ELEVATOR PIT WALL
PEA GRAVEL COMPACTED TO
95% REL COMPACTION
PLACE UP TO 1 FT ABOVE TOP
OF PIPE
GEOTEXTTILE FABRIC
SPECS OUTLINED IN EARTHWORK SECTION
OF SPECS
WATERPROOFING,
REFER ARCH
6 IN PERFORATED PVC SCH 80 PIPE WITH
PERFORATIONS ON BOTTOM. PROVIDE FILTER
FABRIC AROUND PIPE PRIOR TO EMBEDMENT.
REFER SHEETS C-50X FOR INVERT ELEVATIONS
N
O M
1 1/2"
DUCTILE IRON GRATE
ADA COMPLIANT
AASHTO M306 - H20 & HS25
VARIES, SEE PLANS
6 IN
12 IN APPROX
20 IN APPROX
I N
SIDEWALK BEYOND
IN EJ
ADA COMPLIANT GALVANIZED
DUCTILE IRON GRATE, REFER DETAIL B3 THIS SHT
HOT DIPPED GALVANIZED
DUCTILE IRON GRATE FRAME
FRAME ANCHOR
2 IN SAND COMPACTED TO 95 PCT
RELATIVE COMPACTION, ASTM D1557
SLOPE @ 0.5%
CONCRETE
fc' = 3000 PSI
US Army Corps of Engineers ®
SHEET ID
U S
A
R M
Y
C
O R
P
O
F
E
N G
I N
E E
R S
D R
A W
N
B
Y
R
R
D E
S I G
N E
D
B
Y
R
R
S U
B M
I T
T E
D
B
Y
K
F
N I
S I Z
E
C H
E C
K E
D
B
Y
D
D
A N
S I
D
F I L E
M
E
I S
S U
E
D
A T
E
A U
G U
T
C O
N T
R A
C
S O
L I C
I T
A T
I O
N
N
O
F I
M
B E
R
1 2 3 4 5
D
C
B
A
J O
I N
T
B
A S
E
S
T
O N
O R
T
S
M
H
U
S T
O N
T
E X
A S
R E
N O
V A
B
D
G
W G
B
K E
N A
L L
F
R E
E S
E
A
D
C
H O
L S
H O
U S
T O
N
T
E X
A S
FINAL SUBMITTAL
F O
W
R
S
T R
I C
T
D R
A I N
A G
E
D
E T
A I L S
C-507
NOT TO SCALE
C1
C-507
FRENCH DRAIN NEXT TO ELEVATOR PIT
C3
C-507
TRENCH DRAIN DETAIL
B3
C-507
ADA COMPLIANT GRATE DETAIL
AUG 12, 2019
F
T
T
Y P
9 FT WIDE (TYP)
Y
P
A
PAINT 4 IN
WHITE STRIP
PAINT 4 IN
BLUE BORDER
STRIPE (TYP)
NO
PARKING
PAINT ISA
(TYP)
INSTALL ACCESSIBLE
PARKING SIGN AT EACH STALL
45 DEG
NO
PARKING
45 DEG
8 FT MIN (TYP)
F
T
T
Y P
6 IN CURB
6 IN CURB
0 IN CURB
2% MAX
2% MAX
10% MAX AT CURB
10% MAX AT CURB
X
X
LEVEL LANDING, MIN 5 FEET WIDE
AND 5 FEET LONG
5 FT WIDTH OF CURB RAMP (TYP)
MIN 3 FT
2% MAX
X
2% MAX
X
LEVEL LANDING, MIN 5 FEET WIDE
AND 5 FEET LONG
0 IN CURB
10% MAX AT CURB
10% MAX AT CURB
5 FT WIDTH OF CURB RAMP (TYP)
MIN 3 FT
1.6 IN MIN TO 2.4 MIN
CENTER TO CENTER SPACING
N
B A
B
A S
E
S
P A
C I N
G
TOP DIA
50 TO 65% OF BASE DIA
0.2 IN
BASE DIA
0.90 IN MIN TO 1.4 IN MAX
BASE DIA
0.90 IN MIN TO 1.4 IN MAX
US Army Corps of Engineers ®
SHEET ID
M
Y
C
O R
E
N G
I N
E E
R S
D R
A W
N
B
Y
R
R
D E
S I G
N E
D
B
Y
R
R
S U
B M
I T
T E
D
B
Y
K
F
N I
S I Z
E
C H
E C
K E
D
B
Y
D
D
A N
S I
D
F I
M
E
I S
S U
E
D
A T
E
A U
G U
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
F I
M
B E
R
1 2 3 4 5
D
C
B
A
J O
I N
T
B
A S
E
S
T
O N
O R
T
S
U
S T
O N
T
E X
A S
R E
N O
V A
D
G
W G
B
K E
N A
L L
F
R E
E S
E
A
C
H O
L S
H O
U S
T O
N
T
E X
A S
FINAL SUBMITTAL
F O
R
S
T R
I C
T
A D
A
D
E T
A I L S
O
F
C-508
NOTES:
1. DETECTABLE WARNING SURFACE SHALL BE EITHER:
(A) RECESSED AND CAST IN CONCRETE IF APPLYING TO NEW CONCRETE, OR
(B) GLUED TO EXISTING CONCRETE AND CAULKING APPLIED AROUND PERIMETER EDGES.
