AF69FD-1.PDF
PDF 2 MB Posted
- Attached to
- PA 206 HORSHAM HVAC SYSTEMS REPAIRS
- Solicitation number
- W912BU24R0001
About this file
This document contains construction drawings and general notes for repairs to HVAC systems at the PA 206 Horsham facility. Key details include specifications for repairs to HVAC systems in buildings 5500, 5510, and 5520, with building ground floor elevations provided. Standard notes cover conforming to building codes, verifying dimensions before proceeding with work, and coordinating with other trades for rough-in locations. Product and installation requirements include partition types, mounting heights for devices, and pre-rough in coordination meetings. The related federal contract opportunity is solicitation number W912BU24R0001 from the Department of the Army Corps of Engineers Engineering District Philadelphia for HVAC system repairs at the Army Reserve Training Center Willow Grove Naval Air Station in Horsham, PA.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W912BU24R0001 Amendment 0009_Cancellation.pdf | ||
| W912BU24R0001 Amendment 0005.pdf | ||
| 10-M-800.pdf | ||
| AF85D7-1.PDF | ||
| AFA040-1.PDF | ||
| 00-M-806.pdf | ||
| AF0F76-1.PDF | ||
| 00-MP-4.PDF | ||
| AF6B67-1.PDF | ||
| 10-M-803.pdf | ||
| AFDA0C-1.PDF | ||
| 00-M-201.pdf | ||
| AF7DA6-1.PDF | ||
| AF5B0D-1.PDF | ||
| AF4200-1.PDF | ||
| 10-MH-1.PDF | ||
| AF2EB8-1.PDF | ||
| AF7BD0-1.PDF | ||
| AF4273-1.PDF | ||
| 00-M-803.pdf | ||
| 10-M-801.pdf | ||
| 00-MP-2.PDF | ||
| AF1533-1.PDF | ||
| AF9D68-1.PDF | ||
| AFC2EA-1.PDF | ||
| AF2AEE-1.PDF | ||
| AFD99B-1.PDF | ||
| AF26AC-1.PDF | ||
| W912BU24R0001 Amendment 0004.pdf | ||
| AFFB36-1.PDF | ||
| 00-M-807.pdf | ||
| 00-M-808.pdf | ||
| AF9FDC-1.PDF | ||
| AF47CB-1.PDF | ||
| AFRC55-2.PDF | ||
| 00-M-802.pdf | ||
| AFFC3F-1.PDF | ||
| AFC8A7-1.PDF | ||
| AF8E75-1.PDF | ||
| AFD903-1.PDF | ||
| AF54B2-1.PDF | ||
| AFD078-1.PDF | ||
| 00-MH-1.PDF | ||
| AF0EF7-1.PDF | ||
| 00-MP-1.PDF | ||
| 00-M-805.pdf | ||
| 00-MH-4.PDF | ||
| AF377B-1.PDF | ||
| AF9D55-1.PDF | ||
| AFE9FE-1.PDF |
Show 40 more
Latest 50 of 102 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
00-G-003
G E
N E
R A
L N
O T
E S S
Y M
B O
L K
E Y
M A
T E
R
IA
L P
A T
T E
R N
S
A B
B R
E V
IA
T
IO
N S
T Y
P
M O
U N
T
IN
G H
E
IG
H T S
AS-BUILT
S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\General\AFRC5500-G-003.dgn
9/11/2012
9:17:49 AM
rifem
F O
R U
M S
T U
D
IO
I
N N
E R
B E
L T B
U S
IN
E S
S C
E N
T E
R D
R
S T L
O U
IS
M O
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
fi
US Army Corps of Engineers
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S I
D
L O
U
IS
V
IL
L E D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K Y
F S
B A
Z
C L
A Y
C O C
O N
S T
R U
C T
IO
N
.1
.1
-W
Q R -0
-R -0
P -1
1 3
C O
N C
E P
T D
E S
IG
N S
U B
M
IT
T A
L .1
.0
.1
.0
R
E V
IS
E D C
H A
R R
E T
T E C
O N
C E
P T S
U B
M
IT
T A
L
IN
T
E R
IM
S
U B
M
IT
T A
L .1
.1
.2
.1
A F
R C
-G
-0 .d g n
/1
/2
F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L
A R
M Y R
E S
E R
V E T
R A
IN
IN
G C
E N
T E
R W
IL
L O
W G
R O
V E N
A V
A L A
IR
S
T A
T
IO
N W
Q R -0
-C -0
H O
R S
H A
M P
A
C
O R
R E
C T
E D F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L .0
.1
.1
.1
C
E R
T
IF
IE
D F
IN
A L S
U B
M
IT
T A
L
B R
IC
E Z
IC
K U
H R
6"
4"
6" 6"
8"
6"
1’-8"1’-8" 1’-8" 1’-8"
18"
M A
X
36" MIN.
