Pages from Pages from 20241108_USDA_DFRC_RTA_Dwgs_V1_4-2.pdf

PDF 3 MB Posted

Attached to
CANCELED - USDA Dairy Forage Research Center (DFRC)
Solicitation number
W9128F25R0014
Issued by

About this file

These pages contain detailed engineering drawings and specifications for a fire pump house and related fire protection systems at the USDA Dairy Forage Research Center in Prairie du Sac, WI. The drawings include electrical, telecommunications, security, and fire protection details for a facility that houses a diesel engine fire pump, 330,000-gallon fire water storage tank, and associated equipment.

The drawings show specific technical requirements including fire protection system components, security camera placements, telecommunications infrastructure, and life safety features. Key details include a diesel fire pump with 100-gallon fuel tank, jockey pump system, fire alarm control panels, access control systems, and fiber optic network connections. The facility incorporates multiple safety monitoring systems including fire pump controllers that monitor conditions like pump running status, failure to start, charger/battery status, oil pressure, temperature, and fuel levels. The drawings provide comprehensive construction specifications for contractors, including detailed elevations, floor plans, riser diagrams, and equipment layouts with extensive technical notes regarding system operations, pressure settings, and control parameters.

View the file

Other files

File Type Posted
W9128F25R0014 Amendment 16 - 09.09.2025.pdf PDF
W9128F25R0014 Amendment 15 - 07.22.2025.pdf PDF
Am_0015_Dwgs_ARS01.pdf PDF
W9128F25R0014 Conformed thru Amd 15 - 07.22.2025.pdf PDF
JA_CECT-NWO-25-15_DFRC_Calan Feeding System_Redacted.pdf PDF
W9128F25R0014 Conformed thru Amd 14 - 07.11.2025.pdf PDF
W9128F25R0014 Amendment 14 - 07.11.2025.pdf PDF
W9128F25R0014 Amendment 13 - 07.10.2025.pdf PDF
Am_0013_Specs_ARS01.pdf PDF
W9128F25R0014 Conformed thru Amd 13 - 07.10.2025.pdf PDF
Am_0013_Dwgs_ARS01.pdf PDF
Am_0012_Specs_ARS01.pdf PDF
Am_0012_Dwgs_ARS01.pdf PDF
W9128F25R0014 Amendment 12 - 06.16.2025.pdf PDF
W9128F25R0014 Conformed thru Amd 12 - 06.16.2025.pdf PDF
W9128F25R0014 Amendment 11 - 06.06.2025.pdf PDF
W9128F25R0014 Conformed thru Amd 11 - 06.06.2025.pdf PDF
Am_0011_Dwgs.pdf PDF
Am_0010_Specs.pdf PDF
W9128F25R0014 Conformed thru Amd 10 - 05.30.2025.pdf PDF
Am_0010_Dwgs.pdf PDF
W9128F25R0014 Amendment 10 - 05.30.2025.pdf PDF
W9128F25R0014 Conformed thru Amd 09 - 05.23.2025.pdf PDF
Am_0009_Dwgs_ARS01.pdf PDF
W9128F25R0014 Conformed thru Amd 09 - 05.23.2025.pdf PDF
W9128F25R0014 Amendment 09 - 05.23.2025.pdf PDF
Am_0009_Specs_ARS01.pdf PDF
Am_0008_Specs_ARS01.pdf PDF
Am_0008_Dwgs_ARS01.pdf PDF
W9128F25R0014 Amendment 08 - 05.16.2025.pdf PDF
Site Visit_24 Apr 2025_Sign in Sheet.jpg JPG image
W9128F25R0014 Conformed thru Amd 08 - 05.16.2025.pdf PDF
W9128F25R0014_Conformed Amd 07 - 04.01.2025.pdf PDF
Amendment 07 - Ad_0007_Drawings_04.01.2025.pdf PDF
Amendment 07 - Ad_0005_Drawings_04.01.2025.pdf PDF
Amendment 07 - Ad_0006_Drawings_04.01.2025.pdf PDF
W9128F25R0014 Amendment 07 - 04.01.2025.pdf PDF
Amendment 07 - Ad_0011_Drawings_04.01.2025.pdf PDF
Amendment 07 - Ad_0008_Drawings_04.01.2025.pdf PDF
Amendment 07_Specifications_04.01.2025.pdf PDF
Amendment 07 - Ad_0003_Drawings_04.01.2025.pdf PDF
W9128F25R0014_CONFORMED THROUGH Amd 07 - 04.01.2025.pdf PDF
Amendment 07 - Ad_0010_Drawings_04.01.2025.pdf PDF
Amendment 07 - Ad_0009_Drawings_04.01.2025.pdf PDF
Amendment 07 - Ad_0002_Drawings_04.01.2025.pdf PDF
Amendment 07 - Ad_0004_Drawings_04.01.2025.pdf PDF
W9128F25R0014-0006_Dairy Forage_02.14.2025.pdf PDF
W9128F25R0014 - Amendment 0005 - 20250114.pdf PDF
Site Visit Sign in Sheet.pdf PDF
W9128F25R0014 - Amendment 0004 - 20241223.pdf PDF
Show 40 more

Latest 50 of 94 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FINISHED FLOOR

PROVIDE WEATHER

PROOF SEAL AT

PENETRATION

BUSHING WITH 1/2" SMOOTH

BORE CORROSION RESISTANT

OUTLET EQUIVALENT TO

SPRINKLER ORIFICE

SPLASH BLOCK

1" 45 DEG.

ELBOW

1" TEST VALVE

OUTSIDE WALL

M A

X

M A

X

DRY SYSTEM

AUXILIARY

DRAIN

1" TEST VALVE

FROM MOST REMOTE

BRANCHLINE ON SYSTEM

1. BALL DRIP, PIPE TO FLOOR DRAIN

ITEM DESCRIPTION

2. AHJ COMPLIANT FIRE DEPARTMENT CONNECTION

3. CHECK VALVE

4. ELECTRIC HORN AND STROBE

5. PRESSURE TYPE FLOW SWITCH, LOW PRESSURE

SWITCH, ETC MONITORED BY FIRE ALARM

CONTROL PANEL

6. DRY PIPE VALVE

7. WATER PRESSURE GAUGE

9. MAIN DRAIN VALVE

10. MAIN DRAIN

11. AHJ APPROVED INDICATING CONTROL VALVE

W/TAMPER SWITCH CONNECTED FIRE ALARM SYSTEM

12. RISER FROM MAIN WATER SUPPLY, SEE WATER MAIN BUILDING

ENTRANCE DETAIL FOR INSTALLATION REQUIREMENTS

13. THRUST ROD AND SLEEVE FLOOR PENETRATION PER NFPA 13

MIN. 4'-0" THERMAL

BREAK

SPLASH BLOCK

FINISHED FLOOR

8. RISER TO SPRINKLER SYSTEM

14. SEE WATER MAIN BUILDING ENTRANCE DETAIL ON THIS SHEET

FOR CONTINUATION.

15. NITROGEN GENERATOR CABINET WITH AIR COMPRESSOR

1. BALL DRIP, PIPE TO FLOOR DRAIN

ITEM DESCRIPTION

2. AHJ COMPLIANT FIRE DEPARTMENT CONNECTION

3. CHECK VALVE

4. ELECTRIC HORN AND STROBE

5. WATER FLOW INDICATOR CONNECTED TO FACP

6. RISER CHECK VALVE WITH INTEGRAL DRAIN

7. WATER PRESSURE GAUGE

9. MAIN DRAIN VALVE

10. MAIN DRAIN

11. AHJ APPROVED INDICATING CONTROL VALVE

W/TAMPER SWITCH CONNECTED FIRE ALARM SYSTEM

12. RISER FROM MAIN WATER SUPPLY, SEE WATER MAIN BUILDING

ENTRANCE DETAIL FOR INSTALLATION REQUIREMENTS

13. THRUST ROD AND SLEEVE FLOOR PENETRATION PER NFPA 13

14. SEE WATER MAIN BUILDING ENTRANCE DETAIL ON THIS SHEET

FOR CONTINUATION.

M

IN

T H

E R

M A

L B

R E

A K

SPLASH BLOCK

FINISHED FLOOR

8. RISER TO SPRINKLER SYSTEM

WALL

FIRE SERVICE MAIN

DUCTILE IRON FLANGE

AND SPIGOT PIECE

SEAL FLOOR PENETRATION

WATERTIGHT

FINISHED FLOOR

3/4" TIE RODS

(TYP. OPP. SIDE)

DUCTILE IRON

MJ PIPE

SUPPLY UNDER FOOTING.

INSTALL PER NFPA 13.

WHEN THIS PIECE EXCEEDS

HALF A LENGTH, STRAPS MAY

BE RUN ONLY TO FIRST

OUTSIDE JOINT

3/4" TIE RODS

(TYP. OPP. SIDE)

FOOTING OR

BOTTOM GRADE

BEAM

N F

P A

M

IN

P

E R

THRUST BLOCK

PER NFPA 24

1 CHECK VALVE

2 BALL DRIP DRAIN TO BUILDING EXTERIOR

3 FIRE DEPARTMENT CONNECTION ESCUTCHEON PLATE

4 FIRE DEPARTMENT CONNECTION WITH AUTHORITY

HAVING JURISDICTION APPROVED THREADS

KEYNOTES

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

N E

W D

A

IR

Y F

O R

A G

E R

E S

E A

R C

H C

E N

T E

R

A u to d e s k D o c s

/1 U

S D

A D

F R

C /4

-F

-A L L -C e n tr a l.

rv t

/3

/2

:1

:1

P M

FP-501

F

IR

E P

R O

T E

C T

IO

N

D E

T A

IL

S

P R

A

IR

IE

D

U S

A C

W

I O

M A

H A

D

IS

T R

IC

T

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

B D

U H

A C

E K

T F

R E

E M

A N

G K

L E

IM

A

N

J W

A R

B O

Y S

/0

/2

W F

C

W F

C

NOT TO SCALEB8

DRY PIPE INSPECTOR'S TEST

CONNECTION DETAIL

NOT TO SCALEH1

TYPICAL DRY FIRE PROTECION RISER

DETAIL

NOT TO SCALEH10

TYPICAL WET FIRE PROTECTION RISER

DETAIL

NOT TO SCALEB1

WATER MAIN BUILDING ENTRANCE DETAIL

NOT TO SCALEB15

FIRE DEPARTMENT CONNECTION

R T

A

/0

/2

C1

C1

S

S S

D D S

D

D

CO

S S

D

D D

D

S

D

DD

D

D

CO

CO

CO

COCO

D

D D

CO

CO

FH

FH

CO

CO

CO

CO

D

D

D

DDD

CBCB

CB

CB

CB

D

D

D

FDFD

FD

FD FD

FD

FDFD

FD

FD

FD

E1

E2

C1-2

C2

C3

B6

B5B4

B3B2B1

A

B8

C1-1

B10

B11

B7

B9

ISOLATION VALVE &

PRESSURE REGULATING

VALVE (TYPICAL FOR EACH

BUILDING PROVIDED WITH

NATURAL GAS)

G

G G

G

G

G G

G

G G

G

G

GG

G

G G G

G

G

G

G

G G

G

G

G

G

G

G

G

G

GENERATOR

GENERATOR

PROPOSED ALLIANT

ENERGY NATURAL

GAS SERVICE METER

SET PAD.

