOM OF STEEL
OPPOSITE HAND
BASE PLATE
OPENING
BEARING
OPPOSITE
BETWEEN
ORIGINAL
CAMBER
PRECAST
CARRIAGE BOLTS
PLATECAST-IN-PLACE
PLACESCONSTRUCTION JOINT
PLYWOODCEILING JOIST
PARTIAL PENETRATIONCENTER LINE
POST-TENSIONCLEAR
RADIUSCOLUMN
REINFORCEMENTCONCRETE
REQUIREDCONNECTION
REFERENCECONSTRUCTION
ROOFCONTINUOUS
SHEAR CONNECTORCOMPLETE PENETRATION
SCHEDULECOUNTER SINK
SECTION
CENTERED
SEPARATION
DOUBLE
SHEATHING
DOUGLAS FIR/LARCH
SIMILAR
DIAMETER
SLAB ON GRADE
DEEP
SPECIFICATION
DIMENSION
SQUARE
DOWN
STANDARD
DITTO (REPEAT)
STAGGER
DRAWING
STIFFENERS
DOWEL
STEEL
EXISTING
STRUCTURAL
EACH
TOP
EACH FACE
TOP AND BOTTOMELEVATION
TAPERED GIRDERELECTRICAL
THICKNESS/THICKELEVATOR
THREADEDEMBEDMENT
TOENAILEDGE NAIL
TOP OFEQUAL OR EQUIVALENT
TOP OF CONCRETEEACH SIDE
TOP OF PARAPETEACH WAY
TOP OF STEELFOUNDATION
TOTALFINISHED FLOOR
TOP OF WALLFLOOR JOIST
TUBE STRUCTURALFLANGE
TYPICALFLOOR
UNIFORM BUILDING CODEFIELD NAIL
UNLESS NOTED OTHERWISEFACE OF CONCRETE
UNLESS OTHERWISE NOTEDFACE OF MASONRY
VERTICALFACE OF STUD
VERTICALFRAMING
VERTICAL SLOTTED HOLESFAR SIDE
WIND LOADFOOTING
WITH
GAUGE WITHOUT
GALVANIZED WOOD
GLUED LAMINATED BEAM WATER PROOF/WORK POINT
GRADE
WEAKENED PLANE JOINT
HORIZONTAL
WEIGHT
HOLDOWN
WELDED WIRE FABRIC
HEADER
HEIGHT
HORIZONTALLY SLOTTED HOLES
HIGH STRENGTH BOLT
HORIZONTAL
HANGER
CGS CENTER OF GRAVITY OF STEEL
GSN GENERAL STRUCTURAL NOTES
5/- INDICATES A SECTION OR DETAIL
THAT APPEARS ON THE SAME SHEET
AS THE REFERING INFORMATION.
EF EDGE FASTENER
FY YIELD STRENGTH
SCJ SHRINKAGE CONTROL JOINT
I.E. INSIDE FACE
L.G. LIGHT GAUGE
STRUCTURAL PLANS INDICATE ONLY THE APPROXIMATE LOCATION OF MECHANICAL,
ELECTRICAL AND OTHER EQUIPMENT, AS WELL AS THE RELATED AUXILIARY FRAMING
NECESSARY TO SUPPORT SUCH EQUIPMENT. THE FINAL POSITIONING OF THESE
ITEMS IS DEPENDENT UPON THE EQUIPMENT PROVIDED. THE CONTRACTOR SHALL BE
IN THIS REGARD, AND PROVIDING NECESSARY DIMENSIONS IN A TIMELY MANNER TO
ALL PARTIES INVOLVED. THE CONTRACTOR SHALL PROVIDE TEMPORARY BRACING AS
ROOF AND FLOOR MEMBERS. BRACING MUST BE FULLY EFFECTIVE UNTIL ROOF AND
FLOOR DEAD LOADS ARE IN PLACE.
CONCRETE GRADE WALLS SHALL BE TEMPORARILY BRACED IF BACKFILL IS ONLY ON
ONE SIDE OR THEY SHALL BE BACK FILLED ON BOTH SIDES SIMULTANEOUSLY, WHERE
REQUIRED, TO PREVENT DEFLECTION, CRACKING OR FAILURE OF CONCRETE GRADE
EXPANSION ANCHORS CAN ONLY BE USED FOR FIELD REPAIRS AND REQUIRE
APPROVAL OF THE CONTRACTING OFFICER. REFER TO "POST INSTALLED CONCRETE
14.
15.
RESPONSIBLE FOR COORDINATING WORK BETWEEN SUBCONTRACTORS AND CRAFTS
REQUIRED DURING THE ERECTION OF THE STRUCTURAL FRAME.
16.
17.
ANCHORS" SECTION OF GENERAL NOTES FOR ADDITIONAL INFORMATION.
CONSTRUCTION METHODS AND PROJECT SAFETY: THE CONTRACT DRAWINGS AND
SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE AND DO NOT INDICATE
METHODS, PROCEDURES OR SEQUENCE OF CONSTRUCTION. THE CONTRACTOR
SHALL TAKE NECESSARY PRECAUTIONS TO MAINTAIN AND INSURE THE INTEGRITY OF
CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING AND BRACING,
AND BE SOLELY RESPONSIBLE FOR CONFORMING TO ALL APPLICABLE LOCAL, STATE
ANY DEVIATION FROM THE APPROVED SET OF STRUCTURAL DRAWINGS SHALL ONLY
BE MADE AFTER WRITTEN APPROVAL BY THE CONTRACTING OFFICER.
12.
13.
THE STRUCTURE DURING CONSTRUCTION. THE CONTRACTOR SHALL DESIGN,
AND FEDERAL SAFETY AND HEALTH STANDARDS, LAWS AND REGULATIONS; OSHA
WALLS.
VERIFICATION: VERIFY ALL DIMENSIONS, ELEVATIONS AND SITE CONDITIONS BEFORE
STARTING WORK. NOTIFY THE CONTRACTING OFFICER IMMEDIATELY OF ANY
CONFLICTS: NOTES AND DETAILS ON THE DRAWINGS TAKE PRECEDENCE OVER THE
CODES: ALL MATERIALS AND WORK SHALL CONFORM TO THE REQUIREMENTS OF THE
LATEST CODES, UFCS AND ASCE 7.
