B615_Final_Design_Plans_Aug_12_2019_Sheet_-162__of_191.pdf
PDF 455 KB Posted
- Solicitation number
- W9126G-19-B-3286
About this file
B615 Final Design Plans Sheet 162 of 191
View the file
Other files
Show 40 more
Latest 50 of 92 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
J
J
PP
PP
PP
J
J
J
J
J
J
EE
EF
E7.2 E7.8
E
D
C
W1 W2 W3 W4 W5 W6 W7 W8 W9 W10 W11 W12 W13 W14 W15 W16 W17 W18
WA
WB
WC
WD
EA
EB
EC
ED
E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12
MECHANICAL
RECEPT.
WOMEN LOCKER
WOMEN
OPEN OFFICE
ELECTRICAL
JAN
SHOWERS
STORAGE
CORR.
C101
CORR.
C102
CORR.
C104
ELEV.
E1
MACHINE
GROUP
REHEARSAL 4
GROUP
REHEARSAL 3
GROUP
REHEARSAL 2
MECHANICAL /
ELECTRICAL
GROUP
REHEARSAL 1
SUPPLY OFFICE
STORAGE
STORAGE
COMM.
SPRINKLER
STG
INSTRUMENT
MAINTENANCE
MEN LOCKER
MEN SHOWER
MENS
IND. PRACTICE
ROOMS
MECH / ELECT
INSTRUMENT
STORAGE
CORR.
C105
CORR.
C109
CORR.
C110
CORR.
C106 CORR.
C107
CORR.
C108
E-401
E-401
E-401
GFI
GFI
GFI
WP,GFI
WP,GFI WP,GFI
WP,GFI
WP,GFI
WP,GFIWP,GFI
WP,GFI
WP,GFI
WP,GFI
WP,GFI
WP,GFI
WP,GFI
GFI
GFI
GFI
GFI
GFI
GFI
E-401
M1-1
B1-2
B1-3
B3-4
B3-5
B3-5
B3-6
B3-9
B3-8
B3-7
B3-10
B3-11
B3-12
B3-13 B3-14
B1-9
B1-10
B1-8
B1-7
B1-5
B1-12
GFI
B3-16
B3-15
B3-24 B3-25
B3-26
B3-17
B3-23
B3-21 B3-20,22 2 #12, #12G., 3/4"C.
GWH
GWH
M1-24
B3-18
"FACP"
B3-37
B1-4
B1-6
B1-11
B1-18B1-19
B3-36
GFI
B3-35
M1-23
M2-29
B3-19
M2-22
LEGEND
PP nLIGHT nPP20 PL PLUG LOAD CONTROL
POWER PACK
R E
E
NI
GNELANOI
SS
E F
O R
S
TATE O
SAXETF
P
VISHAL R. BHAN
104552
NECI
L
SED
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
AUGUST 12, 2019
E-101
P O
W E
R F
L O
O R
P L A
N
F
IR
S T
F L O
O R
R E
N O
V A
T
IO
N O
F B
U
IL
D
IN
G
V A
J
V A
J
V B
H A
N
A U
G U
S T
FINAL SUBMITTAL
K F
B
L D
G E
L E
C T
R
IC
A L
W G
B
1/8" = 1'-0"
1 POWER FLOOR PLAN - FIRST FLOOR
NORTH
0' 8' 16'
GRAPHIC SCALE 1/8" = 1'-0"
4'
GENERAL NOTES
1. REFER TO EG-001 FOR LEGEND, ABBREVIATIONS, AND EG-002 FOR
GENERAL NOTES.
2. THE INSTALLATION OF CONDUIT IN CONCRETE FLOOR TOPPINGS LESS
THAN 76MM THICK IS PROHIBITED.
3. DO NOT INSTALL BACK-TO-BACK OR THRU-WALL BOXES IN WALLS
WHERE SOUND TRANSMISSION IS OBJECTIONABLE.
NOTES BY SYMBOL " "
1. BMS EQUIPMENT POWER. FIELD VERIFY EXACT LOCATION AND
MOUNTING HEIGHT WITH TELECOM DRAWINGS PRIOR TO ROUGH-IN.
2. PROVIDE JUNCTION BOX AND MAKE FINAL CONNECTION TO HAND
DRYER. FIELD VERIFY EXACT LOCATION AND MOUNTING HEIGHT WITH
ARCHITECTURAL DRAWINGS PRIOR TO ROUGH-IN.
3. PROVIDE POWER TO FIRE ALARM CONTROL PANEL (FACP).
4. PROVIDE JUNCTION BOX AND MAKE FINAL CONNECTION TO GAS FIRED
TANK TYPE WATER HEATER. FIELD VERIFY EXACT LOCATION AND
MOUNTING HEIGHT WITH PLUMBING DRAWINGS PRIOR TO ROUGH-IN.
5. JUNCTION BOX FOR HEAT TRACE. REFER TO PLUMBING SHEET PP-103
FOR MORE INFORMATION.
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
| General Sheets |
| G-102 |
| Plumbing Sheets |
| ED-102 |
| E-101 |
| E-102 |
| E-111 |
| E-112 |
| E-113 |
| E-201 |
| E-202 |
| E-401 |
| E-501 |
| E-601 |
| E-602 |
| E-603 |
| E-604 |
| E-605 |
| E-606 |
| E-607 |
| E-608 |
| Telecomm Sheets |
| TN-000 |
| TN-001 |
| TND-101 |
| TND-102 |
| TN-011 |
| TN-101 |
| TN-102 |
| TN-201 |
| TN-202 |
| TN-401 |
| TN-402 |
| TN-501 |
| TN-601 |
| TN-602 |
| TN-603 |
| Fire Protection Sheets |
| LS101 |
| LS102 |
| FD101 |
| FP-001 |
| FP-101 |
| FP-102 |
| FP-103 |
| FP-501 |
| FP-502 |
| FP-801 |
| FP-802 |
| FA-001 |
| FA-101 |
| FA-102 |
| FA-501 |
| FA-601 |
File details come from the government source that posted it.