42" MIN.
54" MIN.
12" MAX.
42" MIN.
15" MIN.
" 4
M A
X
M A
X
M A
X
15"
MIN.
8"
MIN.
17"
MIN. 3
M A
X
M A
X
36" MAX.
M
IN
9" MAX.
/2
M
IN
M A
X
M A
X
24" MAX.
17"-19"
M
IN
M A
X
M A
X
M A
X
30" MIN.
CLEAR
X
XX-A-XXX
ROOM NAME
C.L
C.L
X
X
M A
X
40"
M A
X
1’-0"
2’-0"
6" 6"
SHELF TOWEL
BAR
SOAP
DISPENSER
CLOTHES
HOOK
PAPER DISPENSER/
WASTE RECEPTACLE
(LARGE CAPACITY)
DOUBLE FOUNTAIN
(SIDE)
DOUBLE FOUNTAIN
(FRONT)
ELECTRICAL/
TELEPHONE OUTLET
ABOVE COUNTER
FIRE
EXTINGUISHER
CABINET
VISUAL
ALARM/
STROBE
DUPLEX RECEP./
COMM. OUTLET
PEEP
HOLE
COAT
HOOK
ELEVATOR
SIGNAGE
DOOR SIGNAGE/
CARD READER
LIGHT SWITCH / THERMOSTAT
SIDE REACH
(PREFERRED)
LIGHT SWITCH /
THERMOSTAT
FRONT REACH
STANDARD
SHOWER
(SIDES)
STANDARD
SHOWER
(BACK)
TOILET GRAB BAR TOILET/GRAB BAR URINAL LAVATORY /
MIRROR
(FRONT)
LAVATORY /
MIRROR
(SIDE)
TISSUE DISPENSER/
NAPKIN DISPOSAL
PAPER/TISSUE DISPENSER/
NAPKIN DISPOSAL UNIT
DOOR
SIGNAGE
CARD
READER
ACCESSIBLE
NOTE:
FRONT-REACH REQUIRES 30" X 48" CLEAR FLOOR SPACE IN
FRONT OF FIXTURE. SIDE-REACH REQUIRES 48" X 30" CLEAR
FLOOR SPACE IN FRONT OF FIXTURE.
T O
P O
F S
P O
U T
T O
P O
F S
P O
U T
T O
P O
F C
O N
T R
O L
T O
P O
F C
O N
T R
O L
B O
T T
O M O
F L
E N
S
1.
2.
3.
4.
5.
6.
7.
8.
9.
