The first document is a set of architectural plans for an Army Reserve Training Center located in Horsham, Pennsylvania. It provides details for the first floor plan of the East Training Center building, including room layouts, dimensions, notes and specifications. Key elements include concrete and metal construction, fire-rated wall assemblies, storage rooms, offices, mechanical and electrical spaces, a staging area and armory. The project involves repair and renovation work for HVAC systems at the specified facility.

The second document is a solicitation notice from the Department of the Army Corps of Engineers Engineering District Philadelphia for HVAC systems repairs at the PA 206 Horsham Army Reserve Training Center in Horsham, Pennsylvania. The opportunity is designated as a Special Notice. No further information is provided regarding response dates, award dates, pricing or other contractual terms.

View the file

Other files

File Type Posted
W912BU24R0001 Amendment 0009_Cancellation.pdf PDF
W912BU24R0001 Amendment 0005.pdf PDF
10-M-800.pdf PDF
AF85D7-1.PDF PDF
AFA040-1.PDF PDF
00-M-806.pdf PDF
AF0F76-1.PDF PDF
00-MP-4.PDF PDF
AF6B67-1.PDF PDF
10-M-803.pdf PDF
AFDA0C-1.PDF PDF
00-M-201.pdf PDF
AF7DA6-1.PDF PDF
AF5B0D-1.PDF PDF
AF4200-1.PDF PDF
10-MH-1.PDF PDF
AF2EB8-1.PDF PDF
AF7BD0-1.PDF PDF
AF4273-1.PDF PDF
00-M-803.pdf PDF
10-M-801.pdf PDF
00-MP-2.PDF PDF
AF1533-1.PDF PDF
AF9D68-1.PDF PDF
AFC2EA-1.PDF PDF
AF2AEE-1.PDF PDF
AFD99B-1.PDF PDF
AF26AC-1.PDF PDF
W912BU24R0001 Amendment 0004.pdf PDF
AFFB36-1.PDF PDF
00-M-807.pdf PDF
00-M-808.pdf PDF
AF9FDC-1.PDF PDF
AF47CB-1.PDF PDF
AFRC55-2.PDF PDF
00-M-802.pdf PDF
AFFC3F-1.PDF PDF
AFC8A7-1.PDF PDF
AF8E75-1.PDF PDF
AFD903-1.PDF PDF
AF54B2-1.PDF PDF
AFD078-1.PDF PDF
00-MH-1.PDF PDF
AF0EF7-1.PDF PDF
00-MP-1.PDF PDF
00-M-805.pdf PDF
00-MH-4.PDF PDF
AF377B-1.PDF PDF
AF9D55-1.PDF PDF
AFE9FE-1.PDF PDF
Show 40 more

Latest 50 of 102 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

00-A-1041/8" = 1’ 0" A4

FIRST FLOOR PLAN - EAST

T R

A

IN

IN

G C

E N

T E

R F

IR

S T F

L O

O R P

L A

N E

A S

T

REVISED AS-BUILT

F

IE

L D C

O N

D

IT

IO

N

S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5500-A-104.dgn

9/11/2012

9:19:48 AM

rifem

F O

R U

M S

T U

D

IO

I

N N

E R

B E

L T B

U S

IN

E S

S C

E N

T E

R D

R

S T L

O U

IS

M O

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

SHEET

IDENTIFICATION

D A

T E

A P

P R

SHEET OF

fi

US Army Corps of Engineers

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

L O

U

IS

V

IL

L E D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K Y

GENERAL NOTES

KEY PLAN

KEY NOTES

GRAPHIC SCALE

8’0 4’ 16’

SCALE:1/8"=1’

F S

B A

Z

C L

A Y

C O C

O N

S T

R U

C T

IO

N

.1

.1

-W

Q R -0

-R -0

P -1

1 3

C O

N C

E P

T D

E S

IG

N S

U B

M

IT

T A

L .1

.0

.1

.0

R

E V

IS

E D C

H A

R R

E T

T E C

O N

C E

P T S

U B

M

IT

T A

L

IN

T

E R

IM

S

U B

M

IT

T A

L .1

.1

.2

.1

A F

R C

-A -1

.d g n

/1

/2

F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L

A R

M Y R

E S

E R

V E T

R A

IN

IN

G C

E N

T E

R W

IL

L O

W G

R O

V E N

A V

A L A

IR

S

T A

T

IO

N W

Q R -0

-C -0

H O

R S

H A

M P

A

C

O R

R E

C T

E D F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L .0

.1

.1

.1

C

E R

T

IF

IE

D F

IN

A L S

U B

M

IT

T A

L

B R

IC

E Z

IC

K U

H R

9’-4"

28’-9"11’-6"

2’-0"

6’-3"

/4

117A

121A

D

115.3

122A.4

116A.2

A .1

117B

B .1

B .2

102C.1

119A

118A.2

118A.1

.4

31’-7 1/8 "

M A

T C

H L

IN

E

A

-A -1

00-A-802

A5

00-A-402

00-A-403

00-A-511

2’-5"

.1

/4

/4

117C

B1.1 B1.2

9 9

S

5A

S

5A

S

2F

SW

S

2F

SW

T

2A

SW

T

2A

SW

T

2A

SW

S

1B

SW

@ DOOR

FRAME

S

1B

SW

PLAN

NORTH

TYP.

