Amendment_0003_-KC46_2-Bay_Hangar_-_Plans.pdf

PDF 2 MB Posted

Attached to
KC 46A Two Bay General Purpose MX Hangar Federal contract opportunity
Solicitation number
W912DS-19-R-0001
Issued by
Department of the Army Corps of Engineers Engineering District New York

About this file

Amendment 0003 -KC46 2-Bay Hangar - Plans

View the file

Other files for this federal contract opportunity

Other files attached to KC 46A Two Bay General Purpose MX Hangar, newest first.
File Type Posted
Amendment_0009.pdf PDF
Amendment_0007.pdf PDF
Amendment_0008.pdf PDF
Amendment_0008_Plan.pdf PDF
Amendment_0008_Spec.pdf PDF
hangar_site_visit_sign_in_12.27.18.pdf PDF
Amendment_0006_-_2-Bay_MX_Hangar_Plans.docx.pdf PDF
Appendix_Q_-_KC46_2-Bay_Hangar_Soil_Erosion_Plans.pdf PDF
Amendment_0006_-_2-Bay_MX_Hangar_Specs.pdf PDF
Amedment_0006.pdf PDF
Amendment_0005.pdf PDF
Amendment_0004.pdf PDF
Amendment_0003_-KC46_2-Bay_Hangar_-_Specs.pdf PDF
Amendment_0003.pdf PDF
Appendix_P_-_Site_Visit_14_NOV_2_Bay_Hanger.pdf PDF
W912DS19R0001-0002.pdf PDF
Amendment_0001.pdf PDF
Appendix_G_-_KC46_2-Bay_Hangar_CADD_Files_(Aval_After_Award).pdf PDF
Appendix_B_-_As-Built_Drawings_For_Buildings_1801_and_1823.pdf PDF
Package_2_-_KC46_-_2-Bay_Hangar_-_Specifications.pdf PDF
Package_4_-_KC46_-_2-Bay_Hangar_-_FFE.pdf PDF
Pages_from_Package_1_-_KC46_-_2-Bay_Hangar_-_Plans-1.pdf PDF
Package_3_-_KC46_-_2-Bay_Hangar_-_CID.pdf PDF
Pages_from_Package_1_-_KC46_-_2-Bay_Hangar_-_Plans_2.pdf PDF
Appendix_O_-_Hangar_Acceptance_Test_Procedures_AFCEC.pdf PDF
Appendix_F_-_USACE_Joint_Base_MDL_HazMat_Assessment_Report_5-8-18_(KM).pdf PDF
Appendix_I_-_SOO-KC-46A_Beddown.pdf PDF
Appendix_C_-_Sustainability_Checklists_and_References.pdf PDF
W912DS19R0001.pdf PDF
Appendix_N_-_KC-46A_MOB_4_Public_FEIS_ExecSumm_June_2018.pdf PDF
Appendix_M_-_Soil_Contamination_Maps.pdf PDF
Appendix_E_-_McGuire_KC-46A_Two-Bay_MX_Hangar_Geotech_Report.pdf PDF
Appendix_J_-_ATFP_Flightline_Securitypdf.pdf PDF
Appendix_B_-_As-Built_Drawings_For_Buildings_1801_and_1823.pdf PDF
Appendix_K_-_KC46_-_Apron_and_Fuel_Hydrant_Relocation.pdf PDF
Appendix_A_-SOW_Attachment_2_-_AMRS_Meter_Specifications_dated_28_January_2016.pdf PDF
Appendix_H_-_JB_MDL_-_Pavement_Evaluation_Report_North_of_1837.pdf PDF
Appendix_D_-_Hydrant_Flow_Test.pdf PDF
Appendix_L_-__McGuire_Environmental_Survey_of_B1801_and_B1823_(September_1999).pdf PDF
Show all 39

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SOIL PRESSURES:

MAXIMUM ALLOWABLE BEARING PRESSURE .................................4,000 PSF

MINIMUM ALLOWABLE BEARING PRESSURE

TO COUNTERACT SWELL................................................................... 600 PSF COEFFICIENT OF FRICTION................................................................0.44

ACTIVE EARTH PRESSURE COEFFICIENT.........................................0.31

AT-REST EARTH PRESSURE COEFFICIENT.......................................0.47

PASSIVE EARTH PRESSURE COEFFICIENT.......................................3.25

NO PASSIVE RESISTANCE IN THE UPPER 5 FEET SHOULD BE CONSIDERED IN THE DESIGN DUE TO THE POTENTIAL FOR VERTICAL TENSION CRACKING DURING PERIODS OF DRY CLIMATE, AND ONLY HALF OF THE

TOTAL AVAILABLE PASSIVE PRESSURE SHOULD BE USED IN THE DESIGN BELOW 5 FEET.

FOUNDING OF FOOTINGS AND SLABS: ON FIRM UNDISTURBED NATURAL SOILS OR APPROVED COMPACTED SOILS. FLOOR SLABS SHOULD BE UNDERLAIN BY A MINIMUM 40-MIL THICK VAPOR BARRIER, 6-INCH GRANULAR CAPILLARY WATER BARRIER, AND 18 INCHES OF COMPACTED SELECT GRANULAR FILL OVER

PROPERLY PREPARED NATURAL SOILS.

FOOTING EXCAVATIONS SHOULD BE PROBED ONCE EVERY 2-3 FEET TO A DEPTH OF 3-5 FEET TO ENSURE THERE ARE NO SOFT ZONES BELOW THE FOOTINGS, AND IF SOFT MATERIALS ARE ENCOUNTERED, THEY

SHOULD BE REMOVED AND REPLACED WITH COMPACTED STRUCTURAL FILL. SOIL REMOVAL AND

RECOMPACTION: PER GEOTECHNICAL INVESTIGATION AND CONTRACT DOCUMENTS. SOILS WORK SHALL

BE OBSERVED AND TESTED BY THE CONTRACTING OFFICER OR CONTRACTOR REPRESENTATIVE.

CONTRACTOR REPRESENTATIVE: SHALL OBSERVE FOOTINGS BEFORE PLACEMENT OF REINFORCING OR CONCRETE. FOOTING OBSERVATION AND COMPACTION REPORTS SHALL BE SENT TO THE CONTRACTING

OFFICER.

ROOF AND AREA DRAINAGE: SHALL BE DIRECTED AWAY FROM THE FOUNDATIONS.

BACKFILL: EXCAVATIONS SHALL BE PROPERLY BACKFILLED. BACKFILL FOR WALLS SHALL BE PERVIOUS MATERIAL ACCEPTABLE TO THE CONTRACTING OFFICER. DO NOT PLACE BACKFILL BEHIND WALLS BEFORE THEY HAVE ATTAINED THEIR DESIGN STRENGTH. SHORE AND PROTECT WALLS FROM LATERAL LOADS UNTIL

THE SUPPORTING MEMBERS ARE IN PLACE AND HAVE DEVELOPED SPECIFIC STRENGTHS.

FOR SITE PREPARATION, REMOVE DELETERIOUS MATERIAL SUCH AS VEGETATION; ORGANIC SOILS AND ROOT ZONES; EXISTING FILL; OR LOOSE, SOFT, FROZEN, OR OTHERWISE UNSUITABLE MATERIALS FROM

BELOW THE PROPOSED BUILDING AND PAVEMENT AREAS.

FOR ADDITIONAL SOIL INFORMATION, REFER TO THE GEOTECHNICAL REPORT LISTED IN ITEM NUMBER 1.

CENTER ALL FOOTINGS UNDER WALLS, COLUMNS OR GRID LINES, UNLESS NOTED OTHERWISE ON THE

DRAWINGS.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

REINFORCED CONCRETE

MATERIALS:

CEMENT................................................................. ASTM C 150, TYPE II AGGREGATE......................................................... ASTM C 33, CRUSHED ROCK REINFORCEMENT................................................. ASTM A 615, GRADE 60, TYPICAL ANCHOR BOLTS.................................................... ASTM A 36, HOOKED ANCHOR BOLTS

ASTM F 1554, HEADED ANCHOR BOLTS

CONCRETE STRENGTHS:

THE CONCRETE STRENGTHS SHOWN IN THE FOLLOWING TABLE ARE THE MINIMUM COMPRESSIVE

STRENGTHS AT 28 DAYS AND THE WATER/CEMENT RATIO IS THE MAXIMUM. THE SPECIFIED SLUMP IS THE MAXIMUM PRIOR TO THE ADDITION OF ADMIXTURES. CONCRETE SHALL BE STANDARD WEIGHT CONCRETE

(145 PCF).

STRENGTH AGGREGATE SLUMP WATER/CEMENT RATIO

ITEM OF CONSTRUCTION (PSI) SIZE (IN) (IN) (LB/LB)

FOUNDATIONS/SLABS-ON-GRADE

(NOT INCLUDING HANGAR SLAB) ..........................4,500 1 4 0.57

REFER TO CIVIL DRAWINGS AND SPECIFICATION 32 13 14.13 FOR HANGAR SLAB

ELEVATED SLAB.......................................................4,000 1 4 0.57

CONTINUOUS SPECIAL INSPECTION IS REQUIRED FOR DESIGN STRENGTHS EXCEEDING 2,500 PSI.

CONCRETE SHALL BE PROPORTIONED SUCH THAT THE 7-DAY STRENGTHS ARE A MINIMUM OF SEVENTY

PERCENT OF THE SPECIFIED 28-DAY STRENGTH FOR ANY CONCRETE CONSTRUCTION REQUIRING

SHORING, BRACING OR TO RECEIVE CONSTRUCTION LOADS.

FOR FOUNDATIONS AND SLAB NOT INCLUDING HANGAR SLAB OR AIRFIELD PAVEMENT:

A WATER-REDUCING ADMIXTURE CONFORMING TO ASTM C 494, USED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, MAY BE INCORPORATED IN THE CONCRETE DESIGN MIXES. A HIGH- RANGE WATER-REDUCING (HRWR) ADMIXTURE CONFORMING TO ASTM C 494, TYPE F OR G, MAY BE USED IN CONCRETE MIXES PROVIDING THE SLUMP DOES NOT EXCEED 9". AN AIR-ENTRAINING AGENT CONFORMING TO ASTM C 260 SHALL BE USED IN CONCRETE MIXES FOR THE EXTERIOR SURFACES EXPOSED TO COLD WEATHER. THE AMOUNT OF ENTRAINED AIR SHALL BE 6 PERCENT, PLUS OR MINUS 1 PERCENT BY VOLUME.

REINFORCEMENT:

A) SHOP DRAWINGS, FABRICATION AND PLACING SHALL CONFORM TO ACI 315 AND ACI 318. SHOP

DRAWINGS SHALL REVIEWED AND APPROVED BY THE CONTRACTING OFFICER BEFORE FABRICATION.

B) CAST-IN-PLACE CONCRETE (NON-PRESTRESSED) SHALL HAVE THE FOLLOWING MINIMUM CONCRETE

COVER:

CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH...........................................3"

CONCRETE EXPOSED TO EARTH OR WEATHER:

#6 BAR THROUGH #18 BAR..........................................................................................................2" #5 BAR, W31 OR D31 WIRE AND SMALLER.................................................................................1 1/2"

CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH THE GROUND:

SLABS, WALLS, JOISTS -

#14 BAR AND #18 BAR........................................................................................................1 1/2" #11 BAR AND SMALLER.........................................................................................................3/4"

BEAMS, COLUMNS -

PRIMARY REINFORCEMENT TIES, STIRRUPS, SPIRALS................................................1 1/2"

C) CHAIRS, SPACERS AND SAND PLATES: AS REQUIRED TO MAINTAIN CONCRETE COVER.

1.

2.

3.

4.

5.

6.

CONSTRUCTION JOINTS

ALL CONSTRUCTION JOINTS SHALL BE CONSTRUCTED IN ACCORDANCE WITH IBC CODE SECTION 1906.4 AND THE

TYPICAL CONSTRUCTION JOINT DETAILS SHOWN ON THE STRUCTURAL DRAWINGS.

ALL SURFACES OF CONSTRUCTION JOINTS SHALL BE CLEANED TO REMOVE DUST, CHIPS, OR OTHER FOREIGN

MATTER PRIOR TO PLACING ADJACENT CONCRETE.