SUBSTITUTIONS: PROVIDE MANUFACTURER'S ICC REPORTS AND A LIST OF ALL
PROPOSED SUBSTITUTIONS TO THE CONTRACTING OFFICER FOR REVIEW BEFORE
SIMILAR WORK: WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY
PART OF THE WORK, SUCH DETAILS SHALL BE THE SAME AS FOR SIMILAR WORK
PIPES, DUCTS, SLEEVES, CHASES, ETC.: SHALL NOT BE PLACED IN SLABS, BEAMS, OR
WALLS UNLESS SPECIFICALLY SHOWN OR NOTED NOR SHALL ANY STRUCTURAL
MEMBER BE CUT FOR PIPES, DUCTS ETC., UNLESS SPECIFICALLY SHOWN. OBTAIN
PRIOR WRITTEN APPROVAL FROM THE CONTRACTING OFFICER FOR INSTALLATION OF
EXCAVATIONS: LOCATE AND PROTECT UNDERGROUND OR CONCEALED CONDUIT,
PLUMBING OR OTHER UTILITIES WHERE NEW WORK IS BEING PERFORMED.
CONSTRUCTION LOADS: MATERIALS SHALL BE EVENLY DISTRIBUTED IF PLACED ON
FRAMED FLOORS OR ROOFS. LOADS SHALL NOT EXCEED THE ALLOWABLE LOADING
FOR THE SUPPORTING MEMBERS AND THEIR CONNECTIONS.
THE STRUCTURAL DRAWINGS ILLUSTRATE THE NEW STRUCTURAL MEMBERS, REFER
TO ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR NON-STRUCTURAL
ITEMS WHICH REQUIRE SPECIAL PROVISIONS DURING THE CONSTRUCTION OF
REFER TO ARCHITECTURAL PLANS FOR FLOOR DEPRESSIONS, SLOPES, DRAINS,
CURBS, PADS, EMBEDDED ITEMS, NON-BEARING PARTITIONS, ETC.
REFER TO MECHANICAL AND ELECTRICAL PLANS FOR SLEEVE AND HANGERS FOR
PIPES, DUCTS AND EQUIPMENT.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
SHOWN ON DRAWINGS.
STRUCTURAL MEMBERS.
DISCREPANCIES.
GENERAL NOTES AND TYPICAL DETAILS IN CASE OF CONFLICT.
ANY ADDITIONAL PIPES, DUCTS, ETC.
FABRICATION.
REQUIREMENTS; AND EM385-1-1.
SHEET ID
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R
IN
G C
E N
T E
R
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
R
B R
E N
O V
A T
IO
N
A u to d e s k D o c s /0
-0
-J
B M
D L B
B
/0
-0
-J
B M
D L -B
B
L a b E x p a n s io n S
.r v t
/1
/2
:4
:2
A
M
S-001B
G E
N E
R A
L S
T R
U C
T U
R A
L N
O T
E S
D
E S
IG
N
L O
A D
S
A B
B R
E V
IA
T
IO
N
S
J B
M D
L L a k e h u rs t, N
J A
M
A G
IN
N
IS
A M
A G
IN
N
IS
C T
R A
N
J A
N U
A R
Y
F A
D
F
IN
A L
S U
B M
IT
T
A L
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
-0
D C
A V
IN
GENERAL REQUIREMENTS DESIGN ANALYSIS ABBREVIATIONS
BLOCK LAYUP: RUNNING BOND, CONCAVE COMPRESSED JOINTS, USE OPEN END UNITS
REINFORCEMENT:
2.
3.
REINFORCED HOLLOW UNIT MASONRY (SPECIAL INSPECTION REQUIRED).
MATERIALS:1. (F'm = 1500 PSI)
CONCRETE BLOCK ASTM C 90 TYPE 1, LOAD BEARING 1900
PSI BLOCK WITH BOND BEAM UNITS AT
HORIZONTAL REINFORCING, DRY UNITS, YARD
CURE 28 DAYS.
MORTAR ASTM C270, ASTM C 780, TYPE S
(DO NOT USE MASONRY CEMENT).
GROUT ASTM C 476, ASTM C 1019, USE 2000 PSI
MIN AT 28 DAYS OR EQUIVALENT TO BLOCK
STRENGTH WHICHEVER IS GREATER WITH SIKA
GROUTED OR EQUAL, 8-10 INCH SLUMP
REINFORCEMENT ASTM A-615, GRADE 60 TYPICAL
ANCHOR BOLTS ASTM A-307, HEADED MACHINE BOLTS
EXPANSION ANCHORS ICC ES APPROVED FOR GROUT FILLED CONCRETE
MASONRY.
AT STACKED BOND PATTERN.
A) VERTICAL: ONE PIECE, NO SPLICES, CENTERED IN THE WALL UNLESS
SPECIFICALLY DETAILED OTHERWISE. VERTICAL SUPPORT SPACERS AT 200
REINFORCEMENT DIAMETERS MAXIMUM. DOWEL REINFORCEMENT TO SUPPORT
MEMBERS WITH SAME SIZE AND SPACING OF REINFORCEMENT AS SHOWN ON THE
DRAWINGS. THECONTRACTOR HAS THE OPTION TO USE ADDITIONAL LAP SPLICES
FOR THE PLACEMENT OF THE VERTICAL REINFORCING. IT IS THE CONTRACTORS
RESPONSIBILITY TO PROVIDE SHOP DRAWINGS FOR REVIEW SHOWING LOCATION
OF ALL REINFORCING STEEL, LAP SPLICE LENGTHS AND LOCATIONS. THE SPECIAL
B) SPLICE (LAPS): SEE TABLE BELOW OR 24 INCHES, WHICHEVER IS GREATER. EPOXY
COATED BARS SHALL HAVE THEIR LAP LENGTHS 50% GREATER THAN THOSE
INSPECTOR SHALL PERFORM CONTINUOUS AND PERIODIC SPECIAL INSPECTIONS
SPECIFIED ABOVE.
PER THE CODE.
NOTES:
1. TYPICAL UNLESS OTHERWISE NOTED.
2. FOR F'm=2000psi, REDUCE LAP LENGTHS BY 15 PERCENT.
MIN. LENGTH MUST BE > 24".