2. DETECTABLE WARNING SURFACE SHALL BE INSTALLED AT BOTTOM OF RAMP. SEE THE LAYOUT
PLANS FOR SPECIFIC LOCATIONS TO INSTALL THE WARNING SURFACES.
3. DETECTABLE WARNING DEVICES TO BE YELLOW COLOR CONFORMING TO FEDERAL COLOR NO.
33538.
4' - 5"
3' - 0 "
PAINT BLUE
PAINT 4 IN
WHITE BORDER
PARKING
ONLY
VAN ACCESSIBLE
MINIMUM
FINE $250
G
H
G
H
12 IN DIAMETER HOLE
PORTLAND CEMENT CONCRETE
fc' = 3000 psi
ATTACH SIGN TO POST WITH BOLTS AT TOP,
CENTER, AND BOTTOM. USE THEFT PROOF
BRACKETS, BOLTS, BUTS, WASHERS.
REFLECTORIZED SIGN CONSTRUCTED OF PORCELAIN STEEL
WITH BEADED TEXT OR EQUAL AREA OF SIGN TO BE A MIN OF 70
SQ IN IN WHITE ON DARK BLUE BACKGROUND
VAN ACCESSIBLE SIGN
MINIMUM FINE $250 SIGN
2 IN STANDARD GALVANIZED STEEL POST
NOT TO SCALE
FINISH GRADE
C1
C-508
PARKING STALLS WITH HANDICAP
ACCESSIBLE
B4
C-508
B4
C-508
ISA ACCESSIBLITY SIGN
CURB RAMPS (TYP)
A1
C-508
TRUNCATED DOME
C4
C-508
C4
C-508
TRUNCATED DOME (TYP)
A4
C-508
A4
C-508
HANDICAPPED SIGN AND POST
NOTES:
1) ACCESS AILE SHALL HAVE A MIN WIDTH OF 8 FT PER ABA CHAPTER 5: 502.2 ACCESS AILE. THE
LENGTH SHALL BE THE PARKING LANE LENGTH.
2) TRUNCATED DOME SHALL COMPLY WITH ABA TRUNCATED DOME REQUIREMENTS, CHAPTER 7:
705 DETECTABLE WARNINGS.
3) WIDTH OF CURB LANDING BEHIND CURB RAMP SHALL BE 5 FEET U.O.N IN PLANS. IT SHALL BE NO
LESS THAN 36 IN WIDTH PER ABA CHAPTER 4, 406: CURB RAMPS.
A2
C-508
INSTALL BREAKAWAY CONNECTION AT THE BOTTOM
NOT USED
AUG 12, 2019
6'
1'
1'
3 IN CLR
US Army Corps of Engineers ®
SHEET ID
M
Y
C
O R
E
N G
I N
E E
R S
D R
A W
N
B
Y
R
R
D E
S I G
N E
D
B
Y
R
R
S U
B M
I T
T E
D
B
Y
K
F
N I
S I Z
E
C H
E C
K E
D
B
Y
D
D
A N
S I
D
F I
M
E
I S
S U
E
D
A T
E
A U
G U
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
F I
M
B E
R
1 2 3 4 5
D
C
B
A
J O
I N
T
B
A S
E
S
T
O N
O R
T
S
U
S T
O N
T
E X
A S
R E
N O
V A
D
G
W G
B
K E
N A
L L
F
R E
E S
E
A
C
H O
L S
H O
U S
T O
N
T
E X
A S
FINAL SUBMITTAL
F O
R
S
T R
I C
T
A D
A
P
A T
H W
Y
T
A I L S
S H
E E
T
O
F
C-509
NOT TO SCALE
M A
T C
H R
A M
P S
L O
P E
TYPICAL POST FOOTING
BOTTOM OF WHEEL GUIDE, <4 INCH FROM
BOTTOM SURFACE
1-1/4 IN MIN AND 2-IN MAX GALVANIZED
STEEL POST
12 IN MIN
2 IN GALVANIZED STEEL POST
PORT;LAND CEMENT CONCRETE
fc' = 3000 psi
I N
6 IN TxDOT GRADES 1, 2 OR 3COMPACTED TO
95% COMPACTION
POST INSTALL SLEEVE
CAST IN CONCRETE FOR SLEEVE
INSTALLATION FOLLOWING CON PLACEMENT
NOTES:
1. RAMP SLOPE SHALL BE LESS THAN 1:12
2. PROVIDE LANDINGS 6 FOOT IN DIRECTION OF TRAVEL AND
5 FOOT WIDE FOR EVERY 30 INCH RISE.
3. HANDRAIL EXTENSIONS SHALL BE 1-1/4 IN AND 2 IN MAX DIAMETER GALVANIZED
STEEL, WELD ALL JOINTS.
