Drawings MK502_M-600_M-002_MQ501_AMDT 0004.pdf

PDF 632 KB Posted

Attached to
Dexter Adult Fish Facility Upgrades
Solicitation number
W9127N23R0005
Issued by

About this file

This federal solicitation is for construction services related to upgrades at the Dexter Adult Fish Facility. The solicitation seeks contractors to improve, replace, and add major features to the Dexter Fish Facility to meet criteria set by the National Marine Fisheries Service. Upgrades include work on the fish ladder, auxiliary water system diffusion chambers, and other areas. The period of performance is from March 2023 to November 2026. The estimated value of construction work is between $25 million to $100 million. The solicitation is unrestricted and open to all contractors. A 10% price evaluation preference will be given to offers from HUBZone small businesses. The relevant NAICS code is 237990 for other heavy and civil engineering construction, with a $39.5 million small business size standard. The issuing agency is the Department of the Army Corps of Engineers Engineering District Portland.

View the file

Other files

File Type Posted
Dexter Fish Facility W9127N23R0005 Amend 0005.pdf PDF
Dexter_Pre-Bid and Follow On Site Visit_Attendance List.pdf PDF
ProjectNet Inquiries and Responses - Dexter Fish Facilities.pdf PDF
Section 00 10 00 CLINS Structure AMDT 0004.pdf PDF
Drawings SR701_SR101_AMDT 0004.pdf PDF
DB Wage Rate OR20230057 01.06.2023_AMDT 0004.pdf PDF
Dexter Fish Facility W9127N23R0005 Amend 0004.pdf PDF
Spec 26 42 13.00 25_AMDT 0004.pdf PDF
Specs Attachment 1 - Submittal Register_AMDT 0004.pdf PDF
Drawings SK523_SK516-2_SK516_SK516-1_SK516-3_AMDT 0004.pdf PDF
Spec 33 61 13.19 25_AMDT 0004.pdf PDF
Spec 01 22 00.00 25_AMDT 0004.pdf PDF
Drawings CS103_CU105_CU201_CU102_CU103_AMDT 0004.pdf PDF
Clean Sol Package Drawings ELECTRICAL_AMDT 0003 Part4.pdf PDF
Clean Sol Package Drawings MECHANICAL_AMDT 0003.pdf PDF
Dexter W9127N23R0005 Clean Solicitation Package.pdf PDF
Clean Sol Package Drawings ELECTRICAL_AMDT 0003 Part1.pdf PDF
Clean Sol Package Drawings STRUCTURAL_AMDT 0003 Set 5 (SP).pdf PDF
Clean Sol Package Drawings ELECTRICAL_AMDT 0003 Part2.pdf PDF
Clean Sol Package Drawings GENERAL_AMDT 0003.pdf PDF
Clean Sol Package Drawings STRUCTURAL_AMDT 0003 Set 3 (SL-SN).pdf PDF
Clean Sol Package Drawings ELECTRICAL_AMDT 0003 Part3.pdf PDF
Clean Sol Package Drawings LANDSCAPE_AMDT 0003.pdf PDF
Clean Sol Package Drawings STRUCTURAL_AMDT 0003 Set 4 (SO-ST).pdf PDF
Clean Sol Package Drawings STRUCTURAL_AMDT 0003 Set 1 (S-SJ) - Part2.pdf PDF
Clean Sol Package Drawings STRUCTURAL_AMDT 0003 Set 2 (SK).pdf PDF
Clean Sol Package Drawings STRUCTURAL_AMDT 0003 Set 1 (S-SJ) - Part1.pdf PDF
Dexter Fish Facility W9127N23R0005 Amend 0003.pdf PDF
Clean Sol Package Drawings CIVIL_AMDT 0003.pdf PDF
STRUCTURES_AMDT 0002.pdf PDF
CU502_19DEC22_AMDT 0002.pdf PDF
M-600_AMDT 0002.pdf PDF
MK502_AMDT 0002.pdf PDF
E-603_EL602_EN602_M-601_ML524_AMDT 0002.pdf PDF
MZ101_23DEC22_AMDT 0002.pdf PDF
MW101-MW501-MW502_AMDT 0002.pdf PDF
MY103_AMDT0002.pdf PDF
STRUCTURES_AMDT 0002.pdf PDF
CD501_19DEC22_AMDT 0002.pdf PDF
Dexter Amendment 0002 Spec Changes Package.pdf PDF
W9127N23R0005 Amendment 0002 12.29.22.pdf PDF
Dexter Road Photo Tour.pdf PDF
Dexter Fish Facility Photo Tour.pdf PDF
DXF1.101_ES101-A2 (Electrical_Update_Amend0002).pdf PDF
Attach 8 - Dexter GBR Update Amend0002.pdf PDF
DXF1.101_DEXTER FF UPGRADE_STRUCTURAL UPDATE AMEND 0002.pdf PDF
Attachment 10 - DSL Removal Fill Permit.pdf PDF
W9127N23R0005-Amendment 0001 12.5.2022.pdf PDF
Specs 01 22 00.00 25 M&P Amend 0001.pdf PDF
Site Visit Attendance Sheet - Dexter.pdf PDF
Show 40 more

Latest 50 of 71 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

B

C

D

E

1 2 3 4 5 6

A

D

ES

IG

N

ED

B

Y:

D

AT

E:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

PL

O

T

SC

AL

E:

PL

O

T D

AT

E:

SI

ZE

FI

L E N

AM

E:

US Army Corps of Engineers

PORTLAND DISTRICT

SHEET

IDENTIFICATION

MQ501

D

EX

TE

R

D

AM

A N

D R

ES

ER

VO

IR

AD

U

LT

F

IS

H

F

AC

IL

IT

Y U

PG

R

AD

E

FA

IL

IT

Y D

IS

C

H

AR

G E

SY

ST

EM

S

R

ET

U R

N T

O R

IV

ER

P

IP

JO

SE

PH

V

. G

IR

AL

T

J.