REINFORCING LAP SPLICE LENGTH
MASONRY F'm = 1500 psi
BAR
SIZE
BAR
DIA. (in)
1 BAR CELL
8" CMU
#3
#4
#5
#6
#7
#8
3/8
1/2
5/8
3/4
7/8
24"
25"
31"
57"
79"
112"
12" CMU
24"
25"
31"
52"
61"
75"
2 BAR CELL
8" CMU
24"
31"
48"
98"
133"
186"
12" CMU
24"
31"
48"
98"
133"
186"
GROUTING:4.
A) ALL CELLS W/ REINFORCING SHALL BE FILLED W/ GROUT OR AS INDICATED ON THE
CONSOLIDATED: AT TIME OF PLACEMENT BY MECHANICAL VIBRATION AND THENB)
RECONSOLIDATED BEFORE PLASTICITY IS LOST.
POURS OVER 5 FEET: PROVIDE CLEANOUTS IN BOTTOM COURSE AT VERTICALC)
REINFORCEMENT. SPECIAL INSPECTION REQUIRED.
HORIZONTAL CONSTRUCTION JOINTS: FORMED BY STOPPING THE GROUT POURD)
NOT LESS THAN 1/2 INCH BELOW THE TOP OF THE UPPERMOST UNITS GROUTED.
HORIZONTAL REINFORCING SHALL BE FULLY EMBEDDED IN GROUT.
GROUT SHALL BE PLACED IN CONTINUOUS POUR IN GROUT LIFTS NOT EXCEEDINGE)
PROVED A MINIMUM OF 1/2 INCH CLEAR BETWEEN MAIN REINFORCING AND MASONRY5.
DETERMINE COMPLIANCE WITH COMPRESSIVE STRENGTH USING EITHER THE UNIT 6.
STRENGTH METHOD PER CODE SECTION 2105.3.4 OR PRISM TESTING PER CODE
REINFORCING CONGESTION: KNOCK OUT BLOCKS TO BE USED TO FACILITATE7.
DRAWINGS
SECTION 2105.3.2 OR 2105.3.3.
CONSTRUCTION.
5 FEET.
UNITS.
TOGETHER ON BOTH FLANGES WITH 1/16" GROOVE WELDS x 1" LONG AT 12" ON
CENTER. WELDING PER AWS D1.3 TYPE E-6012, E-6013 OR E-7014 ROD, SMAW PROCESS.
THROUGH METAL FRAMING.
ASSOCIATION" SPECIFICATIONS, ICC-ES ER-4943P.
ALL EXTERIOR LIGHT GAGE METAL FRAMING SHALL BE AS NOTED BELOW.
ALL LIGHT GAGE METAL FRAMING CONSTRUCTION SHALL BE IN ACCORDANCE WITH AISI
DOUBLE VERTICAL STUDS OR HORIZONTAL JOISTS SHALL BE STITCH WELDED
ALL SHEET METAL SCREWS SHALL PROTRUDE THE LARGER OF 1/4" OR 3 THREADS
ALL METAL STUDS SHALL HAVE STIFFENED FLANGES.
MINIMUM STUD AND JOIST PROPERTIES SHALL BE PER "METAL STUD MANUFACTURER'S
EXTERIOR STUDS SHALL BE 18 GA MINIMUM AND DESIGNED BY A LICENSED ENGINEER.
1.
2.
4.
5.
6.
7.
8.
"SPECIFICATIONS FOR DESIGN OF COLD FORMED STEEL STRUCTURAL MEMBERS" AND
ALL LIGHT GAGE METAL FRAMING SHALL BE MILL-CERTIFIED TO CONFORM WITH THE3.
12, 14 OR 16 GAUGE: GALVANIZED
18 GAUGE: GALVANIZED
TRACK, END ENCLOSURES, BRIDGING
AND ACCESSORIES: GALVANIZED
ASTM A653 SQ GRADE 50
ASTM A653 SQ GRADE 33, MIN.
ASTM A653 SQ GRADE 33, MIN.
UFC 3-301-01.
FOLLOWING:
CHAIRS, SPACERS AND SAND PLATES: AS REQUIRED TO MAINTAIN CONCRETEC)
315 AND ACI 318. SHOP DRAWINGS REVIEWED BY THE CONTRACTING
OFFICER BEFORE FABRICATION.
MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCEMENT:
MIN. COVER,
INCHES
CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH
CONCRETE EXPOSED TO EARTH OR WEATHER:
NO. 6 THROUGH NO. 18 BAR
NO. 5 BAR, W31 OR D31 WIRE AND SMALLER
CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH
GROUND:
SLABS, WALLS, JOISTS:
NO. 14 AND NO. 18 BAR
NO. 11 BAR AND SMALLER
BEAMS, COLUMNS:
PRIMARY REINFORCEMENT TIES:
REINFORCEMENT:
CAST-IN-PLACE CONCRETE (NON-PRESTRESSED). THE FOLLOWING
STIRRUPS, SPIRALS
6.
A) SHOP DRAWINGS, FABRICATION AND PLACING: SHALL CONFORM TO ACI
B)
1 1/2
1 1/2
3/4
1 1/2
ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, MAY BE
INCORPORATED IN THE CONCRETE DESIGN MIXES. A HIGH-RANGE WATER-REDUCING
(HRWR) ADMIXTURE CONFORMING ASTM C494, TYPE F OR G, MAY BE USED IN CONCRETE
MIXES PROVIDING THAT SLUMP DOES NOT EXCEED 9". AN AIR-ENTRAINING AGENT
CONFORMING TO ASTM C260 SHALL BE USED IN CONCRETE MIXES FOR THE EXTERIOR
A WATER-REDUCING ADMIXTURE CONFORMING TO ASTM C494, USED IN STRICT
SURFACES EXPOSED TO COLD WEATHER. THE AMOUNT OF ENTRAINED AIR SHALL BE
5.
6% ± 1% BY VOLUME.
COVER.
CEMENT
AGGREGATE
REINFORCEMENT
THE CONCRETE STRENGTHS SHOWN IN THE FOLLOWING TABLE ARE THE MINIMUM
COMPRESSIVE STRENGTHS AT 28 DAYS AND THE WATER/CEMENT RATIO IS THE
MAXIMUM. THE SPECIFIED SLUMP IS THE MAXIMUM PRIOR TO THE ADDITION OF
ADMIXTURES. CONCRETE SHALL BE STANDARD WEIGHT CONCRETE (145 PCF).
