JB MDL KC-46A Two-Bay General Purpose MX Hangar PTFL163019 Edited By Amendment
SECTION TABLE OF CONTENTS
DIVISION 10 - SPECIALTIES
SECTION 10 14 00.20
INTERIOR SIGNAGE
08/17
PART 1 GENERAL
1.1 REFERENCES
1.2 SUBMITTALS
1.3 EXTRA MATERIALS
1.4 QUALITY ASSURANCE
1.4.1 Samples
1.4.2 Detail Drawings
1.5 DELIVERY, STORAGE, AND HANDLING
1.6 WARRANTY
PART 2 PRODUCTS
2.1 STANDARD PRODUCTS
2.2 ROOM IDENTIFICATION/DIRECTIONAL SIGNAGE SYSTEM
2.2.1 Standard Room Signs
2.2.2 Changeable Message Strip Signs
2.2.3 Type of Mounting For Signs
2.2.4 Graphics
2.2.4.1 Graphic Blast Raised Copy
2.2.5 Character Proportions and Heights
2.2.6 Tactile Letters, Symbols and Braille
2.3 ALUMINUM ALLOY PRODUCTS
2.4 ANODIC COATING
2.5 ORGANIC COATING
2.6 FABRICATION AND MANUFACTURE
2.6.1 Factory Workmanship
2.6.2 Dissimilar Materials
2.7 COLOR, FINISH, AND CONTRAST
2.8 TYPEFACE
PART 3 EXECUTION
3.1 INSTALLATION
3.1.1 Anchorage
3.1.2 Protection and Cleaning
-- End of Section Table of Contents --
SECTION 10 14 00.20 Page 1
Revised By Amendment
SECTION 10 14 00.20
INTERIOR SIGNAGE
08/17
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by basic designation only.
ALUMINUM ASSOCIATION (AA)
AA DAF45 (2003; Reaffirmed 2009) Designation System for Aluminum Finishes
AA PK-1 (2015) Pink Sheets: Designations and Chemical Composition Limits for Aluminum Alloys in the Form of Castings & Ingot
AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)
AAMA 2604 (2013) Voluntary Specification, Performance Requirements and Test Procedures for High Performance Organic Coatings on Aluminum Extrusions and Panels
AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)
ANSI Z97.1 (2015) Safety Glazing Materials Used in Buildings - Safety Performance Specifications and Methods of Test
AMERICAN WELDING SOCIETY (AWS)
AWS D1.2/D1.2M (2014) Structural Welding Code - Aluminum
ASTM INTERNATIONAL (ASTM)
ASTM B209 (2014) Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate
ASTM B221 (2014) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines
SECTION 10 14 00.20 Page 2
1.2 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Detail Drawings; G
SD-03 Product Data
Installation; G
Warranty; G
SD-04 Samples
Interior Signage; G
Software; G
SD-10 Operation and Maintenance Data
Approved Manufacturer's Instructions; G
Protection and Cleaning; G
1.3 EXTRA MATERIALS
Provide 10% extra frames and extra stock of the following: Changeable message strips for sign type AA1. Provide paper inserts and one copy of the software used for produced signs and inserts after project completion and equipment necessary for removal of signage parts and pieces.
1.4 QUALITY ASSURANCE
1.4.1 Samples
Submit interior signage samples of each of the following sign types showing typical quality, workmanship and color: Directional sign, Standard Room sign, Changeable message strip sign. The samples may be installed in the work, provided each sample is identified and location recorded.
1.4.2 Detail Drawings
Submit detail drawings showing elevations of each type of sign, dimensions, details and methods of mounting or anchoring, mounting height, shape and thickness of materials, and details of construction. Include a schedule showing the location, each sign type, and message.
1.5 DELIVERY, STORAGE, AND HANDLING
Materials must be packaged to prevent damage and deterioration during shipment, handling, storage and installation. Product must be delivered to
SECTION 10 14 00.20 Page 3 the jobsite in manufacturer's original packaging and stored in a clean, dry area in accordance with manufacturer's instructions.