SEE DETAIL A13

PROPOSED NATURAL

GAS SERVICE &

METER SET BY

ALLIANT ENERGY

PROPOSED NATURAL

GAS PIPING BY

CONTRACTOR

FIRE

PUMP

SHED

1-1/4"

1-1/2"

1-1/4" 2"

3"1-1/4"

3"

1-1/4"1-1/4"

3"

1" 4"

4"

4" 4"

4"

6"

1-1/4"

1-1/4"

1"

3"

3"

5"

1-1/2"

1"

1"

B12.2

B12.1 B13

B15

B14

14' - 0"

3' - 0"3' - 0"

NATURAL GAS METER SET

BY ALLIANCE ENERGY

ACCESS GATE

(TYPICAL FOR 2)

FENCE

ENCLOSURE

CONCRETE PAD

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

N E

W D

A

IR

Y F

O R

A G

E R

E S

E A

R C

H C

E N

T E

R

A u to d e s k D o c s

/1 U

S D

A D

F R

C /4

-P

-A R

E A

A -C e n tr a l.

rv t

/3

/2

:0

:0

P M

PS-101

P L U

M B

IN

G

S

IT

E P

L A

N

N A

T U

R A

L G

A S

P R

A

IR

IE

D

U S

A C

W

I O

M A

H A

D

IS

T R

IC

T

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

K E

Y

K E

Y

O M

/0

/2

W F

C

W F

C

1" = 100'-0"D1

PLUMBING SITE PLAN - NATURAL GAS

NORTH

KEY PLAN

R T

A

/0

/2

NOTES:

1. REFER TO SPECIFICATION SECTION 33 11 23 FOR SITE NATURAL GAS SYSTEM PIPING.

2. PIPE SIZING SHOWN ASSUMES 5 PSI AT OUTLET OF METER SET AND 1.5 PSI AT END

OF LONGEST RUN (3.5 PSI PRESSURE DROP). GAS SPECIFIC GRAVITY OF 0.60.

3. EACH BUILDING WILL HAVE A PRESSURE REGULATING VALVE TO REDUCE THE

PRESSURE TO BETWEEN 7 TO 14 INCHES WATER COLUMN.

4. BID OPTION 4

1/4" = 1'-0"A13

NATURAL GAS METER SET PAD DETAIL

EXISTING FACILITY DETAILS

SYMBOL FACILITY DESCRIPTION

E1 SMALL EQUIPMENT BUILDING

E2 CONSERVATION CLUB BUILDING

PROPOSED FACILITY DETAILS

SYMBOL FACILITY DESCRIPTION

A VISITOR'S CENTER, ADMIN & LAB

B1 ANIMAL EMISSION CHAMBERS

B2

CONVENTIONAL FREESTALLB3

MILKING PARLORB4

SPECIAL NEEDS & MATERNITYB5

ROBOTIC FREESTALLB6

ADVANCED ANIMAL NUTRITION

CALF BARNB7

AGRONOMY BUILDINGB8

FEED MIXINGB9

FEED STORAGEB10

PROPOSED FACILITY DETAILS

SYMBOL FACILITY DESCRIPTION

B11 SHOP, PESTICIDE & MACHINE STORAGE

B12.1 CONNECTOR

B12.2

MILK HOUSEB13

FUEL STORAGEB14

COMODITY STORAGEB15

LIQ WASTE STORAGE FACILITY - CELL 1C1-1

CONNECTOR AND SORTING

C1-2

SOLID STACK BUILDINGC2

SOLIDS/SAND SEPARATION FACILITYC3

LEACHATE RUNOFF COLLECTIONC4

LIQ WASTE STORAGE FACILITY - CELL 2

KYRJANAINEN

Image

E1

E2

C1

C1

C2

C3

B10

B14

CO

S

CO

CO

COCO

CO

CO

CO

CO

CO

CO

BS30FBS30ABS30ABS30A

B S A

B S A

B S A

BS30A

B S F

B S A

B S A

B S A

B S A

B S F

B S A

B S A

B S A

B S A

B S A

B S A

B S A

B S A

B S A

B S A

B S A

B S A

BS30ABS30ABS30F*BS30A*BS30A*

B S A

T B C

T B C

PROPOSED LOCATION OF

EMERGENCY GENERATOR

EXISTING 12.47KV

OVERHEAD UTILITY

SERVICE

UE UE UE

UE

UEUEUEUEUEUE

UE

UE

UE

UE

UE

UE

UE

UE

AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE

AE

AE

AE

AE

AE

UE

UE

UE

UE

UE

UE

UE

EXISTING 12.47KV

OVERHEAD UTILITY

SERVICE

EXISTING 12.47KV

OVERHEAD UTILITY

SERVICE

NEW OVERHEAD

SERVICE CONDUCTORSMV-T1-S

2500kVA 12.47kV TO

480/277V PAD MOUNTED

STEP-DOWN

TRANSFORMER

BUILDING B1, B2, &

B3 WILL BE FED

FROM BUILDING A

PROVIDE ONE (1) 45kVA 480V TO 208/120V TRANSFORMER AND ONE (1) 30kVA 480V

TO 208/120V TRANSFORMER

PROVIDE ONE (1) 45kVA

480V TO 208/120V

TRANSFORMER AND ONE

(1) 15kVA 480V TO 208/120V

TRANSFORMER

93.75kVA/75kW 480/277V NATURAL GAS

GENERATOR FOR THE FIRE PUMP

HOUSE, BUILDING B5, B7, B9, & B11

MV-T2-S

400kVA 12.47kV TO

480/277V PAD MOUNTED

STEP-DOWN

TRANSFORMER

UE UE UE

UE

PROVIDE ONE (1) 30kVA 480V TO 208/120V TRANSFORMER AND ONE (1) 30kVA 480V TO

208/120V TRANSFORMER

S3

UE UE UE UE UE UE UE UE

UE

UE

UE

UE UE UEUE UE UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

POWER FOR

AREA C1

UE UE UE UE

BUILDING B6 & B13

WILL BE FED

FROM BUILDING

A1

BUILDING B4 WILL

BE FED FROM

BUILDING A1

BUILDING B8 WILL

BE FED FROM

BUILDING A1

(PROVIDE TWO (2)

45kVA 480V TO

208/120V

TRANSFORMERS)

UE

UE UE UE

UE

UE

UE UE UE

UE

PROVIDE ONE (1) 300kVA 480V TO 208/120V TRANSFORMER AND ONE (1) 45kVA 480V

TO 208/120V TRANSFORMER

PROVIDE ONE (1) 75kVA 480V TO 208/120V TRANSFORMER AND ONE (1) 45kVA 480V

TO 208/120V TRANSFORMER

PROVIDE TWO (2) 45kVA 480V TO 208/120V

TRANSFORMERS

PROVIDE TWO (2) 112.kVA 480V TO

208/120V TRANSFORMERS

ONE (1) SET OF 4-#2 &

#2/0(G) IN A 2-WAY, 4" PVC,

SCHEDULE 40. CONCRETE

ENCASED DUCTBANK

TWO (2) SETS OF 4#350 &

#2/0(G) IN A 4-WAY, 4" PVC,

SCHEDULE 40. CONCRETE

ENCASED DUCTBANK

TWO (2) SETS OF 3-#1/0 &

#3(G) IN A 4-WAY, 4" PVC,

SCHEDULE 40. CONCRETE

ENCASED DUCTBANK

TWO (2) SETS OF 3-#2 &

#4(G) IN A 4-WAY, 4" PVC,

SCHEDULE 40. CONCRETE

ENCASED DUCTBANK

TWO (2) SETS OF 3-#1/0 &

#6(G) IN A 4-WAY, 4" PVC,

SCHEDULE 40. CONCRETE

ENCASED DUCTBANK

MH

MH

MHMH

MH

MH

MH

MH

MH

UE UE UE UE UE UE UE MH

UE

UE

PROVIDE ONE (1) 480V 100A WEATHERPROOF

DISCONNECT SWITCHES FOR THE SUBMERSIBLE

PUMP WITH A CONTROLLER. REFER TO THE CIVIL

PLANS AND ES-103 FOR MORE INFORMATION.

UEUEUEUEUE

UE

UE

UE

MH

PROVIDE ONE (1) SET OF 4#4/0 & 1#4 (G) IN

A 2-WAY 4" PVC, SCHEDULE 40. CONCRETE

ENCASED DUCTBANK FOR THE

EMERGENCY AND NORMAL FEEDERS.

UE

UE

UE

UE

UE

UE

UE

UE

UE

MHUE UE UE UE UE UE UE UE UE UE

UE

UE

MH

MHMH

MH

MH

UE

UE

UE

UE UE UE

UE

UE

UE

UE UE

UE

UE UE UE UE UE UE UE UE UE

UE

UE UE UE UE

UE

UE

UE

UE

UEUEUE

UE

UE UE

UE

UE

TYP. THREE (3) SETS OF 3-500MCM &

#2/0(G) IN A 4-WAY, 4" PVC,

SCHEDULE 40. CONCRETE

ENCASED DUCTBANK

MH

UEUEUE

UE

UE

UE

UE

UE

UTILITIES

RESPONSIBILITY

CONTRACTOR'S

RESPONSIBILITY

POWER FOR

AREA C3

UTILITIES

RESPONSIBILITY

CONTRACTOR'S

RESPONSIBILITY

UE UE UE UE UE

POWER FOR

AREA C2

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

N E

W D

A

IR

Y F

O R

A G

E R

E S

E A

R C

H C

E N

T E

R

A u to d e s k D o c s /1

U

S D

A D

F R

C

/4

-E

-A R

E A

A -C e n tr a l.

rv t

/6

/2

:0

:3

P

M

ES-101

E L E

C T

R

IC

A L S

IT

E

P L A

N

P R

A

IR

IE

D

U S

A C

W

I O

M A

H A

D

IS

T R

IC

T

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

R A

Y M

O N

D G

A O

R A

Y M

O N

D G

A O

B E

N J A

M

IN

O M

E D

IC

H

/0

/2

W F

C

W F

C

NORTH

KEY PLAN

A B1

B8

B2

B3

B4 B5 B13

B6 B9

B15

B7

B11

B10

C2

C4

C3 C1

B14

A B1

B8

B2

B3

B4 B5 B13

B6 B9

B15

B7

B11

B10

C2

C4

C3 C1

B14B12.1

B12.2

R T

A

/0

/2

1" = 80'-0"1

ELECTRICAL SITE PLAN

GENERAL NOTES

1. COORDINATE ALL REQUIREMENTS WITH THE UTILITY COMPANY PRIOR TO WORK.

2. ALL UTILITY METERS AT THE TRANSFORMER SHALL COMPLY WITH THE UTILITY STANDARDS.

3. PROVIDE A NEW 100A 480/277V ATS, TWO (2) 480V 3P 60A DISCONNECTS WITH 45 FUSES, TWO (2) 30KVA

TRANSFORMER, AND ONE (1) 100A 208/120V BRANCH PANEL FOR THE FIRE PUMP ROOM.

4. REFER TO THE SINGLE LINE DRAWING E-601-A FOR MORE INFORMATION.

5. FOR THE 75KW GENERATOR, CONTRACTOR TO PROVIDE AN ADDITIONAL FOUR (4) 225A 480V 3PH CIRCUIT

BREAKERS TO SERVE THE ANIMAL BUILDINGS.

