AF7200-1.PDF
PDF 729 KB Posted
- Attached to
- PA 206 HORSHAM HVAC SYSTEMS REPAIRS
- Solicitation number
- W912BU24R0001
About this file
This document contains architectural drawings and details for door, window, and storefront installations. The drawings depict metal and aluminum framed doors and windows, masonry details, and insulation requirements.
The related federal contract opportunity is solicitation number W912BU24R0001 for HVAC systems repairs at the PA 206 Horsham facility. The solicitation was issued by the Department of the Army Corps of Engineers Engineering District Philadelphia as a special notice. The opportunity involves repair of HVAC systems but provides no further details on requirements, response dates, or place of performance.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W912BU24R0001 Amendment 0009_Cancellation.pdf | ||
| W912BU24R0001 Amendment 0005.pdf | ||
| 10-M-800.pdf | ||
| AF85D7-1.PDF | ||
| AFA040-1.PDF | ||
| 00-M-806.pdf | ||
| AF0F76-1.PDF | ||
| 00-MP-4.PDF | ||
| AF6B67-1.PDF | ||
| 10-M-803.pdf | ||
| AFDA0C-1.PDF | ||
| 00-M-201.pdf | ||
| AF7DA6-1.PDF | ||
| AF5B0D-1.PDF | ||
| AF4200-1.PDF | ||
| 10-MH-1.PDF | ||
| AF2EB8-1.PDF | ||
| AF7BD0-1.PDF | ||
| AF4273-1.PDF | ||
| 00-M-803.pdf | ||
| 10-M-801.pdf | ||
| 00-MP-2.PDF | ||
| AF1533-1.PDF | ||
| AF9D68-1.PDF | ||
| AFC2EA-1.PDF | ||
| AF2AEE-1.PDF | ||
| AFD99B-1.PDF | ||
| AF26AC-1.PDF | ||
| W912BU24R0001 Amendment 0004.pdf | ||
| AFFB36-1.PDF | ||
| 00-M-807.pdf | ||
| 00-M-808.pdf | ||
| AF9FDC-1.PDF | ||
| AF47CB-1.PDF | ||
| AFRC55-2.PDF | ||
| 00-M-802.pdf | ||
| AFFC3F-1.PDF | ||
| AFC8A7-1.PDF | ||
| AF8E75-1.PDF | ||
| AFD903-1.PDF | ||
| AF54B2-1.PDF | ||
| AFD078-1.PDF | ||
| 00-MH-1.PDF | ||
| AF0EF7-1.PDF | ||
| 00-MP-1.PDF | ||
| 00-M-805.pdf | ||
| 00-MH-4.PDF | ||
| AF377B-1.PDF | ||
| AF9D55-1.PDF | ||
| AFE9FE-1.PDF |
Show 40 more
Latest 50 of 102 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
00-A-702
B4 3" = 1’-0"
H.M. DOOR HEAD DETAIL
H.M. DOOR JAMB DETAIL
3" = 1’-0"
C4
3" = 1’-0" B3
C3 3" = 1’-0"
ALUM. FRAME DOOR JAMB DETAIL
ALUM. FRAME DOOR HEAD DETAIL
ALUM. FRAME DOOR SILL DETAIL
A3
3" = 1’-0" A4
3" = 1’-0"
ALUM. FRAME WINDOW SILL DETAIL
SCALE: 3"=1’
3" 6" 9" 12"
SCALE: 3"=1’
3" 6" 9" 12"
SCALE: 3"=1’
3" 6" 9" 12"
SCALE: 3"=1’
3" 6" 9" 12"
SCALE: 3"=1’
3" 6" 9" 12" 0
SCALE: 3"=1’
3" 6" 9" 12"
AS-BUILT
T R
A
IN
IN
G C
E N
T E
R D
O O
R
W
IN
D O
W A
N D S
T O
R E
F R
O N
T D
E T
A
IL
S
S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5500-A-702.dgn
9/11/2012
9:26:50 AM
rifem
F O
R U
M S
T U
D
IO
I
N N
E R
B E
L T B
U S
IN
E S
S C
E N
T E
R D
R
S T L
O U
IS
M O
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
fi
US Army Corps of Engineers
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S I
D
L O
U
IS
V
IL
L E D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K Y
F S
B A
Z
C L
A Y
C O C
O N
S T
R U
C T
IO
N
.1
.1
-W
Q R -0
-R -0
P -1
1 3
C O
N C
E P
T D
E S
IG
N S
U B
M
IT
T A
L .1
.0
.1
.0
R
E V
IS
E D C
H A
R R
E T
T E C
O N
C E
P T S
U B
M
IT
T A
L
IN
T
E R
IM
S
U B
M
IT
T A
L .1
.1
.2
.1
A F
R C
-A -7
.d g n
/1
/2
F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L
A R
M Y R
E S
E R
V E T
R A
IN
IN
G C
E N
T E
R W
IL
L O
W G
R O
V E N
A V
A L A
IR
S
T A
T
IO
N W
Q R -0
-C -0
H O
R S
H A
M P
A
C
O R
R E
C T
E D F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L .0
.1
.1
.1
C
E R
T
IF
IE
D F
IN
A L S
U B
M
IT
T A
L
B R
IC
E Z
IC
K U
H R
SCHEDULED H.M.
