A.2.11.3 W9128A22R0016 Drawings (Part 3 of 4).pdf
PDF 40 MB Posted
- Solicitation number
- W9128A22R0016
About this file
This document provides details on a federal contract solicitation by the U.S. Army Corps of Engineers Honolulu District. The solicitation is for the renovation and repair of Building 300 at Helemano Military Reservation to accommodate the Multi-Domain Task Force #3 and 307th ESB. Work includes installing a new elevator, UPS, emergency generator, utility extensions, communications and site infrastructure upgrades, lighting, fencing and landscaping. The acquisition will be lowest priced technically acceptable based on experience, past performance, technical approach and price. The project magnitude is between $50-100 million. The response deadline is not stated. The North American Industry Classification code is 236220 and the Small Business size standard is $39.5 million annual average revenue. The contract to be awarded will be firm-fixed-price. Offerors must register with the System for Award Management at sam.gov.
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ABC
ABC
ABC
ABC
DNDN
ABC
ABCABC
A B
C
ABC ABC
ABC
BC
ABC
BC
ABC
ABC
ABC
ABC ABC
ABCABC
7 6 5 4 3 2 189A9B101112131415C15D16171819202122
D
E
F
D.7
FX103
A1
FX104
H1
FX104
A1
FX101
A5
FX102
A11
FX105
A1
F15
FX502
F15
FX502
7 6 5 4 3 2 189A9B101112131415C15D16171819202122
D
E
FM4M6M8M9 M2 M1M10
MA
MB
MC
MD
ME
MF
M5 M3M7
D.7
E4
EA
EB
EC
ED
EE
E1E2E3
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
B
IM
/U
S H
I_ D
U
S A
C E
M
D T
F
B u ild in g
/R
Y J B
L D
G D
M M
F .r v t
/1
/2
:2
:5
P
M
FX001
O V
E R
A L L B
A S
E M
E N
T A
N D
S
T F
L O
O R
F
IR
E S
P R
IN
K
L E
R P
L A
N
H E
L E
M A
N O
M
IL
IT
A
R Y
R E
S E
R V
A T
IO
N
O
A H
U H
I
H O
N O
L U
L U
D
IS
T R
IC
T
B L D
G
R
O O
M
F
O R
T S
H A
F T
E R
H
I -5
J A
C O
B S
-A H
L J
V B
IS
H
O P
S T
S U
IT
E
H
O N
O L U
L U
H
I
J C
A M
P B
E L L
D N
G U
Y E
N
S Y
I
S B
A C
H T
E L H
E
IM
E R
M A
R C
H
W A
F
W A
-1 -D
-0
R T
A S
U B
M
IT
T A
L
F Y
M
D T
F
B
U
IL
D
IN
G
R Y
J
0 10' 20' 40'
PLAN NORTH
C B A
MW EW
KEY PLAN
MAIN BUILDING
1" = 20'-0"A1
OVERALL BASEMENT FIRE SPRINKLER PLAN
1" = 20'-0"H1
OVERALL 1ST FLOOR FIRE SPRINKLER PLAN
0 10' 20' 40'
6" FIRE SPRINKLER
RISER UP
6" FIRE SPRINKLER
RISER UP
ABCABCABC ABC ABC
ABC ABC
ABC
ABCABC
ABC ABC ABC
ABC
ABC
FX107
A1
FX106
H1
FX106
A1
FX102
A4
F15
FX502
F15
FX502
7 6 5 4 3 2 189A9B101112131415C15D16171819202122
D
E
FM4M6M8M9 M2 M1M10
MA
MB
MC
MD
ME
MF
M5 M3M7
D.7
E4
EA
EB
EC
ED
EE
E1E2E3
FX109
A1
FX108
H1
FX108
A1
F15
FX502
F15
FX502
7 6 5 4 3 2 189A9B101112131415C15D16171819202122
D
E
F
D.7
E4
EA
EB
EC
ED
EE
E1E2E3
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
B
IM
/U
S H
I_ D
U
S A
C E
M
D T
F
B u ild in g
/R
Y J B
L D
G D
M M
F .r v t
/1
/2
:2
:5
P
M
FX002
O V
E R
A L L
N D
A N
D
R D
F L O
O R
F
IR
E S
P R
IN
K
L E
R P
L A
N
H E
L E
M A
N O
M
IL
IT
A
R Y
R E
S E
R V
A T
IO
N
O
A H
U H
I
H O
N O
L U
L U
D
IS
T R
IC
T
B L D
G
R
O O
M
F
O R
T S
H A
F T
E R
H
I -5
J A
C O
B S
-A H
L J
V B
IS
H
O P
S T
S U
IT
E
H
O N
O L U
L U
H
I
J C
A M
P B
E L L
D N
G U
Y E
N
S Y
I
S B
A C
H T
E L H
E
IM
E R
M A
R C
H
W A
F
W A
-1 -D
-0
R T
A S
U B
M
IT
T A
L
F Y
M
D T
F
B
U
IL
D
IN
G
R Y
J
0 10' 20' 40'
PLAN NORTH
C B A
MW EW
KEY PLAN
MAIN BUILDING
0 10' 20' 40'
1" = 20'-0"A1
OVERALL 2ND FLOOR FIRE SPRINKLER PLAN
1" = 20'-0"J1
OVERALL 3RD FLOOR FIRE SPRINKLER PLAN
6" FIRE SPRINKLER
RISER UP
6" FIRE SPRINKLER
RISER DOWN
BC
ABC
ABC
ABC
ABC
ADOC
M103
SECURED VEST
M101
SSO
M102
DCO LAB
M104
RF LAB
M105
BDE HQ (CDR)
M106
MEN
M108
BDE HQ DEPUTY
M107
CORRIDOR
M100
SEC COM
M113
WOMEN
M109
ADOC COM
M114
UPS
M118
MECHANICAL
M117
ELECTRICAL
M116
CMD VTC CONF
M115
BREAK RM
M112
WELLNESS
M110
JAN
M111
MATCHLINE
/H1 FX104
EMERGENCY
POWER ROOM
M119
F
M4M6M8M9 M2 M1M10
MA
MB
MC
MD
ME
MF
M5 M3M7
A. REFER TO F-002 FOR LIST OF ABBREVIATIONS, SYMBOLS, AND GENERAL NOTES.
B. REFER TO SHEET FX501 THROUGH FX502 FOR FIRE SPRINKLER DETAILS.
C. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR COORDINATION
WITH LIGHTS, MECHANICAL DIFFUSERS, AND CEILING GRID.
GENERAL SHEET NOTES
SHEET KEYNOTES
PATTERN
FIRE SPRINKLER CRITERIA
ROOM/SPACE OCCUPANCY DENSITY/AREA
AND HOSE
LIGHT
HAZARD
0.10 GPM/SF OVER
MOST REMOTE 1,500
SF WITH 250 GPM
HOSE STREAM
ELECTRICAL/MECHANICAL
ROOMS, FILE ROOMS, JANITORS
ROOMS, TELEPHONE/DATA
ROOMS, RECEIVING,
PENTHOUSE,
AND STORAGE AREAS
0.2 GPM/SF OVER
MOST
REMOTE 2,500 SF
WITH 250 GPM HOSE
STREAM
OFFICE, CORRIDORS,
CLASSROOMS,
RESTROOMS, MEETING ROOMS,
LOBBIES, AND COMMON USE
AREAS
ORDINARY
HAZARD
NONE
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
B
IM
/U
S H
I_ D
U
S A
C E
M
D T
F
B u ild in g
/R
Y J B
L D
G D
M M
F .r v t
/1
/2
:2
:5
P
M
FX101
M
ID
D L E
W
IN
G
F
IR
E S
P R
IN
K
L E
R P
L A
N
H E
L E
M A
N O
M
IL
IT
A
R Y
R E
S E
R V
A T
IO
N
O
A H
U H
I
H O
N O
L U
L U
D
IS
T R
IC
T
B L D
G
R
O O
M
F
O R
T S
H A
F T
E R
H
I -5
J A
C O
B S
-A H
L J
V B
IS
H
O P
S T
S U
IT
E
H
O N
O L U
L U
H
I
J C
A M
P B
E L L
D N
G U
Y E
N
S Y
I
S B
A C
H T
E L H
E
IM
E R
M A
R C
H
W A
F
W A
-1 -D
-0
R T
A S
U B
M
IT
T A
L
F Y
M
D T
F
B
U
IL
D
IN
G
R Y
J
1/8" = 1'-0"A5
MIDDLE WING 1ST FLOOR FIRE SPRINKLER
PLAN
PLAN NORTH
C B A
MW EW
KEY PLAN
MAIN BUILDING
15 PROVIDE A SINGLE POINT OF ENTRY FOR THE PENETRATION ENTERING AND
LEAVING MECHANICAL M117 AND CMD VTC CONF M115. PENETRATIONS
THROUGH CONTROLLED BOUNDARY TO COMPLY WITH TEMPEST REQUIREMENTS.
51 PROVIDE A COMPLETE WET PIPE FIRE SUPPRESSION SYSTEM PER NFPA 13 AND
UFC 3-600-01 REQUIREMENTS FOR AREAS INSIDE BOUNDARY.
53 PROVIDE SEISMIC EXPANSION LOOP. RE: J15/FX501 FOR DETAIL.
62 DASHED LINE INDICATES THE CONTROLLED AREA PERIMETER. PIPE
PENETRATIONS THROUGH CONTROLLED AREA BOUNDARY TO COMPLY WITH
TEMPEST REQUIREMENETS. PROVIDE A SINGLE POINT OF ENTRY FOR PIPE
ENTERING AND LEAVING THE CONTROLLED AREA PERIMETER. PROVIDE
DIELECTRIC FITTINGS ON EACH SIDE OF THE CONTROLLED AREA BOUNDARY.
RE:A1/FX501 FOR DETAIL.
66 COORDINATE TELECOM CABINETS, UPS CABINETS, ELECTRICAL PANELS,
ELEVATOR EQUIPMENT, FIRE SPRINKLERS, AND FIRE SPRINKLER PIPING WITH
ELECTRICAL CONTRACTOR. FIRE SPRINKLERS AND FIRE SPRINKLER PIPING WILL
NOT BE LOCATED ABOVE ELECTRICAL PANELS, UPS CABINETS, ELEVATOR
EQUIPMENT, AND TELECOMM CABINETS.
67 PROVIDE TAMPER SWITCH, CHECK VALVE, AND FLOW SWITCH FOR UPS ROOM.
0 4' 8' 16'
ABC
STAIR
1G
SECURED VEST
E101
WELLNESS
E102
RESTROOM 1-A
E103
JAN
E104
TR
E114
UPS
E113
RESTROOM 1-B
E105
SHARED CONF
E106
MECH
E112
ELEC
E111
SPACE OFFICE
E110
SPACE TEAM
E109
HHD TEAM
E108
HHD OFFICE
E107
CORRIDOR 1
E100
MATCHLINE
/A1 FA104
F
E4
EA
EB
EC
ED
EE
E1E2E3
STAIR
2G
SECURED VEST
E201
BRIDGE
CORRIDOR
200D
SHARED CONF
E208
CEMA OFFICE
E207
RESTROOM 2-A
E202
RESTROOM 2-B
E203
CEMA TEAM
E204
MI OFFICE
E206
MI TEAM
E205A
MATCHLINE
/A1 FA104
F
JAN
E201A
E4
EA
EB
EC
ED
EE
E1E2E3
MI TEAM OPEN
OFFICE
E205B
CORRIDOR 2
E200
A. REFER TO F-002 FOR LIST OF ABBREVIATIONS, SYMBOLS, AND GENERAL NOTES.
B. REFER TO SHEET FX501 THROUGH FX502 FOR FIRE SPRINKLER DETAILS.
C. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR COORDINATION
WITH LIGHTS, MECHANICAL DIFFUSERS, AND CEILING GRID.
