These are architectural telecommunications and security floor plan drawings for the new Dairy Forage Research Center (DFRC) located in Prairie du Sac, Wisconsin. The documents are part of the solicitation for construction services, prepared by the US Army Corps of Engineers Omaha District. The floor plans detail the telecommunications and security infrastructure for Area A of the Lab and Admin building, showing detailed room layouts, equipment placement, and key technical specifications. The drawings include specific technical notes about routing conduits, placing network equipment, and coordinating security and telecommunications systems, with key elements like wall-mounted wireless access points, fiber optic terminations, and security camera locations precisely mapped across the facility's floor plan.
The drawings are part of a larger project to construct an approximately 254,003 square foot research facility supporting USDA-ARS dairy research capabilities, with the design accommodating up to 452 lactating cows, 144 calves, and supporting research staff. The documents are marked with Addendum #17 and dated 06/10/2025, with the solicitation number W9128F20C0053 and contract number W9128F21C0023, indicating an ongoing procurement process for this comprehensive research center construction project.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SIGNAGE PLAN GENERAL NOTES
1. DO NOT SCALE DRAWINGS.
2. MESSAGE TEXT FOR ALL SIGN TYPES SHALL BE
COORDINATED WITH THE CLIENT PRIOR TO FABRICATION.
3. MESSAGE SCHEDULE (APPENDIX 10 14 00.20a), LOCATION
PLANS (SERIES AG), AND DRAWING SHEETS (SERIES AG) TO
BE COORDINATED FOR COMPLETE INFORMATION.
4. MESSAGE SCHEDULE (APPENDIX 10 14 00.20a), LOCATION
PLANS (SERIES AG), AND DRAWING SHEETS (SERIES AG) TO
BE CONFIRMED TO AS-BUILT CONDITIONS PRIOR TO
PRODUCTION.
5. REFER TO SPECIFICATIONS FOR COMPLETE MESSAGE
SCHEDULE (APPENDIX 10 14 00.20a).
SIGNAGE PLAN LEGEND
WAYFINDING SIGN#### - XXXX
ROOM/REGULATORY SIGN#### - XXXX
LIFE SAFETY SIGN#### - XXXX
WORK STATION ID #### - XXXX
B1-101.6 - ST12B1-101.5 - ST12 B1-101.6 - ST12
B1-106.2 - RGM
B1-101.2 - RID
B1-101.4 - EXIT
B1-101.3 - IPM
B1-103 - RID B1-104 - RID
B1-107A - RID B1-107C - RID
B1-107B - RID B1-107D - RID
B1-105.1 - RID
B1-105.2 - ST8
B1-105.3 - IPM
B1-106.1 - RID
B1-108 - RID
B1-100-ST8
B1-102-ST8
B1-101.1 - FEC
B1-106.3 - FEC
B1-101.4 - FEC B1-101.7 - FEC
A38.1 - DOM
A38.2 - DOM
M E
TA
B
O
LI
C
A D
D E
N D
U M
A
D D
E N
D U
M
/1
3/
/1 /2
CHAMBERS
METABOLIC
METABOLIC
CHAMBER
METABOLIC
METABOLIC
CHAMBER
B1 - 107A
METABOLIC
CHAMBER
B1 - 107B
METABOLIC
CHAMBER
B1 - 107C
METABOLIC
CHAMBER
B1 - 107D
/2
J J J
J
J
J
T-201-A
K1
WP
WP
WP
A.A A.B
A.C A.D A.E A.F A.G A.H A.I A.J A.KA.B2
A.5
A.4
A.3
A.J.8
A.2
A.1
BOILER ROOM
A43
SEMINAR ROOM
A02
TOILET FEMALE
A04
OVERNIGHT /
NURSING
MOTHER
A05
TOILET MALE
A03
STOR. TABLE /
CHAIR
A17
DISPLAY AREA
A01
WASHER/ DRYER
A36
BREAK
A20
SHOWER MALE
A21
SHOWER FEMALE
A22
MUD ROOM
A24
CORRIDOR
A38
OFFICE
A08
OFFICE
A07
GLASSWARE
WASH
A26
CYLINDER
A29
WALK-IN
FREEZER
A30
INCUB. ROOM
A31
FERMENTATION
ROOM
A32
LABORATORY
LARGE
A34
LABORATORY
LARGE
A33
SAMPLE
STORAGE ROOM
A28
CHEM
A27
CORRIDOR
A40
OFFICE
A09
OFFICE
A10
OFFICE
A11
OFFICE
A12
TELECOM
A16
GARBAGE
A25
CORRIDOR
A39
STOR. ELEC.