ABBREVIATIONS
TYPICAL MOUNTING HEIGHTS
LF
LH
LKR
LP
M
MA
MAS
MATL
MAX
MB
MECH
MFR
MH
MIN
MISC
MM
MO
MTD
MTL
N
NIC
NO
NOM
NTS
OA
OC
OD
OH
OHD
OPNG
OPP
OPP HD
ORD
OPT
ORIG
OTS
OZ
PARTN
PC
PERF
PJ
PL
PLAS
P LAM
PLG
PLYWD
PNL
PR
PREFAB
PRELIM
PROJ
PSF
PSI
PT
PTD
QT
QTR
R R/A
RAD
RB
RD
REF
REINF
RF
REFRG
REQD
RET
REV
RH
RM
RO
RTU
RV
S S/A
SAB
SAN
SD
SF
SHR
SHT
SIM
SM
SNR
SPEC(S)
SPKR
SQ
SS
ST
STD
STL
STOR
STRL
STRUCT
SUSP
SYM
SYS
T T&G
TELE
TEM
TEMP
TERR
THK
THRU
TO
TPH
TSS
TSTL
TU
TV
TW
TYP
UH
UNFIN
UL
UNO
VB
VENT
VERT
VEST
VIF
VP
VWC
LINEAR FEET
LEFT HAND
LOCKER
LOW POINT
METER
MARBLE
MASONRY
MATERIAL
MAXIMUM
MARKER BOARD OR MOP BASIN
MECHANICAL
MANUFACTURER
MANHOLE
MINIMUM
MISCELLANEOUS
MILLIMETER
MASONRY OPENING
MOUNTED
METAL
NORTH
NOT IN CONTRACT
NUMBER
NOMINAL
NOT TO SCALE
OVER ALL
ON CENTER
OUTSIDE DIAMETER
OVERHEAD
OVERHEAD DOOR
OPENING
OPPOSITE
OPPOSITE HAND
OVERFLOW ROOF DRAIN
OPTIONAL
ORIGINAL
OPEN TO STRUCTURE
OUNCE
PARTITION
PRECAST
PERFORATED
PANEL JOINT
PLATE
PLASTER
PLASTIC LAMINATE
PLUMBING
PLYWOOD
PANEL
PAIR
PREFABRICATED
PRELIMINARY
PROJECT
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
POINT
PAINTED OR PAPER TOWEL
DISPENSER
QUARRY TILE
QUARTER
RISER
RETURN AIR
RADIUS
RESILIENT BASE
ROOF DRAIN
REFERENCE
REINFORCED (ING)
RESILIENT FLOORING
REFRIGERATOR
REQUIRED
RETAINING
REVISION
RIGHT HAND
ROOM
ROUGH OPENING
ROOF TOP UNIT
ROOF VENT
SOUTH
SUPPLY AIR
SOUND ATTENUATION BLANKET
SANITARY
SMOKE DETECTOR
SQUARE FEET
SHOWER
SHEET
SIMILAR
SQUARE METER
SANITARY NAPKIN RECEPTACLE
SPECIFICATION(S)
SPEAKER
SQUARE
STAINLESS STEEL
STREET
STANDARD
STEEL
STORAGE
STRUCTURAL
STRUCTURE
SUSPENDED
SYMMETRICAL
SYSTEM
TREAD
TONGUE & GROOVE
TELEPHONE
TEMPERED
TEMPORARY
TERRAZZO
THICK
THROUGH
TOP OF
TOILET PAPER HOLDER
TOP STRUCTURAL SLAB
TOP OF STEEL
TILT-UP
TELEVISION
TOP OF WALL
TYPICAL
UNIT HEATER
UNFINISHED
UNDERWRITER’S LABORATORY
UNLESS NOTED OTHERWISE
VAPOR BARRIER
VENTILATION
VERTICAL
VESTIBULE
VERIFY IN FIELD
VENEER PLASTER
VINYL WALL COVERING
GENERAL NOTESSYMBOL KEYMATERIAL PATTERNS
EARTH
GRAVEL /
BALLAST
STEEL
ALUMINUM
FINISH
LUMBER
SHIM
CONCRETE
CUT STONE /
PRE-CAST
CONCRETE
MASONRY
UNITS
BRICK
PLYWOOD
RIGID
INSUL.
BATT
INSUL.
FIRE
SAFING
MARBLE /
GRANITE
WOOD
BLOCKING
DETAIL KEY
ELEVATION KEY
WALL SECTION KEY
BUILDING SECTION KEY
REVISION CLOUD
NORTH ARROW
COLUMN GRID
Detail #
Sheet #
Sheet #
Sheet #
Detail #
Sheet #
Section #
Elevation#
Project North
True North
TAG KEY
ROOM TAG
WALL TAG
(PARTITION TYPE)
KEY NOTE
ACCESSORY TAG
DOOR TAG
WINDOW TAG
CEILING TAG
0’-0"
ELECTRIC
HAND
DRYER
LOUVER TAG
REFER TO SHEETS 00-G-101 AND 00-G-102 FOR CODE DATA & LIFE SAFETY
INFORMATION.