THE CONTRACTOR SHALL SUBMIT THE PROPOSED LOCATIONS OF CONSTRUCTION JOINTS TO THE CONTRACTING

OFFICER BEFORE STARTING CONSTRUCTION.

CONSTRUCTION JOINTS SHALL BE SHORED UNTIL JOINT HAS CURED.

1.

2.

3.

4.

D) VERTICAL REINFORCEMENT: SHALL BE DOWELED TO SUPPORTING MEMBERS WITH THE SAME SIZE AND

SPACING OF REINFORCEMENT AS SHOWN ON THE DRAWINGS AND IN THE GENERAL NOTES.

E) HORIZONTAL REINFORCEMENT: ALL BARS ENDING AT THE FACE OF A WALL, COLUMN OR BEAM SHALL EXTEND TO WITHIN 2" OF THE FACE AND HAVE A 90 DEGREE HOOK UNLESS OTHERWISE SHOWN.

F) SPACING: CLEAR DISTANCE BETWEEN PARALLEL REINFORCEMENT OR PARALLEL REINFORCING BARS BUNDLED IN CONTACT TO ACT AS A UNIT IN A LAYER SHALL NOT BE LESS THAN 1-1/2 TIMES THE NOMINAL DIAMETER OF THE REINFORCEMENTS OR 1-1/3 TIMES THE MAXIMUM SIZE AGGREGATE, NOR LESS THAN 1-1/2".

NORMAL DIAMETER FOR A UNIT OF BUNDLED BARS SHALL BE THE EQUIVALENT DIAMETER OF THE COMBINED

AREAS OF THE BARS BUNDLED.

G) TACK WELDING, WELDING, HEATING OR CUTTING OF BARS: NOT PERMITTED, UNLESS NOTED

OTHERWISE.

H) SLAB CORNERS: PROVIDE (2) - #4 x 4'-0" BARS AT RE-ENTRANT CORNERS AND EACH CORNER OF

RECTANGULAR HOLES IN SLABS. PLACE BARS DIAGONALLY AS SHOWN ON E9/S-501.

I) SPLICES (LAPS), UNLESS NOTED OTHERWISE:

i) CONCRETE LAP SPLICE PER S-602, FOR TENSION LAP SPLICE LENGTHS.

ii) IN NO CASE SHALL LAPS BE LESS THAN 24 INCHES LONG.

iii) STAGGER CONTINUOUS FOOTING BOTTOM SPLICES AT LEAST 6'-0" FROM SPLICES IN OTHER BOTTOM

REINFORCEMENT; STAGGER SPLICES FOR TOP REINFORCEMENT SIMILARLY.

iv) INDIVIDUAL SPLICES OF BARS IN A BUNDLE SHALL BE STAGGERED AT LEAST 87 EQUIVALENT BAR

DIAMETERS FOR BOTTOM BUNDLES AND 113 EQUIVALENT BAR DIAMETERS FOR TOP BUNDLES, WHERE THE EQUIVALENT DIAMETER IS BASED UPON THE COMBINED AREAS OF THE BARS BUNDLED. LAP LENGTHS FOR BARS IN BUNDLES OF 4 OR MORE, BARS SHALL BE INCREASED AN ADDITIONAL 11

PERCENT.

v) ALL LAP SPLICES ARE CLASS B UNLESS OTHERWISE NOTED ON PLANS.

ANCHOR BOLTS, DOWELS AND HOLD-DOWN ANCHORS: SECURELY HELD IN PLACE PRIOR TO FOUNDATION

INSPECTION BY THE SPECIAL INSPECTOR AND OBSERVATION BY THE CONTRACTING OFFICER.

PIPES, SLEEVES AND DUCTS: NOT TO BE PLACED IN WALLS, BEAMS, SLABS, FOOTINGS OR COLUMNS UNLESS

SPECIFICALLY DETAILED.

CHAMFER: 3/4 INCH ON EXPOSED CORNERS.

ADMIXTURES: REVIEWED BY CONTRACTING OFFICER, NO CALCIUM CHLORIDE.

CONSTRUCTION JOINTS: HEAVY SANDBLAST (1/4 INCH AMPLITUDE MINIMUM) AND THOROUGHLY CLEAN ALL CONCRETE SURFACES TO RECEIVE NEW CONCRETE. LOCATION OF JOINTS TO BE REVIEWED BY THE CONTRACTING

OFFICER. WAIT 48 HOURS BETWEEN POURS.

SLAB-ON-GRADE JOINTS: LOCATION OF ALL CONSTRUCTION, CONTROL AND WEAKENED PLANE JOINTS NOT SPECIFICALLY INDICATED ON THE DRAWINGS SHALL BE REVIEWED BY THE CONTRACTING OFFICER PRIOR TO THE

PLACING OF REINFORCEMENT.

ACTUAL DIMENSIONS: SLAB, WALL, BEAM AND COLUMN DIMENSIONS SHOWN ARE ACTUAL DIMENSIONS NOT

NOMINAL DIMENSIONS (I.E., A 4-INCH SLAB IS 4 INCHES THICK, NOT 3-1/2 INCHES.)

CONCRETE CURING: SEE SPECIFICATIONS.

BOLTS IN CONCRETE: MINIMUM EMBEDMENT SHALL BE PER IBC TABLE 1911.2, BUT NO LESS THAN 7 INCHES

UNLESS NOTED OTHERWISE.

8.

9.

10.

11.

12.

13.

14.

15.

16.

POST-INSTALLED CONCRETE ANCHORS

UNLESS NOTED OTHERWISE, EXPANSION BOLTS IN CONCRETE SHALL BE AS A MINIMUM 5/8" DIAMETER x 4" EMBEDMENT WITH ALLOWABLE VALUES EQUAL TO OR EXCEEDING 4,000 LB TENSION . UNLESS NOTED OTHERWISE, ALL EPOXY ANCHORS SHALL BE AS A MINIMUM 5/8" DIAMETER WITH 6" EMBEDMENT WITH ALLOWABLE VALUES EQUAL TO OR EXCEEDING 21,306 LBS TENSION AND 9,375 SHEAR (NOMINAL STRENGTH AS

GOVERNED BY STEEL DESIGN PER ESR REPORT. INSTALL EXPANSION AND EPOXY ANCHORS PER

MANUFACTURER'S RECOMMENDATIONS. LARGER ANCHORS SHALL BE USED IF REQUIRED BY THE CONTRACTING

OFFICER.

THE USE OF EXPANSION ANCHORS OR EPOXY ANCHORS SHALL BE APPROVED BY THE CONTRACTING OFFICER

PRIOR TO USE.

1.

2.

MASONRY

SPECIAL INSPECTION SHALL BE REQUIRED FOR REINFORCED HOLLOW UNIT MASONRY.

MASONRY WALL ASSEMBLY STRENGTH, F'm = 1,500 PSI MINIMUM.

MATERIALS:

CONCRETE BLOCK..................................................ASTM C 90, TYPE 1, LOAD BEARING 1,900 PSI BLOCK WITH BOND

BEAM UNITS AT HORIZONTAL REINFORCING, DRY UNITS, YARD CURE

28 DAYS.

MORTAR...................................................................ASTM C 270, ASTM C 7810, TYPE S (DO NOT USE MASONRY CEMENT).

GROUT......................................................................ASTM C 476, ASTM C 1019. USE 2,000 PSI MIN AT 28 DAYS OR

EQUIVALENT TO BLOCK STRENGTH WHICHEVER IS GREATER WITH

SIKA GROUTED OR EQUAL, 8-10 IN SLUMP.

REINFORCEMENT....................................................ASTM A 615, GRADE 60, TYPICAL.

ASTM A 706, GRADE 60, FOR WELDED REINFORCEMENT BARS.

ANCHOR BOLTS.......................................................ASTM A 36, HOOKED ANCHOR BOLTS.

ASTM F1554, HEADED ANCHOR BOLTS.

EPOXY OR EXPANSION ANCHORS.........................ICC ES APPROVED FOR GROUT FILLED CONCRETE MASONRY.

BLOCK LAYUP: RUNNING BOND, CONCAVE COMPRESSED JOINTS. USE OPEN END UNITS AT STACKED BOND

PATTERN.

1.

2.

3.

4.

REINFORCING LAP SPLICE LENGTHS

BAR

SIZE

BAR

DIA.

(IN)

1 BAR CELL 2 BAR CELL

MASONRY F'm - 1,500 PSI

8"

CMU

12"

CMU

8"

CMU

12"

CMU

24" 24" 24" 24"#3 3/8 25" 25" 31" 31"#4 1/2 31" 31" 48" 48"#5 5/8 57" 52" 98" 98"#6 3/4 79" 61" 133" 133"#7 7/8

112" 75" 186" 186"#8 1

NOTES:

1. TYPICAL UNLESS OTHERWISE NOTED.

2. FOR F'm = 2,000 PSI, REDUCE LAP LENGTHS BY 15 PERCENT. MINIMUM LENGTH SHALL BE > 24"

GROUTING:

A) ALL CELLS WITH REINFORCING SHALL BE FILLED WITH GROUT OR AS INDICATED ON THE DRAWINGS.

B) CONSOLIDATION: AT TIME OF PLACEMENT BY MECHANICAL VIBRATION AND THEN RECONSOLIDATED

BEFORE PLASTICITY IS LOST.

C) POURS OVER 5 FEET: PROVIDE CLEANOUTS IN BOTTOM COURSE AT VERTICAL REINFORCEMENT.

SPECIAL INSPECTION REQUIRED.

D) HORIZONTAL CONSTRUCTION JOINTS: FORMED BY STOPPING THE GROUT POUR NOT LESS THAN 1/2

INCH BELOW THE TOP OF THE UPPERMOST UNITS GROUTED. HORIZONTAL REINFORCING SHALL BE

FULLY EMBEDDED IN GROUT.

E) GROUT SHALL BE PLACED IN CONTINUOUS POUR IN GROUT LIFTS NOT EXCEEDING 5 FEET.

PROVIDE A MINIMUM OF 1/2 INCH CLEAR BETWEEN MAIN REINFORCING AND MASONRY UNITS.

DETERMINE COMPLIANCE WITH COMPRESSIVE STRENGTH USING EITHER THE UNIT STRENGTH METHOD PER CODE SECTION 2105.3.4 OR PRISM TESTING PER CODE SECTION 2105.3.2 OR 2105.3.3.

REINFORCING CONGESTION: KNOCK OUT BLOCKS TO BE USED TO FACILITATE CONSTRUCTION.

VERTICAL CONTROL JOINTS SHALL BE LOCATED MAXIMUM 24 FEET APART; AT MAXIMUM OF 1/2 CONTROL JOINT SPACING FROM CORNERS (NO MORE THAN 12 FEET FROM CORNERS); AT CHANGES IN WALL HEIGHT;

BETWEEN MAIN AND INTERSECTING WALL; AT PILASTERS AND CHANGES IN WALL THICKNESS.

REINFORCEMENT:

A) VERTICAL: ONE PIECE, NO SPLICES, CENTERED IN THE WALL UNLESS SPECIFICALLY DETAILED

OTHERWISE. PROVIDE VERTICAL SUPPORT SPACERS AT 200 REINFORCEMENT DIAMETERS MAXIMUM.

DOWEL REINFORCEMENT TO SUPPORT MEMBERS WITH SAME SIZE AND SPACING O REINFORCEMENT AS SHOWN ON THE DRAWINGS. THE CONTRACTOR HAS THE OPTION TO USE ADDITIONAL LAP SPLICES FOR THE PLACEMENT OF THE VERTICAL REINFORCING. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE SHOP DRAWINGS FOR REVIEW, SHOWING LOCATIONS OF ALL REINFORCING STEEL, LAP

SPLICE LENGTHS AND LOCATIONS. THE SPECIAL INSPECTOR SHALL PERFORM CONTINUOUS AND

PERIODIC SPECIAL INSPECTIONS PER THE CODE.

B) SPLICE (LAPS): SEE TABLE BELOW OR 24 INCHES, WHICHEVER IS GREATER, EPOXY-COATED BARS

SHALL HAVE THEIR LAP LENGTHS 50% GREATER THAN THOSE SPECIFIED BELOW.

REINFORCING LAP SPLICE TABLE:

5.

