Amendment 07 - Ad_0003_Drawings_04.01.2025.pdf

PDF 840 KB Posted

Attached to
CANCELED - USDA Dairy Forage Research Center (DFRC)
Solicitation number
W9128F25R0014
Issued by

About this file

This document is a detailed architectural drawing set for the USDA Dairy Forage Research Center (DFRC) in Prairie du Sac, Wisconsin, specifically showing electrical and laboratory floor plan details. The drawings include a first-floor enlarged laboratory floor plan (Sheet Q-401-A), a laboratory controlled temperature room schedule and details (Sheet Q-503-A), and electrical site plan and one-line diagrams (Sheets ES-101 and ES-103). Key technical details include specifications for a controlled temperature room (CTR-1) with dimensions of 10'10" x 20'11" x 9'4", operating at -6°C ±1°C, powered by a 208V/3-phase electrical system, and requiring emergency power. The electrical site plan depicts complex utility infrastructure, including multiple transformers, underground and overhead service conductors, and power distribution for various buildings within the research center complex.

View the file

Other files

File Type Posted
W9128F25R0014 Amendment 16 - 09.09.2025.pdf PDF
W9128F25R0014 Amendment 15 - 07.22.2025.pdf PDF
W9128F25R0014 Conformed thru Amd 14 - 07.11.2025.pdf PDF
W9128F25R0014 Amendment 14 - 07.11.2025.pdf PDF
Am_0013_Specs_ARS01.pdf PDF
W9128F25R0014 Amendment 13 - 07.10.2025.pdf PDF
Am_0012_Dwgs_ARS01.pdf PDF
W9128F25R0014 Conformed thru Amd 11 - 06.06.2025.pdf PDF
W9128F25R0014 Amendment 11 - 06.06.2025.pdf PDF
Am_0011_Dwgs.pdf PDF
W9128F25R0014 Conformed thru Amd 10 - 05.30.2025.pdf PDF
W9128F25R0014 Amendment 10 - 05.30.2025.pdf PDF
W9128F25R0014 Conformed thru Amd 09 - 05.23.2025.pdf PDF
Am_0009_Dwgs_ARS01.pdf PDF
W9128F25R0014 Conformed thru Amd 09 - 05.23.2025.pdf PDF
Am_0008_Dwgs_ARS01.pdf PDF
W9128F25R0014 Amendment 08 - 05.16.2025.pdf PDF
W9128F25R0014_Conformed Amd 07 - 04.01.2025.pdf PDF
Amendment 07 - Ad_0008_Drawings_04.01.2025.pdf PDF
W9128F25R0014_CONFORMED THROUGH Amd 07 - 04.01.2025.pdf PDF
W9128F25R0014 Amendment 07 - 04.01.2025.pdf PDF
Amendment 07 - Ad_0011_Drawings_04.01.2025.pdf PDF
Amendment 07 - Ad_0007_Drawings_04.01.2025.pdf PDF
Amendment 07 - Ad_0006_Drawings_04.01.2025.pdf PDF
W9128F25R0014-0006_Dairy Forage_02.14.2025.pdf PDF
Site Visit Sign in Sheet.pdf PDF
W9128F25R0014 - Pre-Award Survey.pdf PDF
Pages from Pages from 20241108_USDA_DFRC_RTA_Dwgs_V1_1_2.pdf PDF
Pages from Pages from 20241108_USDA_DFRC_RTA_Dwgs_V1_4_1 1.pdf PDF
Pages from 20241108_USDA_DFRC_RTA_Dwgs_V1_4_1_2.pdf PDF
Pages from 20241108_USDA_DFRC_RTA_Dwgs_V1_6.pdf PDF
Pages from 20241108_USDA_DFRC_RTA_Dwgs_V1_5.pdf PDF
Pages from Pages from 20241108_USDA_DFRC_RTA_Dwgs_V1_1_1.pdf PDF
Pages from Pages from 20241108_USDA_DFRC_RTA_Dwgs_V1_4_1 7.pdf PDF
Pages from Pages from 20241108_USDA_DFRC_RTA_Dwgs_V1_4_1 4.pdf PDF
Pages from Pages from 20241108_USDA_DFRC_RTA_Dwgs_V1_4_1 8.pdf PDF
Pages from Pages from 20241108_USDA_DFRC_RTA_Dwgs_V1_4_1 2.pdf PDF
Pages from Pages from 20241108_USDA_DFRC_RTA_Dwgs_V1_4_1 9.pdf PDF
Pages from 20241108_USDA_DFRC_RTA_Dwgs_V3_3.pdf PDF
W9128F25R0014 Amd 0003 - 20241210.pdf PDF
20241108_USDA-DRFC_RTA_Specs_V1_00-07 - Updated 9DEC2024.pdf PDF
W9128F25R0014 Amd 0002 - 20241209.pdf PDF
USDA_DFRC_SpecsCvrs_RTA_Vol3.pdf PDF
USDA_DFRC_SpecsCvrs_RTA_Vol1.pdf PDF
Dairy Forage Research Center geotechnical report.rev 06-02-2023.pdf PDF
20241108_USDA-DRFC_RTA_Specs_V2_08-22.pdf PDF
20241108_USDA-DRFC_RTA_Specs_V4_27-43.pdf PDF
W9128F25R0014 Amd 0001 - 20241204.pdf PDF
Solicitation DFRC 22 Nov 2024.pdf PDF
W9128F25R0014_SPECS_ARS01.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GLASSWARE

WASH

A26

CYLINDER

A29

INCUB.