A18
ELEC
A19
STOR.
A35
JC
A23
ELEC
A41
ELEC
A42
VESTIBULE
A01B
CHILLER ROOM
A44
MECHANICAL
A37
BCS
A15
COMPUTER
ROOM
A14
PRINT/COPY
A13
"x
8"x4"
"x
EZ-PATH
+54"
+54"
+50"
+48"
+48"
+48"
+48"
+48"
A.6
A.D2
A.D2
8"x4"
"x
6"x4"
"x
6"x4"
EZ-PATH
EZ-PATH EZ-PATH EZ-PATH EZ-PATH EZ-PATH
FACP
B1.1 B2.1
+48"
+48"
+48"
+48"
+48"
+48"
EZ-PATH
EZ-PATH
EZ-PATH
EZ-PATH
+48"+48" +48"
+48"
+48"
+48"
+48" +48"
6"x4"
6"x4"
"x
6"x4"
6"x4"
EZ-PATH
EZ-PATH
EZ-PATH
1. 3" EMT ROUTED FROM CABLE TRAY TO
16"X16"X 8" CEILING ACCESS PULL BOX.
ROUTE WORKSTATION CONDUITS FROM
SEMINAR ROOM TO PULL BOX IN THE
CEILING OF THE TOILET ROOM.
2. WALL MOUNTED WAP.
3. (1) 4-STRAND SINGLE MODE RATED
FIBER TERMINATION WITH LC
CONNECTORS INSIDE FIRE PANEL AND
ON PATCH PANEL INSIDE TELECOM
ROOM A16.
NOTE: DIVISION 27 CONTRACTOR TO
COORDINATE WITH FIRE PROTECTION
CONTRACTOR ON INSTALLATION OF
FIBER TO FIRE PANEL.
KEY NOTES:
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
N E
W D
A
IR
Y F
O R
A G
E R
E S
E A
R C
H C
E N
T E
R
A u to d e s k D o c s
/1 U
S D
A D
F R
C /4
-T
-A L L -C e n tr a l.
rv t
/1
/2
:5
:0
P
M
T-101-A
T E
L E
C O
M M
U N
IC
A
T
IO
N S
F L O
O R
P L A
N
A R
E A
A
L A
B
A D
M
IN
P R
A
IR
IE
D
U S
A C
W
I O
M A
H A
D
IS
T R
IC
T
H D
R A
R L
IN
G T
O N
V
IR
G
IN
IA
J .F
A L L O
N
J .H
E S
S L E
R
D .R
O B
E R
T S
/0
/2
W F
C
W F
C
3/32" = 1'-0"A1
TELECOMMUNICATIONS FLOOR PLAN - AREA A - LAB & ADMIN
NORTH
KEY PLAN
A
16'8' 32'0
R T
A
/0
/2
A
D D
E N
D U
M
/1 /2
R
R
R
R
RG
G
G G
G G
G
S E
C
G G G G G G G G G
G
G
G
KP
R
R
R
A16
A24A
A A
A.A A.B
A.C A.D A.E A.F A.G A.H A.I A.J A.KA.B2
A.5
A.4
A.3
A.J.8
A.2
A.1
BOILER ROOM
A43
SEMINAR ROOM
A02
TOILET FEMALE
A04
OVERNIGHT /
NURSING
MOTHER
A05
TOILET MALE
A03
STOR. TABLE /
CHAIR
A17
DISPLAY AREA
A01
WASHER/ DRYER
A36
BREAK
A20
SHOWER MALE
A21
SHOWER FEMALE
A22
MUD ROOM
A24
CORRIDOR
A38
OFFICE
A08
OFFICE
A07
GLASSWARE
WASH
A26
CYLINDER
A29
WALK-IN
FREEZER
A30
INCUB. ROOM
A31
FERMENTATION
ROOM
A32
LABORATORY
LARGE
A34
LABORATORY
LARGE
A33
SAMPLE
STORAGE ROOM
A28
CHEM
A27
CORRIDOR
A40
OFFICE
A09
OFFICE
A10
OFFICE
A11
OFFICE
A12
TELECOM
A16
GARBAGE
A25
CORRIDOR
A39
STOR. ELEC.