6.

7.

8.

9.

10.

11.

STRUCTURAL STEEL

CODES:

AISC SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION FOR STRUCTURAL STEEL FOR BUILDINGS; STEEL CONSTRUCTION MANUAL (FOURTEENTH EDITION); STRUCTURAL WELDING CODE AWS

D1.1 AND D1.4.

IDENTIFICATION:

STEEL SHAPES SHALL BE IDENTIFIED WITH MILL IDENTIFICATION MARKS IN CONFORMANCE WITH REQUIRED

ASTM.

MATERIALS:

STRUCTURAL SHAPES

WIDE FLANGE........................................ ASTM A 992GRADE 50

CHANNELS............................................. ASTM A36 GRADE 36

ANGLES, PLATES AND RODS............... ASTM A36 GRADE 36

HSS SHAPES (TUBES).......................... ASTM A 500GRADE B, Fy = 46 KSI PIPE....................................................... ASTM A 53 GRADE B, TYPE E OR S

MACHINE BOLTS................................................... ASTM A 307

NUTS...................................................................... ASTM A 563GRADE A, HEX

HIGH STRENGTH BOLTS...................................... ASTM A 325

NUTS...................................................................... ASTM A 563GRADE CL, HEAVY HEX NON-SHRINK GROUT............................................ ASTM C 1107 NON-METALLIC, 7,000 PSI STRENGTH ANCHOR BOLTS.................................................... ASTM F 1554 GRADE 36

WELDING: ALL WELDING SHALL BE IN CONFORMANCE WITH AWS D1.1.

A) ELECTRODES.............................................. CLASS E-70XX SERIES, LOW HYDROGEN, NOTCH TOUGHNESS

OF 20 FT/LBS AT MINUS 20 DEGREES FAHRENHEIT

B) WELDERS.................................................... CERTIFIED.

C) GROOVE AND BUTT WELDS...................... COMPLETE PENETRATION (CP), UNO.

D) FILLET WELDS.............................................SIZES SPECIFIED ARE MINIMUM STRUCTURAL WELDS.

INCREASE AS REQUIRED BY ASD TABLE J2.4.

E) FIELD WELDING.......................................... MAY BE REQUIRED TO FACILITATE CONSTRUCTION.

F) TERMINATION............................................. WELDS TERMINATING AT ENDS OR SIDES, WHEREVER

PRACTICABLE, SHALL BE RETURNED CONTINUOUSLY AROUND

CORNERS A DISTANCE OF 2 TIMES THE NORMAL SIZE OF THE

WELD PER ASD SECTION J2.2.B.

G) LENGTHS..................................................... WHERE LENGTH IS NOT SPECIFIED, IT SHALL BE TAKEN AS

THE FULL LENGTH OF THE JOINT.

THE CONTRACTOR SHALL SUBMIT A WELDING PROCEDURE SPECIFICATION (WPS), DEVELOPED BY THE FABRICATOR, IN CONFORMANCE WITH AWS 1.1 FOR REVIEW BY THE CONTRACTING OFFICER. ALL WELDS SHALL BE PRE-QUALIFIED PER AWS D1.1. THE WPS SHALL INCLUDE THE WELDING PARAMETERS

RECOMMENDED BY THE ELECTRODE MANUFACTURER.

SHOP DRAWINGS: REVIEWED BY THE CONTRACTING OFFICER BEFORE FABRICATION.

1.

2.

3.

4.

5.

6.

US Army Corps of Engineers ®

SHEET

IDENTIFICATION

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

D . E

LL

ED

G E

S-002

G

EN

ER

AL

S

TR

U C

TU

R

AL

N

O

TE

S

JO

IN

T

BA

SE

M

C G

U

IR

E/ D

IX

/L

AK

EH

U R

ST

, N

EW

J

ER

SE

Y

F

ED

ER

AL

P

LA

ZA

N E W

Y O

R K, N Y

C . T

R

AN

C . T

R

AN

A.

M

AG

IN

N

IS

SE

PT

EM

BE

R

RTA SUBMITTAL

KC

-4

6A T

W O

B

AY

G

EN

ER

AL

P U

R P O

SE

M

X H

AN

G

AR

BU

IL

D

IN

G

PR

O

JE

C T

N U

M

BE

R : P

TF

L1

N E W

Y O

R K

D

IS

TR

IC

T

R

EV

IS

ED

N

O

TE

D

EC

e3enmrt3 Polygon

D E

F

G

H

I

J

7 1310 1611 158 9

B1 S-203

D1 S-205

A1 S-206

16' - 5" 18' - 7" 15' - 11" 18' - 0" 15' - 4" 24' - 0" 23' - 4"

C1 C1 C1 C1 C1 C1 C1 C1C1

C5 C5 C5 C5 C5 C5 C5 C5 C5

C5

C3

C5

C5

C5

CF3.5

CF3.5

T.O.

FTG=-4'-0"

CF3.5

CF3.5

CF3.5

CF3.5

17.1

NOTE 4

NOTE 4

NOTE 4

NOTE 4

CJ CJ

CJ CJ

CJ CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

31' - 0"

CF10

T.O.

FTG=-4'-0"

CF10

T.O.

FTG=-4'-0"

CF24

T.O.

FTG=-4'-0"

CF24

T.O.

FTG=-4'-0"

CF3.5

T.O.

FTG=-4'-0"

CF3.5

T.O.

FTG=-4'-0"

CF3.5

T.O.

FTG=-4'-0"

CF3.5

CF3.5

T.O.

FTG=-4'-0"

CF3.5

T.O.

FTG=-4'-0"

CF3.5

T.O.

FTG=-4'-0"

CF3.5

T.O.

FTG=-4'-0"

CF3.5

T.O.

FTG=-4'-0"

CF3.5

T.O.

FTG=-4'-0"

CF3.5

T.O.

FTG=-4'-0"

2'

- 0

7'

- 4

20' - 0"15' - 4" 20' - 0" 15' - 4"

42' - 0"42' - 0"

/8

118.36° 118.36°

CJ

CJ

CJ

CJ CJ CJ

CJCJCJ

CJ CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ CJ

CJ

CJ

CJ

CJ

CJ

CJ CJ

CJ

2 2

E6

S-505 SIM.

E6

S-505 SIM.

A6 S-503

FOR GENERAL STRUCTURAL NOTES, REFER TO S-001, S-002, AND S-003.

FOR TYPICAL CONCRETE, MASONRY, STEEL DETAILS, REFER TO S-500 SERIES

SHEETS. FOR SCHEDULES, REFER TO S-600 SERIES SHEETS.

ELEVATION 0'-0" = CIVIL ELEVATION 120.85.

SLAB ON GRADE SHALL BE 6" THICK CONCRETE REINFORCED WITH #4@18" O.C.

UNO. REINFORCEMENT SHALL BE PLACED 2" BELOW TOP OF SLAB. TOP OF

SLAB ON GRADE ELEVATION = 0'-0", TYP. WHERE SLAB SLOPES TO DRAIN, THE

HIGH POINTS SHALL BE AT ELEVATION 0'-0".

REFER TO CIVIL DRAWINGS FOR HANGAR PAVEMENT INFORMATION AND

JACKING POINTS AND DESIGN.

SHEET NOTES:

1.

2.

3.

4.

5.

FOOTING DESIGNATION. REFER TO FOOTING SCHEDULE ON S-602 FOR INFORMATION.

CONTINUOUS FOOTING DESIGNATION. REFER TO CONTINUOUS FOOTING SCHEDULE

ON S-602 FOR INFORMATION.

CONTRACTION JOINT OR CONSTRUCTION JOINT. SEE E1 & E3/S-501 FOR DETAILS.

COLUMN DESIGNATION. SEE COLUMN SCHEDULE ON S-602 FOR INFORMATION.

8" CONCRETE MASONRY WALL WITH #5 @24" O.C VERTICAL BARS. ALL CELLS WITH

REINFORCING SHALL BE FILLED WITH GROUT. TOP OF WALL ELEVATION = 12'-0" UNO.

8" CONCRETE MASONRY WALL WITH #8 @16" O.C VERTICAL BARS. ALL CELLS WITH

REINFORCING SHALL BE FILLED WITH GROUT. TOP OF WALL ELEVATION = 26'-0" UNO.

LEGEND

FX

CFX

--CJ--

CX

NOT USED.

INDICATES 9" THICK CONCRETE SLAB

REINFORCED WITH #4@12" O.C. T&B. TOP

OF SLAB EL. = 0'-0". ISOLATION JOINT

SHALL BE PLACE AROUND PERIMETER OF

9" SLAB.

SHEET KEYNOTES:

1.

2.

US Army Corps of Engineers ®

SHEET

IDENTIFICATION

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

D . E

LL

ED

G E

S-103

ST

R

U C

TU

R

AL

F

O U

N D

AT

IO

N P

LA

N

-A R

EA

B

JO

IN

T

BA

SE

M

C G

U

IR

E/ D

IX

/L

AK

EH

U R

ST

, N

EW

J

ER

SE

Y

F

ED

ER

AL

P

LA

ZA

N E W

Y O

R K, N Y

C . T

R

AN

C . T

R

AN

A.

M

AG

IN

N

IS

SE

PT

EM

BE

R

RTA SUBMITTAL

KC

-4

6A T

W O

B

AY

G

EN

ER

AL

P U

R P O

SE

M

X H

AN

G

AR

BU

IL

D

IN

G

PR

O

JE

C T

N U

M

BE

R : P

TF

L1

N E W

Y O

R K

D

IS

TR

IC

T

1/8" = 1'-0"A1 STRUCTURAL FOUNDATION PLAN - AREA B

A

KEY PLAN

B

E

G

F

C

D

0' 2' 4' 8' 16'

NORTH

AD

D

ED

U M

IN

R

ES

PO

N

SE

T

O B

ID

D

ER

IN

Q U

IR

IE

S

D

EC

F

G

H

I

J

242221201918 22' - 7" 21' - 2" 23' - 8" 22' - 5"

A1 S-202

CF5.5

C1

C5

C6

C6

C6

C4

C4

CF13

T.O.

FTG=-4'-0"

CF3.5

T.O.

FTG=-4'-0"

17.1

17.1

18.1

C5

27' - 2"

2'-0"x2'-0"x2'-0"

SUMP PIT

2' - 0"

7'

- 2

EQ.

EQ.

CF13

T.O.

FTG=-4'-0"

CF3.5

T.O.

FTG=-4'-0"

CF10

T.O.

FTG=-4'-0"

CF10

T.O.

FTG=-4'-0"

CF3.5

T.O.

FTG=-4'-0"

5' - 11" 5"

2' - 9" 3' - 2"

1'

- 5

E6 S-503

E1 S-503

E3 S-503

E3 S-503

SIM.

1' - 3" 1' - 5" 1' - 5"1' - 5"

1'

- 2

8'

- 1

A7 S-505

FOR GENERAL STRUCTURAL NOTES, REFER TO S-001, S-002, AND S-003.

FOR TYPICAL CONCRETE, MASONRY, STEEL DETAILS, REFER TO S-500 SERIES

SHEETS. FOR SCHEDULES, REFER TO S-600 SERIES SHEETS.

ELEVATION 0'-0" = CIVIL ELEVATION 120.85.

SLAB ON GRADE SHALL BE 6" THICK CONCRETE REINFORCED WITH #4@18" O.C.

UNO. REINFORCEMENT SHALL BE PLACED 2" BELOW TOP OF SLAB. TOP OF

SLAB ON GRADE ELEVATION = 0'-0", TYP. WHERE SLAB SLOPES TO DRAIN, THE

HIGH POINTS SHALL BE AT ELEVATION 0'-0".

REFER TO CIVIL DRAWINGS FOR HANGAR PAVEMENT INFORMATION AND

JACKING POINTS AND DESIGN.

SHEET NOTES:

1.

2.

3.

4.

5.

FOOTING DESIGNATION. REFER TO FOOTING SCHEDULE ON S-602 FOR INFORMATION.

CONTINUOUS FOOTING DESIGNATION. REFER TO CONTINUOUS FOOTING SCHEDULE

ON S-602 FOR INFORMATION.

CONTRACTION JOINT OR CONSTRUCTION JOINT. SEE E1 & E3/S-501 FOR DETAILS.