G

IR

AL

T W

H

IT

EH

EA

D

/1

7/

W

N

R

D

AN

IE

L M

. J

EN

SE

N

P .E

/1

7/

1:

AN

SI

F

PO

R

TL

AN

D D

IS

TR

IC

T

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

PO

R

TL

AN

D , O

R

EG

O N

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

D

XF

-1

.1

_M Q

1.

D W

G

RETURN TO RIVER PIPE

PRESORT POOL

SORT AREA

SCALE: 1"= 10'

10' 0 10'5' 0 5' 10'

SCALE: 1

8"= 1'-0"

FACILITY WATER DISCHARGE

RETURN TO RIVER DISCHARGE

N: 831251.26 E: 4313393.18

EL. 644.35'

MP102

RETURN TO RIVER PIPE NORTH

1/8" = 1'

MP102

RETURN TO RIVER PIPE SOUTH

1" = 10'

10'-117 8"

NOTES:

1. SEE GENERAL NOTES, SHEET M-001 AND M-002.

SEE ALSO MN 514 FOR PIPE NOMENCLATURE

2. PIPE ELEVATIONS ARE PROVIDED AT PIPE

CENTERLINE. AT BELL AND SPIGOT LOCATIONS,

MEASUREMENTS TAKEN AT APPROXIMATE GASKET

LOCATION. SOME BELL AND SPIGOT LOCATIONS ARE

OMITTED; ADJUST SUPPORT LOCATIONS AS

REQUIRED TO ACCOUNT FOR ADDITIONAL BELL AND

SPIGOT LOCATIONS.

'-5

8"

67'-15 8"

'-6

10" GATE VALVE

(DXF-FWS-STS02)

RECOVERY TANK FLANGE

N: 831553.62 E: 4313321.70

EL. 664.81'

FLANGE

N: 831544.87 E: 4313318.86

EL. 663.84'

FLUME SWITCHGATE FLANGE

N: 831540.55 E: 4313327.73

EL. 667.05'

RTR-FS-1 FLANGE

N: 831534.73 E: 4313318.03

EL. 665.96'

10" FLANGE

N: 831541.80 E: 4313319.26

EL. 659.13'

45 ELBOW TYP 2

10" X 16" CONCENTRIC

REDUCER

18" X 10" CONCENTRIC

REDUCER

RTR-RT-3 FLANGE

N: 831528.08 E: 4313312.31

EL. 661.63'

RTR-RT-3 FLANGE

N: 831527.74 E: 4313313.21

EL. 663.39'

RTR-RT-3 FLANGE

N: 831520.01 E: 4313309.72

EL. 661.36'

RTR-RT-4 / 5 CONNECTION

N: 831498.54 E: 4313302.69

EL. 660.46'

SEE NOTE 2

RTR-FS-2 / 3 CONNECTION

N: 831495.69 E: 4313305.81

EL. 662.66'

SEE NOTE 2

RTR-RT-5 / 6 CONNECTION

N: 831485.10 E: 4313308.18

EL. 659.78'

SEE NOTE 2

RTR-FS-3 / 4 CONNECTION

N: 831482.62 E: 4313310.91

EL. 661.34'

SEE NOTE 2

RTR-RT-6 / RTR-U-1 FLANGE

N: 831458.25 E: 4313368.89

EL. 657.82'

RTR-U-1 / FS-4 FLANGE

N: 831457.16 E: 4313368.46

EL. 659.49'

SEE NOTE 2

RTR-U-1 / RTR-U-2 FLANGE

N: 831454.80 E: 4313376.67

EL. 657.57'

RTR-U-2 / 3 CONNECTION

N: 831440.49 E: 4313384.50

EL. 656.99'

SEE NOTE 2

RTR-U-3 / 4 CONNECTION

N: 831353.47 E: 4313355.89

EL. 654.89'

SEE NOTE 2

RTR-U-4 / 5 CONNECTION

N: 831339.81 E: 4313361.84

EL. 653.85'

SEE NOTE 2

R7'-6"

R10'-0"

R10'-0"

R10'-0"

RTR-U-5 / 6 CONNECTION

N: 831313.14 E: 4313422.39

EL. 649.02'

SEE NOTE 2

RTR-U-6 / 7 CONNECTION

N: 831300.45 E: 4313428.81

EL. 647.85'

SEE NOTE 2

RTR-U-8 FLANGE

N: 831253.53 E: 4313413.35

EL. 645.49'