GENERAL SHEET NOTES
SHEET KEYNOTES
PATTERN
FIRE SPRINKLER CRITERIA
ROOM/SPACE OCCUPANCY DENSITY/AREA
AND HOSE
LIGHT
HAZARD
0.10 GPM/SF OVER
MOST REMOTE 1,500
SF WITH 250 GPM
HOSE STREAM
ELECTRICAL/MECHANICAL
ROOMS, FILE ROOMS, JANITORS
ROOMS, TELEPHONE/DATA
ROOMS, RECEIVING,
PENTHOUSE,
AND STORAGE AREAS
0.2 GPM/SF OVER
MOST
REMOTE 2,500 SF
WITH 250 GPM HOSE
STREAM
OFFICE, CORRIDORS,
CLASSROOMS,
RESTROOMS, MEETING ROOMS,
LOBBIES, AND COMMON USE
AREAS
ORDINARY
HAZARD
NONE
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
B
IM
/U
S H
I_ D
U
S A
C E
M
D T
F
B u ild in g
/R
Y J B
L D
G D
M M
F .r v t
/1
/2
:2
:5
P
M
FX102
E A
S T
W
IN
G
S
T
N
D F
L O
O R
F
IR
E S
P R
IN
K
L E
R P
L A
N
H E
L E
M A
N O
M
IL
IT
A
R Y
R E
S E
R V
A T
IO
N
O
A H
U H
I
H O
N O
L U
L U
D
IS
T R
IC
T
B L D
G
R
O O
M
F
O R
T S
H A
F T
E R
H
I -5
J A
C O
B S
-A H
L J
V B
IS
H
O P
S T
S U
IT
E
H
O N
O L U
L U
H
I
J C
A M
P B
E L L
D N
G U
Y E
N
S Y
I
S B
A C
H T
E L H
E
IM
E R
M A
R C
H
W A
F
W A
-1 -D
-0
R T
A S
U B
M
IT
T A
L
F Y
M
D T
F
B
U
IL
D
IN
G
R Y
J
1/8" = 1'-0"A11
EAST WING 1ST FLOOR FIRE SPRINKLER PLAN
1/8" = 1'-0"A4
EAST WING 2ND FLOOR FIRE SPRINKLER PLAN
51 PROVIDE A COMPLETE WET PIPE FIRE SUPPRESSION SYSTEM PER NFPA 13 AND
UFC 3-600-01 REQUIREMENTS FOR AREAS INSIDE BOUNDARY.
53 PROVIDE SEISMIC EXPANSION LOOP. RE: J15/FX501 FOR DETAIL.
59 4" SPRINKLER PIPE UP TO 2ND FLOOR.
60 4" SPRINKLER PIPE FROM 1ST FLOOR.
66 COORDINATE TELECOM CABINETS, UPS CABINETS, ELECTRICAL PANELS,
ELEVATOR EQUIPMENT, FIRE SPRINKLERS, AND FIRE SPRINKLER PIPING WITH
ELECTRICAL CONTRACTOR. FIRE SPRINKLERS AND FIRE SPRINKLER PIPING WILL
NOT BE LOCATED ABOVE ELECTRICAL PANELS, UPS CABINETS, ELEVATOR
EQUIPMENT, AND TELECOMM CABINETS.
67 PROVIDE TAMPER SWITCH, CHECK VALVE, AND FLOW SWITCH FOR UPS ROOM.
0 4' 8' 16'
PLAN NORTH
0 4' 8' 16'
C B A
MW EW
KEY PLAN
MAIN BUILDING
ABC
ABC
ABC
A. REFER TO F-002 FOR LIST OF ABBREVIATIONS, SYMBOLS, AND GENERAL NOTES.
B. REFER TO SHEET FX501 THROUGH FX502 FOR FIRE SPRINKLER DETAILS.
C. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR COORDINATION
WITH LIGHTS, MECHANICAL DIFFUSERS, AND CEILING GRID.
GENERAL SHEET NOTES
SHEET KEYNOTES
F15
FX502
F15
FX502
15C15D16171819202122
D
E
F
D.7
CHAPLAIN
B102
ASSIST.
CHAPLAIN
B103
STORAGE 4
B104
LARGE
CONFERENCE
B101
MECH
B122
STORAGE 5
B121
FP
B105
ARMS RM
B120
CORRIDOR
B117A
ARMS RM
B119 ARMS RM
B118
TR-0
B114
STORAGE 1
B113
CORRIDOR
B117B
ELEC CLOSET
B111
WATER HEATER
B109
ARMS RM
B115
JAN
B108
WOMEN
B107
MEN
B106
PATTERN
FIRE SPRINKLER CRITERIA
ROOM/SPACE OCCUPANCY DENSITY/AREA
AND HOSE
LIGHT
HAZARD
0.10 GPM/SF OVER
MOST REMOTE 1,500
SF WITH 250 GPM
HOSE STREAM
ELECTRICAL/MECHANICAL
ROOMS, FILE ROOMS, JANITORS
ROOMS, TELEPHONE/DATA
ROOMS, RECEIVING,
PENTHOUSE,
AND STORAGE AREAS
0.2 GPM/SF OVER
MOST
REMOTE 2,500 SF
WITH 250 GPM HOSE
STREAM
OFFICE, CORRIDORS,
CLASSROOMS,
RESTROOMS, MEETING ROOMS,
LOBBIES, AND COMMON USE
AREAS
ORDINARY
HAZARD
NONE
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
B
IM
/U
S H
I_ D
U
S A
C E
M
D T
F
B u ild in g
/R
Y J B
L D
G D
M M
F .r v t
/1
/2
:2
:5
P
M
FX103
M A
IN
B
U
IL
D
IN
G
B A
S E
M E
N T
F
IR
E S
P R
IN
K
L E
R P
L A
N
H E
L E
M A
N O
M
IL
IT
A
R Y
R E
S E
R V
A T
IO
N
O
A H
U H
I
H O
N O
L U
L U
D
IS
T R
IC
T
B L D
G
R
O O
M
F
O R
T S
H A
F T
E R
H
I -5
J A
C O
B S
-A H
L J
V B
IS
H
O P
S T
S U
IT
E
H
O N
O L U
L U
H
I
J C
A M
P B
E L L
D N
G U
Y E
N
S Y
I
S B
A C
H T
E L H
E
IM
E R
M A
R C
H
W A
F
W A
-1 -D
-0
R T
A S
U B
M
IT
T A
L
F Y
M
D T
F
B
U
IL
D
IN
G
R Y
J
51 PROVIDE A COMPLETE WET PIPE FIRE SUPPRESSION SYSTEM PER NFPA 13 AND
UFC 3-600-01 REQUIREMENTS FOR AREAS INSIDE BOUNDARY.
52 NEW 6" SPRINKLER RISER SERVING BUILDING 300. RE: F9/FX501 FOR DETAIL.
54 8" FIRE MAIN. RE: B1/CU102 FOR CONTINUATION.
61 FLOOR CONTROL VALVE ASSEMBLY. RE:F2/FX501 FOR DETAIL.
66 COORDINATE TELECOM CABINETS, UPS CABINETS, ELECTRICAL PANELS,
ELEVATOR EQUIPMENT, FIRE SPRINKLERS, AND FIRE SPRINKLER PIPING WITH
ELECTRICAL CONTRACTOR. FIRE SPRINKLERS AND FIRE SPRINKLER PIPING WILL
NOT BE LOCATED ABOVE ELECTRICAL PANELS, UPS CABINETS, ELEVATOR
EQUIPMENT, AND TELECOMM CABINETS.
0 4' 8' 16'
PLAN NORTH
C B A
MW EW
KEY PLAN
MAIN BUILDING
1/8" = 1'-0"A1
BASEMENT FIRE SPRINKLER PLAN - SECTION C
DN
ABC
A B
C
ABC
ABC
A. REFER TO F-002 FOR LIST OF ABBREVIATIONS, SYMBOLS, AND GENERAL NOTES.
B. REFER TO SHEET FX501 THROUGH FX502 FOR FIRE SPRINKLER DETAILS.
C. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR COORDINATION
WITH LIGHTS, MECHANICAL DIFFUSERS, AND CEILING GRID.
GENERAL SHEET NOTES
SHEET KEYNOTES
BDE S1
CMD STOR
PLATOON
TRAINING
1ST SGT
XO
CO
CONFERENCE
ROOM
SECURE
STORAGE
UNIT STORAGE
NBC STOR
COMM STOR
S6 / INTWRK
STORAGE
S6
S6 OFFICE
TGT DEV
ELEMENT
WATER HEATER
JAN
CORRIDOR
100A
WOMEN
MECH 1-B
168TR-1B
CYBERSEC
S4
ELEC
MEN
M A
T C
H L
IN
E
H
F
X
MATCHLINE
/A11 FX102
7 6 5 4 3 2 18
D
E
F
D.7
LOBBY
ELEV
EL-1
STAIR
1D
TR-1A
STAIR
1F
STORAGE
ARMS RM
ARMS RM
STAFF SECT
STORAGE
ELEC
SHARED CONF
BREAKROOM
WELLNESS
EXIT LOBBY
STAIR
1C
SJA
SJA OFFICE
CORRIDOR
100B
MATCHLINE
M A
T C
H L
IN
E
M A
T C
H L
IN
E
A
F
X
A
F
X
/A5 FX101
89A9B101112131415C15D
D
E
F
D.7
08 09
ELEVATOR
MACHINE ROOM
STAIR
1E
PATTERN
FIRE SPRINKLER CRITERIA
ROOM/SPACE OCCUPANCY DENSITY/AREA
AND HOSE
LIGHT
HAZARD
0.10 GPM/SF OVER
MOST REMOTE 1,500
SF WITH 250 GPM
HOSE STREAM
ELECTRICAL/MECHANICAL
ROOMS, FILE ROOMS, JANITORS
ROOMS, TELEPHONE/DATA
ROOMS, RECEIVING,
PENTHOUSE,
AND STORAGE AREAS
0.2 GPM/SF OVER
MOST
REMOTE 2,500 SF
WITH 250 GPM HOSE
STREAM
OFFICE, CORRIDORS,
CLASSROOMS,
RESTROOMS, MEETING ROOMS,
LOBBIES, AND COMMON USE
AREAS
ORDINARY
HAZARD
NONE
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
B
IM
/U
S H
I_ D
U
S A
C E
M
D T
F
B u ild in g
/R
Y J B
L D
G D
M M
F .r v t
/1
/2
:2
:5
P
M
FX104
M A
IN
B
U
IL
D
IN
G
S
T F
L O
O R
F
IR
E S
P R
IN
K
L E
R P
L A
N
H E
L E
M A
N O
M
IL
IT
A
R Y
R E
S E
R V
A T
IO
N
O
A H
U H
I
H O
N O
L U
L U
D
IS
T R
IC
T
B L D
G
R
O O
M
F
O R
T S
H A
F T
E R
H
I -5
J A
C O
B S
-A H
L J
V B
IS
H
O P
S T
S U
IT
E
H
O N
O L U
L U
H
I
J C
A M
P B
E L L
D N
G U
Y E
N
S Y
I
S B
A C
H T
E L H
E
IM
E R
M A
R C
H
W A
F
W A
-1 -D
-0
R T
A S
U B
M
IT
T A
L
F Y
M
D T
F
B
U
IL
D
IN
G
R Y
J
08 TAMPER SWITCH FOR ELEVATOR PIT. RE: H1/FA501 FOR DETAIL.
09 TAMPER AND FLOW SWITCH (ZERO DELAY) FOR ELEVATOR MACHINE ROOM. RE:
H1/FA501 FOR DETAIL.