DOOR AND FRAME
CMU BLOCK WITH
FINISHED CORNER
CMU BOND BEAM
A.M.B.S.
BRICK VENEER
GALV. STL. ANGLE
LINTEL - PT.
VENTED WEEPS @
24" O.C.
SELF ADHERING
MEMBRANE
FLASHING.
EXTEND 1" PAST FACE
OF BRICK. TRIM
FLUSH AT
COMPLETION.
ALUM. DOOR /
FRAME AS
SCHEDULED
MTL. STUD BOX
BEAM - FILL W/
INSUL.
MORTAR NET
TAPEABLE J-MOLD &
SEALANT
A.M.B.S.
BRICK VENEER
ALUM. DOOR /
FRAME AS
SCHEDULED
DOUBLE MTL. STUD -
FILL W/ INSUL.
CONT. SEALANT W/
BACKER ROD INT. &
EXT.
5/8" GYP. BD. ON 6"
MTL. STUD
BATT INSUL.
TAPEABLE J-MOLD &
SEALANT
2" RIGID INSUL.
ADA COMPLIANT
THRESHOLD IN FULL
MASTIC BED
ALUM. DOOR AS
SCHEDULED
FACE OF EXTERIOR
WALL BEYOND
GLAZING AS
SCHEDULED
BRICK VENEER
RETURN
2" RIGID INSUL.
CONT. SEALANT W/
BACKER ROD INT. &
EXT.
EXTERIOR SHEATHING
5/8" GYP. BD. ON 6"
MTL. STUD
BATT INSUL.
A.M.B.S.
BRICK VENEER
CONT. SEALANT W/
BACKER ROD INT. &
EXT.
2" RIGID INSUL.
BRICK VENEER
RETURN
A.M.B.S.
BRICK VENEER
GALV. STL. ANGLE
LINTEL - PT.
VENTED WEEPS @
24" O.C.
SELF ADHERING
MEMBRANE
FLASHING.
EXTEND 1" PAST FACE
OF BRICK. TRIM
FLUSH AT
COMPLETION.
MORTAR NET
NOTE: DO NOT
ANCHOR INTO
MASONRY LINTEL
2" RIGID INSUL.
CONT. SEALANT W/
BACKER ROD INT. &
EXT.
EXTERIOR SHEATHING
SCHEDULED H.M.
DOOR AND FRAME
MASONRY JAMB
ANCHORS
(3) PER SIDE
NOTE: DO NOT
ANCHOR INTO
MASONRY LINTEL
MASONRY ANCHOR
MASONRY ANCHOR
SILL PAN SET IN
MASTIC
SCHEDULED ALUM.
FRAME WINDOW
FACE OF EXTERIOR
WALL BEYOND
RIGID INSULATION
CONC. WALK
LEAN CONC. FILL
FROST BLOCK
SEALANT AND 1/2"
EXPANSION MAT
EDGE OF SLAB
BEYOND
RIGID INSULATION
CONC. WALK
LEAN CONC. FILL
FROST BLOCK
SEALANT AND 1/2"
EXPANSION MAT
EDGE OF SLAB
BEYOND
6 1/2 "
6 1/2 "
6 1/2 "
2 1/2 " 2 1/2 "
GROUT AND
REINFORCE
CORE
File details come from the government source that posted it. Updated .