M-600_AMDT 0002.pdf

PDF 136 KB Posted

Attached to
Dexter Adult Fish Facility Upgrades
Solicitation number
W9127N23R0005
Issued by

About this file

This valve and actuator schedule and related federal contract opportunity document outline requirements for upgrades to the Dexter Adult Fish Facility. The solicitation seeks construction services to improve, replace, and add features to the fish facility per requirements of the National Marine Fisheries Service 2008 biological opinion. Work is anticipated from March 2023 to November 2026 with an estimated value between $25-100 million. The unrestricted, full and open competition uses NAICS code 237990 and has a small business size standard of $39.5 million. The solicitation will apply the HUBZone 10% price preference and is issued by the Department of the Army Corps of Engineers Portland District for the Dexter Fish Facility Upgrades project. The valve and actuator schedule provides specifications for over 60 valves and actuators across the facility including size, type, voltage, location and identifies tags.

View the file

Other files

File Type Posted
Dexter Fish Facility W9127N23R0005 Amend 0005.pdf PDF
Dexter_Pre-Bid and Follow On Site Visit_Attendance List.pdf PDF
ProjectNet Inquiries and Responses - Dexter Fish Facilities.pdf PDF
Section 00 10 00 CLINS Structure AMDT 0004.pdf PDF
Drawings SR701_SR101_AMDT 0004.pdf PDF
Drawings MK502_M-600_M-002_MQ501_AMDT 0004.pdf PDF
DB Wage Rate OR20230057 01.06.2023_AMDT 0004.pdf PDF
Dexter Fish Facility W9127N23R0005 Amend 0004.pdf PDF
Spec 26 42 13.00 25_AMDT 0004.pdf PDF
Specs Attachment 1 - Submittal Register_AMDT 0004.pdf PDF
Drawings SK523_SK516-2_SK516_SK516-1_SK516-3_AMDT 0004.pdf PDF
Spec 33 61 13.19 25_AMDT 0004.pdf PDF
Spec 01 22 00.00 25_AMDT 0004.pdf PDF
Drawings CS103_CU105_CU201_CU102_CU103_AMDT 0004.pdf PDF
Clean Sol Package Drawings ELECTRICAL_AMDT 0003 Part4.pdf PDF
Clean Sol Package Drawings MECHANICAL_AMDT 0003.pdf PDF
Dexter W9127N23R0005 Clean Solicitation Package.pdf PDF
Clean Sol Package Drawings ELECTRICAL_AMDT 0003 Part1.pdf PDF
Clean Sol Package Drawings STRUCTURAL_AMDT 0003 Set 5 (SP).pdf PDF
Clean Sol Package Drawings ELECTRICAL_AMDT 0003 Part2.pdf PDF
Clean Sol Package Drawings GENERAL_AMDT 0003.pdf PDF
Clean Sol Package Drawings STRUCTURAL_AMDT 0003 Set 3 (SL-SN).pdf PDF
Clean Sol Package Drawings ELECTRICAL_AMDT 0003 Part3.pdf PDF
Clean Sol Package Drawings LANDSCAPE_AMDT 0003.pdf PDF
Clean Sol Package Drawings STRUCTURAL_AMDT 0003 Set 4 (SO-ST).pdf PDF
Clean Sol Package Drawings STRUCTURAL_AMDT 0003 Set 1 (S-SJ) - Part2.pdf PDF
Clean Sol Package Drawings STRUCTURAL_AMDT 0003 Set 2 (SK).pdf PDF
Clean Sol Package Drawings STRUCTURAL_AMDT 0003 Set 1 (S-SJ) - Part1.pdf PDF
Dexter Fish Facility W9127N23R0005 Amend 0003.pdf PDF
Clean Sol Package Drawings CIVIL_AMDT 0003.pdf PDF
STRUCTURES_AMDT 0002.pdf PDF
CU502_19DEC22_AMDT 0002.pdf PDF
MK502_AMDT 0002.pdf PDF
E-603_EL602_EN602_M-601_ML524_AMDT 0002.pdf PDF
MZ101_23DEC22_AMDT 0002.pdf PDF
MW101-MW501-MW502_AMDT 0002.pdf PDF
MY103_AMDT0002.pdf PDF
STRUCTURES_AMDT 0002.pdf PDF
CD501_19DEC22_AMDT 0002.pdf PDF
Dexter Amendment 0002 Spec Changes Package.pdf PDF
W9127N23R0005 Amendment 0002 12.29.22.pdf PDF
Dexter Road Photo Tour.pdf PDF
Dexter Fish Facility Photo Tour.pdf PDF
DXF1.101_ES101-A2 (Electrical_Update_Amend0002).pdf PDF
Attach 8 - Dexter GBR Update Amend0002.pdf PDF
DXF1.101_DEXTER FF UPGRADE_STRUCTURAL UPDATE AMEND 0002.pdf PDF
Attachment 10 - DSL Removal Fill Permit.pdf PDF
W9127N23R0005-Amendment 0001 12.5.2022.pdf PDF
Specs 01 22 00.00 25 M&P Amend 0001.pdf PDF
Site Visit Attendance Sheet - Dexter.pdf PDF
Show 40 more