ITEM OF
CONSTRUCTION
MINIMUM OF SEVENTY PERCENT OF THE SPECIFIED 28-DAY STRENGTH FOR ANY
CONCRETE CONSTRUCTION REQUIRING SHORING, BRACING OR TO RECEIVE
MATERIALS:
CONCRETE STRENGTHS:
CONTINUOUS SPECIAL INSPECTION IS REQUIRED FOR DESIGN STRENGTHS EXCEEDING.
CONCRETE SHALL BE PROPORTIONED SUCH THAT 7-DAY STRENGTHS ARE A
1.
2.
3.
4.
ASTM C - 150
ASTM C - 33
ASTM A - 615
STRENGTH AGG SLUMP WATER/CEMENT
(PSI) (IN) (IN) (LB/LB)
2,500 PSI.
CONSTRUCTION LOADS.
TYPE I I
CRUSHED ROCK
GRADE 60 TYPICAL
STRUCTURAL SLABS (INTERIOR) 4,500 1 6 0.45
(NOT AIR ENTRAINED)
CORNER OF RECTANGULAR HOLES IN SLABS. PLACE BARS DIAGONALLY.
SLAB CORNERS: PROVIDE (2)-#4 X 4'-0" AT RE-ENTRANT CORNERS AND EACHH)
THE SAME SIZE AND SPACING OF REINFORCEMENT AS SHOWN ON THE DRAWINGS
AND IN THE GENERAL NOTES.
COLUMN BEAM SHALL EXTEND TO WITHIN 2" OF THE FACE AND HAVE A 90 DEGREE
HOOK UNLESS OTHERWISE SHOWN.
REINFORCING BARS BUNDLED IN CONTACT TO ACT AS A UNIT IN A LAYER SHALL
NOT BE LESS THAN 1-1/2 TIMES THE NOMINAL DIAMETER OF THE REINFORCEMENT
OR 1-1/3 TIMES MAXIMUM SIZE AGGREGATE, NOR LESS THAN 1-1/2". NORMAL
DIAMETER FOR A UNIT OF BUNDLED BARS SHALL BE THE EQUIVALENT DIAMETER
OF THE COMBINED AREAS OF THE BARS BUNDLED.
VERTICAL REINFORCEMENT: SHALL BE DOWELED TO SUPPORTING MEMBERS WITH
HORIZONTAL REINFORCEMENT: ALL BARS ENDING AT THE FACE OF A WALL,
SPACING: CLEAR DISTANCE BETWEEN PARALLEL REINFORCEMENT OR PARALLEL
TACK WELDING, WELDING, HEATING OR CUTTING OF BARS: NOT PERMITTED U.N.O.
D)
E)
F)
G)
87 EQUIVALENT BAR DIAMETERS FOR BOTTOM BUNDLES AND 113 EQUIVALENT
BAR DIAMETERS FOR TOP BUNDLES, WHERE THE EQUIVALENT DIAMETER IS
BASED UPON THE COMBINED AREAS OF THE BARS BUNDLED. LAP LENGTHS
FOR BARS IN BUNDLES OF 4 OR MORE BARS SHALL BE INCREASED AN
ADDITIONAL 11 PERCENT.
WITH E90XX ELECTRODES.
PRIOR TO FOUNDATION INSPECTION BY THE SPECIAL INSPECTOR AND OBSERVATION
BY THE CONTRACTING OFFICER.
FOOTING OR COLUMNS UNLESS SPECIFICALLY DETAILED.
ADMIXTURES: REVIEWED BY CONTRACTING OFFICER, NO CALCIUM CHLORIDE.
THOROUGHLY CLEAN ALL CONCRETE SURFACES TO RECEIVE NEW CONCRETE.
LOCATION OF JOINTS SHALL BE REVIEWED BY THE CONTRACTING OFFICER. WAIT 48
ACTUAL DIMENSIONS: SLAB, WALL, BEAM AND COLUMN DIMENSIONS SHOWN ARE
ACTUAL DIMENSIONS NOT NOMINAL DIMENSIONS (i.e. A 4 INCH SLAB IS 4 INCHES
THICK, NOT 3-1/2 INCHES.)
INDIVIDUAL SPLICES OF BARS IN A BUNDLE SHALL BE STAGGERED AT LEAST
ALL LAP SPLICES ARE CLASS B UNLESS OTHERWISE NOTED ON PLANS.
WELDED REINFORCEMENT: ASTM A-706, CERTIFIED WELDERS. WELD PER AWS D1.4
PIPES, SLEEVES AND DUCTS: SHALL NOT BE PLACED IN WALLS, BEAMS, SLABS,
CHAMFER: 3/4 INCH ON EXPOSED CORNERS.
CONSTRUCTION JOINTS: HEAVY SANDBLAST (1/4 INCH AMPLITUDE MINIMUM) AND
iv) v)
J)
ANCHOR BOLTS, DOWELS AND HOLD-DOWN ANCHORS: SECURELY HELD IN PLACE7.
8.
9.
10.
11.
13.
PLANE JOINTS NOT SPECIFICALLY INDICATED ON THE DRAWINGS SHALL BE REVIEWED
BY THE CONTRACTING OFFICER PRIOR TO THE PLACING OF REINFORCEMENT.
SLAB-ON-GRADE JOINTS: LOCATION OF ALL CONSTRUCTION, CONTROL AND WEAKENED12.
HOURS BETWEEN POURS.
SPLICES IN OTHER BOTTOM REINFORCEMENT; STAGGER SPLICES FOR TOP
REINFORCEMENT SIMILARLY.
SPLICES (LAPS) U.N.O.
IN NO CASE SHALL LAPS BE LESS THAN 24 INCHES LONG.
STAGGER CONTINUOUS FOOTING BOTTOM SPLICES AT LEAST 6'-0" FROM
I)
i) SEE TABLE A, CONCRETE LAP SPLICE PER SCHEDULE ON S-601, FOR TENSION ii) iii)
LAP SPLICE LENGTHS.
ELECTRICAL CONDUIT IS NOT ALLOWED TO BE PLACED IN THE CONCRETE SLAB.15.
CONCRETE CURING: SEE SPECIFICATIONS.14.