A

D

IT

IO

N

/C O

R R

EC

TI

O N

S O

F N

O

TE

S

AN

D E

LE

VA

TI

O

N S

- R

EV

IS

ED

IN

A

C C

O R

D

AN

C E

W

IT

H A

M D

T

J

BJ

F

MARK SHEET DESCRIPTION LOCATION SIZE ACTUATOR SERVICE ACTUATOR VOLTAGE SCADA HP

DXF‐FWS‐EDC01 MK501 SLIDE GATE ENTRANCE AREA, TAILRACE DISCHARGE 78" ELECTRIC MODULATING VAM‐EM1 480VAC YES 5 DXF‐FWS‐ADC01 MK503 BALL VALVE ENTRANCE AREA, VAULT 2 48" ELECTRIC MODULATING VAM‐EM2 480VAC YES 1 DXF‐FWS‐ADC02 MK503 BALL VALVE ENTRANCE AREA, VAULT 2 48" ELECTRIC MODULATING VAM‐EM3 480VAC YES 1 DXF‐FWS‐AWS01A MK503 SLIDE GATE ENTRANCE AREA, DIFFUSER CHAMBER 1 48" ELECTRIC OPEN/CLOSE VAM‐EM4 480VAC YES 1.5 DXF‐FWS‐AWS01B MK503 SLIDE GATE ENTRANCE AREA, DIFFUSER CHAMBER 1 48" ELECTRIC OPEN/CLOSE VAM‐EM5 480VAC YES 1.5 DXF‐FWS‐AWS02 MK503 SLIDE GATE ENTRANCE AREA, DIFFUSER CHAMBER 2 36" ELECTRIC OPEN/CLOSE VAM‐EM6 480VAC YES 0.33 DXF‐FWS‐AWS03 MK503 SLIDE GATE ENTRANCE AREA, DIFFUSER CHAMBER 3 36" ELECTRIC OPEN/CLOSE VAM‐EM7 480VAC YES 0.33 DXF‐FWS‐AWS04 MK503 SLIDE GATE ENTRANCE AREA, DIFFUSER CHAMBER 4 36" ELECTRIC OPEN/CLOSE VAM‐EM8 480VAC YES 0.33 DXF‐FWS‐AWS05 MK503 SLIDE GATE ENTRANCE AREA, DIFFUSER CHAMBER 5 36" ELECTRIC OPEN/CLOSE VAM‐EM9 480VAC YES 0.33 DXF‐FWS‐AWS06 MK503 SLIDE GATE ENTRANCE AREA, DIFFUSER CHAMBER 6 36" ELECTRIC OPEN/CLOSE VAM‐EM10 480VAC YES 0.33 DXF‐FWS‐APH01 MP501 GATE ASPHALT POND HEADER, SURFACE PAD 12" ELECTRIC OPEN/CLOSE VAM‐EM11 480VAC YES 0.33

