Amendment 3 _ Cullum H-1B2_HAZMAT_PLAN_BASEMENT_LEVEL_2.pdf

PDF 410 KB Posted

Attached to
Cullum Hall Repair Building 605
Solicitation number
W912DS21R0003
Issued by

About this file

This document includes plans for hazardous material abatement and a related federal contract opportunity for repair work. The plans depict the basement level of Building 605 at the United States Military Academy and identify locations of asbestos-containing materials and lead-based paint through standard symbols. The plans will be used to guide abatement and demolition work required under the repair contract. The solicitation seeks bids for repair of Building 605 issued by the Department of the Army Corps of Engineers Engineering District New York. The opportunity number is W912DS21R0003 and involves hazardous material abatement, repairs, and renovations to prepare the building for future use. The required work includes removal of asbestos, lead, and other hazardous materials in accordance with the abatement specifications and mitigation plans provided.

View the file

Other files

File Type Posted
W912DS21R0003 Amendment 00009.pdf PDF
W912DS21R0003 Amendment 00008.pdf PDF
W912DS21R0003 Amendment 00007.pdf PDF
CULLUM_Amendment 7_Drawings Combined.pdf PDF
CULLUM_Amendment 7_Specifications Combined.pdf PDF
CULLUM_Amendment 6_Specs Combined.pdf PDF
CULLUM_Amendment 6_Drawings Combined.pdf PDF
W912DS21R0003 Amendment 00006.pdf PDF
W912DS21R0003 Amendment 00005.pdf PDF
Cullum Hall Site Visit Sign In Roster 20APR2021.pdf PDF
Cullum Site Visit Sign In Roster 4 May 2021.pdf PDF
W912DS21R0003 Amendment 00004.pdf PDF
Amendment 3_Cullum_C-502.pdf PDF
Amendment 3 Demolition Sheets.pdf PDF
W912DS21R0003 Amendment 00003.pdf PDF
CULLUM_Amendment 3_Specifications Combined.pdf PDF
CULLUM_Amendment 3_Drawings Combined.pdf PDF
W912DS21R0003 Amendment 00002.pdf PDF
CULLUM_Amendment 1_Drawings Combined.pdf PDF
W912DS21R0003 Amendment 00001.pdf PDF
CULLUM_Amendment 1_Specifications Combined.pdf PDF
CULLUM RTA SPECS - VOLUME 1.pdf PDF
CULLUM RTA DRAWINGS - VOLUME 1.pdf PDF
CULLUM RTA DRAWINGS - VOLUME 3.pdf PDF
CULLUM RTA DRAWINGS - VOLUME 2.pdf PDF
CULLUM RTA SPECS - VOLUME 2.pdf PDF
JA -Milford Granite.pdf PDF
JA -E Shark 200 Meters.pdf PDF
JA-Distributed Antenna System C Squared systems.pdf PDF
JA- Hirsch Card Access system.pdf PDF
W912DS21R0003.pdf PDF
JA -Monaco Cullum.pdf PDF
JA -Best Hardware Lock Cylinders and Cores.pdf PDF
Show all 33

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CLUB/STOR

CH-B206

COAL SHOOT

CH-B208

UNASSIGNED /

UNFINISHED

CH-B212

UNASSIGNED /

UNFINISHED

CH-B214

UNASSIGNED /

UNFINISHED

CH-B218

STOR.