SHEET ID
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R
IN
G C
E N
T E
R
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
R
B R
E N
O V
A T
IO
N
A u to d e s k D o c s /0
-0
-J
B M
D L B
B
/0
-0
-J
B M
D L -B
B
L a b E x p a n s io n S
.r v t
/1
/2
:4
:2
A
M
S-002B
G E
N E
R A
L S
T R
U C
T U
R A
L N
O T
E S
J B
M D
L L a k e h u rs t, N
J A
M
A G
IN
N
IS
A M
A G
IN
N
IS
C T
R A
N
J A
N U
A R
Y
F A
D
F
IN
A L
S U
B M
IT
T
A L
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
-0
D C
A V
IN
MASONRY EXTERIOR BEARING AND NON-BEARING METAL STUDS
REINFORCED CONCRETE
REINFORCED CONCRETE (CONTINUED)
1 3 4
B
A
C
D
E
F
G
16' - 0" 14' - 5" 11' - 7"
5 5
40' - 0"
(FIELD VERIFY)
SHEET ID
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R
IN
G C
E N
T E
R
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
R
B R
E N
O V
A T
IO
N
A u to d e s k D o c s /0
-0
-J
B M
D L B
B
/0
-0
-J
B M
D L -B
B
L a b E x p a n s io n S
.r v t
/1
/2
:4
:2
A
M
S-101B
F O
U N
D A
T
IO
N P
L A
N
J B
M D
L L a k e h u rs t, N
J A
M
A G
IN
N
IS
A M
A G
IN
N
IS
C T
R A
N
J A
N U
A R
Y
F A
D
F
IN
A L
S U
B M
IT
T
A L
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
-0
D C
A V
IN
1/8" = 1'-0"A1
FOUNDATION PLAN
0 4' 8' 16'
PLAN NORTH
GENERAL SHEET NOTES
1. TOP OF (EXISTING) FINISHED FLOOR 0'-0" U.N.O.
2. FIELD VERIFY EXISTING CONDITIONS.
1. EXISTING BUILDING 331
2. NEW ADDITION BUILDING (NOT IN SCOPE)
3. EXISTING BUILDING 332 (NOT IN SCOPE)
4. (NOT USED)
5. TUCKPOINT EXISTING CRACKS IN CMU AT WINDOW OPENINGS.
6. (NOT USED)
7. PIPE BOLLARD EMBEDDED THROUGH EXISTING 5" SLAB, OR
NEW OR EXISTING 4" STOOP (SEE K6 ON S-501B).
SHEET KEYNOTES
18" DIA. CONCRETE FOOTING
6" DIA. STD. PIPE BOLLARD
CONCRETE-FILLED, PAINTED
YELLOW
EXISTING SLAB-ON-
GRADE OR APRON
EXISTING SLAB-ON-
GRADE OR APRON
SLOPE CONCRETE
ABOVE GRADE
ISOLATION JOINT (TYP.)
(T Y
P
ROUND CONCRETE TOP
SAW CUT EXISTING SLAB ON
GRADE OR BUILDING APRON TO
ALLOW FOR NEW BOLLARD AND
SUBGRADE CONCRETE
SHEET ID
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R
IN
G C
E N
T E
R
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
R
A D
D
IT
IV
E
L A
B A
D D
IT
IO
N
A u to d e s k D o c s /0
-0
-J
B M
D L B
B
/0
-0
-J
B M
D L -B
B
L a b E x p a n s io n S
.r v t
/1
/2
:4
:2
A
M
S-501B
T Y
P
IC
A L C
O N
C R
E T
E D
E T
A
IL
S
J B
M D
L L a k e h u rs t, N
J A
M
A G
IN
N
IS
A M
A G
IN
N
IS
C T
R A
N
J A
N U
A R
Y
F A
D
F
IN
A L
S U
B M
IT
T
A L
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
-0
D C
A V
IN
3/4" = 1'-0"K6
BOLLARD ELEVATION AT SLAB-ON-GRADE
0 0.5' 1' 2' 3'
DRAWING ABBREVIATIONS
NOTE: THE ABOVE ABBREVIATIONS ARE
STANDARD AND ARE NOT INTENDED AS A
LISTING OF ALL ABBREVIATIONS ON THE JOB.
SYMBOLS LEGEND
A10 VIEW OR DETAIL TITLE
SCALE
DETAIL IDENTIFICATION NUMBER (LOCATION ON
SHEET GRID)
PLAN NORTH
APPROPRIATE BAR SCALE WHERE APPLICABLE
A10
AE201
AI201A4 A8
A6
A10
A10
AE301
A10
AE301
EXTERIOR ELEVATION
INTERIOR ELEVATION
SECTION
DETAIL CALLOUT
NORTH ARROW W/ TRUE NORTH INDICATOR
ELEVATION IDENTIFICATION NUMBER
SHEET WHERE ELEVATION IS LOCATED
SECTION IDENTIFICATION NUMBER
SHEET WHERE SECTION IS LOCATED
ELEVATION IDENTIFICATION NUMBER
SHEET WHERE ELEVATION IS LOCATED
DETAIL IDENTIFICATION NUMBER
SHEET WHERE DETAIL IS LOCATED
AREA COVERED
BY DETAIL
1 SHEET KEYNOTE
A WINDOW TAG
A1 PARTITION TYPE TAG
ROOM NAME
ROOM TAG101
101A DOOR TAG
LEVEL NAME LEVEL TAG10'-0"
1 REVISION TAG
MATERIAL LEGEND
FOR PLANS AND DETAILS
CONCRETE MASONRY UNITS
CONCRETE
RIGID INSULATION
STUCCO
EXTERIOR INSULATION AND
FINISH SYSTEM
BRICK
ALUMINUM
STEEL
FINISHED WOOD
EARTH
SPRAY FOAM INSULATION
BATT INSULATION
NOTE: THE ABOVE MATERIAL INDICATIONS ARE
STANDARD AND ARE NOT INTENDED AS A
LISTING OF MATERIALS ON THE JOB
WIDE FLANGE STEEL COLUMN
SQUARE STEEL COLUMN
ROUND STEEL COLUMN
SQUARE CONCRETE COLUMN
GENERAL DISCIPLINE NOTES
BUILDING SUMMARY
A. HAT CHANNELS RUN VERTICAL IN SECTION FOR CLARITY.
B. PIPE SLEEVES, FRAMED OPENINGS AND ANY MISC. OPENINGS SHOWN ON
ARCH. DWGS THAT ARE SIZED AND/OR LOCATED MUST BE INSTALLED AS
INDICATED ON THE ARCH DWGS AND IN ACCORDANCE WITH THE APPLICABLE
DETAILS AS REFERENCED ON THE ARCH DWGS.