A18
ELEC
A19
STOR.
A35
JC
A23
ELEC
A41
ELEC
A42
VESTIBULE
A01B
CHILLER ROOM
A44
MECHANICAL
A37
BCS
A15
COMPUTER
ROOM
A14
PRINT/COPY
A13
A B
A.D2
ELECTRICAL
PANEL
A40A
A01B
VMS
VSS
BDG
A1
TY-502
A10
TY-502
(TYP)
(TYP)
CA-01-CD
CA-04-D
CA-04-D
CA-02-B
A B
LOCATED ON PEDESTAL
BELOW ABA/ADA
PUSHBUTTON
CA-21-CD
A43
A A
CA-21-CD
A10
TY-502
(TYP)
A10
TY-502
(TYP)
A10
TY-502
(TYP)
A. REFER TO DRAWING TY-001 FOR
SECURITY LEGENDS, GENERAL NOTES
AND ABBREVIATIONS.
B. HOMERUN ALL SECURITY EQUIPMENT TO
TELECOM CABINET ON THIS DRAWING.
GENERAL NOTES:
1. SECURITY EQUIPMENT CABINET. SEE
TELECOM SHEETS T-201-A/K1 & T-505/J2.
KEY NOTES:
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
N E
W D
A
IR
Y F
O R
A G
E R
E S
E A
R C
H C
E N
T E
R
A u to d e s k D o c s
/1 U
S D
A D
F R
C /4
-T
-A L L -C e n tr a l.
rv t
/1
/2
:5
:1
P
M
TY-101-A
S E
C U
R
IT
Y F
L O
O R
P L A
N
A R
E A
A
L A
B
A D
M
IN
P R
A
IR
IE
D
U S
A C
W
I O
M A
H A
D
IS
T R
IC
T
H D
R A
R L
IN
G T
O N
V
IR
G
IN
IA
W .O
N D
E R
IC
K
J .H
E S
S L E
R
D .R
O B
E R
T S
/0
/2
W F
C
W F
C
NORTH
KEY PLAN
A
3/32" = 1'-0"A1
SECURITY FLOOR PLAN - AREA A - LAB & ADMIN
16'8' 32'0
R T
A
/0
/2
A
D D
E N
D U
M
/1 /2
| AG-101-B1 - WAYFINDING PLAN - AREA B1 - METABOLIC CHAMBERS |
| T-101-A - TELECOMMUNICATIONS FLOOR PLAN - AREA A - LAB & ADMIN |
| 483980-T-ALL-Central |
| T-101-A - TELECOMMUNICATIONS FLOOR PLAN - AREA A - LAB & ADMIN |
| TY-101-A - SECURITY FLOOR PLAN - AREA A - LAB & ADMIN |
| 483980-T-ALL-Central |
| TY-101-A - SECURITY FLOOR PLAN - AREA A - LAB & ADMIN |
File details come from the government source that posted it. Updated .