CH-B202

CLUB/STOR

CH-B204D

CLUB/STOR

CH-B204C

CLUB/STOR

CH-B204B

CLUB/STOR

CH-B204A

CORR

CH-B2C2

CLUB/STOR

CH-B200A

CLUB/STOR

CH-B200B

CLUB/STOR

CH-B200C

CLUB/STOR

CH-B200D

CLUB/STOR

CH-B200E

CORR

CH-B2C1

VESTIBULE

CH-B205

CLUB/STOR

CH-B211A

CLUB/STOR

CH-B211B

CLUB/STOR

CH-B211C

CLUB/STOR

CH-B213A

CLUB/STOR

CH-B213B

EXIST. ELEC

CH-B210A

EXIST. MECH

CH-B210B

EX. MECH. STAIR

CH-B210C

CLUB/STOR

CH-B216B

CLUB/STOR

CH-B216C

CLUB/STOR

CH-B216D

CORR

CH-B216A

CLUB/STOR

CH-B203

CLUB/STOR

CH-B217

VEST

CH-B219

TOILET

CH-B201

EW1 EW2 EW3 EW4

NS1

NS2

2.5

CH-B217.1

C H

B

OPEN TO

BELOW

C H

B

C H

B

B

B

42 43 44 45

SOUTHEAST

STAIR

CH-B1S2

12 27 28 47

54 5552 53

12 27 28 54 5552 53 12 27 28 47 54 5552 53 12 27 28 47 54 5552 53

27 28 47 52 5331 51504948

59 6057 581

61 62 63 64

65 66 67

12 27 28 47

54 5552 53

12 27 28 47

54 5552 53

12 27 28 47 54 5552 53

27 28 47

5452 53

27 28

12 27 28 47 54 5552 53

SCALE: 1/8"=1'-0"

0 84

US Army Corps of Engineers ®

SHEET ID

U S

A

R M

Y

C

O R

P

O

F

E

N G

I N

E E

R S

D R

A W

N

B

Y

D E

S I G

N E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

C H

E C

K E

D

B

Y

A N

S I

D

I S

S U

E

D

A T

E

C O

N T

R A

C T

N

S O

L I C

I T

A T

I O

N

N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R I P

T I O

N

P R

O J E

C

N

PLAN NORTH

H-1B2

H A

Z M

L A

N

B

A S

E M

E N

T

L

E V

E L

W E

I N

T

N

Y

A T

L R

S

K G

W D

S R

W D

S C

100% SUBMISSION 12/22/2020

U S

M

B

U I L D

I N

G

C

U L L U

M

H

A L L

R

E N

O V

A T

I O

N

SCALE: 1/8" = 1'-0"H-1B2

HAZMAT PLAN - BASEMENT LEVEL B2A1

1. NOT ALL OF THE ACMS DEPICTED ON THE DRAWINGS WILL REQUIRE

ABATEMENT. REFER TO THE ARCHITECTURAL, MECHANICAL, PLUMBING,

AND ELECTRICAL DRAWINGS FOR ALL ITEMS THAT WILL REQUIRE REMOVAL.

ASBESTOS NOTES

1. OSHA'S LEAD IN CONSTRUCTION STANDARD APPLIES TO ALL DISTURBANCES OF

LEAD BASED PAINT. IN ADDITION, THE CONTRACTOR SHALL USE METHODS TO

LIMIT THE AMOUNT OF DUST PRODUCED DURING DEMOLITION OF ANY WALL AND

CEILINGS CONTAINING LEAD BASED PAINT. ICRA DUST CONTROLS SHALL BE

UTILIZED AT ALL TIMES.

LEAD BASED PAINT NOTES

LEAD BASED PAINT SAMPLE SYMBOLSASBESTOS SAMPLE SYMBOLS

1.

2.

GENERAL NOTES

THIS DRAWING IS DIAGRAMMATIC AND IS TO BE USED FOR GENERAL

INFORMATION AND SAMPLE LOCATIONS.

SEE THE SPECIFICATIONS DOCUMENT FOR THE HAZARDOUS MITIGATION PLAN,

DIVISION 02 ABATEMENT SPECIFICATIONS 02 82 00, 02 83 00, 02 84 10, AND 02 85 00

AND THE ASBESTOS CONTAINING MATERIALS SURVEY REPORT BY OAK GROUP

FROM THE MASON AND HANGER PDR FOR MORE INFORMATION.

SYMBOL KEY

- DESIGNATION FOR LEAD BASED PAINT CONTAINING MATERIALS

- DESIGNATION FOR ASBESTOS CONTAINING MATERIALS

- EXIST WALLS, DOORS TO REMAIN (SHOWN SCREENED)

- DEMOLITION WALLS, DOORS TO BE DEMOLISHED

(SHOWN DASHED)

3. ACCESSIBLE SPACES WERE SURVEYED FOR SUSPECT ASBESTOS

MATERIALS AND LEAD BASED PAINT. WHERE OBSERVED, THE MATERIALS ARE

NOTED ON THE PLANS.

Sheets and Views
H-1B2

File details come from the government source that posted it. Updated .