LEGEND

BID OPTION #4

HYANG

Snapshot

S S

D

D

D

D

D

S4 S4

S3-4'

S3W-4'

S1

S1

S1

S1 S1

S1

S1

S1

S1 z36 z36 z37 z38 z38 z38 z38 z38 z38 z38 z38

" z37S3-2'

SB1 SB1 SB1

SB1

SB1

SB1

SB2SB2

SB1

SB2 SB2 SB2

z59 z59 z59 z59 z59 z59z59 z59 z59 z59z59z59

BOTTOM OF FIXTURE

SHALL BE MOUNTED 1'-6"

ABOVE THE TOP OF THE

SIGN

FIXTURES SHALL BE CENTERED

ON WALL PANEL. REFER TO

ARCHITECTURAL DRAWINGS

FOR PANEL SIZE AND LOCATION.

LP-1- 9 LP-1- 10

LP-1- 10

LP-1- 9

LP-1- 10

LP-1- 9

LP-1- 10

LP-1- 9

LP-1- 9

LP-1- 9

LP-1- 9

LP-1- 9

LP-1- 9

LP-1- 9

LP-1- 8 LP-1- 8 LP-1- 8

LP-1- 8

LP-1- 8

LP-1- 8

LP-1- 8 LP-1- 8

LP-1- 8

LP-1- 8LP-1- 8LP-1- 8

SB1

z59 z37

S1

LP-1- 9

DRAWING NOTES:

1. FOR ELECTRICAL SYMBOLS, ABBREVIATIONS

AND GENERAL NOTES, REFER TO DRAWINGS

E-001-A AND E-002-A.

2. FOR LIGHTING FIXTURE SCHEDULE, REFER TO

DRAWING EL-501-A AND EL-502-A. FOR LIGHTING

FIXTURE PLATES, REFER TO DRAWINGS EL-820-A

THROUGH EL-822-A

3. FOR LIGHTING DETAILS, REFER TO DRAWINGS

EL-801-A AND EL-802-A.

4. REFER TO REFLECTED CEILING PLANS FOR

FINAL AND EXACT LOCATION OF ALL CEILING

MOUNTED LIGHTING FIXTURES.

5. FOR LOW VOLTAGE LIGHTING CONTROL SYSTEM

RISERS AND DETAILS, REFER TO DRAWINGS

EL-611-A AND EL-612-A.

6. FOR LOW VOLTAGE LIGHTING CONTROL SYSTEM

SCHEDULES, REFER TO DRAWING EL-511-A.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

N E

W D

A

IR

Y F

O R

A G

E R

E S

E A

R C

H C

E N

T E

R

A u to d e s k D o c s /1

U

S D

A D

F R

C

/4

-E

-A R

E A

A -C e n tr a l.

rv t

/6

/2

:0

:4

P

M

ES-102

L

IG

H T

IN

G

S

IT

E P

L A

N

P R

A

IR

IE

D

U S

A C

W

I O

M A

H A

D

IS

T R

IC

T

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

D e s ig n e r

A u th o r

C h e c k e r

/0

/2

W F

C

W F

C

NORTH

KEY PLAN

A1" = 20'-0"1

LIGHTING SITE PLAN

1" = 20'-0"2

GUARD HOUSE

R T

A

/0

/2

FOR LOCATION OF CONTROL DEVICES

FOR THE SITE, REFER TO DRAWING

EL-110A

HYANG

Snapshot

XOO

PSL CR2

CR3

CR4

PSHH

OOX

MS

CR2

OOX

Aux

CR2

PSH

CR4 CR3

LSLL

CR3

LSL

CR4

OL

LSLL

LSL

Well

Level

Display

HAND – OFF -

AUTO

Pump Run

Command

High

Pressure

Lockout

Pump

Running

Auto Run

Command

Well Low

Level

Level

Transmitter

6.50

L N

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

N E

W D

A

IR

Y F

O R

A G

E R

E S

E A

R C

H C

E N

T E

R

A u to d e s k D o c s

/1 U

S D

A D

F R

C /4

-E

-A R

E A

A -C e n tr a l.

rv t

/1

/2

:5

:5

P

M

ES-103

B A

D G

E R

W E

L L

W

E L L P

U M

P D

IA

G

R A

M

P R

A

IR

IE

D

U S

A C

W

I O

M A

H A

D

IS

T R

IC

T

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

R A

Y M

O N

D G

A O

R A

Y M

O N

D G

A O

B E

N J A

M

IN

O M

E D

IC

H

W F

C

W F

C

R T

A

12" = 1'-0"1

WELL PUMP CONTROL PANEL DETAIL

/0 /2

/0

/2

V

AMP

CPU

T B

D

AL

TV

VP

VR

IC

IC

IC

C

F

M

M

M

S

SDR

S

V

S

S

VISUAL PAGE UNIT

CABLE TRAY OR WIREWAY

CENTRAL PROCESSING UNIT

BELL TRANSFORMER

DOOR CHIME AT +84"

AMPLIFIER ASSEMBLY WITH CONTROLS

OUTLET FOR DESK MOUNTED EQUIPMENT

REMOTE ALARM INDICATOR FOR ISOLATION TRANSFORMER AT +72"

MISC. COMMUNICATIONS

TV OUTLET. REQUIRES (1) CAT6-A CABLE AT +84" A.F.F.

COORDINATE WITHIN 6" OF ELECTRICAL OUTLET

VIDEO PLAYING/RECORDING EQUIPMENT OUTLET

VIDEO RECORDING EQUIPMENT OUTLET

TELEVISION DISTRIBUTION

MASTER INTERCOM STATION, DESK MOUNTED AND WALL MOUNTED OUTLET

AT +18"

MASTER INTERCOM STATION, WALL MOUNTED AT +48"

THE FOLLOWING SUBSCRIPTS ARE USED TO INDICATE THE VARIOUS TYPES

OF INTERCOMS

NO SUBSCRIPT - MASTER STATION WITHOUT HANDSET

S STAFF STATION

2 STAFF STATION CAPABLE OF CALLING TWO MASTERS

H MASTER STATION WITH HANDSET

M,S TWO-UNIT INTERCOM SYSTEM AT +48"

M=MASTER, S=SLAVE

INTERCOM STATION, PEDESTAL MOUNTED

INTERCOM

PUBLIC ADDRESS SPEAKER HORN AT +96"

VOLUME CONTROL FOR P.A. SPEAKER AT +48"

PUBLIC ADDRESS AUDIO SELECTOR SWITCH AT +48"

SOUND DISTRIBUTION RACK

MICROPHONE OUTLET AT +18"

MICROPHONE OUTLET CEILING MOUNTED

MICROPHONE OUTLET FLOOR MOUNTED

WALL MOUNTED PUBLIC ADDRESS SPEAKER

THE FOLLOWING SUBSCRIPTS ARE USED TO INDICATE THE VARIOUS TYPES

OF SPEAKERS

NO SUBSCRIPT - PUBLIC ADDRESS ONLY

M MUSIC ONLY

MP MUSIC AND PUBLIC ADDRESS

D DEPARTMENTAL AND GENERAL PAGING

2 TWO-WAY PUBLIC ADDRESS AND MONITORING

V INTEGRAL VOLUME CONTROL

PUBLIC ADDRESS

TV

VP

VR

TELECOMMUNICATIONS WIRED INFRASTRUCTURE

1. DRAWINGS FOR THIS WORK ARE DIAGRAMMATIC, INTENDED TO CONVEY THE

EXTENT, GENERAL ARRANGEMENT AND LOCATIONS OF THE WORK. BECAUSE OF

THE SCALE OF THE DRAWINGS, CERTAIN BASIC ITEMS SUCH AS CONDUIT FITTINGS,

ACCESS PANELS,CABINET SIZES, SLEEVES, PULL BOXES, BACKBOXES, AND

JUNCTION BOXES MAY NOT BE SHOWN. INCLUDE ALL ITEMS WHERE REQUIRED BY

CODE, OTHER SECTIONS, AND FOR PROPER INSTALLATION OF THE WORK.

2. ALL TELECOMMUNICATIONS WORK SHALL CONFORM TO ALL APPLICABLE NATIONAL,

STATE AND LOCAL BUILDING CODES AND SHALL BE IN COMPLIANCE WITH TIA/EIA.

3. DO NOT SCALE ANY DRAWINGS. DIMENSIONS TAKEN FROM CENTERLINE OF DEVICE

OR GANG BOX SHALL BE FOLLOWED. TELECOMMUNICATIONS DEVICES ARE SHOWN

FOR LOCATION ONLY.

4. INCLUDE SUCH ITEMS AS REQUIRED FOR A COMPLETELY OPERATIONAL AND FULLY

FUNCTIONAL CONDUIT SYSTEM, WHETHER OR NOT SPECIFICALLY INDICATED.

5. PROVIDE CONDUIT IN ACCORDANCE WITH THE N.E.C., N.F.P.A. AND DIVISIONS 26

AND 27 OF THE SPECIFICATIONS.

6. ALL OUTLET BOXES, JUNCTION BOXES AND PULL BOXES SHALL BE FURNISHED,

INSTALLED AND LABELED BY THE CONTRACTOR AS REQUIRED.

7. ALL COMMUNICATIONS OUTLET BOXES THAT ARE EMPTY AT THE COMPLETION OF

WORK SHALL HAVE A MINIMUM 1" CONDUIT HOMERUN TO CABLE TRAY SYSTEM

WITH PULL-STRING HAVING MINIMUM TEST RATING OF 200 LB.

8. SHOULD JOB CONDITIONS REQUIRE RELOCATION OF PLANNED OUTLET BOXES, THE

INSTALLER SHALL NOTIFY THE OWNER FOR APPROVAL OF ALTERNATE LOCATION

PRIOR TO THE START OF ANY WORK.

9. CONSTRUCTION MANAGER SHALL COORDINATE FINAL LOCATION FOR OWNER

SUPPLIED CONTRACTOR INSTALLED EQUIPMENT IF REQUIRED.

10. COORDINATE WALL COMMUNICATION OUTLET LOCATIONS WITH POWER OUTLETS

AND FURNITURE TO BE INSTALLED ON WALL OR SYSTEMS FURNITURE.

11. ALL COMMUNICATIONS CONDUIT RUNS, CELLS OR INNERDUCT, REMAINING EMPTY

AT THE TIME OF COMPLETED CONSTRUCTION SHALL BE EQUIPPED WITH A PULL-

STRING HAVING MINIMUM TEST RATING OF 200 LB.

12. NO ONE CONDUIT SEGMENT SHALL BE MORE THAN 100' WITHOUT THE INSERTION

OF A PULL BOX.

13. ALL CONDUIT AND BOXES SHALL BE INSTALLED IN ACCORDANCE WITH DIVISION 26

SPECIFICATIONS. REFER TO SECTIONS 26 20 00 FOR SPECIFIC CONDUIT BONDING

DETAILS.

14. EMT CONDUIT SHALL BE ELECTRICAL METALLIC TUBING MEETING ANSI C80.3 AND

SHALL BE 1” MINIMUM SIZE FOR BOX LOCATIONS UNLESS OTHERWISE NOTED.

15. FLEXIBLE METAL CONDUIT (FMC) IS NOT ACCEPTABLE.

16. OUTLET BOXES SHALL BE A MINIMUM OF 4 11/16 X 4 11/16 X 2 5/8 INCHES IN SIZE

WITH EXTENSION RINGS (AS NEEDED), A SINGLE GANG MUD RING MATCHING THE

THICKNESS OF THE FINISHED WALL MATERIAL/COVERING AND A SINGLE GANG

COVER TO MATCH THE TYPE REQUIRED AT THE SPECIFIC OUTLET ASSEMBLY.

