AF69FD-1.PDF

PDF 2 MB Posted

Attached to
PA 206 HORSHAM HVAC SYSTEMS REPAIRS
Solicitation number
W912BU24R0001
Issued by

About this file

This document contains construction drawings and general notes for repairs to HVAC systems at the PA 206 Horsham facility. Key details include specifications for repairs to HVAC systems in buildings 5500, 5510, and 5520, with building ground floor elevations provided. Standard notes cover conforming to building codes, verifying dimensions before proceeding with work, and coordinating with other trades for rough-in locations. Product and installation requirements include partition types, mounting heights for devices, and pre-rough in coordination meetings. The related federal contract opportunity is solicitation number W912BU24R0001 from the Department of the Army Corps of Engineers Engineering District Philadelphia for HVAC system repairs at the Army Reserve Training Center Willow Grove Naval Air Station in Horsham, PA.

View the file

Other files

File Type Posted
W912BU24R0001 Amendment 0009_Cancellation.pdf PDF
W912BU24R0001 Amendment 0005.pdf PDF
10-M-800.pdf PDF
AF85D7-1.PDF PDF
AFA040-1.PDF PDF
00-M-806.pdf PDF
AF0F76-1.PDF PDF
00-MP-4.PDF PDF
AF6B67-1.PDF PDF
10-M-803.pdf PDF
AFDA0C-1.PDF PDF
00-M-201.pdf PDF
AF7DA6-1.PDF PDF
AF5B0D-1.PDF PDF
AF4200-1.PDF PDF
10-MH-1.PDF PDF
AF2EB8-1.PDF PDF
AF7BD0-1.PDF PDF
AF4273-1.PDF PDF
00-M-803.pdf PDF
10-M-801.pdf PDF
00-MP-2.PDF PDF
AF1533-1.PDF PDF
AF9D68-1.PDF PDF
AFC2EA-1.PDF PDF
AF2AEE-1.PDF PDF
AFD99B-1.PDF PDF
AF26AC-1.PDF PDF
W912BU24R0001 Amendment 0004.pdf PDF
AFFB36-1.PDF PDF
00-M-807.pdf PDF
00-M-808.pdf PDF
AF9FDC-1.PDF PDF
AF47CB-1.PDF PDF
AFRC55-2.PDF PDF
00-M-802.pdf PDF
AFFC3F-1.PDF PDF
AFC8A7-1.PDF PDF
AF8E75-1.PDF PDF
AFD903-1.PDF PDF
AF54B2-1.PDF PDF
AFD078-1.PDF PDF
00-MH-1.PDF PDF
AF0EF7-1.PDF PDF
00-MP-1.PDF PDF
00-M-805.pdf PDF
00-MH-4.PDF PDF
AF377B-1.PDF PDF
AF9D55-1.PDF PDF
AFE9FE-1.PDF PDF
Show 40 more

Latest 50 of 102 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

00-G-003

G E

N E

R A

L N

O T

E S S

Y M

B O

L K

E Y

M A

T E

R

IA

L P

A T

T E

R N

S

A B

B R

E V

IA

T

IO

N S

T Y

P

M O

U N

T

IN

G H

E

IG

H T S

AS-BUILT

S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\General\AFRC5500-G-003.dgn

9/11/2012

9:17:49 AM

rifem

F O

R U

M S

T U

D

IO

I

N N

E R

B E

L T B

U S

IN

E S

S C

E N

T E

R D

R

S T L

O U

IS

M O

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

SHEET

IDENTIFICATION

D A

T E

A P

P R

SHEET OF

fi

US Army Corps of Engineers

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

L O

U

IS

V

IL

L E D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K Y

F S

B A

Z

C L

A Y

C O C

O N

S T

R U

C T

IO

N

.1

.1

-W

Q R -0

-R -0

P -1

1 3

C O

N C

E P

T D

E S

IG

N S

U B

M

IT

T A

L .1

.0

.1

.0

R

E V

IS

E D C

H A

R R

E T

T E C

O N

C E

P T S

U B

M

IT

T A

L

IN

T

E R

IM

S

U B

M

IT

T A

L .1

.1

.2

.1

A F

R C

-G

-0 .d g n

/1

/2

F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L

A R

M Y R

E S

E R

V E T

R A

IN

IN

G C

E N

T E

R W

IL

L O

W G

R O

V E N

A V

A L A

IR

S

T A

T

IO

N W

Q R -0

-C -0

H O

R S

H A

M P

A

C

O R

R E

C T

E D F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L .0

.1

.1

.1

C

E R

T

IF

IE

D F

IN

A L S

U B

M

IT

T A

L

B R

IC

E Z

IC

K U

H R

6"

