This document contains a floor plan and notes for the second floor of an Army Reserve Training Center located at Willow Grove Naval Air Station in Horsham, Pennsylvania. The floor plan depicts the layout of offices, conference rooms, and other facilities, and notes provide information on wall construction types, finishes, and other architectural details.
The related federal contract opportunity is a special notice for HVAC system repairs at the PA 206 Horsham facility. The solicitation is issued by the Department of the Army Corps of Engineers Engineering District Philadelphia. The notice seeks contractors to perform repairs to the HVAC systems at the Horsham location, as depicted in the floor plan. Relevant details include the agency issuing the solicitation, the type of requirement, and the location of work.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W912BU24R0001 Amendment 0009_Cancellation.pdf | ||
| W912BU24R0001 Amendment 0005.pdf | ||
| 10-M-800.pdf | ||
| AF85D7-1.PDF | ||
| AFA040-1.PDF | ||
| 00-M-806.pdf | ||
| AF0F76-1.PDF | ||
| 00-MP-4.PDF | ||
| AF6B67-1.PDF | ||
| 10-M-803.pdf | ||
| AFDA0C-1.PDF | ||
| 00-M-201.pdf | ||
| AF7DA6-1.PDF | ||
| AF5B0D-1.PDF | ||
| AF4200-1.PDF | ||
| 10-MH-1.PDF | ||
| AF2EB8-1.PDF | ||
| AF7BD0-1.PDF | ||
| AF4273-1.PDF | ||
| 00-M-803.pdf | ||
| 10-M-801.pdf | ||
| 00-MP-2.PDF | ||
| AF1533-1.PDF | ||
| AF9D68-1.PDF | ||
| AFC2EA-1.PDF | ||
| AF2AEE-1.PDF | ||
| AFD99B-1.PDF | ||
| AF26AC-1.PDF | ||
| W912BU24R0001 Amendment 0004.pdf | ||
| AFFB36-1.PDF | ||
| 00-M-807.pdf | ||
| 00-M-808.pdf | ||
| AF9FDC-1.PDF | ||
| AF47CB-1.PDF | ||
| AFRC55-2.PDF | ||
| 00-M-802.pdf | ||
| AFFC3F-1.PDF | ||
| AFC8A7-1.PDF | ||
| AF8E75-1.PDF | ||
| AFD903-1.PDF | ||
| AF54B2-1.PDF | ||
| AFD078-1.PDF | ||
| 00-MH-1.PDF | ||
| AF0EF7-1.PDF | ||
| 00-MP-1.PDF | ||
| 00-M-805.pdf | ||
| 00-MH-4.PDF | ||
| AF377B-1.PDF | ||
| AF9D55-1.PDF | ||
| AFE9FE-1.PDF |
Show 40 more
Latest 50 of 102 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
00-A-1061/8" = 1’ 0" A4
SECOND FLOOR PLAN - EAST
T R
A
IN
IN
G C
E N
T E
R S
E C
O N
D F
L O
O R P
L A
N E
A S
T
AS-BUILT
S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5500-A-106.dgn
9/11/2012
9:20:11 AM
rifem
F O
R U
M S
T U
D
IO
I
N N
E R
B E
L T B
U S
IN
E S
S C
E N
T E
R D
R
S T L
O U
IS
M O
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
fi
US Army Corps of Engineers
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S I
D
L O
U
IS
V
IL
L E D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K Y
GENERAL NOTES
KEY PLAN
KEY NOTES
GRAPHIC SCALE
8’0 4’ 16’
SCALE:1/8"=1’
F S
B A
Z
C L
A Y
C O C
O N
S T
R U
C T
IO
N
.1
.1
-W
Q R -0
-R -0
P -1
1 3
C O
N C
E P
T D
E S
IG
N S
U B
M
IT
T A
L .1
.0
.1
.0
R
E V
IS
E D C
H A
R R
E T
T E C
O N
C E
P T S
U B
M
IT
T A
L
IN
T
E R
IM
S
U B
M
IT
T A
L .1
.1
.2
.1
A F
R C
-A -1
.d g n
/1
/2
F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L
A R
M Y R
E S
E R
V E T
R A
IN
IN
G C
E N
T E
R W
IL
L O
W G
R O
V E N
A V
A L A
IR
S
T A
T
IO
N W
Q R -0
-C -0
H O
R S
H A
M P
A
C
O R
R E
C T
E D F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L .0
.1
.1
.1
C
E R
T
IF
IE
D F
IN
A L S
U B
M
IT
T A
L
B R
IC
E Z
IC
K U
H R
15’-11"10’-5"10’-5"10’-5"10’-5"
/8
11"12’-9"12’-9 1/8 "
6"
11’-11"10’-5"10’-5"
/4
N
O .2
A P
A I
H
G
226A
226B
226C
220N
220M
202A
D
I
H
C
B
A
F
E
A
J
K
L
