This announcement constitutes a solicitation for the FY22 OMA Multi-Domain Task Force (MDTF) #3 project at Building 300, Helemano Military Reservation. The U.S. Army Corps of Engineers, Honolulu District intends to issue a solicitation to renovate and repair the building for use as an MDTF Brigade Headquarters and Secure Operations Facility. The project scope includes new elevator, UPS, emergency generator, utility extensions, communications, site infrastructure and improvements, site lighting, grading, parking, fencing and landscaping. The estimated period of performance is 912 calendar days with a projected value between $50-100 million. The acquisition will use lowest priced technically acceptable source selection based on experience, past performance, technical approach, and price. The solicitation number is W9128A22R0016. Offerors must register in SAM and check for solicitation changes on the website. The NAICS code is 236220 with a $39.5 million revenue size standard. The Government will award a firm-fixed-price construction contract.

View the file

Other files

Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

FY22 Multi-Domain Task Force #3, Building 300, Helemano Military Reservation, Oahu, Haw aii

See Continuation Page.

1. CONTRACT ID CODE PAGE OF PAGES

J 1 3

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W9128A22R0016

X 9B. DATED (SEE ITEM 11)

07-Jul-2022

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO.

Am-0005

5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

15-Aug-2022

CODE

CONTRACTING DIVISION

BLDG 230 OTAKE ST.

FORT SHAFTER HI 96858

W9128A 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

W9128A22R0016 Am-0005

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

1. CHANGES TO SPECIFICATIONS. Attached hereto are revised pages/paragraphs to the specifications. The revision mark “(Am-0005)” is shown on each revised page.

a. REVISED SECTIONS. The following are revised pages to the solicitation. Changes are marked in “*” asterisks, “strikethrough”, “bold”, and/or clouded in “Red”.

Section 00 22 16 – Page 9 Specifications, Table of Contents – Page 2 Section 01 33 00 – Pages 20-104 Section 01 45 35 – Pages 6-8 Section 10 28 13 – Pages 3-5

b. NEW SECTIONS. The following are new pages to the solicitation.

Section 00 60 00, Attachment A – Requests for Information (#10-36)

c. REPLACED SECTIONS. The following section from the solicitation has been deleted in its entirety and replaced with the section attached to this amendment.

Section 07 24 00 Section 10 44 16

2. CHANGES TO DRAWINGS

a. REVISED DRAWINGS. The following revised drawings replace like-numbered drawings and are issued herewith:

Sheet ID Mark G-001 5

GS101 5

GS104 5

GS105 5

GS106 5

CS101 5

CS102 5

CS503 5

CS504 5

S-002 5

SD111 5

SD112 5

SD121 5

SD122 5

S-112 5 S-121 5 S-122 5 S-202 5 S-203 5 S-503 5 S-504 5

AD111 5

AD112 5

AD113 5

AD114 5

Am-0005

AD115 5

AD117 5

AD119 5

AD212 5

AD213 5

AD214 5

A-201 5 A-211 5 A-212 5 A-213 5 A-214 5 A-215 5 A-216 5 A-311 5 A-503 5 A-504 5 A-506 5 A-509 5 A-517 5 A-601 5 A-602 5 A-604 5

AI202 5

AI203 5

AI204 5

AI205 5

AI207 5

AI208 5

AI209 5

AI210 5

AI211 5

AI212 5

AI213 5

AF506 5

M-002 5 M-111 5 M-112 5 M-113 5 M-115 5 M-121 5 M-122 5 M-132 5 M-401 5

MP115 5

T-502 5

TS101 5

TY111 5

3. The proposal due date and time is extended to August 31, 2022 at 2:00 PM Hawaii Standard Time (see Standard Form 1442, Block 13A).

FY22 Multi-Domain Task Force #3, Building 300, Helemano Military Reservation, Oahu, Haw aii

COLIN K WAKI (808) 835-4393

NOTE: In sealed bid solicitations "offer" and "offeror" mean "bid" and "bidder".