4"

6" 6"

8"

6"

1’-8"1’-8" 1’-8" 1’-8"

18"

M A

X

36" MIN.

42" MIN.

54" MIN.

12" MAX.

42" MIN.

15" MIN.

" 4

M A

X

M A

X

M A

X

15"

MIN.

8"

MIN.

17"

MIN. 3

M A

X

M A

X

36" MAX.

M

IN

9" MAX.

/2

M

IN

M A

X

M A

X

24" MAX.

17"-19"

M

IN

M A

X

M A

X

M A

X

30" MIN.

CLEAR

X

XX-A-XXX

ROOM NAME

C.L

C.L

X

X

M A

X

40"

M A

X

1’-0"

2’-0"

6" 6"

SHELF TOWEL

BAR

SOAP

DISPENSER

CLOTHES

HOOK

PAPER DISPENSER/

WASTE RECEPTACLE

(LARGE CAPACITY)

DOUBLE FOUNTAIN

(SIDE)

DOUBLE FOUNTAIN

(FRONT)

ELECTRICAL/

TELEPHONE OUTLET

ABOVE COUNTER

FIRE

EXTINGUISHER

CABINET

VISUAL

ALARM/

STROBE

DUPLEX RECEP./

COMM. OUTLET

PEEP

HOLE

COAT

HOOK

ELEVATOR

SIGNAGE

DOOR SIGNAGE/

CARD READER

LIGHT SWITCH / THERMOSTAT

SIDE REACH

(PREFERRED)

LIGHT SWITCH /

THERMOSTAT

FRONT REACH

STANDARD

SHOWER

(SIDES)

STANDARD

SHOWER

(BACK)

TOILET GRAB BAR TOILET/GRAB BAR URINAL LAVATORY /

MIRROR

(FRONT)

LAVATORY /

MIRROR

(SIDE)

TISSUE DISPENSER/

NAPKIN DISPOSAL

PAPER/TISSUE DISPENSER/

NAPKIN DISPOSAL UNIT

DOOR

SIGNAGE

CARD

READER

ACCESSIBLE

NOTE:

FRONT-REACH REQUIRES 30" X 48" CLEAR FLOOR SPACE IN

FRONT OF FIXTURE. SIDE-REACH REQUIRES 48" X 30" CLEAR

FLOOR SPACE IN FRONT OF FIXTURE.

T O

P O

F S

P O

U T

T O

P O

F S

P O

U T

T O

P O

F C

O N

T R

O L

T O

P O

F C

O N

T R

O L

B O

T T

O M O

F L

E N

S

1.

2.

3.

4.

5.

6.

7.

8.

9.

ABBREVIATIONS

TYPICAL MOUNTING HEIGHTS

LF

LH

LKR

LP

M

MA

MAS

MATL

MAX

MB

MECH

MFR

MH

MIN

MISC

MM

MO

MTD

MTL

N

NIC

NO

NOM

NTS

OA

OC

OD

OH

OHD

OPNG

OPP

OPP HD

ORD

OPT

ORIG

OTS

OZ

PARTN

PC

PERF

PJ

PL

PLAS

P LAM

PLG

PLYWD

PNL

PR

PREFAB

PRELIM

PROJ

PSF

PSI

PT

PTD

QT

QTR

R R/A

RAD

RB

RD

REF

REINF

RF

REFRG

REQD

RET

REV

RH

RM

RO

RTU

RV

S S/A

SAB

SAN

SD

SF

SHR

SHT

SIM

SM

SNR

SPEC(S)