4. HANDRAIL EXTENSIONS TO EXTEND 12 IN HORIZONTAL PAST THE TOP OR BOTTOM OF
RAMP AND SHALL BE PARALLEL TO THE SURFACE OF THE LEVEL LANDING.
5. WHEEL GUIDE SHALL BE
IN THICK BY 4 IN WIDE WELDABLE FLAT STEEL FOR LENGTH OF
WHEEL GUIDE RAIL AND SHALL BE NO MORE THAN 4 IN ABOVE THE TOP OF RAMP.
6. ALL STEEL, UNLESS SPECIFICALLY NOTED OTHERWISE, SHALL BE HOT-DIPPED GALVANIZED.
REPAIR ALL FIELD WELDS AND OTHER DAMAGED AREAS PER ASTM A780.
5 FOOT MIN
PAINT 4-IN WHITE
STRIPE (TYP)
45 DEG
Y
P
LANDING
RAMP
A1
C-509
A1
C-509
POST FOOTING FOR HANDRAILS
B1
C-509
HANDRAIL DETAIL FOR RAMP (TYP)
B3
C-509
CROSSWALK STRIPING (TYP)
AUG 12, 2019
A3
C-509
HANDRAIL DETAIL FOR STOOP/STAIR
A1
C-509
TYPICAL POST FOOTING
1-1/4 IN MIN AND 2-IN MAX GALVANIZED
STEEL POST
NEW STOOP/STAIR
REFER TO DET A-1, C-507
FOR CONSTRUCTION DETAILS
CAST STONE CAP
WOOD FENCE TO MATCH EXIST.
LIMESTONE VENEER TO MATCH
EXIST. MECH. YARD COLUMN
1'-0" W x 1'-0" D PERIMETER BEAM -
CONT. 3 SIDES
GALV. STEEL POSTS (TYP.)
3"
CLR
VARIES
0' 10"
1' 2"
C
L R
C
N
C
L R
#4 REBAR, 12 IN
O.C. E.W.
fc' = 3,000 PSI #4 REBAR, CONT
6 IN EX SUBGRADE, COMPACTED TO 95%
REL COMPACTION BY ASTM D-1557
#4 REBAR,
CONT
TOP OF SLAB TO BE 4 INCHES ABOVE GRADE OF SURROUNDING EARTH
0'10"
1' 2"
LIMESTONE VENEER W/ TIES TO
STEEL POST. MATCH EXISTING
EQUIP. YARD COLUMNS
CUT STONE CAP ANCHOR TO BE
EMBEDDED INTO GROUTED
CORE, ABOVE
STEEL POST
1" 1'-4" 1"
NO PARKING
FIRE LANE
NO PARKING
FIRE LANE
M
I N
6 IN RED STRIPING TYP.
4 IN WHITE LETTERING TYP.
10 FT SPACING TYP
3"
CLR
VARIES
C
L R
C
N
#4 REBAR, 12 IN
O.C. E.W.
fc' = 3,000 PSI
6 IN EX SUBGRADE, COMPACTED TO 95%
REL COMPACTION BY ASTM D-1557
TOP OF SLAB TO BE 4 INCHES ABOVE GRADE OF SURROUNDING EARTH
US Army Corps of Engineers ®
SHEET ID
M
Y
C
O R
E
N G
I N
E E
R S
D R
A W
N
B
Y
R
R
D E
S I G
N E
D
B
Y
R
R
S U
B M
I T
T E
D
B
Y
K
F
N I
S I Z
E
C H
E C
K E
D
B
Y
D
D
A N
S I
D
F I
M
E
I S
S U
E
D
A T
E
A U
G U
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
F I
M
B E
R
1 2 3 4 5
D
C
B
A
J O
I N
T
B
A S
E
S
T
O N
O R
T
S
U
S T
O N
T
E X
A S
R E
N O
V A
D
G
W G
B
K E
N A
L L
F
R E
E S
E
A
C
H O
L S
H O
U S
T O
N
T
E X
A S
FINAL SUBMITTAL
F O
R
S
T R
I C
T
M I S
C E
L L A
N E
O U
S
D
E T
A I L S
C-510
NOT TO SCALE
NOTES:
1) EQUIPMENT PAD DIMENSIONS SHOWN ARE PER SHEET CS-105. CO-ORDINATE EQUIPMENT PAD DIMENSIONS TO ENSURE MIN 6 INCH CLEARANCE BEYOND THE
FOOTPRINT OF THE EQUIPMENT. VERIFY WITH MANUFACTURER FOR ACTUAL DIMENSIONS OF EQUIPMENT.
2) CO-ORDINATE LOCATION OF EQUIPMENT PAD WITH MECHANICAL PLANS.
3) CO-ORDINATE WITH THE EQUIPMENT MANUFACTURER TO SECURE THE EQUIPMENT TO THE PAD VIA ANCHOR BOLTS.
4) ANCHOR BOLT DIAMETER AND EMBEDMENT DEPTH TO BE BASED ON MANUFACTURER RECOMMENDATIONS.
5) TOP OF SLAB ELEVATION TO BE 4 IN ABOVE GRADE OF SURROUNDING EARTH.