10. THE GOVERNMENT REQUIRES PERFORMANCE OF THE WORK DESCRIBED IN THESE DOCUMENTS

NEGOTIATED

07-Jul-2022

(RFP)

(IFB)

X

CALL:

B. TELEPHONE NO. (Include area code) (NO COLLECT CALLS)

2. TYPE OF SOLICITATION

SEALED BID

3. DATE ISSUED

9. FOR INFORMATION A. NAME

SOLICITATION

NSN 7540-01-155-3212 1442-101 STANDARD FORM 1442 (REV. 4-85)

Prescribed by GSA FAR (48 CFR) 53.236-1(e)

11. The Contractor shall begin performance w ithin _______7 calendar days and complete it w ithin ________1020 calendar days after receiving aw ard, X notice to proceed. This performance period is X mandatory, negotiable. (See _________________________52.211-10

12 A. THE CONTRACTOR MUST FURNISH ANY REQUIRED PERFORMANCE AND PAYMENT BONDS?

(If "YES," indicate within how many calendar days after award in Item 12B.)

X YES NO

13. ADDITIONAL SOLICITATION REQUIREMENTS:

A. Sealed offers in original and __________1 copies to perform the w ork required are due at the place specif ied in Item 8 by ___________ local time ______________31 Aug 2022 (date). If this is a sealed bid solicitation, offers must be publicly opened at that time.

shall be marked to show the offeror's name and address, the solicitation number, and the date and time offers are due.

B. An offer guarantee is, X is not required.

C. All offers are subject to the (1) w ork requirements, and (2) other provisions and clauses incorporated in the solicitation in full text or by reference.

D. Offers providing less than _______90 calendar days for Government acceptance after the date offers are due w ill not be considered and w ill be rejected.

SOLICITATION, OFFER,

AND AWARD

(Construction, Alteration, or Repair)

1. SOLICITATION NO.

IMPORTANT - The "offer" section on the reverse must be fully completed by offeror.

4. CONTRACT NO.

7. ISSUED BY CODE

CONTRACTING DIVISION

BLDG 230 OTAKE ST.

FORT SHAFTER HI 96858

W9128A

PAGE OF PAGES

CODE W9128A

(Title, identifying no., date):

12B. CALENDAR DAYS

02:00 PM (hour) Sealed envelopes containing offers

CONTRACTING DIVISION

BLDG 230 OTAKE ST.

FORT SHAFTER HI 96858

5. REQUISITION/PURCHASE REQUEST NO. 6. PROJECT NO.

8. ADDRESS OFFER TO (If Other Than Item 7)

FAX:TEL: TEL: FAX:

W9128A22R0016 1 OF 2

(Am-0005)

Section 00 22 16 – 9

Factor 2, Past Performance

Adjectival Rating Definition

Acceptable Based on the Offeror’s performance record, the Government has a reasonable expectation that the Offeror will successfully perform the required effort, or the Offeror’s performance record is Unknown.

Unacceptable Based on the Offeror’s performance record, the Government does not have a reasonable expectation that the Offeror will be able to successfully perform the required effort.

Note: In the case of an Offeror without a record of past performance or for whom information on past performance is not available or so sparse that no meaningful past performance rating can be reasonably assigned, the Offeror may not be evaluated favorably or unfavorably on past performance (See FAR 15.305(a)(2)(iv)). Therefore, the Offeror shall be determined to have an Unknown past performance. In the context of acceptability / unacceptability, “Unknown” shall be considered “Acceptable”.

6.0 Volume 1, Factor 3 – Technical Approach

6.1 Volume 1, Tab 4: Technical Approach

6.1.1 Submission Requirements:

The Offeror shall provide, at a minimum, a narrative description that includes the following:

a. Describe how it will manage its resources, including its staff, subcontractors and suppliers.

b. Describe how it will manage the major elements of work and sequencing/construction phasing.

c. Describe how it will coordinate with the security monitoring contractor also present at the site.

d. Explain how it will address logistical, personnel, material/equipment sourcing, and transportation challenges of executing this project in a site with sourcing and logistical challenges such as Hawaii or similar to Hawaii.

e. Describe its proposed approach to successful quality control.

f. Explain how SCIF construction will be completed in accordance with Construction Security Plan/ICD 705 to receive accreditation.

g. Explain phasing of SCIF work and administrative/office space work.

The Offeror shall not exceed the page limitation in paragraph 3.4.2. Any pages that exceed this limitation will not be considered. One (1) page may be submitted on a sheet not to exceed 11”x17”.