Latest 50 of 71 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MARK SHEET DESCRIPTION LOCATION SIZE ACTUATOR SERVICE ACTUATOR VOLTAGE SCADA HP

DXF‐FWS‐EDC01 TBD SLIDE GATE ENTRANCE AREA, TAILRACE DISCHARGE 72" ELECTRIC MODULATING VAM‐EM1 480VAC YES 5 DXF‐FWS‐ADC01 MK503 BALL VALVE ENTRANCE AREA, VAULT 2 48" ELECTRIC MODULATING VAM‐EM2 480VAC YES 1 DXF‐FWS‐ADC02 MK503 BALL VALVE ENTRANCE AREA, VAULT 2 48" ELECTRIC MODULATING VAM‐EM3 480VAC YES 1 DXF‐FWS‐AWS01A MK503 SLIDE GATE ENTRANCE AREA, DIFFUSER CHAMBER 1 48" ELECTRIC OPEN/CLOSE VAM‐EM4 480VAC YES 1.5 DXF‐FWS‐AWS01B MK503 SLIDE GATE ENTRANCE AREA, DIFFUSER CHAMBER 1 48" ELECTRIC OPEN/CLOSE VAM‐EM5 480VAC YES 1.5 DXF‐FWS‐AWS02 MK503 SLIDE GATE ENTRANCE AREA, DIFFUSER CHAMBER 2 36" ELECTRIC OPEN/CLOSE VAM‐EM6 480VAC YES 0.33 DXF‐FWS‐AWS03 MK503 SLIDE GATE ENTRANCE AREA, DIFFUSER CHAMBER 3 36" ELECTRIC OPEN/CLOSE VAM‐EM7 480VAC YES 0.33 DXF‐FWS‐AWS04 MK503 SLIDE GATE ENTRANCE AREA, DIFFUSER CHAMBER 4 36" ELECTRIC OPEN/CLOSE VAM‐EM8 480VAC YES 0.33 DXF‐FWS‐AWS05 MK503 SLIDE GATE ENTRANCE AREA, DIFFUSER CHAMBER 5 36" ELECTRIC OPEN/CLOSE VAM‐EM9 480VAC YES 0.33 DXF‐FWS‐AWS06 MK503 SLIDE GATE ENTRANCE AREA, DIFFUSER CHAMBER 6 36" ELECTRIC OPEN/CLOSE VAM‐EM10 480VAC YES 0.33 DXF‐FWS‐APH01 MP501 GATE ASPHALT POND HEADER VAULT 3 12" ELECTRIC OPEN/CLOSE VAM‐EM11 480VAC YES 0.33