C1
C-510
UTILITY YARD FENCE
C3
C-510
UTILITY YARD FENCE COLUMN
B1
C-510
EQUIPMENT PAD DETAIL
B3
C-510
FIRE LANE STRIPING DETAIL
AUG 12, 2019
NOTES:
1) EQUIPMENT PAD DIMENSIONS SHOWN ARE PER SHEET CS-105. CO-ORDINATE EQUIPMENT PAD DIMENSIONS TO ENSURE MIN 6 INCH CLEARANCE BEYOND THE
FOOTPRINT OF THE EQUIPMENT. VERIFY WITH MANUFACTURER FOR ACTUAL DIMENSIONS OF EQUIPMENT.
2) CO-ORDINATE LOCATION OF EQUIPMENT PAD WITH MECHANICAL PLANS.
3) CO-ORDINATE WITH THE EQUIPMENT MANUFACTURER TO SECURE THE EQUIPMENT TO THE PAD VIA ANCHOR BOLTS.
4) ANCHOR BOLT DIAMETER AND EMBEDMENT DEPTH TO BE BASED ON MANUFACTURER RECOMMENDATIONS.
5) TOP OF SLAB ELEVATION TO BE 4 IN ABOVE GRADE OF SURROUNDING EARTH.
A1
C-510
EQUIPMENT PAD DETAIL
US Army Corps of Engineers ®
SHEET ID
M
Y
C
O R
E
N G
I N
E E
R S
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
C H
E C
K E
D
B
Y
A N
S I
D
F I L
E
N
A M
E
I S
S U
E
D
A T
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
F I L
E
N
U M
B E
R
1 2 3 4 5
D
C
B
A
R E
N O
V A
T I O
N
O
F
B
U I L
D I N
G
J O
I N
T
B
A S
E
S
T
O N
I O
F O
U
S T
O N
T
X
K E
N A
I
V
Y
I V
E
S
U I T
E
H O
U S
T O
N
T
E X
P H
O N
E
S L
A
A
R C
H I T
E C
T S
S E
C
D
R W
D R
W
A U
G U
W
G
B
FINAL SUBMITTAL
S-001
G E
N E
R A
L
N
O T
E S
GENERAL NOTES
DESIGN CRITERIA
1. Design Loads, structural analysis and proportioning of structural members is based upon the
a. International Building Code 2015 Edition and
b. ASCE 7-10:
c. Steel Deck Institute (SDI),
d. Design Manual for Composite Decks, Forms
Decks, Roof Decks, and Cellular Metal Floor
Deck with Electrical Distribution:
e. American Iron and Steel Institute (AISI), Cold-Formed Steel Design Manual: American
Institute of Steel Construction, Inc. (AISC), AISC
Steel Construction Manual, Thirteenth Edition;
(ASD); and
f. American Concrete Institute (ACI) Building Code
Requirements for Reinforced Concrete, ACI
318-14:
g. And Building Code Requirements for Masonry
Structures (ACI 530-11/ASCE 5-11/TMS 402-11.
2. Foundation Design based on Geotechnical
Engineering Report prepared by TTL, Inc., San
Antonio, Texas, Project No. 000190900845.01d June
12, 2019.
3. Design Live Loads:
Roof 20 PSF
Elevated Floors 80 PSF
4. Design Snow Load 5
PSF
5. Design Wind Loads based on ASCE 7-10:
Wind Speed: 115 MPH
Wind Exposure: C
Risk Category III
REINFORCED CONCRETE MASONRY UNIT WALLS
1. Masonry walls must be temporarily braced against lateral loads and displacement until the floor deck/roof deck has been permanently attached to joists and deck angles.
2. Concrete masonry units (CMU) shall conform to
ASTM C90, Grade N. Type 1.
3. Required strength of the concrete masonry assemblage (f'm) shall be 1500 psi.
4. Mortar shall be Type "S".
5. Cement shall conform to ASTM C150 Type I, low alkali. Mortar Cement conforming to ASTM C
1329-96 may be used. However, Masonry
Cements are not allowed.
6. Provide grout in accordance with ASTM C-476 and submit design mix for approval.
7. All reinforcing bars shall be new billet steel and shall conform to ASTM A-615, Grade 60.
8. All walls requiring vertical reinforcement (noted on plans) shall be #5 @ 48" on center. Add TWO (2)
#5 at jambs of all openings, and wall ends, THREE (3) #5 at corners (one in each of three adjoining cells). Provide additional vertical reinforcement for special conditions as detailed.
All vertical reinforcement to be in grout filled cells.
Provide dowels from foundation, same size & spacing.
9. Lap splices of reinforcing steel shall be a minimum of 48 bar diameters unless otherwise noted.
10. Vertical cells to be filled shall have vertical alignment sufficient to maintain a clear, unobstructed continuous vertical cell measuring not less than 2 inches by 3 inches. Excessive mortar fins and any other obstruction shall be removed from the cells to be grouted. Metal lath may be placed over cells not containing reinforcement to prevent filling with grout.
11. All cells containing vertical reinforcement shall be filled solidly with grout with a minimum compressive strength of 3000 psi at 28 days.