WORK SHALL CONFORM TO ALL STATE AND LOCAL APPLICABLE BUILDING CODES,
REGULATIONS AND ORDINANCES HAVING JURISDICTION.
BUILDING GROUND FINISH FLOOR ELEVATION IS 306.00’ = 100’-0" FOR BLDG 5500
BUILDING GROUND FINISH FLOOR ELEVATION IS 312.00’ = 100’-0" FOR BLDG 5510
BUILDING GROUND FINISH FLOOR ELEVATION IS 316.00’ = 100’-0" FOR BLDG 5520
SEE SHEET ##-A-501 FOR PARTITION TYPES AND TYPICAL PARTITION NOTES.
SEE SHEET 00-G-003 FOR TYPICAL MOUNTING LOCATIONS AND HEIGHTS OF DEVICES.
MECHANICAL AND ELECTRICAL SUB-CONTRACTORS TO SCHEDULE A PRE-ROUGH IN
MEETING WITH THE ARCHITECT TO COORDINATE AESTHETIC LOCATION OF OUTLET,
SWITCH, DATA, THERMOSTAT, PANEL, HORN, STROBE, AND EMERGENCY LIGHTS, ETC.
ROUGH-INS.
CONTRACTOR SHALL VERIFY ALL CONDITIONS , DIMENSIONS, AND SHALL
COORDINATE WITH TRADES IN LAYOUT OF HIS WORK. THE ALIGNMENT IN
COORDINATION OF HIS WORK AND OTHER ADJACENT WORK IS OF PRIMARY
IMPORTANCE AND SHALL TAKE PRECEDENCE OVER DIMENSIONS. CONTRACTOR
SHALL LAYOUT AND VERIFY HIS WORK TO ENSURE PROPER ALIGNMENT AND FIT.
CONTRACTOR SHALL IMMEDIATELY REPORT ANY DISCREPANCIES TO HIS
SUPERINTENDENT AND THE ARCHITECT BEFORE PROCEEDING, OR PROCEED AT
CONTRACTOR’S OWN RISK.
CONTRACTOR SHALL WORK FROM ESTABLISHED POINTS AND LINES, ESTABLISH AND
MAINTAIN MARKERS FOR LINES AND LEVELS OF WORK. DO NOT SCALE DRAWINGS,
CALCULATE DIMENSIONS AND MEASURE FOR LAYOUT OF WORK.
CONTRACTOR SHALL REPORT IMMEDIATELY ANY DISCREPANCIES TO HIS
SUPERINTENDENT AND THE ARCHITECT BEFORE PROCEEDING, OR PROCEED AT
CONTRACTOR’S OWN RISK.
THE WORD ’ALIGN’ AS IN THESE DOCUMENTS SHALL SUPERSEDE ANY DIMENSIONAL
INFORMATION SHOWN. IF A DISCREPANCY OCCURS, NOTIFY THE SUPERINTENDENT
AND ARCHITECT IMMEDIATELY.
REFER TO STRUCTURAL DRAWINGS FOR ALL JOINTS IN FLOOR SLAB(S).
NON-
ACCESSIBLE
CL
PLAN
NORTH
TACKBOARD CHAIR RAILMARKER BOARD W/ 2"
MAP RAIL ON TOP AND
2" TRAY ON BOTTOM
ENCLOSED
TACKBOARD
MAP RAIL
MAX. FRONT
REACH TO TOP OF
CONTROL
MAX. SIDE REACH
TO TOP OF
CONTROL
TOWEL
HOOK
INTERIOR
SIGNAGE TYPE
DD1
INTERIOR
SIGNAGE TYPE
CC2
C L
EXTERIOR
SIGNAGE TYPE
B5
INTERIOR / EXTERIOR
SIGNAGE TYPE
BB2,BB7
A/C
ACOUS
ACT
AFF
AFG
AHU
AL
ALT
A.M.B.S.