COLUMN DESIGNATION. SEE COLUMN SCHEDULE ON S-602 FOR INFORMATION.

8" CONCRETE MASONRY WALL WITH #5 @24" O.C VERTICAL BARS. ALL CELLS WITH

REINFORCING SHALL BE FILLED WITH GROUT. TOP OF WALL ELEVATION = 12'-0" UNO.

8" CONCRETE MASONRY WALL WITH #8 @16" O.C VERTICAL BARS. ALL CELLS WITH

REINFORCING SHALL BE FILLED WITH GROUT. TOP OF WALL ELEVATION = 26'-0" UNO.

LEGEND

FX

CFX

--CJ--

CX

US Army Corps of Engineers ®

SHEET

IDENTIFICATION

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

D . E

LL

ED

G E

S-104

ST

R

U C

TU

R

A L F

O U

N D

AT

IO

N P

LA

N

-A R

EA

C

J O

IN

T B A

SE

M

C G

U

IR

E/ D

IX

/L

AK

EH

U R

ST

, N

EW

J

ER

SE

Y

F

E D

ER

AL

P

LA

ZA

N

EW

Y O

R K, N Y

C . T

R

AN

C . T

R

AN

A.

M

AG

IN

N

IS

SE

PT

EM

BE

R

RTA SUBMITTAL

KC

-4

6A T

W O

B

AY

G

EN

ER

AL

P U

R

PO

S E M

X H

A N G

AR

BU

I L D

IN

G

PR

O J E

C T

N U

M

BE

R : P

TF

L1

6 3

N

EW

Y O

R K

D

IS

TR

IC

T

1/8" = 1'-0"A1 STRUCTURAL FOUNDATION PLAN - AREA C

A

KEY PLAN

B

E

G

F

C

D

NORTH

0' 2' 4' 8' 16'

AD

D

ED

U M

IN

R

ES

PO

N

SE

T

O B

ID

D

ER

IN

Q U

IR

IE

S

D

EC

J

K

L

M

N

O

P 2422212019 23

4'

- 8

4' - 10"

A1 S-202

CF13

T.O.

FTG=-4'-0"

C4

C4

C4

C4

C4

C4

C6

C6

C4 A1

S-208 17.1 A8

S-211

F18 T.O.

FTG=-4'-0"

6' - 7"

6'

- 8

E3 S-503

E6 S-503

E1 S-503

FOR GENERAL STRUCTURAL NOTES, REFER TO S-001, S-002, AND S-003.

FOR TYPICAL CONCRETE, MASONRY, STEEL DETAILS, REFER TO S-500 SERIES

SHEETS. FOR SCHEDULES, REFER TO S-600 SERIES SHEETS.

ELEVATION 0'-0" = CIVIL ELEVATION 120.85.

SLAB ON GRADE SHALL BE 6" THICK CONCRETE REINFORCED WITH #4@18" O.C.

UNO. REINFORCEMENT SHALL BE PLACED 2" BELOW TOP OF SLAB. TOP OF

SLAB ON GRADE ELEVATION = 0'-0", TYP. WHERE SLAB SLOPES TO DRAIN, THE

HIGH POINTS SHALL BE AT ELEVATION 0'-0".

REFER TO CIVIL DRAWINGS FOR HANGAR PAVEMENT INFORMATION AND

JACKING POINTS AND DESIGN.

SHEET NOTES:

1.

2.

3.

4.

5.

FOOTING DESIGNATION. REFER TO FOOTING SCHEDULE ON S-602 FOR INFORMATION.

CONTINUOUS FOOTING DESIGNATION. REFER TO CONTINUOUS FOOTING SCHEDULE

ON S-602 FOR INFORMATION.

CONTRACTION JOINT OR CONSTRUCTION JOINT. SEE E1 & E3/S-501 FOR DETAILS.

COLUMN DESIGNATION. SEE COLUMN SCHEDULE ON S-602 FOR INFORMATION.

8" CONCRETE MASONRY WALL WITH #5 @24" O.C VERTICAL BARS. ALL CELLS WITH

REINFORCING SHALL BE FILLED WITH GROUT. TOP OF WALL ELEVATION = 12'-0" UNO.

8" CONCRETE MASONRY WALL WITH #8 @16" O.C VERTICAL BARS. ALL CELLS WITH

REINFORCING SHALL BE FILLED WITH GROUT. TOP OF WALL ELEVATION = 26'-0" UNO.

LEGEND

FX

CFX

--CJ--

CX

NOT USED

NOT USED

5'-0"x5'-0"x6" CONCRETE STOOP WITH #3 @

18" O.C. PLACE REINFORCING 1.5" FROM TOP

OF CONCRETE. DOWEL REBAR 18" O.C. IN

STOOP INTO HANGAR FOUNDATION. DOWEL

EMBEDMENT DEPTH= 6 INCHES.

(2) HSS12x6x3/8 POSTS FOR JAMB SUPPORT.

TOP OF POSTS AT CATWALK LEVEL.

ADJUSTABLE AT TOP TO ALLOW PLUMBING.

COORDINATE EXACT LOCATIONS WITH DOOR

MANUFACTURER.

SHEET KEYNOTES:

1.

2.

3.

4.

US Army Corps of Engineers ®

SHEET

IDENTIFICATION

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

D . E

LL

ED

G E

S-105

ST

R

U C

TU

R

AL

F

O U

N D

AT

IO

N P

LA

N

-A R

EA

D

JO

IN

T

BA

SE

M

C G

U

IR

E/ D

IX

/L

AK

EH

U R

ST

, N

EW

J

ER

SE

Y

F

ED

ER

AL

P

LA

ZA

N E W

Y O

R K, N Y

C . T

R

AN

C . T

R

AN

A.

M

AG

IN

N

IS

SE

PT

EM

BE

R

RTA SUBMITTAL

KC

-4

6A T

W O

B

AY

G

EN

ER

AL

P U

R P O

SE

M

X H

AN

G

AR

BU

IL

D

IN

G

PR

O

JE

C T

N U

M

BE

R : P

TF

L1

N E W

Y O

R K

D

IS

TR

IC

T

1/8" = 1'-0"A1 STRUCTURAL FOUNDATION PLAN - AREA D

A

KEY PLAN

B

E

G

F

C

D

0' 2' 4' 8' 16'

NORTH

AD

D

ED

U M

IN

R

ES

PO

N

SE

T

O B

ID

D

ER

IN

Q U

IR

IE

S

D

EC

e3enmrt3 Polygon

L

M

N

O

P

7 1310 1611 12 14 158 9

A1 S-206

C5

C5

C5

C5

C5

C5

C5

C4

C5

C4

C3

CF24

T.O.

FTG=-4'-0"

17.1

31' - 0"

F25 T.O.

FTG=-4'-0"

8' - 0"

4' - 6" 4' - 6"

A6 S-503

A6 S-503

A6 S-503

FOR GENERAL STRUCTURAL NOTES, REFER TO S-001, S-002, AND S-003.

FOR TYPICAL CONCRETE, MASONRY, STEEL DETAILS, REFER TO S-500 SERIES

SHEETS. FOR SCHEDULES, REFER TO S-600 SERIES SHEETS.

ELEVATION 0'-0" = CIVIL ELEVATION 120.85.

SLAB ON GRADE SHALL BE 6" THICK CONCRETE REINFORCED WITH #4@18" O.C.

UNO. REINFORCEMENT SHALL BE PLACED 2" BELOW TOP OF SLAB. TOP OF

SLAB ON GRADE ELEVATION = 0'-0", TYP. WHERE SLAB SLOPES TO DRAIN, THE

HIGH POINTS SHALL BE AT ELEVATION 0'-0".

REFER TO CIVIL DRAWINGS FOR HANGAR PAVEMENT INFORMATION AND

JACKING POINTS AND DESIGN.

SHEET NOTES:

1.

2.

3.

4.

5.

FOOTING DESIGNATION. REFER TO FOOTING SCHEDULE ON S-602 FOR INFORMATION.

CONTINUOUS FOOTING DESIGNATION. REFER TO CONTINUOUS FOOTING SCHEDULE

ON S-602 FOR INFORMATION.

CONTRACTION JOINT OR CONSTRUCTION JOINT. SEE E1 & E3/S-501 FOR DETAILS.

COLUMN DESIGNATION. SEE COLUMN SCHEDULE ON S-602 FOR INFORMATION.

8" CONCRETE MASONRY WALL WITH #5 @24" O.C VERTICAL BARS. ALL CELLS WITH

REINFORCING SHALL BE FILLED WITH GROUT. TOP OF WALL ELEVATION = 12'-0" UNO.

8" CONCRETE MASONRY WALL WITH #8 @16" O.C VERTICAL BARS. ALL CELLS WITH

REINFORCING SHALL BE FILLED WITH GROUT. TOP OF WALL ELEVATION = 26'-0" UNO.

LEGEND

FX

CFX

--CJ--

CX

NOT USED

NOT USED

NOT USED

(2) HSS12x6x3/8 POSTS FOR JAMB SUPPORT.

TOP OF POSTS AT CATWALK LEVEL.

ADJUSTABLE AT TOP TO ALLOW PLUMBING.

COORDINATE EXACT LOCATIONS WITH DOOR

MANUFACTURER.

SHEET KEYNOTES:

1.

2.

3.

4.

US Army Corps of Engineers ®

SHEET

IDENTIFICATION

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

D . E

LL

ED

G E

S-106

ST

R

U C

TU

R

AL

F

O U

N D

AT

IO

N P

LA

N

-A R

EA

E

JO

IN

T

BA

SE

M

C G

U

IR

E/ D

IX

/L

AK

EH

U R

ST

, N

EW

J

ER

SE

Y

F

ED

ER

AL

P

LA

ZA

N E W

Y O

R K, N Y

C . T

R

AN

C . T

R

AN

A.

M

AG

IN

N

IS

SE

PT

EM

BE

R

RTA SUBMITTAL

KC

-4

6A T

W O

B

AY

G

EN

ER

AL

P U

R P O

SE

M

X H

AN

G

AR

BU

IL

D

IN

G

PR

O

JE

C T

N U

M

BE

R : P

TF

L1

N E W

Y O

R K

D

IS

TR

IC

T

A

KEY PLAN

B

E

G

F

C

D

1/8" = 1'-0"A1 STRUCTURAL FOUNDATION PLAN - AREA E

NORTH

0' 2' 4' 8' 16'

AD

D

ED

U M

IN

R

ES

PO

N

SE

T

O B

ID

D

ER

IN

Q U

IR

IE

S

D

EC

L

M

N

O

P

1 2 3 4 5 6 7

4'

- 8

4' - 10"

A1 S-201

CF13

T.O.

FTG=-4'-0"

A1 S-207

30' - 4"

C4

C4

C4

C4

C4

C6

C4

C4

C6

F18 T.O.

FTG=-4'-0"

6' - 7"

6'

- 8

17' - 7" 23' - 8" 21' - 2" 22' - 7"

E1 S-503

E6 S-503

E3 S-503

FOR GENERAL STRUCTURAL NOTES, REFER TO S-001, S-002, AND S-003.

FOR TYPICAL CONCRETE, MASONRY, STEEL DETAILS, REFER TO S-500 SERIES

SHEETS. FOR SCHEDULES, REFER TO S-600 SERIES SHEETS.

ELEVATION 0'-0" = CIVIL ELEVATION 120.85.

SLAB ON GRADE SHALL BE 6" THICK CONCRETE REINFORCED WITH #4@18" O.C.

UNO. REINFORCEMENT SHALL BE PLACED 2" BELOW TOP OF SLAB. TOP OF

SLAB ON GRADE ELEVATION = 0'-0", TYP. WHERE SLAB SLOPES TO DRAIN, THE

HIGH POINTS SHALL BE AT ELEVATION 0'-0".

REFER TO CIVIL DRAWINGS FOR HANGAR PAVEMENT INFORMATION AND

JACKING POINTS AND DESIGN.

SHEET NOTES:

1.

2.

3.

4.

5.

FOOTING DESIGNATION. REFER TO FOOTING SCHEDULE ON S-602 FOR INFORMATION.

CONTINUOUS FOOTING DESIGNATION. REFER TO CONTINUOUS FOOTING SCHEDULE

ON S-602 FOR INFORMATION.