O
P
U
T
A
R
Q
V
A
A
D
A
B
A
A
B
C
D
E
/8
333333
3 3 3
3 3
3 3
3 3 3 3 3
3 3
3 3
3 3 3
M A
T C
H L
IN
E
A
-A -1
W
3’-3 7/8 " 12’-4"
A L
IG
N
A L
IG
N
/8
/2
/2
/8
/2
/2
2’-0 1/4 "
00-A-802
C5
00-A-511
C5
SIM
A4
A4
TYP
B4
A L
IG
N
1’-7 7/8 "
2’-6 1/8 "
2’-5 7/8 " 2’-6"
B2
C2
1’-0"
8’-8 1/8 "7"
/2
2’-1"2’-6"
1’-4" 9"
3’-0" 4’-0"
5’-4" 4’-0" 5’-4" 4’-0" 5’-4" 3’-8" 4’-0" 4’-0" 4’-0"
1’-6" 2’-6"
4’-0" 4’-0" 4’-0" 3’-8" 5’-4" 4’-0" 5’-4" 4’-0" 4’-4" 6’-4" 4’-0" 5’-4" 4’-0" 5’-4" 9’-4"
2’-4"
4’-0" 4’-0" 4’-0" 4’-0" 4’-0" 18’-4"
1’-8"
4’-0" 5’-6"
1’-10"
4’-0" 7’-4" 4’-0" 7’-4" 4’-0" 7’-4" 4’-0"
1’-4"
10’-0" 7’-4" 4’-0" 7’-4" 4’-0"
1’-8"
5’-8" 4’-0" 7’-4" 4’-0" 7’-4" 4’-0" 8’-4"
1’-8"
1’-8"
14’-8"
5’-11" 4’-6" 9’-0" 3’-11"
13’-0" 17’-4"
2’-4 1/8 "
14’-11 7/8 " 16’-4" 8’-5 1/8 "
11"
6’-3 7/8 " 9’-5 1/8 " 9’-5" 8’-3 3/4 "
2’-0 1/4 "
5’-0" 9’-10" 9’-5" 5’-6" 9’-9"
6’-3 7/8 " 9’-5 1/8 " 9’-5" 10’-4" 5’-0" 9’-10" 9’-5" 5’-6" 9’-9"
/8
8 8
S
2F
TW
T
1B
SW
T
1B
SW
T
1B
SW
S
2A
SW
S
2E
SW
T
1B
SW
@DOOR
FRAME
@DOOR
FRAME
@DOOR
FRAME
@DOOR
FRAME
@DOOR
FRAME
@DOOR
FRAME
@DOOR
FRAME
@DOOR
FRAME
T
1B
SW
SW T
1B
ALIGN
ALIGN
A L
IG
N
01010101020101010101010101
01 01 01 01 01 01 01 01 01 01 01
TYP.
PLAN
NORTH
T
1A
T
1A
T
1A
T
1A
T
1A
T
1A
1B PARTIAL
HEIGHT
CONTROL JOINT, SEE DETAIL ON SHEET 00-A-501 FOR INFORMATION
CLASS 5 SAFE (GFGI)
PROVIDE 4x3 TACKBOARD WITH 1/2" ALUMINUM TRIM, SEE MOUNTING HEIGHTS
ELEVATION ON 00-G-003 FOR MORE INFORMATION
OUTLINE OF ROOF BELOW
SEMI-RECESSED FIRE EXTINGUISHER CABINET
4" CONC. EQUIPMENT PAD
SLAB PENETRATION - SEE STRUCTURAL FOR DETAILS
PLUMBING VENT
RADON PIPING
6 6.4 7 7.8 8 9 10
A
B
C
D
E
210A
UNIT COMMON
202A
ELEC
213F
157 F/T OFFICE
213G
213H
213I
157 PS OFFICE
213O
213P
DRT 733 F/T OFC
216A
TM26 150 PS OFC
217A
TM32 154 PS OFC
218A
TM32 154 PS OFC
220A
338 UE OFFICE
220B
220C
220D
220E
338 F/T OFFICE
220F
220G
220H
220I
338 F/T OFC
220J
220K
220L
220M
F/T OFFICE
220N
F/T OFFICE
220O
338 PS OFFICE
220P
338 PS OFC
220Q
220R
220S
220T
338 PS OFFICE 220U
338 PS OFC
220V
220W
221A
TM8 153 PS OFC
222A
TM8 153 OFFICE
223A
TM1 153 UE OFFICE223B
TM1 153 UE OFFICE
223C
TM1 153 UE OFFICE
223D
TM8
153 PS OFC
224A
HQ 223 UE OFFICE
224B
HQ 223 F/T OFFICE
224C
224D
224E
226A
427 F/T OFC
226B
427 PS OFC
226C
427 F/T OFC
B
STAIR
201G
CORR
201F
201A
201H
GENERAL SUPPORT
1. ALL PARTITIONS ON THE FIRST FLOOR OF THE TRAINING BUILDING
TO BE TYPE 2A / S, SW. U.N.O.
2. ALL PARTITIONS ON THE SECOND FLOOR OF THE TRAINING
BUILDING TO BE TYPE 2A / T @ 10’-0", SW. U.N.O.
3. ALL PARTITIONS IN THE OMS / AMSA BUILDING TO BE TYPE 2A / S,
SW. U.N.O.
4. INSTALL A COAT HOOK ON THE WALL BEHIND THE DOOR IN ITS
OPENED POSITION IN THE SUPPLY OFFICE, FACILITY MANAGER,
FAMILY SUPPORT, REC / RET OFFICE, AND ALL PRIVATE OFFICES,
SEE THE TYPICAL MOUNTING HEIGHTS ELEVATION ON 00-G-003.
5. INSTALL POLYVINYL CORNER GUARDS 6" A.F.F. TO 6" BELOW THE
CEILING WHERE INDICATED ON THE PLAN FOR ALL PUBLIC
SPACES.
6. INSTALL STEEL CORNER GUARDS 6" A.F.F. TO 6" BELOW THE
CEILING WHERE INDICATED ON THE PLAN IN THE UNIT STORAGE
SPACE ONLY.
7. PROVIDE BLINDS AT ALL EXTERIOR WINDOWS.
8. SEE THE INTERIOR DRAWINGS FOR ALL FURNITURE AND
EQUIPMENT LAYOUTS.
9. DIMENSIONS ARE TO COLUMN LINES, FACE OF MASONRY, OR FACE
OF GYP.
10. REFER TO 00-G-003 FOR MATERIAL LEGEND OF HATCHED WALL TYPES.
File details come from the government source that posted it. Updated .