17. JUNCTION BOXES AND PULL BOXES SHALL BE STAMPED STEEL, DEEP DRAWN ONE

PIECE (WITHOUT WELDS OR TAB CONNECTIONS), GALVANIZED, WITH KNOCKOUTS

FOR CONDUIT OR CONNECTOR ENTRANCE.

18. BOXES 6" x 6" x 4" OR LARGER MAY BE COLD GAUGE FABRICATED STEEL

CONTINUOUSLY WELDED AT SEAMS AND PAINTED AFTER FABRICATION.

19. FIRE STOPPING SHALL CONFORM TO BOTH FLAME (F) AND TEMPERATURE (T)

RATINGS AS REQUIRED BY LOCAL BUILDING CODES.

20. LABELS SHALL BE AS RECOMMENDED IN ANSI/TIA/EIA 606.

21. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE NATIONAL

ELECTRICAL SAFETY CODE (NESC) AND THE NEC.

22. INSTALL RACEWAYS, BOXES, ENCLOSURES, AND CABINETS AS INDICATED AND

ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS AND

RECOMMENDATIONS.

23. RUN PARALLEL OR BANKED CONDUITS TOGETHER, ON COMMON SUPPORTS WHERE

PRACTICAL AND ALLOWED BY SECURITY STANDARDS AND N.E.C.

24. WHERE CONDUITS CROSS BUILDING EXPANSION JOINTS, USE SUITABLE SLIDING OR

OFFSETTING EXPANSION FITTINGS.

25. DO NOT EXCEED 180 DEGREES FOR THE SUM TOTAL OF CONDUIT SWEEPS

BETWEEN CONDUIT TERMINATION POINTS FOR A SECTION OF CONDUIT.

26. ALL CONDUIT FIELD BENDS SHALL BE PROVIDED AS PART OF INSTALLATION

PROCESS.

27. MATCH STANDARD COMMUNICATIONS OUTLET MOUNTING HEIGHT WITH ELCTRICAL

OUTLET HEIGHT UNLESS OTHERWISE NOTED.

28. ALL VIDEO DISPLAYS REQUIRE A 120V QUAD OUTLET AND DATA OUTLETS WITH LAN

CONNECTIVITY.

29. ALL AUDIO VIDEO DEVICES AND SYSTEMS SHALL BE INSTALLED IN ACCORDANCE

WITH THE N.E.C AND DIVISION 26 AND 27 OF THE SPECIFICATION.

TELECOM GENERAL NOTESABBREVIATIONS

NOTE:

SYMBOLS SHOWN ARE FOR REFERENCE ONLY

AND DO NOT CONSTITUTE A CHECK LIST OF

DEVICES REQUIRED BY THE CONTRACT

TYPICAL OUTLET SYMBOL NOTES

"+" -MOUNTED 4" ABOVE COUNTER, CASEWORK, BACKSLASH OR 48" IF NOTHING BELOW.

COORDINATE WITH ARCHITECTURAL DETAILS AND CASEWORK CONTRACTOR.

"+84" -INDICATES MOUNTING HEIGHT ABOVE FINISHED FLOOR.

NOTES

1. OUTLETS LOCATED AT COUNTERS SHALL BE LOCATED 18" AFF IN KNEE SPACE IF

PROVIDED OR 4" ABOVE COUNTER OR BACK SPLASH AS APPLICABLE IF NO KNEE SPACE IS

PROVIDED U.O.N.

2. # = SUBSCRIPT TO INDICATE VARIOUS OUTLET TYPES.

STANDARD TELE/DATA OUTLET. WALL MOUNTED REQUIRES (4) CAT6-A

CABLES. PROVIDE 1" CONCEALED CONDUIT TO 6" ABOVE ACCESSIBLE

CEILING, UON.

STANDARD DATA OUTLET. WALL MOUNTED REQUIRES (1) CAT6-A CABLE.

PROVIDE 1" CONCEALED CONDUIT TO 6" ABOVE ACCESSIBLE CEILING, UON.

STANDARD VOICE OUTLET. WALL MOUNTED REQUIRES (1) CAT6-A CABLE.

PROVIDE 1" CONCEALED CONDUIT TO 6" ABOVE ACCESSIBLE CEILING, UON.

FLOOR OUTLET. REQUIRES (1) 1 1/2" CONDUIT TURN UP TO ACCESSIBLE

CEILING AS SHOWN ON FLOOR PLAN UON. PATHWAY PROVIDED BY

ELECTRICAL CONTRACTOR. REFER TO ELECTRICAL DRAWINGS AND

SCHEDULE FOR REQUIREMENTS.

PATHWAYS AND CABLE

WP

E

P

OUTLET FOR ELEVATOR SYSTEM. COORDINATE EXACT LOCATION AND

REQUIREMENT WITH ELEVATOR CONTRACTOR.

OUTLET MOUNTED IN NEMA 4X RATED WEATHER PROOF

PUBLIC

STANDARD TELE/DATA OUTLET. CEILING MOUNTED REQUIRES (2) CAT6-A

CABLES. PROVIDE 1" CONCEALED CONDUIT TO 6" ABOVE ACCESSIBLE CEILING,

UON.

STANDARD DATA OUTLET. CEILING MOUNTED REQUIRES (1) CAT6-A CABLE.

PROVIDE 1" CONCEALED CONDUIT TO 6" ABOVE ACCESSIBLE CEILING, UON.

CEILING MOUNTED PUBLIC ADDRESS SPEAKER

J

J

FLOOR JUNCTION BOX. REQUIRES 1" CONDUIT TURN UP TO ACCESSIBLE

CEILING AS SHOWN ON FLOOR PLAN UON.

WALL MOUNTED JUNCTION BOX. SIZE TO SUPPORT ACTUAL AMOUNT OF

CABLE PROVIDED PLUS AN ADDITIONAL 25% SPARE CAPACITY.

CEILING MOUNTED WIRELESS ACCESS POINT DATA OUTLET IN

ENCLOSURE. REQUIRES (2) CAT6-A CABLES.

F REFRIGERATION MONITORING

M MEDICAL EQUIPMENT

VIDEO TELECONFERENCE WALL ASSEMBLY LOCATION.

R AREA OF REFUGE

TV

VTC

J FLOOR MOUNTED JUNCTION BOX. SIZE TO SUPPORT ACTUAL AMOUNT OF

CABLE PROVIDED PLUS AN ADDITIONAL 25% SPARE CAPACITY.

SP CEILING MOUNTED PROGRAM AUDIO SPEAKER

AWG AMERICAN WIRE GAUGE

C CONDUIT

CCTV CLOSED CIRCUIT TELEVISION

HSS HIGH SECURITY SWITCH

GFCI GOVERNMENT FURNISHED, CONTRACTOR INSTALL

GRD, GND, G GROUND

JB JUNCTION BOX

MH MANHOLE

N.C. NORMALLY CLOSED

NEC NATIONAL ELECTRICAL CODE

NIC NOT IN CONTRACT

N.O. NORMALLY OPEN

NTS NOT TO SCALE

PB PULLBOX

PNL PANEL

POP POINT OF PRESENCE

PP PATCH PANEL

PVC POLYVINYL CHLORIDE

PWR POWER

RGS RIGID GALVANIZED STEEL CONDUIT

TEL TELEPHONE

SBB SECONDARY BONDING

TV TELEVISION

TYP TYPICAL

UG UNDERGROUND

UON UNLESS OTHERWISE NOTED

VDC VOLTAGE DIRECT CURRENT

VLAN VIRTUAL LOCAL AREA NETWORK

WAN WIDE AREA NETWORK

GFI, GF GROUND FAULT INTERRUPTER

PBB PRIMARY BONDING

PS POWER SUPPLY

TX TRANSCEIVER

UPS UNINTERRUPTIBLE POWER SUPPLY

UTP UNSHIELDED TWISTED PAIR

W WATTS OR WIRE

W/ WITH

W/O WITHOUT

WP WEATHERPROOF

VAC VOLTAGE ALTERNATING CURRENT

WS WORK STATION

ACS ACCESS CONTROL SYSTEM

ACP ACCESS CONTROL PANEL

A AMPERE

SEC SECURITY EQUIPMENT CABINET

SRV SERVER SLAN SECURITY LOCAL AREA NETWORK

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

BFC BELOW FINISHED CEILING

DPS DOOR POSITION SWITCH

EMT ELECTRICAL METALLIC TUBING (CONDUIT)

ESS ELECTRONIC SECURITY SYSTEM

GC GENERAL CONTRACTOR

REX REQUEST TO EXIT

GFGI GOVERNMENT FURNISHED, GOVERNMENT INSTALL

CFCI CONTRACTOR FURNISHED, CONTRACTOR INSTALL

SLAN SECURITY LOCAL AREA NETWORK

HH HANDHOLE (NOT TO SCALE)

TC TELECOM WALL MOUNTED CABINET (NOT TO SCALE)

TC TELECOM WALL MOUNTED CABINET

POE POWER OVER ETHERNET

TER TELECOMMUNICATIONS EQUIPMENT ROOM (NOT TO SCALE)

FACP FIRE ALARM CONTROL PANEL

FIRE ALARM CONTROL PANEL (NOT TO SCALE)

FACP

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

N E

W D

A

IR

Y F

O R

A G

E R

E S

E A

R C

H C

E N

T E

R

A u to d e s k D o c s

/1 U

S D

A D

F R

C /4

-T

-A L L -C e n tr a l.

rv t

/4

/2

:2

:2

P

M

T-001

T E

L E

C O

M M

U N

IC

A

T

IO

N S

L E

G E

N D

P R

A

IR

IE

D

U S

A C

W

I O

M A

H A

D

IS

T R

IC

T

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

J .F

A L L O

N

J .H

E S

S L E

R

D .R

O B

E R

T S

/0

/2

W F

C

W F

C

R T

A

/0

/2

A. LAB & ADMIN

B1. ANIMAL EMISSIONS CHAMBERS

B2. ADVANCED ANIMAL NUTRITION

B3.1. CONVENTIONAL FREESTALL

B3.2. DRY COWS

B4. MILKING PARLOR

B5. SPECIAL NEEDS & MATERNITY

B6. ROBOTIC FREESTALL

B7. CALF BARN

B8. PESTICIDE BUILDING

B9. FEED MIXING

B10.1. BAG STORAGE (OPEN)

B10.2. BUNKER STORAGE (OPEN)

B10.3. HAY STORAGE (GRAVEL PAD)

B11.1. SHOP

B11.2. MACHINE STORAGE

B13. MILK HOUSE

B14. FUEL STORAGE

B15. COMMODITY

C1. LIQUID WASTE STORAGE FACILITY CELL

C2. SOLID STACK BUILDING

C3. SOLIDS/SAND SEPARATION FACILITY

C4. LEACHATE COLLECTION

E1. SMALL EQUIPMENT BLDG (EXISTING, NIC)

E2. CONSERVATION CLUB (EXISTING, NIC)

BUILDINGS:

A

B1 B2 B3.1

C2

C3

B10

B14

B15 B6

B13

B12.2

B9

B4

E2

E1

B8

B5

B12.1

B7

FIRE PUMP

C1 C1

B3.2

B11.2

B11.1

C4

A. BID OPTION 4

GENERAL NOTES:

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

PLAN

N E

W D

A

IR

Y F

O R

A G

E R

E S

E A

R C

H C

E N

T E

R

A u to d e s k D o c s

/1 U

S D

A D

F R

C /4

-T

-A L L -C e n tr a l.

rv t

/5

/2

:5

:2

P

M

T-100

T E

L E

C O

M M

U N

IC

A

T

IO

N S

S

IT

E P

L A

N

P R

A

IR

IE

D

U S

A C

W

I O

M A

H A

D

IS

T R

IC

T

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

J .F

A L L O

N

J .H

E S

S L E

R

D .R

O B

E R

T S

/0

/2

W F

C

W F

C

NORTH

KEY PLAN

A B1

B8

B2

B3

B4 B5 B13

B6 B9

B15

B7

B11

B10

C2

C4

C3 C1

B14B12.1

B12.2

0 50' 100' 200'

1" = 100'-0"A1

TELECOMMUNICATIONS SITE PLAN

R T

A

/0

/2

HH

TC

HH

HHHHHH

TERHHHH

HH

TC

TC

TCTC

TC

TC

2 2

2 2

NOTE:

BUILDING CONTRACTOR TO COORDINATE

INCOMING OSP CONDUIT AND FIBER WITH

SERVICE PROVIDER.

