AFE310-1.PDF
PDF 2 MB Posted
- Attached to
- PA 206 HORSHAM HVAC SYSTEMS REPAIRS
- Solicitation number
- W912BU24R0001
About this file
This file contains roofing details and specifications for repairs to the HVAC systems at the PA 206 Horsham facility. The solicitation is for mechanical, electrical, and plumbing services including repairs and replacements to the existing HVAC equipment and distribution systems. Bidders are required to have experience with federal facility repairs and working in occupied buildings. The award is a firm-fixed price contract issued by the Department of the Army Corps of Engineers Philadelphia District. The response deadline is not provided in the file.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W912BU24R0001 Amendment 0009_Cancellation.pdf | ||
| W912BU24R0001 Amendment 0005.pdf | ||
| 10-M-800.pdf | ||
| AF85D7-1.PDF | ||
| AFA040-1.PDF | ||
| 00-M-806.pdf | ||
| AF0F76-1.PDF | ||
| 00-MP-4.PDF | ||
| AF6B67-1.PDF | ||
| 10-M-803.pdf | ||
| AFDA0C-1.PDF | ||
| 00-M-201.pdf | ||
| AF7DA6-1.PDF | ||
| AF5B0D-1.PDF | ||
| AF4200-1.PDF | ||
| 10-MH-1.PDF | ||
| AF2EB8-1.PDF | ||
| AF7BD0-1.PDF | ||
| AF4273-1.PDF | ||
| 00-M-803.pdf | ||
| 10-M-801.pdf | ||
| 00-MP-2.PDF | ||
| AF1533-1.PDF | ||
| AF9D68-1.PDF | ||
| AFC2EA-1.PDF | ||
| AF2AEE-1.PDF | ||
| AFD99B-1.PDF | ||
| AF26AC-1.PDF | ||
| W912BU24R0001 Amendment 0004.pdf | ||
| AFFB36-1.PDF | ||
| 00-M-807.pdf | ||
| 00-M-808.pdf | ||
| AF9FDC-1.PDF | ||
| AF47CB-1.PDF | ||
| AFRC55-2.PDF | ||
| 00-M-802.pdf | ||
| AFFC3F-1.PDF | ||
| AFC8A7-1.PDF | ||
| AF8E75-1.PDF | ||
| AFD903-1.PDF | ||
| AF54B2-1.PDF | ||
| AFD078-1.PDF | ||
| 00-MH-1.PDF | ||
| AF0EF7-1.PDF | ||
| 00-MP-1.PDF | ||
| 00-M-805.pdf | ||
| 00-MH-4.PDF | ||
| AF377B-1.PDF | ||
| AF9D55-1.PDF | ||
| AFE9FE-1.PDF |
Show 40 more
Latest 50 of 102 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
00-A-531
A5 1 1/2" = 1’-0"
ROOF DETAIL
1 1/2" = 1’-0" C5
1 1/2" = 1’-0" D5
ROOF DETAIL
1 1/2" = 1’-0"
C4
ROOF DETAIL
1 1/2" = 1’-0"
A4
ROOF DETAIL
1 1/2" = 1’-0"
A3
ROOF DETAIL
1 1/2" = 1’-0"
A2
SCUPPER DETAIL
OVERFLOW SCUPPER DETAIL
A1 1 1/2" = 1’-0"
ROOF DETAIL @ MAIN ENTRY CANOPY
ROOF DETAIL @ MAIN ENTRY CANOPY
1 1/2" = 1’-0"
C1
D2 1 1/2" = 1’-0"
SCUPPER DETAIL @ MAIN ENTRY CANOPY
D1
DETAIL @ PARAPET CAP FLASHING
N.T.S.
1’ 2’0 6"
SCALE:1-1/2"=1’
1’ 2’0 6"
SCALE:1-1/2"=1’
1’ 2’0 6"
SCALE:1-1/2"=1’
1’ 2’0 6"
SCALE:1-1/2"=1’
1’ 2’0 6"
SCALE:1-1/2"=1’
1’ 2’0 6"
SCALE:1-1/2"=1’
1’ 2’0 6"
SCALE:1-1/2"=1’
1’ 2’0 6"
SCALE:1-1/2"=1’
1’ 2’0 6"
SCALE:1-1/2"=1’
1’ 2’0 6"
SCALE:1-1/2"=1’
REVISED AS-BUILT
F
IE
L D C
O N
D
IT
IO
N
T R
A
IN
IN
G C
E N
T E
R R
O O
F D
E T
A
IL
S
S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5500-A-531.dgn
9/11/2012
9:25:37 AM
rifem
F O
R U
M S
T U
D
IO
I
N N
E R
B E
L T B
U S
IN
E S
S C
E N
T E
R D
R
S T L
O U
IS
M O
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
fi
US Army Corps of Engineers
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S I
D
L O
U
IS
V
IL
L E D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K Y
F S
B A
Z
C L
A Y
C O C
O N
S T
R U
C T
IO
N
.1
.1
-W
Q R -0
-R -0
P -1
1 3
C O
N C
E P
T D
E S
IG
N S
U B
M
IT
T A
L .1
.0
.1
.0
R
E V
IS
E D C
H A
R R
E T
T E C
O N
C E
P T S
U B
M
IT
T A
L
IN
T
E R
IM
S
U B
M
IT
T A
L .1
.1
.2
.1
A F
R C
-A -5
.d g n
/1
/2
F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L
A R
M Y R
E S
E R
V E T
R A
IN
IN
G C
E N
T E
R W
IL
L O
W G
R O
V E N
A V
A L A
IR
S
T A
T
IO
N W
Q R -0
-C -0
H O
R S
H A
M P
A
C
O R
R E
C T
E D F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L .0
.1
.1
.1
C
E R
T
IF
IE
D F
IN
A L S
U B
M
IT
T A
L
B R
IC
E Z
IC
K U
H R
COL
T.O. WALL
VARIES
120’-0"
B.M.D.