AMT
AP
APPROX
ARCH
A/V
BD
BLDG
BLK
BM
BMD
BO
BOT
BRG
BSMT
CAB(S)
CB
C/C
CG
CI
CJ
CLG
CLO
CLR
CM
CMP
CMU
CO
COL
CONC
CONSTR
CONT
CONTR
CPT
CT
CTR
CTSK
DBL
DEG
DEPT
DTL
DIA
DIAG
DIM
DN
DR
DS
DWG(S)
E
EA
EIFS
EJ
EL
ELEC
ELEV
ENCL
ENGR
EQ
EQUIP
ESMT
EWC
EXH
EXIST
EXP
EXT
FA
FCU
FD
FDN
FE
FEC
FF
FHC
FIN
FL
FLR
FT
FTG
FUT
FWC
GA
GALV
GB
GC
GEN
GFB
GFCI
GFGI
GFRC
GFRG
GL
GND
GWB
H
HB
HC
HDCP
HD
HDW
HM
HORIZ
HP
HGT
HTR
HWH
HVAC
ID
IN
INCL
INFO
INSUL
INT
JAN
JB
JST
JT
L
LAB
LAM
LAV
LB
AIR CONDITIONING
ACOUSTICAL
ACOUSTICAL CEILING TILE
ABOVE FINISH FLOOR
ABOVE FINISH GRADE
AIR HANDLING UNIT
ALUMINUM
ALTERNATE
AIR & MOISTURE BARRIER SYSTEM
AMOUNT
ACCESS PANEL
APPROXIMATE
ARCHITECTURAL
AUDIO VISUAL
BOARD
BUILDING
BLOCK
BEAM OR BENCHMARK
BOTTOM OF METAL DECK
BOTTOM OF
BOTTOM
BEARING
BASEMENT
CABINET(S)
CORNER BEAD
CENTER TO CENTER
CORNER GUARD
CAST IRON
CONTROL JOINT
CEILING
CLOSET
CLEAR
CENTIMETER
COMPOSITE METAL PANEL
CONCRETE MASONRY UNIT
CLEAN OUT
COLUMN
CONCRETE
CONSTRUCTION
CONTINUOUS
CONTRACTOR
CARPET
CERAMIC TILE
CENTER
COUNTERSINK
DOUBLE
DEGREE
DEPARTMENT
DETAIL
DIAMETER
DIAGONAL
DIMENSION
DOWN
DOOR
DOWNSPOUT
DRAWING(S)
EAST
EACH
EXTERIOR INSULATION FINISH
SYSTEM
EXPANSION JOINT
ELEVATION
ELECTRICAL
ELEVATOR
ENCLOSURE
ENGINEER
EQUAL
EQUIPMENT
EASEMENT
ELECTRIC WATER COOLER
EXHAUST
EXISTING
EXPANSION
EXTERIOR
FIRE ALARM
FAN COIL UNIT
FLOOR DRAIN
FOUNDATION
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
FINISH FLOOR
FIRE HOSE CABINET
FINISH
FLOW LINE
FLOOR
FEET
FOOTING
FUTURE
FABRIC WALL COVERING
GAUGE
GALVANIZED
GRAB BAR
GENERAL CONTRACTOR
GENERATOR
GROUND FACE BLOCK
GOVERNMENT FURNISHED &
CONTRACTOR INSTALLED
GOVERNMENT FURNISHED &
GOVERNMENT INSTALLED
GLASS FIBER REINFORCED
CONCRETE
GLASS FIBER REINFORCE
GYPSUM
GLASS
GROUND
GYPSUM WALL BOARD
HIGH
HOSE BIB
HOLLOW CORE
HANDICAP
HEAD
HARDWARE
HOLLOW METAL
HORIZONTAL
HIGH POINT
HEIGHT
HEATER
HOT WATER HEATER
HEATING VENTILATING AND
AIR CONDITIONING
INSIDE DIAMETER
INCH
INCLUDE (ED) (ING)
INFORMATION
INSULATION
INTERIOR
JANITOR
JUNCTION BOX
JOIST
JOINT
LENGTH
LABORATORY
LAMINATE
LAVATORY