C. PIPE SLEEVES, FRAMED OPENINGS AND ANY MISC. OPENINGS ON ANY ARCH
DWGS THAT ARE NOT SIZED AND/OR LOCATED MUST BE SIZED AND LOCATED AS
INDICATED ON THE APPLICABLE HVAC, MECH, STRUCT, OR ELEC DWGS. THESE
OPENINGS MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE ARCH
DETAILS AS REFERENCED ON THE DWGS.
D. PIPE SLEEVES, FRAMED OPENINGS AND ANY MISC. OPENINGS NOT SHOWN ON
THE ARCH DWGS MUST BE SIZED AND LOCATED AS INDICATED ON THE
APPLICABLE HVAC, MECH, STRUCT, OR ELEC DWGS. THE ARCH DWGS MUST BE
USED AS A REFERENCE FOR THE INSTALLATION OF THESE OPENINGS.
E. EQUIPMENT LAYOUTS FOR MECH AND ELEC AREAS ARE SHOWN ON THE MECH
AND ELEC DWGS.
F. SIDEWALKS, DRIVES AND OTHER SITE WORK ARE SHOWN ON THE CIVIL DWGS.
G. FOR STRUCTURAL STEEL, REINFORCING BARS, CONCRETE AND OTHER
STRUCTURAL MATERIALS, SEE STRUCTURAL DWGS AND SPECIFICATIONS.
H. REFER TO ROOM FINISH SCHEDULE FOR FINISH CEILING HEIGHTS.
I. WALLS INDICATED AS PAINTED (IN ROOMS RECEIVING ACOUSTICAL CEILING)
ARE TO BE PAINTED MINIMUM 4" ABOVE CEILING.
J. CEILING PANELS AND METAL TRIM TO BE CUT AND FITTED TO PROVIDE A
CLEAN AND NEAT CONDITION.
K. PAINTING CONTRACTOR MUST INVESTIGATE ALL PRIMED SURFACES TO
RECEIVE FINISH COATING FOR COMPATIBILITY. WHERE NON-COMPATIBLE
PRIMERS EXIST, A BARRIER COAT MUST BE APPLIED PRIOR TO APPLICATION OF
FINISH COAT.
L. SHOP DRAWING REVIEW IS FOR GENERAL COMPLIANCE WITH THE
ARCHITECTURAL DOCUMENTS. RESPONSIBILITY FOR QUANTITIES AND
DIMENSIONS LIES SOLELY WITH THE CONTRACTOR .
M. CONTRACTOR MUST VERIFY ALL DIMENSIONS, ELEVATIONS AND SITE
CONDITIONS PRIOR TO BEGINNING WORK. NOTIFY CONTRACTING OFFICER
REPRESENTATIVE IMMEDIATELY OF ANY DISCREPANCIES.
N. PREVENT THE SPREAD OF DUST AND DEBRIS TO OCCUPIED PORTIONS OF
THE BUILDING AND AVOID THE CREATION OF A NUISANCE OR HAZARD IN THE
SURROUNDING AREA. DO NOT USE WATER IF IT RESULTS IN HAZARDOUS OR
OBJECTIONABLE CONDITIONS SUCH AS, BUT NOT LIMITED TO, ICE, FLOODING,
OR POLLUTION. VACCUUM AND DUST THE WORK AREA BEFORE TURNING OVER
TO THE GOVERNMENT.
O. ARCHITECTURAL 0'-0" IS EQUAL TO 90.15', RE: CIVIL
SHEET NUMBERING SYSTEM
XX100
DISCIPLINE:
C - CIVIL
L - LANDSCAPE
A - ARCHITECTURE
M - MECHANICAL
E - ELECTRICAL
P - PLUMBING
S - STRUCTURAL
K - FOOD SERVICE
DISCIPLINE MODIFIER
SHEET NUMBER WITHIN SERIES
CONTROL JOINT
FEATHER EDGES
SEALANT
STEEL STUDS
INSTALL BOXED STUDS AT
VERTICAL WALL
ATTACHMENTS (TOILET
PARTITIONS, URINAL
SCREENS, SHOWER
BENCHES, HAND RAILS,
DOOR STOPS)
FRAMING DETAILS
NOTE: CONTROL JOINTS ARE TO BE PLACED AT ALL GYPSUM
BOARD WALL AND CEILING SURFACES THAT EXCEED 30 FEET
MAXIMUM IN ANY DIRECTION.