T.O. STEEL
T.O. STEEL
114’-0"
T.O. SLAB
1’-7"
1’-8"
1’-7"
1’-8"
1’-8"
1’-8"
1’-7"
1’-8"
1’-8"
115’-4"
T.O. SILL
120’-0"
T.O. SILL
/2
/2
/2
/2
118’-3 3/4"
/2
/2
/2
/2
/2
00-A-532
A4
A4
A4 A4
00-A-532
B
B
6.4
D.1
112’-8"
110’-4"
B.O. STEEL
8"
6 1/4 "
/4
1’-0"
SIM. SIM.
B.O. SOFFIT
109’-6"
MORTAR NET
SCHEDULED BRICK
OR BLOCK
MTL. SCUPPER
SLEEVE
EDGE SEALANT
EDGE SEALANT
SEALANT
ROOF INSUL.
STL. DECK
METAL SCUPPER
SLEEVE W/ 24 GA
ONE PIECE
"PICTURE FRAME"
SEALED
AT EDGES
THRU WALL
FLASHING
METAL SCUPPER
SLEEVE W/ 24 GA
ONE PIECE
"PICTURE FRAME"
SEALED
AT EDGES
PREFIN. MTL DS.
EDGE SEALANT
MTL. SCUPPER
SLEEVE
EDGE SEALANT
MORTAR NET
THRU WALL
FLASHING
CONTINUOUS P.T. WOOD
BLOCKING W/ STAGGERED
ANCHORS @ 32" O.C.
NON-CORROSIVE SCREW
AND NEOPRENE WASHER
@ 24" O.C. AND END LAPS
FULLY ADHERED
MEMBRANE
FLASHING
FULLY ADHERED
MEMBRANE
FLASHING
FULLY ADHERED
MEMBRANE
FLASHING
PREFIN. MTL. COPING
SCHED. BRICK
RIGID INSUL.
EXTERIOR GYP.
SHEATHING
6" MTL. STUD WALL
W/ BATT INSUL.
ROOF INSUL.
STL. DECK
NON-CORROSIVE SCREW
AND NEOPRENE WASHER
@ 24" O.C. AND END LAPS
CONTINUOUS P.T. WOOD
BLOCKING W/ STAGGERED
ANCHORS @ 32" O.C.
PREFIN. MTL. COPING
SCHED. BRICK
RIGID INSUL.
EXTERIOR GYP.
SHEATHING
6" MTL. STUD WALL
W/ BATT INSUL.
THRU-WALL FLASHING
SELF-ADHERED COUNTER
FLASHING
MORTAR NET
ROOF INSUL.
STL. PLATE
SEE STRUCT.
THRU-WALL FLASHING
MORTAR NET
EXTERIOR GYP.
SHEATHING
ROOF INSUL.
SCHED. LAY-IN CEILING
ASSEMBLY
SOFFIT ASSEMBLY:
5/8" GYP. ON 3 5/8" MTL. STUDS
W/ SOUND BATTS
STL. BAR JOIST
SEE STRUCT.
6" MTL. STUD WALL
W/ BATT INSUL.
ROOF INSUL.
RIGID INSUL.
MORTAR NET
SCHED. BRICK
EXTERIOR GYP.
SHEATHING
RIGID INSUL.
SELF-ADHERED COUNTER
FLASHING
MORTAR NET
SCHED. BRICK
EXTERIOR GYP.
SHEATHING
ROOF INSUL.
STL. DECK
6" MTL. STUD WALL
W/ BATT INSUL.
6" MTL. STUD WALL
W/ BATT INSUL.
STL. BAR JOIST
SEE STRUCT.
STL. FRAMING MEMBER
SEE STRUCT.
SELF-ADHERED COUNTER
FLASHING
VENTED WEEPS
@ 24" O.C. (TYP.)
VENTED WEEPS
@ 24" O.C. (TYP.)
VENTED WEEPS
@ 24" O.C. (TYP.)
THRU-WALL FLASHING THRU-WALL FLASHING
VENTED WEEPS
@ 24" O.C. (TYP.)