DXF‐FWS‐APD02 MP501 GATE ASPHALT POND DIFFUSER, MANHOLE 12" MANUAL OPEN/CLOSE

DXF‐FWS‐PSS01 MP503 BUTTERFLY PRESORT AREA, VAULT 3 30" ELECTRIC MODULATING VAM‐EM12 480VAC YES 1 DXF‐FWS‐PSS02 MP503 BUTTERFLY PRESORT AREA, VAULT 4 30" ELECTRIC MODULATING VAM‐EM13 480VAC YES 1 DXF‐FWS‐PRE01 MP504 BUTTERFLY PRESORT AREA, PLATFORM, EXPOSED, FLUME SUPPLY 6" ELECTRIC MODULATING VAM‐EM14 480VAC PSCC 0.75 DXF‐FWS‐PRE02 MP504 BUTTERFLY PRESORT AREA, OBSERV. PLATFORM, IN LINE EXPOSED, FALSE WEIR SUPPLY 10" ELECTRIC OPEN/CLOSE VAM‐EM15 480VAC PSCC 0.75 DXF‐FWS‐PRE03 MP504 BUTTERFLY PRESORT AREA, OBSERV. PLATFORM, FALSE WEIR DRAIN 6" MANUAL OPEN/CLOSE DXF‐FWS‐PRE04 MP503 BALL VALVE PRESORT AREA, VAULT 4, BRAIL PIT DRAIN, T‐HANDLE OPERATOR 2.5" MANUAL OPEN/CLOSE DXF‐FWS‐PRE05 MP503 BALL VALVE PRESORT AREA, VAULT 3, POOL DRAIN, T‐HANDLE OPERATOR 6" MANUAL OPEN/CLOSE DXF‐FWS‐UWI02 MP506 GATE EXISTING LADDER AREA‐ SURFACE SUPPORTED CONCRETE PAD 30" ELECTRIC OPEN/CLOSE VAM‐EM16 480VAC YES 1 DXF‐FWS‐UWD01 MP506 BALL VALVE EXISTING LADDER AREA‐ SURFACE SUPPORTED CONCRETE PAD 12" ELECTRIC MODULATING VAM‐EM17 480VAC YES 0.33 DXF‐FWS‐UWD02 MP506 BALL VALVE EXISTING LADDER AREA‐ SURFACE SUPPORTED CONCRETE PAD 24" ELECTRIC MODULATING VAM‐EM18 480VAC YES 0.33 DXF‐FWS‐PSP01 MP507 BUTTERFLY EXISTING LADDER AREA, VAULT 5, OPERATOR STAND 18" MANUAL OPEN/CLOSE DXF‐FWS‐PST01 MP508 BUTTERFLY EXISTING LADDER AREA, VAULT 6, REMOVABLE TEE HANDLE 6" MANUAL OPEN/CLOSE DXF‐FWS‐PST02 MP508 BUTTERFLY EXISTING LADDER AREA, VAULT 6, REMOVABLE TEE HANDLE 6" MANUAL OPEN/CLOSE DXF‐FWS‐PST03 MP508 BUTTERFLY EXISTING LADDER AREA, VAULT 6, REMOVABLE TEE HANDLE 6" MANUAL OPEN/CLOSE DXF‐FWS‐PST04 MP508 BUTTERFLY EXISTING LADDER AREA, VAULT 6, REMOVABLE TEE HANDLE 6" MANUAL OPEN/CLOSE DXF‐FWS‐PST05 MP508 BUTTERFLY EXISTING LADDER AREA, VAULT 6, REMOVABLE TEE HANDLE 6" MANUAL OPEN/CLOSE DXF‐FWS‐PST06 MP508 BUTTERFLY EXISTING LADDER AREA, VAULT 6, REMOVABLE TEE HANDLE 6" MANUAL OPEN/CLOSE DXF‐FWS‐PST07 MP508 BUTTERFLY EXISTING LADDER AREA, VAULT 6, REMOVABLE TEE HANDLE 6" MANUAL OPEN/CLOSE DXF‐FWS‐PST08 MP508 BUTTERFLY EXISTING LADDER AREA, VAULT 6, REMOVABLE TEE HANDLE 6" MANUAL OPEN/CLOSE DXF‐FWS‐PST09 MP508 BUTTERFLY EXISTING LADDER AREA, VAULT 6, REMOVABLE TEE HANDLE 6" MANUAL OPEN/CLOSE DXF‐FWS‐PST10 MP508 BUTTERFLY EXISTING LADDER AREA, VAULT 6, REMOVABLE TEE HANDLE 6" MANUAL OPEN/CLOSE DXF‐FWS‐STI01 MP511 BUTTERFLY SWITCHGATE AREA, VAULT 7, OPERATOR STAND, MAIN LINE ISOLATE 18" MANUAL OPEN/CLOSE DXF‐FWS‐STS01 MP511 BUTTERFLY SWITCHGATE AREA, VAULT 7, OPERATOR STAND, SORT AREA ISOLATE 16" MANUAL OPEN/CLOSE DXF‐FWS‐SGI01 MP511 BUTTERFLY SWITCHGATE AREA, VAULT 7, OPERATOR STAND, RTR/SWITCH ISOLATE 18" MANUAL OPEN/CLOSE DXF‐FWS‐PSF01 MP511 BUTTERFLY SWITCHGATE AREA, IN LINE WITH EXPOSED SUPPLY PIPE, RTR SUPPLY 6" ELECTRIC OPEN/CLOSE VAM‐EM19 480VAC CONSOLE 0.75 DXF‐FWS‐PSF02 MP511 BUTTERFLY SWITCHGATE AREA, IN LINE WITH EXPOSED SUPPLY PIPE, POOL 1 FISH PIPE SUPPLY 6" ELECTRIC OPEN/CLOSE VAM‐EM20 480VAC CONSOLE 0.75 DXF‐FWS‐PSF03 MP511 BUTTERFLY SWITCHGATE AREA, IN LINE WITH EXPOSED SUPPLY PIPE, POOL 2 FISH PIPE SUPPLY 6" ELECTRIC OPEN/CLOSE VAM‐EM21 480VAC CONSOLE 0.75 DXF‐FWS‐RTK01 MP511 BALL VALVE SORTING AREA, RECOVERY TANK SUPPLY 4" MANUAL OPEN/CLOSE DXF‐FWS‐RTK02 MP511 BALL VALVE SORTING AREA, RECOVERY TANK DRAIN 4" MANUAL OPEN/CLOSE DXF‐FWS‐RTK03 MP511 BALL VALVE SORTING AREA, RECOVERY TANK OVERFLOW 4" MANUAL OPEN/CLOSE DXF‐FWS‐RTK04 MP514 BALL VALVE SORTING AREA, RECOVERY TANK, FISH PIPE SUPPLY 4" MANUAL OPEN/CLOSE DXF‐FWS‐RTK05 MP514 BALL VALVE SORTING AREA, RECOVERY TANK, RAMP SPRAY NOZZLE SUPPLY 1.5" MANUAL OPEN/CLOSE DXF‐FWS‐STB01 MP513 BALL VALVE SORTING AREA, FISH PIPE SUPPLY PIPE 1 4" MANUAL OPEN/CLOSE DXF‐FWS‐STB02 MP513 BALL VALVE SORTING AREA, FISH PIPE SUPPLY PIPE 2 4" MANUAL OPEN/CLOSE DXF‐FWS‐STB03 MP513 BALL VALVE SORTING AREA, FISH PIPE SUPPLY PIPE 3 4" MANUAL OPEN/CLOSE DXF‐FWS‐STB04 MP513 BALL VALVE SORTING AREA, FISH PIPE SUPPLY PIPE 4 4" MANUAL OPEN/CLOSE DXF‐FWS‐STB05 MP513 BALL VALVE SORTING AREA, FISH PIPE SUPPLY PIPE 5 4" MANUAL OPEN/CLOSE DXF‐FWS‐STB06 MP513 BALL VALVE SORTING AREA, IN LINE, TABLE FLUSHING SUPPLY PIPE 2" MANUAL OPEN/CLOSE DXF‐FWS‐STB07 MP513 BALL VALVE SORTING AREA, IN LINE, TABLE FLUSHING SUPPLY PIPE 2" MANUAL OPEN/CLOSE DXF‐FWS‐STB08 MP513 BALL VALVE SORTING AREA, IN LINE, TABLE FLUSHING SUPPLY PIPE 2" MANUAL OPEN/CLOSE DXF‐FWS‐STB09 MP513 BALL VALVE SORTING AREA, IN LINE, TABLE FLUSHING SUPPLY PIPE 2" MANUAL OPEN/CLOSE DXF‐FWS‐ANS01 MP513 BALL VALVE ANESTHETIC TANK, IN LINE, SUPPLY 3" MANUAL OPEN/CLOSE DXF‐FWS‐ANS02 MP513 BALL VALVE ANESTHETIC TANK, IN LINE, DRAIN TO RAIN GARDEN 3" MANUAL OPEN/CLOSE DXF‐FWS‐ANS03 MP513 BALL VALVE ANESTHETIC TANK, IN LINE, OVERFLOW DRAIN TO RAIN GARDEN 3" MANUAL OPEN/CLOSE