PARTITION CONTROL JOINT - TYPICAL
VERTICAL WALL ATTACHMENT FRAMING - TYPICAL
A --------------------
ACM ASBESTOS CONTAINING MATERIAL
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
ACS DR ACCESS DOOR
ACS PNL ACCESS PANEL
ACC ACCESSIBLE
ACCS ACCESSORIES
ACT ACOUSTICAL CEILING TILE
ADJ ADJUSTABLE
ALUM ALUMINUM
ANDZ ANODIZED
A/C AIR CONDITIONING
& AND
APPD APPROVED
APPROX APPROXIMATE(LY)
A/E ARCHITECT/ENGINEER
ARCH. ARCHITECTURAL
ABA ARCHITECTURAL BARRIERS ACT
ASSY ASSEMBLY
@ AT
A/V AUDIO/VISUAL
AVG AVERAGE
B --------------------
BRG BEARING
B.M. BENCH MARK
BTM BOTTOM
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BD BOARD
BDRY BOUNDRY
BR BRICK
B.U. BUILT UP
C --------------------
CPT CARPET
CI CONTINUOUS INSULATION
CTR CENTER
CL CENTERLINE
CLG CEILING
CMU CONCRETE MASONRY UNIT
CFCI CONTRACTOR FURNISHED/
CONTRACTOR INSTALLED
CJ CONTROL JOINT
COL COLUMN
COMM COMMUNICATION(S)
CONC CONCRETE
CONF CONFERENCE
CONT CONTINUOUS
COORD COORDINATE
COR CONTRACTING OFFICERS
REPRESENTATIVE
CORR CORRIDOR
CO CLEAN OUT
CLR CLEAR
CONTR CONTRACTOR
D --------------------
DEMO DEMOLITION
DEPT DEPARTMENT
D DEPTH
DET DETAIL
DIA DIAMETER
DIM DIMENSION
DIR DIRECTION
DIST DISTANCE
D.F. DRINKING FOUNTAIN
DBL DOUBLE
DN DOWN
DOC DOCUMENT
DS DOWNSPOUT
DR DOOR
D.O. DOOR OPENING
DWG DRAWING
E --------------------
EA EACH
E EAST
ELEC ELECTRICAL
EWC ELECTRIC WATER COOLER
EL ELEVATION
ELEV ELEVATOR
ENTR ENTRANCE
EQ EQUAL
EXIST EXISTING
EJ EXPANSION JOINT
EXT EXTERIOR
EIFS EXTERIOR INSULATION AND FINISH
SYSTEM
EXP EXPOSED
EXP.STR. EXPOSED STRUCTURE
ENG ENGINEER
F --------------------
FSTNR FASTENER
FGRG FIBERGLASS REINFORCED
GYPSUM
FIN FINISH
FF FINISHED FACE
FIN FLR FINISHED FLOOR
FIN GRD FINISHED GRADE
FA FIRE ALARM
FH FIRE HYDRANT
FE FIRE EXTINGUSHER
FEC FIRE EXTINGUSHER CABINET
FHC FIRE HOSE CABINET
FIXT FIXTURE
FLR FLOOR
FD FLOOR DRAIN
FLUOR FLUORESCENT
FTG FOOTING
FDN FOUNDATION
FRMG FRAMING
FRP FIBERGLASS REINFORCED PLASTIC
FT FOOT (FEET)
G --------------------
G.I. GALVANIZED IRON
GL GRID LINE
GA GAUGE
GALV GALVANIZED
GLAZ GLAZING
GFCI GOVERNMENT FURNISHED/
CONTRACTOR INSTALLED
GFGI GOVERNMENT FURNISHED/
GOVERNMENT INSTALLED
GOVT GOVERNMENT
GYP GYPSUM
GYP BD GYPSUM BOARD
H --------------------
HC HANDICAPPED
HDWR HARDWARE
HDWD HARDWOOD
HD HEAD
HVAC HEATING VENTILATION & AIR
CONDITIONING
HT HEIGHT
HM HOLLOW METAL
HORIZ HORIZONTAL
HB HOSE BIB
I ---------------------
IAW IN ACCORDANCE WITH
IBC INTERNATIONAL BUILDING CODE
IN INCH(ES)
ID INSIDE DIAMETER
IM INSULATED METAL
INSUL INSULATION
INT INTERIOR
J ---------------------
JST BRG JOIST BEARING
JT JOINT
JAN JANITOR
K --------------------
KO CONTRACTING OFFICER
KPD KEYPAD
KPL KICKPLATE
KIT KITCHEN
L --------------------
LAM LAMINATE
LDG LANDING
LAV LAVATORY
LH LEFT HAND
LHR LEFT HAND REVERSE
LT LIGHT
LTG LIGHTING
LIN LINEAR
LF LINEAR FEET (FOOT)
LOC LOCATION
LONG. LONGITUDE
LG LONG
LVR LOUVER
LP LOW POINT
LMBR LUMBER
M -------------------
MFR MANUFACTURER
M.O. MASONRY OPENING
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEMB MEMBRANE
MTL METAL
MWP METAL WALL PANEL
MIN MINIMUM
MISC MISCELLANEOUS
MOD MODIFY
MB MOISTURE BARRIER
N --------------------
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NOM NOMINAL
N NORTH
NA NOT APPLICABLE
N.I.C. NOT IN CONTRACT
N.T.S. NOT TO SCALE
NO. NUMBER
O --------------------
OFC OFFICE
OC ON CENTER
OPNG OPENING
OPP OPPOSITE
OH OPPOSITE HAND
ORIG ORIGINAL
OA OVERALL
OD OVERFLOW DRAIN
OS OVERFLOW SCUPPER
P --------------------
PTD PAINTED
PR PAIR
PNL PANEL
PAR PARAPET
PTN PARTITION
PAT PATTERN
PERF PERFORATED
PERIM PERIMETER
PLAS PLASTER
PLAM PLASTIC LAMINATE
PL PLATE
PLBG PLUMBING
PLYWD PLYWOOD
PWR POWER
PA PUBLIC ADDRESS
Q --------------------
QTY QUANTITY
R --------------------
R RADIUS OR RISER
RLG RAILING
RECEP RECEPTIONIST
REC RECESSED
REF/RE: REFER OR REFERENCE
RCP REFLECTED CEILING PLAN
REINF REINFORCING
REP REPAIR
REPL REPLACE
REQ REQUIRED
RES RESILIENT
RB RESILIENT BASE
RF RESILIENT FLOORING
REST RESTROOM
RVL REVEAL
REV REVISIONS/REVISED
RH RIGHT HAND
RHR RIGHT HAND REVERSED
RD ROOF DRAIN
RFG ROOFING
RM ROOM
RO ROUGH OPENING
S ---------------------
SCHED SCHEDULE
SHT SHEET
SHT MTL SHEET METAL
SIM SIMILAR
SGL SINGLE
SCW SOLID CORE WOOD
S.C. SOLID CORE
SJ SCORED JOINT
S.O.W. SCOPE OF WORK
S SOUTH
SPEC SPECIFICATION(S)
SQ SQUARE
SF SQUARE FOOT (FEET)
SQ IN SQUARE INCH(ES)
SST STAINLESS STEEL
ST STAIR(S)
STD STANDARD
STL STEEL
STL JST STEEL JOIST
STOR STORAGE
STRUCT STRUCTURAL
T ---------------------
TEL TELEPHONE
TV TELEVISION
TEMP TEMPORARY
THK THICKNESS
T.O. TOP OF
T.O.C. TOP OF CURB
T.O.F. TOP OF FOOTING
T.O.M. TOP OF MASONRY
T.O.P. TOP OF PARAPET
T.O.S. TOP OF STEEL
T.O.W. TOP OF WALL
TOPO TOPOGRAPHY
TRANS TRANSOM
T TREAD
TRTD TREATED
TD TRENCH DRAIN
TYP TYPICAL
U --------------------
UNO UNLESS NOTED OTHERWISE
V --------------------
VER VERIFY
VIF VERIFY IN FIELD
VERT VERTICAL
VCT VINYL COMPOSITION TILE
W -------------------
WC WATER CLOSET
W WEST
W/ WITH
WD WOOD
SITE AREA: RE: CIVIL
RENOVATION SF: +/- 4,000 SF
EXISTING SF: +/- 13,000 SF
GROSS BUILDING SF +/- 13,000 SF
NUMBER OF STORIES: 1
BUILDING SPRINKLED: YES
APPLICABLE CODES: NFPA 101 LIFE SAFETY CODE (NFPA),
INTERNATIONAL BUILDING CODE (IBC),
OCCUPANCY: FACTORY - MODERATE HAZARD
CONSTRUCTION CLASSIFICATION: TYPE IIB
SHEET ID
AI
R
F O
R C
E C
IV
IL
E N
G
IN
EE
R
IN
G
C
EN
TE
R
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Fi le
P at h:
Pl ot D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
D R
EM
Y
Au to de sk
D oc s:
//0
9-
-J
BM
D
L B3
B
2/
JB
M
D L
1_
La b
Ex pa ns io n_ A2
3.