A

B1 B2 B3.1

C3

B6

B13

B12.2

B4

E2

E1

B8

B5

B12.1

C1

C1

B3.2

1. (1) 4'X4'X4' HANDHOLE.

2. (2) 4" PVC CONDUITS INSTALLED IN

COMPACTED SOIL BACKFILL, W/ 6 CELL

FABRIC MESH INNERDUCT.

3. (1) 3" PVC CONDUIT INSTALLED IN

COMPACTED SOIL BACKFILL, W/ 3 CELL

FABRIC MESH INNERDUCT. 3" PVC

CONDUIT TO BE COVERTED TO A

GALVANIZED 3" RIGID CONDUIT AT THE

FACILITY INTO THE TELECOM CABINET

(TC).

KEY NOTES:

A. OSP PATHWAYS SHOWN IN DRAWING

ARE DIAGRAMMATIC AND SHALL BE

COORDINATED WITH ALL OTHER CIVIL

DISCIPLINES.

B. HANDHOLES TO BE PLACED AT A

MINIMUM OF 600 FOOT.

C. SERVICE PROVIDER POP, OUTSIDE

PLANT PATHWAY, AND FIBER CABLE

DESIGN WORK IN PROGRESS.

D. BID OPTION 4.

GENERAL NOTES:

A. LAB & ADMIN

B1. ANIMAL EMISSIONS CHAMBERS

B2. ADVANCED ANIMAL NUTRITION

B3.1. CONVENTIONAL FREESTALL

B3.2. DRY COWS

B4. MILKING PARLOR

B5. SPECIAL NEEDS & MATERNITY

B6. ROBOTIC FREESTALL

B7. CALF BARN

B8. PESTICIDE BUILDING

B9. FEED MIXING

B10.1. BAG STORAGE (OPEN)

B10.2. BUNKER STORAGE (OPEN)

B10.3. HAY STORAGE (GRAVEL PAD)

B11.1. SHOP

B11.2. MACHINE STORAGE

B13. MILK HOUSE

B14. FUEL STORAGE

B15. COMMODITY

C1. LIQUID WASTE STORAGE FACILITY CELL

C2. SOLID STACK BUILDING

C3. SOLIDS/SAND SEPARATION FACILITY

C4. LEACHATE COLLECTION

E1. SMALL EQUIPMENT BLDG (EXISTING, NIC)

E2. CONSERVATION CLUB (EXISTING, NIC)

BUILDINGS:

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

PLAN

N E

W D

A

IR

Y F

O R

A G

E R

E S

E A

R C

H C

E N

T E

R

A u to d e s k D o c s

/1 U

S D

A D

F R

C /4

-T

-A L L -C e n tr a l.

rv t

/5

/2

:5

:2

P

M

T-100.1

T E

L E

C O

M M

U N

IC

A

T

IO

N S

S

IT

E P

L A

N

W E

S T

P R

A

IR

IE

D

U S

A C

W

I O

M A

H A

D

IS

T R

IC

T

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

J .F

A L L O

N

J .H

E S

S L E

R

D .R

O B

E R

T S

/0

/2

W F

C

W F

C

NORTH

KEY PLAN

A B1

B8

B2

B3

B4 B5

B6

C3 C1

1" = 60'-0"A1

TELECOMMUNICATIONS SITE PLAN - WEST

0 30' 60' 120'

TC

HH

HH

HH TC

TC

HH

TC

2 2

C2

B10

B14

B15

B9

B7

FIRE PUMP

B11.2

B11.1

C4

A. OSP PATHWAYS SHOWN IN DRAWING

ARE DIAGRAMMATIC AND SHALL BE

COORDINATED WITH ALL OTHER CIVIL

DISCIPLINES.

B. HANDHOLES TO BE PLACED AT A

MINIMUM OF 600 FOOT.

C. SERVICE PROVIDER POP, OUTSIDE

PLANT PATHWAY, AND FIBER CABLE

DESIGN WORK IN PROGRESS.

D. BID OPTION 4.

GENERAL NOTES:

A. LAB & ADMIN

B1. ANIMAL EMISSIONS CHAMBERS

B2. ADVANCED ANIMAL NUTRITION

B3.1. CONVENTIONAL FREESTALL

B3.2. DRY COWS

B4. MILKING PARLOR

B5. SPECIAL NEEDS & MATERNITY

B6. ROBOTIC FREESTALL

B7. CALF BARN

B8. PESTICIDE BUILDING

B9. FEED MIXING

B10.1. BAG STORAGE (OPEN)

B10.2. BUNKER STORAGE (OPEN)

B10.3. HAY STORAGE (GRAVEL PAD)

B11.1. SHOP

B11.2. MACHINE STORAGE

B13. MILK HOUSE

B14. FUEL STORAGE

B15. COMMODITY

C1. LIQUID WASTE STORAGE FACILITY CELL

C2. SOLID STACK BUILDING

C3. SOLIDS/SAND SEPARATION FACILITY

C4. LEACHATE COLLECTION

E1. SMALL EQUIPMENT BLDG (EXISTING, NIC)

E2. CONSERVATION CLUB (EXISTING, NIC)

BUILDINGS:

1. (1) 4'X4'X4' HANDHOLE.

2. (2) 4" PVC CONDUITS INSTALLED IN

COMPACTED SOIL BACKFILL, W/ 6 CELL

FABRIC MESH INNERDUCT.

3. (1) 3" PVC CONDUIT INSTALLED IN

COMPACTED SOIL BACKFILL, W/ 3 CELL

FABRIC MESH INNERDUCT. 3" PVC

CONDUIT TO BE COVERED TO A

GALVANIZED 3" RIGID CONDUIT AT THE

FACILITY INTO THE TELECOM CABINET

(TC).

4. (1) 3" PVC CONDUIT INSTALLED IN

COMPACTED SOIL BACKFILL, W/3 CELL

FABRIC MESH INNERDUCT. 3" PVC

CONDUIT TO BE COVERED TO

GALVANIZED 3" RIGID CONDUIT, LOCATE

AT THE FIRE PANEL.

5. (1) 4 STRAND SINGLE MODE FIBER DROP

OSP RATED TERMINATED WITH LC

CONNECTORS ROUTED FROM FIRE

PANEL TO B11-TC FIBER PANEL.

KEY NOTES:

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

PLAN

N E

W D

A

IR

Y F

O R

A G

E R

E S

E A

R C

H C

E N

T E

R

A u to d e s k D o c s

/1 U

S D

A D

F R

C /4

-T

-A L L -C e n tr a l.

rv t

/5

/2

:5

:3

P

M

T-100.2

T E

L E

C O

M M

U N

IC

A

T

IO

N S

S

IT

E P

L A

N

E A

S T

P R

A

IR

IE

D

U S

A C

W

I O

M A

H A

D

IS

T R

IC

T

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

J .F

A L L O

N

J .H

E S

S L E

R

D .R

O B

E R

T S

/0

/2

W F

C

W F

C

NORTH

KEY PLAN

B9 B15

B7

B11

B10

C2

B14

1" = 60'-0"D4

TELECOMMUNICATIONS SITE PLAN - EAST

0 30' 60' 120'

R T

A

/0

/2

LEGEND

TELECOMMUNICATIONS PRIMARY BONDING BUSBAR

TELECOMMUNICATIONS SECONDARY BONDING BUSBAR

ELECTRICAL MAIN OR SUB PANEL

BUILDING STEEL - BONDING CONDUCTOR

EQUIPMENT & HARDWARE - BACKBONE BONDING CONDUCTOR

ELECTRICAL MAIN-PANEL - BONDING CONDUCTOR

ELECTRICAL SUB-PANEL - BONDING CONDUCTOR

MAIN CROSS-CONNECT / ENTRANCE FACILITY

MAIN ELECTRICAL ROOM / ELECTRICAL ENTRANCE FACILITY

BS

EH

EM

ES

MC/EF

MER/EEF

NOTES

ALL TBBS, GE, AND THE BONDING CONDUCTOR FOR TELECOMMUNICATIONS

GROUNDING SYSTEM ARE TO BE 3/0 AWG.

ALL BUILDING STEEL, TELECOMMUNICATIONS ELECTRONICS & HARDWARE,

AND ELECTRICAL SUB-PANEL BONDING CONDUCTORS ARE TO BE MINIMUM

No. 4-AWG.

THE PBB & ALL SBBs SHALL BE COMPLIANT TO THE FOLLOWING STANDARD J-

STD-607-D COMMERCIAL BUILDING GROUNDING (EARTHING) AND BONDING

REQUIREMENTS FOR TELECOMMUNICATIONS.

FURNISH ONLY UL-LISTED HARDWARE AND CONNECTORS.

ONLY LISTED COMPRESSION TYPE - TWO-HOLE LUGS SHALL BE INSTALLED

ON ALL GROUNDING BUSBARS.

JOINED TBB SEGMENTS SHALL BE CONNECTED USING IRREVERSIBLE C-TYPE

COMPRESSION TAPS.

ALL GROUNDING & BONDING BUSBARS AND CONDUCTORS SHALL BE TAGGED

AND ALSO CONTAIN A WIRE WRAPPED IDENTIFIER.

MER/EEFMC/EF

PBB

BS

EH

BONDING CONDUCTOR TO MAIN ELECTRICAL

PANEL FOR TELECOMMUNICATIONS GROUNDING

SYSTEM

EH

BS

SBB

EH

BS

SBB

EH

BS

SBB

TBB - TELECOMMUNICATIONS BONDING BACKBONE

U L

LISTED

Shown Connecting Two

Copper Conductors

TBB to TGB BONDING DETAIL

PBB to TGB BONDING CLAMP DETAIL

U L

LISTED

All Bonding Conductors attaching to Busbars

BONDING CONDUCTOR TAG &

LABEL DETAIL

WIRE

WIRE

CLEAR TAIL

CLEAR

TAIL

WIRE WIRE

WIRE WIRE

WARNING

IF THIS CONNECTOR OR CABLE IS

LOOSE OR MUST BE REMOVED,

PLEASE CALL THE BUILDING

TELECOMMUNICATIONS MANAGER

INFO

INFO

INFO

+ WHEN COPPER PIPE IS USED, T RATING IS 0 HR. MINNESOTA

MINING & MFG.