SPKR

SQ

SS

ST

STD

STL

STOR

STRL

STRUCT

SUSP

SYM

SYS

T T&G

TELE

TEM

TEMP

TERR

THK

THRU

TO

TPH

TSS

TSTL

TU

TV

TW

TYP

UH

UNFIN

UL

UNO

VB

VENT

VERT

VEST

VIF

VP

VWC

LINEAR FEET

LEFT HAND

LOCKER

LOW POINT

METER

MARBLE

MASONRY

MATERIAL

MAXIMUM

MARKER BOARD OR MOP BASIN

MECHANICAL

MANUFACTURER

MANHOLE

MINIMUM

MISCELLANEOUS

MILLIMETER

MASONRY OPENING

MOUNTED

METAL

NORTH

NOT IN CONTRACT

NUMBER

NOMINAL

NOT TO SCALE

OVER ALL

ON CENTER

OUTSIDE DIAMETER

OVERHEAD

OVERHEAD DOOR

OPENING

OPPOSITE

OPPOSITE HAND

OVERFLOW ROOF DRAIN

OPTIONAL

ORIGINAL

OPEN TO STRUCTURE

OUNCE

PARTITION

PRECAST

PERFORATED

PANEL JOINT

PLATE

PLASTER

PLASTIC LAMINATE

PLUMBING

PLYWOOD

PANEL

PAIR

PREFABRICATED

PRELIMINARY

PROJECT

POUNDS PER SQUARE FOOT

POUNDS PER SQUARE INCH

POINT

PAINTED OR PAPER TOWEL

DISPENSER

QUARRY TILE

QUARTER

RISER

RETURN AIR

RADIUS

RESILIENT BASE

ROOF DRAIN

REFERENCE

REINFORCED (ING)

RESILIENT FLOORING

REFRIGERATOR

REQUIRED

RETAINING

REVISION

RIGHT HAND

ROOM

ROUGH OPENING

ROOF TOP UNIT

ROOF VENT

SOUTH

SUPPLY AIR

SOUND ATTENUATION BLANKET

SANITARY

SMOKE DETECTOR

SQUARE FEET

SHOWER

SHEET

SIMILAR

SQUARE METER

SANITARY NAPKIN RECEPTACLE

SPECIFICATION(S)

SPEAKER

SQUARE

STAINLESS STEEL

STREET

STANDARD

STEEL

STORAGE

STRUCTURAL

STRUCTURE

SUSPENDED

SYMMETRICAL

SYSTEM

TREAD

TONGUE & GROOVE

TELEPHONE

TEMPERED

TEMPORARY

TERRAZZO

THICK

THROUGH

TOP OF

TOILET PAPER HOLDER

TOP STRUCTURAL SLAB

TOP OF STEEL

TILT-UP

TELEVISION

TOP OF WALL

TYPICAL

UNIT HEATER

UNFINISHED

UNDERWRITER’S LABORATORY

UNLESS NOTED OTHERWISE

VAPOR BARRIER

VENTILATION

VERTICAL

VESTIBULE

VERIFY IN FIELD

VENEER PLASTER

VINYL WALL COVERING

GENERAL NOTESSYMBOL KEYMATERIAL PATTERNS

EARTH

GRAVEL /

BALLAST

STEEL

ALUMINUM

FINISH

LUMBER

SHIM

CONCRETE

CUT STONE /

PRE-CAST

CONCRETE

MASONRY

UNITS

BRICK

PLYWOOD

RIGID

INSUL.

BATT

INSUL.

FIRE

SAFING

MARBLE /

GRANITE

WOOD

BLOCKING

DETAIL KEY

ELEVATION KEY

WALL SECTION KEY

BUILDING SECTION KEY

REVISION CLOUD

NORTH ARROW

COLUMN GRID

Detail #

Sheet #

Sheet #

Sheet #

Detail #

Sheet #

Section #

Elevation#

Project North

True North

TAG KEY

ROOM TAG

WALL TAG

(PARTITION TYPE)

KEY NOTE

ACCESSORY TAG

DOOR TAG

WINDOW TAG

CEILING TAG

0’-0"

ELECTRIC

HAND

DRYER

LOUVER TAG

REFER TO SHEETS 00-G-101 AND 00-G-102 FOR CODE DATA & LIFE SAFETY

INFORMATION.