ROOM

A31

FERMENTATION

ROOM

A32

LABORATORY

LARGE

A34

LABORATORY

LARGE

A33

SAMPLE

STORAGE

ROOM

A28

CHEM

A27

GARBAGE

A25

V A

C

C D

A

C F

H

B S

Y B

S

X

B S

S

S K

-1

ST-1ST-1

T S

A T

S

A

S S

-3

B S

F

B S

B B

S

B

B S

F

B S

B

B S

C

B S

F

B S

C B

S F

M B

S B

B M

E

M B

S B

M B

S B

B M

E

M B

S B

M B

S B

B M

E

M B

S B

M B

S B

B M

E

M B

S B

B S

O E

B S

O E

B S

C

B S

B

B S

F

B S

B B

S

B

B S

F

B S

O E

B S

B

ATS60A

M B

S B

B M

E

M B

S B

M B

S B

B M

E

M B

S B

M B

S B

B M

E

M B

S B

B M

E

M B

S B

ATS60A

M B

S B

B M

E

M B

S B

M B

S B

B M

E

M B

S B

M B

S B

B M

E

M B

S B

B M

E

M B

S B

ATS60A

MBS60B MBS60B MBS60B MBS60B

TC30A TC30A

TS30ATS30A

TS30A TS30A

TS30A

TS30A

EWES-1

E W

E S

-1

E W

E S

-1

T S

A

T S

A

CR-C1 CR-C1

TS48A

TC36ATC36A

M B

S B

B M

E

M B

S B

B M

E

M B

S B

B M

E

M B

S B

B M

E

M B

S B

B M

E

M B

S B

B M

E

B M

E

B M

E

M B

S B

M B

S B

ATS60A

EWES-1

T S

A T

S

A

BS42S

SK-1

B S

S

S K

-1

B S

S

S K

-1

B S

C B

S

B B

S

S

S K

-1

M B

S B

B M

E

M B

S B

B M

E

M B

S B

B M

E

M B

S B

B S

C

M B

S B

B M

E

M B

S B

B M

E

M B

S B

B M

E

M B

S B

B M

E

M B

S B

B M

E

M B

S B

B M

E

M B

S B

B M

E

B M

E

B M

E

M B

S B

M B

S B

ATS60A

M B

S B

B M

E

M B

S B

B M

E

M B

S B

B M

E

M B

S B

B M

E

M B

S B

B M

E

M B

S B

B M

E

B M

E

B M

E

M B

S B

M B

S B

ATS60A

T C

B

B S

C

B S

B

B S

B

TS48A TS48A

M B

S B

B M

E

M B

S B

B M

E

M B

S B

B M

E

M B

S B

B M

E

W S

A

W S

A

W S

A

W S

A

W S

A

W S

A

W S

A

B S

S

S K

-1

S S

-1

C F

H

B S

C

C F

H

T E

C X

F L A

M M

C A

B

W S

A

W S

A

W S

A

W S

A

P S

-1

W S

A

W S

A

W S

A

W S

A

W S

A

TC30A TC30A

BS42S

SK-1

B S

S

S K

-1

W S

A

W S

A

V A

C

C D

A

V A

C

C D

A

V

A C

V A

C

C D

A

V

A C

C D

A

V A

C

C D

A

V A

C

C D

A

V

A C

C D

A

CDA -1

VAC -1

VAC -1

CDA -1

V A

C

C D

A

V

A C

C D

A

V A

C

C D

A

V

A C

C D

A

V A

C

C D

A

V

A C

C D

A

VAC -1

CDA -1

VAC -1

CDA -1

V A

C

C D

A

V

A C

C D

A

V

A C

C D

A

B S

O E

B S

F

T S

C

B M

E

B M

E

B M

E

B M

E

B M

E

B M

E

B M

E

B M

E

B M

E

B M

E

B M

E

B M

E

D H

-1

P W

-1

H C

W -1

F -F

R Z

-0

B-REF-001

F -F

R Z

-0

B-FRZ20-001

A D

-F R

Z

-0

E F

-F R

Z -0

B -I

C E

-0

Q-501-A3

Q-501-A

Q-501-A4

Q-501-A6

Q-501-A 7

Q-501-A 5

Q-501-A8

Q-501-A 11

Q-502-A3 4

Q-502-A5 6

Q-502-A7 8

Q-502-A1 2

B S

O E

B S

F

B S

Y B

S

X B

S

B

D R

-1

P W

-1

H C

W -1

D H

-1

DH-1

HCW-1

PW-1

DR-1

AD-FIA-001

AD-CENT-001

AD-SHKR-001

B -U

C E

N T

-0

B -W

S -0

AD-GA-001

F-OV-001

AD-OV-001

AD-OV-001

B -I

N C

-0

D H

-1

H C

W -1

P W

-1

PW-1

HCW-1

DH-1

B S

S

S K

-1

D H

-1

P W

-1

H C

W -1

D H

-1

H C

W -1

P W

-1

P W

-1

H C

W -1

D H

-1

D H

-1

H C

W -1

P W

-1

G W

-1 G

W -1

F X

A

F X

A

F X

A

F X

A

F X

A

F X

A

F X

A

F X

A

CTR-1CTR-1

M B

S B

B M

E

B-REF-001

EF-FRZ-001

EF-REF-001

E F

-G C

-0

EF-FOV-001

EF-FOV-002

EF-MPR-001

EF-AS-001

EF-MPW-001

EF-PR-001

B S

B

MBS60B

TS60B TS60B

C O

C

O

C O

Q-503-A

CP-2

CP-1

CP-1

CP-1

CP-1

CP-1

CP-1

V A

C

C D

A

V A

C

C D

A

C D

A

V A

C

C D

A

V A

C

C D

A

V A

C

C D

A

C O

C O

W S

A

W S

A

BS24B

BS24B

D R

-1

F H

C W

-1

F H

-V A

C -1

F H

-C D

A -1

H C

W -2

P R

-1

H C

W -2

PW-1

WALK-IN

FREEZER

A30 D

R -1

D R

-1

D R

-1

D R

-1

D R

-1

CP-1

CP-1CP-1CP-1

CP-1 CP-1

CP-1

CP-2

CP-1

CP-1CP-1

CP-1CP-1

CP-1

F H

-C D

A -1

F H

C W

-1

F H

-V A

C -1

F H

C W

-1

F H

-V A

C -1

F H

-C D

A -1

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

N E

W D

A

IR

Y F

O R

A G

E R

E S

E A

R C

H C

E N

T E

R

A u to d e s k D o c s

/1 U

S D

A D

F R

C /4

-A

-A R

E A

A -C e n tr a l.

rv t

/2

/2

:5

:3

P

M

Q-401-A

F L O

O R

P L A

N

F

IR

S T

F L O

O R

E

N L A

R G

E D

A

R E

A A

L A

B

A D

M

IN

P R

A

IR

IE

D

U S

A C

W

I O

M A

H A

D

IS

T R

IC

T

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

T D

H Y

IW

M

T C

G

G K

T G

H

Y

/0

/2

W F

C

W F

C

1/4" = 1'-0" A1

ENLARGED LABORATORY FLOOR PLAN

NORTH

KEY PLAN

A

R T

A

/0

/2

A d d e n d u m

I n q u ir y

/2

/2

A d d e n d u m

I n q u ir y

/2

/2

WALL OR COLUMN

WHERE OCCURS

14" x 24"

VIEWING WINDOW

CONTROL PANEL

GROUT AND SEAL ALL

GAPS BETWEEN CER

AND CONC SLAB

2" x 2" METAL TRIM

CLOSURE PANEL

FROM ROOM TO

STRUCTURE

ABOVE OF SAME

MATERIAL AS

EXTERIOR OF

ROOM

STRUCTURAL SLAB ABOVE

Q-503-A

CONTROLLED

ENVIRONMENT

ROOM

CEILING PANEL

WALL OR COLUMN

WHERE OCCURS

CONCRETE FLOOR

INSULATED 4" THICK

FLOOR PANEL

STAINLESS STEEL WING

SHAPE FITTING

CLOSURE PANEL

FROM ROOM TO

STRUCTURE

ABOVE OF SAME

MATERIAL AS

EXTERIOR OF

ROOM

2" BED OF SAND

STUD FRAMING

SEALANT AND

BACKER ROD

TRIM FINISHED TO

MATCH PANELS

INSULATED PANEL

'Z' CLIP

SHEET MEATL SCREEN

/8

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

N E

W D

A

IR

Y F

O R

A G

E R

E S

E A

R C

H C

E N

T E

R

A u to d e s k D o c s

/1 U

S D

A D

F R

C /4

-A

-A R

E A

A -C e n tr a l.

rv t

/2

/2

:0

:0

P

M

Q-503-A

L A

B O

R A

T O

R Y

C T

R S

C H

E D

U L E

D

E T

A

IL

S

A R

E A

A

L A

B

A D

M

IN

P R

A

IR

IE

D

U S

A C

W

I O

M A

H A

D

IS

T R

IC

T

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

T D

H Y

IW

M

T C

G

G K

T G

H

Y

/0

/2

W F

C

W F

C

3/4" = 1'-0"

CONTROLLED TEMPERATURE ROOM ELEVATION

3/4" = 1'-0"

CONTROLLED TEMPERATURE ROOM SECTION

3" = 1'-0"

COLD ROOM - JAMB DETAIL

CONTROLLED TEMPERATURE ROOM SCHEDULE

PROVIDED

BY SPECIFICATION MARK

EXT. DIMENSIONS

Description

MECHANICAL MECHANICAL

MECHANIC

AL

MECHANI

CAL MECHANICAL CONTROL

PANEL

POWER (V/

PHASE/

WIRE/ AMPS)

COND

ENSER

COND

ENSE

R

COND

ENSER

COOLING

METHOD

CONDENSE

R CONDENSER CONDENSER CONDENSER

REMARKSLENGTH WIDTH HEIGHT TEMPERATURE (°C)

TEMPERATURE

RANGE

RELATIVE

HUMIDITY

RELATIVE

HUMIDITY

RANGE

VENTILATION

(CFM/SF)

ELECT

RICAL

ELECT

RICAL

ELECT

RICAL

FLOWRATE

(GPM)

TOTAL HEAT

REJECTION

(MBH)

HP

(NOMINAL)

CONDENSER

LOCATIONVOLTS

PHAS

E AMPS

CFCI 13 21 14 CTR-1 10' - 10" 20' - 11" 9' - 4" Controlled Temperature Room -6°C +/- 1°C 30-50% +/- 0.5% 5-25 208v/3ph/30a 208 3 8.5 Water Cooled 2 11.70 1.5 On Top Of Unit Emergency Power required and condensor equipment located on top of unit

