B615_Final_Design_Plans_Aug_12_2019_Sheet_-164__of_191.pdf
PDF 2 MB Posted
- Solicitation number
- W9126G-19-B-3286
About this file
B615 Final Design Plans Sheet 164 of 191
View the file
Other files
Show 40 more
Latest 50 of 92 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S2
S2
S2 S2 S2 S2
S2
S2
S2
S2
S2
S2
S2
S2 S2
S2
D O
S O
S O
S O
S O
SC1
PP1
(L)
PP1
(L)
KEY
KEY
KEY
KEY KEY
S1
S1
PC8
PC8
SO1
OS5
OS6
OS10
OS5 OS5 OS5
OS5 OS5
OS5OS5
OS5
OS5
OS6
OS6
OS6
OS6 OS6
OS6
OS6OS6OS6OS6OS6OS6
OS6OS6
OS6OS6OS6
OS6
OS6
OS6
OS5
OS5
OS10
BR
BR
BR
BR
BR
BR
BR
BR BR
3a 3b
3a 3b
R
EE
EF
E7.2 E7.8
E
D
C
W1 W2 W3 W4 W5 W6 W7 W8 W9 W10 W11 W12 W13 W14 W15 W16 W17 W18
WA
WB
WC
WD
EA
EB
EC
ED
E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12
MECHANICAL
RECEPT.
WOMEN LOCKER
WOMEN
OPEN OFFICE
ELECTRICAL
JAN
SHOWERS
STORAGE
CORR.
C101
CORR.
C102
CORR.
C104
ELEV.
E1
MACHINE
MEN SHOWER
MENS
INSTRUMENT
STORAGE
CORR.
C108
INSTRUMENT
MAINTENANCE
GROUP
REHEARSAL 4
GROUP
REHEARSAL 3
GROUP
REHEARSAL 2
MECHANICAL /
ELECTRICAL
CORR.
C105
CORR.
C106
MEN LOCKER
COMM.
SUPPLY OFFICE
IND. PRACTICE
ROOMS
CORR.
C109
CORR.
C110
STORAGE
STORAGE
GROUP
REHEARSAL 1
L
B1E
B1 B2
B2 B2E
B2 B2
B2E B1E
B1 B1
B1E B1
B1
A1-2A1-2
A1-2
B1E B1
B1
A1-1
A1-1
A1-1 A1-1
J J
J J
J J
J J
J J
J J
J J
J J
J J
J J
J1E
J1
B1E
B1
B1E
B1
B2E
B2
B2
B2
B2
B2
B2
B2
B2E
A1-2
A1-2A1-2A1-2A1-2
A1-2A1-2A1-2A1-2A1-2A1-2
A1-2A1-2
J J J J1E
J1 J1
J1E J1
J1E J1
J1 J1
J1 J1E
J1 J1
J1 J1
J1E J1
J1 J1
J1 J1E
J1 J1E
J1 J1
B1
L
A1-1A1-1
A1-1
A1-1
A1-1
A1-1
A1-3
A1-3
A1-3
A1-3
A1-3
A1-3 A1-3 A1-3
A1-1
A1-1
A1-1
A1-1
A1-1
A1-1
A1-1
A1-1
A1-1
B2
A1-1 A1-1 A1-1
B2 B2E
A1-1 A1-1
A1-1 A1-1 A1-8 A1-8
A1-1
A1-1
A1-1
A1-1
J
JE
J
J
A1-13
A1-13
XD
XD XD
XD XD
XD
XD
XD
XD
XDXD
XD
XD
XD
@21' (TYP.)
A1-4
XC
XC
XC
XC
XC XC
A1-1
A1-1 X
X
X
X
X
A1-1
A1-1
1 1
1 1 1 1
MECH / ELECT
X A1-1
XC
DE
X
CORR.
C103
X A1-3
XC
CORR.
C107
STG
B2 B2
B2EB2
B2 B2
B2 X B2E B2
B2E
B2X J
J J
J A1-1
A1-1 A1-1
A1-1
B2
B2
X
B2E
B2 HE H
J1
J1
A1-1
A1-1 A1-1
A1-1 B2E
B2
A1-1 A1-1
A1-1 A1-1
A1-1A1-1A1-1
A1-1 A1-1 A1-1
A1-1
X2 B2 B2
X
A1-2 A1-2
A1-2
A1-2
A1-2A1-2A1-2
A1-2
B2E B2
B2
B2E
X
A1-5
J J
J J JE J
JE J J J
JJEJJJJE
A1-2A1-2
A1-2 A1-2A1-2
A1-2A1-2
A1-2A1-2
A1-2A1-2
A1-2A1-2
A1-2
A1-2
B2 B2E
A1-3A1-3
A1-3
A1-3 A1-3
A1-3 A1-3
A1-3
A1-3
A1-3 A1-3
A1-3
A1-3
A1-3
A1-6
A1-3
A1-3 B2E
B2
B2E B2
A1-3
B2E B2
B2E
B2
A1-3 A1-3
B2E
A1-3 A1-3 A1-3 A1-3 A1-3 A1-3
A1-3 A1-3 A1-3 A1-3 A1-3 A1-3 A1-3
A1-3A1-3A1-3A1-3A1-3A1-3
A1-3 A1-3 A1-3 A1-3 A1-3 A1-3 A1-3
A1-3
A1-3
A1-3
A1-3
A1-4
A1-3
XD A1-3
A1-4
A1-3
A1-4
A1-4
A1-4
A1-4
A2-8
A1-1
A2-8
A1-4
A2-8 A2-8 A2-8
A2-8
A2-8
A2-8
A1-3
J
JE
X
A1-3
A1-3
X
XD
A2-8
XD
XD3
A1-4
A1-4
@9'-6" @9'-6" @9'-6"XB XB
XB
@9'-6"
@9'-6"
@9'-6"
@8'-0"
@9'-6"
@9'-6"
@9'-6"
@9'-6"
H2 H2
X2
A1-3
X X
X
X
X a b a a b
A1-10
A1-11
A1-7
A1-7
A1-7
A1-12
A1-12
A1-12 a b a b b a b a