DXF‐FWS‐TFS01 MP514 BALL VALVE TRUCK FILL STATION 6" MANUAL OPEN/CLOSE

DXF‐FWS‐CRH01 MP512 KNIFE GATE CONCRETE RACEWAY HEADER 30" ELECTRIC OPEN/CLOSE VAM‐EM22 480VAC YES 0.75 DXF‐FWS‐STS02 MP511 GATE SWITCHGATE AREA, EXPOSED SUPPLY FOR RTR 10" MANUAL MODULATING DXF‐FWS‐UWD03 SK516‐3 SLIDE GATE EXISTING LADDER AREA SLIDE GATE 96" ELECTRIC MODULATING VAM‐EM23 480VAC YES 1

DXF‐FWS‐AAV01 M603 AIR VALVE ENTRANCE AREA, VAULT 2, DECK AREA 8"

DXF‐FWS‐FH01 MP514 HYDRANT RESIDENCE ROADWAY 6" MANUAL OPEN/CLOSE

VALVE AND ACTUATOR SCHEDULE

B

C

D

E

1 2 3 4 5 6

A

D

ES

IG

N

ED

B

Y:

D

AT

E:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

PL

O

T

SC

AL

E:

PL

O

T D

AT

E:

SI

ZE

FI

L E N

AM

E:

US Army Corps of Engineers

PORTLAND DISTRICT

SHEET

IDENTIFICATION

M-600

D

EX

TE

R

D

AM

A N

D R

ES

ER

VO

IR

AD

U

LT

F

IS

H

F

AC

IL

IT

Y U

PG

R

AD

E

G

EN

ER

AL

VA

LV

E

AN

D A

C

TU

AT

O

R

SC

H

ED

U

LE

EN

C

-D M

J.

G

IR

AL

T B.

FI

LA

N

/0

4/

W

N

R

D

AN

IE

L

M . J

EN

SE

N P

.E

/0

4/

1:

AN

SI

F

PO

R

TL

AN

D D

IS

TR

IC

T

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

PO

R

TL

AN

D , O

R

EG

O N

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

D

XF

1.

1_

M -6

.D

W G

GENERAL NOTES:

1. SEE M-001 FOR GENERAL MECHANICAL NOTES.

2. SEE MP, MK, AND SK SERIES SHEETS FOR DETAILS.

3. BALL VALVES INDICATED AS 6" OR LESS MUST BE PROVIDED AS A THREE PIECE VALVE

TO ENSURE FUTURE REPLACEMENT/REPAIR. CONTRACTOR MAY PROPOSE ALTERNATE

PIPE CONFIGURATION TO SUPPORT A STANDARD VALVE.

-2 3-

TA

BL

E U

PD

AT

E

TO

IN

C

O R

PO

R

AT

E

C H

AN

G

ES

A

N D

U

PD

AT

ES

IN

T

AG

S

AN

D

L O

C

AT

IO

N

S O

F

VA

LV

ES

U

PD

AT

ED

S

C H

ED

U

LE

F

O R

D

XF

-F W

S- U

W D

C O

R R

EC

TE

D

IN

A C

C O

R D

AN

C

E W

IT

H

A M

D T

-0

4-

U

PD

AT

ED

IN

A

C C

O R

D

AN

C E

W

IT

H A

M D

T

4, S

C H

ED

U

LE

IS

U

PD

AT

ED

F R

O M

A M

D T

-1 3-

2 3

D

E

1 2 3 4 5 6

A

D

ES

IG

N

ED

B

Y:

D

AT

E:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

PL

O

T

SC

AL

E:

PL

O

T D

AT

E:

SI

ZE

FI

L E N

AM

E:

US Army Corps of Engineers

PORTLAND DISTRICT

SHEET

IDENTIFICATION

M-002

D

EX

TE

R

D

AM

A N

D R

ES

ER

VO

IR

AD

U

LT

F

IS

H

F

AC

IL

IT

Y U

PG

R

AD

E

G

EN

ER

AL

PI

PE

N O

TE

S

EN

C

-D M

J.

G

IR

AL

T B.

FI

LA

N

/0

4/

W

N

R

D

AN

IE

L

M . J

EN

SE

N P

.E

/0

4/

1:

AN

SI

F

PO

R

TL

AN

D D

IS

TR

IC

T

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

PO

R

TL

AN

D , O

R

EG

O N

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

D

XF

1.