51 PROVIDE A COMPLETE WET PIPE FIRE SUPPRESSION SYSTEM PER NFPA 13 AND
UFC 3-600-01 REQUIREMENTS FOR AREAS INSIDE BOUNDARY.
53 PROVIDE SEISMIC EXPANSION LOOP. RE: J15/FX501 FOR DETAIL.
63 4" SPRINKLER PIPE TO MIDDLE WING.
64 4" SPRINKLER PIPE TO EAST WING.
66 COORDINATE TELECOM CABINETS, UPS CABINETS, ELECTRICAL PANELS,
ELEVATOR EQUIPMENT, FIRE SPRINKLERS, AND FIRE SPRINKLER PIPING WITH
ELECTRICAL CONTRACTOR. FIRE SPRINKLERS AND FIRE SPRINKLER PIPING WILL
NOT BE LOCATED ABOVE ELECTRICAL PANELS, UPS CABINETS, ELEVATOR
EQUIPMENT, AND TELECOMM CABINETS.
1/8" = 1'-0"A1
MAIN BUILDING 1ST FLOOR FIRE SPRINKLER
PLAN - SECTION A
1/8" = 1'-0"H1
MAIN BUILDING 1ST FLOOR FIRE SPRINKLER
PLAN - SECTION B
0 4' 8' 16'
PLAN NORTH
C B A
MW EW
KEY PLAN
ABC ABCABC
A. REFER TO F-002 FOR LIST OF ABBREVIATIONS, SYMBOLS, AND GENERAL NOTES.
B. REFER TO SHEET FX501 THROUGH FX502 FOR FIRE SPRINKLER DETAILS.
C. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR COORDINATION
WITH LIGHTS, MECHANICAL DIFFUSERS, AND CEILING GRID.
GENERAL SHEET NOTES
SHEET KEYNOTES
CBRN 1
CBRN 2
COMP LAB
MEETING ROOM 2
MEETING ROOM 1
TRAINING
137 TRAINING
ELEC
SUPPLY
SUPPLY
CBRN
FP
RETENTION
MECH-1A
141 WOMEN
JAN
XO
XO
MEN
CO STOR
TOILET
CO
CO
ORDERLY
TOILET
ORDERLY
1ST SGT
1ST SGT
M A
T C
H L
IN
E
H
F
X
F15
FX502
F15
FX502
15C15D16171819202122
D
E
F
D.7
PATTERN
FIRE SPRINKLER CRITERIA
ROOM/SPACE OCCUPANCY DENSITY/AREA
AND HOSE
LIGHT
HAZARD
0.10 GPM/SF OVER
MOST REMOTE 1,500
SF WITH 250 GPM
HOSE STREAM
ELECTRICAL/MECHANICAL
ROOMS, FILE ROOMS, JANITORS
ROOMS, TELEPHONE/DATA
ROOMS, RECEIVING,
PENTHOUSE,
AND STORAGE AREAS
0.2 GPM/SF OVER
MOST
REMOTE 2,500 SF
WITH 250 GPM HOSE
STREAM
OFFICE, CORRIDORS,
CLASSROOMS,
RESTROOMS, MEETING ROOMS,
LOBBIES, AND COMMON USE
AREAS
ORDINARY
HAZARD
NONE
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
B
IM
/U
S H
I_ D
U
S A
C E
M
D T
F
B u ild in g
/R
Y J B
L D
G D
M M
F .r v t
/1
/2
:2
:5
P
M
FX105
M A
IN
B
U
IL
D
IN
G
S
T F
L O
O R
F
IR
E S
P R
IN
K
L E
R P
L A
N
H E
L E
M A
N O
M
IL
IT
A
R Y
R E
S E
R V
A T
IO
N
O
A H
U H
I
H O
N O
L U
L U
D
IS
T R
IC
T
B L D
G
R
O O
M
F
O R
T S
H A
F T
E R
H
I -5
J A
C O
B S
-A H
L J
V B
IS
H
O P
S T
S U
IT
E
H
O N
O L U
L U
H
I
J C
A M
P B
E L L
D N
G U
Y E
N
S Y
I
S B
A C
H T
E L H
E
IM
E R
M A
R C
H
W A
F
W A
-1 -D
-0
R T
A S
U B
M
IT
T A
L
F Y
M
D T
F
B
U
IL
D
IN
G
R Y
J
51 PROVIDE A COMPLETE WET PIPE FIRE SUPPRESSION SYSTEM PER NFPA 13 AND
UFC 3-600-01 REQUIREMENTS FOR AREAS INSIDE BOUNDARY.
55 6" SPRINKLER RISER FROM BASEMENT.
61 FLOOR CONTROL VALVE ASSEMBLY. RE:F2/FX501 FOR DETAIL.
66 COORDINATE TELECOM CABINETS, UPS CABINETS, ELECTRICAL PANELS,
ELEVATOR EQUIPMENT, FIRE SPRINKLERS, AND FIRE SPRINKLER PIPING WITH
ELECTRICAL CONTRACTOR. FIRE SPRINKLERS AND FIRE SPRINKLER PIPING WILL
NOT BE LOCATED ABOVE ELECTRICAL PANELS, UPS CABINETS, ELEVATOR
EQUIPMENT, AND TELECOMM CABINETS.
1/8" = 1'-0"A1
MAIN BUILDING 1ST FLOOR FIRE SPRINKLER
PLAN - SECTION C
0 4' 8' 16'
PLAN NORTH
C B A
MW EW
ABCABC
ABCABC ABC
A. REFER TO F-002 FOR LIST OF ABBREVIATIONS, SYMBOLS, AND GENERAL NOTES.
B. REFER TO SHEET FX501 THROUGH FX502 FOR FIRE SPRINKLER DETAILS.
C. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR COORDINATION
WITH LIGHTS, MECHANICAL DIFFUSERS, AND CEILING GRID.
GENERAL SHEET NOTES
SHEET KEYNOTES
TRAINING
S2 CUOPS (INTEL
OPS)
INTEL FUOPS
TR-2B
ELEC
MECH-2B
WOMEN
MEN
STORAGE
JAN
BDE CMD GROUP
BDE CMD OFFICE
BDE CMD OFFICE
BDE CMD OFFICE
INTEL GEOINT
BDE CDR CONF
RM
BDE S2 (INTEL
HQ)
CORRIDOR
200A
BRIDGE
CORRIDOR
200D
M A
T C
H L
IN
E
H
F
X
MATCHLINE
/A4 FX102
SIPR CAFE
7 6 5 4 3 2 18
D
E
F
D.7
STAIR
2D
LOBBY
ELEV
EL-2
TR-2A
WELLNESS
EXP/VISIT SPACE
ELEC
PLATOON
SHARED CONF
(S2)
TRAINING
1ST SGT
XO
CO
CONFERENCE
UNIT STORAGE
COMM STOR
NBC STOR
STAIR
2C
CMD STOR
SECURE STOR
M A
T C
H L
IN
E
M A
T C
H L
IN
E
A
F
X
A
F
X
SHARED CONF
(S2)
TRAINING
89A9B101112131415C15D
D
E
F
D.7
PATTERN
FIRE SPRINKLER CRITERIA
ROOM/SPACE OCCUPANCY DENSITY/AREA
AND HOSE
LIGHT
HAZARD
0.10 GPM/SF OVER
MOST REMOTE 1,500
SF WITH 250 GPM
HOSE STREAM
ELECTRICAL/MECHANICAL
ROOMS, FILE ROOMS, JANITORS
ROOMS, TELEPHONE/DATA
ROOMS, RECEIVING,
PENTHOUSE,
AND STORAGE AREAS
0.2 GPM/SF OVER
MOST
REMOTE 2,500 SF
WITH 250 GPM HOSE
STREAM
OFFICE, CORRIDORS,
CLASSROOMS,
RESTROOMS, MEETING ROOMS,
LOBBIES, AND COMMON USE
AREAS
ORDINARY
HAZARD
NONE
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
B
IM
/U
S H
I_ D
U
S A
C E
M
D T
F
B u ild in g
/R
Y J B
L D
G D
M M
F .r v t
/1
/2
:2
:5
P
M
FX106
M A
IN
B
U
IL
D
IN
G
N
D F
L O
O R
F
IR
E S
P R
IN
K
L E
R P
L A
N
H E
L E
M A
N O
M
IL
IT
A
R Y
R E
S E
R V
A T
IO
N
O
A H
U H
I
H O
N O
L U
L U
D
IS
T R
IC
T
B L D
G
R
O O
M
F
O R
T S
H A
F T
E R
H
I -5
J A
C O
B S
-A H
L J
V B
IS
H
O P
S T
S U
IT
E
H
O N
O L U
L U
H
I
J C
A M
P B
E L L
D N
G U
Y E
N
S Y
I
S B
A C
H T
E L H
E
IM
E R
M A
R C
H
W A
F
W A
-1 -D
-0
R T
A S
U B
M
IT
T A
L
F Y
M
D T
F
B
U
IL
D
IN
G
R Y
J
51 PROVIDE A COMPLETE WET PIPE FIRE SUPPRESSION SYSTEM PER NFPA 13 AND
UFC 3-600-01 REQUIREMENTS FOR AREAS INSIDE BOUNDARY.
53 PROVIDE SEISMIC EXPANSION LOOP. RE: J15/FX501 FOR DETAIL.
66 COORDINATE TELECOM CABINETS, UPS CABINETS, ELECTRICAL PANELS,
ELEVATOR EQUIPMENT, FIRE SPRINKLERS, AND FIRE SPRINKLER PIPING WITH
ELECTRICAL CONTRACTOR. FIRE SPRINKLERS AND FIRE SPRINKLER PIPING WILL
NOT BE LOCATED ABOVE ELECTRICAL PANELS, UPS CABINETS, ELEVATOR
EQUIPMENT, AND TELECOMM CABINETS.
1/8" = 1'-0"A1
MAIN BUILDING 2ND FLOOR FIRE SPRINKLER
PLAN - SECTION A
1/8" = 1'-0"H1
MAIN BUILDING 2ND FLOOR FIRE SPRINKLER
PLAN - SECTION B
0 4' 8' 16'
PLAN NORTH
C B A
MW EW
KEY PLAN
ABC ABC
A. REFER TO F-002 FOR LIST OF ABBREVIATIONS, SYMBOLS, AND GENERAL NOTES.
B. REFER TO SHEET FX501 THROUGH FX502 FOR FIRE SPRINKLER DETAILS.
C. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR COORDINATION
WITH LIGHTS, MECHANICAL DIFFUSERS, AND CEILING GRID.