rv t 1/
/2
:5
1:
A M
A-001B
LE
G
EN
D
S, A
BB
R
EV
IA
TI
O
N
G
EN
ER
AL
N O
TE
S
JO
IN
T
BA
SE
M
C G
U
IR
E- D
IX
-L
AK
EH
U R
ST
, L
AK
EH
U R
ST
N
J D
R
EM
Y
M R
O
BI
N
SO
N
Q R
EM
Y
JA
N
U
AR
Y
M
SB
L
-4
FI
N
AL
S
U
BM
IT
TA
L
- I
SS
U
ED
F
O R
C O
N
ST
R U
C
TI
O N
B3
R
EN
O
VA
TI
O
5/8" GYPSUM WALL BOARD,
EACH SIDE
METAL STUDS
METAL TRACK
LINE OF DECK
SOUND ATTENUATING BATT INSULATION
METAL TRACK
F.F.
A1 NON-RATED PARTITION - 1 LAYER 5/8" GYPSUM WALL BOARD
EACH SIDE, ON 3 5/8" STUD FRAMING WITH GLASS FIBER
INSULATION
SCHEDULED BASE OVER
GYPSUM WALL BOARD,
RE: ROOM FINISH SCHEDULE
CONTINUOUS SEALANT, BOTH SIDES
CONTINUOUS SEALANT, BOTH SIDES
SHEET ID
AI
R
F O
R C
E C
IV
IL
E N
G
IN
EE
R
IN
G
C
EN
TE
R
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Fi le
P at h:
Pl ot D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
D R
EM
Y
Au to de sk
D oc s:
//0
9-
-J
BM
D
L B3
B
2/
JB
M
D L
1_
La b
Ex pa ns io n_ A2
3.
rv t 1/
/2
:5
1:
A M
A-002B
W
AL
L
TY
PE
S
JO
IN
T
BA
SE
M
C G
U
IR
E- D
IX
-L
AK
EH
U R
ST
, L
AK
EH
U R
ST
N
J D
R
EM
Y
M R
O
BI
N
SO
N
Q R
EM
Y
JA
N
U
AR
Y
M
SB
L
-4
FI
N
AL
S
U
BM
IT
TA
L
- I
SS
U
ED
F
O R
C O
N
ST
R U
C
TI
O N
B3
R
EN
O
VA
TI
O
N
GENERAL SHEET NOTES
1 STUD SUPPLIER IS RESPONSIBLE FOR GAUGE AND
BRACING REQUIREMENTS, UNLESS NOTED
OTHERWISE
2 REFER TO ROOM FINISH SCHEDULE FOR CEILING
HEIGHTS
3 MOISTURE/MOLD RESISTANT GYPSUM WALL BOARD IS
REQUIRED FOR THE INTERIOR FACE OF ALL EXTERIOR
WALLS
EXISTING B332 EXISTING ADDITIVE LAB RENOVATE
B331
SHEET ID
AI
R
F O
R C
E C
IV
IL
E N
G
IN
EE
R
IN
G
C
EN
TE
R
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Fi le
P at h:
Pl ot D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
D R
EM
Y
Au to de sk
D oc s:
//0
9-
-J
BM
D
L B3
B
2/
JB
M
D L
1_
La b
Ex pa ns io n_ A2
3.
rv t 1/
/2
:5
1:
A M
A-101B
AR
EA
O F
W O
R K
PL
AN
JO
IN
T
BA
SE
M
C G
U
IR
E- D
IX
-L
AK
EH
U R
ST
, L
AK
EH
U R
ST
N
J D
R
EM
Y
M R
O
BI
N
SO
N
Q R
EM
Y
JA
N
U
AR
Y
M
SB
L
-4
FI
N
AL
S
U
BM
IT
TA
L
- I
SS
U
ED
F
O R
C O
N
ST
R U
C
TI
O N
B3
R
EN
O
VA
TI
O
N
1/8" = 1'-0"A4 AREA OF WORK PLAN
0' 2' 4' 8' 16'
PLAN NORTH
GENERAL SHEET NOTES
1 AREA OF WORK TO BE THE RENOVATION OF EXISTING
B331. ALL DOORS, WINDOWS, AND INTERIOR PARTITION
WALLS ARE TO BE REMOVED AND REPLACED.
CR
BMSSR
BMS
CR
SR
BM
S
BMS BMSBMSBMSBMS
BM
S
CR SR
CRSR
BMS
BMS
S
ZONE 2
(INSPECTION ONLY)
ZONE 1
(INSPECTION ONLY)
EXISTING B332 EXISTING ADDITIVE LAB
AIR BARRIER LEGEND
ZONE 1 (INSPECTION ONLY)
ZONE 2 (EXISTING)
AIR BARRIER ZONE CALCULATIONS
ZONE FLOOR NORTH EAST…
This is the start of the file's text. The full file is on GovTribe.