R T

A

/0

/2

A d d e n d u m

I n q u ir y

/2

/2

E1

E2

C1

C1

C2

C3

B10

B14

CO

S

CO

CO

COCO

CO

CO

CO

CO

CO

CO

BS30FBS30ABS30ABS30A

B S A

B S A

B S A

BS30A

B S F

B S A

B S A

B S A

B S A

B S F

B S A

B S A

B S A

B S A

B S A

B S A

B S A

B S A

B S A

B S A

B S A

B S A

BS30ABS30ABS30F*BS30A*BS30A*

B S A

T B C

T B C

PROPOSED LOCATION OF

EMERGENCY GENERATOR

EXISTING 12.47KV

OVERHEAD UTILITY

SERVICE

UE UE UE

UE

UEUEUEUEUEUE

UE

UE

UE

UE

UE

UE

UE

UE

AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE

AE

AE

AE

AE

AE

UE

UE

UE

UE

UE

UE

UE

EXISTING 12.47KV

OVERHEAD UTILITY

SERVICE

EXISTING 12.47KV

OVERHEAD UTILITY

SERVICE

NEW OVERHEAD

SERVICE CONDUCTORSMV-T1-S

2500kVA 12.47kV TO

480/277V PAD MOUNTED

STEP-DOWN

TRANSFORMER

BUILDING B1, B2, &

B3 WILL BE FED

FROM BUILDING A

PROVIDE ONE (1) 45kVA 480V TO 208/120V TRANSFORMER AND ONE (1) 30kVA 480V

TO 208/120V TRANSFORMER

PROVIDE ONE (1) 45kVA

480V TO 208/120V

TRANSFORMER AND ONE

(1) 15kVA 480V TO 208/120V

TRANSFORMER

93.75kVA/75kW 480/277V NATURAL GAS

GENERATOR FOR THE FIRE PUMP

HOUSE, BUILDING B5, B7, B9, & B11

MV-T2-S

400kVA 12.47kV TO

480/277V PAD MOUNTED

STEP-DOWN

TRANSFORMER

UE UE UE

UE

PROVIDE ONE (1) 30kVA 480V TO 208/120V TRANSFORMER AND ONE (1) 30kVA 480V TO

208/120V TRANSFORMER

S3

UE UE UE UE UE UE UE UE

UE

UE

UE

UE UE UEUE UE UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

UE

POWER FOR

AREA C1

UE UE UE UE

BUILDING B6 & B13

WILL BE FED

FROM BUILDING

A1

BUILDING B4 WILL

BE FED FROM

BUILDING A1

BUILDING B8 WILL

BE FED FROM

BUILDING A1

(PROVIDE TWO (2)

45kVA 480V TO

208/120V

TRANSFORMERS)

UE

UE UE UE

UE

UE

UE UE UE

UE

PROVIDE ONE (1) 300kVA 480V TO 208/120V TRANSFORMER AND ONE (1) 45kVA 480V

TO 208/120V TRANSFORMER

PROVIDE ONE (1) 75kVA 480V TO 208/120V TRANSFORMER AND ONE (1) 45kVA 480V

TO 208/120V TRANSFORMER

PROVIDE TWO (2) 45kVA 480V TO 208/120V

TRANSFORMERS

PROVIDE TWO (2) 112.kVA 480V TO

208/120V TRANSFORMERS

ONE (1) SET OF 4-#2 &

#2/0(G) IN A 2-WAY, 4" PVC,

SCHEDULE 40. CONCRETE

ENCASED DUCTBANK

TWO (2) SETS OF 4#350 &

#2/0(G) IN A 4-WAY, 4" PVC,

SCHEDULE 40. CONCRETE

ENCASED DUCTBANK

TWO (2) SETS OF 3-#1/0 &

#3(G) IN A 4-WAY, 4" PVC,

SCHEDULE 40. CONCRETE

ENCASED DUCTBANK

TWO (2) SETS OF 3-#2 &

#4(G) IN A 4-WAY, 4" PVC,

SCHEDULE 40. CONCRETE

ENCASED DUCTBANK

TWO (2) SETS OF 3-#1/0 &

#6(G) IN A 4-WAY, 4" PVC,

SCHEDULE 40. CONCRETE

ENCASED DUCTBANK

MH

MH

MHMH

MH

MH

MH

MH

MH

UE UE UE UE UE UE UE MH

UE

UE

PROVIDE ONE (1) 480V 100A WEATHERPROOF

DISCONNECT SWITCHES FOR THE SUBMERSIBLE

PUMP WITH A CONTROLLER. REFER TO THE CIVIL

PLANS AND ES-103 FOR MORE INFORMATION.

UEUEUEUEUE

UE

UE

UE MH

PROVIDE ONE (1) SET OF 4#4/0 & 1#4 (G) IN

A 2-WAY 4" PVC, SCHEDULE 40. CONCRETE

ENCASED DUCTBANK FOR THE

EMERGENCY AND NORMAL FEEDERS.

UE

UE

UE

UE

UE

UE

UE

UE

UE

MHUE UE UE UE UE UE UE UE UE UE

UE

UE

MH

MHMH

MH

MH

UE

UE

UE

UE UE UE

UE

UE

UE

UE UE

UE

UE UE UE UE UE UE UE UE UE

UE

UE UE UE UE

UE

UE

UE

UE

UEUEUE

UE

UE UE

UE

UE

TYP. THREE (3) SETS OF 3-500MCM &

#2/0(G) IN A 4-WAY, 4" PVC,

SCHEDULE 40. CONCRETE

ENCASED DUCTBANK

MH

UEUEUE

UE

UE

UE

UE

UE

UTILITIES

RESPONSIBILITY

CONTRACTOR'S

RESPONSIBILITY

POWER FOR

AREA C3

UTILITIES

RESPONSIBILITY

CONTRACTOR'S

RESPONSIBILITY

UE UE UE UE UE

POWER FOR

AREA C2

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

N E

W D

A

IR

Y F

O R

A G

E R

E S

E A

R C

H C

E N

T E

R

A u to d e s k D o c s /1

U

S D

A D

F R

C

/4

-E

-A R

E A

A -C e n tr a l.

rv t

/2

/2

:1

:1

A

M

ES-101

E L E

C T

R

IC

A L S

IT

E

P L A

N

P R

A

IR

IE

D

U S

A C

W

I O

M A

H A

D

IS

T R

IC

T

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

R A

Y M

O N

D G

A O

R A

Y M

O N

D G

A O

B E

N J A

M

IN

O M

E D

IC

H

/0

/2

W F

C

W F

C

NORTH

KEY PLAN

A B1

B8

B2

B3

B4 B5 B13

B6 B9

B15

B7

B11

B10

C2

C4

C3 C1

B14

A B1

B8

B2

B3

B4 B5 B13

B6 B9

B15

B7

B11

B10

C2

C4

C3 C1

B14B12.1

B12.2

R T

A

/0

/2

1" = 80'-0"1

ELECTRICAL SITE PLAN

GENERAL NOTES

1. COORDINATE ALL REQUIREMENTS WITH THE UTILITY COMPANY PRIOR TO WORK.

2. ALL UTILITY METERS AT THE TRANSFORMER SHALL COMPLY WITH THE UTILITY STANDARDS.

3. PROVIDE A NEW 100A 480/277V ATS, TWO (2) 480V 3P 60A DISCONNECTS WITH 45 FUSES, TWO (2) 30KVA

TRANSFORMER, AND ONE (1) 100A 208/120V BRANCH PANEL FOR THE FIRE PUMP ROOM.

4. REFER TO THE SINGLE LINE DRAWING E-601-A FOR MORE INFORMATION.

5. FOR THE 75KW GENERATOR, CONTRACTOR TO PROVIDE AN BUS DETAIL WITH TWO (2) 50A, ONE (1) 70A, AND ONE (1) 30A 480V 3PH CIRCUIT BREAKERS TO SERVE THE ANIMAL BUILDINGS. PROVIDE TWO (1) 150A 480V 3PH MAIN BREAKER FOR THE GENERATOR AND THE GENERATOR CAM-LOCK CONNECTION. PROVIDE A TEMPORY

GENERATOR CONNECTION CABINET AND A TEMPORARY GENERATOR CAM-LOCK CONNECTION.

6. FOR BUILDINGS B5, B7, B9, AND B11 EMERGENCY FEEDS, PROVIDE ONE (1) SET OF 4#2 & 1#3(G) IN A 2-WAY, 4"

PVC, SCHEDULE 40. CONCRETE ENCASED DUCTBANK

LEGEND

BID OPTION #4

XOO

PSL CR2

CR3

CR4

PSHH

OOX

MS

CR2

OOX

Aux

CR2

PSH

CR4 CR3

LSLL

CR3

LSL

CR4

OL

LSLL

LSL

Well

Level

Display

HAND – OFF -

AUTO

Pump Run

Command

High

Pressure

Lockout

Pump

Running

Auto Run

Command

Well Low

Level

Level

Transmitter

6.50

L N

DM

UTILITY

TRANSFORMER

MV-T2-S

400 kVA

12.47kV PRI

480/277V SEC.

55/75C

FR3 FILLED

NEW OVERHEAD SERVICE CONDUCTORS.

REFER TO THE DRAWING ES-101 FOR ADDITIONAL INFORMATION.

FIRE

PUMP

HOUSE

PP-1

NEW UNDERGROUND SERVICE CONDUCTORS

REFER TO THE DRAWING ES-101 FOR ADDITIONAL

INFORMATION.