1_

M -0

.D

W G

K

PIPING DESIGNATION

INDICATES PIPE

SIZE IN INCHES

INDICATES PIPE SERVICE WHEN SHOWN

(SEE ABBREVIATIONS BELOW)

INDICATES PIPE MATL

(SEE ABBREVS BELOW)

DOUBLE LINE SINGLE LINE

WELD JOINT

FLANGED JOINT

FLANGED COUPLING ADAPTER

FLEXIBLE COUPLING

FLEXIBLE COUPLING

WITH THRUST TIES

CONCENTRIC REDUCER

ECCENTRIC REDUCER

FLANGED BUTTERFLY VALVE

GATE VALVE

KNIFE GATE VALVE

MISCELLANEOUS PIPING SYMBOLS

AIR VENT (MANUAL)

3" - V 400

CONTROL VALVES

MANUAL VALVES AND CHECK VALVES

VALVE SYMBOLS

GATE

BUTTERFLY

GLOBE

BALL

ECCENTRIC PLUG

SEATING PORT

PLUG OR COCK

NEEDLE

SWING CHECK

BALL CHECK

PRESSURE RELIEF

AIR VENT (AUTO)

SOLENOID VALVE

IMPLIED BY INDICATED FLOW PATTERN.

INDICATE FLOW PATTERN. SEATING PORTS ARE

APPROPRIATE VALVE SYMBOL SHOWN). ARROWS

(GLOBE VALVE SHOWN. FOR OTHER VALVE TYPES,

MULTI-PORT VALVE

REGULATED SIDE

PRESSURE CONTROL

GAUGE WITH COCK

THERMOMETER

FLOW SWITCH

X = NO. SHOWN IN SPECS

FLOW METER

PRESSURE SWITCH

STRAINER

FLEXIBLE HOSE

VALVE TYPE, SEE

SPECIFICATIONS

VALVE DESIGNATION

SIZE OF VALVE

ACTUATOR SYMBOL

FLOW DIRECTION

FLOW DIRECTION

VALVE SYMBOL

VALVE DESIGNATION

PLAN VIEW

GATE SYMBOLS

SPRING-OPPOSED, SINGLE OR

DOUBLE ACTING

SINGLE OR DOUBLE ACTING

ACTUATED BY ONE INPUT

HYDRAULIC

SOLENOID

ELECTRO HYDRAULIC

ELECTRIC MOTOR

PNEUMATIC CYLINDER

PNEUMATIC DIAPHRAGM

ACTUATOR SYMBOLS

HEAT TRACED AND INSULATED PIPE

PNEUMATIC

CENTRIFUGAL

VERTICAL PROPELLER

AXIAL FLOW

PUMP SYMBOLS

HOSE VALVE (HV- X) OR

(V-X) X = NO. IN SPECS

INTAKE SCREEN

18-D-STP

DIAPHRAGM, DIFFERENTIAL

PRESSURE

STOP LOG

FLAP

SLUICE

SHEAR

FABRICATED SLIDE

X

FS

FM

PS

M

S

K

S

H

M

P

1. LAY PIPE TO UNIFORM GRADE BETWEEN INDICATED ELEVATION

POINTS.

2. SIZE OF FITTINGS SHOWN ON PLANS SHALL CORRESPOND TO

ADJACENT STRAIGHT RUN OF PIPE, UNLESS OTHERWISE INDICATED.

TYPE OF JOINT AND FITTING MATERIAL SHALL BE THE SAME AS

SHOWN FOR ADJACENT STRAIGHT RUN OF PIPE.

3. LOCATION AND NUMBER OF PIPE HANGERS AND PIPE SUPPORTS SHOWN IS

ONLY APPROXIMATE. FINAL SUPPORT REQUIREMENTS SHALL BE DETERMINED

IN THE FIELD AND/OR DETAILED ON SHOP DRAWINGS, AND APPROVED BY THE

ENGINEER PRIOR TO INSTALLATION. MAXIMUM SPACING SHALL BE AS SPECIFIED.

4. ALL JOINTS SHALL BE WATERTIGHT.

5. SYMBOLS, LEGENDS, AND PIPE USE IDENTIFICATIONS SHOWN SHALL

BE FOLLOWED THROUGHOUT THE PLANS, WHEREVER APPLICABLE.

ALL OF THE VARIOUS PIPING APPLICATIONS ARE NOT NECESSARILY

USED IN THE PROJECT.

6. NUMBER AND LOCATION OF UNIONS SHOWN ON PLANS IS ONLY

APPROXIMATE. PROVIDE ALL UNIONS NECESSARY TO FACILITATE

CONVENIENT REMOVAL OF VALVES AND MECHANICAL EQUIPMENT.

7. HYDRAULIC FLUID SYSTEMS ARE DESIGNED BASED ON THE STANDARD SYMBOLOGY

DEFINED IN STANDARD ISO 1219, FLUID POWER SYSTEMS AND COMPONENTS.

8. EXPOSED PIPE AND FITTINGS, ABOVE GRADE AND EXPOSED TO ATMOSPHERE, MAY

BE STAINLESS STEEL OR CARBON STEEL WITH COATING SYSTEM NO 29.

UNLESS OTHERWISE INDICATED. SEE SPECIFICATION 09 97 02.00 25.

BURIED PIPE AND FITTINGS MUST BE CARBON STEEL WITH COATING SYSTEM NO. 29.

UNLESS OTHERWISE INDICATED. SEE SPECIFICATION 09 97 02.00 25.

