AFD13B-1.PDF
PDF 581 KB Posted
- Attached to
- PA 206 HORSHAM HVAC SYSTEMS REPAIRS
- Solicitation number
- W912BU24R0001
About this file
This document contains floor plans and notes for the Army Reserve Training Center Willow Grove Naval Air Station in Horsham, Pennsylvania. Key details include specifications for partition types and locations throughout the facility, notes regarding installation of coat hooks, corner guards, blinds, and reference to other drawings for furniture and equipment layouts. Dimensions are shown from column lines, faces of masonry or gypsum board. A material legend for hatched wall types is referenced.
The related federal contract opportunity is for HVAC system repairs at PA 206 Horsham. The solicitation number is W912BU24R0001 and was issued by the Department of the Army Corps of Engineers Engineering District Philadelphia as a Special Notice. No further product, service, pricing or schedule details are provided.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W912BU24R0001 Amendment 0009_Cancellation.pdf | ||
| W912BU24R0001 Amendment 0005.pdf | ||
| 10-M-800.pdf | ||
| AF85D7-1.PDF | ||
| AFA040-1.PDF | ||
| 00-M-806.pdf | ||
| AF0F76-1.PDF | ||
| 00-MP-4.PDF | ||
| AF6B67-1.PDF | ||
| 10-M-803.pdf | ||
| AFDA0C-1.PDF | ||
| 00-M-201.pdf | ||
| AF7DA6-1.PDF | ||
| AF5B0D-1.PDF | ||
| AF4200-1.PDF | ||
| 10-MH-1.PDF | ||
| AF2EB8-1.PDF | ||
| AF7BD0-1.PDF | ||
| AF4273-1.PDF | ||
| 00-M-803.pdf | ||
| 10-M-801.pdf | ||
| 00-MP-2.PDF | ||
| AF1533-1.PDF | ||
| AF9D68-1.PDF | ||
| AFC2EA-1.PDF | ||
| AF2AEE-1.PDF | ||
| AFD99B-1.PDF | ||
| AF26AC-1.PDF | ||
| W912BU24R0001 Amendment 0004.pdf | ||
| AFFB36-1.PDF | ||
| 00-M-807.pdf | ||
| 00-M-808.pdf | ||
| AF9FDC-1.PDF | ||
| AF47CB-1.PDF | ||
| AFRC55-2.PDF | ||
| 00-M-802.pdf | ||
| AFFC3F-1.PDF | ||
| AFC8A7-1.PDF | ||
| AF8E75-1.PDF | ||
| AFD903-1.PDF | ||
| AF54B2-1.PDF | ||
| AFD078-1.PDF | ||
| 00-MH-1.PDF | ||
| AF0EF7-1.PDF | ||
| 00-MP-1.PDF | ||
| 00-M-805.pdf | ||
| 00-MH-4.PDF | ||
| AF377B-1.PDF | ||
| AF9D55-1.PDF | ||
| AFE9FE-1.PDF |
Show 40 more
Latest 50 of 102 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
10-A-102
1/8" = 1’ 0" A4
FLOOR PLAN - WEST
AS-BUILT
O M
S A
M S
A F
L O
O R P
L A
N W
E S
T
S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5510-A-102.dgn
9/11/2012
9:32:09 AM
rifem
F O
R U
M S
T U
D
IO
I
N N
E R
B E
L T B
U S
IN
E S
S C
E N
T E
R D
R
S T L
O U
IS
M O
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
fi
US Army Corps of Engineers
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S I
D
L O
U
IS
V
IL
L E D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K Y
GENERAL NOTES
KEY PLAN
KEY NOTES
GRAPHIC SCALE
8’0 4’ 16’
SCALE:1/8"=1’
F S
B A
Z
C L
A Y
C O C
O N
S T
R U
C T
IO
N
.1
.1
-W
Q R -0
-R -0
P -1
1 3
C O
N C
E P
T D
E S
IG
N S
U B
M
IT
T A
L .1
.0
.1
.0
R
E V
IS
E D C
H A
R R
E T
T E C
O N
C E
P T S
U B
M
IT
T A
L
IN
T
E R
IM
S
U B
M
IT
T A
L .1
.1
.2
.1
A F
R C
-A -1
.d g n
/1
/2
F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L
A R
M Y R
E S
E R
V E T
R A
IN
IN
G C
E N
T E
R W
IL
L O
W G
R O
V E N
A V
A L A
IR
S
T A
T
IO
N W
Q R -0
-C -0
H O
R S
H A
M P
A
C
O R
R E
C T
E D F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L .0
.1
.1
.1
C
E R
T
IF
IE
D F
IN
A L S
U B
M
IT
T A
L
B R
IC
E Z
IC
K U
H R
M A
T C
H L
IN
E
A
-A -1
PLAN
NORTH
A .0
150A.02150A.03150A.04150A.05
150A.06
150A.07
150A.08 150A.09 150A.10 150A.11
A .1
02HI
LO
02HI
LO
02HI
LO
02HI
LO
1’-0"
3’-4"2’-0"16’-0"4’-0"16’-0"4’-0"16’-0"4’-0"16’-0"4’-4"2’-0"
TRENCH DRAIN - SLOPE FLOOR TO DRAIN
BOLLARD - SEE TYPICAL DETAILS ON SHEET 10-A-521
2 2
2 2
1 1
2 2
2 2
2 2
3’-4"2’-0"16’-0"4’-0"16’-0"
2’-0"2’-0"
16’-0" 2’-0"2’-0"
16’-0"4’-4"2’-0"
1 1.5 2 3
321.51
E
D
C.5
C
B
A
B.5
150A
WORK BAYS
1. ALL PARTITIONS ON THE FIRST FLOOR OF THE TRAINING BUILDING
TO BE TYPE 2A / S, SW. U.N.O.
2. ALL PARTITIONS ON THE SECOND FLOOR OF THE TRAINING
BUILDING TO BE TYPE 2A / T @ 10’-0", SW. U.N.O.
3. ALL PARTITIONS IN THE OMS / AMSA BUILDING TO BE TYPE 2A / S,
SW. U.N.O.
4. INSTALL A COAT HOOK ON THE WALL BEHIND THE DOOR IN ITS
OPENED POSITION IN THE SUPPLY OFFICE, FACILITY MANAGER,
FAMILY SUPPORT, REC / RET OFFICE, AND ALL PRIVATE OFFICES,
SEE THE TYPICAL MOUNTING HEIGHTS ELEVATION ON 00-G-003.
5. INSTALL POLYVINYL CORNER GUARDS 6" A.F.F. TO 6" BELOW THE
CEILING WHERE INDICATED ON THE PLAN FOR ALL PUBLIC
SPACES.
6. INSTALL STEEL CORNER GUARDS 6" A.F.F. TO 6" BELOW THE
CEILING WHERE INDICATED ON THE PLAN IN THE UNIT STORAGE
SPACE ONLY.
7. PROVIDE BLINDS AT ALL EXTERIOR WINDOWS.
8. SEE THE INTERIOR DRAWINGS FOR ALL FURNITURE AND
EQUIPMENT LAYOUTS.
9. DIMENSIONS ARE TO COLUMN LINES, FACE OF MASONRY, OR FACE
OF GYP.
10. REFER TO 00-G-003 FOR MATERIAL LEGEND OF HATCHED WALL TYPES.