BUILDING

B5

BUILDING

B7

BUILDING

B9

BUILDING

B11

SUBMERSIBLE

PUMP

HOUSE

TYPICAL: REFER TO THE SINGLE LINE

DIAGRAMS IN EACH RESPECTIVE

BUILDING FOR MORE INFORMATION.

45 kVA

480V PRI

208/120V SEC.

FIRE

PUMP

HOUSE

PP-2

NEW EMERGENCY GENERATOR FEEDERS

REFER TO THE DRAWING ES-101 FOR

ADDITIONAL INFORMATION.

FIRE

PUMP

HOUSE

ATS

100/ 100/

100/ 100/

480V 100A

3PH 4P

3#3, 1#8(G)

IN 1-1/4"C

4#2/0, 1#4(G)

IN 2"C

100/ 70/

60/ 50/

600/ 500/

100/ 70/

100/ 100/

45 kVA

480V PRI

208/120V SEC.

30 kVA

480V PRI

208/120V SEC.

300 kVA

480V PRI

208/120V SEC.

45 kVA

480V PRI

208/120V SEC.

4#2/0, 1#4(G)

IN 2"C

4#2/0, 1#4(G)

IN 2"C

4#2, 1#6(G)

IN 1-1/4"C

3 SETS OF

4-500MCM, 1

#2/0G) IN 4"C

3#3, 1#8(G)

IN 1-1/4"C

2 SETS OF

3-300MCM, 1

#2(G) IN

2-1/2"C

3#4, 1#10(G)

IN 1-1/4"C

3#3, 1#8(G)

IN 1-1/4"C

4#2, 1#8(G)

IN 1-1/4"C

4#2, 1#8(G)

IN 1-1/2"C

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

N E

W D

A

IR

Y F

O R

A G

E R

E S

E A

R C

H C

E N

T E

R

A u to d e s k D o c s /1

U

S D

A D

F R

C

/4

-E

-A R

E A

A -C e n tr a l.

rv t

/2

/2

:1

:1

A

M

ES-103

B A

D G

E R

W E

L L

W

E L L P

U M

P D

IA

G

R A

M A

N D

F

IR

E P

U M

P H

O U

S E

S C

H E

D U

L E

S

P R

A

IR

IE

D

U S

A C

W

I O

M A

H A

D

IS

T R

IC

T

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

R A

Y M

O N

D G

A O

R A

Y M

O N

D G

A O

B E

N J A

M

IN

O M

E D

IC

H

/0

/2

W F

C

W F

C

R T

A

/0

/2

12" = 1'-0"1

WELL PUMP CONTROL PANEL DETAIL

NOT TO SCALE2

ELECTRICAL SITE PLAN ONE LINE

DIAGRAM

1. PROVIDE GFPE CIRCUIT BREAKER

Notes:

Total Est. Demand Current: 73 A

Total Conn. Current: 73 A

Total Est. Demand: 61000 VA

Total Conn. Load: 61000 VA

Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Total Amps: 87 A 76 A 61 A

Total Load: 23500 VA 20500 VA 17000 VA

29 Space -- 1 -- -- 1 -- Space 30

27 Space -- 1 -- -- 1 -- Space 28

25 Space -- 1 -- -- 1 -- Space 26

23 Space -- 1 -- -- 1 -- Space 24

21 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 22

19 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 20

17 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 18

15 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 16

-- 13 -- -- -- -- 3.5 kVA 0.0 kVA 1 20 A Spare 14

1 11 3#10, 1#10(G) IN 3/4"C Heat Tracing 30 A 2 3.5 kVA 0.0 kVA 1 20 A Spare 12

-- 9 -- -- -- -- 3.5 kVA 3.5 kVA -- -- -- -- 10 --

1 7 3#10, 1#10(G) IN 3/4"C Heat Tracing 30 A 2 3.5 kVA 3.5 kVA 2 30 A Heat Tracing 3#10, 1#10(G) IN 3/4"C 8 1

-- 5 -- -- -- -- 10.0 kVA 3.5 kVA -- -- -- -- 6 --

-- 3 -- -- -- -- 10.0 kVA 3.5 kVA 2 30 A Heat Tracing 3#10, 1#10(G) IN 3/4"C 4 1

1 3#3, 1#8(G) IN 1-1/4"C 45kVA Transformer 20 A 3 10.0 kVA 3.0 kVA 1 20 A Unit Heater 2#12, 1#12(G) IN 3/4"C 2

Note CKT Branch Feeder Load Name Trip Poles A B C Poles Trip Load Name Branch Feeder CKT Note

Enclosure: NEMA 1

Mounting: Surface Wires: 4 Mains Rating: 100 A

Supply From: Phases: 3 Mains Type: MLO

Location: Volts: 480/277 Wye A.I.C. Rating: 60 kAIC

Branch Panel: PP-1

Notes:

Total Est. Demand Current: 23 A

Total Conn. Current: 23 A

Total Est. Demand: 8420 VA

Total Conn. Load: 8420 VA

Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Total Amps: 30 A 20 A 20 A

Total Load: 3620 VA 2400 VA 2400 VA

41 Space -- 1 -- -- 1 -- Space 42

39 Space -- 1 -- -- 1 -- Space 40

37 Space -- 1 -- -- 1 -- Space 38

35 Space -- 1 -- -- 1 -- Space 36

33 Space -- 1 -- -- 1 -- Space 34

31 Space -- 1 -- -- 1 -- Space 32

29 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 30

27 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 28

25 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 26

23 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 24

21 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 22

19 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 20

17 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 18

15 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 16

13 Spare 20 A 1 0.0 kVA 1.2 kVA 1 20 A Exhaust Fan 2#12, 1#12(G) in 3/4"C 14

11 2#12, 1#12(G) in 3/4"C FA Control Panel 20 A 1 0.5 kVA 0.5 kVA 1 20 A Misc. Control Panel 2#12, 1#12(G) in 3/4"C 12

9 2#12, 1#12(G) in 3/4"C JP Control Panel 20 A 1 0.5 kVA 0.5 kVA 1 20 A Misc. Control Panel 2#12, 1#12(G) in 3/4"C 10

7 2#12, 1#12(G) in 3/4"C FP Control Panel 20 A 1 0.5 kVA 0.5 kVA 1 20 A Misc. Control Panel 2#12, 1#12(G) in 3/4"C 8

5 2#12, 1#12(G) in 3/4"C Pump House Recs. 20 A 1 0.7 kVA 0.7 kVA 1 20 A Pump House Recs. 2#12, 1#12(G) in 3/4"C 6

3 2#12, 1#12(G) in 3/4"C Pump House Recs. 20 A 1 0.7 kVA 0.7 kVA 1 20 A Pump House Recs. 2#12, 1#12(G) in 3/4"C 4

1 2#12, 1#12(G) in 3/4"C Pump House Recs. 20 A 1 0.7 kVA 0.7 kVA 1 20 A Pump House Recs. 2#12, 1#12(G) in 3/4"C 2

Note CKT Branch Feeder Load Name Trip Poles A B C Poles Trip Load Name Branch Feeder CKT Note

Main Lugs Only: No

Enclosure: NEMA 1 MCB Rating: 175 A

Mounting: Surface Wires: 4 Mains Rating: 225 A

Supply From: Phases: 3 Mains Type: MCB

Location: Volts: 120/208 Wye A.I.C. Rating: 22 kAIC

Branch Panel: PP-2 Fire Pump House

Pad Mounted Transformer

Fire Pump House

PP-1

FIRE SUPPRESSION SYSTEM ABORT SWITCH STATION

FIRE ALARM AND DETECTION

XX

XXX

XXXX

F

F

ABBREVIATIONS

WALL MOUNTED SMOKE DETECTOR

X - X

X - X

NOTE:

SYMBOLS SHOWN ARE FOR REFERENCE

ONLY AND DO NOT CONSTITUTE A

CHECK LIST OF DEVICES REQUIRED BY

THE CONTRACT

CONTROL PANEL

THE FOLLOWING LABELS ARE USED TO INDICATE VARIOUS PANEL TYPES.

FACP —FIRE ALARM CONTROL PANEL

FACU —FIRE ALARM CONTROL UNIT

FATC —FIRE ALARM TERMINAL CABINET

FNAP —FIRE ALARM NOTIFICATION APPLIANCE PANEL

ACU —FIRE ALARM VOICE EVACUATION PANEL

FAA —FIRE ALARM ANNUNCIATOR PANEL

FSCP —FIRE SUPPRESSION CONTROL PANEL

FPT —FIRE WATER STORAGE TANK MONITOR

FPC —FIRE PUMP CONTROLLER

DACT —DIGITAL ALARM COMMUNICATOR TRANSMITTER

BATT —BATTERY CABINET

LOC —LOCAL OPERATING CONSOLE

FDRS —FIRE DEPARTMENT RADIO SYSTEM

MANUAL PULL STATION

THE FOLLOWING SUBSCRIPTS ARE USED TO INDICATE THE VARIOUS TYPES OF MANUAL

STATIONS, FIRE SUPPRESSION SYSTEM CONTROL AND/OR ABORT SWITCHES.