CO. - CP 25WB+. * BEARING THE UL CLASSIFICATION MARKING

(FORMERLY SYSTEM NO. 147)

F RATINGS- 1, 2, 3 AND 4 HR (SEE ITEMS 2 & 3)

T RATING -0 1, 2, 3 & 4 HR (SEE ITEM 3)

L RATING AT AMBIENT-LESS THEN 1 CFM/SQ FT.

L RATING AT 400 F-LESS THEN 1 CFM/SQ FT.

A

A

FIRE STOPPING SYSTEM NO.C-AJ-009/UL-318

1A

2 3

1. WALL ASSEMBLY - THE 1,2,3 OR 4 HR. FIRE-RATED GYPSUM

WALLBO/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE

MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300

OR U400 SERIES WALL OR PARTITION DESIGNS IN THE UL FIRE

RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING

CONSTRUCTION FEATURES:

A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD

STUDS (MAX 2HR. FIRE RATED ASSEMBLIES) OR STEEL

CHANNEL STUDS, WOOD STUDS TO CONSIST OF NOM. 2 BY 4

IN. LUMBER SPACED 16 IN. OC WITH NOM 2 BY 4 IN. LUMBER

END PLATES AND CROSS BRACES. STEEL STUDS TO BE MIN.

3-5/8" WIDE BY 1-3/8" DEEP CHANNELS SPACED MAX 24 IN. OC.

B. GYPSUM BOARD* - NOM 1/2" OR 5/8" THICK, 4 FT. WIDE WITH

SQUARE OR TAPERED EDGES. THE GYPSUM WALLBOARD

TYPE, THICKNESS, NUMBER OF LAYERS, FASTENER TYPE AND

SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE

INDIVIDUAL U300 OR U400 SERIES DESIGN IN THE UL FIRE

RESISTANCE DIRECTORY. MAX DI. OF OPENING IS 13-1/2".

2. PIPE OR CONDUIT - NOM 12" DIAM. (OR SMALLER ) SCHEDULE 10 (OR

HEAVIER) STEEL PIPE, NOM 12" DIAM. (OR SMALLER) SERVICE WEIGHT

(OR HEAVIER) CAST IRON SOIL PIPE, NOM 12" DIAM. (OR SMALLER)

CLASS 50 (OR HEAVIER) DUCTILE IRON PRESSURE PIPE, NOM 6" DIAM.

(OR SMALLER) STEEL CONDUIT, NOM 4" DIAM. (ORSMALLER) STEEL

ELECTRICAL METALLIC TUBING, NOM 6" DIAM. (OR SMALLER) TYPE L

OR (OR HEAVIER) COPPER TUBING OR NOM 1" DIAM. (OR SMALLER)

FLEXIBLE STEEL CONDUIT. WHEN COPPER PIPE IS USED, MAX F

RATING OF FIRESTOP SYSTEM (ITEM 3) IS 2 HR. STEEL PIPES OR

CONDUITS LARGER THAN NOM 4" DIAM. MAY ONLY BE USED IN WALLS

CONSTRUCTED USING STEEL CHANNEL STUDS. A MAX OF ONE PIPE

OR CONDUIT IS PERMITTED IN THE FIRESTOP SYSTEM. PIPE OR

CONDUIT TO BE INSTALLED NEAR CENTER OF STUD CAVITY WIDTH

AND TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY.

3. FILL, VOID CAVITY MATERIAL* - CAULK-CAULK FILL MATERIAL

INSTALLED TO COMPLETELY FILL ANNULAR SPACE BETWEEN PIPE OR

CONDUIT AND GYPSUM WALLBOARD AND WITH A 1/4" MIN. DIAM. BEAD

OF CAULK APPLIED TO PARAMETER OF PIPE OR CONDUIT AT ITS

EGRESS FROM THE WALL. CAULK INSTALLED SYMMETRICALLY ON

BOTH SIDES OF THE WALL ASSEMBLY. THE HOURLY F RATING OF THE

FIRESTOP SYSTEM IS DEPENDENT UPON THE HOURLY FIRE RATING

OF WALL ASSEMBLY IN WHICH IT IS INSTALLED, AS SHOWN IN THE

FOLLOWING TABLE. THE HOURLY RATING OF THE FIRESTOP SYSTEM

DEPENDENT UPON THE TYPE OR SIZE OF THE PIPE OR CONDUIT AND

THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS

INSTALLED, AS TABULATED BELOW:

A

A

SECTION A-A

1A 1B

THROUGH-PENETRATION FIRESTOP SYSTEMS

F RATINGS - 1, 2 ,3 AND 4 HR. (SEE ITEM 3)

T RATINGS - 3/4 AND 1 HR. (SEE ITEM 3)

L RATINGS AT AMBIENT- 4 OR 7 CFM (SEE ITEM 3)

L RATINGS AT 400F- 2 OR 3 CFM (SEE ITEM 3)

1. WALL ASSEMBLY - THE 1, 2, 3, OR 4 HR FIRE-RATED GYPSUM BOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED WITHIN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCORPORATE THE

FOLLOWING CONSTRUCTION FEATURES:

A. STUDS - WALL FRAMING SHALL CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4". LUMBER

SPACED MAX 16" O.C. STEEL STUDS TO BE MIN 3 1/2" WIDE AND SPACED MAX 24" O.C.

B. GYPSUM BOARD* - THICKNESS, TYPE, NUMBER OF LAYERS AND FASTENERS AS SPECIFIED IN THE INDIVIDUAL WALL AND PARTITION DESIGN. OPENING IN

GYPSUM BOARD TO ME MAX 16.35MM LARGER THEN WIDTH AND HEIGHT DIMENSIONS OF FIRESTOP DEVICE(S).

THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE HOURLY RATING OF THE WALL IN WHICH IT IS INSTALLED.

2. FIRESTOP SYSTEM - ONE, TWO, THREE, FOUR OR SEVEN FIRESTOP DEVICE MODULES GANGED TOGETHER. EACH FIRESTOP DEVICE MODULE CONSISTS OF A 3 BY 3" BY 10 1/2" LONG GALV STEEL TUBE WITH AN INTUMESCENT MATERIAL LINING. FIRESTOP DEVICE MODULES TO BE INSTALLED IN ACCORDANCE WITH THE ACCOMPANYING INSTALLATION INSTRUCTIONS. THE SPACE BETWEEN THE FIRESTOP DEVICE MODULE(S) AND THE PERIPHERY OF THE OPENING SHALL BE MIN 0 TO MAX 1/8". FIRESTOP DEVICE MODULE(S) SECURED IN PLACE BY MEANS OF STEEL WALL PLATES INSTALLED WITH GASKETING MATERIAL SUPPLIED WITH PRODUCT.

STEEL WALL PLATES INSTALLED ON BOTH SIDES OF WALL AND SECURED TO EACH DEVICE BY MEANS OF STEEL SET SCREWS PROVIDED WITH DEVICE. EACH FOUR- AND-SEVEN-GANG STEEL WALL PLATE SHALL BE FASTENED TO THE STUDS WITH STEEL SCREWS SIZED TO EXTEND THROUGH THE GYPSUM BOARD LAYERS AND PENETRATE 1/2" INTO THE FRAMING MEMBER. EACH FIRESTOP DEVICE MODULE IS TO BE INSTALLED WITH ENDS PROJECTING AN EQUAL DISTANCE BEYOND EACH SURFACE OF THE WALL ASSEMBLY. AS AN ALTERNATE, THE FOUR-AND-SEVEN-GANG STEEL WALL PLATES MAY BE INSTALLED DIRECTLY AGAINST THE STUDS FOR WALLS HAVING 16 AND 24" CENTER-T0-CENTER STUD SPACING, RESPECTIVELY, PRIOR TO INSTALLATION OF THE GYPSUM BOARD LAYERS. THE STEEL WALL PLATES SHALL BE SECURED TO THE STUD BY MEANS OF STEEL SCREWS. AFTER INSTALLATION OF THE STEEL WALL PLATES AND FIRESTOP DEVICE MODULES.

THE GYPSUM BOARD SHALL BE INSTALLED AS SPECIFIED IN THE INDIVIDUAL U300 OR U400 DESIGN WITH A MAXIMUM OF 1/8" GAP BETWEEN THE FIRESTOP DEVICE MODULE AND THE CUTOUT IN THE GYPSUM BOARD. GAP BETWEEN THE FIRESTOP DEVICE MODULE AND THE CUTOUT IN THE GYPSUM BOARD MAY BE FILLED

WITH GYPSUM JOINT COMPOUND OR FILL MATERIAL (ITEM 4).

3. CABLES - WITHIN THE LOADING AREA FOR EACH FIRESTOP DEVICE MODULE, THE CABLES MAY REPRESENT A 0 TO 100% VISUAL FILL. CABLE FILL TO BE DISTRIBUTED AT A UNIFORM HEIGHT ACROSS THE WIDTH OF THE FIRESTOP DEVICE MODULE. CABLES TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF THE WALL

ASSEMBLY. ANY COMBINATION OF THE FOLLOWING TYPES OF CABLES MAY BE USED:

A. MAX 400 PAIR NO. 24 AWG (OR SMALLER) COPPER CONDUCTOR TELECOMMUNICATION CABLE WITH POLYVINYL CHLORIDE (PVC) JACKETING AND

INSULATION.

B. MAX 4 PAIR NO. 22 AWG (OR SMALLER) COPPER CONDUCTOR DATA CABLE WITH PVC OR PLENUM RATED JACKETING AND INSULATION.

C. MAX RG/U COAXIAL CABLE WITH FLUORINATED ETHYLENE INSULATION JACKETING.

D. FIBER OPTIC CABLE WITH PVC OR POLYETHYLENE (PE) JACKET AND INSULATION HAVING A MAX DIA OF 5/8".

E. OPTICAL FIBER RACEWAY + - MAX 1 1/2" DIA (OR SMALLER) OPTICAL FIBER RACEWAY ("INNERDUCT") FORMED OF EITHER PVC OR POLYVINYLIDENE

FLUORIDE (PVDF) WITH OPTICAL FIBER CABLE FILL. RACEWAYS INSTALLED IN ACCORDANCE WITH THE ARTICLE 770 OF THE NATIONAL ELECTRICAL CODE (NFPA 70) WHEN ITEM 3A IS USED, THE MAX SIZE OF CABLE IS 200 PAIR FOR THE 4 HR F RATING. OTHERWISE THE F RATING IS 2 HR. WHEN THE HOURLY RATING OF THE WALL ASSEMBLY IS 1 HR, THE T RATING IS 3/4 HR. WHEN THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IS 2, 3 OR 4 HR, THE T RATING IS 3/4 HR WHEN ITEM 3A IS USED. OTHERWISE THE T RATING IS 1 HR. WHEN ITEM 3A IS USED, THE L RATING FOR EACH FIRESTOP DEVICE MODULE WITH 100% VISUAL FILL OF CFM AT AMBIENT AND 3 CFM AT 400F. WHEN ITEM 3B, 3C OR 3D IS USED, THE L RATING FOR EACH FIRESTOP DEVICE

MODULE WITH 100% VISUAL FILL OF CABLE IS 7 CFM AT AMBIENT AND 2 CFM AT 400F.

4. FILL, VOID OR CAVITY MATERIAL* - SEALANT OR PUTTY - (NOT SHOWN) - AS AN ALTERNATE TO GYPSUM JOINT COMPOUND, THE GAP BETWEEN THE FIRESTOP DEVICE MODULE AND THE CUTOUT IN THE GYPSUM BOARD MAY BE SEALED WITH THE FILL MATERIAL ON EACH SIDE OF THE WALL ASSEMBLY WHEN FOUR-AND- SEVEN-GANG STEEL WALL PLATES ARE INSTALLED DIRECTLY AGAINST THE WOOD OR STEEL STUDS.

