B615_Final_Design_Plans_Aug_12_2019_Sheet_-162__of_191.pdf

PDF 455 KB Posted

Attached to
JBSA FSH ARNORTH Bldg 615 Renovation Project for Army Band
Solicitation number
W9126G-19-B-3286
Issued by

About this file

B615 Final Design Plans Sheet 162 of 191

View the file

Other files

File Type Posted
C1_Rev_2_SF_1409_Abstract_of_Offers-Page2of3_PRINT1.pdf PDF
C1_Rev_SF_1409_Abstract_of_Offers-Page_3of3.pdf PDF
C1_Rev_2_SF_1409_Abstract_of_Offers-Page1of3_Signed_29Sep_19.pdf PDF
am_0007.pdf PDF
am_0006.pdf PDF
am_0005_12_Sep_19.pdf PDF
Revise_Site_Visit_Form_11_Sep_19.pdf PDF
B3_Amendment_03_30_Aug_19.pdf PDF
Amendment_02_Change_of_Solicitation_closing_date_and_Bidder_Key_28_Aug_19.pdf PDF
B3_Unescorted_Access_Request_Form_pg_1-4-26_Aug_19-5.pdf PDF
JBSA_FSH_ARNORTH_Building_615-Amend_01.pdf PDF
B615_Final_Design_Plans_Aug_12_2019_Sheet_-165__of_191.pdf PDF
B615_Final_Design_Plans_Aug_12_2019_Sheet_-136_-144__of_191.pdf PDF
B3_B615_Final_Design_Plans_Aug_12_2019_Sheet_1-7_of_191.pdf PDF
W9126G19B3286_DIV_02_Specifications_Appendix_A_Abatement_Guidelines_Part_2_of_2.pdf PDF
B3_W9126G19B3286_DIV_27_28_31_and_32_Specifications_23_Aug_19.pdf PDF
B3_B615_Final_Design_Plans_Aug_12_2019_Sheet_20-22_of_191.pdf PDF
B615_Final_Design_Plans_Aug_12_2019_Sheet_-166_-170__of_191.pdf PDF
B3_W9126G19B3286_DIV_08_to_DIV_10_Specifications_23_Aug_19.pdf PDF
W9126G19B3286_Attachment_A_HAZMAT_SURVEY_Section_1A_of_5_Sampling_Methodology.pdf PDF
W9126G19B3286_Attachment_A_HAZMAT_SURVEY_Section_1C.2_of_5_All_Other_areas__Lead_Based_Paint_Findings.pdf PDF
B615_Final_Design_Plans_Aug_12_2019_Sheet_-113_-_115__of_191.pdf PDF
B3_W9126G19B3286_DIV_03_to_DIV_06_Specifications_23_Aug_19.pdf PDF
B615_Final_Design_Plans_Aug_12_2019_Sheet_-127_-130__of_191.pdf PDF
B615_Final_Design_Plans_Aug_12_2019_Sheet_-123_-126__of_191.pdf PDF
W9126G19B3286_Attachment_A_HAZMAT_SURVEY_Section_3_of_5.pdf PDF
B615_Final_Design_Plans_Aug_12_2019_Sheet_-160_-161__of_191.pdf PDF
B3_B615_Final_Design_Plans_Aug_12_2019_Sheet_-61-67_of_191.pdf PDF
B3_B615_Final_Design_Plans_Aug_12_2019_Sheet_-46-50_of_191.pdf PDF
W9126G19B3286_Attachment_A_HAZMAT_SURVEY_Section_4_of_5_page_13_to_21_of_21.pdf PDF
B3_B615_Final_Design_Plans_Aug_12_2019_Sheet_-51-55_of_191.pdf PDF
B3_B615_Final_Design_Plans_Aug_12_2019_Sheet_23-27_of_191.pdf PDF
B615_Final_Design_Plans_Aug_12_2019_Sheet_-186__of_191.pdf PDF
B615_Final_Design_Plans_Aug_12_2019_Sheet_-179_-183__of_191.pdf PDF
B3_B615_Final_Design_Plans_Aug_12_2019_Sheet_-75-77_of_191.pdf PDF
B3_W9126G19B3286_DIV_02_Specifications_Appendix_A_Abatement_Guidelines_ACM_Map.pdf PDF
B3_B615_Final_Design_Plans_Aug_12_2019_Sheet_28-30_of_191.pdf PDF
B3_W9126G19B3286_DIV_26_Specifications_23_Aug_19.pdf PDF
W9126G19B3286_Attachment_A_HAZMAT_SURVEY_Section_1C.3_of_5_Lead_Based_Paint_Findings.pdf PDF
W9126G19B3286_Attachment_A_HAZMAT_SURVEY_Section_4_of_5_page_17_to_21_of_21.pdf PDF
W9126G19B3286_Attachment_A_HAZMAT_SURVEY_Section_1E_of_5_Conclusions_and_recommendations.pdf PDF
B3_B615_Final_Design_Plans_Aug_12_2019_Sheet_-78-81_of_191.pdf PDF
B615_Final_Design_Plans_Aug_12_2019_Sheet_-187__of_191.pdf PDF
B3_B615_Final_Design_Plans_Aug_12_2019_Sheet_36_-40_of_191.pdf PDF
W9126G19B3286_Attachment_A_HAZMAT_SURVEY_Section_4_of_5_page_10-_11_of_21.pdf PDF
B3_B615_Final_Design_Plans_Aug_12_2019_Sheet_31-35_of_191.pdf PDF
B3_W9126G19B3286_DIV_01_Specifications_23_Aug_19.pdf PDF
B615_Final_Design_Plans_Aug_12_2019_Sheet_-184__of_191.pdf PDF
B3_W9126G19B3286_DIV_02_Specifications_Asbestos_Abatement_23_Aug_19.pdf PDF
B3_B615_Final_Design_Plans_Aug_12_2019_Sheet_16-19_of_191.pdf PDF
Show 40 more

Latest 50 of 92 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DN

J

J

PP

PP

PP

J

J

J

J

J

J

EE

EF

E7.2 E7.8

E

D

C

W1 W2 W3 W4 W5 W6 W7 W8 W9 W10 W11 W12 W13 W14 W15 W16 W17 W18

WA

WB

WC

WD

EA

EB

EC

ED

E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12

MECHANICAL

RECEPT.