NO SUBSCRIPT — STANDARD FIRE ALARM PULL STATION

CA — CLEAN AGENT

CO2 — CARBON DIOXIDE

CVR —PROTECTIVE COVER (POTENTAILLY WITH LOCAL PIEZO HORN)

DC — DRY CHEMICAL

DL — DELUGE SPRINKLER

FO — FOAM

K — KEY ACTIVATED

PRE — PREACTION SYSTEM

WC — WET CHEMICAL

WM — WATER MIST

WS — WATER SPRINKLER

WP — WATER PROOF

XP — EXPLOSION PROOF

CEILING MOUNTED SMOKE DETECTOR

THE FOLLOWING SUBSCRIPTS ARE USED TO INDICATE THE VARIOUS TYPES OF SMOKE

DETECTORS.

NO SUBSCRIPT — STANDARD AREA PROTECTION

A — ATRIUM SMOKE CONTROL

CO — CARBON MONOXIDE SENSOR

D — MOUNTED AT RETURN AIR DUCT OPENING. SEE DETAIL [___]

E — ELEVATOR RECALL

F — FIRE/SMOKE DOOR RELEASE

R — CLEAN AGENT RELEASE

S — STAIR PRESSURIZATION

U — MOUNTED UNDER RAISED FLOOR

G — DETECTOR WITH GUARD

XP — EXPLOSION PROOF IS INTRINSICALLY SAFE

SB — SOUNDER BASE

IB — ISOLATOR BASE

WP — WEATHER PROOF

P — PHOTO ELECTRIC

I — IONIZATION

BR — BEAM REFLECTOR

BT — BEAM TRANSMITTER

S — AIR SAMPLING TYPE DETECTOR SAMPLING PORT

THE FOLLOWING LABELS ARE USED TO INDICATE THE VARIOUS TYPES OF DEVICES

AND/OR FUNCTIONS.

NAC — NOTIFICATION APPLIANCE POWER EXTENDER

MBS — MAINTENANCE BYPASS SWITCH

DLM — DISTANCE LOCATOR MODULE

DAS — DISTRIBUTED ANTENNAE SYSTEM FOR EMERGENCY RESPONDER

RADIO COMMUNICATION SYSTEM

THE FOLLOWING LABELS ARE USED TO INDICATE THE VARIOUS TYPES OF DEVICES

AND/OR FUNCTIONS.

DR — DOOR RELEASE FOR ELECTRIC LOCKS OR AUTO DOOR OVERRIDE

NA — NOTIFICATION APPLIANCE CIRCUIT INTERFACE

FS — HVAC FAN SHUTDOWN INITIATION

SF — STAIR PRESSURIZATION INITIATION

BA — BUILDING AUTOMATION SYSTEM SIGNAL

BM — BUILDING MANAGEMENT SYSTEM SIGNAL

ER — ELEVATOR RECALL OPERATIONS INITIATION PER ANSI A17.1

ES — ELEVATOR SHUTDOWN INITIATION PER ANSI A17.1

AR — POLARITY SUPERVISED AUXILIARY EQUIPMENT

CM — ADDRESSABLE FIRE ALARM CONTROL MODULE

MM — ADDRESSABLE FIRE ALARM MONITOR MODULE

RM — ADDRESSABLE FIRE ALARM RELAY MODULE

SS — SURGE SUPPRESSION MODULE

A, AMP AMPERS

AF AMP FUSE OR AMP FRAME

AFC AVAILABLE FAULT CURRENT (SYMMETRICAL)AFF

AFF ABOVE FINISHED FLOOR

AIC AMPERE INTERRUPTING CAPACITY

AM AMMETER

AS AMP SWITCH OR AMMETER SWITCH

ASYM ASYMMETRICAL

AT AMP TRIP

ATS AUTOMATIC TRANSFER SWITCH

AWG AMERICAN WIRE GAUGE

BOF BOTTOM OF FIXTURE

B.S.C. BARE STRANDED COPPER CONDUCTOR

C CONDUIT

CAP CAPACITY OR CAPACITOR

CATV COMMUNITY ANTENNA TELEVISION

CB CIRCUIT BREAKER

CCTV CLOSED CIRCUIT TELEVISION

CKT, CCT CIRCUIT

CL CURRENT LIMITING

C.O. CONDUIT ONLY

CONN CONNECT OR CONNECTION

CU COPPER

DA DURESS ALARM

DB DOOR BELL

DISC DISCONNECT

DPST DOUBLE POLE SINGLE THROW

EC ELECTRICAL CONTRACTOR

EWC ELECTRIC WATER COOLER

ELEC ELECTRIC OR ELECTRICAL

ELEV ELEVATION OR ELEVATOR

EMERG, EM EMERGENCY

EPO EMERGENCY POWER OFF

EMT ELECTRICAL METAL TUBING

EG ENGINE GENERATOR

FDR FEEDER

FIXT FIXTURE

FLA FULL LOAD AMPERES

FLUOR FLUORESCENT

GRC, GCR GALVANIZED RIGID CONDUIT

GEC GROUNDING ELECTRODE CONDUCTOR

GEN GENERATOR

GFCI GROUND FAULT CIRCUIT INTERRUPTER

GFI, GF GROUND FAULT INTERRUPTER

GRD, GND, G GROUND

HID HIGH INTENSITY DISCHARGE

HOA HAND-OFF-AUTO

HP HORSEPOWER

HPS HIGH PRESSURE SODIUM

HZ HERTZ

IMC INTERMEDIATE METAL CONDUIT

IG ISOLATED GROUND

INCAND INCANDESCENT

JB JUNCTION BOX

KAIC THOUSAND AMPERE INTERRUPTING CAPACITY

KVA KILOVOLT AMPERES

KW KILOWATT

KWH KILOWATT HOUR

LTG LIGHTING

LV LOW VOLTAGE

MATV MASTER ANTENNA TELEVISION

MCA MINIMUM CIRCUIT AMPS

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MH MANHOLE, METAL HALIDE OR MOUNTING HEIGHT

MLO MAIN LUGS ONLY

N.C. NORMALLY CLOSED

NEC NATIONAL ELECTRICAL CODE

NIC NOT IN CONTRACT

NF NON FUSIBLE

NL NIGHT LIGHT

N.O. NORMALLY OPEN

NTS NOT TO SCALE

OCP OVER CURRENT PROTECTION

OL OVERLOADS

P POLE

PB PULLBOX

PH OR Ø PHASE

PNL PANEL

POC POINT OF CONNECTION

PR PAIR

PVC POLYVINYL CHLORIDE

PWR POWER

REC RECEPTACLE

RGS RIGID GALVANIZED STEEL

RX REQUEST TO EXIT

SOL SOLENOID

SPKR SPEAKER

SPST SINGLE POLE SINGLE THROW

SPTD SINGLE POLE DOUBLE THROW

SW SWITCH

SWBD SWITCHBOARD

SYM SYMMETRICAL

TEL TELEPHONE

TGB TELECOMMUNICATIONS GROUNDING BUSBAR

TRANSF TRANSFORMER

TTB TELEPHONE TERMINAL BACKBOARD

TV TELEVISION

TYP TYPICAL

UG UNDERGROUND

UON UNLESS OTHERWISE NOTED

V VOLT

VA VOLT AMPERS

VD VOLTAGE DROP

VM VOLT METER

VS VOLT METER SWITCH

W WATTS OR WIRE

WG WIRE GUARD

W/ WITH

W/O WITHOUT

WP WEATHERPROOF

XFORM TRANSFORMER

XP EXPLOSION PROOF

WALL MOUNTED VISUAL NOTIFICATION

APPLIANCE.

WALL MOUNTED AUDIBLE NOTIFICATION APPLIANCE

WALL MOUNTED REMOTE ALARM INDICATOR

WALL MOUNTED REMOTE ALARM INDICATOR AND TEST STATION

CEILING MOUNTED REMOTE ALARM INDICATOR

J

FIREMAN'S EMERGENCY TELEPHONE [JACK] [IN

CABINET]

J - WALL MOUNTED JACK

DOOR RELEASE FOR MAGNETICALLY HELD SMOKE DOORS

F

F

RTS

WALL MOUNTED AUTOMATIC HEAT DETECTOR

DUCT SMOKE DETECTOR

D

X - X

X - X

CEILING MOUNTED AUTOMATIC HEAT DETECTOR

THE FOLLOWING SUBSCRIPTS ARE USED TO INDICATE THE VARIOUS TYPES OF

HEAT DETECTORS.