*BEARING THE UL CLASSIFICATIONS MARK

NOTES:

H2O RATED HAND HOLE ACCESS

COVER, FRAME AND COLLAR.

REINFORCED PRECAST

CONCRETE BOX AND TOP SLAB

REINFORCED PRECAST

CONCRETE EXTENSION

BOX

REINFORCED PRECAST

CONCRETE BOX SLAB

NOTE:

PROVIDE HAND HOLE WITH ACCESSORIES IN ACCORDANCE WITH DEPARTMENT OF THE

ARMY I3A, 2017, SECTION 3.7.2 HAND HOLES. ACCEPTABLE SIZE SHALL BE 4 FEET X 4 FEET

X 4 FEET IN SIZE.

(M

IN

23.5" (MIN.)

6 1/2" 6"6"

WARNING TAPE

4" PVC CONDUITS W/

(6) CELL INNERDUCT

COMPACTED

BACKFILL

(M

IN

23.5" (MIN.)

6"

WARNING TAPE

3" PVC CONDUITS W/

(3) CELL INNERDUCT

COMPACTED

BACKFILL

6"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

N E

W D

A

IR

Y F

O R

A G

E R

E S

E A

R C

H C

E N

T E

R

A u to d e s k D o c s

/1 U

S D

A D

F R

C /4

-T

-A L L -C e n tr a l.

rv t

/4

/2

:2

:3

P

M

T-501

T E

L E

C O

M M

U N

IC

A

T

IO

N S

D E

T A

IL

S

P R

A

IR

IE

D

U S

A C

W

I O

M A

H A

D

IS

T R

IC

T

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

J .F

A L L O

N

J .H

E S

S L E

R

D .R

O B

E R

T S

/0

/2

W F

C

W F

C

NOT TO SCALEH1

BONDING AND GROUNDING CONDUCTOR

NOT TO SCALEA1

FIRE STOPPING SYSTEM NO. C-AJ-009/UL-318

NOT TO SCALEA9

CABLE PENETRATION DETAIL

NOT TO SCALEA16

TYPICAL HAND HOLE

NOT TO SCALEL9

DUCT-BANK DETAIL - 1 X 2

NOT TO SCALEL15

DUCT-BANK DETAIL - 1 X 1

R T

A

/0

/2

VERTICAL RUNWAY

SPLICE KIT

CABLE RUNWAY

RUNWAY BEND/

SWIVEL END

SPLICE

CABLE RADIUS DROP TO

MAINTAIN PROPER BEND

RADIUS OF CABLES

RUNWAY SIDE

MOUNTING

JUNCTION KIT

CABLE RADIUS DROP

NOTES:

1. ALL CONNECTION HARDWARE, PARTS AND PIECES ARE TO BE OF

THE SAME MANUFACTURER AS THE CABLE RUNWAY AND

APPROVED BY THE MANUFACTURER AS APPROPRIATE FOR THE

APPLICATION.

#6 AWG GROUNDING

BONDING WIRE

#6 AWG GROUNDING

BONDING WIRE

#6 AWG GROUNDING

BONDING WIRE

RUNWAY STRINGER

TRIANGULAR RUNWAY

WALL MOUNT SUPPORT

ITEM QTY. DESCRIPTION

1 1 GROUND BAR

2 2 WALL MOUNTING BRACKET

3 2 INSULATOR

4 4 5/8-11 x 1" HHCS

5 4 LOCK WASHER

(2) CAT6-A CABLES

TO NEAREST

TELECOM CABINET

OR TELECOM ROOM

UNISTRUT

CAT6-A PATCH CORD

2-PORT PLENUM RATED

SURFACE MOUNT BOX

W/ CAT6-A OUTLETS

FRONT VIEW

CABLE BRACKET

RUNWAY SPLICE

END CAD

INSULATED

COPPER

EQUIPMENT

GROUND

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

N E

W D

A

IR

Y F

O R

A G

E R

E S

E A

R C

H C

E N

T E

R

A u to d e s k D o c s

/1 U

S D

A D

F R

C /4

-T

-A L L -C e n tr a l.

rv t

/4

/2

:2

:4

P

M

T-502

T E

L E

C O

M M

U N

IC

A

T

IO

N S

D E

T A

IL

S

P R

A

IR

IE

D

U S

A C

W

I O

M A

H A

D

IS

T R

IC

T

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

J .F

A L L O

N

J .H

E S

S L E

R

D .R

O B

E R

T S

/0

/2

W F

C

W F

C

NOT TO SCALEK1

TYPICAL RUNWAY CONNECTIONS DETAIL

NOT TO SCALEA1

CABLETRAY-RUNWAY WALL SUPPORT KIT

NOT TO SCALEA10

TELECOMMUNICATIONS PRIMARY BONDING BAR (PBB)

NOT TO SCALEK10

WIRELESS ACCESS POINT W/MOUNTING BRACKET TO UNISTRUT SUPPORT

NOT TO SCALEE1

CABLETRAY-CABLE BRACKET GROUND SUPPORT

R T

A

/0

/2

MESH TYPE

CABLE TRAY

BRACKET WITH

5" RADIUS

MESH TYPE

CABLE TRAY

BRACKET WITH

5" RADIUS

MESH TYPE CABLE

TRAY

U-BOLT

BRACKET

(3) 4" CONDUITS UON.

CONDUIT

GROUNDING LUG

GROUNDING WIRE

MESH TYPE

CABLE TRAY

USE HOOK AND LOOP STRIPS

TO

SECURE CABLES TO RUNWAY

VERTICAL WALL BRACKET

RUNWAY FOOT KIT

BONDING BUSHING

FLOOR SLAB

EQUIPMENT BONDING

CABLE

CONNECTOR

CONDUIT SLEEVES OR

CONDUITS THRU FLOOR SLAB.

NUMBER OF CONDUIT PER

SHEET PLAN

TELECOMMUNICATIONS CABLES

PER SHEET PLAN

CABLE RUNWAY

1 1/2" METAL FRAMING

CHANNEL ANCHORED

TO WALL 4/-0" O.C.

WALL

SECURELY ANCHOR

RUNWAY FOOT TO FLOOR

NOTES:

1. FIRE STOP ALL PENETRATIONS PER

SPECIFICATIONS.

2. CABLE RUNWAY TO BE INSTALLED FROM FLOOR

TO CEILING.

BRACKET

TWO POST RACK

CABLE RUNWAY

ASSEMBLY HARDWARE

#6AWG GROUNDING BONDING WIRE

RELAY RACK

ISOLATION PAD

11/16" HOLE

12 1/2"

15"

16"

20 5/16"

NOTE:

MOUNT RACK ON TOP OF ANTI-STATIC FLOOR TILE

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

N E

W D

A

IR

Y F

O R

A G

E R

E S

E A

R C

H C

E N

T E

R

A u to d e s k D o c s

/1 U

S D

A D

F R

C /4

-T

-A L L -C e n tr a l.

rv t

/4

/2

:2

:5

P

M

T-503

T E

L E

C O

M M

U N

IC

A

T

IO

N S

D E

T A

IL

S

P R

A

IR

IE

D

U S

A C

W

I O

M A

H A

D

IS

T R

IC

T

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

J .F

A L L O

N

J .H

E S

S L E

R

D .R

O B

E R

T S

/0

/2

W F

C

W F

C

NOT TO SCALEE1

CABLE TRAY - 90 DEGREE SWEEP DETAIL

NOT TO SCALEA1

CABLE TRAY - "T" DETAIL

NOT TO SCALEJ1

CABLE TRAY - CONDUIT ATTACHMENT

NOT TO SCALEA8

CABLE - VERTICAL RUNWAY MOUNTING

NOT TO SCALEJ15

CABLE RUNWAY STAND-OFF KIT

NOT TO SCALEJ8

SELF SUPPORTED EQUIPMENT RACK ISOLATION KIT

R T

A

/0

/2

OUTLET NAMEPLATE LABEL

SINGLE GANG STAINLESS

STEEL FACEPLATE

SINGLE GANG BOX

1" CONDUIT TO ACCESSIBLE CEILING

TELEPHONE MOUNTING PIN

(1) CAT6-A - 4 PR CABLE

(1) SINGLE CAT6-A

JACK, 8-POSITION

NOTE:

WATERPROOF OUTLETS UTILIZED.

WALL MOUNTED WITH COVER LID.

WALL

OUTLET NAMEPLATE LABEL

MUD/PLASTER RING

(DEVICE COVER)

SINGLE GANG STAINLESS

STEEL FACEPLATE W/

TELEPHONE MOUNTING PINS

SINGLE GANG BOX

1" CONDUIT TO ACCESSIBLE CEILING

TELEPHONE MOUNTING PIN

(1) CAT6-A - 4 PR CABLE

(1) SINGLE CAT6-A

JACK, 8-POSITION

W

OUTLET NAMEPLATE LABEL

MUD/PLASTER RING

(DEVICE COVER)

SINGLE GANG STAINLESS

STEEL FACEPLATE W/

TELEPHONE MOUNTING PINS

SINGLE GANG BOX

1" CONDUIT TO ACCESSIBLE CEILING

TELEPHONE MOUNTING PIN

(1) CAT6-A - 4 PR CABLE

(1) SINGLE CAT6-A

JACK, 8-POSITION

OUTLET NAMEPLATE LABEL

DOUBLE GANG

MUD/PLASTER RING

(DEVICE COVER)

DOUBLE GANG (STANLESS

STEEL 4-POSITION

FACEPLATE)

DOUBLE GANG BOX

1 1/2" CONDUIT TO

ACCESSIBLE CEILING/

CABLE TRAY

(4) CAT6-A - 4 PR CABLE

(4) RJ45-8-POSITION TELE / DATA

INSERT CAT6-A

NOTE:

TERMINATE - TIA-568B

CONFIGURATION.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

N E

W D

A

IR

Y F

O R

A G

E R

E S

E A

R C

H C

E N

T E

R

A u to d e s k D o c s

/1 U

S D

A D

F R

C /4

-T

-A L L -C e n tr a l.

rv t

/4

/2

:2

:5

P

M

T-504

T E

L E

C O

M M

U N

IC

A

T

IO

N S

D E

T A

IL

S

P R

A

IR

IE

D

U S

A C

W

I O

M A

H A

D

IS

T R

IC

T

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

J .F

A L L O

N

J .H

E S

S L E

R

D .R

O B

E R

T S

/0

/2

W F

C

W F

C

NOT TO SCALEB2

WATERPROOF BOX OUTLET-DATA

NOT TO SCALEK2

WALL OUTLET - WALL PHONE

NOT TO SCALEB8

WALL OUTLET - DATA

NOT TO SCALEK8

WALL OUTLET - TELE/DATA W/ DOUBLE BOX - 4 PORT

R T

A

/0

/2

FLOOR

M O

U N

T C

A B

L E

T R

A Y

A

.F .F

4RU-RESERVED FOR

SERVICE PROVIDER

RACK GROUNDING

8 10

RESERVED RACK FOR

SWITCH GEAR

PROVIDED BY GFGI

KEY NOTES:

1. 1RU-HORIZONTAL WIRE MANAGER

(TYPICAL).