6.1.2 Evaluation Criteria

The Government will evaluate to determine whether the Offeror’s proposal complies with the submission requirements in paragraph 6.1.1. The Government will then assign an adjectival rating in accordance with paragraph 6.1.3.

6.1.3 Basis of Evaluation

The Government will use the following as the basis of evaluation:

Factor 3, Technical Approach

Adjectival Rating Description

Acceptable The proposal meets the minimum requirements of paragraph 6.1.1.

Unacceptable The proposal fails to meet the minimum requirements of paragraph 6.1.1.

FY22 Multi-Domain Task Force #3 Building 300 Helemano Military Reservation, Oahu, Hawaii

RFI # Reference Question Government Response

10 08 51 13 The calculated worst case wind load is 53.2 psf for this project using the RFP information. This aligns closely with the note under paragraph 1.5.2 Tests of spec Section 08 51 13 (Aluminum Windows), which calls for test reports reflecting 50 psf. The question comes from paragraph 1.5.1 calls for 80 psf. This appears to be either an overdesign (a question of increased cost) or a misstatement of the overload testing where they increase the uniform load by 50%. Please confirm the required wind load.

See revised Section 08 51 13, Paragraph 1.5.1, per Am-0002.

11 S131/S509 Please verify that the ¾” Plywood with 10ga sheet metal is used at the ceiling only for the Arms Vault rooms and checkered plate is for the floor.

Sheet S131 indicates sheet metal above slab per detail K14/S509

Confirmed, the ¾” plywood with 10ga is for ceiling only inside Arms Vault.

The checkered plate is for floor above slab only inside Arms Vault.

12 A214 Please verify that the new windows are not required to mimic any historic architecture requirements.

Confirmed.

13 A-602 Drawing A-114 has door callout 120A for exterior door in Lobby 120.

Drawing schedule on A-602 lists this door as ALUM door and ALUM frame panel type A2. Drawing A-604 shows a type A2 door as Flush Panel w/ Transom. Detail L6 on drawing A-503 shows metal frame and Detail K2 on drawing AI207 shows ordinary door w/out transom. Please confirm whether this door is Aluminum and type A2.

See revised Sheet A-604, per Am-0005.

14 Site Visit Is it possible to reschedule a site visit? If not is it possible to include pictures of the access to the crawlspace as well as the crawlspace itself?

See new Section 00 60 00, Attachment C, per Am-0004.

15 Per the RFP Documents section 4.1.2 Relevant Contracts (C) it states the following “1. This contract involved renovation or new construction of administrative/office facilities. The final contract amount (after any modifications) was $25,000,000 or greater.”

Would the Government consider renovation or new construction projects of Bachelor Enlisted Quarters (BEQ) in lieu of administrative/office facilities projects?

No.

16 Since this project is in a BEQ Building, please confirm that BEQ projects would be considered relevant experience.

No.

17 For plumbing demo identified in Middle Wing, Survey does not indicate testing for asbestos of the tank insulation or pipe insulation in the crawl space. Does the Government have testing available for these areas?

See Section 01 57 19, Attachment B, per the original solicitation, for Hazmat Survey Report. The Contractor shall verify exact potential hazmat locations and volumes.

18 Drawing PD101 indicates removal of slabs to access underground piping, SD112 does not indicated slab demo in this area. Can this concrete removal scope be clarified?

See revised Sheets SD112 and S-112, per Am-0005.

19 There is an outside structure on the West Side of the middle wing, it was indicated on the walk thru that the structure is to be removed. AD111 does not indicate demolition in this area. Can this scope be clarified?

See revised Sheet AD111, per Am-0005.

Section 00 60 00, Attachment A

20 Please see photo below which shows metal baffles (?) on the overhangs.

Work is not identified or shown on the drawings for this item. Is there work associated with these? Are they structural?

See revised Sheets AD213 and AD214, per Am-0005. Existing metal baffles are to be removed.

21 We would like to kindly request for an extension to the bid deadline to allow more time for a more thorough review of a project of this magnitude to allow for more accurate and competitive pricing and also as there are multiple USACE projects currently bidding on the same day.

See revised SF1442, per Am-0004.