Grout shall be a workable mix suitable for pumping without segregation and shall be thoroughly mixed. Grout shall be placed by pumping or an approved alternate method and shall be placed before initial set or hardening occurs.
12. All reinforcing shall be in place prior to placing grout. Vertical reinforcing bars shall be held in position at the top, bottom and at intervals not arther a art than 10'-0 .
13. Allow C.M.U. walls to set at least 24 hours after completion before grouting. Grout shall be consolidated by puddling or mechanical vibration during placing and resolidation after excess moisture has been absorbed but before workability is lost. The filling of any section of a wall shall be completed in one day without interruptions greater than one hour, and placed in layers of 4 feet maximum.
14. Where the grout pour exceeds 4 feet in height, cleanouts shall be provided by suitable openings in the face shells in the bottom course of each cell to be filled, or other approved locations. The cleanouts shall be sealed after inspection and before being filled.
15. When cell filling is stopped for one hour or longer, horizontal construction joint shall be formed by stopping the pour of grout approximately 1/2 inch above or below bed joint.
16. End walls and cross webs forming cells to be filled shall be full bedded in mortar to prevent leakage of grout unless wall is to be poured solid.
17. Typical horizontal reinforcement shall be two (2)
#5 continuous in 8 x8 or 8 x16 deep continuous concrete filled bond beam below each floor and roof level, unless noted otherwise. If U block
(lintel block) is used for a bond at top of wall, holes must be made thru the U block so vertical reinforcement can extend into the U block.
Provide standard Ladder-(Truss-) Mesh type reinforcing or reviewed equivalent every other course (16" on center) and as per manufacturer's recommendations. Provide additional bond beams and lintel beams as detailed, noted, or required for a complete job.
18. Walls designated as spanning horizontal require horizontal, Truss-Mesh type, double wire reinforcement with adjustable eye-wire. For bid purposes reference Hohmann & Barnard, Inc., Los-All Reinforcement system, Fort Worth, Texas, (817/625-9781)
19. Provide vertical control joints at a maximum spacing of 20' starting at 10' from corners. Do not continue the typical Ladder-(Truss-) Mesh type joint reinforcement through the joint.
20. Continue bond beam reinforcement through the joint.
21. Provide horizontal joint reinforcement every other course where horizontal bar reinforcement is not specified.
22. Care shall be taken in backfilling against retaining walls. Backfilling shall not be permitted until at least 7 days after grouting. Heavy equipment shall not approach closer to the wall than a distance equal to the wall height.
23. Wall lengths less than or equal to four (4) times its' thickness shall be reinforced with #5 vertical reinforcing in filled cells, provide 1/4 diameter ties in every course (8 on center) in lieu of Dur-O-Wal reinforcing. Place as detailed.
WOOD FRAMING NOTES - TYPICAL
1. All framing lumber shall be Treated #2 Southern
Pine or better and shall comply with DOC PS 20 or equivalent
2. Provide joist or beam hanger where joists, rafters, or beams frame together or to each other at the same elevation. All hangers to be as manufactured by "Simpson" or a reviewed equivalent.
STRUCTURAL STEEL
1. Comply with American Institute of Steel
Construction, Inc. (AISC) Code of Standard
Practice for Steel Buildings and Bridges.
2. Rolled steel plates, shapes, and bars shall be structural quality carbon steel complying with
ASTM A-36, except where other type steel is shown.
3. Hollow Structural Sections (HSS) products shall comply with ASTM A500, Grade B, 46 KSI.
4. Steel Pipe products shall be cold-formed structural quality carbon steel, complying with
ASTM A53, Type E or S, Grade B.
5. All structural steel shall be fabricated, erected and painted in accordance with the Specifications for the Design, Fabrication, and Erection of Structural
Steel for Buildings as amended to date and the
Code of Standard Practice, latest edition as adopted by the American Institute of Steel
Construction.
6. Welding shall be done in accordance with the standard code for arc and gas welding in building construction as published by the American
Welding Society, except that all welding shall be done by the Electric arc process. All welding shall be performed by certified welders and shall conform to the latest code of the AWS.
7. Detailed connections have been designed by
Structural Engineer. Any connection not detailed or scheduled, or altered for fabrication purposes, shall be sized and detailed by fabricator and shall be marked for engineer's verification.
8. Erector shall examine areas and conditions under which structural steel work is to be installed, and notify Contractor in writing of conditions detrimental to proper and timely completion of work. Do not proceed with work until unsatisfactory conditions have been corrected in a manner acceptable to the erector.
9. Provide temporary shoring and bracing members with connections of sufficient strength to bear imposed loads. Remove temporary members and connections when permanent members are in place and final connections made. Permanent members shall include but are not limited to columns, beams, joists, and metal deck. Provide temporary guy lines to achieve proper alignment of structure as erection proceeds.
LIGHT WEIGHT STRUCTURAL STEEL
FRAMING SYSTEMS
1. All studs and accessories shall be of the type and size as indicated on the drawings and equivalent to those manufactured by ClarkDietrich
(1-800-543-7140) or Mario/Ware
(1-800-504-8119).