1.6 WARRANTY
Warrant the interior signage for a period of 2 years against defective workmanship and material. Warranties must be signed by the authorized representative of the manufacturer. Submit warranty accompanied by the document authenticating the signer as an authorized representative of the guarantor. Guarantee that the signage products and the installation are free from any defects in material and workmanship from the date of delivery.
PART 2 PRODUCTS
2.1 STANDARD PRODUCTS
Signs, plaques, directories, and dimensional letters must be the standard product of a manufacturer regularly engaged in the manufacture of such products that essentially duplicate signs that have been in satisfactory use at least 2 years prior to bid opening. Obtain signage from a single manufacturer with edges and corners of finished letterforms and graphics true and clean.
2.2 ROOM IDENTIFICATION/DIRECTIONAL SIGNAGE SYSTEM
2.2.1 Standard Room Signs
Signs must consist of acrylic plastic 0.080 inch thickness minimum conforming to ANSI Z97.1 and must conform to the following:
a. Frames must be molded acrylic, flat 1/4 inch thick.
b. End caps must be molded acrylic with square style corners.
c. Units must be frameless. Corners of signs must be squared.
2.2.2 Changeable Message Strip Signs
Changeable message strip signs must be of same construction as standard room signs to include a clear sleeve that will accept a paper or plastic insert identifying changeable text. The insert must be prepared typeset message mounted on paper card stock. Provide paper and software for creating text and symbols for computers identified by owner for Owner production of paper inserts after project completion. Furnish one suction device to assist in removing face sheet. Sliding inserts or slide knobs that slide horizontally exposing different graphic information must be provided as identified in the signage placement schedule and drawings.
2.2.3 Type of Mounting For Signs
Provide extruded aluminum brackets for hanging, projecting, and double-sided signs. Mounting for framed, hanging, and projecting signs must be by mechanical fasteners. Surface mounted signs must be mounted with countersunk mounting holes in plaques and mounting screws fabricated from materials that are not corrosive to sign material and mounting surface.
2.2.4 Graphics
Signage graphics for modular signs must conform to the following:
SECTION 10 14 00.20 Page 4
2.2.4.1 Graphic Blast Raised Copy
Background is sandblasted to a uniform depth of 1/32 inch leaving raised text and Braille. Background must be painted with polyurethane paint.
2.2.5 Character Proportions and Heights
Letters and numbers on signs conform to 36 CFR 1191.
2.2.6 Tactile Letters, Symbols and Braille
Raised letters and numbers on signs must conform to 36 CFR 1191.
2.3 BUILDING DIRECTORIES
Building directories must be lobby directories or floor directories, and must be provided with a changeable directory listing consisting of the areas, offices and personnel located within the facility. Dimensions, details, and materials of sign and message content must be as shown on the drawings.
2.3.1 Header Panel
Header panel must be acrylic with raised acrylic letters.
2.3.2 Doors
2.3.2.1 Door Glazing
Door glazing must be clear polycarbonate sheet 3/16 inch thick.
2.3.2.2 Door Construction
Extruded aluminum door frame must be of same finish as surrounding frame.
Corners must be mitered, welded, and assembled with concealed fasteners.
Hinges must be standard with the manufacturer, in finish to match frames and trim. Glazing must be set in frame with resilient glazing channels.
2.3.2.3 Door Locks
Door locks must be manufacturer's standard, and must be keyed alike.
Provide two sets of keys.
2.3.3 Fabrication
Extruded aluminum frames and trim must be assembled with corners welded and mitered to a hairline fit, with no exposed fasteners.
2.3.4 Non-Illuminated Unit
Directory must consist of a non-illuminated unit with machine or laser engraved copy in interchangeable acrylic, metal, or high-pressure plastic laminate strips. Design of unit must be as shown in the drawings.