NO SUBSCRIPT — STANDARD AREA PROTECTION

E — ELEVATOR SHUT DOWN

R — PREACTION SPRINKLER RELEASING

U — MOUNTED UNDER RAISED FLOOR

G — DETECTOR WITH GUARD

WP — WEATHER PROOF

IB — ISOLATOR BASE

XP — EXPLOSION PROOF, FIXED TEMPERATURE

(135 DEGREE, UON) CLASS 1, GROUP C

RF — COMBINATION RATE OF RISE/FIXED TEMPERATURE

(135 DEGREE)

F — FIXED HIGH TEMPERATURE (135 DEGREE)

RC — RATE COMPENSATED FIXED TEMPERATURE (135 DEGREE, UON)

THE FOLLOWING SUBSCRIPTS ARE USED TO INDICATE THE VARIOUS TYPES OF

NOTIFICATION DEVICES.

NO SUBSCRIPT — STANDARD OCCUPANT NOTIFICATION

CA — CLEAN AGENT

CO2 — CARBON DIOXIDE

HO — HIGH OUTPUT

G — DEVICE WITH GUARD

WP — WEATHER PROOF

XP — EXPLOSION PROOF

F

SPRINKLER OR STANDPIPE FLOW ALARM SWITCH

SPRINKLER VALVE TAMPER SWITCH

SOLENOID VALVE FOR PREACTION OR DELUGE SPRINKLER SYSTEM

SPRINKLER AIR PRESSURE MONITOR SWITCH FOR

PRE-ACTION OR DRY PIPE SPRINKLER SYSTEM

XXX THE FOLLOWING LABELS ARE USED TO INDICATE THE VARIOUS TYPES OF DEVICES AND/OR

FUNCTIONS.

AIM — ADDRESSABLE INPUT MONITOR MODULE

ST — SPRINKLER TRIM PIPING CUTOFF VALVE SUPERVISORY SWITCH

SR — SPRINKLER PREACTION VALVE RELEASING SOLENOID

KA — KITCHEN HOOD EXTINGUISHING SYSTEM ALARM SWITCH

MANUAL ACTIVATION STATION - KEY OPERATED

K

1.

NOTE:

WALL MOUNT VISUAL AND COMBINATION

AUDIO/VISUAL NOTIFICATION APPLIANCES AT+80"

AFF TO BOTTOM OF LENS, UON.

WALL MOUNTED COMBINATION AUDIBLE/VISUAL

NOTIFICATION APPLIANCE.

CEILING MOUNTED VISUAL NOTIFICATION

APPLIANCE

CEILING MOUNTED COMBINATION AUDIBLE/VISUAL NOTIFICATION APPLIANCE

C

WF

VS

REL

LA

S

SPRINKLER WATER FLOW ACTIVATED AUDIBLE DEVICEF

US Army Corps of Engineers ®

SHEET ID

U S

AR

M Y C O R

PS

O F

EN

G

IN

EE

R S

D R

AW

N B Y:

D

ES

IG

N

ED

B Y:

SU

BM

IT

TE

D B Y:

SI

ZE

C H

EC

KE

D B Y:

AN

SI

D

IS

SU

E D

AT

E:

C O N

TR

AC

T N O

SO

LI

C

IT

AT

IO

N N O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D

AT

E

M

AR

K

D

ES

C R

IP

TI

O N

Fi le P at h:

Pl ot D at e:

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

N

EW

D

AI

R Y

FO

R

AG

E R

ES

EA

R C H C

EN

TE

R

Au to de sk D oc s:

//1 5_ U

SD

A_ D

FR

C _2 2/ -F -A

LL

-C en tra l.r vt

1/ /2 5:

:1

PM

FA-001-A

FI

R E

AL

AR

M A

BB

R

EV

IA

TI

O N S, S

YM

BO

LS

, A N D

N O

TE

S

- A R

EA

A

PR

AI

R

IE

D U S

AC

, W I

O M

AH

A D

IS

TR

IC

T

H D R

AR

LI

N G

TO

N , V

IR

G

IN

IA

B.

D U H

AC

EK

T.

F R

EE

M

AN

G . K

LE

IM

AN

J.

W

AR

BO

YS

/0 8/

W F2 0C

W F2 1C

GENERAL NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

DRAWINGS ARE DIAGRAMATIC: EXACT LOCATION,

MOUNTING HEIGHTS OF EQUIPMENT AND ROUTING OF

RACEWAYS SHALL BE COORDINATED WITH THE

EQUIPMENT REQUIREMENTS AND FIELD CONDITIONS.

CONTRACTOR SHALL FURNISH AND INSTALL ALL

INCIDENTAL ACCESSORIES NECESSARY TO MAKE THE

FIRE ALARM WORK COMPLETE AND READY FOR

OPERATION.

CONDUIT SHALL BE A MINIMUM OF 3/4" DIAMETER.

ALL CABLE AND CONDUIT SHALL BE SUPPORTED FROM THE

BUILDING STRUCTURE, INDEPENDENT OF OTHER SYSTEMS

INCLUDING PLUMBING PIPING, HVAC DUCTWORK, DROP

CEILING SUPPORTS, ETC

ALL COMPONENTS SHOWN ON THE RISER DIAGRAM, BUT

NOT ON THE PLAN OR VICE VERSA, SHALL BE INCLUDED AS

IF SHOWN ON BOTH.

ELEMENTS OF THE FIRE ALARM WORK SHALL BE

INSTALLED SUCH THAT AT COMPLETION THE ELEMENT

SHALL BE "FULLY AND REASONABLY ACCESSIBLE".

ELEMENTS OF THE FIRE ALARM WORK INCLUDE, BUT ARE

NOT LIMITED TO CABINETS, PANELS, JUNCTION BOXES,

AND ALL MAINTENANCE ACCESS POINTS. "FULLY AND

REASONABLY ACCESSIBLE" SHALL BE DEFINED AS;

CAPABLE OF BEING ACCESSED FOR SERVICE, REPAIR OR

REPLACEMENT BY AN AVERAGE SIZED INDIVIDUAL, ON A

LADDER IF NECESSARY, AND CAPABLE OF BEING SERVICED

OR REMOVED WITHOUT REMOVING, MODIFYING OR

DISTORTING OTHER COMPONENTS OF THE WORK OF

OTHER TRADES. CONFLICTS WITH MEETING THIS

REQUIRMENT SHALL BE BROUGHT TO THE ATTENTION OF

THE OWNER IN A TIMELY MANNER.

ALL FIRE ALARM DEVICES IN SPACES WITH FINISHED

CEILINGS SHALL BE INSTALLED CENTER OF TILE OR

ALIGNED WITH CEILING COMPONENTS WITH NO VISIBLE

DEVIATION IN ACCORDANCE WITH THE ARCHITECTURAL

REFLECTED CEILING PLAN. COORDINATE CEILING

MOUNTED DEVICES WITH CEILING CONTRACTOR AND

INSTALL AS SHOWN ON THE REFLECTED CEILING PLANS.

VERIFY LOCATION AND CONNECTION REQUIREMENTS FOR

EQUIPMENT PROVIDED BY OTHER TRADES PRIOR TO

ROUGH-IN.

COORDINATE ALL DIMENSIONS & WIRING REQUIREMENTS

ON ALL PRE-PURCHASED EQUIPMENT WITH FINAL

APPROVED SHOP DWGS.

R

TA

/0 8/

Ad de nd um

- I nq ui ry

/2 1/

FIRE SUPPRESSION SYSTEM ABORT SWITCH STATION

FIRE ALARM AND DETECTION

XX

XXX

XXXX

F

F

ABBREVIATIONS

WALL MOUNTED SMOKE DETECTOR

X - X

X - X

NOTE:

SYMBOLS SHOWN ARE FOR REFERENCE

ONLY AND DO NOT CONSTITUTE A

CHECK LIST OF DEVICES REQUIRED BY

THE CONTRACT

CONTROL PANEL

THE FOLLOWING LABELS ARE USED TO INDICATE VARIOUS PANEL TYPES.