2. All structural members shall be designed in accordance with American Iron and Steel Institute
(AISI) "Specification For the Design of
Cold-Formed Steel Structural Members", LATEST
EDITION.
3. All framing members and accessories shall be formed from corrosion-resistant steel with a minimum G-60 coating, complying with the requirements of ASTM A525.
4. Cold-Formed Metal Framing shall comply with design criteria and shall include structural analysis data signed and sealed by the qualified professional engineer responsible for their preparation.
5. Prior to fabrication of framing, the contractor shall submit fabrication and erection drawings to the architect to obtain approval.
6. Prefabricated panels shall be square, with components attached in a manner as to prevent racking and to minimize distortion while lifting.
7. All framing components shall be cut squarely for attachment to perpendicular members, or, as required, for an angular fit against abutting members.
8. Fastening of components shall be with self-drilling screws or welding. Screws shall be of sufficient size to insure the strength of the connection. Wire tying of components shall not be permitted. All welds shall be touched up with a zinc-rich paint.
9. Tracks shall be securely anchored to the concrete slab with Hilti X-DNI 32 P8 Powder Actuated
Fasteners at 24 inch on center and to steel members with Hilti 0.145 diameter powder-actuated fasteners.
10. Complete, uniform and level bearing support shall be provided for the bottom tracks.
11. Abutting lengths of tracks shall each be securely anchored to a common structural element, butt-welded or spliced.
12. Studs shall be plumbed, aligned and securely attached to flanges of both upper and lower tracks.
13. Framing of wall openings shall include headers and support studs.
14. Temporary bracing, where required, shall be provided until erection is completed.
15. Resistance to bending and rotation about the minor axis shall be provided by horizontal strap or cold-rolled channel bracing.
16. Splices in studs shall not be permitted.
1. Allied Studco.
2. AllSteel Products, Inc.
3. California Expanded Metal Products Company.
4 ClarkDietrich.
5. Consolidated Fabricators Corp,:Building
Products Division.
6. Craco Metals Manufacturing, LLC.
7. Custom Stud, Inc.
8. Dale/Incor.
9. Design Shapes in Steel.
11. Formetal Co. inc. (The)
12. Innovative Steel Systems.
13. Marino/Ware: A Division of Ware Industries.
14. Quail Run Building Materials.
15. SCAFCO Corporation.
16. Southeastern Stud & Components, Inc.
17. Steel Construction Systems.
18. Steeler, Inc.
19. Super Stud Building Products, Inc.
20. The Steel Network. Inc.
21. United Metal Products, Inc.
METAL DECK
1. Floor deck shall be 0.6C 22 gage, painted, as manufactured by Vulcraft.
2. End laps shall be a minimum of 2" and shall always occur over supports. Side laps shall require a minimum of one-half flute.
3. Deck units shall be 3 or more spans and shall be attached to the structural supports at the end lap joints by welds not less than 5/8 inch in diameter, spaced not more than 12 inches o.c. across the width. Attachment at interior supports shall be by welds not less than 5/8 inch in diameter spaced not more than 12 inches o.c. across the width. .
(An elongated weld with an equal perimeter shall be acceptable.) Welds metal shall penetrate all thicknesses of material and shall have good fusion to the supporting member.
4. All field welding of deck shall be in strict accordance with ANSI/AWS D1.3. Structural
Welding Code - Sheet Steel .
5. Care shall be exercised in the selection of electrodes and amperage to provide a positive weld and prevent high amperage blow holes.
6. Welding washers shall be provided and used as recommended by the deck manufacturer.
7. Side laps of adjacent units shall be fastened with
#10 TEK Self-Drilling Screws at not more than 36 inches on center.
8. The deck (ends and sides) shall be attached to the deck support angle with welds not less than
5/8 inch in diameter and spaced @ 12 inches o.c.
maximum at the building perimeter and around all large openings through the deck.
9. (Option) Deck units may be attached to the structural supports at the end laps and at perimeter deck angles with HILTI ENP2K-21-L15 powder actuated fasteners spaced not more than
12 inches o.c. or HILTI 12-24x1 1/4 HWH #4
STLG screws @ 12 inches o.c.
SHOP DRAWING and SUBMITTAL REVIEW
1. The Government will review and approve
Contractor's shop drawings and related submittals
(as indicated below) with respect to the ability of the detailed work, when complete, to a properly functioning integral element of the overall system designed by The Government . A minimum of one hard copy set of shop drawings must be submitted if an electronic set is to be submitted.
2. A submittal made from a reproduction of construction documents produced by Calvetti & Associates will not be acceptable and will be returned without review.
3. Before submitting a shop drawing or any related material to The Government shall: review each such submission for conformance with the means, methods, techniques, sequences, and operations of construction, and safety precautions and programs incidental thereto, all of which are the sole responsibility of the Contractor; review submittals for dimensions and materials, approve each such submission before submitting it; and so stamp each such submission before submitting it. The
Government shall assume that no shop drawing or related submittal comprises a variation unless
Contractor advises The Government otherwise via a written instrument, which is acknowledged by The
Government in writing. The shop drawing and related material (if any) called for are indicated below. In the event that The Government will require more than seven (7) working days to perform review, The
Government shall so notify the Contractor.