GENERAL SHEET NOTES
SHEET KEYNOTES
STORAGE
STORAGE
STORAGE
STORAGE
S1 SHOP
NCOIC
OIC
S4 OIC
NCOIC
S4 SHOP
RESTROOM
HHC STOR
HHC STOR
HHC XO
HHC SUPPLY
PBO
MEN
WOMEN
JAN
MECH-2A
FP
1SG
ORDERLY
ORDERLY
HHC CO
HHC CONF
M A
T C
H L
IN
E M
A T
C H
L
IN
E
H
F
X
F15
FX502
F15
FX502
15C15D16171819202122
D
E
F
D.7
ELEC
PATTERN
FIRE SPRINKLER CRITERIA
ROOM/SPACE OCCUPANCY DENSITY/AREA
AND HOSE
LIGHT
HAZARD
0.10 GPM/SF OVER
MOST REMOTE 1,500
SF WITH 250 GPM
HOSE STREAM
ELECTRICAL/MECHANICAL
ROOMS, FILE ROOMS, JANITORS
ROOMS, TELEPHONE/DATA
ROOMS, RECEIVING,
PENTHOUSE,
AND STORAGE AREAS
0.2 GPM/SF OVER
MOST
REMOTE 2,500 SF
WITH 250 GPM HOSE
STREAM
OFFICE, CORRIDORS,
CLASSROOMS,
RESTROOMS, MEETING ROOMS,
LOBBIES, AND COMMON USE
AREAS
ORDINARY
HAZARD
NONE
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
B
IM
/U
S H
I_ D
U
S A
C E
M
D T
F
B u ild in g
/R
Y J B
L D
G D
M M
F .r v t
/1
/2
:2
:5
P
M
FX107
M A
IN
B
U
IL
D
IN
G
N
D F
L O
O R
F
IR
E S
P R
IN
K
L E
R P
L A
N
H E
L E
M A
N O
M
IL
IT
A
R Y
R E
S E
R V
A T
IO
N
O
A H
U H
I
H O
N O
L U
L U
D
IS
T R
IC
T
B L D
G
R
O O
M
F
O R
T S
H A
F T
E R
H
I -5
J A
C O
B S
-A H
L J
V B
IS
H
O P
S T
S U
IT
E
H
O N
O L U
L U
H
I
J C
A M
P B
E L L
D N
G U
Y E
N
S Y
I
S B
A C
H T
E L H
E
IM
E R
M A
R C
H
W A
F
W A
-1 -D
-0
R T
A S
U B
M
IT
T A
L
F Y
M
D T
F
B
U
IL
D
IN
G
R Y
J
51 PROVIDE A COMPLETE WET PIPE FIRE SUPPRESSION SYSTEM PER NFPA 13 AND
UFC 3-600-01 REQUIREMENTS FOR AREAS INSIDE BOUNDARY.
61 FLOOR CONTROL VALVE ASSEMBLY. RE:F2/FX501 FOR DETAIL.
65 6" SPRINKLER RISER FROM 1ST FLOOR.
66 COORDINATE TELECOM CABINETS, UPS CABINETS, ELECTRICAL PANELS,
ELEVATOR EQUIPMENT, FIRE SPRINKLERS, AND FIRE SPRINKLER PIPING WITH
ELECTRICAL CONTRACTOR. FIRE SPRINKLERS AND FIRE SPRINKLER PIPING WILL
NOT BE LOCATED ABOVE ELECTRICAL PANELS, UPS CABINETS, ELEVATOR
EQUIPMENT, AND TELECOMM CABINETS.
1/8" = 1'-0"A1
MAIN BUILDING 2ND FLOOR FIRE SPRINKLER
PLAN - SECTION C
0 4' 8' 16'
PLAN NORTH
C B A
MW EW
ABC
ABC
ABC
A. REFER TO F-002 FOR LIST OF ABBREVIATIONS, SYMBOLS, AND GENERAL NOTES.
B. REFER TO SHEET FX501 THROUGH FX502 FOR FIRE SPRINKLER DETAILS.
C. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR COORDINATION
WITH LIGHTS, MECHANICAL DIFFUSERS, AND CEILING GRID.
GENERAL SHEET NOTES
SHEET KEYNOTES
FIRES CONTROL
ELEMENT
CORRIDOR
300A
FIRES LETHAL
EFFECTS
ELEMENT
DODIN CONTENT
FIRES CELL HQ
FIRES CELL HQ
AMD CELL
DODIN
ENTERPRISE
STORAGE
TAC CURR OPS
JAN
MEN
WOMEN
AUG TDA OFFICE
AUG TDA OFFICE
AUG TDA OFFICE
AUG TDA OFFICE
SPECIAL STAFF
(AUG TDA)
MECH-3B
357TR-3B
ELEC
UNIT STORAGE
M A
T C
H L
IN
E
H
F
X
7 6 5 4 3 2 18
D
E
F
D.7
BDE S3
STAIR
3D
LOBBY
ELEV
EL-3
ELEC
SHARED CONF
(S3)
SECURE
STORAGE
313 STAIR
3C
TR-3A
WELLNESS
EXP/VISIT SPACE
PLATOON
TRAINING
1ST SGT
XO
348 CO
CONFERENCE
CMD STOR
NBC STORAGE
51M A
T C
H L
IN
E
M A
T C
H L
IN
E
A
F
X
A
F
X
UNIT STORAGE
COMM STOR
89A9B101112131415C15D
D
E
F
D.7
BDE S3 OFFICE
BDE S3
PATTERN
FIRE SPRINKLER CRITERIA
ROOM/SPACE OCCUPANCY DENSITY/AREA
AND HOSE
LIGHT
HAZARD
0.10 GPM/SF OVER
MOST REMOTE 1,500
SF WITH 250 GPM
HOSE STREAM
ELECTRICAL/MECHANICAL
ROOMS, FILE ROOMS, JANITORS
ROOMS, TELEPHONE/DATA
ROOMS, RECEIVING,
PENTHOUSE,
AND STORAGE AREAS
0.2 GPM/SF OVER
MOST
REMOTE 2,500 SF
WITH 250 GPM HOSE
STREAM
OFFICE, CORRIDORS,
CLASSROOMS,
RESTROOMS, MEETING ROOMS,
LOBBIES, AND COMMON USE
AREAS
ORDINARY
HAZARD
NONE
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
B
IM
/U
S H
I_ D
U
S A
C E
M
D T
F
B u ild in g
/R
Y J B
L D
G D
M M
F .r v t
/1
/2
:2
:5
P
M
FX108
M A
IN
B
U
IL
D
IN
G
R
D F
L O
O R
F
IR
E S
P R
IN
K
L E
R P
L A
N
H E
L E
M A
N O
M
IL
IT
A
R Y
R E
S E
R V
A T
IO
N
O
A H
U H
I
H O
N O
L U
L U
D
IS
T R
IC
T
B L D
G
R
O O
M
F
O R
T S
H A
F T
E R
H
I -5
J A
C O
B S
-A H
L J
V B
IS
H
O P
S T
S U
IT
E
H
O N
O L U
L U
H
I
J C
A M
P B
E L L
D N
G U
Y E
N
S Y
I
S B
A C
H T
E L H
E
IM
E R
M A
R C
H
W A
F
W A
-1 -D
-0
R T
A S
U B
M
IT
T A
L
F Y
M
D T
F
B
U
IL
D
IN
G
R Y
J
51 PROVIDE A COMPLETE WET PIPE FIRE SUPPRESSION SYSTEM PER NFPA 13 AND
UFC 3-600-01 REQUIREMENTS FOR AREAS INSIDE BOUNDARY.
53 PROVIDE SEISMIC EXPANSION LOOP. RE: J15/FX501 FOR DETAIL.
66 COORDINATE TELECOM CABINETS, UPS CABINETS, ELECTRICAL PANELS,
ELEVATOR EQUIPMENT, FIRE SPRINKLERS, AND FIRE SPRINKLER PIPING WITH
ELECTRICAL CONTRACTOR. FIRE SPRINKLERS AND FIRE SPRINKLER PIPING WILL
NOT BE LOCATED ABOVE ELECTRICAL PANELS, UPS CABINETS, ELEVATOR
EQUIPMENT, AND TELECOMM CABINETS.
1/8" = 1'-0"A1
MAIN BUILDING 3RD FLOOR FIRE SPRINKLER
PLAN - SECTION A
1/8" = 1'-0"H1
MAIN BUILDING 3RD FLOOR FIRE SPRINKLER
PLAN - SECTION B
0 4' 8' 16'
PLAN NORTH
C B A
MW EW
KEY PLAN
A. REFER TO F-002 FOR LIST OF ABBREVIATIONS, SYMBOLS, AND GENERAL NOTES.
B. REFER TO SHEET FX501 THROUGH FX502 FOR FIRE SPRINKLER DETAILS.
C. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR COORDINATION
WITH LIGHTS, MECHANICAL DIFFUSERS, AND CEILING GRID.
GENERAL SHEET NOTES
SHEET KEYNOTES
IMO SHOP
NCOIC
OIC
S3 SHOP
S3 SHOP
OIC
NCOIC
BC
TOILET
TOILET
CSM
DRIVER
S2
XO
MEN
WOMEN
JAN
MECH-3A
335FP
COMSEC VAULT
SIPR CAFE
NET OPS
NET OPS
CORRIDOR
300C
51 M A
T C
H L
IN
E
H
F
X
F15
FX502
F15
FX502
15C15D16171819202122
D
E
F
D.7
ELEC
PATTERN
FIRE SPRINKLER CRITERIA
ROOM/SPACE OCCUPANCY DENSITY/AREA
AND HOSE
LIGHT
HAZARD
0.10 GPM/SF OVER
MOST REMOTE 1,500
SF WITH 250 GPM
HOSE STREAM
ELECTRICAL/MECHANICAL
ROOMS, FILE ROOMS, JANITORS
ROOMS, TELEPHONE/DATA
ROOMS, RECEIVING,
PENTHOUSE,
AND STORAGE AREAS
0.2 GPM/SF OVER
MOST
REMOTE 2,500 SF
WITH 250 GPM HOSE
STREAM
OFFICE, CORRIDORS,
CLASSROOMS,
RESTROOMS, MEETING ROOMS,
LOBBIES, AND COMMON USE
AREAS
ORDINARY
HAZARD
NONE
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
B
IM
/U
S H
I_ D
U
S A
C E
M
D T
F
B u ild in g
/R
Y J B
L D
G D
M M
F .r v t
/1
/2
:2
:5
P
M
FX109
M A
IN
B
U
IL
D
IN
G
R
D F
L O
O R
F
IR
E S
P R
IN
K
L E
R P
L A
N
H E
L E
M A
N O
M
IL
IT
A
R Y
R E
S E
R V
A T
IO
N
O
A H
U H
I
H O
N O
L U
L U
D
IS
T R
IC
T
B L D
G
R
O O
M
F
O R
T S
H A
F T
E R
H
I -5
J A
C O
B S
-A H
L J
V B
IS
H
O P
S T
S U
IT
E
H
O N
O L U
L U
H
I
J C
A M
P B
E L L
D N
G U
Y E
N
S Y
I
S B
A C
H T
E L H
E
IM
E R
M A
R C
H
W A
F
W A
-1 -D
-0
R T
A S
U B
M
IT
T A
L
F Y
M
D T
F
B
U
IL
D
IN
G
R Y
J
51 PROVIDE A COMPLETE WET PIPE FIRE SUPPRESSION SYSTEM PER NFPA 13 AND
UFC 3-600-01 REQUIREMENTS FOR AREAS INSIDE BOUNDARY.
56 6" SPRINKLER RISER FROM 2ND FLOOR.
62 DASHED LINE INDICATES THE CONTROLLED AREA PERIMETER. PIPE
PENETRATIONS THROUGH CONTROLLED AREA BOUNDARY TO COMPLY WITH
TEMPEST REQUIREMENETS. PROVIDE A SINGLE POINT OF ENTRY FOR PIPE
ENTERING AND LEAVING THE CONTROLLED AREA PERIMETER. PROVIDE
DIELECTRIC FITTINGS ON EACH SIDE OF THE CONTROLLED AREA BOUNDARY.