7 7 7
A1-6
A1-3
A1-3
A2-18 A2-18 A1-1
A2-18 A1-2 a b a b
A1-5
M a b
A1-3
R E
E
NI
GNELANOI
SS
E F
O R
S
TATE O
SAXETF
P
VISHAL R. BHAN
104552
NECI
L
SED
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
AUGUST 12, 2019
E-111
L
IG
H T
IN
G
F L O
O R
P L A
N
F
IR
S T
F L O
O R
R E
N O
V A
T
IO
N O
F B
U
IL
D
IN
G
V A
J
V A
J
V B
H A
N
A U
G U
S T
FINAL SUBMITTAL
K F
B
L D
G E
L E
C T
R
IC
A L
W G
B
1/8" = 1'-0"
1 LIGHTING FLOOR PLAN - FIRST FLOOR
NORTH
0' 8' 16'
GRAPHIC SCALE 1/8" = 1'-0"
4'
GENERAL NOTES
1. ALL FIXTURES TO BE nLIGHT ENABLED UNLESS NOTED OTHERWISE.
FIXTURES TO BE DAISY CHAINED TOGETHER VIA CAT5 LOOP (TYPICAL FOR
ALL SPACES).
2. REFER TO E-604 FOR LIGHTING FIXTURE SCHEDULE AND CONTROLS.
3. REFER TO E-607 FOR LIGHTING CONTROL LEGEND.
4. ALL ATTACHMENTS TO HISTORIC MASONRY WALL EXTERIOR AND
INTERIOR SURFACES SHALL BE IN MORTAR JOINTS. NO ATTACHMENTS
SHALL BE MADE WITHIN BRICK.
5. PENETRATIONS AT HISTORIC MASONRY WALLS SHALL BE COORDINATED
WITH HISTORIC ARCHITECT PRIOR TO WORK. PENETRATIONS SHALL
REMOVE WHOLE BRICKS. GROUT TO FILL PENETRATION SHALL BE LIME
BASED RESTORATION MORTAR.
6. REFER TO SHEETS E-606 AND E-607 FOR PROVIDING LOW VOLTAGE
nLIGHT SYSTEM WIRING FOR COMPLYING WITH ENERGY CODE AS
REQUIRED PART OF THIS CONTRACT.
NOTES BY SYMBOL " "
1. LIGHT FIXTURE TYPE "XD" SHALL BE SERVED VIA RELAY PANEL "RP8"
LOCATED IN ELECTRICAL ROOM. MOUNT FIXTURE AT 21'-0" AFF.
2. REFER TO SECOND FLOOR LIGHTING PLAN FOR LIGHTING AND CONTROLS
IN THIS AREA.
3. LIGHT FIXTURE TYPE "XD" SHALL BE SERVED VIA RELAY PANEL "RP8"
LOCATED IN ELECTRICAL ROOM. MOUNT FIXTURE AT 20' 0" AFF.
4. POWER-PACK WILL BE CONNECTED AHEAD OF LIGHT FIXTURE TYPE "L".
5. POWER-PACK FOR EXHAUST FAN CONTROL. EXHAUST FAN TO TURN ON
WHEN ROOMS 120, 121, 122 ARE OCCUPIED.
6. LIGHT FIXTURE SHALL BE SERVED FROM AN EMERGENCY LIGHTING
INVERTER VIA RELAY PANEL ARP8 LOCATED IN MECHANICAL/ELECTRICAL
ROOM 111. INVERTER SHALL BE MEYERS 1-EM-1-S OR APPROVED
EQUAL. RE: E401.
7. LIGHT FIXTURE TYPE "XB" SHALL BE SERVED VIA RELAY PANEL "RP8"
LOCATED IN ELECTRICAL ROOM. MOUNT FIXTURE AT 9' 6" AFF.
BRIDGE A1 AND A2
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
| General Sheets |
| G-102 |
| Plumbing Sheets |
| ED-102 |
| E-101 |
| E-102 |
| E-111 |
| E-112 |
| E-113 |
| E-201 |
| E-202 |
| E-401 |
| E-501 |
| E-601 |
| E-602 |
| E-603 |
| E-604 |
| E-605 |
| E-606 |
| E-607 |
| E-608 |
| Telecomm Sheets |
| TN-000 |
| TN-001 |
| TND-101 |
| TND-102 |
| TN-011 |
| TN-101 |
| TN-102 |
| TN-201 |
| TN-202 |
| TN-401 |
| TN-402 |
| TN-501 |
| TN-601 |
| TN-602 |
| TN-603 |
| Fire Protection Sheets |
| LS101 |
| LS102 |
| FD101 |
| FP-001 |
| FP-101 |
| FP-102 |
| FP-103 |
| FP-501 |
| FP-502 |
| FP-801 |
| FP-802 |
| FA-001 |
| FA-101 |
| FA-102 |
| FA-501 |
| FA-601 |
File details come from the government source that posted it.