4. Items:
A. Concrete Design Mix.
B. Concrete Reinforcement Shop Drawings.
C. Structural Steel
D. Mortar Design Mix
E. Grout Design Mix
F. Masonry Reinforcement Shop Drawings
G. Metal Deck Shop Drawings
H. Welder's Certification.
I. Truss Shop Drawings.
N. Product Data:
1. Certified copies of structural steel mill reports.
2. High-strength bolts.
2. Structural steel primer paint.
4. Admixtures.
5. Vapor Retarder.
6. Pier Bolsters and Sleds.
7. Curing compounds.
8. Mortar materials.
9. Grout materials.
10. Masonry materials.
11. Masonry joint reinforcement.
12. Masonry anchors, ties, and accessories.
13. Plywood.
14. Hurricane Ties.
5. The Government shall return shop drawings and related materials with comments provided that each submission has been called for and is stamped by the Contractor. The Government shall return without comment material not called for or which has not been approved by the Contractor. The
Government shall not review partial submissions or those which submissions for correlated items have not been received.
PLYWOOD PANELS
1. All panels shall comply with the requirements for their type in DOC PS 1 or PS 2, in addition to all applicable identification verifying testing and inspection compliance.
2. Roof panels to be APA Rated Sheathing, Exterior, 5/8" thick plywood or OSB.
3. Floor panels to be C-C, plugged, exterior APA
Rated, 3/4" thick tongue and groove. (Floor panels to be APA Rated Sturd-I-Floor, 3/4 thick, tongue and groove.)
4. Place panels with end joints staggered. All panels to be placed perpendicular to framing members.
5. Secure roof panels over firm bearing with 8d common nails at 6" o.c. at panel edges, at 12" o.c. at intermediate supports.
6. Leave 1/8" space at all panel edge joints and end joints of roof deck unless otherwise recommended by manufacturer.
7. Secure floor panels (Glue-Nailed) over firm bearing with 6d ring- or screw-shank nails @ 6 o.c. at panel edges, @ 12 o.c. at intermediate supports.
8. Use only adhesives conforming to APA
Specification AFG-1, applied in accordance with manufacturer's recommendations.
9. Butt floor panels end and edges to a close but not tight fit (allow 1/32 ). Block side edges of panels such that all ends and edges of panel are supported.
RIGID BEAM, CAST-IN-PLACE CONCRETE
FOUNDATON
1. Verify all dimensions. Coordinate with specifications and architectural plans prior to construction and notify Architect and/or Engineer of any discrepancies.
2. Concrete work shall be in accordance with the
American Concrete Institute Specifications, ACI
318 and ACI 301, Latest Edition.
3. Detailing, fabrication and erection of reinforcing bars, and all accessories unless otherwise noted, shall be in accordance with the ACI Manual of
Standard Practice for Detailing Reinforced
Concrete , ACI 315 latest edition.
4. Concrete shall develop 4000 psi in compression in
28 days but not less than 4-1/2 sacks of cement shall be used per cubic yard of concrete regardless of strength obtained. Slump shall not exceed five (5) inches.
5. Concrete shall contain a water-reducing admixture as per the manufacturer's specifications, in accordance with ASTM C494.
No calcium chloride will be permitted in concrete.
6. No horizontal construction joints will be permitted in slabs or beams.
7. Vertical construction joints in slabs are to be as shown on plans, or if not shown, as approved by engineer.
8. Reinforcing bars shall be new domestic billet steel and shall conform to ASTM A-615, grade 60 specifications.
9. Provide corner bars top and bottom at all beam corners and dead end beam intersections. Bars to be of equal size and quantity as the noted beam steel. Bars shall lap beam reinforcement
48 bar diameters.
10. Bars detailed as continuous shall be lapped 48 bar diameters at splices.
11. Extend the slab reinforcing steel, perpendicular to beam, to the top outside reinforcing bar of perimeter beams. Start the slab reinforcing steel, parallel to beam, not more than 6 from the top inside reinforcing bar of perimeter beams.
12. All conduit and plumbing lines in slab shall be placed below slab reinforcing. Do not bundle conduits or plumbing lines; provide 1 1/2" clear between each member.
13. The vapor retarder below all foundation areas shall be a minimum 10-mil polyethylene with all joints lapped 12 continuous and sealed. Drop vapor retarder down the sides of all beam trenches. DO NOT PLACE VAPOR RETARDER
ACROSS TRENCH BOTTOM .
14. Clay masonry brick is not acceptable for chairs.
Solid concrete brick may be used as chairs providing they are large enough and spaced to distribute construction traffic weights without damaging the Vapor Retarder.
15. Concrete shall not be placed on soils that have been disturbed by rainfall or seepage.
16. If bearing soils are softened by surface water intrusions during exposure or by desiccation, the unsuitable soils must be removed from the foundation excavation prior to placement of concrete.