WOMEN LOCKER

WOMEN

OPEN OFFICE

ELECTRICAL

JAN

SHOWERS

STORAGE

CORR.

C101

CORR.

C102

CORR.

C104

ELEV.

E1

MACHINE

GROUP

REHEARSAL 4

GROUP

REHEARSAL 3

GROUP

REHEARSAL 2

MECHANICAL /

ELECTRICAL

GROUP

REHEARSAL 1

SUPPLY OFFICE

STORAGE

STORAGE

COMM.

SPRINKLER

STG

INSTRUMENT

MAINTENANCE

MEN LOCKER

MEN SHOWER

MENS

IND. PRACTICE

ROOMS

MECH / ELECT

INSTRUMENT

STORAGE

CORR.

C105

CORR.

C109

CORR.

C110

CORR.

C106 CORR.

C107

CORR.

C108

E-401

E-401

E-401

GFI

GFI

GFI

WP,GFI

WP,GFI WP,GFI

WP,GFI

WP,GFI

WP,GFIWP,GFI

WP,GFI

WP,GFI

WP,GFI

WP,GFI

WP,GFI

WP,GFI

GFI

GFI

GFI

GFI

GFI

GFI

E-401

M1-1

B1-2

B1-3

B3-4

B3-5

B3-5

B3-6

B3-9

B3-8

B3-7

B3-10

B3-11

B3-12

B3-13 B3-14

B1-9

B1-10

B1-8

B1-7

B1-5

B1-12

GFI

B3-16

B3-15

B3-24 B3-25

B3-26

B3-17

B3-23

B3-21 B3-20,22 2 #12, #12G., 3/4"C.

GWH

GWH

M1-24

B3-18

"FACP"

B3-37

B1-4

B1-6

B1-11

B1-18B1-19

B3-36

GFI

B3-35

M1-23

M2-29

B3-19

M2-22

LEGEND

PP nLIGHT nPP20 PL PLUG LOAD CONTROL

POWER PACK

R E

E

NI

GNELANOI

SS

E F

O R

S

TATE O

SAXETF

P

VISHAL R. BHAN

104552

NECI

L

SED

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

AUGUST 12, 2019

E-101

P O

W E

R F

L O

O R

P L A

N

F

IR

S T

F L O

O R

R E

N O

V A

T

IO

N O

F B

U

IL

D

IN

G

V A

J

V A

J

V B

H A

N

A U

G U

S T

FINAL SUBMITTAL

K F

B

L D

G E

L E

C T

R

IC

A L

W G

B

1/8" = 1'-0"

1 POWER FLOOR PLAN - FIRST FLOOR

NORTH

0' 8' 16'

GRAPHIC SCALE 1/8" = 1'-0"

4'

GENERAL NOTES

1. REFER TO EG-001 FOR LEGEND, ABBREVIATIONS, AND EG-002 FOR

GENERAL NOTES.

2. THE INSTALLATION OF CONDUIT IN CONCRETE FLOOR TOPPINGS LESS

THAN 76MM THICK IS PROHIBITED.

3. DO NOT INSTALL BACK-TO-BACK OR THRU-WALL BOXES IN WALLS

WHERE SOUND TRANSMISSION IS OBJECTIONABLE.

NOTES BY SYMBOL " "

1. BMS EQUIPMENT POWER. FIELD VERIFY EXACT LOCATION AND

MOUNTING HEIGHT WITH TELECOM DRAWINGS PRIOR TO ROUGH-IN.

2. PROVIDE JUNCTION BOX AND MAKE FINAL CONNECTION TO HAND

DRYER. FIELD VERIFY EXACT LOCATION AND MOUNTING HEIGHT WITH

ARCHITECTURAL DRAWINGS PRIOR TO ROUGH-IN.

3. PROVIDE POWER TO FIRE ALARM CONTROL PANEL (FACP).

4. PROVIDE JUNCTION BOX AND MAKE FINAL CONNECTION TO GAS FIRED

TANK TYPE WATER HEATER. FIELD VERIFY EXACT LOCATION AND

MOUNTING HEIGHT WITH PLUMBING DRAWINGS PRIOR TO ROUGH-IN.

5. JUNCTION BOX FOR HEAT TRACE. REFER TO PLUMBING SHEET PP-103

FOR MORE INFORMATION.

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

General Sheets
G-102
Plumbing Sheets
ED-102
E-101
E-102
E-111
E-112
E-113
E-201
E-202
E-401
E-501
E-601
E-602
E-603
E-604
E-605
E-606
E-607
E-608
Telecomm Sheets
TN-000
TN-001
TND-101
TND-102
TN-011
TN-101
TN-102
TN-201
TN-202
TN-401
TN-402
TN-501
TN-601
TN-602
TN-603
Fire Protection Sheets
LS101
LS102
FD101
FP-001
FP-101
FP-102
FP-103
FP-501
FP-502
FP-801
FP-802
FA-001
FA-101
FA-102
FA-501
FA-601

File details come from the government source that posted it.