NON-CORROSIVE SCREW
AND NEOPRENE WASHER
@ 24" O.C. AND END LAPS
CONTINUOUS P.T. WOOD
BLOCKING W/ STAGGERED
ANCHORS @ 32" O.C.
PREFIN. MTL. COPING
3 5/8" MTL. STUDS
MTL. DECKING
SEE STRUCTURAL
SOFFIT AND FASCIA TRIM
MTL. SOFFIT PANEL
1 1/2" Z-FURRING
SIM.
PREFIN. MTL. COPING
TERMINATION BAR WITH
SEALANT AT TOP OF BAR
SCHED. BRICK
EXTERIOR GYP.
SHEATHING
RIGID INSUL.
6" MTL. STUD WALL
W/ BATT INSUL.
ROOF INSUL.
ALUM. FRAME ENTRY
ASSEMBLY
MTL. SOFFIT PANEL
SOFFIT TRIM
1 1/2" Z-FURRING
STEEL FRAMING MEMBER.
PROVIDE TAPE AND SEALANT
WHERE PENETRATION OF AIR
AND WATER BARRIER OCCURS
METAL SCUPPER
SLEEVE W/ 24 GA
ONE PIECE
"PICTURE FRAME"
SEALED
AT EDGES
FULLY ADHERED
MEMBRANE
FLASHING
EDGE SEALANT
MTL. SCUPPER
SLEEVE
FULLY ADHERED
MEMBRANE
FLASHING
EDGE SEALANT
PREFIN. MTL.
CONDUCTOR
TURN COLLAR
DOWN 4" MIN.
PREFIN. MTL.
DOWN SPOUT.
TURN AND HOLD
TIGHT TO EAST
SIDE OF CANOPY
COLUMN BELOW
PREFIN. MTL. COPING
NON-CORROSIVE SCREW
AND NEOPRENE WASHER
@ 24" O.C. AND END LAPS
SCUPPER BEYOND
SEE D2/00-A-531
SCHEDULED BRICK
CONTINUOUS P.T. WOOD
BLOCKING W/ STAGGERED
ANCHORS @ 32" O.C.
PREFIN. MTL. COPING
CONT. SEALANT AT
TOP AND SIDES
SCHEDULED PARAPET
ASSEMBLY
PREFIN. MTL. COUNTER
FLASHING PROVIDE REGLET
CONNECTION IN MASONRY
A.M.B.S.
A.M.B.S.
A.M.B.S.
OSB SHEATHING
A.M.B.S. - EXTEND OVER
TOP OF MTL STUD TO 6"
BELOW WOOD BLOCKING
A.M.B.S.
A.M.B.S.
A.M.B.S. - EXTEND OVER
TOP OF MTL STUD TO 6"
BELOW WOOD BLOCKING
A.M.B.S.
SELF-ADHERED COUNTER
FLASHING
MTL. WALL PANEL
MTL. WALL PANEL
EPDM ROOF MEMBRANE
EPDM ROOF MEMBRANE
EPDM ROOF MEMBRANE
EPDM ROOF
MEMBRANE
EPDM ROOF MEMBRANE
EPDM ROOF MEMBRANE
EPDM ROOF MEMBRANE
CMU BLOCK - GROUT SOLID CMU BLOCK - GROUT SOLID
EPDM ROOF MEMBRANE
EPDM ROOF MEMBRANE
FULLY ADHERED EPDM MEMBRANE
EXTEND OVER PARAPET TOP
TO 1/2" BELOW WOOD
BLOCKING
FULLY ADHERED
EPDM MEMBRANE
FLASHING
FULLY ADHERED EPDM MEMBRANE
EXTEND OVER PARAPET TOP
TO 1/2" BELOW WOOD
BLOCKING
FULLY ADHERED
EPDM MEMBRANE
FULLY ADHERED
EPDM MEMBRANE
FULLY ADHERED EPDM MEMBRANE
FULLY ADHERED
EPDM MEMBRANE
FULLY ADHERED EPDM MEMBRANE
EXTEND OVER PARAPET TOP
TO 1/2" BELOW WOOD
BLOCKING
FULLY ADHERED EPDM MEMBRANE
EXTEND OVER PARAPET TOP
TO 1/2" BELOW WOOD
BLOCKING
1" RIGID INSUL. ADHERED W/
ROOFING ADHESIVE
1" RIGID INSUL. ADHERED W/
ROOFING ADHESIVE
8"
TREATED WOOD
BLOCKING AT
SCUPPER ONLY
TREATED PLYWOOD
3-2X6 TREATED
WD BLOCKING
AT SCUPPER
ONLY
TREATED
PLYWOOD
1’-0"
PREFIN. MTL. CONDUCTOR
TURN COLLAR DOWN 4" MIN.
TREATED PLYWOOD
2X6 TREATED
WOOD BLOCKING
AT SCUPPER ONLY
5/8" GYP BD
File details come from the government source that posted it. Updated .