RE:A1/FX501 FOR DETAIL.
66 COORDINATE TELECOM CABINETS, UPS CABINETS, ELECTRICAL PANELS,
ELEVATOR EQUIPMENT, FIRE SPRINKLERS, AND FIRE SPRINKLER PIPING WITH
ELECTRICAL CONTRACTOR. FIRE SPRINKLERS AND FIRE SPRINKLER PIPING WILL
NOT BE LOCATED ABOVE ELECTRICAL PANELS, UPS CABINETS, ELEVATOR
EQUIPMENT, AND TELECOMM CABINETS.
1/8" = 1'-0"A1
MAIN BUILDING 3RD FLOOR FIRE SPRINKLER
PLAN - SECTION C
0 4' 8' 16'
PLAN NORTH
C B A
MW EW
STEEL PIPE X CPVC
ADAPTER
STEEL
SPRINKLER
PIPING
WALL OF CLASSIFIED
BOUNDARY
UL/FM APPROVED CPVC
SPRINKLER PIPE
STEEL SPRINKLER
PIPIING
6" MAX
HIGHER SECURITY
LEVEL AREA
LOWER SECURITY
LEVEL AREA
1" - 2" PIPE
FULL FACE INSULATING
FLANGE GASKET
DI-ELECTRIC FLANGED
UNION
WALL OF CLASSIFIED
BOUNDARY
LOWER SECURITY
LEVEL AREA
3" AND GREATER PIPE
HIGHER SECURITY
LEVEL AREA
6" MAX
NON-METALLIC FLAT
WASHER
BOLTS TO BE INSTALLED
WITH NON-METALLIC
SLEEVES AND WASHERS
ANCILLARY CONSTRUCTION PRODUCTS
COMING INTO CONTACT WITH CPVC PIPE
MUST BE CHEMICALLY COMPATIBLE.
PROVIDE FIRE STOPPING CAULK IN FIRE
RATED WALLS OR PLASTIC WATERPROOF
CEMENT IN NON-FIRE RATED WALLS (TYP.)
CONDUCTIVE TAPE
AROUND PIPING
PENETRATION
CONDUCTIVE TAPE
AROUND PIPING
PENETRATION
SURFACE MOUNTED FIRE
EXTINGUISHER CABINET
WITH FIRE EXTINGUISHER
WALL
FINISHED
FLOOR
F
E E
T M
A X
WALL
FINISHED
FLOOR
CABINET MOUNTED BRACKET MOUNTED
SIDE VIEW FRONT VIEW SIDE VIEW FRONT VIEW
F
E E
T M
A X
FIRE EXTINGUISHER
FLUSH MOUNTED FDC HEADER, 6" F NPT X 2.5" X
2.5" F SWIVEL NST CLAPPERED SNOOTS, WITH
FEMALE NPT BACK OUTLET
B
B
30" AFG
BRASS COVER PLATE
SECTION C-C
15"
A
FINISHED
GRADE
A
6"
PROVIDE RESTRAINED JOINT
SYSTEM IN ACCORDANCE WITH
NFPA 24
SECTION D-D
6" CHECK VALVE
FLUSH MOUNTED TEST HEADER, 6" F NPT X
2.5" X 2.5" X 2.5" X 2.5" M NST GATE VALVES
AND 2.5" CAPS, WITH GROOVE BACK INLET
C
C
30" AFG
SECTION B-B
30"
9"
D
FINISHED GRADE
D
SECTION A-A
6" OS&Y VALVE WITH
LOCK AND CHAIN
FOUR 2.5" TEST HEADER
VALVES PROVIDE CHAIN AND
PADLOCK FOR ALL VALVES
2-WAY FIRE DEPT.
CONN. W/ CLAPPER
TYPE CONNECTION
CONCRETE MONUMENT
FOR FDC AND BFP TEST
HEADER WITH
REINFORCING. SEE S-508
6"
28" 28"
PROVIDE RESTRAINED JOINT
SYSTEM IN ACCORDANCE WITH
NFPA 24
FOUR 2.5" TEST HEADER
VALVES PROVIDE CHAIN AND
PADLOCK FOR ALL VALVES
NOTES:
1. FIRE PROTECTION FDC AND TEST HEADERS REQUIREMENTS MUST BE
IN ACCORDANCE WITH SECTIONS 22 13 13 WET PIPE SPRINKLER
SYSTEMS, FIRE PROTECTION.
6"
PROVIDE RESTRAINED JOINT
SYSTEM IN ACCORDANCE WITH
NFPA 24
CONCRETE MONUMENT
FOR FDC AND BFP TEST
HEADER WITH
REINFORCING. SEE S-508
MINIMUM 36"MINIMUM 36"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
B
IM
/U
S H
I_ D
U
S A
C E
M
D T
F
B u ild in g
/R
Y J B
L D
G D
M M
F .r v t
/1
/2
:2
:5
P
M
FX501
F
IR
E S
P R
IN
K
L E
R D
E T
A
IL
S
H E
L E
M A
N O
M
IL
IT
A
R Y
R E
S E
R V
A T
IO
N
O
A H
U H
I
H O
N O
L U
L U
D
IS
T R
IC
T
B L D
G
R
O O
M
F
O R
T S
H A
F T
E R
H
I -5
J A
C O
B S
-A H
L J
V B
IS
H
O P
S T
S U
IT
E
H
O N
O L U
L U
H
I
J C
A M
P B
E L L
D N
G U
Y E
N
S Y
I
S B
A C
H T
E L H
E
IM
E R
M A
R C
H
W A
F
W A
-1 -D
-0
R T
A S
U B
M
IT
T A
L
F Y
M
D T
F
B
U
IL
D
IN
G
R Y
J
NTSA1
CLASSIFIED AREA PIPE PENETRATIONS
DETAILS
NTSA6
FIRE EXTINGUISHER MOUNTING DETAIL
NTSH1
FDC/TEST HEADER AND MONUMENT DETAIL
FINISHED FLOOR
PROVIDE SPLASHBLOCK AS
NECESSARY
1" GLOBE VALVE OR
TEST DRAIN ASSEMBLY
1" PIPE FROM END OF
REMOTE BRANCH
LINE
45° ELBOW WITH CORROSION
RESISTANT OUTLET EQUAL TO
ONE SPRINKLER. 2 FT A.F.F.
CONNECTION
F
IR
E S
P R
IN
K
L E
R R
IS
E
R
TO EXPRESS DRAIN TEST AND DRAIN VALVE AND
1/2" ORIFICE
TO
SYSTEM
PRESSURE GUAGE
FLOW SWITCH
CHECK VALVE (PER UFC
REQUIREMENTS)
OS&Y VALVE WITH TAMPER
SWITCH
SPLASHBLOCK
MAIN DRAIN PIPED TO
OUTSIDE 2 FEET A.F.F.
FLOW SWITCH
WEATHERPROOF
HORN/STROBE
6" SUPPLY TO BASEMENT, LEVEL 1, LEVEL 2,
AND LEVEL 3 SPRINKLER SYSTEMS OFFSET
VERTICAL RISER PIPING AS NECESSARY TO
AVOID MECHANICAL DUCTWORK AND PIPING
ABOVE.
OS&Y VALVE WITH
TAMPER SWITCH (TYP)
3" MAIN DRAIN PIPED
TO
EXTERIOR
WET PIPE ALARM
CHECK
VALVE
PROVIDE SLEEVE
THROUGH FLOOR
PROVIDE TIE RODS PER NFPA 24
PROVIDE THRUSTBLOCK PER
NFPA 24
8" UNDERGROUND FIRE
SUPPLY
1ST FL
0.0
2ND FL
9.8
BASEMENT FLOOR
-9.8
ROOF
29.5
3RD FLOOR
19.7
8" FIRE LEAD IN, SEE B1/CU102 FOR CONTINUATION.
FOR BACKFLOW PREVENTER DETAIL SEE A6/CU503.
FOR TEST HEADER AND FIRE DEPARTMENT
CONNECTION DETAIL SEE A1/CU508
6" FIRE SPRINKLER
RISER. RE: F9/FX502
FOR FITTING DETAILS
TO FIRE SPRINKLER
SYSTEM SERVING
BASEMENT
TO FIRE SPRINKLER SYSTEM
SERVING 1ST FLOOR, MIDDLE
WING, AND EAST WING
TO FIRE SPRINKLER SYSTEM
SERVING 2ND FLOOR
TO FIRE SPRINKLER SYSTEM
SERVING 3RD FLOOR
(MUST BE INSTALLED IN AN ACCESSIBLE LOCATION)
AUTOMATIC AIR VENT
Y-TYPE STRAINER
SPRINKLER PIPE
NOTE:
PROVIDED BY
CONTRACTOR
ISOLATION BALL VALVE
(NORMALLY OPEN)
1. CONNECTION TO SPRINKLER PIPING AND ALL
PIPING TO AUTOMATIC AIR VENT SHALL BE
LOCATED ABOVE SPRINKLER PIPING.