INTERIOR AND EXTERIOR SURFACES MUST RECEIVE A COATING SYSTEM. USE

STAINLESS STEEL PIPE WHEN INTERIOR COATING SYSTEM CANNOT BE APPLIED.

GALVANIZING IS NOT ACCEPTABLE. COATING SYSTEM FOR BURIED APPLICATION

REQUIRES MFR RECOMMENDED WRAP. BURIED PIPE MAY BE SUPPLIED AS HDPE,

UNLESS OTHERWISE INDICATED. SEE SPECIFICATIONS 40 05 13.00 25 AND 40 05 13.96 25.

9. PIPING EMBEDDED IN CONCRETE MUST BE STAINLESS STEEL OR CARBON STEEL WITH

COATING SYSTEM NO. 29. COATING SYSTEM REQUIREMENTS FOR BURIED APPLICATION

MUST BE USED. PIPING EXPOSED IN VAULTS

MAY BE STAINLESS STEEL OR CARBON STEEL WITH COATING SYSTEM NO. 29.

10. TRANSITIONS BETWEEN STEEL AND STAINLESS STEEL SHALL OCCUR

WHILE PIPE IS BURIED. DISSIMILAR METAL TRANSITIONS SHALL HAVE

ISOLATION PER THE SPECIFICATION.

11. SEE SPECIFICATIONS FOR DETAILS REGARDING MATERIAL, FITTING,

COATING, AND INSTALLATION REQUIREMENTS.

12. ALL ELBOWS SHALL BE TRADITIONALLY DEFINED LONG RADIUS SMOOTH WALL

90° ELBOWS UNLESS OTHERWISE DEFINED. MITERED JOINTS ARE NOT ACCEPTABLE.

13. VALVES SHALL BE LABELED ACCORDING TO SPECIFICATIONS PRIOR TO

INSTALLATION.

14. UNLESS OTHERWISE NOTED, MECHANICAL FASTENERS SHALL BE 18-8

OR 300 SERIES STAINLESS STEEL AND INSTALLED USING AN

APPROVED ANTI-GALLING COMPOUND.

15. ALL PIPE LENGTHS ARE APPROXIMATE AND SHALL BE VERIFIED BY

CONTRACTOR.

16. REDUCERS SHALL BE OF THE CONICAL TYPE, PER ASME B31.3.

STEEL PIPE

POLYVINYL CHLORIDE

STAINLESS STEEL

DUCTILE IRON

STP

SST

PVC

HIGH DENSITY POLYETHYLENE

DI

HDPE

GSP

COP

PIPE MATERIAL

GALVANIZED STEEL PIPE

COPPER

FWDS

HF

WS

V

FWS

FT

D

FISH TRANSFER

HYDRAULIC FLUID

FACILITY WATER DISTRIBUTION SYSTEM

FOREBAY WATER SUPPLY

WASHDOWN SYSTEM

VENT

TANKER FILL

DRAIN

SERVICE ABBREVIATION FOR PIPING

CA COMPRESSED AIR

TF

GENERAL PIPING NOTES

MECHANICAL LEGEND AND NOTES

GENERAL PIPE DESIGN INFORMATION

1. FLOW VELOCITIES MAY NOT EXCEED 20 FT/S.

2. A TOTAL MAXIMUM PIPE FLOW VIA EXISTING POWERHOUSE CONNECTION IS 239

CFS. A MAXIMUM FLOW OF 139.2 CFS WILL BE DELIVERED TO THE AUXILIARY WATER

SYSTEM VIA POWER HOUSE SUPPLY DIVERSION.

3. FOR PIPE INDICATED AS 48" DIAMETER, MINIMUM INTERNAL DIAMETER IS 47.25"

PLUS NOMINAL COATING THICKNESS. ACCEPTABLE PIPING SYSTEMS MAY NEED TO

BE PROVIDED AT LARGER DIAMETERS. UP TO 60" DIAMETER, IN SELECTED AREAS,

MAY BE ACCEPTABLE BY APPROVED SUBMITTAL.

4. BURIED FERROUS PIPING SYSTEMS MUST BE SUPPLIED WITH A CATHODIC

PROTECTION SYSTEM.

5. FERROUS PIPING SYSTEMS MUST BE SUPPLIED WITH A THERMOPLASTIC COATING

SYSTEM. IT MUST BE APPLIED INTERIOR AND EXTERIOR SURFACES, TO INCLUDE

WELDED FLANGES.

6. EXPOSED FERROUS PIPE MUST INCLUDE AN EXTERNAL POLYURETHANE TOP

COATING, WRAP, MASTIC, OR OTHER APPROVED UV PROTECTION SYSTEM.

7. VAULT PENETRATIONS MUST BE PROVIDED WITH WATER TIGHT SEAL SYSTEM.

8. THRUST BLOCKS ARE REQUIRED.

9. AIR RELEASE COMBINATION VALVES MUST BE PLACED NEAR HIGH POINTS IN THE

WATER SUPPLY PIPE SYSTEM. PLACEMENT MUST OCCUR SO THAT PIPE CAN BE

DRAINED AND FILLED.

10. VALVE OPERATOR MUST BE INSTALLED ABOVE VAULT LID. OPERATOR MUST BE

ACCESSIBLE AND OPERABLE WITHOUT ENTERING THE VAULT.