CONTRACTION JOINT OR CONSTRUCTION JOINT. SEE E1 & E3/S-501 FOR DETAILS.

COLUMN DESIGNATION. SEE COLUMN SCHEDULE ON S-602 FOR INFORMATION.

8" CONCRETE MASONRY WALL WITH #5 @24" O.C VERTICAL BARS. ALL CELLS WITH

REINFORCING SHALL BE FILLED WITH GROUT. TOP OF WALL ELEVATION = 12'-0" UNO.

8" CONCRETE MASONRY WALL WITH #8 @16" O.C VERTICAL BARS. ALL CELLS WITH

REINFORCING SHALL BE FILLED WITH GROUT. TOP OF WALL ELEVATION = 26'-0" UNO.

LEGEND

FX

CFX

--CJ--

CX

NOT USED

NOT USED

5'-0"x5'-0"x6" CONCRETE STOOP WITH #3 @

18" O.C. PLACE REINFORCING 1.5" FROM TOP

OF CONCRETE. DOWEL REBAR 18" O.C. IN

STOOP INTO HANGAR FOUNDATION. DOWEL

EMBEDMENT DEPTH= 6 INCHES.

(2) HSS12x6x3/8 POSTS FOR JAMB SUPPORT.

TOP OF POSTS AT CATWALK LEVEL.

ADJUSTABLE AT TOP TO ALLOW PLUMBING.

COORDINATE EXACT LOCATIONS WITH DOOR

MANUFACTURER.

SHEET KEYNOTES:

1.

2.

3.

4.

US Army Corps of Engineers ®

SHEET

IDENTIFICATION

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

D . E

LL

ED

G E

S-107

ST

R

U C

TU

R

AL

F

O U

N D

AT

IO

N P

LA

N

-A R

EA

F

JO

IN

T

BA

SE

M

C G

U

IR

E/ D

IX

/L

AK

EH

U R

ST

, N

EW

J

ER

SE

Y

F

ED

ER

AL

P

LA

ZA

N E W

Y O

R K, N Y

C . T

R

AN

C . T

R

AN

A.

M

AG

IN

N

IS

SE

PT

EM

BE

R

RTA SUBMITTAL

KC

-4

6A T

W O

B

AY

G

EN

ER

AL

P U

R P O

SE

M

X H

AN

G

AR

BU

IL

D

IN

G

PR

O

JE

C T

N U

M

BE

R : P

TF

L1

N E W

Y O

R K

D

IS

TR

IC

T

1/8" = 1'-0"A1 STRUCTURAL FOUNDATION PLAN -AREA F

A

KEY PLAN

B

E

G

F

C

D

0' 2' 4' 8' 16'

NORTH

AD

D

ED

U M

IN

R

ES

PO

N

SE

T

O B

ID

D

ER

IN

Q U

IR

IE

S

D

EC

F

G

H

I

J

1 3 4 5 6 7

2'

- 0

22' - 5" 23' - 8" 21' - 2" 22' - 7"

A1 S-201

CF13

T.O.

FTG=-4'-0"

C5

C3

C3

C3

C4

C4

CF3.5

T.O.

FTG=-4'-0"

E7 S-514

2'-0"x2'-0"x2'-0"

SUMP PIT

CF13

T.O.

FTG=-4'-0"

CF10

T.O.

FTG=-4'-0"

EQ.

EQ.

CF3.5

T.O.

FTG=-4'-0"

CF10

T.O.

FTG=-4'-0"

30' - 4"

E1 S-503

E6 S-503

1'

- 2

1' - 5" 1' - 5"

8'

- 1

1' - 5" 1' - 3"

A7 S-505

FOR GENERAL STRUCTURAL NOTES, REFER TO S-001, S-002, AND S-003.

FOR TYPICAL CONCRETE, MASONRY, STEEL DETAILS, REFER TO S-500 SERIES

SHEETS. FOR SCHEDULES, REFER TO S-600 SERIES SHEETS.

ELEVATION 0'-0" = CIVIL ELEVATION 120.85.

SLAB ON GRADE SHALL BE 6" THICK CONCRETE REINFORCED WITH #4@18" O.C.

UNO. REINFORCEMENT SHALL BE PLACED 2" BELOW TOP OF SLAB. TOP OF

SLAB ON GRADE ELEVATION = 0'-0", TYP. WHERE SLAB SLOPES TO DRAIN, THE

HIGH POINTS SHALL BE AT ELEVATION 0'-0".

REFER TO CIVIL DRAWINGS FOR HANGAR PAVEMENT INFORMATION AND

JACKING POINTS AND DESIGN.

SHEET NOTES:

1.

2.

3.

4.

5.

FOOTING DESIGNATION. REFER TO FOOTING SCHEDULE ON S-602 FOR INFORMATION.

CONTINUOUS FOOTING DESIGNATION. REFER TO CONTINUOUS FOOTING SCHEDULE

ON S-602 FOR INFORMATION.

CONTRACTION JOINT OR CONSTRUCTION JOINT. SEE E1 & E3/S-501 FOR DETAILS.

COLUMN DESIGNATION. SEE COLUMN SCHEDULE ON S-602 FOR INFORMATION.

8" CONCRETE MASONRY WALL WITH #5 @24" O.C VERTICAL BARS. ALL CELLS WITH

REINFORCING SHALL BE FILLED WITH GROUT. TOP OF WALL ELEVATION = 12'-0" UNO.

8" CONCRETE MASONRY WALL WITH #8 @16" O.C VERTICAL BARS. ALL CELLS WITH

REINFORCING SHALL BE FILLED WITH GROUT. TOP OF WALL ELEVATION = 26'-0" UNO.

LEGEND

FX

CFX

--CJ--

CX

US Army Corps of Engineers ®

SHEET

IDENTIFICATION

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

D . E

LL

ED

G E

S-108

ST

R

U C

TU

R

A L F

O U

N D

AT

IO

N P

LA

N

-A R

EA

G

J O

IN

T B A

SE

M

C G

U

IR

E/ D

IX

/L

AK

EH

U R

ST

, N

EW

J

ER

SE

Y

F

E D

ER

AL

P

LA

ZA

N

EW

Y O

R K, N Y

C . T

R

AN

C . T

R

AN

A.

M

AG

IN

N

IS

SE

PT

EM

BE

R

RTA SUBMITTAL

KC

-4

6A T

W O

B

AY

G

EN

ER

AL

P U

R

PO

S E M

X H

A N G

AR

BU

I L D

IN

G

PR

O J E

C T

N U

M

BE

R : P

TF

L1

6 3

N

EW

Y O

R K

D

IS

TR

IC

T

1/8" = 1'-0"A1 STRUCTURAL FOUNDATION PLAN -AREA G

A

KEY PLAN

B

E

G

F

C

D

NORTH

0' 2' 4' 8' 16'

AD

D

ED

U M

IN

R

ES

PO

N

SE

T

O B

ID

D

ER

IN

Q U

IR

IE

S

D

EC

1 2 1312

A1 S-201

TRUSS 13. REFER TO S-306 FOR TRUSS INFORMATION.

24' - 0"

40' - 0"

67' - 6"

81' - 0"

W12X40

W12X96

W12X40

W12X40 24' - 0"

40' - 0"

81' - 0"

W12X40

W12X40

W12X40

W12X40

W12X40

HSS7X7X1/4

HS

S7

X7 X1

/4

HSS7X7X1/4

HS

S7

X7 X1

/4

HSS7X7X1/4

HS

S7

X7 X1

/4

HS

S7

X7 X1

/4

HSS7X7X1/4

HS

S7

X7 X1

/4

HSS7X7X1/4

HS

S7

X7 X1

/4

HSS7X7X1/4

4' - 6"195' - 1"4' - 10"

CATWALK

54' - 2"

15' - 5"20' - 6 7/8" 16' - 3 9/16" 20' - 6 7/8"

W12X35 W12X35 W12X35 W12X35

15' - 8 7/8"

W

X7

W

X6

W

X6

W12X35

W12X35 W12X35 W12X35 45' - 4"

W12X35

W12X35 W12X35 W12X35

W

X7

W

X6

W

X6

D1 S-513

14' - 9 7/8"

K)

EXTEND TOP TRUSS CHORD

OVER COLUMN P-2 TO

FRAME INTO COLUMN P-1

EXTEND TOP TRUSS CHORD

OVER COLUMN P-12 TO

FRAME INTO COLUMN P-13

45' - 4"

(+/- 30K)

K)

(+/- 20K)W12X40

K)

(+/- 20K)

K)

(+/- 35K) (+/- 25K)

K)

(+/- 50K)

K)

A1 S-211

A3 S-211

HSS6X

6X

1/4

HSS6X6X1/4

(+/- 80K)

(+/- 30K)

FOR GENERAL STRUCTURAL NOTES, REFER TO S-001, S-002, AND S-003.

THE ELEVATION VIEW IS ONLY SHOWING STEEL IN THE PLANE OF THE COLUMN LINES. WIND GIRTS OUTSIDE THE PLANE OF THE COLUMN LINES ARE NOT SHOWN FOR CLARITY. REFER TO WIND GIRT

ELEVATIONS FOR WIND GIRT INFORMATION.

CONNECTIONS SHALL BE DESIGNED BY STEEL FABRICATOR IN ACCORDANCE WITH AISC STEEL

CONSTRUCTION MANUAL, 14TH EDITION.

PROVIDE 1/2" STIFFENER PLATE (MIN.) EACH SIDE OF BEAM AT BRACE TO BEAM INTERSECTION.

V= MAXIMUM UNFACTORED SHEAR FORCE CARRIED ACROSS CONNECTION (INDICATED SHEAR OCCURS

AT EACH END OF MEMBER, UNO.) "V" INDICATES SHEAR IN VERTICAL DIRECTION, UNO.

P= MAXIMUM UNFACTORED AXIAL LOAD (-FOR TENSION AND + FOR COMPRESSION) IN MEMBER.

FORCES INDICATED ARE UNFACTORED COMBINATIONS OF GRAVITY AND LATERAL LOADS. THESE LOADS

HAVE ALREADY BEEN REDUCED TO ACCOUNT FOR SHORT TERM WIND OR SEISMIC LOADS.

SHEET NOTES:

1.

2.

3.

4.

5.

6.

7.

US Army Corps of Engineers ®

SHEET

IDENTIFICATION

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

D . E

LL

ED

G E

S-207

FR

AM

IN

G

E

LE

VA

TI

O N

A T

G R

ID

L

IN

E

P

BE

T W

EE

N

AN

D

JO

IN

T

BA

SE

M

C G

U

IR

E/ D

IX

/L

AK

EH

U R

ST

, N

EW

J

ER

SE

Y

F

ED

ER

AL

P

LA

ZA

N E W

Y O

R K, N Y

C . T

R

AN

C . T

R

AN

A.

M

AG

IN

N

IS

SE

PT

EM

BE

R

RTA SUBMITTAL

KC

-4

6A T

W O

B

AY

G

EN

ER

AL

P U

R P O

SE

M

X H

AN

G

AR

BU

IL

D

IN

G

PR

O

JE

C T

N U

M

BE

R : P

TF

L1

N E W

Y O

R K

D

IS

TR

IC

T

1/8" = 1'-0"A1 ELEVATION AT GRID LINE P BETWEEN GL 1 AND 13

0' 2' 4' 8' 16'

AD

D

ED

U M

IN

R

ES

PO

N

SE

T

O B

ID

D

ER

IN

Q U

IR

IE

S

D

EC

FIRST FLOOR

0"

13 242314

A1 S-202

A1 S-206

24' - 0"

40' - 0"

67' - 6"

81' - 0"

67' - 6"

40' - 0"

24' - 0"

81' - 0"

W12X40

W12X40

W12X40

W12X40

W12X40

W12X40

W12X40

W12X40

TRUSS 14. REFER TO S-306 FOR TRUSS INFORMATION.

HS

S7

X7 X1

/4

HSS7X7X1/4

HS

S7

X7 X1

/4

HSS7X7X1/4

HSS7X7X1/4

HS

S7

X7 X1

/4

4' - 10"195' - 1"4' - 6"

CATWALK

54' - 2"

W12X35 W12X35 W12X35

W12X35 W12X35 W12X35

W12X35W12X35W12X35

W12X35 W12X35W12X35

EXTEND TOP TRUSS CHORD

OVER COLUMN P-14 TO

FRAME INTO COLUMN P-13.