2.3.4.1 Construction
The directory must be constructed of an aluminum 4 inch deep frame with dark bronze anodized finish. Unit must be surface mounted. Unit must have
SECTION 10 14 00.20 Page 5 a 3 inch high header lettering as shown. Unit must have a 3/8 inch face door frame with concealed hinges and locking system or other secure method. Door frame must match directory material and finish.
2.3.4.2 Message Strips
Message strips must be updatable by user. Message strips must be sized in accordance with manufacturer's standard. Letters and numbers must be provided in accordance with the drawings.
2.3 ALUMINUM ALLOY PRODUCTS
Aluminum extrusions must be at least 1/8 inch thick, and aluminum plate or sheet must be at least 0.0508 inch thick. Extrusions must conform to ASTM B221; plate and sheet must conform to ASTM B209. Where anodic coatings are specified, alloy must conform to AA PK-1 alloy designation
514.0. Exposed anodized aluminum finishes must be as shown. Welding for aluminum products must conform to AWS D1.2/D1.2M.
2.4 ANODIC COATING
Anodized finish must conform to AA DAF45 as follows:
a. Integral color anodized designation AA-M10-C22-A32, Architectural Class
0.4 to 0.7 mil.
2.5 ORGANIC COATING
Organic coating must conform to AAMA 2604, with total dry film thickness not less than 1.2 mils.
2.6 FABRICATION AND MANUFACTURE
2.6.1 Factory Workmanship
Holes for bolts and screws must be drilled or punched. Drilling and punching must produce clean, true lines and surfaces. Exposed surfaces of work must have a smooth finish and exposed riveting must be flush.
Fastenings must be concealed where practicable.
2.6.2 Dissimilar Materials
Where dissimilar metals are in contact, the surfaces will be protected to prevent galvanic or corrosive action.
2.7 COLOR, FINISH, AND CONTRAST
Color must be as indicated on drawings. Finish of all signs must be eggshell, matte, or other non-glare finish as required in handicapped-accessible buildings.
2.8 TYPEFACE
Helvetica Medium.
SECTION 10 14 00.20 Page 6
PART 3 EXECUTION
3.1 INSTALLATION
Signs must be installed plumb and true and in accordance with approved manufacturer's instructions at locations shown on the detail drawings.
Submit six copies of operating instructions outlining the step-by-step procedures required for system operation. The instructions must include simplified diagrams for the system as installed, the manufacturer's name, model number, service manual, parts list, and brief description of all equipment and their basic operating features. Each set must be permanently bound and must have a hard cover. The following identification must be inscribed on the covers: the words "OPERATING AND MAINTENANCE INSTRUCTIONS", name and location of the facility, name of the Contractor, and contract number. Mounting height and mounting location must conform to 36 CFR 1191. Required blocking must be installed. Signs on doors or other surfaces must not be installed until finishes on such surfaces have been installed. Signs installed on glass surfaces must be installed with matching blank back-up plates in accordance with manufacturer's instructions.
Do not install items that show visual evidence of biological growth.
3.1.1 Anchorage
Anchorage must be in accordance with approved manufacturer's instructions.
Anchorage not otherwise specified or shown must include slotted inserts, expansion shields, and powder-driven fasteners when approved for concrete;
toggle bolts and through bolts for masonry; machine carriage bolts for steel; lag bolts and screws for wood. Exposed anchor and fastener materials must be compatible with metal to which applied and must have matching color and finish.
a. Signs mounted to painted gypsum board surfaces must be removable for painting maintenance.
b. Mount signs mounted to lay-in ceiling grids with clip connections to ceiling tees.
c. Install signs mounted on metal surfaces with magnetic tape.
d. Install signs mounted on fabric surfaces with hook and loop tape or pin mount.
3.1.2 Protection and Cleaning
Protect the work against damage during construction. Hardware and electrical equipment must be adjusted for proper operation. Glass, frames, and other sign surfaces must be cleaned at completion of sign installation in accordance with the manufacturer's approved instructions. Submit six copies of maintenance instructions listing routine procedures, repairs, and guides.
-- End of Section --
SECTION 10 14 00.20 Page 7