DXF‐FWS‐APD02 MP501 GATE ASPHALT POND DIFFUSER, MANHOLE 12" MANUAL OPEN/CLOSE

DXF‐FWS‐PSS01 MP503 BUTTERFLY PRESORT AREA, VAULT 4 30" ELECTRIC MODULATING VAM‐EM12 480VAC YES 1 DXF‐FWS‐PSS02 MP503 BUTTERFLY PRESORT AREA, VAULT 5 30" ELECTRIC MODULATING VAM‐EM13 480VAC YES 1 DXF‐FWS‐PRE01 MP504 BUTTERFLY PRESORT AREA, PLATFORM, EXPOSED, FLUME SUPPLY 6" ELECTRIC MODULATING VAM‐EM14 480VAC PSCC 0.75 DXF‐FWS‐PRE02 MP504 BUTTERFLY PRESORT AREA, OBSERV. PLATFORM, IN LINE EXPOSED, FALSE WEIR SUPPLY 10" ELECTRIC OPEN/CLOSE VAM‐EM15 480VAC PSCC 0.75 DXF‐FWS‐PRE03 MP504 BUTTERFLY PRESORT AREA, OBSERV. PLATFORM, FALSE WEIR DRAIN 6" MANUAL OPEN/CLOSE DXF‐FWS‐PRE04 MP503 BALL VALVE PRESORT AREA, VAULT 5, BRAIL PIT DRAIN 2.5" MANUAL OPEN/CLOSE DXF‐FWS‐UWI02 MP503 GATE EXISTING LADDER AREA‐ SURFACE SUPPORTED , VAULT 7 30" ELECTRIC OPEN/CLOSE VAM‐EM16 480VAC YES 1 DXF‐FWS‐UWD01 MP503 BALL VALVE EXISTING LADDER AREA, SURFACE SUPPORTED, VAULT 7 12" ELECTRIC MODULATING VAM‐EM17 480VAC YES 0.33 DXF‐FWS‐UWD02 MP503 BALL VALVE EXISTING LADDER AREA, SURFACE SUPPORTED, VAULT 7 24" ELECTRIC MODULATING VAM‐EM18 480VAC YES 0.33 DXF‐FWS‐PSP01 MP507 BUTTERFLY EXISTING LADDER AREA, VAULT X, OPERATOR STAND 18" MANUAL OPEN/CLOSE DXF‐FWS‐PST01 MP507 BUTTERFLY EXISTING LADDER AREA, VAULT 9, REMOVABLE TEE HANDLE 6" MANUAL OPEN/CLOSE DXF‐FWS‐PST02 MP507 BUTTERFLY EXISTING LADDER AREA, VAULT 9, REMOVABLE TEE HANDLE 6" MANUAL OPEN/CLOSE DXF‐FWS‐PST03 MP507 BUTTERFLY EXISTING LADDER AREA, VAULT 9, REMOVABLE TEE HANDLE 6" MANUAL OPEN/CLOSE DXF‐FWS‐PST04 MP507 BUTTERFLY EXISTING LADDER AREA, VAULT 9, REMOVABLE TEE HANDLE 6" MANUAL OPEN/CLOSE DXF‐FWS‐PST05 MP507 BUTTERFLY EXISTING LADDER AREA, VAULT 9, REMOVABLE TEE HANDLE 6" MANUAL OPEN/CLOSE DXF‐FWS‐PST06 MP507 BUTTERFLY EXISTING LADDER AREA, VAULT 9, REMOVABLE TEE HANDLE 6" MANUAL OPEN/CLOSE DXF‐FWS‐PST07 MP507 BUTTERFLY EXISTING LADDER AREA, VAULT 9, REMOVABLE TEE HANDLE 6" MANUAL OPEN/CLOSE DXF‐FWS‐PST08 MP507 BUTTERFLY EXISTING LADDER AREA, VAULT 9, REMOVABLE TEE HANDLE 6" MANUAL OPEN/CLOSE DXF‐FWS‐PST09 MP507 BUTTERFLY EXISTING LADDER AREA, VAULT 9, REMOVABLE TEE HANDLE 6" MANUAL OPEN/CLOSE DXF‐FWS‐PST10 MP507 BUTTERFLY EXISTING LADDER AREA, VAULT 9, REMOVABLE TEE HANDLE 6" MANUAL OPEN/CLOSE