EXTEND TOP TRUSS CHORD

OVER COLUMN P-23 TO

FRAME INTO COLUMN P-24.

W12X40

45' - 4" 45' - 4"

W

X7

W

X4

W

X4

W

X7

W

X4

W

X4

K)

(+/- 60K) (+/- 30K)

K)

(+/- 25K)

K)

A6 S-211

A8 S-211

UPPER CATWALK

80' - 11"

A1

S-515HSS6X6X1/4

HSS6X6X1/4(+/- 90K) (+/- 30K)

FOR GENERAL STRUCTURAL NOTES, REFER TO S-001, S-002, AND S-003.

THE ELEVATION VIEW IS ONLY SHOWING STEEL IN THE PLANE OF THE COLUMN LINES. WIND GIRTS OUTSIDE THE PLANE OF THE COLUMN LINES ARE NOT SHOWN FOR CLARITY. REFER TO WIND GIRT

ELEVATIONS FOR WIND GIRT INFORMATION.

CONNECTIONS SHALL BE DESIGNED BY STEEL FABRICATOR IN ACCORDANCE WITH AISC STEEL

CONSTRUCTION MANUAL, 14TH EDITION.

PROVIDE 1/2" STIFFENER PLATE (MIN.) EACH SIDE OF BEAM AT BRACE TO BEAM INTERSECTION.

V= MAXIMUM UNFACTORED SHEAR FORCE CARRIED ACROSS CONNECTION (INDICATED SHEAR OCCURS

AT EACH END OF MEMBER, UNO.) "V" INDICATES SHEAR IN VERTICAL DIRECTION, UNO.

P= MAXIMUM UNFACTORED AXIAL LOAD (-FOR TENSION AND + FOR COMPRESSION) IN MEMBER.

FORCES INDICATED ARE UNFACTORED COMBINATIONS OF GRAVITY AND LATERAL LOADS. THESE LOADS

HAVE ALREADY BEEN REDUCED TO ACCOUNT FOR SHORT TERM WIND OR SEISMIC LOADS.

SHEET NOTES:

1.

2.

3.

4.

5.

6.

7.

US Army Corps of Engineers ®

SHEET

IDENTIFICATION

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

D . E

LL

ED

G E

S-208

FR

AM

IN

G

E

LE

VA

TI

O N

A T

G R

ID

L

IN

E

P

BE

TW

EE

N

A N

D

JO

IN

T

BA

SE

M

C G

U

IR

E/ D

IX

/L

AK

EH

U R

ST

, N

EW

J

ER

SE

Y

F

ED

ER

AL

P

LA

ZA

N E W

Y O

R K, N Y

C . T

R

AN

C . T

R

AN

A.

M

AG

IN

N

IS

SE

PT

EM

BE

R

RTA SUBMITTAL

KC

-4

6A T

W O

B

AY

G

EN

ER

AL

P U

R P O

SE

M

X H

AN

G

AR

BU

IL

D

IN

G

PR

O

JE

C T

N U

M

BE

R : P

TF

L1

N E W

Y O

R K

D

IS

TR

IC

T

1/8" = 1'-0"A1 FRAMING ELEVATION ALONG GRID LINE P BETWEEN 13 AND 24

0' 2' 4' 8' 16'

AD

D

ED

U M

IN

R

ES

PO

N

SE

T

O B

ID

D

ER

IN

Q U

IR

IE

S

D

EC

1 1

SEE FDN. PLAN

CMU WALL

DOWEL TO MATCH

VERTICAL WALL REINF.

FOOTING

REINFORCING,

SEE SCHEDULE

ON S-602

#30 FELT

GRID

CONCRETE SLAB

OR HANGAR

PAVEMENT

SE

E

SC

HE

DU

LE

COLUMN, SEE SCHEDULE

HANGAR PAVEMENT,

SEE CIVIL

#30 FELT

CONTINUE STEMWALL

REINF. THROUGH

PEDESTAL - TYPICAL

1'

- 6

CONCRETE INFILL

#3 TIES AT 10" O.C. (3

AT 2" O.C. TOP)

(18) #7 HOOKED DOWELS

1' - 8"

3" CLR. TYP

3" C

LR

. T

YP EQUAL EQUAL

SEE SCHEDULE

1' - 8"

SEE FDN.

PLAN

CMU WALL

DOWEL TO MATCH

VERTICAL WALL REINF.

HANGAR PAVEMENT,

SEE CIVILFINISHED GRADE,

SEE CIVIL

FOOTING

REINFORCING,

SEE SCHEDULE

ON S-602

PREFORMED JOINT FILLER

SE

E

SC

HE

DU

LE

SEE SCHEDULE

1' - 4"

VENEER, SEE ARCH.

INSULATION / THERMAL

BARRIER, SEE ARCH.

PERIMETER RIGID

INSULATION, SEE ARCH.

GRID

EQUAL EQUAL

TYP.

3" CLR.

TY

P.

3" C

LR

#5 AT 16" O.C.

(4) #5

CONTINUOUS

EACH FACE

11"

#5 DOWELS AT 16" O.C.

CL

R.2"

8"

(2) #5 CONT. BARS

4"

2" CLR. TYP.

SEE FDN.

PLAN

COLUMN, SEE SCHEDULE

DOWEL TO MATCH

VERTICAL WALL REINF.

HANGAR PAVEMENT OR

SLAB-ON-GRADEFINISHED GRADE,

SEE CIVIL

FOOTING

REINFORCING, SEE

SCHEDULE ON S-602

#30 FELT FOR SLAB ON GRADE;

PREFORMED JOINT FILLER FOR

HANGAR PAVEMENT

SE

E

SC

HE

DU

LE

SEE SCHEDULE

VENEER, SEE ARCH.

INSULATION / THERMAL

BARRIER, SEE ARCH.

PERIMETER RIGID

INSULATION, SEE ARCH.

GRID

EQUAL EQUAL

TYP.

3" CLR.

TY

P.

3" C

LR

CONTINUE STEMWALL

REINF. THROUGH

PEDESTAL - TYPICAL

1'

- 6

CONCRETE INFILL

CMU WALL

#3 TIES AT 10" O.C. (3

AT 2" O.C. TOP) (10) #5 HOOKED DOWELS

2' - 3" 1' - 2"

CL

R.2"

8"

4"

E9 S-503

EXTERIOR

CONCRETE,

SEE CIVIL

WALL BEYOND

SEE FDN.

PLAN

FOOTING

REINFORCING,

SEE SCHEDULE

ON S-602

#30 FELT

SE

E

SC

HE

DU

LE

SEE SCHEDULE

PERIMETER RIGID

INSULATION, SEE ARCH.

GRID

EQUAL EQUAL

TYP.

3" CLR.

TY

P.

3" C

LR

(4) #5

CONTINUOUS

EACH FACE

#5 DOWELS AT 16" O.C.

CL

R.2"

HANGAR PAVEMENT,

SEE CIVIL

SEE FDN.

PLAN

CMU WALL

DOWEL TO MATCH

VERTICAL WALL REINF.

FINISHED GRADE,

SEE CIVIL

FOOTING

REINFORCING,

SEE SCHEDULE

ON S-602

SE

E

SC

HE

DU

LE

SEE SCHEDULE

1' - 4"

VENEER, SEE ARCH.

INSULATION / THERMAL

BARRIER, SEE ARCH.

PERIMETER RIGID

INSULATION, SEE ARCH.

GRID

EQUAL EQUAL

TYP.

3" CLR.

TY

P.

3" C

LR

#5 AT 16" O.C.

(4) #5

CONTINUOUS

EACH FACE

11"

#5 DOWELS AT 16" O.C.

CL

R.2"

8"

(2) #5 CONT. BARS

4"

2" CLR. TYP.

CONCRETE SLAB

#30 FELT

EXTERIOR

CONCRETE,

SEE CIVIL

WALL BEYOND

SEE FDN.

PLAN

CONCRETE SLAB

FOOTING

REINFORCING,

SEE SCHEDULE

ON S-602

#30 FELT

SE

E

SC

HE

DU

LE

SEE SCHEDULE

PERIMETER RIGID

INSULATION, SEE ARCH.

GRID

EQUAL EQUAL

TYP.

3" CLR.

TY

P.

3" C

LR

(4) #5

CONTINUOUS

EACH FACE

#5 DOWELS AT 16" O.C.

CL

R.2"

GRID

GRID

(10) #5 HOOKED

DOWELS

#3 TIE SETS AT 10" O.C.

(3 AT 2" O.C. TOP)

CONCRETE

PEDESTAL

2'

- 4

EQ

EQ

1' - 4" 11" 1' - 2"

CONTINUE STEM

WALL REINFORCING

THROUGH PEDESTAL

2" C

LR

. T

YP

US Army Corps of Engineers ®

SHEET

IDENTIFICATION

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

D . E

LL

ED

G E

S-503

FO

U

N D

AT

IO

N D

E T

AI

LS

JO

IN

T

BA

SE

M

C G

U

IR

E/ D

IX

/L

AK

EH

U R

ST

, N

EW

J

ER

SE

Y

F

ED

ER

AL

P

LA

ZA

N E W

Y O

R K, N Y

C . T

R

AN

C . T

R

AN

A.

M

AG

IN

N

IS

SE

PT

EM

BE

R

RTA SUBMITTAL

KC

-4

6A T

W O

B

AY

G

EN

ER

AL

P U

R P O

SE

M

X H

AN

G

AR

BU

IL

D

IN

G

PR

O

JE

C T

N U

M

BE

R : P

TF

L1

N E W

Y O

R K

D

IS

TR

IC

T

3/4" = 1'-0"A6 TYPICAL INTERIOR HANGAR COLUMN FOUNDATION

3/4" = 1'-0"E1

TYPICAL EXTERIOR WALL FOUNDATION

SECTION AT HANGAR

3/4" = 1'-0"E6

TYPICAL FOUNDATION SECTION AT

EXTERIOR COLUMN AT HANGAR

3/4" = 1'-0"E3

FOUNDATION SECTION AT DOOR

AT HANGAR

3/4" = 1'-0"A1 EXTERIOR WALL FOUNDATION SECTION

3/4" = 1'-0"A3 TYPICAL FOUNDATION SECTION AT DOOR

3/4" = 1'-0"E9 TYPICAL CONCRETE PEDESTAL DETAIL

0' 1' 2' 3'3" 6" 0' 1' 2' 3'3" 6" 0' 1' 2' 3'3" 6" 0' 1' 2' 3'3" 6"

0' 1' 2' 3'3" 6"0' 1' 2' 3'3" 6"0' 1' 2' 3'3" 6"

AD

D

ED

U M

IN

R

ES

PO

N

SE

T

O B

ID

D

ER

IN

Q U

IR

IE

S

D

EC

SEE FDN.

PLAN

HSS COLUMN,

SEE SCHEDULE

DOWEL TO MATCH

VERTICAL WALL REINF. CONCRETE SLAB

FINISHED GRADE,

SEE CIVIL

FOOTING

REINFORCING, SEE

SCHEDULE ON S-602

#30 FELT

SE

E

SC

HE

DU

LE

SEE SCHEDULE

VENEER, SEE ARCH.

INSULATION / THERMAL

BARRIER, SEE ARCH.

PERIMETER RIGID

INSULATION, SEE ARCH.

GRID

EQUAL EQUAL

TYP.

3" CLR.

TY

P.

3" C

LR

CONTINUE STEMWALL

REINF. THROUGH

PEDESTAL - TYPICAL

1'

- 6

CONCRETE INFILL

CMU WALL

#3 TIES AT 10" O.C. (3

AT 2" O.C. TOP)

(8) #5 HOOKED DOWELS

1' - 9"1' - 4" @ 8" CMU 5"

5/8" GUSSET

PLATE

7/16

TYP.

HSS BRACE

NOTCH AT

GUSSET PLATE

TYP.

1"CLR.

1"

1/4 8

1/4 8

8"

4"

SEE FDN.

PLAN

HSS COLUMN,

SEE SCHEDULE

DOWEL TO MATCH

VERTICAL WALL REINF.