BRANCHLINE
1" DOWN TO SPRINKLER
BELOW OBSTRUCTION
OBSTRUCTION GREATER THAN 48"
WIDE OR WITHIN 18" OF SPRINKLER
OVERHEAD
1" PLUG
1" GLOBE VALVE
UPRIGHT SPRINKLER WITH
HEAD GUARD
STRUCTURE
SUPPORT BRACKET
LATERAL SWAY BRACE
LONGITUDINAL
SWAY BRACING
STAINLESS STEEL BRAIDED FITTING
DRAIN PLUG
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
B
IM
/U
S H
I_ D
U
S A
C E
M
D T
F
B u ild in g
/R
Y J B
L D
G D
M M
F .r v t
/1
/2
:2
:0
P
M
FX502
F
IR
E S
P R
IN
K
L E
R D
E T
A
IL
S
H E
L E
M A
N O
M
IL
IT
A
R Y
R E
S E
R V
A T
IO
N
O
A H
U H
I
H O
N O
L U
L U
D
IS
T R
IC
T
B L D
G
R
O O
M
F
O R
T S
H A
F T
E R
H
I -5
J A
C O
B S
-A H
L J
V B
IS
H
O P
S T
S U
IT
E
H
O N
O L U
L U
H
I
J C
A M
P B
E L L
D N
G U
Y E
N
S Y
I
S B
A C
H T
E L H
E
IM
E R
M A
R C
H
W A
F
W A
-1 -D
-0
R T
A S
U B
M
IT
T A
L
F Y
M
D T
F
B
U
IL
D
IN
G
R Y
J
NTSA1
WET-PIPE SYSTEM AUXILIARY
DRAIN/INSPECTOR'S TEST DETAIL
NTSA9
TYPICAL FLOOR CONTROL VALVE
NTSF9
WET PIPE RISER DETAIL
1/4" = 1'-0"F15
FIRE SPRINKLER RISER SECTION VIEW
NTSA15
AUTOMATIC AIR VENT INSTALLED AT HIGH
POINT OF EACH SYSTEM
0 2' 4' 8'12" = 1'-0"F1
SPRINKLERS BELOW OBSTRUCTIONS
NTSJ1
SEISMIC EXPANSION LOOP
APPLICABLE CODES AND
STANDARDS
• UFC 1-200-01 - DoD BUILDING CODE CHANGE 1, 1 OCTOBER 2020
• UFC 3-490-01 - ELEVATORS CHANGE 1, 18 JANUARY 2021
• UFC 3-520-01 - INTERIOR ELECTRICAL SYSTEMS CHANGE 2, 12 APRIL
• UFC 3-520-05 - STATIONARY AND MISSION BATTERIES CHANGE 2, 09
JANUARY 2020
• UFC 3-600-01 - FIRE PROTECTION ENGINEERING FOR FACILITIES
CHANGE 6, 6 MAY 2021
• UFC 4-010-01 - DoD MINIMUM ANTITERRORISM STANDARDS FOR
BUILDINGS CHANGE 1, 19 AUGUST 2020
• UFC 4-010-05 - SENSITIVE COMPARTMENTED INFORMATION
FACILITIES PLANNING, DESIGN, AND CONSTRUCTION CHANGE 1, 1
OCTOBER 2013
• UFC 4-010-06 - CYBERSECURITY OF FACILITY-RELATED CONTROL
SYSTEMS CHANGE 1, 18 JANUARY 2017
• UFC 4-021-01 - DESIGN AND O&M: MASS NOTIFICATION SYSTEMS
CHANGE 1, JANUARY 2010
• NFPA 1 - FIRE CODE 2021
• NFPA 10 - STANDARD FOR PORTABLE FIRE EXTINGUISHERS 2018
• NFPA 13 - STANDARD FOR THE INSTALLATION OF SPRINKLER
SYSTEMS 2019
• NFPA 24 - STANDARD FOR THE INSTALLATION OF PRIVATE FIRE
SERVICE MAINS AND THEIR APPURTENANCES 2019
• NFPA 70 - NATIONAL ELECTRICAL CODE 2020
• NFPA 72 - NATIONAL FIRE ALARM AND SIGNALING CODE 2019
• NFPA 80 - STANDARD FOR FIRE DOORS AND OTHER OPENING
PROTECTIVES 2019
• NFPA 90A - STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING
AND VENTILATING SYSTEMS 2021
• NFPA 101 - LIFE SAFETY CODE (LSC) 2021
• NFPA 110 - STANDARD FOR EMERGENCY AND STANDBY POWER
SYSTEMS 2019
• NFPA 220 - STANDARD ON TYPES OF BUILDING CONSTRUCTION 2021
• NFPA 291 - RECOMMENDED PRACTICE FOR FIRE FLOW TESTING AND
MARKING OF HYDRANTS 2019
• INTERNATIONAL BUILDING CODE (IBC) 2018
• ARCHITECTURAL BARRIERS ACT (ABA) STANDARDS
• UNIFIED FACILITIES GUIDE SPECIFICATIONS (UFGS)
• ASME 17.1 SAFETY CODE FOR ELEVATORS AND ESCALATORS 2019
MEANS OF EGRESS (LSC)
• EXIT ACCESS CORRIDOR FIRE RESISTANCE RATING: 0 HOUR
SEPARATION (38.3.6.1 (3))
• MINIMUM EXIT DOOR WIDTH: NOT LESS THAN 32 INCHES IN CLEAR
WIDTH (7.2.1.2.3.2)
• EGRESS WIDTH PER OCCUPANT: 0.2 INCHES / OCCUPANT FOR THE
OTHER ELEMENTS (TABLE 7.3.3.1)
• MINIMUM WIDTH OF EXIT ELEMENTS: NOT LESS THAN 36 INCHES
(7.3.4.1(2))
• MINIMUM WIDTH OF CORRIDORS: NOT LESS THAN 44 INCHES (38.2.3.2)
• STAIRWAY WIDTH PER OCCUPANT: 0.3 INCHES / OCCUPANT (TABLE
7.3.3.1)
OCCUPANCY GROUPS
MIXED USE, NON-SEPARATE OCCUPANCY IN ACCORDANCE WITH IBC
SECTION 508.3.
• ASSEMBLY, GROUP A-3*
• BUSINESS, GROUP B
• LOW-HAZARD, GROUP S-2
*SMALL ASSEMBLY SPACES WITH OCCUPANT LOADS OF LESS THAN 50
PERSONS OR LESS THAN 750 SF IN AREA ARE CLASSIFIED AS GROUP B
OCCUPANCIES IN ACCORDANCE WITH IBC SECTION 303.1.2.
TYPE OF CONSTRUCTION
• TYPE II-B NON-COMBUSTIBLE (IBC TABLE 602)
• FULLY SPRINKLERED
• SEISMIC CATEGORY D
FIRE RESISTIVE RATING
RATING REQUIREMENT FOR BUILDING ELEMENTS (IBC TABLE 601)
• PRIMARY STRUCTURAL FRAME: 0 HOUR
• BEARING WALLS:
EXTERIOR: 0 HOUR
INTERIOR: 0 HOUR
• NON-BEARING INTERIOR WALLS:
INTERIOR: 0 HOUR
• FLOOR CONSTRUCTION: 0 HOUR
• ROOF CONSTRUCTION: 0 HOUR
RATING REQUIREMENT FOR EXTERIOR WALLS BASED ON FIRE SEPARATION
DISTANCE (IBC TABLE 602)
• NON-BEARING WALLS:
MAIN BUILDING, NORTH, EAST AND WEST WALL:
10 FEET ≤ X EXTERIOR: 0 HOUR
SOUTH WEST WALL B303:
5 ≤ X ≤ 10 FEET EXTERIOR: 1 HOUR
BUILDING HEIGHT AND AREAS
ALLOWABLE HEIGHT AND BUILDING AREAS:
• NUMBER OF STORIES: 3 (A-3)
(IBC TABLE 504.4)
• BUILDING HEIGHT LIMITATION: 75 FEET (A-3)
(IBC TABLE 504.3)
• BUILDING AREA LIMITATION : 28,500 (A-3)
PER FLOOR (IBC TABLE 506.2)
ACTUAL HEIGHT AND BUILDING AREAS:
• NUMBER OF STORIES: 3
• ACTUAL BUILDING HEIGHT : 39 FEET
• ACTUAL AREA BASEMENT: 5,585 SF
• ACTUAL AREA 1ST FLOOR: 25,615 SF
• ACTUAL AREA 2ND FLOOR: 19,598 SF
• ACTUAL AREA 3RD FLOOR: 16,988 SF
OTHER FIRE RATING
ENCLOSED EXIT STAIRWELLS: 1 HOUR
(LSC SECTION 7.1.3.2.1)
EXTERIOR STAIRWELLS: 1 HOUR
(LSC SECTION 7.2.2.6.3
ELEVATOR SHAFT AND MACHINE ROOM: 1 HOUR
(LSC SECTION 8.6.5)
STORAGE ROOMS OVER 100 SF: 1 HOUR*
(LSC SECTION 38.3.2.1)
UPS ROOM: 1 HOUR
(NFPA 1 SECTION 52.2.3.3.3)
SERVER, MECHANICAL, AND ELECTRICAL ROOMS: SMOKE PARTITION*
*LSC SECTION 8.7.1.22 PERMITS SMOKE PARTITIONS IN LIEU OF FIRE-
RESISTIVE SEPARATION WHEN BUILDING IS PROTECTED BY AUTOMATIC
EXTINGUISHING SYSTEMS.
MEANS OF EGRESS
LSC SECTION 7.2.1.2.3.2 MINIMUM EXIT DOOR WIDTH (32 INCHES CLEAR)
LSC SECTION 40.2.4.1.1 MINIMUM NUMBER OF MEANS OF EGRESS 2
LSC TABLE A7.6 TRAVEL DISTANCE LIMIT
BUSINESS 300 FEET
ASSEMBLY 250 FEET
STORAGE 400 FEET
LSC TABLE A7.6 COMMON PATH OF TRAVEL LIMIT
BUSINESS 100 FEET
ASSEMBLY 20 FEET >50 PERSONS
75 FEET <50 PERSONS
STORAGE 100 FEET
LSC TABLE A7.6 DEAD-END CORRIDOR LIMIT
BUSINESS 50 FEET
ASSEMBLY 20 FEET
STORAGE 100 FEET
1. ENSURE THE CONTINUITY AND MAINTAIN THE PRIORITY OF RATED
ASSEMBLIES AND SMOKE ASSEMBLIES THAT ARE INDICATED.
2. PROVIDE CONTINUOUS SEALANT AT TOPS AND BOTTOMS OF SMOKE
PARTITIONS AND AT PENETRATIONS THROUGH SMOKE PARTITIONS
COMPATIBLE WITH THE PARTITION AND ALLOWING FOR STRUCTURAL
MOVEMENT.
3. REFER TO FIRE PROTECTION AND ELECTRICAL SHEETS FOR
LOCATION OF FIRE ALARM NOTIFICATION DEVICES, MANUAL FIRE
ALARM BOXES, PULL STATIONS AND EXIT SIGNAGE.
4. FOR EMERGENCY LIGHTING AND ILLUMINATED EXIT SIGNS
REFERENCE ELECTRICAL SHEETS.
5. PORTABLE FIRE EXTINGUISHERS MUST BE INSTALLED IN
ACCORDANCE WITH NFPA 10, UFC 3-600-01 AND UFC 4-010-05.
6. PROVIDE MARKINGS AND IDENTIFICATION OF ACCESSIBLE
CONCEALED FLOOR, FLOOR-CEILING SPACE, FIRE WALLS, FIRE
BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS, AND SMOKE
PARTITIONS OR ANY OTHER WALL REQUIRED TO HAVE PROTECTED
OPENINGS OR PENETRATIONS MUST BE EFFECTIVELY AND
PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING IN THE
CONCEALED SPACE. BE LOCATED WITHIN 15 FEET OF THE END OF
EACH WALL AND AT INTERVALS NOT EXCEEDING 30 FEET MEASURED
HORIZONTALLY ALONG WALL OR PARTITION. INCLUDE LETTERING
NOT LESS THAN 3 INCHES IN HEIGHT WITH A MINIMUM 3/8 INCH
STROKE IN A CONTRASTING COLOR INCORPORATING THE
SUGGESTED WORDING, "FIRE AND/OR SMOKE BARRIER - PROTECT
OPENINGS", OR OTHER WORDING.
LIFE SAFETY NOTES
LIFE SAFETY LEGEND
EXIT LOCATION (DOOR NUMBER)
INDICATES START OF CP & TD
INDICATES END OF CP
INDICATES POINT OF EXIT
CALCULATED ROOM OCCUPANCY LOAD
123B
160/160
146 TD 75 CP
1 HOUR FIRE RATED PARTITION
TOTAL REQUIRED EXIT CAPACITY OF OPENING IN
NUMBER OF OCCUPANTS
PATH OF EXIT TRAVEL WITH DISTANCES FROM SELECTED REMOTE
LOCATIONS TO NEAREST EXIT. INCLUDES; TOTAL TRAVEL DISTANCE (TD)
AND COMMON PATH OF TRAVEL(CP).