WORK SHALL CONFORM TO ALL STATE AND LOCAL APPLICABLE BUILDING CODES,

REGULATIONS AND ORDINANCES HAVING JURISDICTION.

BUILDING GROUND FINISH FLOOR ELEVATION IS 306.00’ = 100’-0" FOR BLDG 5500

BUILDING GROUND FINISH FLOOR ELEVATION IS 312.00’ = 100’-0" FOR BLDG 5510

BUILDING GROUND FINISH FLOOR ELEVATION IS 316.00’ = 100’-0" FOR BLDG 5520

SEE SHEET ##-A-501 FOR PARTITION TYPES AND TYPICAL PARTITION NOTES.

SEE SHEET 00-G-003 FOR TYPICAL MOUNTING LOCATIONS AND HEIGHTS OF DEVICES.

MECHANICAL AND ELECTRICAL SUB-CONTRACTORS TO SCHEDULE A PRE-ROUGH IN

MEETING WITH THE ARCHITECT TO COORDINATE AESTHETIC LOCATION OF OUTLET,

SWITCH, DATA, THERMOSTAT, PANEL, HORN, STROBE, AND EMERGENCY LIGHTS, ETC.

ROUGH-INS.

CONTRACTOR SHALL VERIFY ALL CONDITIONS , DIMENSIONS, AND SHALL

COORDINATE WITH TRADES IN LAYOUT OF HIS WORK. THE ALIGNMENT IN

COORDINATION OF HIS WORK AND OTHER ADJACENT WORK IS OF PRIMARY

IMPORTANCE AND SHALL TAKE PRECEDENCE OVER DIMENSIONS. CONTRACTOR

SHALL LAYOUT AND VERIFY HIS WORK TO ENSURE PROPER ALIGNMENT AND FIT.

CONTRACTOR SHALL IMMEDIATELY REPORT ANY DISCREPANCIES TO HIS

SUPERINTENDENT AND THE ARCHITECT BEFORE PROCEEDING, OR PROCEED AT

CONTRACTOR’S OWN RISK.

CONTRACTOR SHALL WORK FROM ESTABLISHED POINTS AND LINES, ESTABLISH AND

MAINTAIN MARKERS FOR LINES AND LEVELS OF WORK. DO NOT SCALE DRAWINGS,

CALCULATE DIMENSIONS AND MEASURE FOR LAYOUT OF WORK.

CONTRACTOR SHALL REPORT IMMEDIATELY ANY DISCREPANCIES TO HIS

SUPERINTENDENT AND THE ARCHITECT BEFORE PROCEEDING, OR PROCEED AT

CONTRACTOR’S OWN RISK.

THE WORD ’ALIGN’ AS IN THESE DOCUMENTS SHALL SUPERSEDE ANY DIMENSIONAL

INFORMATION SHOWN. IF A DISCREPANCY OCCURS, NOTIFY THE SUPERINTENDENT

AND ARCHITECT IMMEDIATELY.

REFER TO STRUCTURAL DRAWINGS FOR ALL JOINTS IN FLOOR SLAB(S).

NON-

ACCESSIBLE

CL

PLAN

NORTH

TACKBOARD CHAIR RAILMARKER BOARD W/ 2"

MAP RAIL ON TOP AND

2" TRAY ON BOTTOM

ENCLOSED

TACKBOARD

MAP RAIL

MAX. FRONT

REACH TO TOP OF

CONTROL

MAX. SIDE REACH

TO TOP OF

CONTROL

TOWEL

HOOK

INTERIOR

SIGNAGE TYPE

DD1

INTERIOR

SIGNAGE TYPE

CC2

C L

EXTERIOR

SIGNAGE TYPE

B5

INTERIOR / EXTERIOR

SIGNAGE TYPE

BB2,BB7

A/C

ACOUS

ACT

AFF

AFG

AHU

AL

ALT

A.M.B.S.