CONCRETE SLAB

FOOTING

REINFORCING, SEE

SCHEDULE ON S-602

#30 FELT

SE

E

SC

HE

DU

LE

SEE SCHEDULE

GRID

EQUAL EQUAL

TYP.

3" CLR.

TY

P.

3" C

LR

CONTINUE STEMWALL

REINF. THROUGH

PEDESTAL - TYPICAL

1'

- 6

CONCRETE INFILL

CMU WALL

(8) #5 HOOKED DOWELS

11"8"

CL

R.2"

2" CLR. TYP.

CONCRETE SLAB

#30 FELT

#3 TIES AT 10" O.C. (3

AT 2" O.C. TOP)

1' - 4"

E4 S-505

SEE FDN.

PLAN

CONCRETE SLAB

FOOTING

REINFORCING, SEE

SCHEDULE ON S-602

#30 FELT

SE

E

SC

HE

DU

LE

SEE SCHEDULE

GRID

EQUAL EQUAL

TYP.

3" CLR.

TY

P.

3" C

LR

WALL BEYOND

CL

R.2"

CONCRETE SLAB

(3) #4 CONTINUOUS

#4 VERTICALS AT

12" O.C.

(2) #5 CONTINUOUS

BOTTOM

8"8"

SEE FDN.

PLAN

DOWEL TO MATCH

MASONRY REINF.

CONCRETE SLAB

FOOTING

REINFORCING, SEE

SCHEDULE ON S-602

#30 FELT

SE

E

SC

HE

DU

LE

SEE SCHEDULE

GRID

EQUAL EQUAL

TYP.

3" CLR.

TY

P.

3" C

LR

CMU WALL

CL

R.2"

CONCRETE SLAB

#30 FELT

(3) #4 CONTINUOUS

(2) #5 CONTINUOUS

TOP

#4 VERTICALS AT

12" O.C.

(2) #5 CONTINUOUS

BOTTOM

8"8"

GRID

GRID

(8) #5 HOOKED

DOWELS

#3 TIE SETS AT 10" O.C.

(3 AT 2" O.C. TOP)

CONCRETE

PEDESTAL

11"8"8"

CONTINUE STEM

WALL REINFORCING

THROUGH PEDESTAL

CONCRETE SLAB

#30 FELT

HSS COLUMN,

SEE SCHEDULEGRID

CONCRETE INFILL

SEE FDN.

PLAN

FOOTING

REINFORCING, SEE

SCHEDULE ON S-602

SE

E

SC

HE

DU

LE

SEE SCHEDULE

EQUAL EQUAL

8"

8"

1' - 0" 2' - 0"

8"

EDGE OF STEM WALL

BEYOND #4@12" O.C.

REFER TO FOOTING

SCHEDULE FOR

REINFORCING INFO

WALL REINF.

#4 @ 12"O.C.

#4 @ 12"O.C. MAX. (4) #3 HORIZ. BARS

1/

2"

#4 HORIZ. @12" O.C.

#4 HORIZ. @9" O.C.

COMPACTED FILL

BETWEEN SUMP PIT AND

TOP OF FOOTING

US Army Corps of Engineers ®

SHEET

IDENTIFICATION

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

D . E

LL

ED

G E

S-505

FO

U

N D

A T

IO

N D

ET

A I

LS

J O

IN

T B A

SE

M

C G

U

IR

E/ D

IX

/L

AK

EH

U R

ST

, N

EW

J

ER

SE

Y

F

E D

ER

AL

P

LA

ZA

N

EW

Y O

R K, N Y

C . T

R

AN

C . T

R

AN

A.

M

AG

IN

N

IS

SE

PT

EM

BE

R

RTA SUBMITTAL

KC

-4

6A T

W O

B

AY

G

EN

ER

AL

P U

R

PO

S E M

X H

A N G

AR

BU

I L D

IN

G

PR

O J E

C T

N U

M

BE

R : P

TF

L1

6 3

N

EW

Y O

R K

D

IS

TR

IC

T

3/4" = 1'-0"A4 TYPICAL ADMIN COLUMN @ BRACE LOCATIONS

3/4" = 1'-0"E1

FOUNDATION SECTION AT INTERIOR COLUMN

AND MASONRY WALL AT ADMIN AREA

3/4" = 1'-0"E9

FOUNDATION SECTION AT INTERIOR

DOOR AT ADMIN AREA

3/4" = 1'-0"E6

FOUNDATION SECTION AT INTERIOR

MASONRY WALL AT ADMIN AREA

3/4" = 1'-0"E4 DETAIL

3/4" = 1'-0"C1 TYPICAL INTERIOR COLUMN FOUNDATION

0' 1' 2' 3'3" 6" 0' 1' 2' 3'3" 6" 0' 1' 2' 3'3" 6" 0' 1' 2' 3'3" 6"

0' 1' 2' 3'3" 6"

0' 1' 2' 3'3" 6"

AD

D

ED

U M

IN

R

ES

PO

N

SE

T

O B

ID

D

ER

IN

Q U

IR

IE

S

D

EC

A7 SUMP PIT SECTION

0' 1' 2' 3'3" 6"

1'

- 8

PE

R

SC

HE

DU

LE

PER SCHEDULE

TYP.

3"

1' - 8"

5/16

THICKNESS

PER SCHEDULE

PEDESTAL PER

FOUNDATION

DRAWINGS

ANCHOR BOLTS

PER SCHEDULE

TY

P.3"

3/8

2"

1' - 0"

7"

SHEAR KEY,

HSS8X8X3/8"

NON-SHRINK

GROUT

HOLE DIA. PER

SCHEDULE10" 10"

GUSSET PLATE

BY OTHERS

1' - 8"

5/16

HOLE DIA. PER

SCHEDULE

1' - 8"1' - 8" 10" 10"

TYP.

5" 1' - 8"

TY

P.5"

1'

- 8

PE

R

SC

HE

DU

LE

THICKNESS

PER SCHEDULE

PEDESTAL PER

FOUNDATION

DRAWINGS

ANCHOR BOLTS

PER SCHEDULE

3/8

2"

1' - 0"

7"

SHEAR KEY,

HSS8X8X3/8"

NON-SHRINK

GROUT

GUSSET PLATE

BY OTHERS

5/16

HOLE SIZE PER

SCHEDULE

7"

PE

R

SC

HE

DU

LE

THICKNESS

PER SCHEDULE

PEDESTAL PER

FOUNDATION

DRAWINGS

ANCHOR BOLTS

1/

4"

NON-SHRINK

GROUT

TYP.

4"

TY

P.4"

PER SCHEDULE

7"

7" 8"

8" 7"

US Army Corps of Engineers ®

SHEET

IDENTIFICATION

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

D . E

LL

ED

G E

S-506

TY

PI

C

AL

B

AS

E

PL

AT

E

D

ET

AI

LS

JO

IN

T

BA

SE

M

C G

U

IR

E/ D

IX

/L

AK

EH

U R

ST

, N

EW

J

ER

SE

Y

F

ED

ER

AL

P

LA

ZA

N E W

Y O

R K, N Y

C . T

R

AN

C . T

R

AN

A.

M

AG

IN

N

IS

SE

PT

EM

BE

R

RTA SUBMITTAL

KC

-4

6A T

W O

B

AY

G

EN

ER

AL

P U

R P O

SE

M

X H

AN

G

AR

BU

IL

D

IN

G

PR

O

JE

C T

N U

M

BE

R : P

TF

L1

N E W

Y O

R K

D

IS

TR

IC

T

3/4" = 1'-0"E1 TYPICAL SHEAR KEY BASEPLATE AT HANGAR

0' 1' 2' 3'3" 6" 3/4" = 1'-0"E7 BASE PLATE AT COLUMN I/13

0' 1' 2' 3'3" 6"

AD

D

ED

U M

IN

R

ES

PO

N

SE

T

O B

ID

D

ER

IN

Q U

IR

IE

S

D

EC

ROOF DECK FASTENER PATTERN

STEEL DECK SCHEDULE

LOW

ROOF 1.5B20

MARK

1.5"

DEPTH

B

TYPE

GAGE I

in4/ft

0.201

Sp in3/ft

0.234

Sn in3/ft

0.247 fy ksi

SUPPORTS

PATTERN TYPE

36/4 5/8" PUDDLE WELDS

DECK TYPE SECTION PROPERTIES FASTENERS

SPACING

12" O.C.

TYPE

#10 SCREWS

DESIGN

DIAPHRAGM

SHEAR

(plf)

36/4 PATTERN

DECK CONNECTIONS:

USE (4) #10 TEK SCREWS PER SPAN AT SIDELAP.

PINS SHALL BE HILTI ENP2 SERIES OR EQUAL, POWER DRIVEN FASTENERS.

WELDS MAY BE SUBSTITUTED FOR PINS WHEN ATTACHING TO STRUCTURAL STEEL SHAPES GREATER THAN 1/4" THICKNESS.

DECK MANUFACTURER SHALL SUBMIT AN ICBO NUMBER AND/OR CALCULATIONS, PREPARED IN ACCORDANCE WITH THE SDI DIAPHRAGM DESIGN MANUAL, SECOND EDITION, TO SHOW THE STEEL DECK AND THE CONCRETE FLOOR SYSTEM HAS AN EFFECTIVE DIAPHRAGM SHEAR CAPACITY EQUAL

OR GREATER THAN THE VALUE SHOWN IN THE SCHEDULE.

SIDE LAPS

SCREWS SHALL BE SELF-DRILLING TEKS SCREWS.

HANGAR

ROOF 1.5B20 1.5" B 20 0.201 0.234 0.247 33 36/4 5/8" PUDDLE WELDS 12" O.C. #10 SCREWS

ANCHOR BOLT SCHEDULE

HEAVY HEX NUT AND

WASHER

CONNECTED PLATE

1" GROUT BED

LEVELING NUT

AND WASHER

ANCHOR RODS SHALL BE

ASTM F1554 GR. 36 UNO

TACK WELD NUT TO

THREADED ROD

TOP OF

CONCR.

EM

BE

DM

EN

T

ANCHOR BOLT DIAMETER

(IN.)

EMBEDMENT

(IN.) (U.N.O.)

1/2 8 5/8 9 3/4 12 7/8 17 1 20

1 1/4 24 1 1/2 30

NOTE: IF EMBEDMENTS INDICATED EXTEND BEYOND BOTTOM

OF REINFORCING IN FOOTING, SHORTEN ANCHOR BOLT SUCH

THAT NUT IS AT SAME ELEVATION AS BOTTOM FOOTING

REINFORCING. ALL INFORMATION IN THIS TABLE IS

SUPERSEDED BY ANY CONTRADICTORY INFORMATION LISTED

ON SPECIFIC DETAILS.

MINIMUM REINFORCING

DEVELOPMENT AND SPLICE LENGTH

SCHEDULE PER ACI 318

NOTES:

1. TABULATED DATA IN THIS SCHEDULE IS APPLICABLE TO MOST BAR

CONDITIONS BUT MAY NOT APPLY TO ALL CASES. PLEASE REFER TO

CODE REQUIREMENTS FOUND IN ACI 318 AND/OR CRSI DESIGN

HANDBOOK (LATEST EDITIONS) FOR MORE STRINGENT REQUIRED

MINIMUM DEVELOPMENT AND SPLICE LENGTHS.

2. THIS TABLE ASSUMES THAT NON-EPOXY-COATED STRAIGHT BARS

HAVE CONCRETE COVER > Edb.

3. THIS TABLE ASSUMES NON-EPOXY-COATED HOOKED BARS.

4. VALUES FOR MINIMUM SPLICE LENGTH ARE BASED ON CLASS B

SPLICE VALUES.

#3

REINFORCING YIELD STRENGTH, Fy = 60 KSI f'c = 4,000 PSI

BAR

SIZE

REQUIRED DEVELOPMENT

LENGTH

STRAIGHT

BARS (IN.)

HOOKED

BARS (IN.)

#4

#5

#6

#7

#8

#9

#10

#11

REQUIRED

SPLICE

LENGTH (IN.)

FOOTING SCHEDULE

MARK REINF. TYP. U.N.O.

(EA. WAY U.N.O.)