TYP.

CENTERED ON

CAGE WALL

CENTERED ON

CAGE WALL

T

2A

SW

T

2A

SW

S

1E

ABOVE

S

1A

ABOVE

S

1A

ABOVE

S

1A

S

1A

TYP.

TYP. TYP.

5’-6"3’-10"

117.2

/8

/2

/8

14’-0"

12’-0" 5’-7 1/8 " 12’-5 7/8 "

CONTROL JOINT, SEE DETAIL ON SHEET 00-A-501 FOR INFORMATION

CLASS 5 SAFE (GFGI)

PROVIDE 4x3 TACKBOARD WITH 1/4" ALUMINUM TRIM, SEE MOUNTING

HEIGHTS ELEVATION ON 00-G-003 FOR MORE INFORMATION

FIRE EXTINGUISHER (BRACKET MOUNTED)

BOLLARD - SEE TYPICAL DETAILS ON SHEET 00-A-521

COUNTER TOP AND BACKSPLASH - SEE DETAIL A1 ON SHEET 00-A-541

OUTLINE OF RADON SUMP BELOW SLAB - SEE SHEET 00-A-522 FOR DETAILS

LOCATION OF 6" DIA. RADON SUMP VENT (V.T.R.)

4’-0"W x 2’-0"D x 7’-3"H (5 HIGH) METAL SHELVING, SEE SPECIFICATIONS FOR

MORE INFORMATION

4" CONC. EQUIPMENT PAD

MIN. 225 S.F. DEDICATED RECYCLING AREA AS INDICATED BY DASHED LINE.

KNOX BOX - 54" A.F.F.

24’-0" 17’-2" 18’-2" 16’-0" 32’-0" 9’-4" 26’-4" 3’-4" 11’-0" 1’-8"

/8

/8

/8

1’-8"

40’-8"39’-8"1’-8"34’-2"26’-6"2’-0"6’-4"6’-4"

13’-2"

8 1/4 " 2’-0 1/2 "

58’-8 3/8 "

/4

/8

/8

/8

4’-5"3’-4"2’-0"

6 6.4 7 7.8 8 9 10

A

B

C

D

E

116B

VAULT

STAGING

116A

ARMORY

117D

OFFICE

117C

OFFICE

102B

MAIL SCAN

102C

MAIL

SCAN VESTIBULE

UNIT STOR

118A

ELEC

119A

ENT FACILITY

121A

MECH

117B

338 OFFICE

SUPPLY OFF

117A

HQ. 223

B

STAIR

1. ALL PARTITIONS ON THE FIRST FLOOR OF THE TRAINING BUILDING

TO BE TYPE 2A / S, SW. U.N.O.

2. ALL PARTITIONS ON THE SECOND FLOOR OF THE TRAINING

BUILDING TO BE TYPE 2A / T @ 10’-0", SW. U.N.O.

3. ALL PARTITIONS IN THE OMS / AMSA BUILDING TO BE TYPE 2A / S,

SW. U.N.O.

4. INSTALL A COAT HOOK ON THE WALL BEHIND THE DOOR IN ITS

OPENED POSITION IN THE SUPPLY OFFICE, FACILITY MANAGER,

FAMILY SUPPORT, REC / RET OFFICE, AND ALL PRIVATE OFFICES,

SEE THE TYPICAL MOUNTING HEIGHTS ELEVATION ON 00-G-003.

5. INSTALL POLYVINYL CORNER GUARDS 6" A.F.F. TO 6" BELOW THE

CEILING WHERE INDICATED ON THE PLAN FOR ALL PUBLIC

SPACES.

6. INSTALL STEEL CORNER GUARDS 6" A.F.F. TO 6" BELOW THE

CEILING WHERE INDICATED ON THE PLAN IN THE UNIT STORAGE

SPACE ONLY.

7. PROVIDE BLINDS AT ALL EXTERIOR WINDOWS.

8. SEE THE INTERIOR DRAWINGS FOR ALL FURNITURE AND

EQUIPMENT LAYOUTS.

9. DIMENSIONS ARE TO COLUMN LINES, FACE OF MASONRY, OR FACE

OF GYP.

10. REFER TO 00-G-003 FOR MATERIAL LEGEND OF HATCHED WALL TYPES.