-1

3 -

U

PD

AT

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

D T

, P

IP

E N

O

TE

S

AR

E

AM

EN

D

ED

D

E

1 2 3 4 5 6

A

D

ES

IG

N

ED

B

Y:

D

AT

E:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

PL

O

T

SC

AL

E:

PL

O

T D

AT

E:

SI

ZE

FI

L E N

AM

E:

US Army Corps of Engineers

PORTLAND DISTRICT

SHEET

IDENTIFICATION

MK502

D

EX

TE

R

D

AM

A N

D R

ES

ER

VO

IR

AD

U

LT

F

IS

H

F

AC

IL

IT

Y U

PG

R

AD

FI

SH

L

AD

D

ER

A

W S

D

IF

FU

SI

O N

C H

AM

BE

R

AW

S C

O N

N

EC

TI

O

N

PL

AN

V

IE

W

JO

SE

PH

V

. G

IR

AL

T

J.

G

IR

AL

T W

H

IT

EH

EA

D

/1

7/

W

N

R

IE

L M

. J

EN

SE

N

P .E

/1

7/

1:

AN

SI

F

PO

R

TL

AN

D D

IS

TR

IC

T

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

PO

R

TL

AN

D , O

R

EG

O N

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

D

XF

-1

.1

_M K5

.D

W G

SCALE:

AWS PIPING ISOMETRIC VIEW

NTS

30'20'10'05'

SCALE: 116"= 1'-0"

MP102

AWS PIPING PLAN VIEW

SCALE: 1/16"=1'-0"

A

MK504

B

MK504

NEW FWS CONNECTION TO EXISTING

48"Ø FACILITY WATER SUPPLY MADE

AT OUTSIDE POWERHOUSE WALL,

CL EL 643.82'

36"Ø AWS WATER RETURN PIPE

EMBEDDED IN AWS.

CL EL 641.57'

48"Ø ENTRANCE DIFFUSION CHAMBER HEADER PIPE,

SEE SHEET MK503 FOR DETAILS

CL EL 636.82'

VALVE VAULT 2 NOT SHOWN

48"Ø BALL VALVE AND

ACTUATOR. (2 EACH)

HOUSEKEEPING PAD 1

FOR 12"Ø SUPPLY

HEADER SHUT-OFF VALVE

NEW 12" ØCONNECTION TO

EXISTING 12" Ø ASPHALT POND

SUPPLY HEADER LINE,

CL EL 658.32'

NEW 12"Ø CONNECTION TO

EXISTING 12"Ø ASPHALT POND

DIFFUSER PIT SUPPLY LINE,

CL EL 642.45'

36"Ø AWS RETURN PIPE FROM

EXISTING FISH LADDER TO AWS

PIPE FOLLOWS EXISTING 48"Ø

FACILITY WATER SUPPLY PIPE

TRENCH, CL EL 648.98'

SEE SHEET MK504 FOR DETAILS

PRE-SORT AREA DRAIN LINE,

SEE SHEET MP505 FOR DETAILS

DETAIL 1: AWS INLET

SEE SR101 AND SR701

FOR STRUCTURAL DETAILS

EXISTING ASPHALT POND

FISH LADDER

SEE SE SERIES DRAWINGS

FOR STRUCTURAL DETAILS

ACCESS LADDER CROSSING

SEE SK SERIES DRAWING FOR

STRUCTURAL DETAILS

FISH LADDER ENTRANCE

AWS DIFFUSION CHAMBERS

SEE SE SERIES DRAWINGS

FOR STRUCTURAL DETAILS

FLOW TRANSITOR

VALVE VAULT NOT SHOWN

WASTE WATER COMBINTION AIR VALVE

PRESSURE TRANSDUCER

PRESSURE TRANSDUCER PIPELINE

D

EC

N O

TE

U

P D

AT

ED

T O

A C

C U

R

AT

EL

Y

R

EF

LE

C

T

IN

FO

R

M

AT

IO

N

O N

M

- R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

D T

8' -0

6'-21 2"

TRANSITION BEND TYPICAL

NOTES:

1. SEE SHEET M-001 FOR GENERAL MECHANICAL NOTES.

2. FLANGE MUST BE INSTALLED USING 18" THICK CHLOROPRENE

GASKET.

7' -11

BOLTED FLANGE

CONNECTION TO AWS PIPE

BOLT ASSEMBLIES

NOT SHOWN

(3/16) G

3/16 TYP

8" STAINLESS STEEL PLATE

PER ASTM A240, TYP.

3' -0

AW

S

IN

LE

T D

ET

AI

L

AD

D

ED

, S R

R

EF

U

PD

AT

ED

, N O

TE

S

AD

D

ED

R

EV

IS

ED

IN

A

C C

O R

D

AN

C E

W

IT

H A

M D

T

JA

N

8"

M G

W

BJ

F

GRIND FLANGE TO ALLOW

FITMENT WITH TRANSITION

36" STAINLESS STEEL

FLANGE PER AWWA,

CLASS D, TYP 2 PLACES

A

36" SCH. 40 PIPE

SEE SHEET SR701

DETAIL

SCALE:

- 1/4"=1'-0"

SECTION

SCALE:

A

- 1/4"=1-0"

G

CJP

BI_10054535_10050607_Dexter MQ501_AMDT 0004
BI_10055622_Dexter M-600_AMDT 0004
Drawing M-002_AMDT 0004
Drawing MK502_AMDT 0004

File details come from the government source that posted it. Updated .