EXIT LIGHT FIXTURE, REFER TO ELECTRICAL
DRAWINGS
ROOM NUMBER117
S SMOKE PARTITION
TOTAL PROVIDED EXIT CAPACITY OF OPENING IN
NUMBER OF OCCUPANTS
OCCUPANT LOAD (LSC)
OCCUPANT USE OCCUPANT LOAD
FACTOR
BUSINESS
ASSEMBLY*
STORAGE
MECH/ELEC EQUIPMENT*
CONCENTRATED BUSINESS USE
COLLABORATION**
IT EQUIPMENT ROOMS
150 GROSS
15 NET
500 GROSS
500 GROSS
50 GROSS
30 GROSS
300 GROSS
*OCCUPANT LOAD FACTOR BASED ON UFC 3-600-01 TABLE 10-1
**COLLABORATION ROOMS/SPACES < 450 SF IN AREA
MEANS OF EGRESS CAPACITY (LSC)
STAIRWAYS OCCUPANT LOAD CAPACITY FACTOR WIDTH REQUIRED WIDTH PROVIDED LOAD CAPACITY
EAST WING 2ND 43 0.3 13 IN (2)36=72 IN 240 PERSONS
LEVEL 1 38 0.3 11 IN 36 IN 120 PERSONS
LEVEL 2 336 0.3 101 IN (2)36+(2)41=154 513 PERSONS
LEVEL 3 224 0.3 67 IN (2)36+(2)41=154 513 PERSONS
LEVEL COMPONENT FLOOR OCCUPANT LOAD CAPACITY FACTOR WIDTH REQUIRED WIDTH PROVIDED LOAD CAPACITY
BASEMENT 136 0.2 27 IN (4)35=140 IN 700 PERSONS
MIDDLE WING 143 0.2 29 IN (2)35=70 IN 350 PERSONS
EAST WING 1ST 33 0.2 7 IN (2)35=70 IN 350 PERSONS
EAST WING 2ND 43 0.2 9 IN 35+31=66 IN 330 PERSONS
LEVEL 1 226 0.2 45 IN (2)35+(2)59+(2)71=330 IN 1650 PERSONS
LEVEL 2 336 0.2 67 IN (4)35=140 IN 700 PERSONS
LEVEL 3 224 0.2 45 IN (4)35=140 IN 700 PERSONS
INTERIOR FINISH RATING
NEW BUSINESS
MAXIMUM FLAME SPREAD
EXIT: A OR B (0 - 75)
I OR II
EXIT ACCESS CORRIDORS: A OR B (0 - 75)
OTHER SPACES: A, B, OR C (0 - 200)
MAXIMUM SMOKE DEVELOPED
ALL AREAS: 0 - 450
ASSEMBLY > 300
MAXIMUM FLAME SPREAD
EXIT: A (0 - 25)
I OR II
EXIT ACCESS CORRIDORS: A OR B (0 - 75)
I OR II
OTHER SPACES: A OR B (0 - 75)
MAXIMUM SMOKE DEVELOPED
ALL AREAS: 0 - 450
STORAGE
MAXIMUM FLAME SPREAD
EXIT: A OR B (0 - 75)
I OR II
EXIT ACCESS CORRIDORS: A, B OR C (0 - 200)
OTHER SPACES: A, B, OR C (0 - 200)
MAXIMUM SMOKE DEVELOPED
ALL AREAS: 0 - 450
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
B
IM
/U
S H
I_ D
U
S A
C E
M
D T
F
B u ild in g
/R
Y J B
L D
G D
M M
F .r v t
/1
/2
:2
:0
P
M
G-005
C O
D E
A N
A L Y
S
IS
H E
L E
M A
N O
M
IL
IT
A
R Y
R E
S E
R V
A T
IO
N
O
A H
U H
I
H O
N O
L U
L U
D
IS
T R
IC
T
B L D
G
R
O O
M
F
O R
T S
H A
F T
E R
H
I -5
J A
C O
B S
-A H
L J
V B
IS
H
O P
S T
S U
IT
E
H
O N
O L U
L U
H
I
J C
A M
P B
E L L
D N
G U
Y E
N
S Y
I
S B
A C
H T
E L H
E
IM
E R
M A
R C
H
W A
F
W A
-1 -D
-0
R T
A S
U B
M
IT
T A
L
F Y
M
D T
F
B
U
IL
D
IN
G
R Y
J
TOTAL 136
ROOM
NUMBER ROOM NAME
IBC
OCCUPANCY
LSC
OCCUPANCY USE
ROOM AREA
(SF)
LOAD FACTOR
(SF/PERSON)
CALCULATED
OCCUPANT LOAD
B101 LARGE CONFERENCE A-3 ASSEMBLY ASSEMBLY USE 1539 15 105
B102 CHAPLAIN B BUSINESS CONCENTRATED USE 463 50 9
B103 ASSIST. CHAPLAIN B BUSINESS BUSINESS USE 171 150 1
B108 JAN B BUSINESS BUSINESS USE 29 150 1
B109 WATER HEATER S-2 STORAGE MECH/ELEC USE 231 500 1
B110 STORAGE S-2 STORAGE STORAGE USE 33 500 1
B111 ELEC CLOSET S-2 STORAGE MECH/ELEC USE 32 500 1
B104 STORAGE 4 S-2 STORAGE STORAGE USE 162 500 1
B105 FP S-2 STORAGE MECH/ELEC USE 117 500 1
B106 MEN B BUSINESS BUSINESS USE 175 150 1
B107 WOMEN B BUSINESS BUSINESS USE 218 150 1
B113 STORAGE 1 S-2 STORAGE STORAGE USE 156 500 1
B114 TR-0 S-2 STORAGE MECH/ELEC USE 140 500 1
B115 ARMS RM S-2 STORAGE STORAGE USE 269 500 1
CORRIDOR 357 150 3B117A
CORRIDOR
B BUSINESS BUSINESS USE
245 150 2
B118
ARMS RM
S-2 STORAGE STORAGE USE
234 500 1B119
ARMS RM
S-2 STORAGE STORAGE USE
265 500 1B120
STORAGE 5
S-2 STORAGE STORAGE USE
111 500 1B121 S-2 STORAGE STORAGE USE
99 500 1B122 MECH S-2 STORAGE STORAGE USE
TOTAL
ROOM
NUMBER ROOM NAME
IBC
OCCUPANCY
LSC
OCCUPANCY USE
ROOM AREA
(SF)
LOAD FACTOR
(SF/PERSON)
CALCULATED
OCCUPANT LOAD
E100 CORRIDOR 1 B BUSINESS BUSINESS USE 327 150 2
E101 SECURED VEST (W/ SSO) B BUSINESS BUSINESS USE 121 150 1
E102 WELLNESS B BUSINESS BUSINESS USE 92 150 1
E111 ELEC S-2 STORAGE MECH/ELEC USE 149 500 1
E112 MECH S-2 STORAGE MECH/ELEC USE 157 500 1
E113 UPS S-2 STORAGE MECH/ELEC USE 147 500 1
E114 TR S-2 STORAGE MECH/ELEC USE 157 500 1
E107 HHD OFFICE B BUSINESS BUSINESS USE 140 150 1
E108 HHD TEAM B BUSINESS BUSINESS USE 169 150 2
E109 SPACE TEAM B BUSINESS BUSINESS USE 143 150 1
E110 SPACE OFFICE B BUSINESS BUSINESS USE 144 150 1
E206 MI OFFICE B BUSINESS BUSINESS USE 135 150 1
E207 CEMA OFFICE B BUSINESS BUSINESS USE 137 150 1
E208 SHARED CONF A-3 ASSEMBLY BUSINESS USE 174 15 12
2G STAIR B BUSINESS BUSINESS USE 113 150 1
E103 RESTROOM 1-A B BUSINESS BUSINESS USE 84 150 1
E104 JAN S-2 STORAGE STORAGE USE 28 500 1
E105 RESTROOM 1-B B BUSINESS BUSINESS USE 97 150 1
E106 SHARED CONF B BUSINESS BUSINESS USE 187 15 16
E202 RESTROOM 2-A B BUSINESS BUSINESS USE 81 150 1
E203 RESTROOM 2-B B BUSINESS BUSINESS USE 98 150 1
E204 CEMA TEAM B BUSINESS CONCENTRATED USE 713 50 14
E205A MI TEAM B BUSINESS CONCENTRATED USE 327 50 6
1G STAIR B BUSINESS BUSINESS USE 112 150 1
TOTAL
E200 CORRIDOR 2 B BUSINESS BUSINESS USE 333 150 2
E201 SECURED VEST (W/ SSO) B BUSINESS BUSINESS USE 184 150 1
TGT DEV ELEMENT B BUSINESS CONCENTRATED USE 521 50 10
S6 OFFICE B BUSINESS BUSINESS USE 158 150 1
S6 B BUSINESS BUSINESS USE 125 150 1
EL-1
S6 IT/NTWRK STORAGE S-2 STORAGE STORAGE USE 223 500 1
ELEV B BUSINESS BUSINESS USE 83 150 1
TOTAL 226
ROOM
NUMBER ROOM NAME
IBC
OCCUPANCY
LSC
OCCUPANCY USE
ROOM AREA
(SF)
LOAD FACTOR
(SF/PERSON)
CALCULATED
OCCUPANT LOAD
100A CORRIDOR B BUSINESS BUSINESS USE 939 150 6
100B CORRIDOR B BUSINESS BUSINESS USE 483 150 4
100C CORRIDOR B BUSINESS BUSINESS USE 835 150 6
101 COMM STOR S-2 STORAGE STORAGE USE 179 500 1
102 NBC STOR S-2 STORAGE STORAGE USE 172 500 1
103 UNIT STORAGE S-2 STORAGE STORAGE USE 351 500 1
104 SECURE STORAGE S-2 STORAGE STORAGE USE 351 500 1
105 CONFERENCE ROOM A-3 ASSEMBLY BUSINESS USE 333 15 23
106 CO B BUSINESS BUSINESS USE 159 150 1
107 XO B BUSINESS BUSINESS USE 163 150 1
108 1ST SGT B BUSINESS BUSINESS USE 163 150 1
109 TRAINING B BUSINESS BUSINESS USE 159 150 1
110 PLATOON B BUSINESS BUSINESS USE 156 150 1
111 CMD STOR S-2 STORAGE STORAGE USE 88 150 1
112 BDE S1 B BUSINESS CONCENTRATED USE 258 50 2
113 BDE S1 OFFICE B BUSINESS BUSINESS USE 163 150 1
1C STAIR B BUSINESS BUSINESS USE 163 150 1
115 EXIT LOBBY B BUSINESS BUSINESS USE 133 150 1
116 WELLNESS B BUSINESS BUSINESS USE 126 150 1
117 BREAKROOM B BUSINESS CONCENTRATED USE 408 50 8
118 SHARED CONF A-3 ASSEMBLY BUSINESS USE 487 15 33
ELEC S-2 STORAGE MECH/ELEC USE 242 500 1
1D
LOBBY B BUSINESS BUSINESS USE 600 150 4
STAIR B BUSINESS BUSINESS USE 121 150 1
1ST SGT B BUSINESS BUSINESS USE 162 150 1
ORDERLY B BUSINESS BUSINESS USE 253 150 2
TOILET B BUSINESS BUSINESS USE 27 150 1
CO B BUSINESS BUSINESS USE 215 150 1
XO B BUSINESS BUSINESS USE 161 150 1
XO B BUSINESS BUSINESS USE 161 150 1
RETENTION B BUSINESS BUSINESS USE 158 150 1
CBRN B BUSINESS BUSINESS USE 159 150 1
SUPPLY B BUSINESS BUSINESS USE 163 150 1
ELEC S-2 STORAGE MECH/ELEC USE 9 500 1
MEETING ROOM 1 A-3 ASSEMBLY BUSINESS USE 315 15 22
COMP LAB B BUSINESS CONCENTRATED USE 331 50 7
CBRN 1 B BUSINESS BUSINESS USE 166 150 1
CBRN 2 B BUSINESS BUSINESS USE 166 150 1