FOOTING SIZE

F3

F6

3'-0"x3'-0"x1'-0"

6'-0"x6'-0"x1'-2"

(3) #5 E.W, BOTTOM

(6) #5 E.W, BOTTOM

F5 5'-0"x5'-0"x1'-0" (5) #5 E.W, BOTTOM

F4 4'-0"x4'-0"x1'-0" (4) #5 E.W, BOTTOM

F18 18'-0"x18'-0"x2'-6"

F25

#7@10" O.C., E.W., TOP & BOTTOM

25'-0"x25'-0"x3'-6" #8@8" O.C., E.W., TOP & BOTTOM

CONTINUOUS FOOTING SCHEDULE

MARK REINF. TYP. U.N.O.

(EA. WAY U.N.O.)

FOOTING SIZE

CF5 5'-0" W x 1'-6" (THICK) #5 @12" O.C., E.W., TOP & BOTTOM

CF10 10'-0" W x 2'-0" (THICK) #6@10" O.C., E.W., TOP & BOTTOM

CF13 13'-0" W x 2'-6" (THICK) #7@10" O.C., E.W., TOP & BOTTOM

CF3.5 3'-6" W x 1'-6" (THICK) #5 @12" O.C., E.W., TOP & BOTTOM

CF5.5 5'-6" W x 1'-6" (THICK) #5 @12" O.C., E.W., TOP & BOTTOM

CF24 24'-0" W x 3'-6" (THICK) #8@8" O.C., E.W., TOP & BOTTOM

STEEL COLUMN SCHEDULE

COLUMN

MARK

C1

ADMIN/ LOW ROOF

FIRST FLOOR

BASE PLATE

ANCHOR BOLTS

* BASE AND CAP PLATES MAY BE A36 OR A592. CAP PLATES ARE 1/4" THICKNESS AT

NON-BEARING CONDITIONS. 3/4" THICKNESS @ BEARING CONDITIONS.

* ANCHOR BOLTS F1554, GR. 36 U.N.O.

C2

HS

S 8x

8x 3/

C3

W x2

C4

W x1

C5

HANGAR ROOF

HS

S x1

0x 3/

C6

NON-BRACED

LOCATIONS

TYPE "3"

3/4"x1'-4"x1'-4"

BRACED

LOCATIONS

SEE A7& A9/S-504

NON-BRACED

LOCATIONS

BRACED

LOCATIONS

SEE A7 & A9/S-504

(4) - 3/4" DIA.

NON-BRACED

LOCATIONS

TYPE "3"

3/4"x1'-2"x1'-2"

BRACED

LOCATIONS

NON-BRACED

LOCATIONS

BRACED

LOCATIONS

(4) - 3/4" DIA.

W x1

W x7

SEE A7& A9/S-504

SEE A7 & A9/S-504

SEE E7/S-506

3"x2'-6"x2'-6"

(12) 1 1/2" DIA. ASTM

F1554 GR. 105 x

24" EMBED.

NON-BRACED

LOCATIONS

TYPE "1"

1 1/4"x1'-6"x1'-6"

BRACED

LOCATIONS

EXCEPT I/1 & I/24

SEE E1/S-506

2"x2'-2"x2'-2"

NON-BRACED

LOCATIONS

(4) - 1 1/2" DIA.

x24" EMBED.

BRACED LOCATIONS

SEE E1/S-506

(6) 1 3/4" DIA. x

24" EMBED

NON-BRACED

LOCATIONS

TYPE "1"

1 1/4"x1'-6"x1'-6"

BRACED

LOCATIONS

EXCEPT E/6 & E/19

SEE E1/S-506

2"x2'-2"x2'-2"

NON-BRACED

LOCATIONS

TYPE "1"

1 1/4"x1'-6"x1'-6"

BRACED

LOCATIONS

SEE E1/S-506

1.5"x2'-2"x2'-2"

NON-BRACED

LOCATIONS

NON-BRACED

LOCATIONS

ANGLED BRACED

LOCATIONS: I/1 &

I/24

SEE E1/S-506

2"x2'-6"x2'-6"

ANGLED BRACED

LOCATIONS:E/6 &

E/19

SEE E1/S-506

2"x2'-6"x2'-6"

(4) - 1 1/2" DIA.

x24" EMBED.

(4) - 1 1/2" DIA.

x24" EMBED.

BRACED LOCATIONS

SEE E1/S-506

(6) 1 3/4" DIA. x

24" EMBED

BRACED LOCATIONS

SEE E1/S-506

(6) 1 3/4" DIA. x

24" EMBED

US Army Corps of Engineers ®

SHEET

IDENTIFICATION

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

D . E

LL

ED

G E

S-602

S T R

U C

TU

R

A L S

C H

ED

U

L E S, S H

EE

T

JO

IN

T

BA

SE

M

C G

U

IR

E/ D

IX

/L

AK

EH

U R

ST

, N

EW

J

ER

SE

Y

F

ED

ER

AL

P

LA

ZA

N E W

Y O

R K, N Y

C . T

R

AN

C . T

R

AN

A.

M

AG

IN

N

IS

SE

PT

EM

BE

R

RTA SUBMITTAL

KC

-4

6A T

W O

B

AY

G

EN

ER

AL

P U

R P O

SE

M

X H

AN

G

AR

BU

IL

D

IN

G

PR

O

JE

C T

N U

M

BE

R : P

TF

L1

N E W

Y O

R K

D

IS

TR

IC

T

AD

D

ED

U M

IN

R

ES

PO

N

SE

T

O B

ID

D

ER

IN

Q U

IR

IE

S

D

EC

FD

FDFD

FD

FD FD

A1

AE201

ELECTRICAL

COMM

GO-81

BREAK

CTK

TIRE SHOP

CORRIDOR

WOMEN

MEN

JANITOR

MECHANICAL

VESTIBULE

VESTIBULE

122J 117H

1A

5A

109A

5A 10

1A

6A

7A

7A

117C122E

122F 117D

122B 117B

122D

110A 110B

113A

4A 10

2A

108A

AE401

D5

AE401

A2

AE401

A5

C5

AE302

A3

AE303

A6

AE305

A3

AE304

A1

AE310

A1

AE305

A

B

C

D

E 7 8 9 10 11 13 15 16 17 18

LOCKER

112A

LOCKER

116C

CORRIDOR

CORRIDOR

CORRIDOR

112A 116A

8" 1'-1" 16'-5" 18'-7" 15'-11" 1'-4" 8" 5'-8" 8" 9'-8" 15'-4" 24'-0" 15'-0" 8" 5'-8" 8"1'-4" 28'-4 1/2" 8'-6 1/2" 1'-1" 8"

170'-8"

'-8

1'- 1"

'-6

'-2

'-3

6'-

8"

1'- 1"

4'- 3"

'-5

2'-

6"

'-8

1'- 9"

3'- 4"

7"

'-8

1'- 1"

4'- 3"

'-5

2'-

7'- 2"

'-0

1'-

0"

1'- 9"

3'- 4"

7"

'-8

7"

7'-5" 9'-11" 15'-4" 12'-1" 11'-11" 9" 14'-0" 7'-3"

'-8

AE501

D7

AE501

A4

AE501

D7

OPP

AE501

A4

OPP

AE501

A7

B1

B1

B1

A2

B1

B1

A1 B1

B1

A2

B1

A2

A2

A1

B1

A2

B1

B1 A1

C1

E1

E1

1'-2" 16'-0" 1'-5" 1'-7" 8'-4" 6'-0"

8"

3'-4"

1'-8"

8" 6'-4" 8'-4" 2'-0" 4'-4" 1'-0" 6'-4" 2'-8" 16'-0" 2'-4 1/2"

1'-8"

3'-4"

8"

8"

'-7

'-2

'-3

8" 5'-

4"

1"

7" 1'-

5"

4"3'- 4"

1'- 8"2'-

4"

'-0

1'-

1'-

1" 1'-

1" 6'-

4"

'-1

AR

EA

B

AR

EA

G

AR

EA

C

AR

EA

B

AR

EA

A

AR

EA

A

4" 3'- 4"

1'- 8" 8"

C1

ALCOVE

ALCOVE

SHOWER

116B

SHOWER

112B

AI205

A1

AI205

D1

17.1 18.1

A3

AE402

AE402

E4

D6

AE203

AE102

F1 AE102

F3

A4

AE305

A2

7'-6 1/2"

'-0

65'-4"

122A

2C

B1

1'-0" 5'-0"

1'-0"

7'- 4"

NOTE: REFER TO PLANS FOR BOLLARD LOCATIONS

AND STOOP LOCATIONS

3" AS SCHEDULED 3"

2'- 0"

2'- 0"

3" 3"

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

DR

AW

N

BY

DE

SI

GN

ED

B Y:

SU

BM

IT

TE

D

BY

SI

ZE

CH

EC

KE

D

BY

AN

SI

D

IS

SU

E

DA

TE

CO

NT

RA

CT

N O.

SO

LIC

IT

AT

IO

N

NO

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

DA

TE

MA

RK

DE

SC

RI

PT

IO

N

AE102

FL

O

O R

P

LA

N

AR

EA

A

J O

IN

T B A

SE

M

C G

U

IR

E/ D

IX

/L

AK

EH

U R

ST

, N

EW

J

ER

SE

Y

F

E D

ER

AL

P

LA

ZA

N

EW

Y O

R K , N Y

J

LA

R

SS

O N

G U

EC

KE

R

Q R

EM

Y

R W

EN

TE

SE

PT

EM

BE

R

RTA SUBMITTAL

KC

-4

6A T

W O

B

AY

G

EN

ER

AL

P U

R

PO

S E M

X H

A N G

AR

BU

I L D

IN

G

PR

O J E

C T

N U

M

BE

R : P

TF

L1

6 3

N

EW

Y O

R K

D

IS

TR

IC

T

1/8" = 1'-0"A1 FLOOR PLAN - AREA A

A

KEY PLAN

B

E

G

F

C

D 0' 2' 4' 8' 16'

SHEET KEYNOTES

1 BRICK EXPANSION JOINT

2 BOLLARDS RE: STRUCT FOR DETAILS

3 WATER BOTTLE FILLER RE: PLUMBING

4 STAINLESS STEEL CTK SERVICE COUNTER

5 EMERGENCY EYEWASH/SHOWER RE:

PLUMBING

6 DOWNSPOUT TO STORM SYSTEM, MATCH

ADJACENT SURFACES

7 CONCRETE STOOP, RE: STRUCT

8 GYP BOARD EXPANSION JOINT COVER

9 CMU EXPANSION JOINT COVER

10 NOT USED

11 FLOOR DRAIN, RE: PLUMBING

SLOPE FLOOR TO DRAIN

NORTH

GENERAL SHEET NOTES

1 INSTALL CORNER GUARDS AT ALL

OUTSIDE CORNERS OF GYPSUM BOARD

WALLS.

2 FINISH FLOORELEVATION OF 0'-0" IS

EQUIVALENT TO 120.85' CIVIL ELEVATION.

1/4" = 1'-0"F1

TYPICAL BOLLARDS AND STOOP AT

DOUBLE DOORS

1/4" = 1'-0"F3

TYPICAL BOLLARDS AT OVERHEAD

DOOR

0' 1' 2' 4' 8' 0' 1' 2' 4' 8'

NORTH NORTH

AD

DE

ND

UM

IN

R

ES

PO

NS

E T O

B

ID

DE

R

IN

QU

IR

IE

S 0 3

D

EC

1 8

S-103
Sheets
S-103 - STRUCTURAL FOUNDATION PLAN -AREA B
S-104 - STRUCTURAL FOUNDATION PLAN -AREA C
S-105 - STRUCTURAL FOUNDATION PLAN -AREA D
S-106 - STRUCTURAL FOUNDATION PLAN -AREA E
S-107 - STRUCTURAL FOUNDATION PLAN -AREA F
S-108 - STRUCTURAL FOUNDATION PLAN -AREA G
S-207 - FRAMING ELEVATION AT GRID LINE P BETWEEN 1 AND 13
S-208 - FRAMING ELEVATION AT GRID LINE P BETWEEN 13 AND 24
S-503 - FOUNDATION DETAILS
S-506 - TYPICAL BASE PLATE DETAILS
S-602 - STRUCTURAL SCHEDULES, SHEET 1
S-104
Sheets

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.