FACP —FIRE ALARM CONTROL PANEL

FACU —FIRE ALARM CONTROL UNIT

FATC —FIRE ALARM TERMINAL CABINET

FNAP —FIRE ALARM NOTIFICATION APPLIANCE PANEL

ACU —FIRE ALARM VOICE EVACUATION PANEL

FAA —FIRE ALARM ANNUNCIATOR PANEL

FSCP —FIRE SUPPRESSION CONTROL PANEL

FPT —FIRE WATER STORAGE TANK MONITOR

FPC —FIRE PUMP CONTROLLER

DACT —DIGITAL ALARM COMMUNICATOR TRANSMITTER

BATT —BATTERY CABINET

LOC —LOCAL OPERATING CONSOLE

FDRS —FIRE DEPARTMENT RADIO SYSTEM

MANUAL PULL STATION

THE FOLLOWING SUBSCRIPTS ARE USED TO INDICATE THE VARIOUS TYPES OF MANUAL

STATIONS, FIRE SUPPRESSION SYSTEM CONTROL AND/OR ABORT SWITCHES.

NO SUBSCRIPT — STANDARD FIRE ALARM PULL STATION

CA — CLEAN AGENT

CO2 — CARBON DIOXIDE

CVR —PROTECTIVE COVER (POTENTAILLY WITH LOCAL PIEZO HORN)

DC — DRY CHEMICAL

DL — DELUGE SPRINKLER

FO — FOAM

K — KEY ACTIVATED

PRE — PREACTION SYSTEM

WC — WET CHEMICAL

WM — WATER MIST

WS — WATER SPRINKLER

WP — WATER PROOF

XP — EXPLOSION PROOF

CEILING MOUNTED SMOKE DETECTOR

THE FOLLOWING SUBSCRIPTS ARE USED TO INDICATE THE VARIOUS TYPES OF SMOKE

DETECTORS.

NO SUBSCRIPT — STANDARD AREA PROTECTION

A — ATRIUM SMOKE CONTROL

D — MOUNTED AT RETURN AIR DUCT OPENING. SEE DETAIL [___]

E — ELEVATOR RECALL

F — FIRE/SMOKE DOOR RELEASE

R — CLEAN AGENT RELEASE

S — STAIR PRESSURIZATION

U — MOUNTED UNDER RAISED FLOOR

G — DETECTOR WITH GUARD

XP — EXPLOSION PROOF IS INTRINSICALLY SAFE

SB — SOUNDER BASE

IB — ISOLATOR BASE

SS — SINGLE STATION 120VAC

P — PHOTO ELECTRIC

I — IONIZATION

BR — BEAM REFLECTOR

BT — BEAM TRANSMITTER

S — AIR SAMPLING TYPE DETECTOR SAMPLING PORT

THE FOLLOWING LABELS ARE USED TO INDICATE THE VARIOUS TYPES OF DEVICES

AND/OR FUNCTIONS.

NAC — NOTIFICATION APPLIANCE POWER EXTENDER

MBS — MAINTENANCE BYPASS SWITCH

DLM — DISTANCE LOCATOR MODULE

DAS — DISTRIBUTED ANTENNAE SYSTEM FOR EMERGENCY RESPONDER

RADIO COMMUNICATION SYSTEM

THE FOLLOWING LABELS ARE USED TO INDICATE THE VARIOUS TYPES OF DEVICES

AND/OR FUNCTIONS.

DR — DOOR RELEASE FOR ELECTRIC LOCKS OR AUTO DOOR OVERRIDE

NA — NOTIFICATION APPLIANCE CIRCUIT INTERFACE

FS — HVAC FAN SHUTDOWN INITIATION

SF — STAIR PRESSURIZATION INITIATION

BA — BUILDING AUTOMATION SYSTEM SIGNAL

BM — BUILDING MANAGEMENT SYSTEM SIGNAL

ER — ELEVATOR RECALL OPERATIONS INITIATION PER ANSI A17.1

ES — ELEVATOR SHUTDOWN INITIATION PER ANSI A17.1

AR — POLARITY SUPERVISED AUXILIARY EQUIPMENT

CM — ADDRESSABLE FIRE ALARM CONTROL MODULE

MM — ADDRESSABLE FIRE ALARM MONITOR MODULE

RM — ADDRESSABLE FIRE ALARM RELAY MODULE

SS — SURGE SUPPRESSION MODULE

A, AMP AMPERS

AF AMP FUSE OR AMP FRAME

AFC AVAILABLE FAULT CURRENT (SYMMETRICAL)AFF

AFF ABOVE FINISHED FLOOR

AIC AMPERE INTERRUPTING CAPACITY

AM AMMETER

AS AMP SWITCH OR AMMETER SWITCH

ASYM ASYMMETRICAL

AT AMP TRIP

ATS AUTOMATIC TRANSFER SWITCH

AWG AMERICAN WIRE GAUGE

BOF BOTTOM OF FIXTURE

B.S.C. BARE STRANDED COPPER CONDUCTOR

C CONDUIT

CAP CAPACITY OR CAPACITOR

CATV COMMUNITY ANTENNA TELEVISION

CB CIRCUIT BREAKER

CCTV CLOSED CIRCUIT TELEVISION

CKT, CCT CIRCUIT

CL CURRENT LIMITING

C.O. CONDUIT ONLY

CONN CONNECT OR CONNECTION

CU COPPER

DA DURESS ALARM

DB DOOR BELL

DISC DISCONNECT

DPST DOUBLE POLE SINGLE THROW

EC ELECTRICAL CONTRACTOR

EWC ELECTRIC WATER COOLER

ELEC ELECTRIC OR ELECTRICAL

ELEV ELEVATION OR ELEVATOR

EMERG, EM EMERGENCY

EPO EMERGENCY POWER OFF

EMT ELECTRICAL METAL TUBING

EG ENGINE GENERATOR

FDR FEEDER

FIXT FIXTURE

FLA FULL LOAD AMPERES

FLUOR FLUORESCENT

GRC, GCR GALVANIZED RIGID CONDUIT

GEC GROUNDING ELECTRODE CONDUCTOR

GEN GENERATOR

GFCI GROUND FAULT CIRCUIT INTERRUPTER

GFI, GF GROUND FAULT INTERRUPTER

GRD, GND, G GROUND

HID HIGH INTENSITY DISCHARGE

HOA HAND-OFF-AUTO

HP HORSEPOWER

HPS HIGH PRESSURE SODIUM

HZ HERTZ

IMC INTERMEDIATE METAL CONDUIT

IG ISOLATED GROUND

INCAND INCANDESCENT

JB JUNCTION BOX

KAIC THOUSAND AMPERE INTERRUPTING CAPACITY

KVA KILOVOLT AMPERES

KW KILOWATT

KWH KILOWATT HOUR

LTG LIGHTING

LV LOW VOLTAGE

MATV MASTER ANTENNA TELEVISION

MCA MINIMUM CIRCUIT AMPS

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MH MANHOLE, METAL HALIDE OR MOUNTING HEIGHT

MLO MAIN LUGS ONLY

N.C. NORMALLY CLOSED

NEC NATIONAL ELECTRICAL CODE

NIC NOT IN CONTRACT

NF NON FUSIBLE

NL NIGHT LIGHT

N.O. NORMALLY OPEN

NTS NOT TO SCALE

OCP OVER CURRENT PROTECTION

OL OVERLOADS

P POLE

PB PULLBOX

PH OR Ø PHASE

PNL PANEL

POC POINT OF CONNECTION

PR PAIR

PVC POLYVINYL CHLORIDE

PWR POWER

REC RECEPTACLE

RGS RIGID GALVANIZED STEEL

RX REQUEST TO EXIT

SOL SOLENOID

SPKR SPEAKER

SPST SINGLE POLE SINGLE THROW

SPTD SINGLE POLE DOUBLE THROW

SW SWITCH

SWBD SWITCHBOARD

SYM SYMMETRICAL

TEL TELEPHONE

TGB TELECOMMUNICATIONS GROUNDING BUSBAR

TRANSF TRANSFORMER

TTB TELEPHONE TERMINAL BACKBOARD

TV TELEVISION

TYP TYPICAL

UG UNDERGROUND

UON UNLESS OTHERWISE NOTED

V VOLT

VA VOLT AMPERS

VD VOLTAGE DROP

VM VOLT METER

VS VOLT METER SWITCH

W WATTS OR WIRE

WG WIRE GUARD

W/ WITH

W/O WITHOUT

WP WEATHERPROOF

XFORM TRANSFORMER

XP EXPLOSION PROOF

WALL MOUNTED VISUAL NOTIFICATION

APPLIANCE.