DXF‐FWS‐STI01 MP510 BUTTERFLY SWITCHGATE AREA, VAULT 10 18" MANUAL OPEN/CLOSE

DXF‐FWS‐STS01 MP510 BUTTERFLY SWITCHGATE AREA, VAULT 10 16" MANUAL OPEN/CLOSE

DXF‐FWS‐SGI01 MP510 BUTTERFLY SWITCHGATE AREA, VAULT 10 18" MANUAL OPEN/CLOSE

DXF‐FWS‐PSF01 MP510 BUTTERFLY SWITCHGATE AREA, IN LINE WITH EXPOSED SUPPLY PIPE 6" ELECTRIC OPEN/CLOSE VAM‐EM19 480VAC CONSOLE 0.75 DXF‐FWS‐PSF02 MP510 BUTTERFLY SWITCHGATE AREA, IN LINE WITH EXPOSED SUPPLY PIPE 6" ELECTRIC OPEN/CLOSE VAM‐EM20 480VAC CONSOLE 0.75 DXF‐FWS‐PSF03 MP510 BUTTERFLY SWITCHGATE AREA, IN LINE WITH EXPOSED SUPPLY PIPE 6" ELECTRIC OPEN/CLOSE VAM‐EM21 480VAC CONSOLE 0.75 DXF‐FWS‐RTK01 MP510 BALL VALVE SORTING AREA, RECOVERY TANK SUPPLY 4" MANUAL OPEN/CLOSE DXF‐FWS‐RTK02 MP510 BALL VALVE SORTING AREA, RECOVERY TANK DRAIN 4" MANUAL OPEN/CLOSE DXF‐FWS‐RTK03 MP510 BALL VALVE SORTING AREA, RECOVERY TANK OVERFLOW 4" MANUAL OPEN/CLOSE DXF‐FWS‐STB01 MP511 BALL VALVE SORTING AREA, FISH PIPE SUPPLY PIPE 1 4" MANUAL OPEN/CLOSE DXF‐FWS‐STB02 MP511 BALL VALVE SORTING AREA, FISH PIPE SUPPLY PIPE 2 4" MANUAL OPEN/CLOSE DXF‐FWS‐STB03 MP511 BALL VALVE SORTING AREA, FISH PIPE SUPPLY PIPE 3 4" MANUAL OPEN/CLOSE DXF‐FWS‐STB04 MP511 BALL VALVE SORTING AREA, FISH PIPE SUPPLY PIPE 4 4" MANUAL OPEN/CLOSE DXF‐FWS‐STB05 MP511 BALL VALVE SORTING AREA, FISH PIPE SUPPLY PIPE 5 4" MANUAL OPEN/CLOSE DXF‐FWS‐STB06 MP511 BALL VALVE SORTING AREA, IN LINE, TABLE FLUSHING SUPPLY PIPE 2" MANUAL OPEN/CLOSE DXF‐FWS‐STB07 MP511 BALL VALVE SORTING AREA, IN LINE, TABLE FLUSHING SUPPLY PIPE 2" MANUAL OPEN/CLOSE DXF‐FWS‐STB08 MP511 BALL VALVE SORTING AREA, IN LINE, TABLE FLUSHING SUPPLY PIPE 2" MANUAL OPEN/CLOSE DXF‐FWS‐STB09 MP511 BALL VALVE SORTING AREA, IN LINE, TABLE FLUSHING SUPPLY PIPE 2" MANUAL OPEN/CLOSE DXF‐FWS‐ANS01 MP511 BALL VALVE ANESTHETIC TANK, IN LINE, SUPPLY 3" MANUAL OPEN/CLOSE DXF‐FWS‐ANS02 MP511 BALL VALVE ANESTHETIC TANK, IN LINE, DRAIN TO RAIN GARDEN 3" MANUAL OPEN/CLOSE