22 MP115 The phasing of this job is to complete Phase 1 construction to renovate the Middle and East wings with the Main building still occupied. Drawing MP115 shows chilled water piping running thru the Main building in order to serve the East Wing. How does this get accomplished while the Main Building is still occupied? Is temporary chilled water piping the runs above grade outside the Main Building to be provided to serve the East Wing until construction can start on the Main Building? Is this to be considered a Means and Methods by the Contractor? Please advise.

See Section 01 57 19, Attachment B, per the original solicitation, for Hazmat Survey Report. The Contractor shall verify exact potential hazmat locations and volumes.

23 Bid Date Helemano Building 300’s bid date of August 11th is the exact same bid dates as Aliamanu CDC and Schofield Barracks CDC, all USACE projects.

We recommend not having 3 projects bidding the same day! Please consider spacing them out. Even a day difference helps.

See revised SF1442, per Am-0004.

24 Arch Throughout architectural drawings, there are FEC and FEC1 type fire extinguisher cabinets called out, but specs only specify a semi recessed FEC. What is the difference between FEC and FEC1

See revised Section 10 44 16, per Am-0005.

25 A/602 Doors 154-156 are called out as door type G in door schedule, but no door type G detail provided on A604

See revised Sheet A-602, per Am-0005.

26 Arch Please provide Mirror sizes. Additionally, specs specify Mirr 1 (mirror w/ 5” Shelf) and Mirr 2. Architectural drawings did not show any mirrors w/ Shelves (MIRR1) please confirm if MIRR 1 type is used and if so specify locations.

See revised Sheet AF506, per Am-0005.

27 S122 Key note 10 is “Not Used”, but key note 10 points to CW8A wall between GL 15D-16 and GL D.7-E

See revised Sheet S-122, per Am-0005.

28 S402 Please provide Ramp Footing detail from GL 14 to GL 10 See Sheet S-402, Details H1, A9, and A15, per the original solicitation;

and revised Sheet S-121, Detail H1, per Am-0005.

29 S121 On GL F between GL 2/3, lines are darkened. Is this to depict a new wall to be installed? Or a new grade beam? Please confirm what is being depicted here and provide details to follow.

See revised Sheet S-121, per Am-0005.

30 E1/S503 See Detail E1/S503. Please provide top mat rebar sizes for D>1’6” condition.

See revised Sheet S-503, per Am-0005.

31 S114 Note 8 on S114 provides top and bottom rebar sizes and references detail E14/S504. Detail E14/S504 has 3 mats of rebar depicted. Please provide middle rebar mat sizing.

See revised Sheet S-504, per Am-0005.

32 A10/S203 Please provide sizing and dimensions for corner and top and bottom bar around RO on 2nd floor.

See revised Sheets S-202, Detail A1 and S-203, Detail A10, per Am-0005.

33 A9/S401 Please provide size and count for elevator pit slab and pit rebar. See revised Sheet S401, per Am-0002.

34 M-503 Details F7 & F14 on drawing M-503 indicate duct silencers should be provided at duct penetrations of sound attenuated and/or secure walls.

Many of the ductwork drawings M-111 to M-132 include a general note that states “duct penetrations of…..walls shall be per detail F7 (or F14), sheet M-503. There is no schedule or specifications for these duct silencers as well as any locations shown on the mechanical drawings. The locations of duct silencers along with sizes and specifications/schedule are usually provided. Please advise.

See revised Section 23 30 00 and revised Sheets M-111, M-112, M-113, M-115, M-121, M-122, M-132, and M-401, per Am-0005.

35 There are corner guards shown in the General Notes/Legend on Sheets A- 111 to A-119. Looking at the Floor Plan, it seems like there are no corner guards called out. Please advise if corner guards are required.

See Sheet AF601, per the original solicitation for CG-1 reference. See Sheets A-510, A-511, and A-512, per the original solicitation, for corner guard (CG-1) locations.

36 Section 08 33 13 for Coiling Counter Doors are included with the Specifications; however, it seems like no coiling counter doors are called out on the Door Schedule. Please confirm there are no coiling counter doors required.

Section 08 33 13 has been deleted in its entirety, per Am-0002.

22-R-0016 Am-0005
a. REVISED DRAWINGS. The following revised drawings replace like-numbered drawings and are issued herewith:
22-R-0016 - SF1442 Page 1
22-R-0016 - 00 22 16, Page 9
22-R-0016 - 00 60 00, Att. A - RFI (#10-36)

File details come from the government source that posted it. Updated .