WALL MOUNTED AUDIBLE NOTIFICATION APPLIANCE

WALL MOUNTED REMOTE ALARM INDICATOR

WALL MOUNTED REMOTE ALARM INDICATOR AND TEST STATION

CEILING MOUNTED REMOTE ALARM INDICATOR

J

FIREMAN'S EMERGENCY TELEPHONE [JACK] [IN

CABINET]

J - WALL MOUNTED JACK

DOOR RELEASE FOR MAGNETICALLY HELD SMOKE DOORS

F

F

RTS

WALL MOUNTED AUTOMATIC HEAT DETECTOR

DUCT SMOKE DETECTOR

D

X - X

X - X

CEILING MOUNTED AUTOMATIC HEAT DETECTOR

THE FOLLOWING SUBSCRIPTS ARE USED TO INDICATE THE VARIOUS TYPES OF

HEAT DETECTORS.

NO SUBSCRIPT — STANDARD AREA PROTECTION

E — ELEVATOR SHUT DOWN

R — PREACTION SPRINKLER RELEASING

U — MOUNTED UNDER RAISED FLOOR

G — DETECTOR WITH GUARD

WP — WEATHER PROOF

IB — ISOLATOR BASE

XP — EXPLOSION PROOF, FIXED TEMPERATURE

(135 DEGREE, UON) CLASS 1, GROUP C

RF — COMBINATION RATE OF RISE/FIXED TEMPERATURE

(135 DEGREE)

F — FIXED HIGH TEMPERATURE (135 DEGREE)

RC — RATE COMPENSATED FIXED TEMPERATURE (135 DEGREE, UON)

THE FOLLOWING SUBSCRIPTS ARE USED TO INDICATE THE VARIOUS TYPES OF

NOTIFICATION DEVICES.

NO SUBSCRIPT — STANDARD OCCUPANT NOTIFICATION

CA — CLEAN AGENT

CO2 — CARBON DIOXIDE

HO — HIGH OUTPUT

G — DEVICE WITH GUARD

WP — WEATHER PROOF

XP — EXPLOSION PROOF

F

SPRINKLER OR STANDPIPE FLOW ALARM SWITCH

SPRINKLER VALVE TAMPER SWITCH

SOLENOID VALVE FOR PREACTION OR DELUGE SPRINKLER SYSTEM

SPRINKLER AIR PRESSURE MONITOR SWITCH FOR

PRE-ACTION OR DRY PIPE SPRINKLER SYSTEM

XXX THE FOLLOWING LABELS ARE USED TO INDICATE THE VARIOUS TYPES OF DEVICES AND/OR

FUNCTIONS.

AIM — ADDRESSABLE INPUT MONITOR MODULE

ST — SPRINKLER TRIM PIPING CUTOFF VALVE SUPERVISORY SWITCH

SR — SPRINKLER PREACTION VALVE RELEASING SOLENOID

KA — KITCHEN HOOD EXTINGUISHING SYSTEM ALARM SWITCH

MANUAL ACTIVATION STATION - KEY OPERATED

K

1.

NOTE:

WALL MOUNT VISUAL AND COMBINATION

AUDIO/VISUAL NOTIFICATION APPLIANCES AT+80"

AFF TO BOTTOM OF LENS, UON.

WALL MOUNTED COMBINATION AUDIBLE/VISUAL

NOTIFICATION APPLIANCE.

CEILING MOUNTED VISUAL NOTIFICATION

APPLIANCE

CEILING MOUNTED COMBINATION AUDIBLE/VISUAL NOTIFICATION APPLIANCE

C

WF

VS

REL

LA

S

SPRINKLER WATER FLOW ACTIVATED AUDIBLE DEVICEF

US Army Corps of Engineers ®

SHEET ID

U S

AR

M Y C O R

PS

O F

EN

G

IN

EE

R S

D R

AW

N B Y:

D

ES

IG

N

ED

B Y:

SU

BM

IT

TE

D B Y:

SI

ZE

C H

EC

KE

D B Y:

AN

SI

D

IS

SU

E D

AT

E:

C O N

TR

AC

T N O

SO

LI

C

IT

AT

IO

N N O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D

AT

E

M

AR

K

D

ES

C R

IP

TI

O N

Fi le P at h:

Pl ot D at e:

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

N

EW

D

AI

R Y

FO

R

AG

E R

ES

EA

R C H C

EN

TE

R

Au to de sk D oc s:

//1 5_ U

SD

A_ D

FR

C _2 2/ -F -A

LL

-C en tra l.r vt

1/ /2 5:

:1

PM

FA-001-B

FI

R E

AL

AR

M A

BB

R

EV

IA

TI

O N S, S

YM

BO

LS

, A N D

N O

TE

S

- A R

EA

B

PR

AI

R

IE

D U S

AC

, W I

O M

AH

A D

IS

TR

IC

T

H D R

AR

LI

N G

TO

N , V

IR

G

IN

IA

B.

D U H

AC

EK

T.

F R

EE

M

AN

G . K

LE

IM

AN

J.

W

AR

BO

YS

/0 8/

W F2 0C

W F2 1C

GENERAL NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

DRAWINGS ARE DIAGRAMATIC: EXACT LOCATION,

MOUNTING HEIGHTS OF EQUIPMENT AND ROUTING OF

RACEWAYS SHALL BE COORDINATED WITH THE

EQUIPMENT REQUIREMENTS AND FIELD CONDITIONS

CONTRACTOR SHALL FURNISH AND INSTALL ALL

INCIDENTAL ACCESSORIES NECESSARY TO MAKE THE

FIRE ALARM WORK COMPLETE AND READY FOR

OPERATION.

CONDUIT SHALL BE A MINIMUM OF 3/4" DIAMETER.

ALL CABLE AND CONDUIT SHALL BE SUPPORTED FROM THE

BUILDING STRUCTURE, INDEPENDENT OF OTHER SYSTEMS

INCLUDING PLUMBING PIPING, HVAC DUCTWORK, DROP

CEILING SUPPORTS, ETC

ALL COMPONENTS SHOWN ON THE RISER DIAGRAM, BUT

NOT ON THE PLAN OR VICE VERSA, SHALL BE INCLUDED AS

IF SHOWN ON BOTH.

ELEMENTS OF THE FIRE ALARM WORK SHALL BE

INSTALLED SUCH THAT AT COMPLETION THE ELEMENT

SHALL BE "FULLY AND REASONABLY ACCESSIBLE".

ELEMENTS OF THE FIRE ALARM WORK INCLUDE, BUT ARE

NOT LIMITED TO CABINETS, PANELS, JUNCTION BOXES,

AND ALL MAINTENANCE ACCESS POINTS. "FULLY AND

REASONABLE ACCESSIBLE" SHALL BE DEFINED AS;

CAPABLE OF BEING ACCESSED FOR SERVICE, REPAIR OR

REPLACEMENT BY AN AVERAGE SIZED INDIVIDUAL, ON A

LADDER IF NECESSARY, AND CAPABLE OF BEING SERVICED

OR REMOVED WITHOUT REMOVING, MODIFYING OR

DISTORTING OTHER COMPONENTS OF THE WORK OF

OTHER TRADES. CONFLICTS WITH MEETING THIS

REQUIRMENT SHALL BE BROUGHT TO THE ATTENTION OF

THE OWNER IN A TIMELY MANNER.

ALL FIRE ALARM DEVICES IN SPACES WITH FINISHED

CEILINGS SHALL BE INSTALLED CENTER OF TILE OR

ALIGNED WITH CEILING COMPONENTS WITH NO VISIBLE

DEVIATION IN ACCORDANCE WITH THE ARCHITECTURAL

REFLECTED CEILING PLAN. COORDINATE CEILING

MOUNTED DEVICES WITH CEILING CONTRACTOR AND

INSTALL AS SHOWN ON THE REFLECTED CEILING PLANS.

VERIFY LOCATION AND CONNECTIONS REQUIREMENTS

FOR EQUIPMENT PROVIDED BY OTHER TRADES PRIOR TO

ROUGH-IN.

COORDINATE ALL DIMENSIONS & WIRING REQUIREMENTS

ON ALL PRE-PURCHASED EQUIPMENT WITH FINAL

APPROVED SHOP DWGS.

R

TA

/0 8/

Ad de nd um

- I nq ui ry

/2 1/

Q-401-A - FLOOR PLAN - FIRST FLOOR - ENLARGED - AREA A - LAB & ADMIN
Q-503-A - LABORATORY CTR SCHEDULE & DETAILS - AREA A - LAB & ADMIN
ES-101 - ELECTRICAL SITE PLAN
ES-103 - BADGER WELL 5 0 WELL PUMP DIAGRAM AND FIRE PUMP HOUSE SCHEDULES
FA-001-A - FIRE ALARM ABBREVIATIONS, SYMBOLS, AND NOTES - AREA A
FA-001-B - FIRE ALARM ABBREVIATIONS, SYMBOLS, AND NOTES - AREA B