DXF‐FWS‐TFS01 MP513 BALL VALVE TRUCK FILL STATION 6" MANUAL OPEN/CLOSE

DXF‐FWS‐CRH01 MP512 KNIFE GATE CONCRETE RACEWAY HEADER 30" ELECTRIC OPEN/CLOSE VAM‐EM22 480VAC YES 0.75 DXF‐FWS‐STS02 MP506 GATE SWITCHGATE AREA, EXPOSED SUPPLY FOR RTR 10" MANUAL MODULATING DXF‐FWS‐UWD03 SLIDE GATE EXISTING LADDER AREA SLIDE GATE 96" ELECTRIC MODULATING VAM‐EM23 480VAC YES 1

DXF‐FWS‐FMF01 M603 FLOW METER ENTRANCE AREA 48"

DXF‐FWS‐FMA01 M603 FLOW METER ENTRANCE AREA, VAULT 2 48"

DXF‐FWS‐AAV01 M603 AIR VALVE ENTRANCE AREA, VAULT 2 8"

DXF‐FWS‐OGH01 M603 GATE HOIST TAIL WATER

DXF‐FWS‐AWF01 M603 FLOW METER EXISTING LADDER AREA SLIDE GATE 48"

DXF‐FWS‐PRF01 M604 FLOW METER PRESORT AREA, OBSERV. PLATFORM, FALSE WEIR DRAIN 10" DXF‐FWS‐ANS03 MP513 BALL VALVE ANESTHETIC TANK, IN LINE, DRAIN TO RAIN GARDEN 3" MANUAL OPEN/CLOSE

VALVE AND ACTUATOR SCHEDULE

B

C

D

E

1 2 3 4 5 6

A

D

ES

IG

N

ED

B

Y:

D

AT

E:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

PL

O

T

SC

AL

E:

PL

O

T D

AT

E:

SI

ZE

FI

L E N

AM

E:

US Army Corps of Engineers

PORTLAND DISTRICT

SHEET

IDENTIFICATION

M-600

D

EX

TE

R

D

AM

A N

D R

ES

ER

VO

IR

AD

U

LT

F

IS

H

F

AC

IL

IT

Y U

PG

R

AD

E

G

EN

ER

AL

VA

LV

E

AN

D A

C

TU

AT

O

R

SC

H

ED

U

LE

EN

C

-D M

J.

G

IR

AL

T B.

F

IL

AN

/1

7/

W

N

R

D

AN

IE

L M

. J

EN

SE

N

P .E

/1

7/

1:

AN

SI

F

PO

R

TL

AN

D D

IS

TR

IC

T

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

PO

R

TL

AN

D , O

R

EG

O N

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

D

XF

1.

1_

M -6

.D

W G

GENERAL NOTES:

1. SEE M-001 FOR GENERAL MECHANICAL NOTES.

2. SEE MP AND MK SERIES SHEETS FOR DETAILS.

3. BALL VALVES INDICATED AS 6" OR LESS MUST BE PROVIDED AS A THREE PIECE VALVE

TO ENSURE FUTURE REPLACEMENT/REPAIR. CONTRACTOR MAY PROPOSE ALTERNATE

PIPE CONFIGURATION TO SUPPORT A STANDARD VALVE.

-2 3-

TA

BL

E U

PD

AT

E

TO

IN

C

O R

PO

R

AT

E

C H

AN

G

ES

A

N D

U

PD

AT

ES

IN

T

AG

S

AN

D

L O

C

AT

IO

N

S O

F

VA

LV

ES

File details come from the government source that posted it. Updated .