AMT

AP

APPROX

ARCH

A/V

BD

BLDG

BLK

BM

BMD

BO

BOT

BRG

BSMT

CAB(S)

CB

C/C

CG

CI

CJ

CLG

CLO

CLR

CM

CMP

CMU

CO

COL

CONC

CONSTR

CONT

CONTR

CPT

CT

CTR

CTSK

DBL

DEG

DEPT

DTL

DIA

DIAG

DIM

DN

DR

DS

DWG(S)

E

EA

EIFS

EJ

EL

ELEC

ELEV

ENCL

ENGR

EQ

EQUIP

ESMT

EWC

EXH

EXIST

EXP

EXT

FA

FCU

FD

FDN

FE

FEC

FF

FHC

FIN

FL

FLR

FT

FTG

FUT

FWC

GA

GALV

GB

GC

GEN

GFB

GFCI

GFGI

GFRC

GFRG

GL

GND

GWB

H

HB

HC

HDCP

HD

HDW

HM

HORIZ

HP

HGT

HTR

HWH

HVAC

ID

IN

INCL

INFO

INSUL

INT

JAN

JB

JST

JT

L

LAB

LAM

LAV

LB

AIR CONDITIONING

ACOUSTICAL

ACOUSTICAL CEILING TILE

ABOVE FINISH FLOOR

ABOVE FINISH GRADE

AIR HANDLING UNIT

ALUMINUM

ALTERNATE

AIR & MOISTURE BARRIER SYSTEM

AMOUNT

ACCESS PANEL

APPROXIMATE

ARCHITECTURAL

AUDIO VISUAL

BOARD

BUILDING

BLOCK

BEAM OR BENCHMARK

BOTTOM OF METAL DECK

BOTTOM OF

BOTTOM

BEARING

BASEMENT

CABINET(S)

CORNER BEAD

CENTER TO CENTER

CORNER GUARD

CAST IRON

CONTROL JOINT

CEILING

CLOSET

CLEAR

CENTIMETER

COMPOSITE METAL PANEL

CONCRETE MASONRY UNIT

CLEAN OUT

COLUMN

CONCRETE

CONSTRUCTION

CONTINUOUS

CONTRACTOR

CARPET

CERAMIC TILE

CENTER

COUNTERSINK

DOUBLE

DEGREE

DEPARTMENT

DETAIL

DIAMETER

DIAGONAL

DIMENSION

DOWN

DOOR

DOWNSPOUT

DRAWING(S)

EAST

EACH

EXTERIOR INSULATION FINISH

SYSTEM

EXPANSION JOINT

ELEVATION

ELECTRICAL

ELEVATOR

ENCLOSURE

ENGINEER

EQUAL

EQUIPMENT

EASEMENT

ELECTRIC WATER COOLER

EXHAUST

EXISTING

EXPANSION

EXTERIOR

FIRE ALARM

FAN COIL UNIT

FLOOR DRAIN

FOUNDATION

FIRE EXTINGUISHER

FIRE EXTINGUISHER CABINET

FINISH FLOOR

FIRE HOSE CABINET

FINISH

FLOW LINE

FLOOR

FEET

FOOTING

FUTURE

FABRIC WALL COVERING

GAUGE

GALVANIZED

GRAB BAR

GENERAL CONTRACTOR

GENERATOR

GROUND FACE BLOCK

GOVERNMENT FURNISHED &

CONTRACTOR INSTALLED

GOVERNMENT FURNISHED &

GOVERNMENT INSTALLED

GLASS FIBER REINFORCED

CONCRETE

GLASS FIBER REINFORCE

GYPSUM

GLASS

GROUND

GYPSUM WALL BOARD

HIGH

HOSE BIB

HOLLOW CORE

HANDICAP

HEAD

HARDWARE

HOLLOW METAL

HORIZONTAL

HIGH POINT

HEIGHT

HEATER

HOT WATER HEATER

HEATING VENTILATING AND

AIR CONDITIONING

INSIDE DIAMETER

INCH

INCLUDE (ED) (ING)

INFORMATION

INSULATION

INTERIOR

JANITOR

JUNCTION BOX

JOIST

JOINT

LENGTH

LABORATORY

LAMINATE

LAVATORY

POUND