2. 1RU- FIBER LC PATCH PANEL FOR OUT

BUILDING FIBER DISTRIBUTION.

3. 2RU-48 PORT CAT6-A PATCH PANEL, W/

CAT6-A RJ45 INSERTS FOR WAPS.

4. 3-INCH VERTICAL WIRE MANAGEMENT,

BOTH SIDES OF RACK (TYPICAL).

5. 45RU -19-INCH 2-POST OPEN RACK

(TYPICAL).

6. HORIZONTAL POWER STRIP PROVIDE BY

GFGI .

7. 3/4 INCH FIRE RATED PLYWOOD.

8. TELECOMMUNICATION GROUNDING BAR

PROVIDED BY DIVISION 26.

9. RACK GROUNDING STRIP KIT, PROVIDE ONE

PER RACK (TYPICAL) NOTE: EQUIPMENT

JUMPERS PROVIDED BY OTHERS.

10. #6 GROUND CABLE FROM TELECOM

GROUND BAR TO EACH CABINET.

11. 18 INCH LADDER TRAY.

12. SECURITY 4 POST RACK BY DIVISION 28.

(POWER PROVIDED BY DIVISION 26)

STRUCTURAL BEAM.

6" NEMA-4 CABLE TROUGHS

TO RECEIVE CONDUITS

AND CABLE

FINISHED FLOOR

32"H X 24"W X 18"D NEMA

4 RATED CABINET, W/

16RU-19"RACK. (TYP)

CLIMATE CONTROL

115VAC EXHAUST FAN

AND 100W-1000W 115 VAC

HEATER.

OSP CABLES U-GUARD,

GALVANIZED STEEL

PROTECTION.

ENTRY CONDUITS FOR

SECURITY, TELECOM

AND ELECTRICAL

CABLES. (TYP)

1RU-12-PORT FIBER

PATCH PANEL.

POE SWITCH PROVIDED

BY GFGI.

2RU - CAT6-A PATCH

PANEL. (TYP)

20AMP,115V DEDICATED

GUAD RECEPTACLE

PROVIDED BY DIV. 26.

1RU HORIZONTAL

COPPER GROUND BAR,

W/ #6 AWG GRN. CABLE

TERMINATED TO

STRUCTURE BEAM

PROVIDED BY DIV. 27.

1RU-HORIZONTAL WIRE

MANAGER. (TYP)

MOUNT CABINET AND

CONDUITS TO BEAM W/

GALVANIZED UNISTRUT.

(TYP)

TC

1" RIGID CONDUIT TO

NETWORK SWITCH

TWO PORT RJ45 CAT

6A OUTLET

NEMA 3 ENCLOSURE

10" x 10" x 6"

1. 5" RIGID CONDUIT

(2) CAT6A PATCH

CABLES

WIRELESS ACCESS

POINT

SUPPORT MOUNTING

CABLE

NOTE:

DETAIL INDICATES DESIGN INTENT ONLY. FINAL

MOUNTING OF WAP AND SUSPENSION FROM

STRUCTURE SHALL COMPLY W/ MANUFACTURES

INSTALLATION REQUIREMENTS AND APPLICABLE

CODES GFGI.

TELECOM CABINET

DOOR

LOCK

BACKPAN 16-GAUGE

STEEL WITH 12 1/2" X12 1/2"

CUTOUT IN CENTER FOR

ELECTRICAL PULL-BOX

1/2", 2" AND 3"

ELECTRICAL

KNOCKOUT

ON THE TOP

AND BOTTOM,

FOR

SECURITY,

TELECOM

AND

ELECTRICAL

INCOMING

CONDUITS.

SWING OPEN

CENTER SECTION

CLEARANCE

LOCK

RACKRAIL KIT

FRONT AND BACK

D-RING

36"H x 24"W x 24"D

WALL MOUNTED

NEMA 4 RATED

CABINET WITH 12

RACK UNIT SPACE

TOP VIEW

SWING OPEN

CENTER

SECTION

5"

20"

SWING OPEN

CENTER

SECTION

NOTES:

1. PROVIDE ALL THE NECESSARY HARDWARE, PARTS FOR CABLE MANAGEMENT

FEATURE INCLUDING CABLE PASS-THROUGH ON BACKPAN, ABUNDANT CABLE

TIE POINTS, INTEGRAL LACING BAR.

2. PROVIDING BONDING FOR WALL RACK PARTS, CENTER SECTION AND DOOR.

FINISHED FLOOR

TC

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

N E

W D

A

IR

Y F

O R

A G

E R

E S

E A

R C

H C

E N

T E

R

A u to d e s k D o c s

/1 U

S D

A D

F R

C /4

-T

-A L L -C e n tr a l.

rv t

/4

/2

:2

:0

P

M

T-505

T E

L E

C O

M M

U N

IC

A

T

IO

N S

D E

T A

IL

S

P R

A

IR

IE

D

U S

A C

W

I O

M A

H A

D

IS

T R

IC

T

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

J .F

A L L O

N

J .H

E S

S L E

R

D .R

O B

E R

T S

/0

/2

W F

C

W F

C

NOT TO SCALEJ2

TELECOMMUNICATIONS RACK ELEVATION BUILDING A

NOT TO SCALEA2

TELECOM AND SECURITY COLUMN MOUNTED CABINET (TYP)

NOT TO SCALEK12

OUTSIDE WIRELESS ACCESS POINT SUSPENDED TRUSS MOUNT (TYP)

NOT TO SCALEA13

TELECOM CABINET - WALL MOUNT EQUIPMENT (TYP)

R T

A

/0

/2

1. (1) 12-STRAND SM FIBER OPTIC CABLES,

OSP RATED.

2. (1) DEDICATE LAST TWO STRANDS

OF 12 STRAND NETWORK FIBER TO

BUILDING A FOR FIRE PROTECTION.

3. (1) 4 STRAND SINGLE MODE FIBER DROP

OSP RATED TERMINATED WITH LC

CONNECTORS ROUTED FROM FIRE

PANEL TO B11-TC FIBER PANEL.

KEYNOTES:

BUILDING A TER

NOTE:

BUILDING CONTRACTOR TO COORDINATE

INCOMING OSP CONDUIT AND FIBER WITH

SERVICE PROVIDER.

BUILDING B8 TC

BUILDING B7 TC

BUILDING B11 TC

BUILDING B9 TC

BUILDING C2 TC

BUILDING B3.1 TC

BUILDING B3.2 TC

BUILDING B4 TC

BUILDING B5 TC

BUILDING B6.1 TC

BUILDING B6.2 TC

BUILDING A2

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

N E

W D

A

IR

Y F

O R

A G

E R

E S

E A

R C

H C

E N

T E

R

A u to d e s k D o c s

/1 U

S D

A D

F R

C /4

-T

-A L L -C e n tr a l.

rv t

/4

/2

:2

:1

P

M

T-601

T E

L E

C O

M M

U N

IC

A

T

IO

N S

R

IS

E R

S D

IA

G

R A

M

P R

A

IR

IE

D

U S

A C

W

I O

M A

H A

D

IS

T R

IC

T

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

J .F

A L L O

N

J .H

E S

S L E

R

D .R

O B

E R

T S

/0

/2

W F

C

W F

C

NOT TO SCALED4

TELECOMMUNICATIONS FIBER RISER DIAGRAM

R T

A

/0

/2

1. CONDUIT SIZES INDICATED ON DRAWINGS ARE MINIMUM ACCEPTABLE. ALL NEW

CONDUITS SHALL BE SIZED TO PROVIDE SPARE CAPACITY IN ACCORDANCE WITH

THE NEC.

2. FIELD VERIFY EXISTING CONDITIONS PRIOR TO BIDDING AND INSTALLATION.

3. THE DRAWINGS ARE DIAGRAMMATIC AND REFLECT DESIGN INTENT ONLY. ALL

UNDERGROUND CONDUITS, SLEEVES, FEEDS TO EQUIPMENT INSTALLATION AND

PLACEMENT OF THAT EQUIPMENT SHALL BE VERIFIED IN FIELD AND WITH OTHER

TRADES PRIOR TO INSTALLATION. SECURITY CONTRACTOR SHALL VISIT SITE

PRIOR TO SUBMITTING BID AND NOTE ALL APPARENT FEATURES WHICH MAY

AFFECT THE WORK OF THIS CONTRACT. NO SUBSEQUENT ALLOWANCES WILL BE

MADE FOR FAILURE TO VISIT SITE PRIOR TO BID OR FOR LACK OF FIELD

COORDINATION WITH THE WORK OF THE OTHER TRADES.

4. COORDINATE ELECTRICAL ROUGH-IN REQUIREMENTS WITH THE ELECTRICAL

CONTRACTOR/TRADES AT ALL LOCATIONS OF ALL ELECTRICAL POWERED

EQUIPMENT.

5. WHERE ROUTING OF RACEWAY/CONDUIT IS SHOWN ON PLANS TO PASS

THROUGH WALLS AND PARTITIONS, CORE DRILL PENETRATIONS UNLESS

SPECIFICALLY NOTED OTHERWISE. SIMILAR CUTTING AND PATCHING TO MATCH

EXISTING SURFACES MAY BE UTILIZED WHERE CONDITIONS PERMIT.

6. ALL FLOOR AND WALL CONDUIT PENETRATIONS SHALL BE SLEEVED AND SEALED

WITH AN INTUMESCENT FIRE RESISTIVE SYSTEM IN ACCORDANCE WITH N.E.C.,

N.F.P.A. AND DIVISION 07 OF THE SPECIFICATIONS.

7. ALL INTERIOR CONDUITS SHALL BE A MINIMUM OF 3/4" AND EXTERIOR CONDUIT

SHALL BE A MINIMUM OF 1" UNLESS OTHERWISE NOTED. CONDUIT SIZES

INDICATED SHALL BE THE MINIMUM SIZES UTILIZED.

8. ALL CONDUIT AND WIRING SHALL BE CONCEALED UNLESS OTHERWISE NOTED

ON THE DRAWINGS AND/OR LOCATED IN ELECTRICAL, MECHANICAL OR STORAGE

ROOMS OR SIMILAR UNFINISHED SPACES.

9. VERIFY THE LOCATIONS OF PARTITIONS AND AVOID CONFLICTS WITH LIGHTS,

DIFFUSERS, GRILLES, DUCTWORK, AND OTHER OBSTRUCTIONS.

10. CONDUIT RUNS INDICATED REFLECT DESIGN INTENT ONLY. ALL PULL BOXES AND

JUNCTION BOXES SHALL BE SIZED IN ACCORDANCE WITH THE N.E.C. VERIFY

QUANTITY AND LOCATION OF PULL BOXES AND JUNCTION BOXES IN

ACCORDANCE WITH CABLE MANUFACTURERS RECOMMENDATIONS.

11. CONTRACTOR SHALL HAVE THE OPTION TO COMBINE HOMERUN CONDUCTORS

OF REMOTE DEVICES OF SAME TYPE AND VOLTAGE CLASS AS PER THE N.E.C.

SIZE CONDUIT AND INSTALL CONDUCTORS IN ACCORDANCE WITH THE N.E.C.,

N.F.P.A. AND DIVISION 26 OF THE SPECIFICATIONS.

12. COORDINATE EXACT LOCATION(S) OF CEILING MOUNTED EQUIPMENT/DEVICES

WITH ARCHITECTURAL PLANS, REFLECTED CEILING PLANS, STRUCTURAL PLANS,

AND ALL…

This is the start of the file's text. The full file is on GovTribe.