17. In all instances minimum slab thickness shall be maintained. Coordinate slab finishes with architectural plans.
18. Backfill around perimeter to provide positive drainage away from the foundation.
19. All openings in the slab (for piping, drains, etc.)
shall be sealed.
DRILLED STRAIGHT SHAFT PIERS
1. Contractor shall coordinate with Geotechnical
Engineer for verification of piers bearing stratum at time of drilling.
2. Concrete shall develop a 28-day compressive strength of 3000 psi.
3. All reinforcing steel shall comply with the requirements of ASTM 615, Grade 60.
4. Center footing under beam unless dimensioned otherwise.
5. All reinforcing steel shall be continuous with splices lapped 48 bar diameters.
6. Pier shaft shall be drilled plumb along its total length.
(1" per 10'-0" max. tolerance)
7. Shafts shall penetrate into the dark grey unweathered lime stone three (3) feet or one shaft diameter, whichever is greater.
8. Soils Engineer shall approve pier depth, bearing material, pier size and reinforcement.
9. Bottom of ream to be clean and free of all loose materials and water.
10. Center steel cage in shaft with a minimum 3 levels of concrete Sled spacers (8-ft. maximum spacing) at a minimum of 3 evenly spaced radians. Support cage evenly on 3" concrete Bolsters.
11. Concrete Sled spacers and Bolsters shall be as manufactured by PIERESEARACH, 501 East Main
Street, Arlington, TX 76010, (800) 342-2409, Fax
(817) 275-2335.
12. Do not raise cage off of footing bottom during concrete placement.
13. Concrete and reinforcing in shafts shall be placed the same day as drilling.
14. Net allowable bearing pressure three feet into dark grey unweathered limestone is 30,000 psf.
15. Contractor shall include in bid documents the costs for casing if required (to be determined on job site by
Soils Engineer) and unit costs for greater and lesser depth of drilling.
| General Sheets |
| Cover Sheet |
| Civil Sheets |
| C-506 |
| C-507 |
| C-508 |
| C-509 |
| C-510 |
| Structural Sheets |
| S-001 |
| S-002 |
| S-101 |
| S-102 |
| S-103 |
| S-301 |
| S-302 |
| S-303 |
| S-304 |
| Architectural Sheets |
| AD101 |
| AD102 |
| AD111 |
| AD112 |
| AD201 |
| AD202 |
| AD203 |
| A-100 |
| A-101 |
| A-102 |
| A-103 |
| A-104 |
| A-111 |
| A-112 |
| A-120 |
| A-201 |
| A-202 |
| A-203 |
| A-301 |
| A-302 |
| A-303 |
| A-304 |
| A-305 |
| A-306 |
| A-307 |
| A-308 |
| A-309 |
| A-310 |
| A-321 |
| A-322 |
| A-401 |
| A-402 |
| A-403 |
| A-404 |
| A-405 |
| A-406 |
| A-501 |
| A-502 |
| A-503 |
| A-504 |
| A-505 |
| A-511 |
| A-512 |
| A-513 |
| A-514 |
| A-520 |
| A-521 |
| A-601 |
| A-602 |
| A-621 |
| A-622 |
| A-801 |
| A-901 |
| A-902 |
| I-101 |
| I-102 |
| I-531 |
| I-611 |
| I-901 |
| IF101 |
| IF102 |
| Mechanical Sheets |
| M-001 |
| MD-101 |
| MD-102 |
| MH-101 |
| MH-102 |
| M-103 |
| M-104 |
| M-105 |
| M-106 |
| M-501 |
| M-502 |
| M-503 |
| M-504 |
| M-505 |
| M-506 |
| M-507 |
| M-508 |
| M-509 |
| M-510 |
| M-511 |
| M-512 |
| M-601 |
| M-602 |
| M-603 |
| Plumbing Sheets |
| P-001 |
| PD-101 |
| PD-102 |
| PP-103 |
| PP-104 |
| PP-401 |
| PP-402 |
| PP-501 |
| PP-502 |
| PP-503 |
| E-001 |
| E-002 |
| ED-101 |
| ED-102 |
| E-101 |
| E-102 |
| E-111 |
| E-112 |
| E-113 |
| E-201 |
| E-202 |
| E-401 |
| E-501 |
| E-601 |
| E-602 |
| E-603 |
| E-604 |
| E-605 |
| E-606 |
| E-607 |
| E-608 |
| Telecomm Sheets |
| TN-000 |
| TN-001 |
| TND-101 |
| TND-102 |
| TN-011 |
| TN-101 |
| TN-102 |
| TN-201 |
| TN-202 |
| TN-401 |
| TN-402 |
| TN-501 |
| TN-601 |
| TN-602 |
| TN-603 |
| Fire Protection Sheets |
| LS101 |
| LS102 |
| FD101 |
| FP-001 |
| FP-101 |
| FP-102 |
| FP-103 |
| FP-501 |
| FP-502 |
| FP-801 |
| FP-802 |
| FA-001 |
| FA-101 |
| FA-102 |
| FA-501 |
| FA-601 |
File details come from the government source that posted it.