MEETING ROOM 2 A-3 ASSEMBLY BUSINESS USE 331 15 22
TRAINING B BUSINESS BUSINESS USE 158 150 1
TRAINING B BUSINESS BUSINESS USE 158 150 1
SUPPLY B BUSINESS BUSINESS USE 162 150 1
FP S-2 STORAGE MECH/ELEC USE 80 500 1
MECH-1A S-2 STORAGE MECH/ELEC USE 165 500 1
JAN S-2 STORAGE STORAGE USE 20 500 1
WOMEN B BUSINESS BUSINESS USE 162 150 1
MEN B BUSINESS BUSINESS USE 159 150 1
TOILET B BUSINESS BUSINESS USE 46 150 1
CO STOR S-2 STORAGE STORAGE USE 54 500 1
CO B BUSINESS BUSINESS USE 208 150 1
ORDERLY B BUSINESS BUSINESS USE 202 150 1
1ST SGT B BUSINESS BUSINESS USE 162 150 1
TR-1A S-2 STORAGE MECH/ELEC USE 153 500 1
SJA OFFICE B BUSINESS BUSINESS USE 124 150 1
S4 OFFICE B BUSINESS BUSINESS USE 152 150 1
S4 B BUSINESS CONCENTRATED USE 190 50 4
CYBERSEC B BUSINESS CONCENTRATED USE 320 50 6
ELEC S-2 STORAGE MECH/ELEC USE 17 500 1
TR-1B S-2 STORAGE MECH/ELEC USE 138 500 1
MECH 1-B S-2 STORAGE MECH/ELEC USE 174 500 1
WOMEN B BUSINESS BUSINESS USE 219 150 2
MEN B BUSINESS BUSINESS USE 216 150 1
JAN S-2 STORAGE STORAGE USE 32 500 1
STORAGE S-2 STORAGE STORAGE USE 84 500 1
1F
307 ESB SECURITY B BUSINESS BUSINESS USE 60 150 1
STAIR B BUSINESS BUSINESS USE 91 150 1
MDTF SECURITY B BUSINESS BUSINESS USE 58 150 1
ARMS RM S-2 STORAGE STORAGE USE 255 500 1
ARMS RM S-2 STORAGE STORAGE USE 330 500 1
ARMS RM S-2 STORAGE STORAGE USE 331 500 1
1E
STAFF SECT STORAGE S-2 STORAGE STORAGE USE 342 500 1
STAIR B BUSINESS BUSINESS USE 91 150 1
SJA B BUSINESS BUSINESS USE 87 150 1
ROOM
NUMBER ROOM NAME
IBC
OCCUPANCY
LSC
OCCUPANCY USE
ROOM AREA
(SF)
LOAD FACTOR
(SF/PERSON)
CALCULATED
OCCUPANT LOAD
M100 CORRIDOR B BUSINESS BUSINESS USE 682 150 5
M101 SECURED VEST B BUSINESS BUSINESS USE 140 150 1
M102 SSO B BUSINESS BUSINESS USE 108 150 1
M103 ADOC B BUSINESS CONCENTRATED USE 2051 50 41
M104 DCO LAB B BUSINESS CONCENTRATED USE 318 50 6
M108 MEN B BUSINESS BUSINESS USE 131 150 1
M109 WOMEN B BUSINESS BUSINESS USE 48 150 1
M110 WELLNESS B BUSINESS BUSINESS USE 55 150 1
M105 RF LAB B BUSINESS CONCENTRATED USE 318 50 6
M106 BDE HQ (CDR) B BUSINESS BUSINESS USE 167 150 1
M107 BDE HQ DEPUTY B BUSINESS BUSINESS USE 111 150 1
M114 ADOC COM A-3 ASSEMBLY BUSINESS USE 193 15 13
M115 CMD VTC CONF A-3 ASSEMBLY BUSINESS USE 555 15 37
M116 ELECTRICAL S-2 STORAGE MECH/ELEC USE 120 500 1
M111 JAN S-2 STORAGE STORAGE USE 27 500 1
M112 BREAK RM B BUSINESS BUSINESS USE 111 150 1
M113 SEC COM A-3 ASSEMBLY BUSINESS USE 457 15 31
M117 MECHANICAL S-2 STORAGE MECH/ELEC USE 226 500 1
M118 UPS S-2 STORAGE MECH/ELEC USE 184 500 1
E201A JAN S-2 STORAGE STORAGE USE 22 500 1
M119 EMERGENCY POWER ROOM S-2 STORAGE MECH/ELEC USE 89 1
TOTAL 151
B117B
ARMS RM
B BUSINESS BUSINESS USE
285 500 1
E205B MI TEAM OPEN OFFICE B BUSINESS BUSINESS USE 166 150 2
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
B
IM
/U
S H
I_ D
U
S A
C E
M
D T
F
B u ild in g
/R
Y J B
L D
G D
M M
F .r v t
/1
/2
:2
:0
P
M
G-006
R O
O M
O C
C U
P A
N T
L O
A D
S C
H E
D U
L E
H E
L E
M A
N O
M
IL
IT
A
R Y
R E
S E
R V
A T
IO
N
O
A H
U H
I
H O
N O
L U
L U
D
IS
T R
IC
T
B L D
G
R
O O
M
F
O R
T S
H A
F T
E R
H
I -5
J A
C O
B S
-A H
L J
V B
IS
H
O P
S T
S U
IT
E
H
O N
O L U
L U
H
I
J C
A M
P B
E L L
D N
G U
Y E
N
S Y
I
S B
A C
H T
E L H
E
IM
E R
M A
R C
H
W A
F
W A
-1 -D
-0
R T
A S
U B
M
IT
T A
L
F Y
M
D T
F
B
U
IL
D
IN
G
R Y
ROOM
NUMBER ROOM NAME
IBC
OCCUPANCY
LSC
OCCUPANCY USE
ROOM AREA
(SF)
LOAD FACTOR
(SF/PERSON)
CALCULATED
OCCUPANT LOAD
200A CORRIDOR B BUSINESS BUSINESS USE 1009 150 7
200B CORRIDOR B BUSINESS BUSINESS USE 514 150 3
200C CORRIDOR B BUSINESS BUSINESS USE 789 150 5
200D BRIDGE CORRIDOR B BUSINESS BUSINESS USE 85 150 1
201 BDE CMD OFFICE B BUSINESS BUSINESS USE 169 150 1
202 BDE CMD OFFICE B BUSINESS BUSINESS USE 175 150 1
203 BDE CMD OFFICE B BUSINESS BUSINESS USE 210 150 1
204 BDE CMD GROUP B BUSINESS CONCENTRATED USE 239 50 5
205 SIPR CAFE B BUSINESS CONCENTRATED USE 556 50 11
206 TRAINING B BUSINESS CLASSROOM USE 1333 20 67
2C STAIR B BUSINESS BUSINESS USE 130 150 1
208 NBC STOR S-2 STORAGE STORAGE USE 130 500 1
209 COMM STOR S-2 STORAGE STORAGE USE 111 500 1
210 UNIT STORAGE S-2 STORAGE STORAGE USE 225 500 1
211 SHARED CONF (S2) A-3 ASSEMBLY BUSINESS USE 709 15 48
212 ELEC S-2 STORAGE MECH/ELEC USE 247 500 1
213 LOBBY B BUSINESS BUSINESS USE 621 150 4
2D STAIR B BUSINESS BUSINESS USE 121 150 1
215 HHC STOR S-2 STORAGE STORAGE USE 173 500 1
216 HHC STOR S-2 STORAGE STORAGE USE 173 500 1
217 S4 SHOP B BUSINESS CONCENTRATED USE 286 50 6
218 RESTROOM 33 1
219 NCOIC B BUSINESS BUSINESS USE 159 150 1
220 S4 OIC B BUSINESS BUSINESS USE 158 150 1
221 OIC B BUSINESS BUSINESS USE 158 150 1
222 NCOIC B BUSINESS BUSINESS USE 158 150 1
223 S1 SHOP B BUSINESS CONCENTRATED USE 317 50 6
224 ELEC S-2 STORAGE MECH/ELEC USE 9 500 1
225 STORAGE S-2 STORAGE STORAGE USE 173 500 1
226 STORAGE S-2 STORAGE STORAGE USE 172 500 1
227 STORAGE S-2 STORAGE STORAGE USE 172 500 1
228 STORAGE S-2 STORAGE STORAGE USE 180 500 1
229 HHC CONF A-3 ASSEMBLY BUSINESS USE 340 15 23
230 HHC CO B BUSINESS BUSINESS USE 160 150 1
231 ORDERLY B BUSINESS BUSINESS USE 160 150 1
232 ORDERLY B BUSINESS BUSINESS USE 160 150 1
233 1SG B BUSINESS BUSINESS USE 163 150 1
234 FP S-2 STORAGE MECH/ELEC USE 80 500 1
235 MECH-2A S-2 STORAGE MECH/ELEC USE 175 500 1
236 JAN S-2 STORAGE STORAGE USE 20 500 1
237 WOMEN B BUSINESS BUSINESS USE 243 150 1
238 MEN B BUSINESS BUSINESS USE 255 150 1
239 PBO B BUSINESS BUSINESS USE 158 150 1
240 HHC SUPPLY B BUSINESS BUSINESS USE 159 150 1
241 HHC XO B BUSINESS BUSINESS USE 159 150 1
242 TR-2A S-2 STORAGE MECH/ELEC USE 149 500 1
243 WELLNESS B BUSINESS BUSINESS USE 159 150 1
244 EXP/VISIT SPACE B BUSINESS BUSINESS USE 158 150 1
245 PLATOON B BUSINESS BUSINESS USE 158 150 1
246 TRAINING A-3 ASSEMBLY BUSINESS USE 158 20 8
247 1ST SGT B BUSINESS BUSINESS USE 158 150 1
248 XO B BUSINESS BUSINESS USE 159 150 1
249 CO B BUSINESS BUSINESS USE 157 150 1
250 CONFERENCE A-3 ASSEMBLY BUSINESS USE 336 15 22
251 CMD STOR S-2 STORAGE STORAGE USE 135 500 1
252 SECURE STOR S-2 STORAGE STORAGE USE 198 500 1
253 SHARED CONF (S2) A-3 ASSEMBLY BUSINESS USE 283 15 19
254 S2 CUOPS (INTEL OPS) B BUSINESS CONCENTRATED USE 187 50 4
255 INTEL FUOPS B BUSINESS CONCENTRATED USE 196 50 4
256 ELEC S-2 STORAGE MECH/ELEC USE 16 500 1
257 TR-2B S-2 STORAGE MECH/ELEC USE 136 500 1
258 MECH-2B S-2 STORAGE MECH/ELEC USE 180 500 1
259 WOMEN B BUSINESS BUSINESS USE 218 150 2
260 MEN B BUSINESS BUSINESS USE 215 150 1
261 JAN S-2 STORAGE STORAGE USE 32 500 1
262 STORAGE S-2 STORAGE STORAGE USE 74 500 1
263 BDE S2 (INTEL HQ) B BUSINESS BUSINESS USE 166 150 1
264 BDE CDR CONF RM A-3 ASSEMBLY BUSINESS USE 552 15 37
265 INTEL GEOINT B BUSINESS CONCENTRATED USE 211 50 4
EL-2 ELEV B BUSINESS BUSINESS USE 77 150 1
TOTAL 336
ROOM
NUMBER ROOM NAME
IBC
OCCUPANCY
LSC
OCCUPANCY USE
ROOM AREA
(SF)
LOAD FACTOR
(SF/PERSON)
CALCULATED
OCCUPANT LOAD
300A CORRIDOR B BUSINESS BUSINESS USE 959 150 6
300B CORRIDOR B BUSINESS BUSINESS USE 514 150…